SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available:...
Transcript of SOLID FLASHING FLASHING customer driven • unsurpassed value · MMG 130 (shown) also available:...
Understanding Interim Tier 4 EmissionsCompliance Without Sacrificing Performance
Why the change? New federal emissions regulations require a 90% reduction in particulate matter and a 50% drop in nitrogen oxides.
How do new engines meet these stringent requirements? Engines 75hp and above use a catalyzed exhaust filter that contains a Diesel Oxidation Catalyst (DOC) and a Diesel Particulate Filter (DPF). Under normal operating conditions, the DOC reacts with exhaust gases to reduce carbon monoxide, hydrocarbons, and some particulate matter. The downstream DPF forces exhaust gases to flow through porous channel walls, trapping and holding the remaining particulate matter (soot). The trapped particles are eventually oxidized through a cleaning process called Regeneration.
What is Passive Regeneration? Passive Regeneration is a natural cleaning process that occurs when the temperature, load and speed produce exhaust heat that oxidizes the particulate matter in the DPF under normal operating conditions and turns it to ash.
What is Active Regeneration? If Passive Regeneration cannot be achieved due to low temperature, load, or speed, the engine will automatically adjust to increase the exhaust temperature to oxidize the particulate matter. This is done by tuning the amount of air intake, adjusting injection timing, and injecting a small quantity of fuel into the exhaust stream. An Active Regeneration usually takes about a half an hour to complete.
What does the inhibit switch do? The inhibit switch prevents the engine from performing an Active Regeneration. The switch should only be used for special locations where high exhaust temperatures would be a danger. For most applications the switch should be left in the auto Position.
What is a Forced Regeneration? After operating with the inhibit switch on it may be necessary to manually tell the engine to perform a regeneration. Holding the inhibit switch up for 5 seconds will force an Active Regeneration to occur.
How long will a DPF last? John Deere DPF filters are designed to operate for at least 5000 hours before needing removal for cleaning out accumulated ash. Some field units have experienced 7000 hours or more before requiring service.
PASSIVE REGENERATION
SOLID FLASHING FLASHING
DPF
0-60% 60-70% 70-80% 80-100% 100%+SOOT LOAD LEVEL
DPF DPF
HEST
0 1 2 3 4 5
ACTIVE REGENERATION
FORCED REGENERATIONALLOWED
50% DERATESERVICE
REGENERATION
DURING CLEANING
Diesel Particulate Filter (DPF) System
Catalyzed Exhaust Filter
Diesel Particulate Filter (DPF)Remaining particulate matter entrapped in the DPF are oxidized through a continuous cleaning process called passive regeneration
Diesel Oxidation Catalyst (DOC)is part of the DPF system where exhaust gases are transformed to reduce carbon monoxide, hydrocarbons, and some particulate matter
Cleaner diesel exhaust with lower particulate mat-ter comes out
Diesel exhaust with heavy par-ticulate matter goes in
EPA Compliance Without Sacrificing Performance
Magnum Mobile Generators meet the new federal emissions regulations without sacrificing power and reliable performance. Powered by EPA compliant Interim Tier 4 engines; the mobile generators 75hp and above use a catalyzed exhaust filter containing a Diesel Oxidation Catalyst (DOC) and a Diesel Particulate Filter (DPF) to reduce carbon monoxide, hydrocarbons and particulate matter.
Regeneration Operator Interface
Built in Wisconsin, USACustomer Support 24/7/365
G E N E R AT O R Sreliable • flexible • available • durable
customer driven • unsurpassed value
Magnum Mobile Flip-Hood GeneratorsModel MMG 25 (shown) (Pages 4–7)
Advanced Features:
• Patent Approved Flip-Hood/Flip-Tongue Design
• Aluminum Sound Attenuated Enclosure
• Steel Skid Frame and Trailer
• Models with Full Load Run Times Up to 40 Hours
Magnum Mobile GeneratorsModel MMG 130 (shown) (Pages 4–7)
Advanced Features:
• Aluminum Sound Attenuated Enclosure
• Steel Skid Frame and Trailer
• Models with Full Load Run Times in Excess of 24 Hours
• Detachable Generator-Set and Trailer
Magnum Lite GeneratorsModel MLG 20 (shown) (Pages 2–3)
Advanced Features:
• Full Tubular Steel Frame
• Durable Powder Coat Finish
• Up to 48 Hours Full Load Run Time
• External Convenience Outlets with MLG 15, MLG 20, MLG 25
rev 6/14
Customer Driven • Unsurpassed Value
Since Magnum was formed in 1988, we have supplied reliable, high quality light and heavy-duty mobile generators
for a variety of industries and specialties including: road and commercial construction, construction rental, utility and electrical, oil, gas and mining, government and military, tele-
communications, and special events. Magnum generators are built and designed for durable performance to meet any
conditions and extreme challenges. Whatever your needs are, Magnum offers solutions to fit the requirements for the
application and function of your equipment, available to deliver when and where you need it.
