Smok & Heat
description
Transcript of Smok & Heat
Order Catalogue
RWA and ventilation systems
Chain drives Spindle drives / Rack and pinion drives
Door opening actuator Locking actuators
RWA opening systems Fanlight opening systems Control centres Accessories
Edition 12.2009
3Edition 12.2009
Introduction
RWA systems
Smoke extraction and ventilation installations for staircases . . . . . . . . . 4
Smoke exhaust to EN 12101-2 (SHEV) . . . . . . . . . . . . . . . . . . . . . . . . . . 5
RWA system layout /
Selection criteria for RWA system components . . . . . . . . . . . . . . . . . . . 6
Drives / RWA Opening Systems (24 V DC)
Chain drives ELTRAL K
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chain drive ELTRAL K20 / K25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 – 15
Chain drive ELTRAL K30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 – 19
Chain drive ELTRAL KS 30/40. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 – 24
Chain drive ELTRAL K60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 – 31
Spindle drives ELTRAL S / Rack and pinion drive ELTRAL Z
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Spindle drive ELTRAL S80 / S160. . . . . . . . . . . . . . . . . . . . . . . . . 33 – 36
Rack and pinion drive ELTRAL Z60. . . . . . . . . . . . . . . . . . . . . . . . 37 – 38
Locking actuators ELTRAL OA / VA
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Square spindle actuator ELTRAL OA . . . . . . . . . . . . . . . . . . . . . . . 40 / 44
Locking actuator ELTRAL VA25. . . . . . . . . . . . . . . . . . . . . . . . . . . 41 / 44
Locking actuator ELTRAL VA35. . . . . . . . . . . . . . . . . . . . . . . . . . . 42 / 44
Locking actuator ELTRAL VA-1 / VA-2. . . . . . . . . . . . . . . . . . . . . . 43 – 46
RWA opening systems
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Opening system RWA 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 – 51
Opening system RWA 1050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 – 56
Fanlight opener VENTUS F 300. . . . . . . . . . . . . . . . . . . . . . . . . . . 57 – 60
Door opening actuator
Door opening actuator TA 60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 – 63
Central control units (24 V DC)
Central control units RZ
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Compact central units RZ 2 and RZ 5. . . . . . . . . . . . . . . . . . . . . . 67 – 69
Modular central units RZ 10/2, RZ 24/4 and RZ 24/8 . . . . . . . . . . 70 – 74
Accessories for RWA installations
Manual alarm buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Automatic alarm devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Wind/rain detector, wind/rain evaluator . . . . . . . . . . . . . . . . . . . . . . . . 78
Ventilation switches, indicating labels . . . . . . . . . . . . . . . . . . . . . . . . . 79
Timer switch, voltage regulator, test kit, backup batteries . . . . . . . . . . 80
Ventilation Systems (230 V AC)
Chain drives ELTRAL K
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Chain drive ELTRAL K25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 / 84 / 91
Chain drive ELTRAL KS 30/40. . . . . . . . . . . . . . . . . . . . . . . . . 85 / 86 / 91
Chain drive ELTRAL K30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 / 88 / 92
Chain drive ELTRAL K60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 / 90 / 92
Spindle drive ELTRAL S / Rack and pinion drive ELTRAL Z
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Spindle drive ELTRAL S80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 – 96
Rack and pinion drive ELTRAL Z60. . . . . . . . . . . . . . . . . . . . . . . . 97 – 98
Fanlight opening systems
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Fanlight openers VENTUS F 200 / VENTUS F 300 . . . . . . . . . . . 100 – 105
Central control units LZ (Ventilation)
Central control units LZ 1 and LZ 6 . . . . . . . . . . . . . . . . . . . . . 106 – 107
Accessories
Rocker switches, biased rocker switches,
hand-held radio transmitter, power supply units. . . . . . . . . . . . . . . . . 107
Important advice
Planning and application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Service and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Product overview of G.U-BKS
Window technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 – 114
Door technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 – 120
Automatic entrance systems . . . . . . . . . . . . . . . . . . . . . . . . . . 121 – 122
Management systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 – 123
Software and Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 – 126
Contents
4 Edition 12.2009
Basement
Ground floor
First floor
Supply
air
Wind/rain detector
RAUCHABZUG
AUF ZU
RWA pushbutton + ventilation switch
RAUCHABZUG
AUF ZU
RWA control centre
RAUCHABZUG
Smoke/Maximum heat
detector
Smoke/Maximum heat
detector
Smoke/Maximum heat
detector
Exhaust
air
RWA pushbutton + ventilation switch
RWA systems
Smoke extraction and ventilation functions for staircases in one system
An appropriately designed and reliably func-tioning RWA installation
√ saves human lives√ ensures minimum smoke development in escape and rescue routes thus keeping them accessible
√ provides an unobstructed view and facili- tated fi re fi ghting
√ restricts the spread of fi re
Wherever maximum reliability is required of a smoke extracting installation in the event of a fi re and fumes need to be removed quickly, smoke and heat exhaust ventilation systems (RWA) can be used to open smoke outlets automatically and in a safe manner. This pro-tects occupants against smoke poisoning and property against damage. Within the context of everyday ventilation, RWA systems can be used to supply the desired fresh air.
