SOCORE - GRA C

41
S ustained O xidation and C ontrolled O xidant R elease E ncapsulants SOCORE Dr. Lindsay Swearingen Principal Scientist Specialty Earth Sciences

Transcript of SOCORE - GRA C

Page 1: SOCORE - GRA C

Sustained Oxidation and Controlled Oxidant Release

Encapsulants

SOCORE

Dr. Lindsay SwearingenPrincipal Scientist

Specialty Earth Sciences

Page 2: SOCORE - GRA C

Traditional ISCO

Overview

Page 3: SOCORE - GRA C

ADVANTAGES

• Accelerated Treatment (weeks to months)

• Temporary Set-Up

• Obtainable MCL’s

• Effective on many recalcitrant compounds.

ISCO Overview:DISADVANTAGES

• Requires Larger Up Front Capital Cost to Get Faster Cleanup

• Involves Handling of Powerful Oxidants.

• Cumbersome and disruptive site logistics

• Ineffective and dangerous when implemented by inexperienced personnel.

Page 4: SOCORE - GRA C

Encapsulated ReactantsWhat are the Methods

and Materials?

Page 5: SOCORE - GRA C

Independently researched and published by several universities including:

Ohio State, Purdue, University of Nebraska, Clemson, Colorado School of Mines, UNC A&T,

and Clarkson University

Currently the subject of DOD/DOE field study: ESTCP Proj# ER-201324 - “Sustained In Situ

Chemical Oxidation (ISCO) of 1,4-Dioxane Using Slow Release Chemical Oxidant Cylinders”

3rd Party Validation

Page 6: SOCORE - GRA C

References:

Links to 3rd party publications can also

be found on our website at:

www.sesciences.com/technical-library

Page 7: SOCORE - GRA C

Key Concepts:

CONTROL IMPLEMENTATION COSTS:

• No expensive injection field services required

• Use your preferred driller• Implementation can be achieved by on-

site consultant CONTROL REACTANT DISTRIBUTION:

• Apply reactants where they belong without guessing where chemical is going

• Apply reactants in sufficient mass required (Ex: 500 lbs oxidant in 10’x10” auger boring)

Page 8: SOCORE - GRA C

• Safer and more effective approach to ISCO

• Delivers high concentration reactants to the target and remains active for longer periods of time (several months to a couple of years – depending on material selection)

• Addresses the common problems and technical challenges encountered with traditional pressurized liquid injection applications:

Technology

1. Relatively short period of oxidant activity in subsurface

2. Contaminant contact problems - injected oxidants take the path of least resistance (flow-by)

3. Problem geologies: low permeable media (LPM)

4. Site logistics – ISCO events are cumbersome and can be disruptive to active facilities

Page 9: SOCORE - GRA C

• Involves coating or encapsulating granular environmental reactants for a more efficient and user-friendlyimplementation

• These materials can be applied to the subsurface in a number of forms and methods……..

Technology

MULTIPLE SHAPES

MULTIPLE SIZES

SEVERAL CHEMISTRIES

Page 10: SOCORE - GRA C

• Cylinders

• Spheres

• Granules

• Pellets

Material Forms

Page 11: SOCORE - GRA C

Horizontal WellsDirect Borehole

Installation Excavation Closure

Down-Well Installation

Installation Methods

Page 12: SOCORE - GRA C

1) Sustained Reactant Release

2) Targeted Reactant Release

MechanismOf

ReactantRelease

***Slow/sustained reactant release over time is the prevailing MRR in dissolved phase contaminant conditions***

• In the presence of NAPL reactants will be preferentially released in high concentration

• Targeted release is governed by the effects of hydrocarbon partitioning

Page 13: SOCORE - GRA C

Transport Kinetics

1. Advective flow governs reactant transport in transmissive formations

2. Concentration gradient driven diffusion governs transport in low permeability, perched formations

Page 14: SOCORE - GRA C

Groundwater contamination

Page 15: SOCORE - GRA C

Plume migration

Page 16: SOCORE - GRA C

Further plume migration

Page 17: SOCORE - GRA C

…….and further

Page 18: SOCORE - GRA C

SOCORE – borehole/DPT/auger installation

Page 19: SOCORE - GRA C

SOCORE – well installation

Page 20: SOCORE - GRA C

SOCORE – horizontal well/DD-PRB installation

Page 21: SOCORE - GRA C

SOCORE – reactant release and distribution

Page 22: SOCORE - GRA C

SOCORE – reactant release and distribution continued

Page 23: SOCORE - GRA C

SOCORE – reactant release and distribution continued….

