Solid state relay_catalog

29
CATALOG 2013-2014 Place your Order now! And get 20% OFF the price 20% OFF

Transcript of Solid state relay_catalog

Page 1: Solid state relay_catalog

CATALOG

2013-2014

Place yourOrder now!

And get

20% OFFthe price

20% OFF

Page 2: Solid state relay_catalog

100%SATICFACTION100%SATICFACTION

Why do you chooseour company?

Shanghai AOYI Electric Companylimtid owns two producing factorieswith 20 years production history.

It is dedicated to developing,producing and marketing Solid StateRelay,SCRPower Regulator,Ampereor Voltage Meter,Temperature ControlInstrument,etc.

We devote to be the best supplier ofproducts and services to our globalcustormers at the best price.

Look what you can buy?

Page 3: Solid state relay_catalog

OUR CUSTOMER IN THE WORLDOUR CUSTOMER IN THE WORLD

Our products fit Asia maket perfectly, for our productsare very cheap but high quality,especially in China ourproducts cover every province and city.

Our products fit Asia maket perfectly, for our productsare very cheap but high quality,especially in China ourproducts cover every province and city.

Some countries in Europe also began using our products,with top grade products and excellent service,we obtainaccordant appreciation from them

Some countries in Europe also began using our products,with top grade products and excellent service,we obtainaccordant appreciation from them

In South America we have hold a few marketingshare, and this will be more and more.In South America we have hold a few marketingshare, and this will be more and more.

Our products have been sold far to North America.We have wonn favorable comments from Americancustomers.

Our products have been sold far to North America.We have wonn favorable comments from Americancustomers.

We have already entered Africa market, and our prodcutsare very popular in Africa. We will help them to developthe economy.

We have already entered Africa market, and our prodcutsare very popular in Africa. We will help them to developthe economy.

CHILE, INSTRUMENTACION TÉCNICA LTDACHILOE 1142-B, SANTIAGO, F:02-25540140

Page 4: Solid state relay_catalog

SSRAC Solid State Relay

SSRAC Solid State Relay

Solid state relay is usually called SSR for short. It is a new type of nono-contact switching device

SSR is usually a four-terminal active device including two control terminals and two output

terminals, and input and output terminals adopts reliable isolation.

Solid state relay adopts flame resistant engineering plastic case, epoxy resin encapsulation,

screw thread educing terminal connection with high strength structure, impulse resistance,high

shock resistance performance, small driving current for input terminal and convenient

connection with computer teminal and digital control circuit.

01 02

Input signal can make computer terminal and digital logic circuit compatible.

Optical isolation between input and output loop, 4000VAC dielectric withstanding

voltage

LED indication for working state

Built-in RC absorption circuit

Dielectric insulating strengh: 50M> Ω

> <Action reponse time:ON 10mS OFF 10mS

SUMMARYSUMMARY

Basic Character of Solid State RelayBasic Character of Solid State Relay

1 2

34

24~380VAC

Solid State Relay

SSR-40DA 40A

INPUT

3~32VDC

~~

+_

R

IN DC3-32V

OUT ON OFF

New Design Conform to IP ProtectionNew Design Conform to IP Protection

Pretty cap-exterior match safe and high

quality requirement

High Voltage ThyristorHigh Voltage Thyristor

Core adopts:imported components,

endure high current and voltage

co

nsta

nt

cu

rren

tin

pu

tcirc

uit

zero

-cro

ss-ov

er

trigg

erin

glo

op

3-3

2V

DC

+3

-4

Wiring Connection SimpleWiring Connection Simple

Zero-crossing triggering, eliminates the

surge current completely

Load

24-380VAC

2

1

Manufacturing Technique

We select high quality SCR, DCB

ceramic substrate and SMT technics.

1. ON-OFF Mode:zero cross triggering and random triggering1. ON-OFF Mode:zero cross triggering and random triggering

Zero cross triggering can be used as “switch”,

Random triggering can be used to control shift phase pulse to adjust load voltage.

First, you should know classification of solid state relay,more details are as following:First, you should know classification of solid state relay,more details are as following:

2. Output Components:bidirectional SCR output(ordinary type) and anti-paralleledtwo single phase SCR(enhanced type):2. Output Components:bidirectional SCR output(ordinary type) and anti-paralleledtwo single phase SCR(enhanced type):

Ordinary type is used for low current module or resistive load.

Enhanced type is used for high current module or inductive load.

3. Mounting Type: PCB tapered plug type,rail type,bolt type3. Mounting Type: PCB tapered plug type,rail type,bolt type

Cooling way of PCB tapered plug type is air-cooling,need not to match radiator.

Rail type is cooled by air or radiator

Bolt type is cooled by radiator.

4. Output Voltage Grades:220VAC,380VAC,480VAC,660VAC4. Output Voltage Grades:220VAC,380VAC,480VAC,660VAC

220VAC voltage grades is used for 220VAC resistive load

380VAC voltage grades is used for 220VAC inductive load and 380VAC resistive load

480/660VAC voltage grades is used for 380VAC inductive load.

How to select SSR?How to select SSR?

1.Resistive Load: twice load rated current

2.AC Motor Load: 6-7 times motor rated current

3.AC Electromagnet,Intermediate Relay and Inductive Coil Load: 4 times load rated

current

4.Power Compensator Capacitor Load: 5 times load rated current

5.Transformer Load: 5 times transformer primary rated current

6.Special Inductive and Captive:you should enlarge current margin according to

practical experience

Second, you should know current of solid state relay,more details are as following:Second, you should know current of solid state relay,more details are as following:

How to protect SSR?How to protect SSR?

1.Proper radiator adapted to the working requirement of solid state relay should be

equipped, the allowance should be widened when the load radiating condition is not

so good.You must avoid load short circuit.

2.Over Current Protection:over current and short circuit are the main reasons for

permanent damage of internal SCR ,fast fuse and air switch is one of the methods for

over current protection, fuse is also available for small current.

3.Over Voltage Protection:you can parallel voltage dependent resistor,its thickness

decides the protective voltage value,generally,471/10D voltage dependent resistor

is suitable for 220V series SSR, 681/10D for 380V series SSR, 821/10D for 480V

Page 5: Solid state relay_catalog

1 2

34

24~380VAC

Solid State Relay

SSR-40AA 40A

INPUT

90~250VAC

~~

R

~ ~

SSRSingle Phase Solid State Relay

SSRSingle Phase Solid State Relay

03 04

Application

Solid state relay is widely used in automatization control fields such as petrochemical

equipment,food machine,packaging machine,textile machine,plastic machine,numerical

control lathe,entertainment facility and so on, which especailly for severe environment

full of corrosion,moisture,explosion-proof and dust-proof or places demanding frequent

switching.

Generally, our solid state relay are applied with temperature controller to control

temperature of some machine, and different solid state relay should correspond to

different output of temperature controller. The following wiring diagrams are for your

reference only,please carry on the revision according to the actual need.

1 2

34

24~380VAC

Solid State Relay

SSR-40DA 40A

INPUT

3~32VDC

~~

+_

R

LOADFUSE

Power AC24-380V

Attention

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMT-2000

220VAC

VoltagePulseOutput

Th

erm

oco

up

le

+

-

+

_

DC-AC Solid State RelayDC-AC Solid State RelayDC-AC Solid StateRelayDC-AC Solid StateRelay

LOADFUSE

Power AC24-380V

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMT-2000

220VAC

RelayOutput

Th

erm

oco

up

le

+

-

AC-AC Solid StateRelayAC-AC Solid StateRelay

1 2

34

24~380VAC

Solid State Relay

SSR-25VA 25A

500KΩ 1/4W

~~

R

~ ~

FUSE

LOAD

Manual Solid State Voltage RegulatorManual Solid State Voltage Regulator

Power AC24-380V

500K potentiometercontrol output%

1 2

34

24~380VAC

Solid State Relay

SSR-40DA-P 40A

INPUT

4~8VDC

~~

+_

R

LOAD

FUSE

Power AC24-380V

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMT-2000

220VAC

Th

erm

oco

up

le

+

-VoltagePulseOutput

L

N

Random Solid State Voltage RegulatorRandom Solid State Voltage Regulator

A1

4~32VDC

C2B2A2

C1B1

SSR3-40DAR

THREE PHASE

MADE IN HUANAN

SOLID STATE RELAY

40A

24~380VAC

+

-

Single Phase Solid State RelaySingle Phase Solid State Relay

Three Phase Solid State RelayThree Phase Solid State Relay

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMT-2000

VoltagePulseOutput

Th

erm

oco

up

le

+

-

+

_

ABC

N

A1

4~32VDC

C2B2A2

C1B1

SSR3-40DAR

THREE PHASE

MADE IN HUANAN

SOLID STATE RELAY

40A

24~380VAC

+

-

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMT-2000

VoltagePulseOutput

Th

erm

oco

up

le

+

-

+

_

ABC

N

A1

4~32VDC

C2B2A2

C1B1

SSR3-40DAR

THREE PHASE

MADE IN HUANAN

SOLID STATE RELAY

40A

24~380VAC

+

-

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMT-2000

VoltagePulseOutput

Th

erm

oco

up

le

+

-

+

_

ABC

N

Above is connection,load voltage is 380VAC,load must be three-phasebalanced. And only three phase high voltage enhanced solid state relay issuitable for this connection.

Above is Y connection,load votage is 220VAC,for three-phase unbalancedload,you should select NO.1 and the center must be zero line.

