somfy · PDF file• motorized operations with: - sonesse® 40 - ls 40 ... som F y....
Transcript of somfy · PDF file• motorized operations with: - sonesse® 40 - ls 40 ... som F y....
somfy.com
CTS 40 guide• Cts 40 product data• Cts 40 components list• Cts 40 installation advice
Copyright © 2009 somfy sAs. All rights reserved - V1 - 06/2009
• this product is for interior use only.• the Cts 40 cannot be used inside sealed double-glazing.• the Cts 40 system fits only with tubes and headrails compatible
with accessories mentioned p. 4.• the selection of the correct cord, ladder braid and other acces-
sories is the responsibility of the blind manufacturer / assembler.• the complete blind system must be tested thoroughly by the blind manufacturer.• no tear or burr around the cord or ladder braid way.• Carry the blind closed and locked in its upper end limit.• Cts 40 is a somfy patented system.
A p p l i C A t i o n s
A s s e m B l i n gAdaptation to headrail Adaptable to headrails of at least 51 x 57 mm.
Adaptation to tube Cones specifically designed to fit the octagonal tube 40 x 0.6 mm.
U s i n g• motorized operations with: - sonesse® 40- ls 40- Altus 40- sonesse® 30
CTS 40• Universal cord lift and tilt system for interior blinds. • Fits perfectly with wooden Venetian blinds.• Driven by octagonal tube.• specifically designed for octagonal tubes 40 x 0.6 mm.• even cord winding on cone.• Composition: - 1 cone - 1 bearing
2no co
ntrac
tual p
ictur
es/dr
awing
s -
Cop
yrigh
t © 2
010
somf
y sAs
. All r
ights
rese
rved
- V1
- 04/2
010
VenetiAn BlinDs
RomAn BlinDs
CellUlAR BlinDs
BAlloon BlinDs
pleAteD BlinDs
Cone
Bearing
C T S 4 0 p R o D U C t D A t A
Bearing
Cone
C T S 4 0 p R o D U C t D A t A
3
CTS 40
no co
ntrac
tual p
ictur
es/dr
awing
s -
Cop
yrigh
t © 2
010
somf
y sAs
. All r
ights
rese
rved
- V1
- 04/2
010
t e C H n i C A l s p e C i F i C A t i o n s :
* Check component list for specificities
maximum load per cord
maximum length of cord which can be rolled
maximum revolutions
Working temperature (°C / °F)
Cord data
ladder data
number of tilting
number of cycles
Cord round braided, 100% polyester yarns, cord braiding: 16 ends Ø 1.4 mm +/- 0.1 mm with a core inside.
Cord treatment stabilized.
100% polyester
5,000
4 kg
5,5 m
35
-10 to +60°C (50° - 140°F)
10,000
25.7
+/-0
.2
8
40.7+/-0.3
40.7
+/-0
.3
104.6 maxi
patent pendingep 0 554 212Us 5,328,113Jp 05-13756
KR 10-0255434
20 ± 0.15
38+
0.05
+ 0.
30
All values are in mm
C T S 4 0 C o m p o n e n t s l i s t
4
*moQ: minimum order quantity**non exhaustive list
• Cone Cts 40• moQ*: 1 pc• Unit weight: 23 g• interface drawing 5055609A
Cts components
Ref.: 9162144
• Bearing Cts 40 for 51x57mm• moQ*: 1 pc • Unit weight: 23 g• interface drawing 5055609A
Ref.: 9162145
• plug-end for octagonal tube 40 x 0,6 mm• moQ*: 1 pc• Unit weight: 35 g• interface drawing 9137018A
Ref.: 9137018
• Crown• For octagonal tube 40 x 0.6 mm DepRAt • moQ*: 10 pcs• interface drawing 9132145A
Ref.: 9132145
• Wheel• For octagonal tube 40 x 0.6 mm DepRAt• moQ*: 10 pcs • interface drawing 9500344A
Ref.: 9500344
• Crown• For octagonal tube 40 x 0.6 mm imBAC• moQ*: 10 pcs • interface drawing 9147327A
tube adapters
Headrail accessories
Ref.: 9147327
• Wheel• For octagonal tube 40 x 0.6 mm imBAC • moQ*: 10 pcs• interface drawing 9147545A
Ref.: 9147545
Choose the components on the components list hereunder according to your application**.
no co
ntrac
tual p
ictur
es/dr
awing
s -
Copy
right
© 20
10 s
omfy
sAs.
