Key Features Description Applications Copyright © Peak Scientific Instruments Ltd 2020 — Solaris XE Data sheet Rev 4 RSID 2297 EN —06/02/2020 99-9999 99-9999 Service Kit : Part Number : Your local gas generation partner Peak Scientific’s Solaris XE generator has been engineered using membrane technology to meet the gas delivery requirements for labs using LC-MS, Compact MS or multiple ELSDs. Solaris XE can operate with varying flow rates (up to 35L/min of high purity nitrogen), purity (95-99.5%) and outlet pressure can be adjusted down from 116psi, offering a flexible solution for a variety of applications. The Solaris XE range has been engineered to provide nitrogen to laboratories that utilize an external source of compressed air, which meets a minimum quality grade of ISO 8573-1:2010 Class 1.4.1, and its compact, space-saving chassis allows it to be placed on a benchtop, taking up minimal space in the lab. Nitrogen up to 35L/min, up to 116 psi @ 95-99.5% purity Variable outlet flow, pressure and purity Compact, stackable* system maximising the use of valuable laboratory floor or bench space Colour indicative LED lighting for easy status awareness Manufactured and tested to highest spec in UK, CE/FCC certified Safer and more convenient than pressurized cylinders, dewars or bulk storage 12 month on-site comprehensive warranty Backed by [Peak Protected] global on premise servicing and technical support *units stacked on top of Solaris must not exceed 100kg/220.4lbs LC-MS, Compact MS, Multiple ELSDs, TLD readers Solaris XE Nitrogen generator for LC-MS or multiple ELSDs

Transcript of Solaris XE

Page 1: Solaris XE

Key Features

Description

Applications

Copyright © Peak Scientific Instruments Ltd 2020 — Solaris XE Data sheet Rev 4 RSID 2297 EN —06/02/2020

99-999999-9999 Service Kit :Part Number :

Your local gas generation partner

Peak Scientific’s Solaris XE generator has been engineered using membrane technology to meet the gas delivery requirements for labs using LC-MS, Compact MS or multiple ELSDs. Solaris XE can operate with varying flow rates (up to 35L/min of high purity nitrogen), purity (95-99.5%) and outlet pressure can be adjusted down from 116psi, offering a flexible solution for a variety of applications. The Solaris XE range has been engineered to provide nitrogen to laboratories that utilize an external source of compressed air, which meets a minimum quality grade of ISO 8573-1:2010 Class 1.4.1, and its compact, space-saving chassis allows it to be placed on a benchtop, taking up minimal space in the lab.

Nitrogen up to 35L/min, up to 116 psi @ 95-99.5% purity

Variable outlet flow, pressure and purity Compact, stackable* system maximising the use of valuable laboratory floor or bench space Colour indicative LED lighting for easy status awareness Manufactured and tested to highest spec in UK, CE/FCC certified Safer and more convenient than pressurized cylinders, dewars or bulk storage 12 month on-site comprehensive warranty Backed by [Peak Protected] global on premise servicing and technical support *units stacked on top of Solaris must not exceed 100kg/220.4lbs

LC-MS, Compact MS, Multiple ELSDs, TLD readers

Solaris XENitrogen generator for LC-MS or multiple ELSDs

Page 2: Solaris XE

Peak Scientific UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientific North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Product Certifications

Copyright 2020 Peak Scientific - Rev - Solaris XE Data sheet Rev 4 RSID 2297 EN - 06/02/20

Technical Specifications Solaris XE

Max Flow Rate up to 35 L/min

Max Pressure up to 116 psi / 8 bar (user adjustable)

Purity 95-99.5 %*

Gas Outlets 1 x 1/4 “ BSPP

Min/Max Air Inlet Pressure 80 psi/5.5 bar - 145 psi/10 bar

Min Inlet Air Quality ISO8573 - 1:2010 Class 1.4.1

Contaminants Phthalate & BHT Free

Suspended Liquids None

Operating Temperature 5°C - 30°C / 41°F - °F

Electrical Requirements Universal100 / 230 VAC / 50 / 60 Hz / 0.03 A

Power Consumption 6.9 Watts

Heat Output 25 BTU/Hr

Generator Dimensions (HxWxD) 156 x 343 x 650 mm6.1 x 13.5 x 25.6’’

Generator Weight 15.1 kg / 33.3 lbs

Max Weight Bearing Capability 100 kg / 220.5 lbs

Solaris Compressor compatible NO

*depending on inlet air pressure and outlet flow

Ordering Information

Part Number 3300671

Annual Service www.peakscientific.com/ordering

FPPM Maintenance Plan 3300671-FPPM

Complete Maintenance Plan 3300671-CSP

Supported Maintenance Plan 3300671-SMP

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that your investment continues to be [Protected] by our comprehensive generator care cover. Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 3: Solaris XE

Description

Copyright © Peak Scientific Instruments Ltd 2020 — Solaris XE Waters Data sheet Rev 5 RSID 2950 EN —06/02/2020

99-999999-9999 Service Kit :Part Number :

Your local gas generation partner

Applications

Peak Scientific’s Solaris XE nitrogen generator offers a reliable, compressor-free gas solution that can comfortably meet the demands of most mass spectrometers within Waters’ portfolio of instruments. Using our tried and tested membrane technology, Solaris XE can operate with varying flow rates (up to 35L/min of high purity nitrogen), purity (95-99.5%) and outlet pressure can be adjusted down from 116psi.

Solaris XE for Waters has been designed in collaboration with Waters and is the only compressor-free nitrogen generator available which is tested and approved by Waters for use with the ACQUITY QDa Detector. Solaris XE is fitted with alignment blocks specifically designed to enable the generator to be stacked underneath the ACQUITY QDa in most modular stacking configurations*, providing a compact and discreet space-saving solution within the lab. Alternatively this unit can be wall mounted or free standing on a lab bench.

The Solaris XE has been engineered to provide nitrogen to laboratories that utilize an external source of compressed air, which meets a minimum quality grade of ISO 8573-1:2010 Class 1.4.1.

*Please ask your local sales representative for advice on supported stacking configurations.

) Nitrogen up to 35L/min, up to 116 psi @ 95-99.5% purity

) Tested and approved by Waters

) Compact, wall-mountable and stackable* with Waters ACQUITY QDa, maximizing the use of valuable laboratory floor or bench space

) Variable outlet flow, pressure and purity

) Colour indicative LED lighting for easy system status awareness

) Manufactured and tested to highest spec in UK, CE/FCC/CSA certified

) Safer and more convenient than pressurized cylinders, dewars or bulk storage

) 12 month on-site comprehensive warranty

) Backed by [Peak Protected] global on premise servicing and technical support

) Waters ACQUITY QDa Detector

) A list of instruments that are compatible with Solaris XE can be found on our Waters application list.

Solaris XE for Waters™Dedicated nitrogen solution for ACQUITY™ QDa™

343 mm / 13.5”

650 mm / 25.6”

156 mm

/ 6.2”

Page 4: Solaris XE

Peak Scientific UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientific North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Product Certifications

Copyright 2020 Peak Scientific - Rev - Solaris XE Waters Data sheet Rev 5 RSID 2950 EN - 06/02/20

Technical Specifications Solaris XE for Waters

Max Flow Rate up to 35 L/min

Max Pressure up to 116 psi / 8 bar (user adjustable)

Purity 95% - 99.5%*

Gas Outlets 1 x 1/4 “ BSPP

Min/Max Air Inlet Pressure 80 psi/5.5 bar - 145 psi/10 bar (116 psi/8 bar required for QDa)

Min Inlet Air Quality ISO8573-1:2010 Class 1.4.1**

Contaminants Phthalate & BHT Free

Suspended Liquids None

Operating Temperature 5°C - 30°C / 41°F - °F

Electrical Requirements Universal 100 / 230 VAC / 50 / 60 Hz / 0.03 A

Power Consumption 6.9 Watts

Heat Output 25 BTU/Hr

Generator Dimensions (HxWxD) 156 x 343 x 650 mm6.2 x 13.5 x 25.6’’

Generator Weight 15.1 kg / 33.3 lbs

Max Weight Bearing Capability 100 kg / 220.5 lbs

Solaris Compressor compatible NO

*depending on inlet air pressure and outlet flow

** This unit should be connected to an air supply that, as a minimum, meets ISO8573-1:2010 Class 1.4.1

Ordering Information

Part Number 3300670

Annual Service www.peakscientific.com/ordering

FPPM Maintenance Plan 3300671-FPPM

Complete Maintenance Plan 3300671-CSP

Supported Maintenance Plan 3300671-SMP

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that your investment continues to be [Protected] by our comprehensive generator care cover. Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 5: Solaris XE

Description

Copyright 2018 Peak Scientific - Rev - Solaris Compressor Data sheet Rev 3 RSID 1609 EN - 29/11/18

99-999999-9999 Service Kit :Part Number :

Your local gas generation partner

Key Features

Applications

Solaris Air Compressor Dimensions

Peak Scientific’s Solaris Air Compressor generator has been engineered and designed to support the Solaris 10 Nitrogen generator for labs without an external supply of high quality air. Available in both a 230v and 110v option this unit is suitable for all regions. Solaris can be placed on a benchtop and stacked with the nitrogen generator on top to contain gas supply in a single system whilst saving valuable laboratory workspace.

