Solar Sipper Presentation

12
2650 East 40 th Avenue • Denver, Colorado 80205 • www.geotechenv.com GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS Geotech Environmental Equipment, Inc. Solar Sipper Presentation Green Remediation Technology

Transcript of Solar Sipper Presentation

Page 1: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

GeotechEnvironmental Equipment, Inc.

Solar Sipper Presentation Green Remediation

Technology

Page 2: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Installation Diagram

Page 3: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Solar Sipper

• No need for electrical service installation

• Can move around from well to well very easily

• Can be used for emergency response

• Saves time and money

• Reduces overall carbon footprint

• One controller can operate up to eight pumps in recovery

wells

Page 4: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Page 5: Solar Sipper Presentation
Page 6: Solar Sipper Presentation

Depth to Fluid (feet)Airline Length (feet)

Product Viscosity

Product Recharge Rate (GPH)

Vacuum Time (mm:ss)

Pressure Time (mm:ss)

Delay Time(hh:mm:ss)

Expected Daily 8 hours Recovery (US Gallons) KWH

8 Hours 65W Panel 75 AH Combo % Capacity

8 Hours 130W Panel(s) 75 AH Combo % Capacity

10 25 Light 1 0:00:15 0:00:30 0:11:00 8 0.006 10% 5%

10 25 Light 2 0:00:15 0:00:30 0:05:00 16 0.013 20% 10%

10 25 Light 4 0:00:15 0:00:30 0:02:30 32 0.023 35% 18%

10 25 Light 8 0:00:15 0:00:30 0:01:15 64 0.038 58% 29%

10 25 Light 16 0:00:15 0:00:30 0:00:37 128 0.055 84% 42%

10 25 Light 32 0:00:15 0:00:30 0:00:20 256 0.069 106% 53%

0 25 Medium 1 0:00:30 0:01:00 0:11:00 8 0.012 18% 9%

10 25 Medium 2 0:00:30 0:01:00 0:05:00 16 0.023 35% 18%

10 25 Medium 4 0:00:30 0:01:00 0:02:30 32 0.038 58% 29%

10 25 Medium 8 0:00:30 0:01:00 0:01:15 64 0.055 84% 42%

10 25 Medium 16 0:00:30 0:01:00 0:00:37 128 0.071 109% 54%

10 25 Heavy 1 0:01:30 0:03:00 0:11:00 8 0.029 45% 22%

10 25 Heavy 2 0:01:30 0:03:00 0:05:00 16 0.047 72% 36%

10 25 Heavy 4 0:01:30 0:03:00 0:02:30 32 0.064 99%49%

Page 7: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Geotech Solar Sipper Advantages

• Green Technology: Electrical power used to run the Solar Sipper is generated on-site by solar panels, sparing approximately 0.15 pounds of CO2 per hour of continuous operation from the

atmosphere, based on the national average coal fired power plant efficiencies. In addition, O&M activities are reduced, due to the systems simplicity, resulting in less site visits, thereby reducing the amount of CO2 entering the atmosphere from maintenance staff

vehicles.

• For sites where electricity is not available or economically available

• Compact Footprint

Page 8: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Geotech Solar Sipper Advantages Continued:

• Recovers virtually water–free hydrocarbons through the use of an oleophilic/hydrophobic floating intake cartridge skimmer assembly

• No expensive compressed air bottles required, unit provides it’s own air to operate the built-in compressor/vacuum pump

• Can recover higher viscosity hydrocarbon when configured with a heavy oil intake cartridge

• Can recover DNAPL with fixed intake assembly • Available for 2'' and 4'' wells

Page 9: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Solar Sipper Specifications

• 2'' (5.8 cm) or larger recovery wells

• Recovery rate: 0.2 gallons (.750 ml) per cycle (Larger canister__per cycle)

• Maximum Operating depth: 180 ft. (54.86 m)

• Power requirements: (As low as) 12-15 volts DC input @ 7.5 Amps 90-105 Watts usage

• Maximum Vacuum: 20'' HgV @ MSL

• Maximum Pressure: 100 PSIG

• Oil/Water Separation: Oleophilic/Hydrophobic mesh screen intake

• Single Solar Panel: 64 Watt, 16.5 operating voltage

Page 10: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Single Well Configuration• NEMA 4 Enclosure

• 64 Watt Solar Panel with Adjustable Mounting Frame

• Tankfull Shut Switch ( 2'' & ¾'' bung–fitting)

• Microprocessor Controller with alpha-numeric vacuum fluorescent display

• On/Off Switch

• Pressure/Vacuum Pump

• Pressure/Vacuum Gauge

• 2'' or 4'' Intake

• Down-Well Collection Canister

• 2'' or 4'' Slip Fit Well Cap

• 100' of Air & Discharge Tubing

Page 11: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

Options

• Multi-Channel Controller to recover from up to 8 recovery wells

• 55 Gallon Steel Product Drum

• Dual Containment Product Tank

• AGM Solar Battery

• Wall or Pole Mount Kit

• Trailer Mounted Configuration

• Can be configured with multiple batteries and panels to meet

the power demand for site location, hydrocarbon type, and

recharge rate

• Additional Accessories Available

Page 12: Solar Sipper Presentation

2650 East 40th Avenue • Denver, Colorado 80205 • www.geotechenv.com

GROUND WATER SAMPLING • WATER LEVEL & PRESSURE • WATER SAMPLE FILTRATION • GROUND WATER REMEDIATION • GEOPHYSICAL MEASUREMENTS

What sites do you have where this might be applicable?

Call Geotech 800-833-7974