√ protects building, furniture and stored goods against consequential damages
√ reduces fumes and possible subsequent chemical reactions
1
1
2
3
3
3
3
3
RWA system components
1 Drives / Opening systems
Used on roof-lights or façade openings, they ensure automated ventilation and reliable smoke extraction in the event of a fi re, and also provide natural room ventilation and thermal comfort.
2 Control centres
RWA control centres are responsible forsupplying, monitoring and controlling all the connected components as well as for ventilation control. The units fea-ture built-in batteries so that the sys-tems can still respond to a fi re in the event of a power failure for a period of 72 hours.
3 Accessories
Smoke and maximum heat detectors causing automatic alarm release in the event of a fi re, and RWA buttons for ma-nual operation. Ventilation switches are used to control ventilation and deaera-tion functions.
2
1
4
3
5Edition 12.2009
Smoke exhaust to EN 12101-2 (SHEV)
The Gretsch-Unitas system solution
For smoke extraction in the vertical dimen-sion (façade), the standard EN 12101 – part 2introduced, in September 2006, demands the installation of SHEV systems approved as a whole. It is therefore no longer possible to install an unapproved combination of single components, only SHEV installations are allowed which have been approved as a com- plete system.
Components of a SHEV system
1 Aluminium or timber window profi les
2 Glazing and gaskets
3 Window fi ttings (stays, hinges, etc.)
4 Drive system with associated fastening material
Especially in the fi eld of timber windows, the Gretsch-Unitas Group provides comprehen-sive SHEV system solutions for inward ope-ning window assemblies.
The SHEV system solution offered by the Gretsch-Unitas Group of Companies is based on the standardised Euro groove for alumi-nium profi le systems used by profi le manu-facturers such as, e.g., Alcoa, Alumil, Heroal, Reynaers, Raico and others.
SHEV system solutions approved in accor-dance with EN 12101 – part 2 guarantee a high degree of operational safety in the event of a fi re. Moreover, due to the system provider’s being obliged to clearly specify the components, product selection is made easy.
A G.U SHEV system consists of approved and certifi ed G.U fi ttings (stays, hinges, locking mechanisms) exclusively. All customary ope-ning methods for inward and outward ope-ning windows are possible.
Natural smoke and heat extraction ventilation system (SHEV) in accordance with EN 12101-2
Vorsprung mit System
Securing technology for you
6 Edition 12.2009
RWA systems
RWA system layout /Selection criteria for system components
RWA Ventilation
External fi re alarm system
RWA pushbutton HSE
Switching contacts for alarm and failure reports
Smoke detector / Maximum heat detector
Facility management
Wind/rain sensor
Ventilation switch
Timer switch /Temperature sensor
Opening systems / Drives
Control centre
System layout
Drives
√ How high is the window to be fi tted with a drive or opening system?
√ Which snow zone is the building located in?√ How large is the fl oor area of the room or staircase to be equipped with a RWA system? Which geometrical or aerodynamically effi - cient opening area is demanded by the building authority? Are there any obstacles such as, e.g., lintels or special profi le thick- nesses to be taken into account?
√ Which type, size and number of window(s) and which opening direction are to be considered when planning the RWA installation?
√ How heavy are the window sashes? Are the drives and fastening elements suited to resist the forces arising on the windows and to achieve the opening widths required?
√ Which mounting method is preferred? (face-fi xed or concealed assembly?)
