Solar Water Heating Systems Cataloge

7
SOLAR WATER HEATING SYSTEMS bringing solar to every home

Transcript of Solar Water Heating Systems Cataloge

Page 1: Solar Water Heating Systems Cataloge

SOLAR WATER HEATING SYSTEMS

bringing solar to every home

Page 2: Solar Water Heating Systems Cataloge

With cost and energy savings like never before, Honeywell solar water heatingsystems address heating requirements for varying family sizes, climatic conditions& building types. Besides, through a strong dealer network across country & welltrained installation team, the systems are easily accessible to end users, thus bringing solar to every home.

bringing solar to every Honeywell solar water heating system

Easy installation & maintenance features make the systems suitable for varied projects, right from bungalows, apartments to large townships, hotels, commercial and industrial buildings

Comes with Honeywell's repute in delivering innovation, comfort and energy efficiency in every day life

Durable and long life – life expectationof 15 years

Specially insulated storage tanks retain hot water for considerable amount of time, with minimal temperature drop at night and are suitable for Indian hard water conditions

Compact and sleek design of the system adds to aesthetics

02

15

Page 3: Solar Water Heating Systems Cataloge

homeHoneywell solar water heaters work on thermosiphon principle, a highly trusted and efficient system of water heating. Based on phenomenon of natural convection, water stored in the collector heats up by solar energy, becomes lighter and rises naturally into the tank above. At the same time the cooler water in the tank flows down the pipe to bottom of the collector, and this circulation continues to occur naturally, resulting in overall temperature rise of water stored in the tank.

the thermosiphon principle

We can provide customization services from 80L to 300L according your request

the standard system specificationsItem Specs CA47-1515 CA47-1530 CA58-1820 CA58-1830Capacity 100L 200L 200L 300LInner Tank Diameter: φ 350mm, Material: Stainless Steel Diameter:φ 370mm, Material: Stainless Steel

SUS304-2B, Thickness: δ = 0.5mm SUS304-2B, Thickness: δ = 0.5mmOuter Tank Diameter: φ 450mm, Material: Painted Steel Plate, Diameter:φ 472mm, Material: Painted Steel Plate,

Thickness: δ = 0.376mm Thickness: δ = 0.426mmInsulation Polyurethane foaming 141B δ = 50mm Polyurethane foaming 141B δ = 50mmAnode Protection Not Included Included Mg Protective RodBrackets Aluminium alloyReflector No ReflectorInclination 42/30 DegreeWelding Automatic Argon-arc and seamless weldingEvacuated Tube Blue Tubes, Dimension: φ 47x1500mm Blue Tubes, dimension: φ 58 x 1800mmQty in 20ft/40ft/40hc 60/128/142 33 / 74 / 82 30 / 64 / 70 18 / 44 / 48

Solar water heating technology is fast emerging as the most energy -efficient and inexpensive method of water heating and perhaps the only solution to today's challenge of increasing energy costs, rising pollution levels and rapidly depleting energy sources.

Cold Water

Hot Water

Warm Water

types of solar water heating systems

open loopcollector system

evacuated tube cpccollector system

03

stand alonesystem

Page 4: Solar Water Heating Systems Cataloge

technology advantageThe solar collector comprises evacuated tubes that are optimized in geometry and performance. These tubes are constructed from two concentric glass tubes, half spherically closed on one side & fused together on the other side; the gap between them is evacuated & afterwards hermetically plugged (vacuum insulation).

The internal glass tube has a highly selective & eco friendly aluminum nitrite sputter layer on its external surface, that acts as an absorber, to effectively capture solar power.

Evacuated tube specificationsItem Specification Target

Absorbance Rate after Coating (AM 1.5) α ≥ 94.5%Absorbance Rate after Evacuating (AM!.5) α ≥ 93.5%Emission Rate after Coating (80+ 50C ) ε ≤ 6.0%Emission Rate after Evacuating (80+ 50C ) ε ≤ 6.5%

2Stagnation Parameter ≥ 240m C/KW2Solar Radiance Exposure ≤ 3.0MJ/ m2Average Heat Loss Coefficient ≤ 0.70W/(m.0C)

Selective Coating Material SS-Al-N/CuImpact Resistance Steel Ball Test: Steel ball with diameter of 30mm fall

on the evacuated tube vertically from 450mm height, the evacuated tube is not damaged

Coating No besmirching, crusting or flaking off.Coating Lighter Area The coating colour shall be even, with

lighter area shall be smaller than 50mmVaccum Degree ≤ 3 x 10 -3PAPressure 0.6MPaTransparent ≥ 0.89 (AM1.51S09806-1: 1994

