SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available:...

6
Understanding Interim Tier 4 Emissions Compliance Without Sacrificing Performance Why the change? New federal emissions regulations require a 90% reduction in particulate matter and a 50% drop in nitrogen oxides. How do new engines meet these stringent requirements? Engines 75hp and above use a catalyzed exhaust filter that contains a Diesel Oxidation Catalyst (DOC) and a Diesel Particulate Filter (DPF). Under normal operating conditions, the DOC reacts with exhaust gases to reduce carbon monoxide, hydrocarbons, and some particulate matter. The downstream DPF forces exhaust gases to flow through porous channel walls, trapping and holding the remaining particulate matter (soot). The trapped particles are eventually oxidized through a cleaning process called Regeneration. What is Passive Regeneration? Passive Regeneration is a natural cleaning process that occurs when the temperature, load and speed produce exhaust heat that oxidizes the particulate matter in the DPF under normal operating conditions and turns it to ash. What is Active Regeneration? If Passive Regeneration cannot be achieved due to low temperature, load, or speed, the engine will automatically adjust to increase the exhaust temperature to oxidize the particulate matter. This is done by tuning the amount of air intake, adjusting injection timing, and injecting a small quantity of fuel into the exhaust stream. An Active Regeneration usually takes about a half an hour to complete. What does the inhibit switch do? The inhibit switch prevents the engine from performing an Active Regeneration. The switch should only be used for special locations where high exhaust temperatures would be a danger. For most applications the switch should be left in the auto Position. What is a Forced Regeneration? After operating with the inhibit switch on it may be necessary to manually tell the engine to perform a regeneration. Holding the inhibit switch up for 5 seconds will force an Active Regeneration to occur. How long will a DPF last? John Deere DPF filters are designed to operate for at least 5000 hours before needing removal for cleaning out accumulated ash. Some field units have experienced 7000 hours or more before requiring service. PASSIVE REGENERATION SOLID FLASHING FLASHING DPF 0-60% 60-70% 70-80% 80-100% 100%+ SOOT LOAD LEVEL DPF DPF HEST 0 1 2 3 4 5 ACTIVE REGENERATION FORCED REGENERATION ALLOWED 50% DERATE SERVICE REGENERATION DURING CLEANING Diesel Particulate Filter (DPF) System Catalyzed Exhaust Filter Diesel Particulate Filter (DPF) Remaining particulate matter entrapped in the DPF are oxidized through a continuous cleaning process called passive regeneration Diesel Oxidation Catalyst (DOC) is part of the DPF system where exhaust gases are transformed to reduce carbon monoxide, hydrocarbons, and some particulate matter Cleaner diesel exhaust with lower particulate mat- ter comes out Diesel exhaust with heavy par- ticulate matter goes in EPA Compliance Without Sacrificing Performance Magnum Mobile Generators meet the new federal emissions regulations without sacrificing power and reliable performance. Powered by EPA compliant Interim Tier 4 engines; the mobile generators 75hp and above use a catalyzed exhaust filter containing a Diesel Oxidation Catalyst (DOC) and a Diesel Particulate Filter (DPF) to reduce carbon monoxide, hydrocarbons and particulate matter. Regeneration Operator Interface Built in Wisconsin, USA Customer Support 24/7/365 GENERATORS reliable flexible available durable customer driven • unsurpassed value Magnum Mobile Flip-Hood Generators Model MMG 25 (shown) (Pages 4–7) Advanced Features: • Patent Approved Flip-Hood/Flip-Tongue Design • Aluminum Sound Attenuated Enclosure • Steel Skid Frame and Trailer • Models with Full Load Run Times Up to 40 Hours Magnum Mobile Generators Model MMG 130 (shown) (Pages 4–7) Advanced Features: • Aluminum Sound Attenuated Enclosure • Steel Skid Frame and Trailer • Models with Full Load Run Times in Excess of 24 Hours • Detachable Generator-Set and Trailer Magnum Lite Generators Model MLG 20 (shown) (Pages 2–3) Advanced Features: • Full Tubular Steel Frame • Durable Powder Coat Finish • Up to 48 Hours Full Load Run Time • External Convenience Outlets with MLG 15, MLG 20, MLG 25 rev 6/14 Customer Driven • Unsurpassed Value Since Magnum was formed in 1988, we have supplied reliable, high quality light and heavy-duty mobile generators for a variety of industries and specialties including: road and commercial construction, construction rental, utility and electrical, oil, gas and mining, government and military, tele- communications, and special events. Magnum generators are built and designed for durable performance to meet any conditions and extreme challenges. Whatever your needs are, Magnum offers solutions to fit the requirements for the application and function of your equipment, available to deliver when and where you need it. ™ trademark and ® registered trademark of Magnum Power Products LLC 90071 For more information: Call: 1-800-926-9768 or 920-361-4442 Fax: 920-361-2214 or Visit: MAGNUMPOWER.com Road and Commercial Construction Magnum mobile generators can be found powering road and commercial construction sites with around the clock performance, supporting contractor schedules to meet critical deadlines. Oil, Gas & Mining Operations Magnum products provide prime power and light for remote work sites such as offshore oil and sands drilling sites, and pit-mining locations around the world. Disaster Relief Magnum products are inventoried and readily available to ship on a moment’s notice to assist in relief efforts for natural or unnatural disasters. Security & Military Actions The United States Government relies on Magnum equipment to power and light critical areas like the Pentagon, U.S Borders, and military bases both here and abroad. Magnum provides power and light solutions that continue to serve our troops on every continent in the world. Specialized Applications Magnum offers flexible solutions to unique applications designing customer products such as generators for space shuttle support, fire and security and special mobile needs for auxiliary and prime power for business and industry.