Page 6: Solid state relay_catalog

SSR

Switching

Output

Control input

Load Voltage

Monitoring

Zero cross

Bidirectional SCR

DC3-32V

24-380VAC

Output status

Input CircuitInput Circuit

Control Voltage

Control Current

DC3-32V

DC6-12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

5A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

1500VAC

100M 500VDCΩ@

-20~+70℃

PCB or Bolt Fixing

SSRSingle Phase AC Solid State Relay

SSR-380D05

Installation DemensionsInstallation Demensions

Special Functions PCB Solid State Relay

DC3-32V

DC6-12mA

24-380VAC

≤4mA

≤1.5V

≤10mS

1500VAC

100M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-210B

Miniture Size

Work Instructions LED /

Net Weight 56g 30g

Switching

Output

Zero cross

Bidirectional SCR

Application:

Have load over current or short-circuit

p ro tec t ion . I t p rov ides a re l iab le

guarantee for some machines which is

easy to short circuit.

Input CircuitInput Circuit

Control Voltage

Control Current

DC10-18V,DC20-28V

≤12mA

Output CircuitOutput Circuit

Load Voltage Range

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

PCB or Bolt Fixing

SSR-40DA-S

Installation DemensionsInstallation Demensions

Special Functions Over-current Protection

DC4-32V

DC6-12mA

24-380VAC

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-F-25/40DA

Built-in Fast Fuse

Work Instructions LED LED

Net Weight 157g 118g

Parameters Parameters

Load Current 10A,20A

Off-state Leakage Current ≤4mA

40A

≤4mA

Load Current 25A,40A

05 06

Single Phase AC Solid State Relay

Page 7: Solid state relay_catalog

07

SSR

Switching

Output

Load Current

Load Voltage

Monitoring

Zero cross

Bidirectional SCR

10A-90A

24-380VAC

Output status

Input CircuitInput Circuit

Control Voltage

Control Current

DC3-32V

DC6-12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR

SSR-(10-90)DA

Installation DemensionsInstallation Demensions

Special Functions /

DC4-32V

DC6-12mA

24-380VAC

≤4mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(10-90)DA

Imported SCR

Work Instructions LED LED

Net Weight 105g 110g

Parameters

Load Current 10A,15A,25A,40A,60A,75A,90A

Type-selection

Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SSR-10DA

SSR-15DA

SSR-25DA

SSR-40DA

SSR-60DA

220VAC

220VAC

220VAC

220VAC

220VAC

<5A

<7.5A

B-50 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

Installation Demensions 47(mm) 47(mm)

SSR-75DA 220VAC 80X80(mm)

SSR-90DA 220VAC 80X80(mm)

08

Switching

Output

Load Current

Load Voltage

Monitoring

Zero cross

Bidirectional SCR

10A-90A

90-480VAC

Output status

Input CircuitInput Circuit

Control Voltage

Control Current

DC3-32V

DC6-12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

90-480VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(10-90)DA-H

Installation DemensionsInstallation Demensions

Special Functions High Voltage SCR

DC4-32V

DC6-12mA

90-480VAC

≤4mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(10-90)DA-H

Imported High Voltage SCR

Work Instructions LED LED

Net Weight 105g 110g

Parameters

Load Current 10A,15A,25A,40A,60A,75A,90A

Installation Demensions 47(mm) 47(mm)

<12.5A

<20A

<30A

<37A

<41A

<1.1KW

<1.6KW

<2.7KW

<4.4KW

<6.6KW

<8.1KW

<9.0KW

B-50

A-50

A-50,C-55

C-55

C-55,E-50

C-55,E-50

Type-selection

Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SSR-10DA-H

SSR-15DA-H

SSR-25DA-H

SSR-40DA-H

SSR-60DA-H

220/380VAC <5A

<7.5A

B-50 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

SSR-75DA-H 80X80(mm)

SSR-90DA-H 80X80(mm)

<12.5A

<20A

<30A

<37A

<41A

<1.1KW

<1.6KW

<2.7KW

<4.4KW

<6.6KW

<8.1KW

<9.0KW

B-50

A-50

A-50,C-55

C-55

C-55,E-50

C-55,E-50

220/380VAC

220/380VAC

220/380VAC

220/380VAC

220/380VAC

220/380VAC

Single Phase AC Solid State RelaySingle Phase AC Solid State Relay

Page 8: Solid state relay_catalog

09

SSR

Switching

Output

Load Current

Load Voltage

Monitoring

Zero cross

Two anti-paralleled

s phase SCR

25A-120A

24-380VAC/90-660VAC

Output status

ingle

s

S

s

S

Input CircuitInput Circuit

Control Voltage

Control Current

DC4-32V

DC6-12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

15A,25A,40A,60A,75A,90A,120A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR

SSR-(15-120)DA

Installation DemensionsInstallation Demensions

Special Functions Enhanced SCR

DC4-32V

DC6-12mA

90-660VAC

≤4mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(15-120)DA-H

High Voltage Enhaced SCR

Work Instructions LED LED

Net Weight 120g 120g

Parameters

Load Current 15A,25A,40A,60A,75A,90A,120A

Type-selection

Mode:Load Voltage Using Current Using PowerReferenceRadiator

SSR-10DA:

SSR-25DA:

SSR-40DA:

SSR-60DA:

SSR-75DA:

220VAC

220VAC

220VAC

220VAC

220VAC

<6A

<15A

Installation Demensions 47(mm) 47(mm)

SSR-90DA: 220VAC

SSR-120DA: 220VAC

10

Switching

Output

Load Current

Control Voltage

Load Voltage

Monitoring

Zero cross

Bidirectional SCR

10A-90A

80-250VAC

90-480VAC

Output status

Input CircuitInput Circuit

Control Voltage

Control Current

AC80-250V

≤2mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(10-90)AA

Installation DemensionsInstallation Demensions

Special Functions High Voltage SCR

≤4mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(10-90)AA

Imported High Voltage SCR

Work Instructions LED LED

Net Weight 105g 110g

Parameters

Load Current 10A,15A,25A,40A,60A,75A,90A

Installation Demensions 47(mm) 47(mm)

<24A

<36A

<45A

<54A

<70A

<1.3KW

<3.3KW

<5.2KW

<7.9KW

<9.9KW

<11.8KW

<15.4KW

C-110

C-110,E-110

Type-selection

Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SSR-10AA

SSR-15AA

SSR-25AA

SSR-40AA

SSR-60AA

220VAC <5A

<7.5A

B-50 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

SSR-60AA 80X80(mm)

SSR-60AA 80X80(mm)

<12.5A

<20A

<30A

<37A

<41A

<1.1KW

<1.6KW

<2.7KW

<4.4KW

<6.6KW

<8.1KW

<9.0KW

B-50

A-50

A-50,C-55

C-55

C-55,E-50

C-55,E-50

220VAC

220VAC

220VAC

220VAC

220VAC

220VAC

Mode:Load Voltage

SSR-10DA-H:

SSR-25DA-H:

SSR-40DA-H:

SSR-60DA-H:

SSR-75DA-H:

220/380VAC

220/380VAC

220/380VAC

220/380VAC

220/380VAC

SSR-90DA-H: 220/380VAC

SSR-120DA-H: 220/380VAC

ReferenceFan

C-55,E-50

A-50

C-55

C-55,C-110

B-50 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

AC80-250V

≤2mA

24-380VAC

Single Phase AC Solid State Relay Single Phase AC Solid State Relay

Page 9: Solid state relay_catalog

11

SSR

Input CircuitInput Circuit

Control Voltage

Control Current

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

90-480VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR

SSR-(10-90)AA-H

Installation DemensionsInstallation Demensions

Special Functions High Voltage SCR

90-660VAC

≤4mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(15-120)AA-H

High Voltage Enhaced SCR

Work Instructions LED LED

Net Weight 105g 120g

Parameters

Load Current 15A,25A,40A,60A,75A,90A,120A

Type-selection

ModeUsingCurrent

UsingPower

ReferenceRadiator

Installation Demensions 47(mm) 47(mm)

12

Switching

Input

Output

Control Voltage

Load Voltage

Monitoring

Zero cross

One or two input

Two Output

4-32VAC

24-380VAC

Output status

Input CircuitInput Circuit

Control Voltage

Control Current

AC80-250V

DC12-32mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

10A,15A,25A,40A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR2-(10-40)DA

Installation DemensionsInstallation Demensions

Special Functions One Input, Two Output

≤4mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-(10-40)DA-2K

Two Input, Two Output

Work Instructions LED LED

Net Weight 270g 270g

Parameters

Load Current 10A,15A,25A,40A

Installation Demensions 70(mm) 70(mm)

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

SSR2-10DA/SSR2-10DA-2K 220VAC <5AX2

<6.5AX2

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<8AX2

<8AX2

<1.1KWX2

<1.4KWX2

<1.7KWX2

<1.7KWX2

220VAC

220VAC

220VAC

LoadVoltage

ReferenceFan

AC80-250V

DC12-32mA

24-380VAC

Switching

Output

Load Current

Control Voltage

Load Voltage

Monitoring

Zero cross

Bidirectional SCR/Two

anti-paralleled single phase SCR

10A-90A

80-250VAC

90-480VAC/ 90-660VAC

Output status

AC80-250V

≤2mA

AC80-250V

≤2mA

SSR-(10A-90A)AA-H

SSR-(15A-120A)AA-H

220/380VAC

220/380VAC

Single Phase AC Solid State RelaySingle Phase AC Solid State Relay

SSR2-15DA/SSR2-15DA-2K

SSR2-20DA/SSR2-20DA-2K

SSR2-40DA/SSR2-40DA-2K

Please refer Page 8,AA is identified as DA

Please refer Page 9,AA is identified as DA

Page 10: Solid state relay_catalog

13

SSR

Industry Solid State Relay

Switching

Output

Load Voltage

Monitoring

Withstand Voltage

Zero cross

Two anti-paralleled

Single phase SCR

24-440VAC

Output status

2500VAC

S

Input CircuitInput Circuit

Control Voltage

Control Current

DC3-32V

DC7-12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-440VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2500VAC