™ trademark and ® registered trademark of Magnum Power Products LLC
90071
For more information:
Call: 1-800-926-9768 or 920-361-4442 Fax: 920-361-2214 or Visit: MAGNUMPOWER.com
Road and Commercial Construction
Magnum mobile generators can be found powering road and commercial construction sites with around the clock performance, supporting contractor schedules to meet critical deadlines.
Oil, Gas & Mining Operations
Magnum products provide prime power and light for remote work sites such as offshore oil and sands drilling sites, and pit-mining locations around the world.
Disaster Relief
Magnum products are inventoried and readily available to ship on a moment’s notice to assist in relief efforts for natural or unnatural disasters.
Security & Military Actions
The United States Government relies on Magnum equipment to power and light critical areas like the Pentagon, U.S Borders, and military bases both here and abroad. Magnum provides power and light solutions that continue to serve our troops on every continent in the world.
Specialized Applications
Magnum offers flexible solutions to unique applications designing customer products such as generators for space shuttle support, fire and security and special mobile needs for auxiliary and prime power for business and industry.
20
Powder-coated Steel Enclosure Easy Access To Service Ports
Lockable Cabinet Door
External Emergency E-stop
External Outlets and Grounding Lug2 - 120V 20 Amp Duplex Outlets2 - 240V 30 Amp Twist Lock2 - 240V 50 Amp Twist Lock
Tubular Steel Frame with Removable Tongue
MLG 8
NANANANA9/937
8.1 / 8.133
120, 240NA60
1.0 (1 Phase)Marathon/Brushless/F
70Yes
NANANA
105 x 68 x 561030 (467)1250 (567)
Tier 4Kubota D1105
Natural13.5 (10.1)
68.53 (1.12)3
18000.70 (2.65)
1-12V/440 CCA
30 (114)48
40N/A
+/-1%21—
1-2200 (998)13
N/A2" Ball
MLG 15
NANANANA
14/1458
13/1354
120, 240NA60
1.0 (1 Phase)Marathon/Brushless/F
68Yes
NANANA
105 x 68 x 561425 (646)1823 (827)
Tier 4Mitsubishi S4L2
Natural22.3 (16.6)107 (1.8)
41800
1.3 (4.92)1-12V/440 CCA
56 (212)43
70N/A
+/-1%222
1-2200 (998)15
N/A2" Ball
MLG 20
NANANANA
20/2083
19/1979
120, 240NA60
1.0 (1 Phase)Marathon/Brushless/F
68Yes
NANANA
105 x 68 x 561455 (660)1853 (841)
Interim Tier 4Isuzu
Natural32.1 (23.9)134 (2.2)
41800
1.8 (6.81)1-12V/720 CCA
56 (212)31
100N/A
+/-1%222
1-2200 (998)15
N/A2" Ball
MLG 25
20/2530/6918/2328/6416/16
6715/15
63120, 139, 208, 220, 240, 277
208, 220, 440, 48060
1.0 (1 Phase) / 0.8 (3 Phase)Marathon/ Brushless/H
68Yes
NANANA
105 x 68 x 561640 (744)2038 (924)
Interim Tier 4Isuzu
Natural32.1 (23.9)134 (2.2)
41800
1.8 (6.81)1-12V/720 CCA
56 (212)31
903 Position Switch (lockable)
+/-1%222
1-2200 (998)15
N/A2" Ball
