SOLiD CWDM Product Spec v1.0 Final · 2020. 11. 6. · CWDM DUAL OADM Single Fiber, Single...

4
Version 1.0 – October 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com SOLiD CWDM CWDM Fiber Optic Multiplexer System Product Specification Easy installation – LGX form factor for rack mounting No provisioning required Plug and play with CWDM SFP/ SFP+/ XFP No performance degradation in handling jumbo packets Multi-protocol support and transparent transport across a single fiber Secure connections without port sharing Zero power consumption SOLiD CWDM Single fiber optical multiplexer system supporting 8 CWDM wavelengths 100% passive optical solution designed to increase capacity of existing fiber deployments Delivers 8 CWDM wavelengths which can also be paired together for bi-directional services Topologies: point-to-point, linear add- drop, and collapsed-ring Applications: fiber reclaim or capacity expansion, cell backhaul, DSLAM Backhaul, Ethernet over wavelength, CPRI networking

Transcript of SOLiD CWDM Product Spec v1.0 Final · 2020. 11. 6. · CWDM DUAL OADM Single Fiber, Single...

  • Version 1.0 – October 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com

    SOLiD CWDM CWDM Fiber Optic Multiplexer System Product Specification

    !

    !

    !

    !

    !

    !

    !

    !

    !

    • Easy installation – LGX form factor for rack mounting

    • No provisioning required

    • Plug and play with CWDM SFP/ SFP+/ XFP

    • No performance degradation in handling jumbo packets

    • Multi-protocol support and transparent transport across a single fiber

    • Secure connections without port sharing

    • Zero power consumption

    SOLiD CWDM Single fiber optical multiplexer system supporting 8 CWDM wavelengths

    100% passive optical solution designed to increase capacity of existing fiber deployments

    Delivers 8 CWDM wavelengths which can also be paired together for bi-directional services

    Topologies: point-to-point, linear add-drop, and collapsed-ring

    Applications: fiber reclaim or capacity expansion, cell backhaul, DSLAM Backhaul, Ethernet over wavelength, CPRI networking

  • SOLiD CWDM – Product Specification

    Version 1.0 – October 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com

    Specifications SOLiD CWDM is a passive system of wave division multiplexing filters used to transport any type of optical

    service over a single fiber including (but not limited to): SONET (OC192, OC48, OC12 and OC3), Carrier

    Ethernet (1GE / 10GE), CPRI / OBSAI (1.228G to 6.144G), Fiber channel (4G/8G), SDF.

    The CWDM units – CMUA and CMUB –are used to match forward with reverse wavelengths.

    CMUA and CMUB Filter Specifications CMUA Max CMUB Max

    Insertion Loss

    Port1: 47 → COM 3.9dB Port1: 55 → COM 1.5dB COM → Port1: 55 3.5dB COM → Port1: 47 1.1dB Port2: 49 → COM 3.1dB Port2: 57 → COM 2.3dB COM → Port2: 57 2.7dB COM → Port2: 49 1.9dB Port3: 51 → COM 2.3dB Port3: 59 → COM 3.1dB COM → Port3: 59 1.9dB COM → Port3: 51 2.7dB Port4: 53 → COM 1.5dB Port4: 61 → COM 3.9dB COM → Port4: 61 1.1dB COM → Port4: 53 3.5dB

    CMUA and CMUB Channel Spacing: 20 nm. Pass band: Channel Wave Length nm Operational Temperature Range: -30°C ~ 70°C. Humidity Range: 0 ~ 90% Hardware Dimension: 29(W) x 129(H) x 145(D)mm. Weight: < 1kg

    The CWDM Add/Drop unit – CAD1 – supports 1 channel. The CAD1 pairs with the CMUA and CMUB units

    and each add/drop unit supports a specific set of wavelengths that include:

    • 1550 west, 1470 east - 1550 east, 1470 west • 1590 west, 1510 east - 1590 east, 1510 west • 1570 west, 1490 east - 1570 east, 1490 west • 1610 west, 1530 east - 1610 east, 1530 west

    OADM CAD1 Filter Specifications OADM CAD1 Max

    Insertion Loss

    COM:East → CH: East 1.1 CH: East → COM: East 1.5 COM:West →CH: West 1.1 CH: West → COM: West 1.5 COM:West COM:East 2.1

    Channel Spacing: 20 nm. Pass band: Channel Wave Length nmnm Operational Temperature Range: -30°C ~ 70°C. Humidity Range: 0 ~ 90% Storage Temperature Range: -40°C ~ 85°C. Humidity Range: 5 ~ 95% Hardware Dimension: 29(W) x 129(H) x 145(D)mm. Weight: < 1kg

  • SOLiD CWDM – Product Specification

    Version 1.0 – October 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com

    Topology Configurations supported by SOLiD CWDM include: point-to- point, linear add-drop, and collapsed-ring.

    Point to Point

    Linear Add-Drop

    Collapsed Ring

  • SOLiD CWDM – Product Specification

    Version 1.0 – October 2014 ©2014 SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com

    Recommended SFPs Wavelength Recommended SFPs CWDM-GBIC-1470 1000BASE-CWDM GBIC 1470 nm CWDM-GBIC-1490 1000BASE-CWDM GBIC 1490 nm CWDM-GBIC-1510 1000BASE-CWDM GBIC 1510 nm CWDM-GBIC-1530 1000BASE-CWDM GBIC 1530 nm CWDM-GBIC-1550 1000BASE-CWDM GBIC 1550 nm CWDM-GBIC-1570 1000BASE-CWDM GBIC 1570 nm CWDM-GBIC-1590 1000BASE-CWDM GBIC 1590 nm CWDM-GBIC-1610 1000BASE-CWDM GBIC 1610 nm *SFPs must be compatible with end device.

    Parts List Product Description Part Number CWDM Mux/Demux Single Fiber A Side CMUA CWDM Mux/Demux Single Fiber B Side CMUB CWDM DUAL OADM Single Fiber, Single Wavelength CAD1-47-55 CWDM DUAL OADM Single Fiber, Single Wavelength CAD1-49-57 CWDM DUAL OADM Single Fiber, Single Wavelength CAD1-51-59 CWDM DUAL OADM Single Fiber, Single Wavelength CAD1-53-61 1310nm/1550nm Bi-directional Coupler - West Facing CPL 55-31 1310nm/1550nm Bi-directional Coupler - East Facing CPL 31-55 19" rack-mount bracket 1U for CAD. R_BRK

    SOLiD 617 North Mary Avenue Sunnyvale, CA 94085 PHONE: 888.409.9997 EMAIL: [email protected] WEB: www.solid.com