Transcript of SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available:...

Page 1: SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG

Understanding Interim Tier 4 EmissionsCompliance Without Sacrificing Performance

Why the change? New federal emissions regulations require a 90% reduction in particulate matter and a 50% drop in nitrogen oxides.

How do new engines meet these stringent requirements? Engines 75hp and above use a catalyzed exhaust filter that contains a Diesel Oxidation Catalyst (DOC) and a Diesel Particulate Filter (DPF). Under normal operating conditions, the DOC reacts with exhaust gases to reduce carbon monoxide, hydrocarbons, and some particulate matter. The downstream DPF forces exhaust gases to flow through porous channel walls, trapping and holding the remaining particulate matter (soot). The trapped particles are eventually oxidized through a cleaning process called Regeneration.

What is Passive Regeneration? Passive Regeneration is a natural cleaning process that occurs when the temperature, load and speed produce exhaust heat that oxidizes the particulate matter in the DPF under normal operating conditions and turns it to ash.

What is Active Regeneration? If Passive Regeneration cannot be achieved due to low temperature, load, or speed, the engine will automatically adjust to increase the exhaust temperature to oxidize the particulate matter. This is done by tuning the amount of air intake, adjusting injection timing, and injecting a small quantity of fuel into the exhaust stream. An Active Regeneration usually takes about a half an hour to complete.

What does the inhibit switch do? The inhibit switch prevents the engine from performing an Active Regeneration. The switch should only be used for special locations where high exhaust temperatures would be a danger. For most applications the switch should be left in the auto Position.

What is a Forced Regeneration? After operating with the inhibit switch on it may be necessary to manually tell the engine to perform a regeneration. Holding the inhibit switch up for 5 seconds will force an Active Regeneration to occur.

How long will a DPF last? John Deere DPF filters are designed to operate for at least 5000 hours before needing removal for cleaning out accumulated ash. Some field units have experienced 7000 hours or more before requiring service.

PASSIVE REGENERATION

SOLID FLASHING FLASHING

DPF

0-60% 60-70% 70-80% 80-100% 100%+SOOT LOAD LEVEL

DPF DPF

HEST

0 1 2 3 4 5

ACTIVE REGENERATION

FORCED REGENERATIONALLOWED

50% DERATESERVICE

REGENERATION

DURING CLEANING

Diesel Particulate Filter (DPF) System

Catalyzed Exhaust Filter

Diesel Particulate Filter (DPF)Remaining particulate matter entrapped in the DPF are oxidized through a continuous cleaning process called passive regeneration

Diesel Oxidation Catalyst (DOC)is part of the DPF system where exhaust gases are transformed to reduce carbon monoxide, hydrocarbons, and some particulate matter

Cleaner diesel exhaust with lower particulate mat-ter comes out

Diesel exhaust with heavy par-ticulate matter goes in

EPA Compliance Without Sacrificing Performance

Magnum Mobile Generators meet the new federal emissions regulations without sacrificing power and reliable performance. Powered by EPA compliant Interim Tier 4 engines; the mobile generators 75hp and above use a catalyzed exhaust filter containing a Diesel Oxidation Catalyst (DOC) and a Diesel Particulate Filter (DPF) to reduce carbon monoxide, hydrocarbons and particulate matter.