ModelOutput3 Phase - Standby (kW/kVA)Amps (480/208 V)3 Phase - Prime (kW/kVA)Amps (480/208 V)1 Phase - Standby (kW/kVA)Amps (240V)1 Phase - Prime (kW/kVA)AmpsAC Voltage 1-phaseAC Voltage 3-phaseFrequency HzPower FactorGenerator (Brand/Type/Insulation)Sound (dB(A) 23 Feet @ prime)CSA ListedSize and WeightSkid Mounted ( l x w x h ) inDry Weight lb (kg)Operating Weight lb (kg)Trailer Mounted ( l x w x h ) (in)Dry Weight lb (kg)Operating Weight lb (kg)EngineBrandAspirationHP (prime @ 1800rpm) (kW)Displacement in3 (L)CylindersOperating Speed (rpm)Fuel Consumed prime gph (Lph)Battery (12 volt)CapacitiesFuel Tank gal (L)Approximate Run Time hrsAC DistributionMain BreakerVoltage SelectionVoltage Regulation120V - 20 amp GFCI Duplex240V - 30 amp Twist Lock240V - 50 amp Twist LockTrailerNumber of Axles & Capacity lbs (kg)Tire Size (in)BrakesHitch – Standard
Cost Effective Solution for Mobile Power
www m-p-llc com
CONTROLON
CONTROLOFF
STARTING THE GENERATORDAS STARTEN DES GENERATORSCOMIENZO DEL GENERADORCOMMENCEMENT DU GÉNÉRATEUR
1. TURN CONTROL SWITCH “ON”
2. PUSH “ENGINE START” ENGINESTART
STOPPING THE GENERATORDAS AUFHÖREN DES GENERATORSPARADA DEL GENERADORARRÊT DU GÉNÉRATEUR
1. PUSH “ENGINE STOP”
2. TURN CONTROL SWITCH “OFF”
ENGINESTOP
CONTROLON
CONTROLOFF
CONTROLON
CONTROLOFF
L1 L2 L3
Read and understand the supplied operator’s manual beforeoperating this machine. Failure to do so increases the risk of injury to yourself or others.
Lire et comprendre le manuel de l’utilisateur fourni avec l’appareil avant de l’utiliser. L’omission de le faire augmente le risque de blessure pour vous et pour les autres.
Lea y asegúrese de comprender el manual del operador proporcionado antes de operar esta máquina. De lo contrario, aumenta el riesgo de lesiones a usted y a otras personas.
Vor dem Betrieb dieser Maschine muss das Bedienerhandbuch gelesen und verstanden worden sein. Ein Unterlassen erhöht das eigene Verletzungsrisiko und das anderer.
NEUTRAL BONDED TO FRAMENULLLEITER AM RAHMEN ANGESCHLOSSEN
NEUTRO CONECTADO AL BASTIDOR
POSITION NEUTRE LORSQUE FIXÉ AU CADRE
50A
20A 20A
50A 50A
CONTROL PANELLIGHT
INTERIOR LIGHTS
La génératrice peut démarrer automatiquement, ce qui peut entraîner des blessures graves. Débrancher la batterie avant de faire l’entretien.
Generator can automatically startwhich can cause serious injury. Disconnect battery before servicing.
Der Generator kann automatisch anspringen und schwere Verletzungen verursachen. Vor der Instandsetzung die Batterieverbindungen lösen.
El generador puede arrancar automáticamente, lo que puede causar graves lesiones. Desconecte la batería antes de realizar el servicio técnico.
WARNING
AVERTISSEMENT
ADVERTENCIA
WARNUNG
BATTERYCHARGER
CONTROL ON
CONTROL OFF
I
O
Power Zone™ ControllerSTARTING THE GENERATORDAS STARTEN DES GENERATORSCOMIENZO DEL GENERADORCOMMENCEMENT DU GÉNÉRATEUR
1. PRESS CONTROL POWER SWITCH “ON”
2. PUSH ENGINE START “I”
CONTROLON
CONTROLOFF
I
O
STOPPING THE GENERATORDAS AUFHÖREN DES GENERATORSPARADA DEL GENERADORARRÊT DU GÉNÉRATEUR
1. PUSH ENGINE STOP “O”
2. PRESS CONTROL POWER SWITCH “OFF”
CONTROLON
CONTROLOFF
I
O
New Power Zone ControllerAdvanced User Interface and Diagnostics
State-of-the-art mobile generator control and display.Standard on Interim 4 and Final Tier 4 Models.