Page 24: SOCORE - GRA C

SOCORE – reactive zone established

Page 25: SOCORE - GRA C

Plume reduction/interception

Page 26: SOCORE - GRA C

Site Selection – When and where is SOCORE an appropriate remedial approach?

• Reactive Treatment/Interceptor Zones

• Saturated Conditions (not a vadose zone technology)

• Active facilities or remote locations where minimal remedial infrastructure is desired

• Heterogeneous formations and LPM where back diffusion would otherwise be problematic in a liquid application

• Remember stoichiometry – don’t under-dose the application….there is no magical chemistry

Page 27: SOCORE - GRA C

CASE STUDY #1

(California)

Page 28: SOCORE - GRA C

Reactive Interceptor

Zone

Background:

GW Flow

•Geology – stratified layers of bay mudsand silty sands to 35’ bgs, underlain by sands and silty sands

•Impacted interval - 10’-40’ bgs•COC – CVOC’s in GW migrating from up-gradient source (primarily PCE)

•10,000 ug/L baseline at PMP’s•Goal – mitigate further down-gradient plume migration

•51 boreholes –1. Top down permanganate

injection2. completed with 2” piezometers

for SOCORE deployment (459 total - 1.35” x 24” SOCORE Permanganate Cylinders)

•3 (dual-nested) performance monitoring piezometers (PMP’s)•5 permanganate obs piezometers (POP’s)

PMP-1S/1D

PMP-2S/2D

PMP-3S/3D

Page 29: SOCORE - GRA C

Site Photos:

Page 30: SOCORE - GRA C

Site Photos:

Page 31: SOCORE - GRA C

Results: PMP 1

In-well mixing added – at 4 SOCORE wells up-gradient to PMP 1 and PMP 2

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

PMP-1S

PMP-1DPCE in GW

(ug/L)

PMP 1S/1D – Monitoring Data

Spring 2015 Implementation

• Rapid PCE reduction observed in deep zone (PMP-1D)• Shallow zone (PMP-1S) was less responsive to initial efforts• In-well mixing was added at 4 SOCORE wells to improve vertical

distribution of oxidant across the 20+ ft SOCORE well screen• Subsequent reduction in PCE was then observed in shallow zone

Page 32: SOCORE - GRA C

Results: PMP 2

In-well mixing

0

2000

4000

6000

8000

10000

12000

PMP-2S

PMP-2DPCE in GW

(ug/L)

PMP 2S/2D – Monitoring Data

Spring 2015 Implementation

• Similar improvement in shallow zone response was seen at PMP-2 after in-well mixing was added

Page 33: SOCORE - GRA C

Results: PMP 3

0

500

1000

1500

2000

2500

3000

3500

4000

4500

PMP-3S

PMP-3DPCE in GW

(ug/L)

• The system was installed in Spring 2015 at a cost of $350,000 (including drilling, permitting, and reporting)• PCE concentrations at shallow performance monitoring are decreasing• 2 years after remedial implementation:

• SOCORE Permanganate re-charge event is now due

PMP 3S/3D – Monitoring Data

Spring 2015 Implementation

Page 34: SOCORE - GRA C

CASE STUDY #2

(New Jersey)

Page 35: SOCORE - GRA C

Site logistics: • Active industrial facility• Remaining source zone soils are

located at building foundation and adjacent to sewer utilities

• Source remains in place

Previous remediation activities - extensive Free Product Recovery activities and limited source excavation, 2 RegenOx injections