√ Are the supply and exhaust air openings freely accessible, thus requiring extra safety (burglary preventing) installations?
√ What other infl uences are to be expected?
Control centres
√ Have all openings demanded by the type of building and required according to legal regulations been determined?
√ Have the current consumption values (Ampere) of all drives to be controlled by the RWA centre been summed up?
√ Is it necessary to confi gure ventilation groups? If yes, how many?√ Is automatic triggering through temperature rise or smoke forma- tion useful in addition to the manual release option?
√ Are wind and/or rain sensors to be considered?√ Are alarm or failure reports to be transmitted elsewhere?
Selection criteriaThe questions listed below are intended to make it easy for potential buyers to select the appropriate RWA system components.
77Edition 12.2009
24 V DC Drives
Chain drives ELTRAL K
Spindle drives ELTRAL S
Rack and pinion drive ELTRAL Z
Locking actuators ELTRAL OA / VA
RWA opening systems
Door opening actuatorTA 60
8 Edition 12.2009
Chain drives ELTRAL K
Chain drives ELTRAL K20 K25 K30 KS 30/40 [1] K60
Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %
Pushing force (N) 200 250 [2] 300 [2] 300 [2] 600 [2]
Pulling force (N) 200 250 300 300 600
Current consumption (A) 0,5 0,8 0,9 0,9 0,8
Breaking current (A) 0,7 1,0 1,2 1,2 1,2
Opening width (stroke)
(mm) 200/300/400 200/300/400500/600
200/300/400/500 110/200/300/400 250/400/500/600800/1000
IP protection class 32 32 32 30 32
Ambient temperature -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +65 °C -5 °C up to +65 °C -5 °C up to +75 °C
Suitable for roof-lights no no yes no yes
Synchronising control no no yes no yes [3]
Concealed installation acc. to profi le acc. to profi le no no no
DimensionsL x H x D
(mm) 335 x 26 x 41(stroke 200 mm)
335 x 26 x 41(stroke 200 mm)
456 x 43 x 60(all strokes)
386,5 x 38,1 x 58,5(all strokes)
461 x 40 x 56(stroke 250 mm)
Connecting cable Silicone, 3 m, 2-core
Silicone, 3 m,3-core
Silicone; 2 m, 2-core (Solo)
2,5 m, 5-core (Synchro)
2 m, 2-core (Solo)2,5 m, 4-core
(Synchro)
Silicone, 5 m,5-core
Detail informationsee page
9 – 15 9 – 15 16 – 19 20 – 24 25 – 31
With their compact design and pleasant ap-pearance, chain drives are an ideal solution for the fast, electromotor driven opening of exhaust air apertures and for room ventila-tion.
A large variety of mounting brackets allows for assembly in almost every building situ-ation:
– face-fi xed or concealed assembly
– assembly on inward or outward opening top or bottom hung windows, parallel off- set windows, projecting top hung windows, horizontal or vertical pivoting windows, side hung windows, and roof- lights
The intelligent drive technology enables the synchronous control of several chain drives, also in combination with locking actuators.
[1] Due to its plastic case, the ELTRAL KS 30/40 type is not approved for RWA use within the EU.[2] Depending on stroke[3] Up to 500 mm stroke
Product overview
9Edition 12.2009
145
41
26
12
13
13
Total length L
7
12 6
12
Stroke
Product features SHEV-tested and certified [1]
Compact size
Stainless steel chain
Integral microprocessor controller
Synchronised tandem operation [1]
Electronic limit stop switch
Automatic overload cut-off
Suitable for small sash heights
Total length 200 mm stroke L = 335 mm
300 mm stroke L = 380 mm
400 mm stroke L = 430 mm
500 mm stroke L = 545 mm
600 mm stroke L = 545 mm
Technical data
Chain drive ELTRAL K20 / K25
Product features, Dimensioned drawing, Technical data
Type of drive ELTRAL K20 ELTRAL K25
Nominal voltage 24 V DC
Push/pull force 200 N 250 N [2]
Current consumption 0,5 A 0,8 A
Breaking current 0,7 A 1,0 A
Stroke speed 8 mm/s 8 mm/s (12 mm/s [3])
Duty ratio 30 %
Locking pressure 3000 N
IP protection class 32
Connecting cable Silicone, 3 m, 2-core Silicone, 3 m, 3-core
Case Aluminium EV1 anodised
Dimensioned drawing
Dimensions L x 26 x 41 mm L x H x D
[1] Only ELTRAL K25 [2] Depending on stroke [3] From stroke 500 mm
10 Edition 12.2009
Chain drive ELTRAL K20 / K25
Application range [1]
350
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
500
250
750
1000
1250
1500
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
K20
ELTRAL K20
350
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
500
425
750
1000
1250
1500
1750
2000
2250
2500
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
K25 VA [2] K25 Synchro VA [2]
K25K25 Synchro
ELTRAL K25
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.[2] VA = Locking actuator (see page 39 et seq.)