Solaris has been developed to provide an on-site gas supply of high purity nitrogen for ELSD (Evaporative Light Scattering Detector) for labs using HPLC (High Performance Liquid Chromatography) or alternatively to supply Compact Mass Spectrometer instruments.

) Stackable with Solaris 10 nitrogen generator for ELSD and Compact Mass Specs

) Designed specifically for ELSD and Compact Mass Specs

) Compact, stackable system maximising the use of valuable laboratory floor or bench space

) Manufactured and tested to highest spec in UK, CE/FCC certified

) 12 month on-site comprehensive warranty

) Backed by [Peak Protected] global on premise servicing and technical

) Can supply 1 x Solaris 10 Nitrogen

Solaris Air Compressor Recommended Air Compressor for Solaris 10 Nitrogen generator

406 mm

540 mm 416 mm

Page 6: Solaris XE

Peak Scientific UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientific North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Copyright 2018 Peak Scientific - Rev - Solaris Compressor Data sheet Rev 3 RSID 1609 EN - 29/11/18

Product Certifications

Technical Specifications Air Compressor 110v Air Compressor 230v

Flow Rate Suitable for 1 X Solaris 10 nitrogen combinations

Max Pressure 120 psi (8.27 bar)

Gas Outlets 1 x 1/4" BSPP

Operating Temperature 5°C - 35°C / 41°F - 95°F

Electrical Requirements 100V+/- 10% 50/60Hz 5.4A 115V+/-10% 60Hz 5.3A 230V+/- 10% 50/60Hz 2.8A

Power Consumption 594 Watts 670 Watts 1150 Watts

Heat Output 2420 BTU/hr

Dimensions 416 mm x 540 mm x 406 mm / 16.3” x 21.2” x 15.8”

Weight 41.5 Kg / 91.5 lbs

Ordering Information

Part Number 65-0004 65-0003

Annual Service Kit 08-9454

Complete Maintenance Plan 09-3010

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that you’re investment continues to be [Protected] by our comprehensive generator care cover. Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 7: Solaris XE

Key Features

Solaris 10 Dimensions

Description

Applications

99-999999-9999 Service Kit :Part Number :

Your local gas generation partner

Copyright © Peak Scientific Instruments Ltd 2019 — Solaris 10 Data sheet Rev 7 RSID 1605 EN —30/09/2019

Peak Scientific’s Solaris 10 nitrogen generator has been engineered using membrane technology to meet the gas delivery requirements for labs using ELSD with their High Performance Liquid Chromatography, Compact Mass Spectrometer or for TLD reader instruments. Solaris 10 can operate with varying flow rate (up to 10L/min of high purity nitrogen), purity (up to 99.5%) and outlet pressure is adjustable to 100psi max offering a flexible solution for labs.

With a compact and space-saving chassis, Solaris 10 can be placed on a benchtop and paired with an additional air compressor unit providing air to the system for labs without an in-house air supply or who wish to contain their gas supply in a single system.

) Nitrogen up to 10 L/min, up to 100 psi and up to 99.5% purity

) Variable outlet flow, pressure and purity

) Compact, stackable system maximising the use of valuable laboratory floor or bench space

) Optional Solaris Air Compressor stackable module

) Colour indicative LED lighting for easy status awareness

) Manufactured and tested to highest spec in UK, CE/FCC certified

) Safer and more convenient than pressurized cylinders, dewars or bulk storage

) 12 month on-site comprehensive warranty

) Backed by [Peak Protected] global on premise servicing and technical

) Up to 2 x ELSD instruments

) 1 x Compact Mass Spectrometer

) TLD Readers

Solaris 10Nitrogen generator for ELSD and Compact Mass Spectrometer

156 mm

540 mm416 mm

Page 8: Solaris XE

Peak Scientific UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientific North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Product Certifications

Copyright © Peak Scientific Instruments Ltd 2019 — Solaris 10 Data sheet Rev 7 RSID 1605 EN —30/09/2019

Technical Specifications Solaris 10

Max Flow Rate up to 10 l/min (input dependent)

Max Pressure up to 100 psi / 6.9 bar (user adjustable)

Purity up to 99.5%*

Gas Outlets 1 x 1/4 " BSPP

Min/Max Air Inlet Pressure 80 psi/ 5.5 bar - 130 psi/ 8.9 bar

Min Air Inlet Flow 30 l/min

Min Inlet Air Quality ISO8573 - 1:2010 Class 1.4.1

Contaminants Phthalate & BHT Free

Suspended Liquids None

Operating Temperature 5°C - 35°C / 41°F - 95 °F

Electrical Requirements Universal 100-230 VAC / 50/60 Hz / 0.03A

Power Consumption 6.9 Watts

Heat Output 25 BTU/Hr

Generator Dimensions H x W x D 156 x 416 x 540 mm / 6.1 x 16.4 x 21.3”

Generator Weight 12 kg / 26.4 lbs

*depending on inlet air pressure and outlet flow

Ordering Information

Part Number 65-0001

Annual Service 08-9013

Standard Maintenance Plan 09-3010

Complete Maintenance Plan 09-3010

Solaris Air Compressor 110v 230v Annual Service Kit

Part Number 65-0004 65-0003 08-9454

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that you’re investment continues to be [Protected] by our comprehensive generator care cover. Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 9: Solaris XE

Pressure Swing Adsorption (PSA) has been employed for

decades and is the preferred choice for generating Ultra

High Purity Nitrogen. The technology is self- regenerating,

offering you a reliable and durable source of Ultra High

Purity Nitrogen with little need for attention.

We can make our systems available with or without an

internal air compressor.

PEAK SCIENTIFIC. GO WITH THE FLOW.

Nitrogen Generators NG250(A) - 5000(A)

Copyright 2013 Peak Scientific

Page 10: Solaris XE

Technical Specifications

Ordering Information

Annual Service Kit NG250 - 4000 08-4723

Annual Service Kit NG250A - 4000A 08-4704

Standard Maintenance Plan 09-3110

Complete Maintenance Plan 09-3010

Website: www.peakscientific.com Email: [email protected]

Part Number -excl. air compressor Part Number - incl. air compressor

UK EU US UK EU US

NG250 10-2022 10-2020 10-2010 10-1010 10-1020 10-1030

NG600 10-2070 10-2071 10-2072 10-1060 10-1070 10-1080

NG1000 10-2110 10-2111 10-2130 10-1110 10-1120 10-1130

NG2000 10-2160 10-2170 10-2180 10-1160 10-1170 10-1180

NG3000 10-2210 10-2211 10-2230 10-1210 10-1220 10-1230

NG4000 10-2260 10-2270 10-2280 10-1260 10-1270 10-1280

NG5000 N/A 10-1292 10-1295 10-1291

NG250(A) NG600(A) NG1000(A) NG2000(A) NG3000(A) NG4000(A) NG5000 NG5000A

UHP Nitrogen 250 cc/min 600 cc/min

1000 cc/min

2000 cc/min 3000 cc/min 4000 cc/min 5000 cc/min

Max Outlet Pressure5.5 bar /

80 psi5.5 bar /

80 psi5.5 bar /

80 psi5.5 bar /

80 psi5.5 bar /

80 psi5.5 bar /

80 psi5.5 bar /

80 psi5.5 bar /

80 psi

Purity (N2) 99.9995% 99.9995% 99.9995% 99.9995% 99.9995% 99.9995% 99.9995% 99.998%

Pressure Dewpoint -70ºC / -94ºF

Gas Outlet 1x 1/4” BSP Female

Electrical Requirements

- units without air compressor 230v 50Hz 0.5A / 110v 60Hz 1.2A

- units with air compressor 230v 50Hz 2.2A / 110v 60Hz 5.2A 230v 50Hz 3.6A / 110v 60Hz 8.0A

Power Consumption

- units without air compressor 230v - 115 watts / 110v - 132 watts

- units with air compressor 230v - 506 watts / 110v - 572 watts 230v - 828 watts / 110v - 880 watts

Dimensions (cm/ ins) WxDxH 43 x 41 x 62 / 17 x 16 x 25 43 x 41 x 126 / 17 x 16 x 50

Weight (kg / lbs)

- units without air compressor 33 / 73 47 / 104 57 / 126 77 / 170 80 / 176

- units with air compressor 43.5 / 96 43 / 95 45 / 99 65 / 143 88 / 194 88 / 194

The NG Range of Nitrogen Generator is designed specifically for use as make

up and carrier gas for GC Applications, which require ultra high purity nitrogen

for operation. The NG Range is also suitable for ICP, DSC, TGA, TOD, TMA and

DMA.