Client’s goals - seeking cost-effective and low-impact remedial strategy to address source area groundwater

COC’s - PCE, TCE, DCE, VC in GW (100,000+ug/L total targeted CVOC in GW at source zone target well)

Geology - impacted fill to 10-12’ bgs, underlain by LPM clay formationLow-Cost,

Low-Maintenance,

and Green Reactive

Treatment Zone

Background:

Target MW

Page 36: SOCORE - GRA C

Low-Cost, Low-

Maintenance, and Green Reactive

Treatment Zone

Background:

This was the extent of our site access =10 x 35 ft

Target well for assessing treatment zone

Page 37: SOCORE - GRA C

SOCORE – Each DPT borehole was completed with 2” ID PVC 3-Step Implementation

Remedial Approach:

1) Injection

• 10 DPT boreholes• Top down injection from 4’-10’ bgs• 40 gal of 10% NaMnO4 per

borehole from 4’-10’ bgs• followed by 25 gallon chase

injections of clean water to assist distribution

• DPT boreholes placed on 3-foot spacings in a single row

2) SOCORE –

• each borehole completed with 2” ID PVC piezometer

• screened from 2’-12” bgs(target interval)

• 4 SOCORE Permanganate cylinders with holders were deployed from 2’ -12’ bgs at each

• Total of 40 SOCORE Permanganate cylinders (1.35” x 24”)

3) Recirculation –

• To accelerate KMnO4 mixing/distribution across the reactive interceptor zone

• low-flow solar-powered recirculation system was also installed

• including: piston pump, manifolds, solenoid valves, programmable timer, and re-circulation lines.

Page 38: SOCORE - GRA C

Low-Cost, Low-

Maintenance and, Green Reactive

Interceptor Zone

Results: • The system was installed in June 2013 at a cost of less than $75,000.

• VOC concentrations decreased at target monitoring well as expected

• 2.5 years after remedial implementation:

• rising VOC concentrations• decreasing Mn concentrations• SOCORE Permanganate re-

charge event was due

• The first SOCORE material re-charge event was performed in August 2016 for less than $10,000.

0

20,000

40,000

60,000

80,000

100,000

120,000

140,000

6/1/

12

9/1/

12

12/1

/12

3/1/

13

6/1/

13

9/1/

13

12/1

/13

3/1/

14

6/1/

14

9/1/

14

12/1

/14

3/1/

15

6/1/

15

9/1/

15

12/1

/15

3/1/

16

6/1/

16

9/1/

16

Total Targeted VOCs ug/L:

0

200

400

600

800

1,000

1,200

6/1/

12

9/1/

12

12/1

/12

3/1/

13

6/1/

13

9/1/

13

12/1

/13

3/1/

14

6/1/

14

9/1/

14

12/1

/14

3/1/

15

6/1/

15

9/1/

15

12/1

/15

3/1/

16

6/1/

16

9/1/

16

Manganese ug/L

ImplementationSOCORE

DepletionRecharge

Event

June 2013 Sept 2015 Aug 2016

Dec 2016 – Targeted VOC’s down to 12,000 ug/L from 45,000 ug/L

Page 39: SOCORE - GRA C

Technical Pearls:1. Safer and more efficient approach to ISCO

2. Targeted delivery of high concentration reactants

3. Reactive zones and interceptors

4. Addresses problems and challenges encountered with liquid injections

5. Cost to completion less than traditional ISCO injection

6. Implementation by on-site consultant

Page 40: SOCORE - GRA C

References:

Links to 3rd party publications can also

be found on our website at:

www.sesciences.com/technical-library

Page 41: SOCORE - GRA C

CONTACT:Dr. Lindsay Swearingen

Principal Scientist/Managing PartnerSpecialty Earth Sciences, LLC

[email protected]

812-945-0733

Headquarters:New Albany, IN

(Louisville)

Midwest:Fishers, IN

(Indianapolis)

West Coast:Huntington Beach, CA

(Orange County)

East Coast:Middletown, VA