Regeneration Operator Interface

Built in Wisconsin, USACustomer Support 24/7/365

G E N E R AT O R Sreliable • flexible • available • durable

customer driven • unsurpassed value

Magnum Mobile Flip-Hood GeneratorsModel MMG 25 (shown) (Pages 4–7)

Advanced Features:

• Patent Approved Flip-Hood/Flip-Tongue Design

• Aluminum Sound Attenuated Enclosure

• Steel Skid Frame and Trailer

• Models with Full Load Run Times Up to 40 Hours

Magnum Mobile GeneratorsModel MMG 130 (shown) (Pages 4–7)

Advanced Features:

• Aluminum Sound Attenuated Enclosure

• Steel Skid Frame and Trailer

• Models with Full Load Run Times in Excess of 24 Hours

• Detachable Generator-Set and Trailer

Magnum Lite GeneratorsModel MLG 20 (shown) (Pages 2–3)

Advanced Features:

• Full Tubular Steel Frame

• Durable Powder Coat Finish

• Up to 48 Hours Full Load Run Time

• External Convenience Outlets with MLG 15, MLG 20, MLG 25

rev 6/14

Customer Driven • Unsurpassed Value

Since Magnum was formed in 1988, we have supplied reliable, high quality light and heavy-duty mobile generators

for a variety of industries and specialties including: road and commercial construction, construction rental, utility and electrical, oil, gas and mining, government and military, tele-

communications, and special events. Magnum generators are built and designed for durable performance to meet any

conditions and extreme challenges. Whatever your needs are, Magnum offers solutions to fit the requirements for the

application and function of your equipment, available to deliver when and where you need it.

™ trademark and ® registered trademark of Magnum Power Products LLC

90071

For more information:

Call: 1-800-926-9768 or 920-361-4442 Fax: 920-361-2214 or Visit: MAGNUMPOWER.com

Road and Commercial Construction

Magnum mobile generators can be found powering road and commercial construction sites with around the clock performance, supporting contractor schedules to meet critical deadlines.

Oil, Gas & Mining Operations

Magnum products provide prime power and light for remote work sites such as offshore oil and sands drilling sites, and pit-mining locations around the world.

Disaster Relief

Magnum products are inventoried and readily available to ship on a moment’s notice to assist in relief efforts for natural or unnatural disasters.

Security & Military Actions

The United States Government relies on Magnum equipment to power and light critical areas like the Pentagon, U.S Borders, and military bases both here and abroad. Magnum provides power and light solutions that continue to serve our troops on every continent in the world.

Specialized Applications

Magnum offers flexible solutions to unique applications designing customer products such as generators for space shuttle support, fire and security and special mobile needs for auxiliary and prime power for business and industry.

Page 2: SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG

20

Powder-coated Steel Enclosure Easy Access To Service Ports

Lockable Cabinet Door

External Emergency E-stop

External Outlets and Grounding Lug2 - 120V 20 Amp Duplex Outlets2 - 240V 30 Amp Twist Lock2 - 240V 50 Amp Twist Lock

Tubular Steel Frame with Removable Tongue

MLG 8

NANANANA9/937

8.1 / 8.133

120, 240NA60

1.0 (1 Phase)Marathon/Brushless/F

70Yes

NANANA

105 x 68 x 561030 (467)1250 (567)

Tier 4Kubota D1105

Natural13.5 (10.1)

68.53 (1.12)3

18000.70 (2.65)

1-12V/440 CCA

30 (114)48

40N/A

+/-1%21—

1-2200 (998)13

N/A2" Ball

MLG 15

NANANANA

14/1458

13/1354

120, 240NA60

1.0 (1 Phase)Marathon/Brushless/F

68Yes

NANANA

105 x 68 x 561425 (646)1823 (827)

Tier 4Mitsubishi S4L2

Natural22.3 (16.6)107 (1.8)

41800

1.3 (4.92)1-12V/440 CCA

56 (212)43

70N/A

+/-1%222

1-2200 (998)15

N/A2" Ball

MLG 20

NANANANA

20/2083

19/1979

120, 240NA60

1.0 (1 Phase)Marathon/Brushless/F

68Yes

NANANA

105 x 68 x 561455 (660)1853 (841)