1000M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR

SSR-60DA

Installation DemensionsInstallation Demensions

Special Functions Very Good Overload Capacity

DC3-32V

DC7-12mA

24-440VAC

≤4mA

≤1.5V

≤10mS

2500VAC

1000M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-80/100/120DA

Work Instructions LED LED

Net Weight 120g 145g

Parameters

Load Current 10A,15A,25A,40A,60A,75A,90A

Installation Demensions 80(mm) 80(mm)

14

Single Phase AC Solid State RelaySingle Phase AC Solid State Relay

Very Good Overload Capacity

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

GYSSR-60DA 220/380VAC <36A

<48A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<60A

<72A

<7.9KW

<10.5KW

<13.2KW

<15.8KW

GYSSR-80DA

GYSSR-100DA

GYSSR-120DA

220/380VAC

220/380VAC

220/380VAC

Reference Radiator

L-150 for three sets

L-150 for three sets

L-150 for three sets

L-150 for three sets

Industry Solid State Relay

Switching

Output

Load Voltage

Monitoring

Withstand Voltage

Zero cross

Two anti-paralleled

Single phase SCR

24-440VAC

Output status

2500VAC

S

Input CircuitInput Circuit

Control Voltage

Control Current

DC3-32V

DC7-12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-440VAC

≤4mA

150A,200A,250A,300A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2500VAC

1000M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-150/200/250/300DA

Installation DemensionsInstallation Demensions

Special Functions Very Good Overload Capacity

DC3-32V

DC7-12mA

24-440VAC

≤4mA

≤1.5V

≤10mS

2500VAC

1000M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-350DA

Work Instructions LED LED

Net Weight 230g 560g

Parameters

Load Current 350A

Installation Demensions 80(mm) 92X38(mm)

Very Good Overload Capacity

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

GYSSR-150DA 220/380VAC <85A

<100A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<125A

<150A

<18.7KW

<22KW

<27.5KW

<33KW

GYSSR-200DA

GYSSR-250DA

GYSSR-300DA

220/380VAC

220/380VAC

220/380VAC

Reference Radiator

L-200 for three sets

L-200 for three sets

L-250 for three sets

L-300 for three sets

175-250VAC~~

80X80(mm)<175A <38.5KWGYSSR-350DA 220/380VAC L-400 for three sets

Page 11: Solid state relay_catalog

15

Switching

Output

Load Current

Load Voltage

Monitoring

Zero cross

10A-90A

24-380VAC/90-480VAC

Output status

Bidirectional SCR

Input CircuitInput Circuit

Control Voltage

Control Current

DC4-32V

DC12-32mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤10mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR

SSR3-(10-90)DA

Installation DemensionsInstallation Demensions

Special Functions /

DC4-32V

DC12-32mA

90-480VAC

≤10mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR3-(10-90)DA-H

High Voltage SCR

Work Instructions LED LED

Net Weight 260g 260g

Parameters

Load Current 10A,15A,25A,40A,60A,75A,90A

Type-selection

Mode Using Current Using PowerReferenceRadiator

SSR3-10DA/SSR3-10DA-H <5AX3

<12AX3

Installation Demensions 90X48(mm) 90X48(mm)

<20AX3

<30AX3

<37AX3

<41AX3

<1.1KWX3

<2.7KWX3

<4.4KWX3

<6.6KWX3

<8.1KWX3

<9KWX3 L-150

Load VoltageReference

Fan

C-110

G-80,D-120

C-110

E-110

G-80 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

Three Phase AC Solid State Relay

380VAC

SSR3-25DA/SSR3-25DA-H

SSR3-40DA/SSR3-40DA-H

SSR3-60DA/SSR3-60DA-H

SSR3-75DA/SSR3-75DA-H

SSR3-90DA/SSR3-90DA-H

380VAC

380VAC

380VAC

380VAC

380VAC

16

Switching

Output

Load Current

Load Voltage

Monitoring

Zero cross

10A-90A

24-380VAC/90-480VAC

Output status

Bidirectional SCR

SSRThree Phase AC Solid State Relay

Note:For SSR3-DA,the load adopts Y-connection, and the center of Y should be connected toneutralline. -H can

l or not.For SSR3-DA ,the load adopts Y-connection, and the center of Y be connected

to neutra line

Input CircuitInput Circuit

Control Voltage

Control Current

AC80-250V

≤12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤10mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR3-(10-90)AA

Installation DemensionsInstallation Demensions

Special Functions /

AC80-250V

≤12mA

90-480VAC

≤10mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR3-(10-90)AA-H

High Voltage SCR

Work Instructions LED LED

Net Weight 260g 260g

Parameters

Load Current 10A,15A,25A,40A,60A,75A,90A

Type-selection

Mode Using Current Using PowerReferenceRadiator

SSR3-10AA/SSR3-10AA-H <5AX3

<12AX3

Installation Demensions 90X48(mm) 90X48(mm)

<20AX3

<30AX3

<37AX3

<41AX3

<1.1KWX3

<2.7KWX3

<4.4KWX3

<6.6KWX3

<8.1KWX3

<9KWX3 L-150

Load VoltageReference

Fan

C-110

G-80,D-120

C-110

E-110

G-80 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

380VAC

SSR3-25AA/SSR3-25AA-H

SSR3-40AA/SSR3-40AA-H

SSR3-60AA/SSR3-60AA-H

SSR3-75AA/SSR3-75AA-H

SSR3-90AA/SSR3-90AA-H

380VAC

380VAC

380VAC

380VAC

380VAC

Note:For SSR3-AA,the load adopts Y-connection, and the center of Y should be connected toneutralline. A -H can

l or not.For SSR3- A ,the load adopts Y-connection, and the center of Y be connected

to neutra line

Page 12: Solid state relay_catalog

17

Switching

Output

Load Current

Applied for

Monitoring

Zero cross

10A-90A

Inductive Load

Output status

Two anti-paralleled

single phase SCRs

Input CircuitInput Circuit

Control Voltage

Control Current

DC4-32V

DC12-32mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤10mA

25A,40A,60A,75A,120A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR

SCR3-(25-120)DA

Installation DemensionsInstallation Demensions

Special Functions Enhanced SCR

DC4-32V

DC12-32mA

90-660VAC

≤10mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SCR3-(25-120)DA-H

High Voltage EnhancedSCR

Work Instructions LED LED

Net Weight 440g 440g

Parameters

Load Current 25A,40A,60A,75A,90A,120A

Type-selection

Mode Using Current Using PowerReferenceRadiator

SSR3-25DA/SSR3-25DA-H <15AX3

<24AX3

Installation Demensions 90X48(mm) 90X48(mm)

<36AX3

<45AX3

<54AX3

<70AX3

<5.7KWX3

<9.1KWX3

<13.6KWX3

<17.1KWX3

<20.5KWX3

<25.4KWX3

L-150

Load VoltageReference

Fan

C-110

G-80,D-120

C-110

E-110

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

Three Phase AC Solid State Relay

380VAC

SSR3-40DA/SSR3-40DA-H

SSR3-60DA/SSR3-60DA-H

SSR3-75DA/SSR3-75DA-H

SSR3-90DA/SSR3-90DA-H

SSR3-120DA/SSR3-120DA-H

380VAC

380VAC

380VAC

380VAC

380VAC

18

Switching

Output

Load Current

Load Voltage

Monitoring

Zero cross

10A-90A

24-380VAC/90-480VAC

Output status

Bidirectional SCR

SSRThree Phase AC Solid State Relay

Note:For SSR3-DA,the load adopts Y-connection or connection, and the center of Y shouldbe connected to neutralline. -H

can l or not.For SSR3-DA ,the load adopts Y-connection or connection, and

the center of Y be connectedto neutra line

△-△-

L-150

Type-selection

Mode Using Current Using PowerReferenceRadiator

SSR3-25AA/SSR3-25AA-H <15AX3

<24AX3

<36AX3

<45AX3

<54AX3

<70AX3

<5.7KWX3

<9.1KWX3

<13.6KWX3

<17.1KWX3

<20.5KWX3

<25.4KWX3

L-150

Load VoltageReference

Fan

C-110

G-80,D-120

C-110

E-110

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

380VAC

SSR3-40AA/SSR3-40AA-H

SSR3-60AA/SSR3-60AA-H

SSR3-75AA/SSR3-75AA-H

SSR3-90AA/SSR3-90AA-H

SSR3-120AA/SSR3-120AA-H

380VAC

380VAC

380VAC

380VAC

380VAC L-150

Note:For SSR3-AA,the load adopts Y-connection or connection, and the center of Y shouldbe connected to neutralline. -H

can l or not.For SSR3-AA ,the load adopts Y-connection or connection, and

the center of Y be connectedto neutra line

△-△-

Input CircuitInput Circuit

Control Voltage

Control Current

AC80-250V

≤12mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤10mA

25A,40A,60A,75A,120A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SCR3-(25-120)AA

Installation DemensionsInstallation Demensions

Special Functions Enhanced SCR

DC80-250V

≤12mA

90-660VAC

≤10mA

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SCR3-(25-120)AA-H

High Voltage Enhanced SCR

Work Instructions LED LED

Net Weight 440g 440g

Parameters

Load Current 25A,40A,60A,75A,90A,120A

Installation Demensions 90X48(mm) 90X48(mm)

Page 13: Solid state relay_catalog

SSRThree Phase AC Solid State Relay

SSRThree Phase AC Motor Reverse Module

Temperature Controller

Features

High Current, the rane of load current is wide, and with raditor and fan

Auto-protection for over temperature,if over 50 , the fan will be

started, and if over 70 ,the circuit will be cut

Input voltage range suitable for around the world

Control system, power device and auxiliary power integration

High precision, temperature controlled accurately

Technical DataTechnical Data

Rated Current

Load Voltage

Control Voltage

Control Current

Mounting Methods

90A,120A,150A,200A,250A,300A,350A,400A,500A,600A

380VAC

4-32VDC

DC20-95mA

Bolt Fixing

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

ZHSSR3-90DA 220VAC <7.5A

<12.5A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<20A

<37A

<1.6KW

<2.7KW

<4.4KW

<8.1KW

220VAC

220VAC

220VAC

Reference Radiator

G-80,D-120

80X80(mm)<40A <8.8KW220VAC

G-80,D-120

C-110,D-120

C-110

C-110,E-110

Features

Control voltage of 10-30VDC is wide range.