Features & Benefits:

Flexible – Available with or without internal air compressor

Purity – Ultra high purity suitable for GC, ICP, DSC, TGA, TOD, TMA and DMA

Single Source Solution – One generator can cater for the requirements of multiple applications

Reliable – Self re- generating CMS column

Simple Installation – Generator designed as plug & play system

Economical – More cost effective than any other gas supply method

Convenient – Gas on demand, no health hazards, no need to worry about running out of gas

Nitrogen Generators NG250(A) - 5000(A)

Peak Scientific’s Quality Management

System conforms to: ISO:9001:2008

Peak Scientific UK

Tel: +44 (0)141 812 8100

Fax: +44 (0)141 812 8200

Peak Scientific North America

Tel: +1 866 647 1649

Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web:

www.peakscientific.com/contact

2007

Product Accreditations:

Page 11: Solaris XE

Infinity XE 50X0 SeriesUser Manual

Copyright © Peak Scientific Instruments Ltd 2019 — Infinity XE 50X0 Series User Manual Rev 1 RSID 2750 EN —27/11/2019

Page 12: Solaris XE

Contents

Change History 3

How to use this Manual 3

Introduction 4

Warranties and Liabilities 5

Warranty & Liability Coverage 5

Safety Notices 7

Symbols 7

Safety Notice to Users 7

Declaration of Conformity 8

Environmental Declaration 9

Technical Specification 10

Unpacking 12

Fittings Kit Contents 13

Installation 14

Generator Environment 14

Generator Overview 15

General Dimensions 15

Rear Connections 16

Inlet Air Quality 16

Electrical Connection 17

Electrical Panel Access 17

Normal Operation 18

On Demand Gas 18

Eco Mode 18

Commissioning 19

Tubing Lengths 19

Service Requirements 20

Service Schedule 20

Peak Protected 21

Cleaning 22

Safely Isolated Condition 22

Safe State After Repair 22

Troubleshooting 23

Page 2

Page 13: Solaris XE

Page 3

Change HistoryRev Comment Name Date

How to use this Manual

This manual is intended for end users and has been written as a reference document where you can skip to the relevant information.

Users can refer to the contents page to find the relevant information.

Please review each of the following sections carefully.

Thank you for selecting Peak Scientific to meet your gas generation needs, and should you require any further assistance or support please do not hesitate to contact Peak Scientific or the Peak Partner from which you purchased your generator.

Page 14: Solaris XE

Page 4

Introduction

The Infinity XE 50 Series delivers performance and value beyond expectations, offering a pure and reliable source of gas. These perpetual flow nitrogen generators are suitable for a variety of applications in your laboratory.

These models provide a source of nitrogen gas with other features including:

• Single Source Solution - One generator can cater for the requirement of multiple applications & multiple laboratories on site

• Durable - Few moving parts with minimum maintenance requirements

• Quiet in operation – Silent whilst operating

• Mobile – Flexibility to position the generator where required

• Simple installation – Generator designed as a plug and play system

• Economical – More cost effective than any other gas supply method

• Convenient – Gas on demand, no hazards, no need to worry about running out of gas

• Eco-mode – Energy efficient eco-mode ensures low running costs

The Infinity XE 50 Series generators are based on proven technology, and selectively remove oxygen, moisture and other gases to leave clean, dry, phthalate free nitrogen.

To ensure these Generator models meet our high expectations with regards to reliability and performance, we have tested them extensively at our manufacturing plant and with end users around the world to ensure reliability and longevity of the system.

Page 15: Solaris XE

Page 5

Warranties and LiabilitiesWarranty & Liability Coverage

1. Peak warrants that, subject to the provisions in this statement, purchased Peak generators, whether purchased directly from Peak or indirectly via an approved, certified and trained distributor or partner (referred to hereafter as a “Peak Partner”) will comply in all material respects with any specifications referred to in your customer order confirmation and, subject to installation and operational guidelines being followed as described in applicable product manuals, shall be free from any defects in quality of materials or workmanship for a period of one year from the date of installation, provided this takes place within 3 months of factory dispatch.

2. Where the purchased generator is from the Precision Hydrogen series, Peak further warrants that, subject to installation and operational guidelines being followed as described in applicable product manuals, the hydrogen cell shall be free from any defects in quality of materials or workmanship for a total period of three years (inclusive of warranty period specified in clause 1) from date of installation, provided this takes place within 3 months of factory dispatch.

3. Where the purchased generator is from the i-Flow 6000 series, Peak further warrants that, subject to installation and operational guidelines being followed as described in applicable product manuals, the generator shall be free from any defects in quality of materials or workmanship for a total period of two years (inclusive of warranty period specified in clause 1) from the date of installation, provided this takes place within 3 months of factory dispatch and the following provisions have also been met: a. you must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on or before the end of the first 12 months of your ownership, and serviced at least once during each subsequent 12 month period thereafter; b. the generator (and any associated equipment) must have been commissioned by Peak or a Peak Partner; c. the feed air or inlet air supply to the generator must comply with ISO 8573-1:2010 Class 1.2.1 at all times; d. your air compressor, dryer, filtration and oil removal systems must be deemed suitable for use by Peak or a Peak Partner, and must be changed and serviced regularly, in line with the equipment manufacturer’s recommended guidelines; and e. any generator failure or fault that is deemed to have been caused by the failure of any upstream equipment, component, part or system (such as air compressor, air treatment or filtration) will be excluded from the warranty described herein.

4. Peak also warrants that any replacement parts whether purchased (directly from Peak, or via a Peak Partner) or supplied as part of any remedial action undertaken in line with the provisions of clauses 12 and 13, shall be free from any defects in quality of materials or workmanship for a period of 180 days from the date of factory dispatch, provided its installation is performed by Peak or a Peak Partner.

5. This warranty does not exclude Peak’s liability in respect of any claim for death or personal injury to any person, in so far as such can be attributed to negligence or breach of duty of care directly resulting from failure of Peak to comply with the provisions in clauses 1, 2, 3 & 4. Exclusions & Limitations

6. This warranty does not cover: a. damage, deterioration or malfunction resulting from an alteration or modification to a generator which has not been carried out by Peak or a Peak Partner; b. damage, deterioration or malfunction resulting from what Peak reasonably believes to be abuse, or misuse of a generator by you or any third party; c. liability for accident or neglect (other than pursuant to clause 5); d. maintenance or repairs which have not been carried out by Peak or a Peak Partner; e. operation of a generator or exposure of a generator to environmental conditions that fall out-with operational guidelines as specified in the applicable product user manual; and f. lightning, power surges or any other acts of God or nature.

7. This warranty is non-transferrable. Only the original owner of the generator may benefit from the terms within this statement.

Page 16: Solaris XE

Page 6

8. Peak shall not be liable in respect of any claim made for costs, damages, losses or expenses (whether consequential, direct, indirect or otherwise) or in any respect howsoever arising including, but not limited to, liability from accident or negligence (other than pursuant to clause 5) that may be suffered by you or any third party.

9. No person or entity is authorised to change the terms and conditions outlined in this warranty statement in any respect, or to create any additional obligations or liabilities for any party involved.

10. This warranty statement supersedes any and all prior warranty agreements between the parties and constitutes the complete, final and exclusive understanding of the parties with respect to the subject matter. All prior negotiations, representations, or promises, whether oral or written, of either party shall be deemed to have been merged herein.

11. If any part of this warranty statement is invalidated, for whatever reason, such part will be deleted and the rest shall remain unaffected, continuing to be in full force and effect. Delivery of Warranty Service

12. Subject to clause 13, and: a. Peak being notified by you, within the duration of the applicable warranty period, of any defect that you think is subject to any warranty valid under clauses 1, 2, 3 or 4; and b. Peak being permitted to inspect the generators, parts and their installation (along with any relevant packaging) Peak shall at its option repair or replace defective generators or parts (including, if necessary, any moving parts and irrespective of runtime). No additional charges will apply, for parts or delivery and, where applicable, labour or travel. Peak will endeavour to deliver this service within 3 working days of your notification.

13. Where, in Peak’s reasonable opinion, a defect is subject to an exclusion described in clause 6, Peak reserves the right to charge for parts or delivery and, where applicable, you may also be charged by Peak for call out, labour or travel in respect of any repair or replacement which you authorize Peak to carry out.

Page 17: Solaris XE

WARNING

WARNING

WARNING

WARNING

CAUTION

Page 7

Safety NoticesPeak Scientific Instruments cannot anticipate every possible circumstance which may represent a potential hazard. The warnings detailed within this manual refer to the most likely potential hazards, but by definition cannot be all inclusive. If the user employs an operating procedure, item of equipment or a method of working which is not specifically recommended by Peak Scientific, the user must ensure that the equipment will not be damaged or become hazardous to persons or property.

