SOLARE 1 · Solare 1 inverter is supplied with a pressure transducer; for a correct use the...
Transcript of SOLARE 1 · Solare 1 inverter is supplied with a pressure transducer; for a correct use the...
Catalogue 2017 OFFICINE DI TREVI
SOLARE 1
APPLICATIONSRaising clean water from deep wells in systems powered by solar energy.
FEATURESThe new system is composed of three elements: • photovoltaic panels (not included)• inverter• electric pumpSolare 1 inverter powers the elec-tric pump in sunshine, without sunthe system doesn’t work.Accumulators for electric power are not necessary because with this system the water is pumped and stocked during the day for an eventual use during the night.Solare 1 inverter is supplied with a pressure transducer; for a correct use the inverter must be supplied with voltage of 130 Vdc (max 15 A).Solare 1 inverter , right installed and calibrated, can stop the pump when the delivery outlet is closed, it is equipped with a dry running alarm and it stops the pump in case of excessive power consump-tion.The electric pump works with working voltage three-phase 230 V; in this way the absorptions are really limited.The electric pump is supplied with 30 m of H07RN-F electric cable.
OPERATING CONDITIONS• The inverter must be installed in a
protected and airy area.• Inverter working temperature: min
5°C – max 40°C.• Pumped liquid: clean water, non
aggressive, without solid particles.• The pump can not operate in dry
conditions.• Pump body always completely
submerged.• Temperature of pumped liquid:
min 5°C – max 30°C.• Vertical operating position.• Max immersion depth: 10 m.• Max number of starts per hour: 20.
OFFICINE DI TREVI Catalogue 2017
Solar kit
AkW
2,6
3,3
2,3
3,3
3,8
3,9
H
Kg
16,8
17,9
16
16,8
17,9
17,2
763
918
783
938
868
773
1,1
1,3
0,95
1,3
1,5
1,5
Electric pump Delivery
S1135-TE13
S1135-TE19
S1135-CR8
S1135-CR13
S1135-CR19
S1135-GA13
max currentInverter
Modelinput power
Model
H
POMPA INVERTERPump Inverter
The above mentioned data refer to the maximum water supply of the electric pump: with low energy generation, those values decrease till the stop of the system.
6,5
6,5
6,5
6,5
6,5
6,5
S1135-TE13
S1135-TE19
S1135-CR8
S1135-CR13
S1135-CR19
S1135-GA13
H/m
25
50
75
100
125
0
H/m
0
500
755
10000
1255
1000
H/m
50
25
75
25
50
75
100
125
H/m
l/min.
m /h3
10
0,6
20
1,2
30
1,8
40
2,4
50
3
60
3,6
70
4,2
80
4,8
90
5,4
100
6
010 20 30 40 50 60 l/min.
m /h33,632,41,81,20,6
0000 10 20 30
1,81,20,6
0 l/min.
m /h3
l// /mmmmmiinninnnnn..
mmm33
/hhhhh333
mm3333
H/mH/m
50
25
75