Reliable• Advanced microprocessor• Voltage regulation within +/- 1%• Models with full load run times in excess of 24 hours • Air filter condition indicator• Low coolant shutdown• 2 year 2,000 hour warranty
Available Options• Engine Heater *• 60/40 Coolant *• Clutch Fan *• SUPERSTART Generator • Battery Disconnect• Battery Charger• Buck Transformer Kit• 4 Position Phase Switch• Analog Gauges• Cam Locks• Heated Fuel Filter *• Adjustable Air Ducting *• Double Wall Fuel Tank• 36 Hour Full-Load Fuel Tank• Liquid Containment *• Interior Cabinet Light• Control Panel Light• Hitch – 2 5/16" Ball or 3" Ring• Brakes – Electric• Tandem Axle Trailers
MMG 130 (shown)also available: MMG 45, MMG 75, MMG 100, MMG 120, MMG 150, MMG 175, MMG 185, MMG 205, MMG 235, MMG 320, MMG 330, MMG 405, MMG 465, MMG 480
Revolutionary Flip-hood Designavailable models : MMG 25, MMG 35
Delivering Reliable Power & Performance
Tough• Aluminum, lockable enclosure• Steel skid frame and trailer• Durable industrial powder coat finish• Stainless steel exterior hardware
Easy to Use• Voltage selector switch• Multiple convenience outlets• External, lockable fuel cap• Automatic remote start• Detachable generator-set and trailer• Fuel tank integrated into generator-set
Assured Protection• Lockable control box door with diagnostic window• Lockable lug box with safety switch • Trips main breaker when lug door is open • Disables voltage regulator and drops voltage to harmless levels• Guarded cable inlet to prevent access by hand• External emergency stop switch trips main breaker and shuts down engine• Lockable exterior cabinet doors and fuel fill• Individual breakers on convenience outlets• Lockable phase switch• Link Board guard with safety switch (MMG235 & larger) • Trips main breaker when lug door is open • Disables voltage regulator and drops voltage to harmless levels
* COLD WEATHER PACKAGE OPTIONS – Call Factory for Details
Flip-hood/flip-tongue Mobile Generators Standard flip-hood design provides easy open access flip-hoods for routine maintenance and full service, and a large control panel access with centralized location of all electrical connections and wiring. The flip-tongue design permits cross trailer loading for truckload savings as well as added theft prevention on site.
(Four door enclosure is available, call factory for details)
MMG 35
29 / 3643 / 10026 / 3340 / 9226 / 26
10825 / 25
104
601 (1Ø), 0.8 (3Ø)
68Yes
95 x 35 x 522020 (916)
2475 (1123)150 x 57 x 672540 (1152)2990 (1356)Interim Tier 4
John Deere PE4024TF281
Turbo43 (32)
149 (2.4)4
18002.6 (9.8)
1 - 12V/720 CCA
106 (401)36.9
125
+/-1%2
NA2
1 - 3500 (1588)15
Surge2" Ball
MMG 25
20 / 2530 / 6918 / 2328 / 6416 / 16
6715 / 15
63
601 (1Ø), 0.8 (3Ø)
66Yes
95 x 35 x 522048 (929)2517 (1142)
150 x 57 x 672289 (1038) 2758 (1251)Interim Tier 4
Isuzu4LE1NYGV
Natural32 (24)
134 (2.2)4
18001.8 (6.8)
1 - 12V/720 CCA
106 (401)45.4
90
+/- 1%2
NA2