Symbols

This manual uses the following symbols to highlight specific areas important to the safe and proper use of the generator.

A WARNING notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause personal injury or in the worst case death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood or met.

A CAUTION notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause damage to the generator or the application. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met.

Caution, risk of electric shock. Ensure power to the generator has been removed before proceeding.

Safety Notice to Users

These instructions must be read thoroughly and understood before installation and operation of your Peak Generator. Use of the generator in a manner not specified by Peak Scientific MAY impair the SAFETY provided by the equipment.

When handling, operating or carrying out any maintenance, personnel must employ safe engineering practices and observe all relevant local health and safety requirements and regulations. The attention of UK users is drawn to the Health and Safety at Work Act 1974, and the Institute of Electrical Engineers regulations.

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment maybe impaired.

Page 18: Solaris XE

Page 8

Declaration of Conformity

We Peak Scientific Instruments Ltd.

Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:

Equipment: Nitrogen Gas Generator

Models: Infinity XE 50 Series

To which this declaration relates, is in conformity with the applicable EC directives, harmonized standards, and other normative requirements.

• Low Voltage Directive 2014/35/EU EN 61010-1: 2010 Electrical Equipment for measurement, control and laboratory use.

• Electromagnetic Compatibility Directive 2014/30/EU EN 61326-1: 2013 Electrical Equipment for measurement, control and laboratory use.

All evaluation, testing and certification issued by:

York EMC Services

Unit 1, Grangemouth Technology Park

Earls Road

Grangemouth

UK

FK3 8UZ

Signed: Name: Chris Pugh

Date: 22/06/2017 Position: Chief Technology Officer

Page 19: Solaris XE

Page 9

Environmental Declaration

We Peak Scientific Instruments Ltd.

Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:

Equipment: Nitrogen Gas Generator

Models: Infinity XE 50 Series

Is fully compliant with the following Directives

• 2012/19/EU WEEE (Waste of Electrical and Electronic Equipment)

• 2011/65/EU RoHS 2 (Restriction of Hazardous Substance)

Peak Scientific Instruments Ltd fully complies with its obligations towards the European WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These obligations are being met within the B2B compliance group.

Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to ensure that our products comply with the principles and requirements of the European recast RoHS (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar directives in the United States and China, for example, have also been captured within this program.

Where a specific certificate of compliance is required, this can be requested, on a product serial number basis, directly from Peak Scientific Instruments Ltd, by contacting us through our website on www.peakscientific.com

Signed: Name: Chris Pugh

Date: 22/06/2017 Position: Chief Technology Officer

Page 20: Solaris XE

Page 10

Technical SpecificationInfinity XE 5010 & 5020Environment

5010 5020

Minimum Operating Ambient Temperature 5°C (41°F)Maximum Operating Ambient Temperature 30°C (86°F)Maximum Relative Humidity 80%

* Maximum safety ambient temperature 30°C** When taken out of storage the generator should be allowed to acclimatize at room temperature for a

minimum of 3 hours before operation.

Inlet Conditions

Minimum Air Inlet Pressure 4.1 bar (60 psi)Maximum Air Inlet Pressure 9.9 bar (145 psi)Minimum Air Inlet Flow Dependant on required flow and purityMinimum Air Quality ISO 8573-1:2010 Class [1.4.1]

Generator Outlets

Maximum Pressure Drop (Inlet-Outlet) 0.7bar (10psi)Maximum Outlet Flow (95% Nitrogen) 130 L/min 260 L/minOutlet Nitrogen Purity 95 - 99.5%Start-Up Time 30 minutesParticles <0.01µmPressure Gauges 2

Electrical Requirements

Voltage 100-230VFrequency 60 Hz / 50 HzCurrent 0.4A at 100V / 0.174A at 230VInput Connection C20 PlugPower Cord (Supplied) C19 socket to local connection (13A min 16A Max)Pollution Degree 2Insulation Category I

General

Dimensions cm (inches) WxDxH 50 x 50 x 99 (19.6 x 19.6 x 39.0)Generator Weight Kg (lbs) 50.4 kg (111 lb) 54.6 kg (120 lb)Shipping Weight Kg (lbs) 67 kg (148 lb) 72 kg (159 lb)

Page 21: Solaris XE

Page 11

Technical SpecificationInfinity XE 5030 & 5040Environment

5030 5040

Minimum Operating Ambient Temperature 5°C (41°F)Maximum Operating Ambient Temperature 30°C (86°F)Maximum Relative Humidity 80%

* Maximum safety ambient temperature 30°C** When taken out of storage the generator should be allowed to acclimatize at room temperature for a

minimum of 3 hours before operation.

Inlet Conditions

Minimum Air Inlet Pressure 4.1 bar (60 psi)Maximum Air Inlet Pressure 9.9 bar (145 psi)Minimum Air Inlet Flow Dependant on required flow and purityMinimum Air Quality ISO 8573-1:2010 Class [1.4.1]

Generator Outlets

Maximum Pressure Drop (Inlet-Outlet) 1.4bar (20psi)Maximum Outlet Flow (95% Nitrogen) 390 L/min 520 L/minOutlet Nitrogen Purity 95 - 99.5%Start-Up Time 30 minutesParticles <0.01µmPressure Gauges 2

Electrical Requirements

Voltage 100-230VFrequency 60 Hz / 50 HzCurrent 0.4A at 100V / 0.174A at 230VInput Connection C20 PlugPower Cord (Supplied) C19 socket to local connection (13A min 16A Max)Pollution Degree 2Insulation Category I

General

Dimensions cm (inches) WxDxH 50 x 50 x 99 (19.6 x 19.6 x 39.0)Generator Weight Kg (lbs) 58.8 kg (130 lb) 63 kg (138 lb)Shipping Weight Kg (lbs) 77 kg (170 lb) 82 kg (180 lb)

Page 22: Solaris XE

Page 12

UnpackingAlthough Peak Scientific takes every precaution with safe transit and packaging, it is advisable to fully inspect the unit for any sign of transit damage.

Check ‘SHOCKWATCH’ and ‘TIP-N-TELL’ labels for signs of rough handling prior to unpacking

Any damage should be reported immediately to the carrier and Peak Scientific or the Peak Partner from where the unit was purchased.

Follow the unpacking instructions posted on the side of the crate. It will require two people to remove the unit from the shipping crate and to manoeuvre the generator to the desired location.

Please save the product packaging for storage or future shipment of the generator.

Note: Included with the generator is a “Fittings Kit” containing mains power leads for UK, EU & US and also all the required fittings and warranty registration card. Be careful not to discard these with the packaging. 

Page 12

Page 23: Solaris XE

Page 13

Fittings Kit ContentsSupplied in the Fittings Kit are all the fittings required to connect the generator to the application. The contents of the Fittings Kit are as follows:

1. 6mm PE Tubing x 3m

2. 12mm PE Tubing x 6m

3. 6mm Push-Fit Fitting x 1

4. 12mm Push-Fit Fitting x 2*

5. 16mm Push-Fit Fitting x 1**

6. Tee fitting x 1

7. Shut-off Valve x 1

8. UK Mains Power Cable x 1

9. EU Mains Power Cable x 1

10. JP Mains Power Cable x 1

11. US Mains Power Cable 230v x 1

12. US Mains Power Cable 110v x 1

13. 4mm Hex Key x 1

14. 5mm Hex Key x 1

15. 8mm Hex Key x 1

All of the generators output ports are located on the output panel at the rear of the unit.

* x1 with 5030 & 5040

** 5030 and 5040 only

Page 24: Solaris XE

Page 14

InstallationGenerator Environment

The generator is designed for indoor use only. It should be installed adjacent to the application(s) it is supplying. If this is not convenient then the unit can be sited elsewhere, however, consideration should be made of the lengths of pipe runs as pressure drops can result from extended runs of pipe.

Performance of the generator is affected by ambient conditions. Note should also be taken to the proximity of Air Conditioning outlets. These can sometimes give rise to “pockets” of air with high relative humidity. Operation of the unit within such a pocket could adversely affect its performance. Consideration should also be given to the air flow around the unit. It is recommended that an air gap of 75mm (3”) should be maintained down both sides and at the rear of the unit. Please refer to the drawing below for the general dimensions of the unit.

Minimum Operating Ambient Temperature: 5 °C (41 °F)

Maximum Operating Ambient Temperature: 30 °C (86 °F)

Page 25: Solaris XE

Page 15

Generator OverviewGeneral Dimensions

The generator must always be placed on a flat, level surface. Failure to do so will affect the performance of the generator.