Interim Tier 4Isuzu

Natural32.1 (23.9)134 (2.2)

41800

1.8 (6.81)1-12V/720 CCA

56 (212)31

100N/A

+/-1%222

1-2200 (998)15

N/A2" Ball

MLG 25

20/2530/6918/2328/6416/16

6715/15

63120, 139, 208, 220, 240, 277

208, 220, 440, 48060

1.0 (1 Phase) / 0.8 (3 Phase)Marathon/ Brushless/H

68Yes

NANANA

105 x 68 x 561640 (744)2038 (924)

Interim Tier 4Isuzu

Natural32.1 (23.9)134 (2.2)

41800

1.8 (6.81)1-12V/720 CCA

56 (212)31

903 Position Switch (lockable)

+/-1%222

1-2200 (998)15

N/A2" Ball

ModelOutput3 Phase - Standby (kW/kVA)Amps (480/208 V)3 Phase - Prime (kW/kVA)Amps (480/208 V)1 Phase - Standby (kW/kVA)Amps (240V)1 Phase - Prime (kW/kVA)AmpsAC Voltage 1-phaseAC Voltage 3-phaseFrequency HzPower FactorGenerator (Brand/Type/Insulation)Sound (dB(A) 23 Feet @ prime)CSA ListedSize and WeightSkid Mounted ( l x w x h ) inDry Weight lb (kg)Operating Weight lb (kg)Trailer Mounted ( l x w x h ) (in)Dry Weight lb (kg)Operating Weight lb (kg)EngineBrandAspirationHP (prime @ 1800rpm) (kW)Displacement in3 (L)CylindersOperating Speed (rpm)Fuel Consumed prime gph (Lph)Battery (12 volt)CapacitiesFuel Tank gal (L)Approximate Run Time hrsAC DistributionMain BreakerVoltage SelectionVoltage Regulation120V - 20 amp GFCI Duplex240V - 30 amp Twist Lock240V - 50 amp Twist LockTrailerNumber of Axles & Capacity lbs (kg)Tire Size (in)BrakesHitch – Standard

Cost Effective Solution for Mobile Power

Page 3: SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG

www m-p-llc com

CONTROLON

CONTROLOFF

STARTING THE GENERATORDAS STARTEN DES GENERATORSCOMIENZO DEL GENERADORCOMMENCEMENT DU GÉNÉRATEUR

1. TURN CONTROL SWITCH “ON”

2. PUSH “ENGINE START” ENGINESTART

STOPPING THE GENERATORDAS AUFHÖREN DES GENERATORSPARADA DEL GENERADORARRÊT DU GÉNÉRATEUR

1. PUSH “ENGINE STOP”

2. TURN CONTROL SWITCH “OFF”

ENGINESTOP

CONTROLON

CONTROLOFF

CONTROLON

CONTROLOFF

L1 L2 L3

Read and understand the supplied operator’s manual beforeoperating this machine. Failure to do so increases the risk of injury to yourself or others.

Lire et comprendre le manuel de l’utilisateur fourni avec l’appareil avant de l’utiliser. L’omission de le faire augmente le risque de blessure pour vous et pour les autres.

Lea y asegúrese de comprender el manual del operador proporcionado antes de operar esta máquina. De lo contrario, aumenta el riesgo de lesiones a usted y a otras personas.

Vor dem Betrieb dieser Maschine muss das Bedienerhandbuch gelesen und verstanden worden sein. Ein Unterlassen erhöht das eigene Verletzungsrisiko und das anderer.

NEUTRAL BONDED TO FRAMENULLLEITER AM RAHMEN ANGESCHLOSSEN

NEUTRO CONECTADO AL BASTIDOR

POSITION NEUTRE LORSQUE FIXÉ AU CADRE

50A

20A 20A

50A 50A

CONTROL PANELLIGHT

INTERIOR LIGHTS

La génératrice peut démarrer automatiquement, ce qui peut entraîner des blessures graves. Débrancher la batterie avant de faire l’entretien.

Generator can automatically startwhich can cause serious injury. Disconnect battery before servicing.

Der Generator kann automatisch anspringen und schwere Verletzungen verursachen. Vor der Instandsetzung die Batterieverbindungen lösen.

El generador puede arrancar automáticamente, lo que puede causar graves lesiones. Desconecte la batería antes de realizar el servicio técnico.