All r
ights
rese
rved
- V1
- 04/2
010
• Cts 40 bracket for 51 x 57 headrail• moQ*: 1 pc • Unit weight: 19 g• interface drawing 9500736A
Ref.: 9500736
• Cts 40 bracket for nAniK headrail• moQ*: 1 pc• Unit weight: 19 g• interface drawing 9500644A
Ref.: 9500644
screw the motor bearing onto the motor.put the motor in down limit by supplying the motor and driving manually the crown adapter in the down direction.
setting buttons facing the bottom.
This part describes instructions related to authorised applications, compatible associated products and installation of the CTS 40 into the blind system. All instructions must be strictly followed whatever the specification of the system or processes. Otherwise, Somfy’s responsibility and guarantee are excluded.
C T S 4 0 i n s t A l l A t i o n A D V i C e
5 no co
ntrac
tual p
ictur
es/dr
awing
s -
Copy
right
© 20
10 s
omfy
sAs.
All r
ights
rese
rved
- V1
- 04/2
010
A D R i l l t H e H o l e s n e C e s s A R y F o R t H e m o t o R s W i t C H s C R e W s A n D p l U g e n D B e A R i n g s
B C U t t H e 4 0 m m o C t o g o n A l t U B e t o s i z e A n D D e B U R R l i g H t l y i t s e x t R e m i t i e s
C p U t t H e A D A p t A t o R , C R o W n A n D W H e e l o n t o t H e m o t o R
tube length is equal to the lenght of headrail minus 64 mm.(note: tube and end cap thickness are included)
Motor bracket holes
Limit switch access holes Ø 6mmWhen motorising the blind with a somfy diameter 40 motor progressive adjustment, drill holes to have access to the limit switch screws.
C T S 4 0 i n s t A l l A t i o n A D V i C e
6no co
ntrac
tual p
ictur
es/dr
awing
s -
Copy
right
© 20
10 s
omfy
sAs.
All r
ights
rese
rved
- V1
- 04/2
010
D p R e p A R e t H e l i F t i n g C o R D A n D t H e l A D D e R B R A i D
Lifting cordCut the cord at the blind height + 160 mm.tie a knot at the cord end.
e p U t i n p l A C e t H e B e A R i n g i n t o t H e H e A D R A i l
the bearing can be positionned in two ways: however we advise to put all the bearings in the same way.
Ladder braidmake a loop according to the slat width with the following recommendation:- During the rotation, the upper slat should never touch the headrail.- When the blind is completely retracted, the ladder loop has to be short enough not to escape the groove.
place the cord and the ladder in the bearing. take care the cord does not cross the ladder braid.note: in case on lift only application, there is no ladder operation.
C T S 4 0 i n s t A l l A t i o n A D V i C e
7 no co
ntrac
tual p
ictur
es/dr
awing
s - C
opyri
ght ©
201
0 so
mfy s
As. A
ll righ
ts re
serve
d - V
1 - 0
4/201
0
the ladder braids get into the cone groove, and then, slide the cones into the bearing.
position all the cords on the same side of the cone and slide the knot in the cone slots in order to attach them.
F t H R e A D t H e C o R D t H R o U g H t H e B e A R i n g s ( A n D t H e s t A C K o F s l A t s )
groove
ladder braid
take-up cord
g g e t t H e l A D D e R B R A i D t H R o U g H t H e B e A R i n g
H p U t t H e C o n e i n p l A C e
the position of the ladder braid depend on the dimen-sions of the slats.
C T S 4 0 i n s t A l l A t i o n A D V i C e
8no co
ntrac
tual p
ictur
es/dr
awing
s -
Copy
right
© 20
10 s
omfy
sAs.
All r
ights
rese
rved
- V1
- 04/2
010
i
J
s l i D e t H e t U B e i n t o t H e C o n e s
g e t t H e C o R D K n o t A t t H e B o t t o m o F t H e H e A D R A i l & i n s e R t t H e p l U g e n D
Secure the cords onto the cones during this operation. slide the tube into the cones and take care to well position the eventual external groove in the cone groove.
turn the tube one half a turn to get the cord knot at the bottom of the headrail.
insert the motor into the headrail and the tube.
insert the plug end.
the plug end side gets opposite the holes drilled for access to the limit switches
Rotate each cone and align for tube insertion
two studs to spot the cone groove
external groove of tube
plug end
motor
tube
Cone
C T S 4 0 i n s t A l l A t i o n A D V i C e
9
Attach the bottom bar and set the horizontality before adjusting the top and bottom end limits.