WARNING

500 mm / 19.6” 500 mm / 19.6”

99

0 m

m / 39

"

Page 26: Solaris XE

Page 16

Rear Connections

Inlet Air QualityThe Nitrogen Generator should be connected to a ISO 8573-1:2010 (1:4:1) source of compressed air. A minimum pressure of 60 psig is required for efficient operation of the Generator. Any doubts as to the suitability of your compressed air supply should be referred to the factory for advice.

A MAXIMUM OIL VAPOUR CONTENT OF 0.01 mg per m^3 is PERMISSIBLE

Air Inlet and Nitrogen Outlet connections are at the rear of the generator in the middle right side of the panel. The Air inlet connection is the right port, 12mm Push-Fit Fitting (5010,5020) 16mm Push-Fit Fitting (5030,5040), Outlet port is 12mm Push-Fit Fitting

12mm Push-Fit Fitting (5010,5020) 16mm Push-Fit Fitting (5030,5040)

Mains Cable

6mm Push-Fit FittingTee Fitting/Shut-Off Valve/12mm Push-Fit Fitting

Page 27: Solaris XE

Page 17

WARNING

Electrical ConnectionConnect the generator to an appropriate 85-264 volt single-phase supply, refer to the generator serial plate for input specification and ensure your supply matches the requirements.

If the appropriate power cord is not supplied; a new plug, rated to at least 12 amps, can be fitted by a qualified electrician.

This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE EARTHED. Before connecting the unit to the mains supply, please check the information on the serial plate. The mains supply must be of the stated AC voltage and frequency.

EARTH/GROUND (E):- Green & Yellow or Green

LIVE (L):- Brown or Black

Neutral (N):- Blue or White

Electrical Panel Access

Changing settings within this enclosure may adversely affect the operation of the generator. This enclosure should not be accessed unless by or under direct instruction from a trained individual.

WARNING

Page 28: Solaris XE

Page 18

Normal OperationThe Infinity XE 50 Series Gas Generators are designed specifically to minimize operator involvement. Given that the systems are installed as described in earlier sections and is serviced in accordance with the specified maintenance recommendations (see Service Requirements), then it should simply be a matter of turning the Generator on when it is required.

The Generator will automatically produce the factory set flow and pressure as detailed in the Technical Specifications.

On Demand GasThe generator will produce nitrogen on demand. If the application is operating and requires a gas flow, the system it is connected to will supply this to suit the requirements of the application. If the application requirement for gas stops, the system will also stop. If the demand from the application starts again, the system will detect the demand for gas and will automatically start again to suit the demand.

Eco ModeWhen demand from the instrument is below 1.2L/min the Infinity XE generator will stop demanding air from the external compressor. If demand from the application starts again, the system will detect the demand for gas and will automatically start up again.

Page 29: Solaris XE

Page 19

CommissioningWith the generator installed as previously described, connect the application to the Nitrogen output port and open the air supply to the unit. On reaching operational pressure the generator will produce Nitrogen at the customer-specified purity. The design of the generator is such that it will deliver up to the rated output flow of Nitrogen, determined by demand of the consuming equipment. Rated flow, purity and pressure are customer-specific and dependent on inlet conditions being met as detailed on the individual generator

The design of the generator is that it will deliver variable purity dependant on the inlet pressure and outlet flow rate. Outlet pressure may be adjusted by the pressure regulator on the rear of the unit, allowing for up to 20 psi pressure drop across the system. Should the demand for the nitrogen stop, the generator will automatically go into "eco-mode" (refer to page 18), shutting off the air inlet. Once the demand restarts the generator automaticcaly resumes producing Nitrogen. The generator is protected from over pressurising.

Tubing LengthsThe diameter of the tubing which will be connected to the gas outlet is important and is determined by the length of tubing required. Failure to follow these recommendations could lead to pressure between generator and application.

> 10 - 40 meters: Use 12/10 (12mm O/D, 10mm I/D) Tubing.

> 40 metres: Please contact Peak Scientific with the relevant distance andwe will calculate the flow resistance and the tubing size required.

The imperial equivalents are: 12/10 = 1/2” O/D, 3/8” I/D.

Air input tubing for 5030 & 5040 is not supplied. 16mm OD, 12mm ID PTFE Tubing is reccomended.

CAUTION

Page 30: Solaris XE

Page 20

Service RequirementsService SchedulePurchase Interval Component Visit

12 Months Infinity XE 50 Series Annual Maintenance Kit www.peakscientific.com/ordering

Page 31: Solaris XE

Page 21

Peak ProtectedWith Peak Scientific you invest in not only a product but peace of mind. With a network of certified Peak engineers stationed throughout the globe, Peak’s rapid response team are never far away and our commitment is to keep your generator running day in, day out, protecting your laboratory workflow.

[Peak Protected] can provide…

Installation A dedicated Peak engineer will visit

your lab to install and setup your generator

IQ/OQCertified assurance for applications requiring documented qualification

Complete planSwift response by a Peak Service

Engineer within 72 hours & planned preventative maintenance

SparesGenuine Peak parts with express

delivery, ensuring optimal performance and lifetime

Premium ProtectedGuaranteed rapid on-site response

within 24 hours & planned preventative maintenance

Technical Support HotlineAround the clock support by phone or online with our global technical

helpdesk

To find out more about protecting your investment visit: www.peakscientific.com/protected

Page 32: Solaris XE

Page 22

CleaningClean the outside of the generator only using warm soapy water and a clean damp cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.

Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator.

Under no circumstances should any solvents or abrasive cleaning solutions be used as these can contain fumes that could be harmful to the generator.

Care should be taken with Leak Detections Liquids.

Safely Isolated ConditionThe unit is in a safely isolated condition when it is disconnected from its application and fully de-pressurised. Directions for isolating the Generator are shown below.

Failure to place the Generator in a safely isolated condition when instructed to do so may lead to personal injury or injury to others and even death.

1. Switch generator off.2. Disconnect from air supply.3. Ensure the output pressure gauge reads zero. (If gauge does not fall to zero, open

the manual ball valve at the outlet port, to allow trapped gas to escape.)4. Disconnect from the application.

Safe State After RepairTo guarantee the generator is in a safe state after a repair, please ensure the following conditions are met;

• All earth leads have been reconnected. Earth leads should be connected to the earth tabs located on the door panels, as shown below.

• The electricity cable has been correctly refitted. The mains cable should be plugged into the IEC power inlet located on the rear panel of the generator. This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE EARTHED.

CAUTION

CAUTION

WARNING

Page 33: Solaris XE

Page 23

TroubleshootingProblem Possible Solution

The Generator will not switch on and the power switch does not illuminate.

• Ensure power cord is plugged into the Generator and that the power socket is turned on.

• Check the fuse in the power cord plug.

• Contact your service provider.

The Generator will not switch on but the power switch is illuminated.

• Disconnect power cord from the rear of the Generator. Open the left hand panel are check that the circuit breaker is turned on (switch in the up position). Reconnect power cord.

• Contact your service provider.

The output pressure has dropped below its original set point.

• Check the pressure regulator at the back of the unit has not been adjusted.

• Check to see if the inlet pressure gauge has dropped below the set air supply pressure.

• If so, check your air supply does not have a pressure drop over the length of tubing and has no leaks.

• Contact your service provider.

Page 34: Solaris XE

Page 24

Go Online or Complete and ReturnYou can register for your FREE 12 month Warranty with ease online at www.peakscientific/protected.

Alternatively, you can send the completed form to Peak Scientific by post or email at [email protected].

Product Warranty RegistrationContact name

Email address

Company

Address

City/town

Postcode

Country

Telephone

Generator serial #

Model type

Installation date

Do you still use an alternative gas solution i.e. cylinders or bulk liquid?

Yes No

What gas requirements do you have in your lab? Hydrogen Nitrogen Zero Air

Extend your cover withPeak Scientific offer comprehensive gas generator after sales support packages. Peak [Protected] aftercare support can guarantee an on-site response within 72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time fix rate. See our enclosed Peak [Protected] leaflet for further information.

Important!You have 1 month to register your Peak Scientific product from the date of installation. Once registered the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your generator, you must notify Peak Scientific immediately by emailing [email protected]. For generators that remain unregistered after 1 month from the shipment date, the warranty will be considered active from the date of factory dispatch.

* Complete Plan only

Go Online or Complete and ReturnWe know that registering any of your recently purchased products is not the first thing on your mind- but it is very important to both of us. Not all warranties are alike and Peak Scientific stand out against other gas suppliers as we offer a comprehensive, quick response, on-site warranty. This means that in the very unlikely case that your gas generator develops a fault we have rapid support teams on-hand around the world who are able to come to your lab and get you back up and running in no time.

Register for your comprehensive 12 month on-site warranty with ease online at www.peakscientific.com/protected.

Alternatively, you can send the completed form to Peak Scientific by post or email at [email protected].

Important!You have 1 month to register your Peak Scientific product from the date of installation. Once registered the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your generator, you must notify Peak Scientific immediately by emailing [email protected]. For generators that remain unregistered after 1 month from the shipment date, the warranty will be considered active from the date of factory dispatch.