1 - 3500 (1588)15
None2" Ball
MMG 75
69 / 86103 / 239
62 / 7793 / 21460 / 60
25056 / 56
233
601 (1Ø), 0.8 (3Ø)
68Yes
101 x 40 x 683530 (1600)4700 (2131)
166 x 62 x 844240 (1923)5410 (2454) Interim Tier 4
John DeerePE4045HFG92
Turbo97 (72)
274 (4.5) 4
18004.78 (18.1)
1 - 12V/720 CCA
165 (625) 31
300
+/- 1%2
NA3
1 - 6000 (2722)15
Surge3" Ring
MMG 45
40 / 5060 / 13936 / 45
54 / 12537 / 37
15433 / 33
138
601 (1Ø), 0.8 (3Ø)
68Yes
95 x 43.5 x 632418 (1097)3210 (1456)
154 x 59 x 81.52938 (1333)3730 (1692)Final Tier 4
Isuzu 4LE2XAGV01
Turbo57 (42.8)134 (2.2)
41800
3.3 (12.5)1 - 12V/720 CCA
110 (416)30.3
225
+/- 1%2
NA2
1 - 5000 (2268)15
Surge2" Ball
MMG 100 T3
86 / 107129 / 297
78 / 98118 / 272
75 / 75313
71 / 71296
601.0 (1Ø), .8 (3 Ø)
68Yes
96 x 38 x 62 3402 (1543)4361 (1978)
158 x 60 x 844104 (1860)5062 (2296)Tier 3 FlexJohn Deere
PE4045HF285Turbo
122 (91)274 (4.5)
41800
6.2 (23.5)1 - 12V/720 CCA
147 (556)22
400
+/- 1%2
NA3
1 - 6000 (2722)15
Surge3" Ring
Model MMG 75Patented Front Flip-Hood Design
120, 139, 208, 220, 240, 277 208, 220, 440, 480
Marathon / Brushless / H
3 Position Switch (Lockable)
Flip-hood Design StandardModel MMG 25 (shown) also available: MMG 35
Specifications for the four door enclosure design may vary from those listed above. Call factory for details
ModelOutput3 Phase - Standby (kW/kVA)Amps (480/208 V)3 Phase - Prime (kW/kVA)Amps (480/208 V)1 Phase - Standby (kW/kVA)Amps (240V)1 Phase - Prime (kW/kVA)AmpsAC Voltage 1-phaseAC Voltage 3-phaseFrequency HzPower FactorGenerator (Brand/Type/Insulation)Sound (dB(A) 23 Feet @ prime)CSA ListedSize and WeightSkid Mounted ( l x w x h ) inDry Weight lb (kg)Operating Weight lb (kg)Trailer Mounted ( l x w x h ) (in)Dry Weight lb (kg)Operating Weight lb (kg)EngineBrandModel #AspirationHP (prime @ 1800rpm) (kW)
Displacement in3 (L)CylindersOperating Speed (rpm)Fuel Consumed prime gph (Lph)Battery (12 volt)CapacitiesFuel Tank gal (L)Approximate Run Time hrsAC DistributionMain BreakerVoltage SelectionVoltage Regulation120V - 20 amp GFCI Duplex240V - 30 amp Twist Lock240V - 50 amp Twist LockTrailerNumber of Axles & Capacity lbs (kg)Tire Size (in)BrakesHitch – Standard
MMG 100 IT4
86 / 107129 / 297
78 / 98118 / 272
75 / 75313
71 / 71296
601.0 (1Ø), .8 (3Ø)
68Pending
101 x 40 x 683790 (1719)4740 (2150)
166 x 62 x 844480 (2032)5440 (2468)Interim Tier 4
John Deere PE4045HFG92
Turbo121 (90)275 (4.5)
41800
6.2 (23.5)1 - 12V/720 CCA
165 (625)24.4
400
+/- 1%2
NA3
1 - 6000 (2722)15
Surge3" Ring
Marathon / Brushless / H Marathon / Brushless / H
Model MMG 330
MMG 205
174 / 217 261 / 602164 / 205247 / 569155 / 155
646142 / 142
592
601 (1Ø), 0.8 (3Ø)
68Pending
144 x 50 x 776624 (3005)9052 (4106)210 x 86 x 938020 (3638)10448 (4739)Interim Tier 4
John DeerePE6068HFG95
Turbo252 (188) 415 (6.8)
61800
12.8 (48.5)1-12V/1000 CCA
342 (1295)24
800
+/-1%2
NA3
2 - 6000 (2722)16
Surge3” Ring
Model MMG 175
MMG 175