Two LED tube display motor rotating direction.

This module have a starting the electricity protection,no surge

impact,strong anti-interference ability.

This module have interlocking reverse control circuit to

effectively prevent reverse SCR conductting simultaneously.

Technical DataTechnical Data

Load Power

Load Voltage

Control Voltage

Control Current

On-off Time

Weight

2KW,3KW

380VAC

10-30VDC

10-30mA

≥300mS

520g

Connection ExampleConnection Example

FUSE

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

TSR-2KDA-H/ZF 380VAC Three phase<5.3A

80X80(mm)

80X80(mm)380VAC

Reference Radiator

G-80,D-120

ZHSSR3-(90-600)DA TSR3-2/3KDA-H/ZF

Positive Rotate Instruction Negative Rotate Instruction

G-80,D-120

+-

~~

+-

~~

+-

~~

70℃

70℃

50℃

220VAC

+

-

ABC

19 20

ZHSSR3-1200DA

ZHSSR3-150DA

ZHSSR3-200DA

ZHSSR3-250DA

80X80(mm)

80X80(mm)

<20A

<37A

<4.4KW

<8.1KW

220VAC

220VAC

80X80(mm)<40A <8.8KW220VAC

C-110,D-120

C-110

C-110,E-110

ZHSSR3-150DA

ZHSSR3-200DA

ZHSSR3-250DA

FUSE

FUSE

Rv

Rv

Rv

++-

Control Voltage10-30VDC

PositiveRotate

NegativeRotate

A

B

C

TSR-3KDA-H/ZFThree phase<7.9A

Three phase<2KW

Three phase<3KW

Page 14: Solid state relay_catalog

21

SSR

DC Motor Module

Input

Output

Mounting

Application

5 inputs or 8 outputs

5 outputs or 8 outputs

C45 rail

24V solenoid valve

Input CircuitInput Circuit

Control Voltage

Control Current

DC24V Com-anode or com-cathode

≤2mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

≤4mA

5AX5

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

C45 Rail

SSR

ST5-5DD

Special Functions 5 Inputs, 5 Outputs

ST8-5DD

Work Instructions LED

Net Weight 60g

Parameters

Load Current

Single Phase DC Motor ModuleSingle Phase DC Motor Module

8 Inputs, 8 Outputs

DC24V

22

DC Motor Module

Application

Widely used for textile machine, chemical

machinery, food machine and the other

occasion which need control on-off state or

stepless speed regulation for DC motor.

Input CircuitInput Circuit

Control Voltage

Control Current

DC3-32V

DC2-15mA

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

≤4mA

10A,30A,75A

≤1.5V

≤10mS

Insulation Resistance

Ambient Temperature

Mounting Methods

1500VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

SSR-10/30/75DD

Installation DemensionsInstallation Demensions

Special Functions Switch for DC Motor

DC0-5V

DC4-20mA

DC0-24V

1500VAC

100M 500VDCΩ@

-20~+70℃

Bolt Fixing

DTS-10/25/40DD

Work Instructions LED

Net Weight 105g 145g

Parameters

Load Current 10A,25A,40A

Installation Demensions 47(mm) 80(mm)

Speeding Regulator for DC Motor

DC5-60V,5-300VDC

Voltage Bias

Current Bias

/ DC12V

DTS-10/25/40A-24V DiagramDTS-10/25/40A-24V Diagram

/ ≤20mA

/

/

/

/

Vb voltagebias +5VDC

Red

Orange

Yellow

Green

Blue

4-20mA,0-5V

+

-

ph

ase

shift

trigg

er

circ

uit

3

4 1

Load

mains locking terminal

+

10K/2W Potentiometer+

-DC0-24V

0

1

2

3

4

5

(V)

VIN

VOUT

(V)12 24

DC24V Com-anode or com-cathode

≤2mA

≤4mA

5AX5

≤1.5V

≤10mS

2000VAC

500M 500VDCΩ@

-20~+70℃

C45 Rail

LED

80g

DC24V

Connection DiagramConnection Diagram

Page 15: Solid state relay_catalog

SSR

Manual Voltage Regulator

Output

Control Mode

Load Voltage

Bidirectional SCR

External Potentiometer

to manual adjust voltage

24-380VAC

S

Input CircuitInput Circuit

Control Mode 500K Potentiometer @220VΩ

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

PCB or Bolt Fixing

SSRSolid State Voltage Regulator

SSR-(10-90)VA

Installation DemensionsInstallation Demensions

Special Functions

24-380VAC

≤4mA

≤1.5V

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

Work Instructions /

Net Weight 105g 110g

Parameters

Load Current

23 24

Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SSR-10VA

SSR-15VA

SSR-25VA

SSR-40VA

SSR-60VA

220VAC

220VAC

220VAC

220VAC

220VAC

<5A

<7.5A

B-50 80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

SSR-75VA 220VAC 80X80(mm)

SSR-90VA 220VAC 80X80(mm)

<12.5A

<20A

<30A

<37A

<41A

<1.1KW

<1.6KW

<2.7KW

<4.4KW

<6.6KW

<8.1KW

<9.0KW

B-50

A-50

A-50,C-55

C-55

C-55,E-50

C-55,E-50

10A,15A,25A,40A,60A,75A,90A

/

/ /

SSR-(10-90)VA

/ Imported SCR

Input CircuitInput Circuit

Control Mode 500K @220V 1M @380VΩ Ω

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

90-480VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

PCB or Bolt Fixing

SSR-(10-90)VA-H

Special Functions

90-480VAC

≤4mA

≤1.5V

2000VAC

500M 500VDCΩ@

-20~+70℃

Bolt Fixing

Work Instructions /

Net Weight 105g 120g

Parameters

Load Current 15A,25A,40A,60A,75A,120A

/

/ /

SSR-(10-90)VA-H

High Voltage Enhanced SCREnhanced SCR

Manual Voltage Regulator

Output

Control Mode

Load Voltage

Two anti-paralleled

single phase SCR

External Potentiometer

to manual adjust voltage

90-480VAC

S

S

S

S

500K Potentiometer @220VΩ 500K @220V 1M @380VΩ Ω

Type-selection

ModeUsing

CurrentUsingPower

ReferenceRadiator

LoadVoltage

ReferenceFan

SSR-(10A-90A)VA-H

SSR-(15A-120A)VA-H

220/380VAC

220/380VAC

Solid State Voltage Regulator

Please refer Page 8,AA is identified as DA

Please refer Page 9,AA is identified as DA

Page 16: Solid state relay_catalog

Output

Control Mode

Load Voltage

Manual Voltage Regulator Board

Bidirectional SCR

Built-in potentiometer

to manual adjust voltage

24-250VAC

S

Input CircuitInput Circuit

Control Mode Potentiometer:500K 2WΩ/

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-250VAC

≤4mA

16A

≤1.5V

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

SSR

SSR-16VA-A

Output Voltage WaveformOutput Voltage Waveform

Special Functions

24-250VAC

≤4mA

≤1.5V

2000VAC

500M 500VDCΩ@

-20~+70℃

Work Instructions /

Net Weight 72g 72g

Parameters

Load Current

25

16A

/

/ /

SSR-16VA-B

Output Voltage is 0V once startupOutput Voltage is 0V once startup Output Voltage is 24V once startupOutput Voltage is 24V once startup

Potentiometer:500K 2WΩ/

0

44

88

132

176

220

(V)

VOUT

VIN

(V)500KΩ250KΩ

0

44

88

132

176

220

(V)

VOUT

VIN

(V)500KΩ250KΩ

Note:These two products is a voltage regulator board plus upper panel, you can

customize upper panel according to your preference.

Manual Voltage Regulator

Integrated design,small size, simple intallation and

wiring connection.

It widely used for room lighting dimming, environment

temperature control, electrical switchgear cubicle and

the other automation control fields.

Input CircuitInput Circuit

Control Mode Potentiometer:500K 2WΩ/

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

On-off Time

Dielectric Strength

General DataGeneral Data

24-380VAC

≤4mA

10A,15A

≤1.5V

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

SSR

SSR-10/15VA

Installation DemensionsInstallation Demensions

Special Functions

24-380VAC

≤4mA

≤1.5V

2000VAC

500M 500VDCΩ@

-20~+70℃

Work Instructions /

Net Weight 125g 50g

Parameters

Load Current

26

15A

/

/ /

SSR-15VA

Integrated DesignIntegrated Design Room Lighting DimmingRoom Lighting Dimming

Potentiometer:500K 2WΩ/

Note:Manual voltage regulator for room lighting dimming is a voltage regulator board

plus upper panel, you can customize upper panel according to your preference.

Suken Mounting Suken Mounting Suken Mounting Suken Mounting

Single Phase AC Solid State RelaySingle Phase AC Solid State Relay

Solid State Voltage Regulator

Single Phase AC Solid State RelaySingle Phase AC Solid State Relay

Solid State Voltage Regulator

Page 17: Solid state relay_catalog

Random Solid State Relay

External pulse signal, this module applied with our patented products

ZKG-I and DPC-I can be used for temperature control of forming

machine or other resistive load.We have hold very big marketing share

in China and the other nation, and will be more and more.