1. Metal Insulation Layer (Copper)Reduce heat loss and low dow emission rate

2. Absorption Layer (Stainless Steel & AI-N-AI Enameled Mirror)Anti -corrosion & Anti-oxidation

3. Anti-reflection Layer (AI-N-AI)Ensure high absorption rate & low emission rate by reducing reflection

the evacuated tubes

1. Inner tube2. Solar Selective Absorption Coating3. Vaccum Gap4. Outer tube5. Supporter6. Getter7. Absorption film

1 2 3 4 5 6 7

L

D d

S

04

Page 5: Solar Water Heating Systems Cataloge

centralized system

Specifications LPC47-1525 LPC47-1550Head Box Inner Tank SUS304-2B δ 0.6mmHead Box Outer Tank Aluminum AlloyInsulation Thickness 45mm (PUF)Structure Inlet/Outlet, different sides of the Head BoxSide and Bottom Frames Aluminium AlloyHead Box and Frames are Packed 1935*215*265mm 1935*215*265mmtogether in one Carton BoxEvacuated tube Single Target φ47x 1500mmDistance between each two tubes 70mmNos of Tubes 25 Pieces 50 PiecesEvacuated Tubes are seperately packed (15pc/carbon) 1580*280*200mmGrid measurements (length, height, depth) 1650 x 1980 x 185mm 3230 x 1980x 185mmMax working pressure bar 0.05MPa

0Max stagnation temperature0C 95 CConnection diameter of inlet and outlet tube 27mm

2 2Aperture Area 2.4m 4.82m

Open Loop collector systems are ideal for large scale heating requirements such as in hotels, swimming pools and sports center, where hot water is required round-the-clock.

This is an open loop system where heating occurs via natural circulation process through non pressurized collectors, transferring hot water to large storage tanks for further use

=Easy to install, cost- effective systems

=Installations done by well-trained team with experience in large projects

=Blends well with building aesthetics

=Can be incorporated with different kinds of control systems, depending on requirement

specifications

Open Loop Collector System

05

Page 6: Solar Water Heating Systems Cataloge

Evacuated tube collector systems cater to domestic water heating requirements. Heating occurs in a continuous copper loop with one time heat exchange These are fully pre-mounted units comprising CPC (compund parabolic concentrated collector) reflector and evacuated tubes with an additional protection sheet for better performance .

SERIES Unit CPC 1506 CPC 1512 CPC 1518 U1521Number of evacuated tubes 6 12 18 21ηo (Aperture), DIN 4757-4 or EN 12975 % 64.2 64.2 64.2 74.5

2 2C with wind, in relation to aperture W/(mk) 0.89 0.89 0.89 2.0071

2 2C with wind, in relation to aperture W/(m k) 0.001 0.001 0.001 0.0052

2) 2Yield forecast (ref area 3m kWh/ma 651 651 651 7802) 2Yield forecast (ref area 5m kWh/ma 589 589 589 619

Grid dimension (length x height x depth) m 0.70x 1.64 x 0.1 1.39x1.64x 0.1 2.08x 1.64x 0.1 1.45X 1.64 X 0.102Gross surface area m 1.15 2.28 3.41 2.322Aperture area m 1.0 2.0 3.0 1.33

Collector contents | 0.8 1.6 2.4 2.5Weight kg 19 37 54 51Max. Working overpressure bar 10 10 10 10

0Max. Stagnation temperature C 295 295 295 220Connection diameter, clamping ring mm 15 15 15 15Sensor sleeve mm 6 6 6 6Collector material A| / Cu / glass/ silicon /PBT /EPDM TE Al/Cu/glass/silicon/PBT/EPDM/TEGlass tube material borosilicate glass 3.3 borosilicate glass 3.3Selective absorber coating material aluminium nitrite aluminium nitriteGlass tube (φ ext. /φ int../wall thickness/tube len.) mm 47/37/1.6/1500 47/37/1.6/1500Colour (aluminium frame profile, anodised) aluminium grey aluminium greyColour (plastic parts) black blackThermal shock test ITW test no.02COL282 ITW test no.02COL282Hailstone test according to DIN EN 12975-2 TUV test no.435/142448 TUV test no.435/142448EC Type examination Z-DDK-MUC-04-100029919-005 Z-DDK-MUC-07-08-100029919-003DIN CERTCO - Register number 011-7S113R 011-7S114R

specifications

=Easy to install, cost- effective systems

=Suitable for medium to high temperature requirements ranging from 50ºC - 130ºC

=Heat transfer fluid can be water, glycol or a mixture of both

=Mounting can be on slanting roof/ flat roof with a minimum angle of 15º

Evacuated Tube CPC Collector System

centralized system

06

Page 7: Solar Water Heating Systems Cataloge

project gallery

Solar Water Heating Systems are suitable for varied projects right from bungalows, villas, apartments to large townships, hotels, commercial and industrial buildings.