WARNING

AVERTISSEMENT

ADVERTENCIA

WARNUNG

BATTERYCHARGER

CONTROL ON

CONTROL OFF

I

O

Power Zone™ ControllerSTARTING THE GENERATORDAS STARTEN DES GENERATORSCOMIENZO DEL GENERADORCOMMENCEMENT DU GÉNÉRATEUR

1. PRESS CONTROL POWER SWITCH “ON”

2. PUSH ENGINE START “I”

CONTROLON

CONTROLOFF

I

O

STOPPING THE GENERATORDAS AUFHÖREN DES GENERATORSPARADA DEL GENERADORARRÊT DU GÉNÉRATEUR

1. PUSH ENGINE STOP “O”

2. PRESS CONTROL POWER SWITCH “OFF”

CONTROLON

CONTROLOFF

I

O

New Power Zone ControllerAdvanced User Interface and Diagnostics

State-of-the-art mobile generator control and display.Standard on Interim 4 and Final Tier 4 Models.

Page 4: SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG

Reliable• Advanced microprocessor• Voltage regulation within +/- 1%• Models with full load run times in excess of 24 hours • Air filter condition indicator• Low coolant shutdown• 2 year 2,000 hour warranty

Available Options• Engine Heater *• 60/40 Coolant *• Clutch Fan *• SUPERSTART Generator • Battery Disconnect• Battery Charger• Buck Transformer Kit• 4 Position Phase Switch• Analog Gauges• Cam Locks• Heated Fuel Filter *• Adjustable Air Ducting *• Double Wall Fuel Tank• 36 Hour Full-Load Fuel Tank• Liquid Containment *• Interior Cabinet Light• Control Panel Light• Hitch – 2 5/16" Ball or 3" Ring• Brakes – Electric• Tandem Axle Trailers

MMG 130 (shown)also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG 320, MMG 330, MMG 405, MMG 465, MMG 480

Revolutionary Flip-hood Designavailable models : MMG 25, MMG 35

Delivering Reliable Power & Performance

Tough• Aluminum, lockable enclosure• Steel skid frame and trailer• Durable industrial powder coat finish• Stainless steel exterior hardware

Easy to Use• Voltage selector switch• Multiple convenience outlets• External, lockable fuel cap• Automatic remote start• Detachable generator-set and trailer• Fuel tank integrated into generator-set

Assured Protection• Lockable control box door with diagnostic window• Lockable lug box with safety switch • Trips main breaker when lug door is open • Disables voltage regulator and drops voltage to harmless levels• Guarded cable inlet to prevent access by hand• External emergency stop switch trips main breaker and shuts down engine• Lockable exterior cabinet doors and fuel fill• Individual breakers on convenience outlets• Lockable phase switch• Link Board guard with safety switch (MMG235 & larger) • Trips main breaker when lug door is open • Disables voltage regulator and drops voltage to harmless levels

* COLD WEATHER PACKAGE OPTIONS – Call Factory for Details

Flip-hood/flip-tongue Mobile Generators Standard flip-hood design provides easy open access flip-hoods for routine maintenance and full service, and a large control panel access with centralized location of all electrical connections and wiring. The flip-tongue design permits cross trailer loading for truckload savings as well as added theft prevention on site.

(Four door enclosure is available, call factory for details)

Page 5: SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG

MMG 35

29 / 3643 / 10026 / 3340 / 9226 / 26

10825 / 25

104

601 (1Ø), 0.8 (3Ø)

68Yes

95 x 35 x 522020 (916)

2475 (1123)150 x 57 x 672540 (1152)2990 (1356)Interim Tier 4

John Deere PE4024TF281

Turbo43 (32)

149 (2.4)4

18002.6 (9.8)

1 - 12V/720 CCA

106 (401)36.9

125

+/-1%2

NA2

1 - 3500 (1588)15

Surge2" Ball

MMG 25

20 / 2530 / 6918 / 2328 / 6416 / 16

6715 / 15

63

601 (1Ø), 0.8 (3Ø)

66Yes

95 x 35 x 522048 (929)2517 (1142)

150 x 57 x 672289 (1038) 2758 (1251)Interim Tier 4

Isuzu4LE1NYGV

Natural32 (24)

134 (2.2)4

18001.8 (6.8)

1 - 12V/720 CCA

106 (401)45.4

90

+/- 1%2

NA2

1 - 3500 (1588)15

None2" Ball

MMG 75

69 / 86103 / 239

62 / 7793 / 21460 / 60

25056 / 56

233

601 (1Ø), 0.8 (3Ø)