Input CircuitInput Circuit

Control Mode Temperature controller,voltage regulator

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

Dielectric Strength

General DataGeneral Data

175-250VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

SSR

SSR-(10-90)DV

Output Voltage WaveformOutput Voltage Waveform

Special Functions

Net Weight 105g

Parameters

Load Current

27

Very Good Stabilizing Voltage FunctionVery Good Stabilizing Voltage Function

Suken Mounting

Solid State Voltage Regulator

Random Solid State Relay

Rapid response,when the effective control signal is applied across

input, the load of SSR-DA-P will be conducted at once.SSR-DA-P can

control shift phase pulse to adjust load voltage convinently, which be

used for temperature regulation,adjusting luminance and the other

resistive load or inductive load.

Input CircuitInput Circuit

Control Mode Temperature controller,voltage regulator

Output CircuitOutput Circuit

Load Voltage Range

Off-state Leakage Current

On-state Voltage

Dielectric Strength

General DataGeneral Data

175-250VAC

≤4mA

10A,15A,25A,40A,60A,75A,90A

≤1.5V

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

SSR

SSR-25DV

Output Voltage WaveformOutput Voltage Waveform

Special Functions

Net Weight 105g

Parameters

Load Current

28

Very Good Stabilizing Voltage FunctionVery Good Stabilizing Voltage Function

Suken Mounting

Solid State Voltage Regulator

PV

SV

SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR

P

ZKG-I

1 2

34

24~380VAC

Solid State Relay

SSR-25DV 25A

INPUT

~~

T1G

R

� �

G T N L

LOAD

FUSE

Power AC220V

L

N

1 2

34

24~380VAC

Solid State Relay

SSR-40DA-P 40A

INPUT

4~8VDC

~~

+_

R

LOAD

FUSE

Power AC24-380V

SSR-DA-P Series(Temperature controller control output%)SSR-DA-P Series(Temperature controller control output%)

SET

PV

SV

ALM1 ALM2ONAT OFF

《《

RXMT-2000

220VAC

Th

erm

oco

up

le

+

-VoltagePulseOutput

L

N

Page 18: Solid state relay_catalog

SSR

29

SSRSingle Phase SCR Voltage Regulator

Application

Output Voltage:

Forming machine,lamp,temperature

Regulation,industrial furnace,oven,

electrical switchgear cubicle and the

other automation control fields.

0-220V/220-0V

s

Input CircuitInput Circuit

Control Mode 0-5V,4-20mA,10K/2W potentiometer

Output CircuitOutput Circuit

Load Voltage Range

Dielectric Strength

General DataGeneral Data

A:220-0VAC B:0-220VAC

10A,15A,25A,40A

Insulation Resistance

Ambient Temperature

Mounting Methods

2000VAC

500M 500VDCΩ@

-20~+70℃

SSR-10/25/40LA-A/B

Output Voltage WaveformOutput Voltage Waveform

Special Functions

0-220VAC

2000VAC

500M 500VDCΩ@

-20~+70℃

Net Weight 115g 115g

Parameters

Load Current

Bolt Fixing

10A,15A,25A,40A

4-20mA

4-20mA

Bolt Fixing

30

Work Instructions / /

SSR-10/25/40LA

0-5V,4-20mA,10K/2W potentiometer0-5V,4-20mA,10K/2W potentiometer

Voltage Bias

Current Bias

A:DC5V B:DC12V

≤30mADC

/

/

Off-state Leakage Current

On-state Voltage

≤4mA

≤1.5V

/

/

Single Phase SCR Voltage Regulator

Summary

GridsVoltage

OutputWide

Pulse

OutputVoltage Uoff 2.5V Uon 5V

0.5

1

Uoff:0.7 0.2V Uon:4.3 0.2V

Ucon

Pulse Duty Factor

Single phase SCR voltage regulator includes synchronous phase detecting circuit,

sawtooth wave circuit, input control regulating circuit, reference circuit, phase shift

compare circuit,output trigger circuit, and stabilized voltage supply which provides

power to these circuits , etc. When control voltage is changed from low to high, in the

inner of this module will generate triggering pulse between 180 and 0 relative to

network voltage, after photoelectric isolation,then A and G output terminal can trigger

corresponding SCR to realize shift phase voltage regulation.

Ultra small and thin,adopt SMT technics.

screw hold-down connection and bolt fixing mounting,very easy to use.

Adopt photoelectric isolation, you can manually control voltage by potentiometer or

automatically by voltage signal and current signal.

The trigger adopts single wide pulse trigger mode, which is suitable for inductive or

resistive load.

LED indication for working state

Built-in RC absorption circuit

Features

Waveform DiagramWaveform Diagram

About working waveform of single phase SCR voltage regualtor,we take 0-5V input as an

example.When control voltage is changed from 0V to 5V, the module will generate

triggering pulse between 180 and 0 relative to network voltage, then this triggering

pulse make us get different output voltage waveform.

0-Uoff is shutoff area,there is no ouput in main circuit.

Uoff-Uon:basic linear area,load voltage increased linearly with control signal.

Uon-5V:fully conducting state, load voltage is grids voltage.

Page 19: Solid state relay_catalog

SSRSingle Phase SCR Voltage Regulator

SSRSingle Phase SCR Voltage Regulator

Temperature Controller

L

N220VAC

Features

Very-hot sale Products,low cost but high qualtiy

The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world

Modularized, high voltage resistant, more safe and reliable

Control system, power device and auxiliary power integration

High precision, temperature controlled accurately

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

15A,25A,40A,75A,90A

50Hz/60Hz

Single phase 175-265VAC

Phase Output

4-20mA,0-5V,0-10V,2-10K Potentiometer@0-5VΩ

Less than 45 ,humidity less than 90%RH℃

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

4-20mA,0-5VD,0-10VDC

Temperature sensor

Single PhaseSingle Phase

SCR Voltage RegulatorSCR Voltage RegulatorSCR-75LA

4-20mA INPUT

0-5V INPUT0-5V INPUT

IN 220VACIN 220VAC

OUT

175-265VAC

+5V+5V CON COM

FUSE

LOAD

31

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

SCR-15LA 220VAC <7.5A

<12.5A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<20A

<37A

<1.6KW

<2.7KW

<4.4KW

<8.1KW

SCR-25LA

SCR-40LA

SCR-75LA

220VAC

220VAC

220VAC

Reference Radiator

G-80,D-120

80X80(mm)<40A <8.8KWSCR-90LA 220VAC

G-80,D-120

C-110,D-120

C-110

C-110,E-110

Temperature Controller

L

N220VAC

Features

Enhanced Voltage Regulator, especially for inductive load.

The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world

Modularized, high voltage resistant, more safe and reliable

Welding technique, good quality and long service life

High precision, temperature controlled accurately

Vacuum

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

25A,40A,75A,90A 120A,50Hz/60Hz

Single phase 175-265VAC

Phase Output

4-20mA,0-5V,0-10V

Less than 45 ,humidity less than 90%RH℃

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

4-20mA0-5VD0-10VDC

4-20mA0-5VD0-10VDC

Temperature Sensor

FUSE

LOAD

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

SCR-25LA-II 220VAC <15A

<24A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<45A

<52A

<3.3KW

<5.2KW

<9.9KW

<11.4KW

SCR-40LA-II

SCR-75LA-II

SCR-90LA-II

220VAC

220VAC

220VAC

Reference Radiator

G-80,D-120

80X80(mm)<60A <13.2KWSCR-120LA-II 220VAC

C-110

C-110,E-110

SCR-(15-90)LA(Active) SCR-(25-120)LA-II

~ ~

~ ~

INPUTSingle PhaseSCR Voltage RegulatorSingle PhaseSCR Voltage Regulator

SCR-75LA-II

L N

INPUT

OUTPUT

Power work instruction Load work instruction

32

C-110,D-120

L-150,E-110

-+

Page 20: Solid state relay_catalog

SSRSingle Phase SCR Voltage Regulator

SSRSingle Phase SCR Voltage Regulator

33

Temperature Controller

L

N220VAC

Features

Heavy current and weak current is partially completely separated,control safety

High voltage and high current resistance

Modularized, high voltage resistant, more safe and reliable

Welding technique, good quality and long service life

High precision, temperature controlled accurately

Vacuum

The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

25A,40A,75A,90A 120A,50Hz/60Hz

Single phase 175-265VAC

Phase Output

4-20mA,0-5V,0-10V

Less than 45 ,humidity less than 90%RH℃

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

4-20mA0-5VD0-10VDC

4-20mA0-5VD0-10VDC

Temperature Sensor

FUSE

LOAD

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

SCR-15LA-WY 220VAC <7.5A

<12.5A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<20A

<37A

<1.6KW

<2.7KW

<4.4KW

<8.1KW

SCR-25LA-WY

SCR-40LA-WY

SCR-75LA-WY

220VAC

220VAC

220VAC

Reference Radiator

G-80,D-120

80X80(mm)<40A <8.8KWSCR-90LA-WY 220VAC

G-80,D-120

C-110,D-120

C-110

C-110,E-110

SCR-(25-120)LA-WY

~ ~

~ ~

-

+

INPUTSingle PhaseSCR Voltage RegulatorSingle PhaseSCR Voltage Regulator

SCR-75LA-WY

L N

INPUT

OUTPUT

Power work instruction Load work instruction

34

Features

High voltage and enhanced voltage regulator, can resist 305-456VAC

The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world

Modularized, high voltage resistant, more safe and reliable

Welding technique, good quality and long service life

High precision, temperature controlled accurately

Vacuum

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

25A,40A,75A,90A,120A

50Hz/60Hz

Single phase 305-456VAC

Phase Output

4-20mA,0-5V,0-10V

Less than 45 ,humidity less than 90%RH℃

Connection ExampleConnection Example

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

SCR-15LA-H 380VAC <7.5A

<12.5A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<20A

<37A

<1.6KW

<2.7KW

<4.4KW

<8.1KW

SCR-25LA-H

SCR-40LA-H

SCR-75LA-H

380VAC

380VAC

380VAC

Reference Radiator

G-80,D-120

80X80(mm)<40A <8.8KWSCR-90LA-H 380VAC

G-80,D-120

C-110,D-120

C-110

C-110,E-110

SCR-(25-120)LA-II

Temperature Controller

L

L380VAC

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

4-20mA0-5VD0-10VDC

4-20mA0-5VD0-10VDC

Temperature Sensor

FUSE

LOAD

~ ~

~ ~

-

+

INPUTSingle PhaseSCR Voltage RegulatorSingle PhaseSCR Voltage Regulator

SCR-75LA-II

L N

INPUT

OUTPUT

Power work instruction Load work instruction

-+

-+

Page 21: Solid state relay_catalog

35

Features

Manually or automatically generate pulse DC voltage which can be

stepless controlled,adjustable range is wide,output precision is high.