153 / 191230 / 530138 / 172207 / 477125 / 125
521120 / 120
500
601 (1Ø), 0.8 (3Ø)
68Yes
144 x 50 x 776604 (2996)9032 (4097)210 x 86 x 938000 (3629) 10428 (4730)Interim Tier 4
John Deere PE6068HFG94
Turbo217 (162)415 (6.8)
61800
10.9 (41.3)1-12V/1000 CCA
342 (1295)29
700
+/-1%2
NA3
2 - 6000 (2722)16
Surge3” Ring
MMG 320
278 / 348419 / 966256 / 320385 / 888
NANANANANA
208, 48060
0.8 (3Ø)
68Yes
156 x 60 x 908039 (3646)11499 (5215)
230 x 102 x 11010912 (4949)14372 (6519)
Tier 3 FlexJohn Deere
RG6090HF485Turbo
384 (287)548 (9)
61800
17.9 (67.8)2-12V/1000 CCA
459 (1738)24
1200Link/Reconnect Board
+/- 1%2
NA3
2 - 8000 (3629)17.5
Electric3” Ring
MMG 330
290 / 363437 / 1008263 / 329396 / 913
NANANANANA
208, 48060
0.8 (3 Ø)
68Pending
171 x 60 x 909447 (4285)
12907 (5854)230 x 102 x 11012320 (5588)15780 (7158)Interim Tier 4
John Deere PE6090HFG95
Turbo396 (295)549 (9.0)
61800
18.7 (70.8)2-12V/1000 CCA
459 (1738)23
1200Link/Reconnect Board
+/-1%2
NA3
2 - 8000 (3629)17.5
Electric3” Ring
MMG 405
358 / 447 538 / 1241326 / 408
491 / 1132NANANANANA
208, 48060
0.8 (3Ø)
68Yes
175 x 60 x 9612680 (5752)17115 (7763)
250 x 102 x 11615930 (7226)20365 (9237)
Tier 3 FlexJohn Deere
RG6135HF485Turbo
489 (365)824 (13.5)
61800
21.1 (79.9)
616 (2332)29
1600Link/Reconnect Board
+/-1%2
NA3
3 - 8000 (3629)17.5
Electric3” Ring
MMG 235
204 / 255307 / 708186 / 233280 / 647
N/AN/AN/AN/ANA
208, 48060
0.8 (3Ø)
68Yes
132 x 50 x 776510 (2953)9100 (4128)210 x 86 x 938450 (3833)
11040 (5008)Tier 3 FlexJohn Deere
PE6068HF485Turbo
286 (213)415 (6.8)
61800
15.2 (57.5)1-12V/1000 CCA
342 (1295)21
800Link/Reconnect Board
+/-1%2
NA3
2 - 7000 (3175)16
Surge3” Ring
MMG 465
408 / 510613 / 1416373 / 466
561 / 1293N/AN/AN/AN/AN/A
208/48060
0.8 (3Ø)
68Pending
175 x 60 x 9612690 (5756)17125 (7768)
250 x 102 x 11615940 (7230)20375 (9241)
Tier 3 FlexJohn Deere
RG6135HF485Turbo
561 (419)824 (13.5)
61800
26.3 (99.6)
616 (2332)29
1600Link/Reconnect Board
+/-1%2
NA3
3 - 8000 (3629)17.5
Electric3” Ring
MMG 185
177 / 221266 / 613162 / 202243 / 561151 / 151
629137 / 137
571
601 (1Ø), 0.8 (3Ø)
68Pending
132 x 50 x 776510 (2953)9100 (4128)210 x 86 x 938450 (3833)
11040 (5008)Tier 3 FlexJohn Deere
PE6068HF485Turbo
258 (193)415 (6.8)
61800
12.3 (46.6)1-12V/1000 CCA
342 (1295)25
700
+/-1%2
NA3
2 - 7000 (3175)16
Surge3” Ring
MMG 150
127 / 159191 / 441116 / 145174 / 402114 / 114
475106 / 106
442
601 (1Ø), 0.8 (3Ø)
68Yes
132 x 50 x 775944 (2696)8500 (3856)210 x 86 x 937340 (3329)9896 (4489)Tier 3 Flex John Deere
PE4045HF285Turbo
179 (134)275 (4.5)
41800
8.5 (32.3)1-12V/1000 CCA
342 (1295)36
600
+/-1%2
NA3
2 - 6000 (2722)16
Surge3” Ring
MMG 130
107 / 134161 / 37298 / 122
149 / 33996 / 96
40090 / 90
375
601 (1Ø), 0.8 (3Ø)
68Pending
144 x 50 x 775444 (2469)7929 (3596)210 x 86 x 936840 (3102)9325 (4230)Interim Tier 4
John DeerePE4045HFG93
Turbo152 (113)275 (4.5)
41800
7.4 (28.0)1-12V/1000CCA
342 (1295)44
450
+/-1%2
NA3
2 - 6000 (2722)16
Surge 3" Ring
