![Page 1: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/1.jpg)
Smartflowerproduct version for North America
TECHNICAL DATASHEET
![Page 2: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/2.jpg)
TECHNICAL DATA
POWER OUTPUT INSTALLATIONNominal output 2.5 kWp* 4 fastening pointsOutput through 2-axle tracking Assembly with earth screws or concrete foundation
SYSTEM APPLICATION AREA
Panel Type Glass/ Backsheet Temperature range -4°F to 122°F
Panel Power Output Warranty 25 years at ≥ 80% Humidity 0-95% (non condensing)Panel Product Warranty 10 years Maximum altitude 6561 ftCell type monocrystalline Maximum sound pressure level <50 dB (A) outside active zone Inverter Module on-grid, 1-phase, integratedInverter Module Warranty 10 years ELECTRICAL CONNECTIONS
Weight 1521lb Up to 98 ft 5 x AWG 12 (4 mm²)(0.04 x 0.16 inch²)
System Warranty 5 years, with maintenance From 98 ft onwards Local standards must be followed
System self-consumption per year approx.< 100 kWh The grid connection must be secured with 20A (alternatively 16A) circuit breaker.Windguard incl. 32 ft cable length.Network/LAN cable recommended (CAT6e or CAT7), RJ45 connector.
DIMENSIONS FIXING POINTS/ ORIENTATION
* under STC ** depending on the region
Agency Approval UL3703, UL1703,UL1004, CSA, FCC Class B
Drilling templates for earth screws may be purchased through Smartflower North America
![Page 3: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/3.jpg)
6" CELL CONFIGURATION PANEL 2-11
6" CELL CONFIGURATION PANEL 12
All values are average values, measured at STC.All panels are assembled with standard glass backsheet technology. Front is faced with tempered glass of 2.1 mm.
MODULE MANUFACTURER
6" CELL CONFIGURATION PANEL 1
Energetica Energietechnik GmbH
Adi-Dassler-Gasse 6, 9073 Klagenfurt-Viktring, Austria
SMARTFLOWER
PANEL 1Nominal power Pmpp 225 WpOpen circuit voltage Uoc 32.17 VNominal voltage Umpp 25.83 VNominal current Impp 8.73 AShort circuit current Isc 9.12 AMaximum power tolerance *+/-5%
Current temperature coefficient (Isc) 0.04 %/° CVoltage temperature coefficient (Uoc) -0.32 %/° CPower temperature coefficient (Pmpp) -0.40%/°CNOCT 44° CCells 49 monocrystalline solar cellsCell-dimensionsBypass diodes (per module) 3Connector type & cables H4 connector, 1 x 4 mm2 (0.04 x 0.16 inch²)
Ambient temperature range ´-13°F - +185°FMax. system voltage UL 750 VdcSerial fuse rating 10A
SMARTFLOWER PANELS 2-11
Nominal power Pmpp 215 WpOpen circuit voltage Uoc 28.96 VNominal voltage Umpp 23.96 VNominal current Impp 8.94 AShort circuit current Isc 9.27 AMaximum power tolerance *+/-5%
Current temperature coefficient (Isc) 0.04 %/° CVoltage temperature coefficient (Uoc) -0.32 %/° CPower temperature coefficient (Pmpp) -0.40%/°CNOCT 44° CCells 44 monocrystalline solar cellsCell-dimensionsBypass diodes (per module) 2
Connector type & cables H4 connector, 1 x 4 mm2 (0.04 x 0.16 inch2)
Ambient temperature range ´-13°F - +185°F
Max. system voltage UL 750 VdcSerial fuse rating 10A
SMARTFLOWER PANEL 12
Nominal power Pmpp 155 WpOpen circuit voltage Uoc 21.96 VNominal voltage Umpp 17.20 VNominal current Impp 8.94 AShort circuit current Isc 9.30 AMaximum power tolerance *+/- 5%
Current temperature coefficient (Isc) 0.04 %/°CVoltage temperature coefficient (Uoc) -0.32 %/°CPower temperature coefficient (Pmpp) -0.40%/°CNOCT 44 °CCells 33 monocrystalline solar cellsCell-dimensionsBypass diodes (per module) 2Connector type & cables H4 connector, 1 x 4 mm² (0.04 x 0.16 inch2)
Ambient temperature range ´-13°F - +185°F
Max. system voltage UL 750 VdcSerial fuse rating 10A
Energetica Energietechnik GmbH
Adi-Dassler-Gasse 6, 9073 Klagenfurt-Viktring, Austria
SMARTFLOWER
![Page 4: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/4.jpg)
INVERTER DATA
Inverter
Country application
DC Input Data
Max. PV-generator power
Max. DC voltage
MPPT voltage range
Max. DC work current
Number of inputs/Mpp trackers
AC output Data
Rated AC power
Max. AC current
Power factor (cos g)
AC connection
Grid Voltage Range
Grid Frequency Range
Feed-in phases
Max. efficiency
CEC efficiency
MPPT-efficiency
Safety equipment
Residual Current Monitoring Unit (RCMU)
Grid monitoring with Anti-islanding yes
DC reverse polarity protection yes
DC switch for each MPPT yes
Output over current protection yes
Output overvoltage protection-varistor yes
Ground fault monitoring yes
Grid monitoring yes
Integrated all-pole sensitive yes
leakage current monitoring unit
Normative references
Applicable standards
General Data
Operative temperature rangeRelative humidity
Enclosure rating
Topology
Warranty
For more information data sheet: www.growatt.com
1
on-grid (240 V split-phase, L1, L2, N, PE)
211-264 V (@ 240 V split-phase)
2800 W (@ 240 V splitphase)
1/117 A
120-450 V (start voltage 150 V)
500 V
14.2 A (@ 240 V)
type 3R
transformerless
10 years
0-100%
3200 W
North America
-13/+140° F
97.5%
96.5%
99.5%
yes
UL 1741, UL 1998, IEEE 1547, CSA C22.2 NO 107.1-4, FCC Part 15 (A8B)
59.3-60.5 Hz
GROWATT 3000 TL-US
![Page 5: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/5.jpg)
![Page 6: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/6.jpg)
![Page 7: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/7.jpg)
![Page 8: solar energy made attractive - TECHNICAL DATASHEET...2017/01/02 · Inverter Module on-grid, 1-phase, integrated Inverter Module Warranty 10 years ELECTRICAL CONNECTIONS Weight 1521lb](https://reader036.fdocuments.in/reader036/viewer/2022081620/610299f38e519858ba05137c/html5/thumbnails/8.jpg)