Full isolated design,dielectric withstanding voltage is over 2000VAC

This module adopts SMT technics and DCB ceramic substrate,few

peripheral connection.

Application:electroplating,electrowelding,DC motor,and so on.

Technical DataTechnical Data

Load Current

Load Voltage

Control Voltage

Output Mode

Work Instructions

Weight

25A,40A,75A,90A,120A

175-265VAC

DC:0-5V,4-20mA,10k 2W potentiometerΩ/

Phase Output

Red Led: power supply Green Led:output voltage variation

440g

Connection ExampleConnection Example

Type-selection

Mode Load Voltage Using Current Using Power Reference Fan

SCR-15LA-ZL 220VAC <9A

<15A

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

<24A

<45A

<1.9KW

<3.3KW

<5.2KW

<9.9KW

Reference Radiator

G-80,D-120

80X80(mm)<52A <11.4KW

G-80,D-120

C-110,D-120

C-110

C-110,E-110

SCR-(25-120)LA-ZLI

L

N220VAC

FUSE

LOAD

Power work instruction Load work instruction

~ ~

~~

Voltage RegulatingRectifier ModuleVoltage RegulatingRectifier Module

SCR-40LA-ZL

+ -

+5

VC

ON

CO

M

+

-0-5V,4-20mA

SCR-25LA-ZL

SCR-40LA-ZL

SCR-75LA-ZL

SCR-90LA-ZL

80X80(mm)<60A <13.2KW L-150,E-110SCR-120LA-ZL

220VAC

220VAC

220VAC

220VAC

220VAC

SSRSingle Phase SCR Voltage Regulator

SSRSingle Phase SCR Voltage Regulator

36

Features

Protective cover to prevent electrical shock hazard.

The radiator and fan make sure a very nice heat emission.

High voltage and high current resistant.

Modularized, high voltage resistant, more safe and reliable.

Control system, power device and auxiliary power integration.

High precision, temperature controlled accurately.

Technical DataTechnical Data

Rated Current

Rated Voltage

Operation Frequency

Output Mode

25A,40A,75A

Single Phase 220VAC

50/60Hz

Phase Output

Connection ExampleConnection Example

AYSCR-(25-75)LA-DX

Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10K

potentiometer, control signal should select 0-5VDC

Ω

FUFU

NBF

Wiring Instructionof Control Circuit

220VACNL

+ -M

+ -M

External Signal Input

4-20mADC0-5VDC0-10V+ -

NBF

Uoff 10mA Uon 20mA

0.5

1

Uoff:4mA 0.5mA

Adjustable Area:Uoff-Uon

Uon:18-20mA

+

Ucon

Pulse Duty Factor

4mA

1.The main circuit adopts single phase 220VAC input.

2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall

not be locked tightly, or SCR will be burned by terminal heating.

3.During the use of the module, you need to match proper radiator, and heat conducting silicon

grease should be coated between radiator and SCR backboard. If the module power is very big,

please consider wind or water cooling.

4.Please use semi-conductive fast fuse for load over current.

5.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to

maximum output. The adjustable area is about 4.5-18mA, the closed area is 4-4.5mA, the wide-

open area is 18-20mA.

D

D

D

D

D

D

D

D

D

D

Page 22: Solid state relay_catalog

SSRSingle Phase SCR Voltage Regulator

38

Features

Protective cover to prevent electrical shock hazard.

The radiator and fan make sure a very nice heat emission.

Modularized, high voltage resistant, more safe and reliable.

Control system, power device and auxiliary power integration

built in fast fuse for over current and short-circuit protection

High voltage and high current resistant.

Technical DataTechnical Data

Rated Current

Rated Voltage

Operation Frequency

Output Mode

200A,250A,300A

Single Phase 220VAC

50/60Hz

Phase Output

Connection ExampleConnection Example

FUSCR-(25-75)LA-DX

Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10K

potentiometer, control signal should select 0-5VDC

Ω

FUFU

NBF

Wiring Instructionof Control Circuit

220VACNL

+ -M

+ -M

External Signal Input

4-20mADC0-5VDC0-10V+ -

NBF

Uoff 10mA Uon 20mA

0.5

1

Uoff:4mA 0.5mA

Adjustable Area:Uoff-Uon

Uon:18-20mA

+

Ucon

Pulse Duty Factor

4mA

1.The main circuit adopts single phase 220VAC input. Auxiliary power must be synchronous with

main power.

2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall

not be locked tightly, or SCR will be burned by terminal heating.

3.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to

maximum. The adjustable area is about 4.5-18mA, the shutoff area is 4-4.5mA and the fully

conducting area is 18-20mA.

4.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was

blown, the yellow LED was showing, right now please check the load circuit short or not or partial

discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse

of the same rating. Please never hop up the fuse ampere.

m

m

m

m

m

m

m

m

m

m

m

m

m

m

SSRSingle Phase SCR Voltage Regulator

37

Features

Protective cover to prevent electrical shock hazard.

The radiator and fan make sure a very nice heat emission.

Modularized, high voltage resistant, more safe and reliable.

Control system, power device and auxiliary power integration

High precision, temperature controlled accurately

High voltage and high current resistant.

Technical DataTechnical Data

Rated Current

Rated Voltage

Operation Frequency

Output Mode

90A,120A,150A

Single Phase 220VAC

50/60Hz

Phase Output

Connection ExampleConnection Example

HNSCR-(90-150)LA-DX

Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10K

potentiometer, control signal should select 0-5VDC

Ω

FUFU

NBF

Wiring Instructionof Control Circuit

220VACNL

+ -M

+ -M

External Signal Input

4-20mADC0-5VDC0-10V+ -

NBF

Uoff 10mA Uon 20mA

0.5

1

Uoff:4mA 0.5mA

Adjustable Area:Uoff-Uon

Uon:18-20mA

+

Ucon

Pulse Duty Factor

4mA

1.The main circuit adopts single phase 220VAC input.

2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall

not be locked tightly, or SCR will be burned by terminal heating.

3.During the use of the module, you need to match proper radiator, and heat conducting silicon

grease should be coated between radiator and SCR backboard. If the module power is very big,

please consider wind or water cooling.

4.Please use semi-conductive fast fuse for load over current.

5.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to

maximum output. The adjustable area is about 4.5-18mA, the closed area is 4-4.5mA, the wide-

open area is 18-20mA.

D

D

D

D

D

D

D

D

D

D

Page 23: Solid state relay_catalog

SSRSingle Phase SCR Voltage Regulator

40

SSRSingle Phase SCR Voltage Regulator

39

Patented Products for Forming Machine, Blowing Machine,Sheet Machine or OtherResistive Loads

Summary

Features

Our products based on single-chip computer as the core are designed to adjust load

voltage continuously by phase-shift trigger. Due to the use of deep voltage negative

feedback, our products have exceptional stabilized voltage property, well linearity

control function, and can minimize the effects of electric network fluctuation.

Our products have hold a most marketing share in China and the other nation, and will

become more and more.

Stabilized voltage property, well linearity control function, can minimize the effects

of electric network fluctuation.

Small, light, clear reading and low cost

Have high accuracy, good shock-resistant, good reliability.

Respond quickly to change in set voltage.

Have pushbutton switches which are operationally simple and reliable.

Important SpecificationsImportant Specifications

Adjustment Range

Working Voltage

Control Output Mode

0-220VAC

AC220V 50Hz(the other voltage can be customized)

Control SSR-DV module

Control one bidirectional SCR

Control one SKKT or two anti-paralleled single phase SCR

Installing Mode Panel type

Environment Conditons Maximum relative humidity 85%, Temperature 0-50℃

Connection DiagramConnection Diagram

PV

SV

SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR

P

1 2

34

24~380VAC

Solid State Relay

SSR-25DV 25A

INPUT

~~

T1G

R

� �

G T1 N L

LOAD

FUSE

Power AC220V

L

N

PV

SV

SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR

P

G T1 N L

LOAD

FUSE

Power AC220V

L

N

PV

SV

SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR

P

N L

LOAD

FUSE

Power AC220V

L

N

K2

G2

K1

G1

PV

SV

SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR

P

N L

LOAD

FUSE

Power AC220V

L

N

K2

G2

K1

G1

Fig.1 Fig.2

Fig.3 Fig.4

Safty NoticeSafty Notice

1.Please connect wire between output, feedback, power, ground wire and load according to

above Fig. The phase of load must correspond with power of voltage regulator (i.e.

synchronism), or it will lead to damage of voltage regulator.