Page 35: Solaris XE

Page 25

Page 36: Solaris XE

Page 26

Page 37: Solaris XE

Page 27

Page 38: Solaris XE

Peak ScientificFountain CrescentInchinnan Business ParkInchinnanPA4 9REScotland, UKTel: +44 141 812 8100

For further information on any of our generator products please contact [email protected]

Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries

across every continent around the world. This allows us to provide an industry-leading rapid response

service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top

priority.

To discuss Peak Protected generator cover and payment options speak to your local Peak

Representative or for further information contact: [email protected]

Copyright © Peak Scientific Instruments Ltd 2019 — Infinity XE 50X0 Series User Manual Rev 1 RSID 2750 EN —27/11/2019

Page 39: Solaris XE

Service Kit :

Copyright 2019 Peak Scientifi c - Rev - Infi nity XE 5011-5041 Data sheet � Rev 7� RSID 1974 � EN - 09/01/19

Your local gas generation partner

Part Number :

Description

See Reverse See Reverse

Key Features

Applications

Producing between 10 and 520 L/min of high purity nitrogen gas, Infi nity XE 50 series gas generators can comfortably supply multiple laboratory instruments. O� ering variable N2 purities (95- 99.5%) with a built in purity fail-safe, you can now e� ectively meet the demands of numerous applications such as ELSD, NMR & Glovebox, as well as LC-MS. With no moving parts or mechanical sound, our Infi nity range is easy to service and requires minimal maintenance.

Peak Scientifi c's Infi nity XE series generators have been engineered to provide nitrogen to laboratories that utilize an external source of compressed air, which meets a minimum quality grade of ISO 8573-1:2010 Class 1.4.1. Where required, Peak can provide assistance on external compressors & pre/post fi ltration as part of delivering a complete solution for your needs.

Infi nity XE 5011-5041Single nitrogen source for multiple applications

) Flow rates ranging from 10-520 L/min*

) Variable N2 purities, ranging from 95-99.5%*

) Maximum output pressure of 135 psi

) Built upon tried & tested membrane technology

) Compact, space saving design

) Purity safeguard, warning & auto-shutdown

* Dependent on inlet pressure, inlet/outlet fl ow & inlet air quality

) LC-MS

) ELSD

) Sample Evaporators

) NMR

) FT/MS

) Glovebox

INFINITY XE 5011-5041 Dimensions

500.00mm 500.00mm

995.00mm

Page 40: Solaris XE

Peak Scientifi c UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientifi c North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide o� ce locations, please visit:

Web: www.peakscientifi c.comEmail: marketing@peakscientifi c.com

Product Certifi cationsPeak Scientifi c’s Quality Management System conforms to: ISO:9001:2008

Copyright 2019 Peak Scientifi c - Rev - Infi nity XE 5011-5041 Data sheet � Rev 7� RSID 1974 � EN - 09/01/19

Technical Specifi cations 5011 5021 5031 5041

Flow Rate Min - Max (L/min)* 10-130 20-260 30-390 40-520

Purity N2 Min - Max * 95%-99.5%

Max Outlet Pressure 135 psi

Inlet Air Quality Requirement ISO 8753-1:2010 (1:4:1)

Inlet Air Pressure Requirement 60-145 psi (depending on outlet pressure requirements)

Voltage 100-230 VAC +/- 10%

Frequency 50/60 Hz

Current 0.4A @ 100V / 0.174A @ 230V

Input ConnectionW C20 Plug

Power Cord (Supplied) C19 Socket to local connection

Power Consumption 40 Watts

Operating Temperature 5°C - 30°C / 41°F - 86°F

Pollution Degree 2

Installation Category II

Dimensions mm (inches) W x D x H 500 (19.7) x 500 (19.7) x 995 (39.2)

Weight kg (lbs) 75kg (165lbs) 80kg (176lbs) 85kg (187lbs) 90kg (198lbs)

Shipping weight kg (lbs) 91kg (200lbs) 96kg (211lbs) 101kg (222lbs) 106kg (233lbs)

*Dependant on inlet pressure, inlet/outlet fl ow and Inlet Air Quality

Ordering Information

Part Number 3300189 3300190 3300191 3300192

Annual Service Kit

Visit: www.peakscientifi c.com/orderingFixed Price Preventative Maintenance

Complete/Standard Maintenance Plan

Peak Scientifi c gas generators defi ne the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that you’re investment continues to be [Protected] by our comprehensive generator care cover.

Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 41: Solaris XE

Key Features

i-FlowLab 6XX2 Dimensions

Description

Applications

Copyright 2018 Peak Scientific - Rev - i-FlowLab 6XX2 datasheet Rev 3 RSID 1269 EN - 10/07/18

Service Kit :Part Number :

760 mm (29.92 inch) 160 mm(6.29 inch)

500.00 mm (19.68 inch)1738 m

m (68.42 Inch)

) Real-time monitoring of purity (in ppm) provided by an integrated Oxygen Analyzer

) Modular design allowing for columns to be added as your requirements grow

) Sustainable on-site gas generation, no need for storage of high volumes of bulk gas supply

) Consistent gas purity, so no fluctuations as can be experienced with bulk gas storage

) Minimal maintenance, only scheduled preventative maintenance required to ensure long life and performance of the system

) A safer solution with no storing of highly pressurized gas on-site

) Reduce carbon footprint by removing the requirement for bulk gas supply delivery

) Comprehensive installation including compressed air supply, pipework, pre-filtration system, nitrogen generator and storage

) Multiple LC-MS instruments

) Sample Concentrators

) Whole lab solution

) FT-IR/Glove Boxes/TOC

) Larger scale laboratories

i-FlowLab nitrogen generators have been engineered by Peak Scientific gas generation specialists to meet the supply needs of laboratories which require a large capacity, on-site nitrogen supply. Harnessing the latest gas purification technologies i-FlowLab 6XX2 removes oxygen from air, delivering nitrogen at flow rates from 40 l/min to 989 l/min. Available in over 100 pre-configured flow and purity specifications, i-FlowLab is modular with the option to add columns to increase the flow rate as your nitrogen requirements grow.

The 6XX2 range measures generator purity output as oxygen content in ppm, as opposed to its 6XX1 counterpart which measures oxygen content as a percentage. Integrated with the compressed air pre-filtration system, PureAir, ensures the highest quality nitrogen output by cleaning air before it enters the i-FlowLab generator.

Contact us for detailsSee back page

i-FlowLab 6XX2 Scalable, high-flow, nitrogen generation solution for laboratories

Page 42: Solaris XE

Peak HQTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Copyright 2018 Peak Scientific - Rev - i-FlowLab 6XX2 datasheet Rev 3 RSID 1269 EN - 10/07/18

Product Certifications

Technical Specifications LPM *

Product Name 6012 6022 6032 6042 6052 6062 6072 6082 6092 6102

Oxygen Content 5ppm 30 62 95 113 137 173 199 225 248 278

Oxygen Content 10ppm 40 80 120 150 182 230 265 300 330 370

Oxygen Content 50ppm 58 116 174 230 285 345 400 455 510 565

Oxygen Content 100ppm 65 135 202 270 335 405 462 532 591 644

Oxygen Content 500ppm 89 190 283 362 452 545 634 724 812 900

Oxygen Content 1000ppm 105 205 305 406 508 600 700 795 890 989

Voltage 100-240 VAC +/- 10%

Frequency 50/60 Hz

Current 2.0 - 1.0 Amp

Input Connection C20 Plug

Power Cord (Supplied) C19 Socket to local connection

Power Consumption 250 Watts

Operating Temperature 5°C - 50°C / 41°F - 122°F

Pollution Degree 2

Installation Category II

Width mm (inch) 500 (19.68)

Height mm (inch) 1738 (68.42)

Depth mm (inch)760

(29.92)

920

(36.22)

1080

(42.52)

1240

(42.52)

1400

(55.12)

1560

(61.42)

1720

(67.72)

1880

(74.02)

2040

(80.31)

2200

(86.61)

Weight kg (lbs)197

(433)

282

(620)

367

(807)

452

(994)

537

(1181)

622

(1368)

707

(1555)

792

(1742)

877

(1929)

962

(2116)

Shipping weight kg (lbs)277

(609)

364

(801)

452

(992)

538

(1184)

625

(1375)

712

(1566)

799

(1758)

886

(1949)

973

(2141)

1060

(2333)

Noise Level 59dBa @ 1m

*Performance data is based on 7 bar (G) inlet air pressure and 20 - 25 deg C ambient temperature.