For better horizontality, we recomment to adjust the load bar with the blind at mid-height.
plug end bracket
K i n s e R t t H e p l U g e n D B R A C K e t i n t o t H e H e A D R A i l A n D o n t o t H e p l U g e n D
l F i n i s H t H e m o U n t i n g o F t H e B l i n D A n D t e s t i t
Fix and secure the plug end bracket to the headrail.
no co
ntrac
tual p
ictur
es/dr
awing
s - C
opyri
ght ©
201
0 so
mfy s
As. A
ll righ
ts re
serve
d - V
1 - 0
4/201
0
somfy.com
© so
mFy.
504
7844
. som
Fy s
As, c
apita
l 20.0
00.00
0 eu
ros,
RCs
Bonn
eville
303
970
230
. 06
/2009
ARgentinA: Somfy Argentina+54 (0) 1147 373 700
AUstRAliA: Somfy PTY LTD+61 (2) 2 9638 0744
Austria: Somfy GesmbH+43 (0) 662 62 53 08
Belgium: Somfy Belux+32 (0) 2 712 07 70
Brasil: Somfy Brasil STDA+55 11 (0) 3695 3585
Canada: Somfy ULC+1 (0) 905 564 6446
China: Somfy China Co. Ltd+86 21 (0) 6280 9660
Croatia: Somfy predstavnistvo +385 (0) 51502640
Cyprus: Somfy Middle East+357 (0) 25 34 55 40
Czech Republic: Somfy Spol s.r.o.+420 (0) 296 372 486-7
Denmark: Somfy AB Denmark+45 (0) 65325793
Finland: Somfy AB Finland+358 (0) 957 13 02 30
France: Somfy France+33 (0) 820 374 374
germany: Somfy GmbH+49 (0) 7472 930 0
greece: Somfy Hellas+30 (0) 210 614 67 68
Hong Kong: Somfy Co. Ltd+852 (0) 2523 6339
Hungary: Somfy Kft+36 (0) 1814 5120
india: Somfy India PVT Ltd+91 (0) 11 51 65 91 76
indonesia: Somfy Indonesia+62 (0) 21 719 3620israel: Sisa Home Automation Ltd
+972 (0) 3 952 55 54
iran: Somfy Iran +98 217 79 51 036
italy: Somfy Italia s.r.l+39 (0) 024 84 71 81
Japan: Somfy KK+81-45-481-6800
Jordan: Somfy Jordan +962 6 582 1615
Kingdom of saudi Arabia: Somfy Saudi+966 1 47 23 020
Kuwait: Somfy Kuwait +965 (0) 434 89 06
lebanon: cf. Cyprus Somfy Middle East+961 (0) 1 391 224
malaisia: Somfy Malaisia+60 (0)3 228 74743
mexico: Somfy Mexico SA de CV+52 (0) 55 4777 7770
morocco: Somfy Maroc+212 (0) 22 44 35 00
netherlands: Somfy BV+31 (0) 23 55 44 900
norway: Somfy Norway+47 (0) 41 57 66 39
poland: Somfy SP Z.O.O
+48 (0) 22 50 95 300
portugal: Somfy Portugal+351 (0) 229 396 840
Romania: Somfy SRL+40 (0) 368 444 081
Russia: Somfy LLC+7 (0) 495 360 47 72
serbia: Somfy predstavnistvo +381 (0) 25 84 15 10
singapore: Somfy PTE LTD+65 (0) 638 33 855
slovaquia: cf. Czech Republic Somfy Spol s.r.o.+421 (0) 337 718 638
spain: Somfy Espana SA+34 (0) 934 800 900
south Korea: Somfy JOO
+82 (0) 2 594 4331
sweden: Somfy AB+46 (0) 40 165900
switzerland: Somfy A.G.+41 (0) 44 838 40 30
taïwan: Somfy Taiwan+886 (0) 2 8509 8934
thailand: Somfy Bangkok Regional Office+66 (0) 2714 3170
tunisia: Somfy Tunisia +216 98 30 36 03
turkey: Somfy Turkey+90 (0) 216 651 30 15
UAe: Somfy Gulf+971 (0)4 88 32 808
United Kingdom: Somfy LTD+44 (0) 113 391 3030
United states: Somfy Systems Inc+1 (0) 609 395 1300