68Yes

101 x 40 x 683530 (1600)4700 (2131)

166 x 62 x 844240 (1923)5410 (2454) Interim Tier 4

John DeerePE4045HFG92

Turbo97 (72)

274 (4.5) 4

18004.78 (18.1)

1 - 12V/720 CCA

165 (625) 31

300

+/- 1%2

NA3

1 - 6000 (2722)15

Surge3" Ring

MMG 45

40 / 5060 / 13936 / 45

54 / 12537 / 37

15433 / 33

138

601 (1Ø), 0.8 (3Ø)

68Yes

95 x 43.5 x 632418 (1097)3210 (1456)

154 x 59 x 81.52938 (1333)3730 (1692)Final Tier 4

Isuzu 4LE2XAGV01

Turbo57 (42.8)134 (2.2)

41800

3.3 (12.5)1 - 12V/720 CCA

110 (416)30.3

225

+/- 1%2

NA2

1 - 5000 (2268)15

Surge2" Ball

MMG 100 T3

86 / 107129 / 297

78 / 98118 / 272

75 / 75313

71 / 71296

601.0 (1Ø), .8 (3 Ø)

68Yes

96 x 38 x 62 3402 (1543)4361 (1978)

158 x 60 x 844104 (1860)5062 (2296)Tier 3 FlexJohn Deere

PE4045HF285Turbo

122 (91)274 (4.5)

41800

6.2 (23.5)1 - 12V/720 CCA

147 (556)22

400

+/- 1%2

NA3

1 - 6000 (2722)15

Surge3" Ring

Model MMG 75Patented Front Flip-Hood Design

120, 139, 208, 220, 240, 277 208, 220, 440, 480

Marathon / Brushless / H

3 Position Switch (Lockable)

Flip-hood Design StandardModel MMG 25 (shown) also available: MMG 35

Specifications for the four door enclosure design may vary from those listed above. Call factory for details

ModelOutput3 Phase - Standby (kW/kVA)Amps (480/208 V)3 Phase - Prime (kW/kVA)Amps (480/208 V)1 Phase - Standby (kW/kVA)Amps (240V)1 Phase - Prime (kW/kVA)AmpsAC Voltage 1-phaseAC Voltage 3-phaseFrequency HzPower FactorGenerator (Brand/Type/Insulation)Sound (dB(A) 23 Feet @ prime)CSA ListedSize and WeightSkid Mounted ( l x w x h ) inDry Weight lb (kg)Operating Weight lb (kg)Trailer Mounted ( l x w x h ) (in)Dry Weight lb (kg)Operating Weight lb (kg)EngineBrandModel #AspirationHP (prime @ 1800rpm) (kW)

Displacement in3 (L)CylindersOperating Speed (rpm)Fuel Consumed prime gph (Lph)Battery (12 volt)CapacitiesFuel Tank gal (L)Approximate Run Time hrsAC DistributionMain BreakerVoltage SelectionVoltage Regulation120V - 20 amp GFCI Duplex240V - 30 amp Twist Lock240V - 50 amp Twist LockTrailerNumber of Axles & Capacity lbs (kg)Tire Size (in)BrakesHitch – Standard

MMG 100 IT4

86 / 107129 / 297

78 / 98118 / 272

75 / 75313

71 / 71296

601.0 (1Ø), .8 (3Ø)

68Pending

101 x 40 x 683790 (1719)4740 (2150)

166 x 62 x 844480 (2032)5440 (2468)Interim Tier 4

John Deere PE4045HFG92

Turbo121 (90)275 (4.5)

41800

6.2 (23.5)1 - 12V/720 CCA

165 (625)24.4

400

+/- 1%2

NA3

1 - 6000 (2722)15

Surge3" Ring

Marathon / Brushless / H Marathon / Brushless / H

Page 6: SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG

Model MMG 330

MMG 205

174 / 217 261 / 602164 / 205247 / 569155 / 155

646142 / 142

592

601 (1Ø), 0.8 (3Ø)

68Pending

144 x 50 x 776624 (3005)9052 (4106)210 x 86 x 938020 (3638)10448 (4739)Interim Tier 4

John DeerePE6068HFG95

Turbo252 (188) 415 (6.8)