2.Press up arrow or down arrow from the panel until required voltage (i.e. “SV” value), then you

will find it is synchronous changing between “SV” and “PV” value.

3.If you press “P” key at any time, our SCR voltage regulator will stop output untill you press “P”

key again.

4.Fig.5 and Fig.6 is integrated output,it is very convinient.But Fig.6 have full power output

function

SV Value

PV Value

V

Electrify Waveform

SV

PV

Operating Waveform

220V0V

220V

110V

110V

Fig.5 Fig.6

Page 24: Solid state relay_catalog

SSRSingle Phase SCR Voltage Regulator

42

SSRSingle Phase SCR Voltage Regulator

41

Product Selection TableProduct Selection Table

Appearance Type

ZKG-I

DimensionsOpening

SizeLoad Power Control Type

ConnectionDiagram

48x48x90 45x45 Any powerwill do

ControlSSR-DVModule

Fig.1

ZKG-IIB 48x48x107 45x45 Any powerwill do

Control abidirectionalSCR

Fig.2

ZKG-IIIB 48x48x107 45x45 Any powerwill do

Control twoanti-paralleledsingle phaseSCR or a SKKT

Fig.3 Fig.4

ZKG-IIA 48x48x75 45x45 Any powerwill do

Fig.2

ZKG-IIIA 48x48x75 45x45 Any powerwill do

Control twoanti-paralleledsingle phaseSCR or a SKKT

ZKD-IIA 72x72x120 67x67 Any powerwill do

Control abidirectionalSCR

Control abidirectionalSCR

Product Selection TableProduct Selection Table

Appearance Type

ZKD-IIIA

DimensionsOpening

SizeLoad Power Control Type

ConnectionDiagram

72x72x120 67x67 Any powerwill do

ZKG-5 48x48x110 45x45Must not belarger 500W

Intergrationcontrol loaddirectlly,butSCR can notbe split

Fig.5

ZKG-62 48x48x112 45x45

ZKG-64

DVC-4 48x48x75 45x45 Fig.6

ZKC-36 280x160x65 151x199.5 Any powerwill do

Fig.1Control 36 waySSR-DV

Fig.3 Fig.4

Fig.2

Must not belarger 500W

Fig.5

48x48x112 45x45Must not belarger 500W

Fig.5

Intergrationcontrol loaddirectlly,butSCR can besplit

Intergrationcontrol loaddirectlly,butSCR can besplit

Must not belarger 1000W

Intergrationcontrol loaddirectlly,andhave full poweroutput function

Page 25: Solid state relay_catalog

SSRDigital Power Control Series

44

Features

Intergrated output,very convinient,and buitl-in radiator,but the

maximum power is 800W

Be fit for forming machine, blowing machine and the other resistive load

There is stabilized voltage output

After start-up you can set the time of full power output

Auto memory function, the stored program will never get lost

External full-power manual control, you can warm up quickly

Technical DataTechnical Data

Working Voltage

Adjustment Range

Phase-shifting Angle

Output Mode

150-220VAC 50/60Hz

0-99%

0-160。

Phase Output

Connection ExampleConnection Example

DPC-II-M

Use Environment Less than 45 ,humidity less than 85%RH℃

Remark:

1.DPC-II-M have three states,non power output(OF),full power output(HP) and set percentage

power output . These three work state have auto memory function after electrifying the meter and

can be circularly changed by “P” key.

2.“S1” switch is external manual switch of full power output control. When “SI” is closed, DPC-III-M

output full power, except “OF” and “HP” state. This function can be optional according to practical

application.

3.When multi DPC-II-M were used, DPC-II-M in the same phase can share one external control

switch of full power output.

Overall Dimensions

Opening Size

52x52x35(mm)

46x45(mm)

1 2

34

24~380VAC

Solid State Relay

SSR-25DV 25A

INPUT

~~

T1G

R

� �

SSRDigital Power Control Series

43

Features

DPC-I adopts zero-cross triggering to control power,which can be used

for temperature control of forming machine, blowing machine or other

resistance loads with SSR-DV

There is no stabilized voltage output

Have good shock-resistant, small overall dimensions, light weight, high

performance-price ratio

Have full power output and you can set the time of full power output

Technical DataTechnical Data

Working Voltage

Adjustment Range

Phase-shifting Angle

Output Mode

150-220VAC 50/60Hz

0-99%

0-160。

Phase Output

Connection ExampleConnection Example

DPC-I-M

Use Environment Less than 45 ,humidity less than 85%RH℃

99%100%

220V

Output Power

Load Voltage

0%

Remark:

1.DPC-I have three states,non power output(OF),full power output(HP) and set percentage power

output . These three work state have auto memory function after electrifying the meter and can be

circularly changed by “P” key.

2.DPC-I voltage regulator and the load must be power synchronism, if not SCR will be damaged

3.You can use an external switch to control voltage regulators which are in the same phase. If they

are not in the same phase, you can not do that.

Overall Dimensions

Opening Size

52x52x35(mm)

46x45(mm)

DPC

P

DIGITAL POWER CONTROLDIGITAL POWER CONTROL

OUT

%

G FP N L

LOADPower AC220VL

N

FUSE

External Switch

218V

OUT F.P. N L

FUSE

LO

AD

OUT F.P. N L

FUSE

LO

AD

OUT F.P. N L

FUSE

LO

AD

OUT F.P. N L

FUSE

LO

AD

L

N

S1

Output Stability Coefficient 1.5%

Page 26: Solid state relay_catalog

SSRDigital Power Control Series

45

Features

Be fit for forming machine, blowing machine and the other resistive load

with our specialized solid state relay SSR-AVA

There is stabilized voltage output

After start-up you can set the time of full power output

Auto memory function, the stored program will never get lost

External full-power manual control, you can warm up quickly

Technical DataTechnical Data

Working Voltage

Adjustment Range

Phase-shifting Angle

Output Mode

150-220VAC 50/60Hz

0-99%

0-160。

Phase Output

Connection ExampleConnection Example

Use Environment Less than 45 ,humidity less than 85%RH℃

Remark:

1.DPC-III-M have three states,non power output(OF),full power output(HP) and set percentage power

output . These three work state have auto memory function after electrifying the meter and you can be

circularly changed by “P” key.

2.“S1” switch is external manual switch of full power output control. When “SI” is closed, DPC-III-M

output full power, except “OF” and “HP” state. This function can be optional according to practical

application.

3.When multi DPC-III-M were used, DPC-III-M in the same phase can share one external control

switch of full power output.

Overall Dimensions

Opening Size

52x52x46(mm)

46x45(mm)

Output Stability Coefficient 1.5%

1 2

34

24~380VAC

Solid State Relay

SSR-25AVA 25A

INPUT

~~

T1G

R

� �

DPC

P

DIGITAL POWER CONTROLDIGITAL POWER CONTROL

OUT

%

G FP N L

LOADPower AC220VL

N

FUSE

S1

1 2

34

24~380VAC

Solid State Relay

SSR-25AVA 25A

INPUT

~~

T1G

R

� �

DPC

P

DIGITAL POWER CONTROLDIGITAL POWER CONTROL

OUT

%

LOADFUSE

ABC

G FP N L

N

1 2

34

24~380VAC

Solid State Relay

SSR-25AVA 25A

INPUT

~~

T1G

R

� �

DPC

P

DIGITAL POWER CONTROLDIGITAL POWER CONTROL

OUT

%

LOADFUSE

G FP N L

1 2

34

24~380VAC

Solid State Relay

SSR-25AVA 25A

INPUT

~~

T1G

R

� �

DPC

P

DIGITAL POWER CONTROLDIGITAL POWER CONTROL

OUT

%

LOADFUSE

G FP N L

A1 B1 C1

A2 B2 C2

SCR3-LA

Control ignalSControl ignalS

N

COM

CON

-

+

AB

C

N

380VACThree Phase

Features

Economy three phase thyristor power regulator,enhance the product value.

The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world

Latest technology:small size, stable output power, good cooling effect.

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Output mode: phase output

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

Dimension(mm)

Installation Dimension(mm)

25A,40A,75A,90A,120A

50Hz/60Hz

Three phase 380VAC FAN220VAC

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

100X110X145(WXLXH)

90X80(WXL)

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SSRThree Phase SCR Power Regulator

46

Type-selection

Mode Load Voltage Maximum UsingCurrent

Maximum UsingPower

ReferenceRadiator

ReferenceFan

SCR3-25LA

SCR3-40LA

SCR3-75LA

SCR3-90LA

SCR3-120LA

380VAC

380VAC

380VAC

380VAC

380VAC

12.5AX3

20AX3

37.5AX3

45AX3

60AX3

2.7KWX3

4.4KWX3

8.2KWX3

9.9KWX3

13.2KWX3

G-80,D-120

C-110

C-110,E-110

L-150,E-110

L-150,L-200

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

80X80(mm)

0%

20%

40%

60%

80%

100%

4mA 20mA

SCR3-LA(Economy Type)

Page 27: Solid state relay_catalog

Control ignalSControl ignalS

-

+

ABCN

380VACThree Phase

Features

With automatic protective function,built-in fast fuse

Input voltage range suitable for around the world

Vacuum welding technique,good quality and long service life

Latest technology:small size, stable output power, good cooling effect.

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Output mode: phase output

Protective cover to prevent electrical shock hazard

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

Dimension(mm)

Installation Dimension(mm)

40A,75A

50Hz/60Hz

Three phase 380VAC FAN220VAC

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

126X130X152(WXLXH)

116X90(WXL)

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SSRThree Phase SCR Power Regulator

48

0%

20%

40%

60%

80%

100%

4mA 20mA

Remark:

1.The main circuit adopts three-phase four-wire input without requirement for phase sequence.

2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be

locked tightly, or SCR will be burned by terminals’ heating.

