Solar Lighting Systems - hapsr.comhapsr.com/HAP solar.pdf · PWM solar charge controller, pure sine...
Transcript of Solar Lighting Systems - hapsr.comhapsr.com/HAP solar.pdf · PWM solar charge controller, pure sine...
Solar Lighting Systems
USOLAR PS
SOLAR
SOLAR PANEL
CHARGE CONTROLLER
MODELS
SOLAR POWER CONDITIONING UNITS (Rating 800W - 20KW)
OUR OTHER PRODUCTS
Save Earth a word everybody utter, to save the nature for feature generation. In India we have
Ample Nature resource compered to others. We utilize the sun power.
We at Hap took a challenge to make solar energy harvesting to be affordable. We are solar PCU
manufactures to offer a most reliable, most trusted, most efficient and feature rich Solar PCU
with pure sine wave output.
We can provide you the Solar PCU's with standard specifications or customized solution to meet
your needs.
Mono & Poly Crystalline, High efficiency export quality
products. Life of Solar Panel 25 Years.
Hap solar Charge controller is a DSP based system with three
stage charging process. We have Series PWM charge controllers.
12V - 96V / 6A - 60Amps Series Regulator - PWM charge controller
Street Light Charge Controller with Automatic Dusk to Dawn (DTDC) operation
The Solar power Conditioning unit - shortly known as PCU is an integrated system consisting of
PWM solar charge controller, pure sine wave Inverter and grid charger.
Solar Power Plant, Solar Street Light, Solar Lantern, Solar Home UPS
Solar Water Heater & Etc.,
F
F
Capacity VA/Watt 800VA/640W 1000VA/800W 2000VA/1600W 3000VA/2400W 5KVA/20KVA
Battery VDC 12VDC 12/24/36/48VDC 24/36/48VDC 36/48VDC 96V-360VDC
Inbuilt Solar Charge Controller
Nominal Output Voltage 220/230/240VAC
User Selectable Mode UPS (for Computer Applications) Optional/Wide Mode (Iighting Applications
Acceptable Voltage Range 180-260V (For UPS mode) 120-290VAC (For wide mode)
Frequency
40Hz -53Hz
InputVoltage
Low Voltage Transfer
Range Low Voltage Return
High Voltage Transfer
High Voltage Return
Freq.reg.
Output
Efficiency
Overload Protection Line Mode
Battery Mode
Short Circuit Protection Line Mode
Battery Mode
With both mains power plant presentSolar
and solar present (Power save mode)Inverter
Hybrid
mode
Solar
Charger
DC Start
Transfer Time
Battery
LED Display
LCD Display I/P Volt, O/P Volt, Load %, Solar Current, Battery Volt
Protection Feature Battery Low / High / Over charge , Over load, Over Temperature, short Circuit, Phase reverse / Battery reverse - DC fuse fails on PCB
Parameter Re-settable Output voltage, Charging Current, Battery Boost Voltage
Physical Dimensions (W x H x D) mm
Net weight (Kgs)
Inverter Fault, Phase reversal, Short Circuit
Backup Time
Charging Current
Depends on batteries connected (Max Battery Capacity recommended upto 200Ah)
upto 12A-Mains utility power/Solar charging current depends on Panel wattage
Solar IN,Mains ON,Inverter ON, Charged/ Charging, Battery Low, Over Load, Over Temperature,
Dual Mode (with mode switch Down) Charges both from Mains utility power and Solar (charging LED blink)
Cold start (with Load) Yes
Typical <6ms (for Home UPS mode);<6ms (for wide range mode)
With Mains Power present and Solar Absent Returns to mains utility power and charges battery using Mains utility power
Solar prefer mode (with mode Switch TOP) Only charges through solar when solar present ,if Solar absent then charges through utility power
Battery fully Charged Automatic Charge over to Backup mode and runs on solar,if solarnot sufficient excess is taken from the battery until battery discharge below 11.95
Battery discharge below
11.95V
Returns to mains utility power and charges the battery using only Solar.When again
the battery is fully charged -repeats above function
PWM CHARGE CONTROLLER
180VAC ± 5V(For UPS mode) 120VAC ± 5V(For wide range mode)
190VAC ± 5V(For UPS mode) 130VAC ± 5V(For wide range mode)
260VAC ± 5V(For UPS mode) 290VAC ± 5V(For wide range mode)
250VAC ± 5V(For UPS mode) 283VAC ± 5V(For wide range mode)
Wave Form
Line Mode
Battery Mode
Follows input
220 Nominal
same as AC Mains Input
0.8
Voltage Regulation Mains Mode
Voltage Regulation in Battery mode
Power Factor
FUSE
Electronic Shutdown
50Hz ± 0.1Hz
Pure Sine Wave
Inline Fuse Protected
110%-120% for 10sec;>120%for 200ms,Retry for 4 times then Inverter Shuts Down
upto 92%(dependent on System VDC and Load)
The Technical specifications are subjected to change without prior notice for the further improvement in products
79-D, Vasantha Mill Road, Near Palaniyappa Complex, SinganallurCoimbatore - 641 005. Ph : 0422 - 6556018, Cell : 90954 41801E-mail : Web : [email protected] www.hapsr.com
S.R. ENTERPRISES Dealer