Limited availability of Tier 3 Flex engines – Call for DetailsCall factory for MMG480 specifications
MMG 120
102 / 127153 / 35393 / 116
147 / 33991 / 91
37985 / 85
354
601 (1Ø), 0.8 (3Ø)
68Yes
132 x 50 x 775429 (2463)7914 (3590)210 x 86 x 936825 (3096)9310 (4223)Tier 3 FlexJohn Deere
PE4045HF285Turbo
144 (107)275 (4.5)
41800
7.4 (28)1-12V/1000 CCA
342 (1295)44
450
+/-1%2
NA3
2 - 6000 (2722)16
Surge3” Ring
3 Position Switch (lockable)3 Position Switch (lockable)3 Position Switch (lockable)
120, 139, 208, 220, 240, 277208, 220, 440, 480
120, 139, 208, 220, 240, 277208, 220, 440, 480
120, 139, 208, 220, 240, 277208, 220, 440, 480
Mobile GeneratorSpecifications
MLG 20 (shown)
also available: MLG 8, MLG 15, MLG 25
Specifications are subject to change without notice.
ModelOutput3 Phase - Standby (kW/kVA)Amps (480/208 V)3 Phase - Prime (kW/kVA)Amps (480/208 V)1 Phase - Standby (kW/kVA)Amps (240V)1 Phase - Prime (kW/kVA)AmpsAC Voltage 1-phaseAC Voltage 3-phaseFrequency HzPower FactorGenerator (Brand/Type/Insulation)Sound (dB(A) 23 Feet @ prime)CSA ListedSize and Weight
Skid Mounted ( l x w x h ) inDry Weight lb (kg)Operating Weight lb (kg)Trailer Mounted ( l x w x h ) (in)Dry Weight lb (kg)Operating Weight lb (kg)EngineBrandModel #AspirationHP (prime @ 1800rpm) (kW)Displacement in3 (L)CylindersSpeed (rpm)Fuel Consumed prime gph (Lph)Battery (12 volt)CapacitiesFuel Tank gal (L)Approximate Run Time hrsAC DistributionMain BreakerVoltage SelectionVoltage Regulation120V - 20 amp GFCI Duplex240V - 30 amp Twist Lock240V - 50 amp Twist LockTrailer# of Axles & Capacity lbs (kg)Tire Size (in)BrakesHitch – Standard
Specifications or designs are subject to change without notice.
Marathon/Brushless/HMarathon/Brushless/HMarathon/Brushless/HMarathon/Brushless/HMarathon/Brushless/HTough
• Steel, lockable enclosure• Full tubular steel frame• Durable powder coat finish• Stainless steel exterior hardware
Reliable• Key switch on single phase models• Microprocessor on three phase model• Low oil/high temp shutdowns• Start limit main breaker (single phase only)• Up to 48 hours full load run time• 2 year 2,000 hour warranty• Voltage regulation within +/- 1%
Easy to Use• Self-priming engines• External convenience outlets with MLG 15, MLG 20, MLG 25• Individual breakers• External emergency stop switch• Three phase models also have voltage selector switch, lugs and lug box safety switch, and automatic remote start
24V (2-12V)/1000 CCA
Available Options• Lower Radiator Hose Heater*• 60/40 Coolant *• 720 CCA Gel Cell Battery *• 775 CCA AGM Sealed Battery *• Heated Fuel Filter *• Battery Charger • Battery Disconnect• Liquid Containment – Quiet Pack • 56 Gallon Fuel Tank • Interior Cabinet Light• Central Lift Point Structure • Skid-mounted• Outrigger Package• Spare Tire & Carrier • Combo Hitch – 2/5” Ring/2” Ball• Pintle Ring Hitch – 2.5” or 3" Ring
* COLD WEATHER PACKAGE OPTIONS Call Factory for Details