61800

12.8 (48.5)1-12V/1000 CCA

342 (1295)24

800

+/-1%2

NA3

2 - 6000 (2722)16

Surge3” Ring

Model MMG 175

MMG 175

153 / 191230 / 530138 / 172207 / 477125 / 125

521120 / 120

500

601 (1Ø), 0.8 (3Ø)

68Yes

144 x 50 x 776604 (2996)9032 (4097)210 x 86 x 938000 (3629) 10428 (4730)Interim Tier 4

John Deere PE6068HFG94

Turbo217 (162)415 (6.8)

61800

10.9 (41.3)1-12V/1000 CCA

342 (1295)29

700

+/-1%2

NA3

2 - 6000 (2722)16

Surge3” Ring

MMG 320

278 / 348419 / 966256 / 320385 / 888

NANANANANA

208, 48060

0.8 (3Ø)

68Yes

156 x 60 x 908039 (3646)11499 (5215)

230 x 102 x 11010912 (4949)14372 (6519)

Tier 3 FlexJohn Deere

RG6090HF485Turbo

384 (287)548 (9)

61800

17.9 (67.8)2-12V/1000 CCA

459 (1738)24

1200Link/Reconnect Board

+/- 1%2

NA3

2 - 8000 (3629)17.5

Electric3” Ring

MMG 330

290 / 363437 / 1008263 / 329396 / 913

NANANANANA

208, 48060

0.8 (3 Ø)

68Pending

171 x 60 x 909447 (4285)

12907 (5854)230 x 102 x 11012320 (5588)15780 (7158)Interim Tier 4

John Deere PE6090HFG95

Turbo396 (295)549 (9.0)

61800

18.7 (70.8)2-12V/1000 CCA

459 (1738)23

1200Link/Reconnect Board

+/-1%2

NA3

2 - 8000 (3629)17.5

Electric3” Ring

MMG 405

358 / 447 538 / 1241326 / 408

491 / 1132NANANANANA

208, 48060

0.8 (3Ø)

68Yes

175 x 60 x 9612680 (5752)17115 (7763)

250 x 102 x 11615930 (7226)20365 (9237)

Tier 3 FlexJohn Deere

RG6135HF485Turbo

489 (365)824 (13.5)

61800

21.1 (79.9)

616 (2332)29

1600Link/Reconnect Board

+/-1%2

NA3

3 - 8000 (3629)17.5

Electric3” Ring

MMG 235

204 / 255307 / 708186 / 233280 / 647

N/AN/AN/AN/ANA

208, 48060

0.8 (3Ø)

68Yes

132 x 50 x 776510 (2953)9100 (4128)210 x 86 x 938450 (3833)

11040 (5008)Tier 3 FlexJohn Deere

PE6068HF485Turbo

286 (213)415 (6.8)

61800

15.2 (57.5)1-12V/1000 CCA

342 (1295)21

800Link/Reconnect Board

+/-1%2

NA3

2 - 7000 (3175)16

Surge3” Ring

MMG 465

408 / 510613 / 1416373 / 466

561 / 1293N/AN/AN/AN/AN/A

208/48060

0.8 (3Ø)

68Pending

175 x 60 x 9612690 (5756)17125 (7768)

250 x 102 x 11615940 (7230)20375 (9241)

Tier 3 FlexJohn Deere

RG6135HF485Turbo

561 (419)824 (13.5)

61800

26.3 (99.6)

616 (2332)29

1600Link/Reconnect Board

+/-1%2

NA3

3 - 8000 (3629)17.5

Electric3” Ring

MMG 185

177 / 221266 / 613162 / 202243 / 561151 / 151

629137 / 137

571

601 (1Ø), 0.8 (3Ø)

68Pending

132 x 50 x 776510 (2953)9100 (4128)210 x 86 x 938450 (3833)

11040 (5008)Tier 3 FlexJohn Deere

PE6068HF485Turbo

258 (193)415 (6.8)

61800

12.3 (46.6)1-12V/1000 CCA

342 (1295)25

700

+/-1%2

NA3

2 - 7000 (3175)16

Surge3” Ring

MMG 150

127 / 159191 / 441116 / 145174 / 402114 / 114

475106 / 106

442

601 (1Ø), 0.8 (3Ø)

68Yes

132 x 50 x 775944 (2696)8500 (3856)210 x 86 x 937340 (3329)9896 (4489)Tier 3 Flex John Deere

PE4045HF285Turbo

179 (134)275 (4.5)