3.There is a fast fuse built in SCR for over current and short circuit protection.Please replace with

fuse of equivalent specification when the fast fuse is burned out,and don't use the one with higher

fusing ampere.

4.When Y connection is used for three-phase load,the center of Y should be connected with zero

line,if not so,relative equilibrium of the three-phase is required.

5.During the use of module,when the load power is big or the radiating condition is bad,please

consider wind cooling.

U

Control ignalSControl ignalS

N

COM

CON

-

+

AB

C

N

380VACThree Phase

Features

Simple three phase four-wire thyristor power regulator,simple installation

and wirre connection

The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world

Latest technology:small size, stable output power, good cooling effect.

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Output mode: phase output

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

Dimension(mm)

Installation Dimension(mm)

40A,75A

50Hz/60Hz

Three phase 380VAC FAN220VAC

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

100X140X145(WXLXH)

90X80(WXL)

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

Connection ExampleConnection Example

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SSRThree Phase SCR Power Regulator

47

0%

20%

40%

60%

80%

100%

4mA 20mA

V W

LINE AC380V

LOAD

SCR POWER REGULATOR

SCR3-KW-4

Remark:

1.The main circuit adopts three-phase four-wire input without requirement for phase sequence.

2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be

locked tightly, or SCR will be burned by terminals’ heating.

3.Module protection:please use semi-conductive fast fuse for over current protection.

4.When Y connection is used for three-phase load,the center of Y should be connected with zero

line,if not,relative equilibrium of three-phase is required.

5.During use of module, when the load power is more than 15KW, it’s best to be equipped with proper

radiator, and heatconducting silicon grease should be coated between radiator and SCR backboard

,and cool by wind.

SCR3-KW-4(Simple Type)

N

COM

SCR POWER REGULATOR

FU FU FU

MODE:

MAIN SOURCE:

INPUT:

CURRENT:

220VAC 380VAC

PHASE ANGLE ZERO CROSSING

4-20mA 1-5VDC

40A 75A 90A 120A

!N

-

+INPUT

U V W CON

+5V

R S T

PRSCR-LA

Page 28: Solid state relay_catalog

Features

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

Dimension(mm)

Installation Dimension(mm)

75A,90A,120A

50Hz/60Hz

Three phase 380VAC FAN220VAC

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

75A,90A:110X230X165(WXLXH) 120A:110X280X165(WXLXH)

100X160(WXL)

Connection ExampleConnection Example

SSRThree Phase SCR Power Regulator

50

Features

Multipurpose LED indication for working condition

With automatic protective function,built-in fast fuse

Input voltage range suitable for around the world

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Linear phase shift control circuit, with good stability and high precision

Modularized, high voltage resistant, more safe and reliable

Adjustable for maximum and minimum output

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

Dimension(mm)

Installation Dimension(mm)

25A,40A

50Hz/60Hz

Three phase 380VAC FAN220VAC

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

112X135X165(WXLXH)

101X95(WXL)

Connection ExampleConnection Example

SSRThree Phase SCR Power Regulator

49

Remark:

1.The main circuit adopts three-phase three-wire input without requirement for phase sequence.

2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be

locked tightly, or SCR will be burned by terminals’ heating.

3.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was

blown, the yellow LED is showing, right now please check the load circuit short or not or partial

discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of

the same rating. Please never hop up the fuse ampere.

4.For Y connection load, the center can not be to zero line, or SCR will lose control.

5.During use of module, when the load power is big or the radiating condition is bad, please consider

wind cooling

AYSCR-LA J3-SCR-LA

Control ignalSControl ignalS

ABC 380VAC

Three Phase

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SCR POWER REGULATOR

FU FU FU

MODE:

MAIN SOURCE:

INPUT:

CURRENT:

220VAC 380VAC

PHASE ANGLE ZERO CROSSING

4-20mA 1-5VDC

25A 40A 75A 90A

R S T

U V W

UP

PL

IN

OUT

FB

BIAS BIAS

M + -

INPUT

Multipurpose LED indication for working condition

With automatic protective function,built-in fast fuse

Input voltage range suitable for around the world

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Linear phase shift control circuit, with good stability and high precision

Modularized, high voltage resistant, more safe and reliable

Adjustable for maximum and minimum output

Remark:

1.The main circuit adopts three-phase three-wire input without requirement for phase sequence.

2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be

locked tightly, or SCR will be burned by terminals’ heating.

3.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was

blown, the yellow LED is showing, right now please check the load circuit short or not or partial

discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of

the same rating. Please never hop up the fuse ampere.

4.For Y connection load, the center can not be to zero line, or SCR will lose control.If three phase is

unbalanced, you can choose my company’s three-phase four-wire products.

Control ignalSControl ignalS

ABC 380VAC

Three Phase

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SCR POWER REGULATOR

FU FU FU

MODE:

MAIN SOURCE:

INPUT:

CURRENT:

220VAC 380VAC

PHASE ANGLE ZERO CROSSING

4-20mA 1-5VDC

25A 40A 75A 90A

R S T

U V W

UP

PL

IN

OUT

FB

BIAS BIAS

M + -

INPUT

Power supply AC380V state

Control signal input state

Output state

Fast fuse state or phase-missing state

PL

IN

OUT

FB

BIAS BIAS

M + -Controlsignalinput4-20mADC0-5VDC0-10V

Adjustminimumoutput

Adjustmaximumoutput

InternalpowervoltageDC5V

Power supply AC380V state

Control signal input state

Output state

Fast fuse state or phase-missing state

PL

IN

OUT

FB

BIAS BIAS

M + -Controlsignalinput4-20mADC0-5VDC0-10V

Adjustminimumoutput

Adjustmaximumoutput

InternalpowervoltageDC5V

Page 29: Solid state relay_catalog

Features

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

75A 90A 120A 150A 200A 250A

50Hz/60Hz

Three phase 380VAC(three-phase three-wire)

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

Connection ExampleConnection Example

SSRThree Phase SCR Power Regulator

52

Features

Multipurpose LED indication for working condition

With over temperature protective function

Input voltage range suitable for around the world

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Novel structure,high efficiency,high quality

Modularized, high voltage resistant, more safe and reliable

Built-in fast fuse with over current protective function

Technical DataTechnical Data

Rated Current

Operation Frequency

Rated Voltage

Output Mode

Control Signal

Use Environment

Dimension(mm)

Installation Dimension(mm)

40A,75A,90A

50Hz/60Hz

Three phase 380VAC

Phase Output

4-20mA/0-5V/0-10V/Potentiometer

Less than 45 ,humidity less than 90%RH℃

140X200X150(WXLXH)

130X170(WXL)

Connection ExampleConnection Example

SSRThree Phase SCR Power Regulator

51

Remark:

1.The main circuit adopts three-phase four-wire input without requirement for phase sequence.

2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be

locked tightly, or SCR will be burned by terminals’ heating.

3.There is a fast fuse built in SCR for over current and short-circuit protection.Please replace with

fuse of equivalent specification when the fast fuse is burned out,and don't use the one with higher

fusing ampere.

4.When Y connection is used for three-phase load,the center of Y should be connected with zero

line,if not so,relative equilibrium of the three-phase is required.

HNSCR-LA HNSCR-LA-ZQ

Control ignalSControl ignalS

ABC 380VAC

Three Phase

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SCR POWER REGULATOR

FU FU FU

MODE:

MAIN SOURCE:

INPUT:

CURRENT:

220VAC 380VAC

PHASE ANGLE ZERO CROSSING

4-20mA 1-5VDC

25A 40A 75A 90A

R S T

U V W

UP

PL

IN

OUT

FB

Auxiliary Power supply AC220V state

Control signal input state

Output state

Fast fuse state or phase-missing state

PL

IN

OUT

FB

Novel structure,high quality

With over temperature protective function

Multipurpose LED indication for working condition

Adjustable for maximum and minimum output

Applied for high power load

Input voltage range suitable for around the world

Input mode:4-20mA/0-5V/0-10V/Potentiometer

Remark:

The main circuit adopts three-phase four-wire input without requirement for phase sequence.

For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be

locked tightly, or SCR will be burned by terminals’ heating.

When Y connection is used for three-phase load,the center of Y should be connected with zero line,if

not so,relative equilibrium of the three-phase is required.

When the temperature of radiator exceeds 75 °C,the modules will stop working automatically,and

only the power indicating light is bright on the moment.

CONTROL

A 1C AC2 M + - E3 E2 E1

N

Dimension(mm) WXLXH

Installation Dimension(mm)

170X260X250 170X310X250 170X360X250

150X150 WXL)( 150X200(WXL) 150X250(WXL)

Control ignalSControl ignalS

ABC 380VAC

Three Phase

SET

PV

SV

ALM1 ALM2ONAT OFF

RXMTA-2000

4-20mA

0-5VDC

0-10VDC

4-20mA

0-5VDC

0-10VDC

Temperaturesensor

SCR POWER REGULATOR

FU FU FU

MODE:

MAIN SOURCE:

INPUT:

CURRENT:

220VAC 380VAC

PHASE ANGLE ZERO CROSSING

4-20mA 1-5VDC

25A 40A 75A 90A

R S T

U V W

UP

PL

IN

OUT

FB

Auxiliary Power supply AC220V state

Control signal input state

Output state

Phase-missing state

PL

IN

OUT

FB

CONTROL

A 1C AC2 M + - E3 E2 E1

N

A 1CA 1C AC2AC2 M + - E3 E2 E1

AC220VAuxiliary power

TIC Inputsignal

If you do not usepotentiometer,E2and E3 must be shorted

A 1CA 1C AC2AC2 M + - E3 E2 E1

AC220VAuxiliary power

TIC Inputsignal

If you do not usepotentiometer,E2and E3 must be shorted