(Flow reference conditions, 20 deg C, 1013 millibar (a), 0% Relative Humidity)

Ordering Information

Part Number 20-6012 20-6022 20-6032 20-6042 20-6052 20-6062 20-6072 20-6082 20-6092 20-6102

Service Kit 08-0318 08-0319

Complete Plan 09-3707 09-3708

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that you’re investment continues to be [Protected] by our comprehensive generator care cover. Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 43: Solaris XE

Key Features

i-FlowLab 6XX1 Dimensions

Description

Applications

Copyright 2020 Peak Scientific - Rev - i-FlowLab 6XX1 datasheet Rev 4 RSID 1268 EN - 07/10/20

Service Kit :Part Number :

760 mm (29.92 inch) 160 mm(6.29 inch)

500.00 mm (19.68 inch)1738 m

m (68.42 Inch)

) Oxygen Anaylzer provides continuous real-time monitoring of purity produced in %

) Modular design allowing for columns to be added as your requirements grow

) Sustainable on-site gas generation, no need for storage of high volumes of bulk gas supply

) Consistent gas purity, so no fluctuations as can be experienced with bulk gas storage

) Minimal maintenance, only scheduled preventative maintenance required to ensure long life and performance of the system

) A safer solution with no storing of highly pressurized gas on-site

) Remote monitoring, Live product status information at your fingertips, wherever you are

) Reduce carbon footprint by removing the requirement for bulk gas supply delivery

) Comprehensive installation including compressed air supply, pipework, pre-filtration system, nitrogen generator and storage

) Multiple LC-MS instruments

) Sample Concentrators

) Whole lab solution

) FT-IR/Glove Boxes/TOC

) Larger scale laboratories

i-FlowLab nitrogen generators have been engineered by Peak

Scientific gas generation specialists to meet the supply needs of

laboratories which require a large capacity, on-site nitrogen supply.

Harnessing the latest gas purification technologies i-FlowLab 6XX1

removes oxygen from air, delivering nitrogen at flow rates from 155 l/min

to 3402 l/min. Available in over 100 pre-configured flow and purity

specifications, i-FlowLab is modular with the option to add columns

to increase the flow rate as your nitrogen requirements grow.

The 6XX1 range measures generator purity output as oxygen

content in percentage, as opposed to its 6XX2 counterpart which

measures oxygen content in ppm. Integrated with the compressed

air pre-filtration system, PureAir, ensures the highest quality nitrogen

output by cleaning air before it enters the i-FlowLab generator.

Contact us for detailsSee back page

i-FlowLab 6XX1 Scalable, high-flow, nitrogen generation solution for laboratories

Page 44: Solaris XE

Peak HQTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Copyright 2020 Peak Scientific - Rev - i-FlowLab 6XX1 datasheet Rev 4 RSID 1268 EN - 07/10/20

Product Certifications

Technical Specifications LPM *

Product Name 6011 6021 6031 6041 6051 6061 6071 6081 6091 6101

Oxygen Content - 0.50% 155 305 450 585 730 874 1015 1160 1300 1450

Oxygen Content - 1% 190 380 530 725 885 1062 1238 1415 1574 1748

Oxygen Content - 2% 245 490 665 845 1065 1280 1480 1685 1885 2090

Oxygen Content - 3% 305 578 810 1025 1278 1574 1815 2065 2330 2580

Oxygen Content - 4% 362 651 915 1115 1420 1704 1988 2272 2556 2840

Oxygen Content - 5% 402 750 1100 1385 1649 2045 2478 2778 3045 3402

Voltage 100-240 VAC +/- 10%

Frequency 50/60 Hz

Current 2.0 - 1.0 Amp

Input Connection C20 Plug

Power Cord (Supplied) C19 Socket to local connection

Power Consumption 250 Watts

Operating Temperature 5°C - 50°C / 41°F - 122°F

Pollution Degree 2

Installation Category II

Width mm (inch) 500 (19.68)

Height mm (inch) 1738 (68.42)

Depth mm (inch)760

(29.92)

920

(36.22)

1080

(42.52)

1240

(42.52)

1400

(55.12)

1560

(61.42)

1720

(67.72)

1880

(74.02)

2040

(80.31)

2200

(86.61)

Weight kg (lbs)197

(433)

282

(620)

367

(807)

452

(994)

537

(1181)

622

(1368)

707

(1555)

792

(1742)

877

(1929)

962

(2116)

Shipping weight kg (lbs)277

(609)

364

(801)

452

(992)

538

(1184)

625

(1375)

712

(1566)

799

(1758)

886

(1949)

973

(2141)

1060

(2333)

Noise Level 59dBa @ 1m

*Performance data is based on 7 bar (G) inlet air pressure and 20 - 25 deg C ambient temperature.

(Flow reference conditions, 20 deg C, 1013 millibar (a), 0% Relative Humidity)

Ordering Information

Part Number 20-6011 20-6021 20-6031 20-6041 20-6051 20-6061 20-6071 20-6081 20-6091 20-6101

Service Kit 08-0318 08-0319

Complete Plan 09-3705 09-3706

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the

world, and come backed by a 12 month warranty. Beyond this period however you can ensure that you’re investment continues

to be [Protected] by our comprehensive generator care cover.

Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the

reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Page 45: Solaris XE

Key Features

Applications

Copyright © Peak Scientifi c Instruments Ltd 2020 — Genius XE Data sheet Rev 7 RSID 2463 EN —10/03/2020

99-999999-9999 Service Kit :Part Number :Your local gas generation partner

Description

Inspired by the success of our best-selling Genius line of nitrogen

gas generators for LC-MS, Genius XE Nitrogen is a cutting-edge

evolution combining advanced technology with refined and robust

engineering. With two models - XE 35 (up to 35 L/min) and XE

70 (up to 70 L/min) - Genius XE Nitrogen provides a premium

standalone nitrogen solution for high performance LC-MS and

other mission-critical laboratory applications where performance

and reliability are paramount.

Featuring Multi-Stage Purification™ and next-generation

integrated compressors with Electronic Compressor Optimization™ (ECO) technology, Genius XE delivers factory

certifiable purity up to 99.5% on-demand, 24/7 with a convenient

fixed annual service interval.

) Variable fl ow up to 70 LPM

) Variable pressure up to 116 psi

) Multi-Stage Purifi cation™ producing analytical grade nitrogen gas up to 99.5% purity

) 2 year comprehensive manufacturer’s warranty*

) Touch-screen full colour user interface for ease of operation

) ECO (Electronic Compressor Optimisation™) technology for low energy consumption and compressor durability

) Next-generation high performance premium compressors, engineered exclusively for Genius XE

) Smaller & quieter than previous generation of Genius

) On-board service scheduling and system diagnostics

) Additional compressor capacity for lower fl ow applications (XE 70 only)

On-demand nitrogen source for:

) LC-MS including new high-sensitivity instruments

) ELSD

) Small sample evaporators

) Other laboratory applications requiring nitrogen

Genius XE Nitrogen High performance nitrogen generator for LC-MS

710 mm / 28”570 mm / 22.5”

650

mm

/ 2

5.6

”10

00

mm

/ 3

9.4

Page 46: Solaris XE

Peak Scientifi c’s Quality Management System conforms to: ISO 9001:2015

Product CertificationsPeak Scientifi c UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientifi c North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide o� ce locations, please visit:www.peakscientifi c.com/o� ces

Web: www.peakscientifi c.comEmail: discover@peakscientifi c.com

Copyright 2020 Peak Scientifi c - Rev - Genius XE Data sheet Rev 7 RSID 2463 EN - 10/03/20

Technical Specifi cations Genius XE 35 Genius XE 70

Max Flow Rate up to 35 L/min up to 70 L/min

Max Pressure 116 psi (8 bar) 116 psi (8 bar)

Gas Outlets 1 x ¼” BSPP 1 x ¼” BSPP

Purity** 95-99.5% 95-99.5%

Max Relative Humidity 80% RH @ 31°C 80% RH @ 31°C

Max Altitude 3000m 3000m

Particles < 0.01 µm < 0.01 µm

Phthalates Phthalate & BHT Free Phthalate & BHT Free

Suspended Liquids None None

Non-Methane Hydrocarbon Content < 1 ppm NMHC < 1 ppm NMHC

Operating Temperature 5°C (41°F) to 35°C (95°F) 5°C (41°F) to 35°C (95°F)

Electrical Requirements 120VAC, 60Hz, 12A or 230VAC, 50/60Hz, 8A 230VAC, 50/60Hz, 11.3A

Power Consumption 960 VA (120V)/1265 VA (230V) 2530 VA

Heat Output 4118 BTU 8785 BTU

Noise Level† 56 dB 59 dB

Generator Dimensions (H x W x D) 650 x 570 x 710 mm25.6 x 22.5 x 28 ”

1000 x 570 x 710 mm39.4 x 22.5 x 28 ”

Generator Weight 92 kg / 202 lbs 147 kg / 325 lbs

Ordering Information

Part Number 3300252 (230VAC) /3300807 (120VAC) 3300253

Annual Servicevisit: www.peakscientifi c.com/ordering

Complete Maintenance Plan

** Factory certifi ed purity with respect to O2 content. Actual purity varies in relation to fl ow (min. 95% at maximum fl ow output)† Noise level expressed as SPL (Sound Pressure Level) measured at 1m from source in a reverberant chamber

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the

world, and come backed by a 2 year warranty*. Beyond this period however you can ensure that your investment continues to

be [Protected] by our comprehensive generator care cover.

Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you

the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a

breakdown.

*Year 2 of warranty subject to generator being serviced at end of year 1 by a Peak-approved agent in accordance with fi xed annual maintenance schedule.

For full terms and conditions visit www.peakscientifi c.com/warranty-statement

Page 47: Solaris XE

Key Features

Applications

Copyright © Peak Scientifi c Instruments Ltd 2020 — Genius XE Data sheet Rev 7 RSID 2463 EN —10/03/2020

99-999999-9999 Service Kit :Part Number :Your local gas generation partner

Description

Inspired by the success of our best-selling Genius line of nitrogen

gas generators for LC-MS, Genius XE Nitrogen is a cutting-edge

evolution combining advanced technology with refined and robust

engineering. With two models - XE 35 (up to 35 L/min) and XE

70 (up to 70 L/min) - Genius XE Nitrogen provides a premium

standalone nitrogen solution for high performance LC-MS and

other mission-critical laboratory applications where performance

and reliability are paramount.

Featuring Multi-Stage Purification™ and next-generation

integrated compressors with Electronic Compressor Optimization™ (ECO) technology, Genius XE delivers factory

certifiable purity up to 99.5% on-demand, 24/7 with a convenient

fixed annual service interval.

) Variable fl ow up to 70 LPM

) Variable pressure up to 116 psi

) Multi-Stage Purifi cation™ producing analytical grade nitrogen gas up to 99.5% purity

) 2 year comprehensive manufacturer’s warranty*

) Touch-screen full colour user interface for ease of operation

) ECO (Electronic Compressor Optimisation™) technology for low energy consumption and compressor durability

) Next-generation high performance premium compressors, engineered exclusively for Genius XE

) Smaller & quieter than previous generation of Genius

) On-board service scheduling and system diagnostics

) Additional compressor capacity for lower fl ow applications (XE 70 only)

On-demand nitrogen source for:

) LC-MS including new high-sensitivity instruments

) ELSD

) Small sample evaporators

) Other laboratory applications requiring nitrogen

Genius XE Nitrogen High performance nitrogen generator for LC-MS

710 mm / 28”570 mm / 22.5”

650

mm

/ 2

5.6

”10

00

mm

/ 3

9.4

Page 48: Solaris XE

Peak Scientifi c’s Quality Management System conforms to: ISO 9001:2015

Product CertificationsPeak Scientifi c UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientifi c North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide o� ce locations, please visit:www.peakscientifi c.com/o� ces

Web: www.peakscientifi c.comEmail: discover@peakscientifi c.com

Copyright 2020 Peak Scientifi c - Rev - Genius XE Data sheet Rev 7 RSID 2463 EN - 10/03/20

Technical Specifi cations Genius XE 35 Genius XE 70

Max Flow Rate up to 35 L/min up to 70 L/min

Max Pressure 116 psi (8 bar) 116 psi (8 bar)

Gas Outlets 1 x ¼” BSPP 1 x ¼” BSPP

Purity** 95-99.5% 95-99.5%

Max Relative Humidity 80% RH @ 31°C 80% RH @ 31°C

Max Altitude 3000m 3000m

Particles < 0.01 µm < 0.01 µm

Phthalates Phthalate & BHT Free Phthalate & BHT Free

Suspended Liquids None None

Non-Methane Hydrocarbon Content < 1 ppm NMHC < 1 ppm NMHC

Operating Temperature 5°C (41°F) to 35°C (95°F) 5°C (41°F) to 35°C (95°F)

Electrical Requirements 120VAC, 60Hz, 12A or 230VAC, 50/60Hz, 8A 230VAC, 50/60Hz, 11.3A

Power Consumption 960 VA (120V)/1265 VA (230V) 2530 VA

Heat Output 4118 BTU 8785 BTU

Noise Level† 56 dB 59 dB

Generator Dimensions (H x W x D) 650 x 570 x 710 mm25.6 x 22.5 x 28 ”

1000 x 570 x 710 mm39.4 x 22.5 x 28 ”

Generator Weight 92 kg / 202 lbs 147 kg / 325 lbs

Ordering Information

Part Number 3300252 (230VAC) /3300807 (120VAC) 3300253

Annual Servicevisit: www.peakscientifi c.com/ordering

Complete Maintenance Plan

** Factory certifi ed purity with respect to O2 content. Actual purity varies in relation to fl ow (min. 95% at maximum fl ow output)† Noise level expressed as SPL (Sound Pressure Level) measured at 1m from source in a reverberant chamber

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the

world, and come backed by a 2 year warranty*. Beyond this period however you can ensure that your investment continues to

be [Protected] by our comprehensive generator care cover.

Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you

the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a

breakdown.

*Year 2 of warranty subject to generator being serviced at end of year 1 by a Peak-approved agent in accordance with fi xed annual maintenance schedule.

For full terms and conditions visit www.peakscientifi c.com/warranty-statement

Page 49: Solaris XE

Your local gas generation partner

Service Kit :Part Number :

Key Features

Copyright 2015 Peak Scientific - Corona 1010 Data Sheet Rev 7 RSID 1287 EN - 10/10/19

Description

81-4000 08-9013

Applications

Corona 1010 Nitrogen Generator

) Suitable for applications requiring high purity nitrogen

) Available with or without external compressor module

) Dedicated solution for Thermo Scientific’s Corona and Vanquish instruments

) Tried and tested membrane technology delivers high purity nitrogen

) Gas is supplied on demand so generator works to your schedule

) The most cost-effective method of gas supply

) ThermoFisher Scientific Corona Veo

) ThermoFisher Scientific Vanquish CAD

Peak’s Corona 1010 model has been developed to meet the demands of labs requiring high purity nitrogen for their applications.

Suitable primarily for Charged Aerosol Detectors, the Corona 1010 generator delivers a high-purity, filtered nitrogen supply for applications requiring flows of up to 5l/min at 80psi.

With a space-saving design, the Corona 1010 can fit seamlessly into any laboratory. Engineered with an optional, dedicated compressor module for customers with no suitable supply of in-house compressed air, the Corona system provides a flexible solution for labs with differing configurations.

Corona 1010 shown in a stack with Corona Air Compressor.

156 mm

417 mm540 mm

406 mm

Page 50: Solaris XE

Peak Scientific UKTel: +44 (0)141 812 8100Fax: +44 (0)141 812 8200

Peak Scientific North America

Tel: +1 866 647 1649Fax: +1 978 608 9503

For a full list of our worldwide office locations, please visit:

Web: www.peakscientific.comEmail: [email protected]

Peak Scientific’s Quality Management System conforms to: ISO:9001:2008

Copyright 2015 Peak Scientific - Corona 1010 Data Sheet Rev 7 RSID 1287 EN - 10/10/19

Product Certifications

Peak Scientific gas generators define the benchmark in reliability, convenience and performance in laboratories around the world, and come backed by a 12 month warranty. Beyond this period however you can ensure that you’re investment continues to be [Protected] by our comprehensive generator care cover. Our world-class aftercare support packages deliver a program of scheduled preventative maintenance whilst giving you the reassurance of instant access to worldwide technical support and priority on-site response in the untimely event of a breakdown.

Technical Specifications Corona 1010

Max Flow Rate 5 lpm

Max Pressure 80 psi / 5.5 bar

Purity <2% 02 @ 5 L/min

Gas Outlets 1 x 1/4 " BSPP

Min Air Inlet Pressure 7.6 bar / 110 psi

Min Air Inlet Flow 30 lpm

Min Inlet Air Quality ISO8573 - 1:2010 Class 1.4.1

Phthalates None

Suspended Liquids None

Start-Up Time For Purity 5 minutes

Operating Temperature 5°C - 35°C / 41°F - 95 °F

Electrical Requirements 100-230V 50/60 HZ 0.01 A

Power Consumption 10 Watts

Heat Output Up to 140 BTU/Hr

Generator Dimensions (WxDxH) 156 x 417 x 540 mm /6.2 x 16.5 x 21.3’’

Generator Weight 12 Kg (26.5 lbs)

Ordering Information

Part Number 81-4000

Annual Service 08-9013

Standard Maintenance Plan 09 - 3110

Complete Maintenance Plan 09 - 3010

Corona Air Compressor 230V 110VPart Number 85-0555 85-1555

Annual Service 08-8352

Generator Dimensions (WxDxH) 406 x 417 x 540 mm / 16 x 16.5 x 21.3’’

Generator Weight 41.5 Kg (91.5 lbs)