41800

8.5 (32.3)1-12V/1000 CCA

342 (1295)36

600

+/-1%2

NA3

2 - 6000 (2722)16

Surge3” Ring

MMG 130

107 / 134161 / 37298 / 122

149 / 33996 / 96

40090 / 90

375

601 (1Ø), 0.8 (3Ø)

68Pending

144 x 50 x 775444 (2469)7929 (3596)210 x 86 x 936840 (3102)9325 (4230)Interim Tier 4

John DeerePE4045HFG93

Turbo152 (113)275 (4.5)

41800

7.4 (28.0)1-12V/1000CCA

342 (1295)44

450

+/-1%2

NA3

2 - 6000 (2722)16

Surge 3" Ring

Limited availability of Tier 3 Flex engines – Call for DetailsCall factory for MMG480 specifications

MMG 120

102 / 127153 / 35393 / 116

147 / 33991 / 91

37985 / 85

354

601 (1Ø), 0.8 (3Ø)

68Yes

132 x 50 x 775429 (2463)7914 (3590)210 x 86 x 936825 (3096)9310 (4223)Tier 3 FlexJohn Deere

PE4045HF285Turbo

144 (107)275 (4.5)

41800

7.4 (28)1-12V/1000 CCA

342 (1295)44

450

+/-1%2

NA3

2 - 6000 (2722)16

Surge3” Ring

3 Position Switch (lockable)3 Position Switch (lockable)3 Position Switch (lockable)

120, 139, 208, 220, 240, 277208, 220, 440, 480

120, 139, 208, 220, 240, 277208, 220, 440, 480

120, 139, 208, 220, 240, 277208, 220, 440, 480

Mobile GeneratorSpecifications

MLG 20 (shown)

also available: MLG 8, MLG 15, MLG 25

Specifications are subject to change without notice.

ModelOutput3 Phase - Standby (kW/kVA)Amps (480/208 V)3 Phase - Prime (kW/kVA)Amps (480/208 V)1 Phase - Standby (kW/kVA)Amps (240V)1 Phase - Prime (kW/kVA)AmpsAC Voltage 1-phaseAC Voltage 3-phaseFrequency HzPower FactorGenerator (Brand/Type/Insulation)Sound (dB(A) 23 Feet @ prime)CSA ListedSize and Weight

Skid Mounted ( l x w x h ) inDry Weight lb (kg)Operating Weight lb (kg)Trailer Mounted ( l x w x h ) (in)Dry Weight lb (kg)Operating Weight lb (kg)EngineBrandModel #AspirationHP (prime @ 1800rpm) (kW)Displacement in3 (L)CylindersSpeed (rpm)Fuel Consumed prime gph (Lph)Battery (12 volt)CapacitiesFuel Tank gal (L)Approximate Run Time hrsAC DistributionMain BreakerVoltage SelectionVoltage Regulation120V - 20 amp GFCI Duplex240V - 30 amp Twist Lock240V - 50 amp Twist LockTrailer# of Axles & Capacity lbs (kg)Tire Size (in)BrakesHitch – Standard

Specifications or designs are subject to change without notice.

Marathon/Brushless/HMarathon/Brushless/HMarathon/Brushless/HMarathon/Brushless/HMarathon/Brushless/HTough

• Steel, lockable enclosure• Full tubular steel frame• Durable powder coat finish• Stainless steel exterior hardware

Reliable• Key switch on single phase models• Microprocessor on three phase model• Low oil/high temp shutdowns• Start limit main breaker (single phase only)• Up to 48 hours full load run time• 2 year 2,000 hour warranty• Voltage regulation within +/- 1%

Easy to Use• Self-priming engines• External convenience outlets with MLG 15, MLG 20, MLG 25• Individual breakers• External emergency stop switch• Three phase models also have voltage selector switch, lugs and lug box safety switch, and automatic remote start

24V (2-12V)/1000 CCA

Available Options• Lower Radiator Hose Heater*• 60/40 Coolant *• 720 CCA Gel Cell Battery *• 775 CCA AGM Sealed Battery *• Heated Fuel Filter *• Battery Charger • Battery Disconnect• Liquid Containment – Quiet Pack • 56 Gallon Fuel Tank • Interior Cabinet Light• Central Lift Point Structure • Skid-mounted• Outrigger Package• Spare Tire & Carrier • Combo Hitch – 2/5” Ring/2” Ball• Pintle Ring Hitch – 2.5” or 3" Ring

* COLD WEATHER PACKAGE OPTIONS Call Factory for Details