Application diagrams
Thrust diagrams
ELTRAL K20 ELTRAL K25
100 200 300 400
100
200
300
0
0
Th
rust
(N
)
Stroke (mm)
100 200 300 400
100
200
300
500 600
0
0
Th
rust
(N
)
Stroke (mm)
11Edition 12.2009
Chain drive ELTRAL K20 / K25
Order information – Drives
Description Stroke Order number
ELTRAL K20
200 mm
300 mm
400 mm
K-17645-20-0-1
K-17645-30-0-1
K-17645-40-0-1
ELTRAL K25 200 mm
300 mm
400 mm
500 mm
600 mm
K-17646-20-0-1
K-17646-30-0-1
K-17646-40-0-1
K-17646-50-0-1
K-17646-60-0-1
ELTRAL K25
with locking actuator VA25
consisting of 1 chain drive and 1 locking actuator200 mm
300 mm
500 mm
K-17722-20-0-1
K-17722-30-0-1
K-17722-50-0-1
ELTRAL K25 Synchro
consisting of 2 chain drives
200 mm
300 mm
400 mm
500 mm
600 mm
K-17581-20-0-1
K-17581-30-0-1
K-17581-40-0-1
K-17581-50-0-1
K-17581-60-0-1
ELTRAL K25 Synchro
with locking actuator VA25
consisting of 2 chain drives and 1 locking actuator
200 mm
300 mm
500 mm
K-17723-20-0-1
K-17723-30-0-1
K-17723-50-0-1
Note: Mounting sets must be ordered separately.
12 Edition 12.2009
Description Joinery Order number
Mounting set for fi xing on sash
for bottom hung sash opening inward / top hung sash opening outward
Aluminium [2]
Timber / PVC [3]
K-17595-00-0-8
K-17637-00-0-8
min
. spa
ce r
equi
rem
ent
22
Minimum sash height depending on stroke
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 325* 450* 550* 700* 800*
Mounting set for fi xing on frame
for top or bottom hung sash opening inward
Aluminium [2]
Timber / PVC [3]
K-17594-00-0-8
K-17636-00-0-8
min
. spa
ce r
equi
rem
ent
33
Minimum sash height depending on stroke
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 250*/425 350*/500 550*/600 750* 950*
Chain drive ELTRAL K20 / K25
Order information – Mounting sets for face-fixed assembly
* Pivotable mounted drive, sash weight ≤ 30 kg/m2 [1] Only for bottom hung inward opening sashes (tensile load) [2] With fi xing screws [3] Without fi xing screws
13Edition 12.2009
Chain drive ELTRAL K20 / K25
Order information – Mounting sets for face-fixed assembly
Description Joinery Order number
Mounting set for direct fi xing on frame
for top or bottom hung sash opening inward
Aluminium [2]
Timber / PVC [3]
K-17593-00-0-8
K-17635-00-0-8
min
. spa
ce r
equi
rem
ent
30
Minimum sash height depending on stroke
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 425 500 600 750 950
Mounting set for fi xing on frame, with base plate
for top hung sash opening outward
Aluminium [1] K-17706-00-0-8
min
. spa
ce r
equi
rem
ent
19
.5
Stroke (mm) 200 300 400
Minimum sash height (mm) 325 450 550
[1] Only for bottom hung inward opening sashes (tensile load) [2] With fi xing screws [3] Without fi xing screws
14 Edition 12.2009
Chain drive ELTRAL K20 / K25
Order information – Mounting sets for various profile systems – concealed assembly
Description Joinery Order number
Mounting set S
Aluminium K-17874-00-0-0
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 500 650 800 1000 1200
Base plate for mounting set S K-17874-00-0-0
Aluminium K-17875-00-0-0
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 500 650 800 1000 1200
Note: Other profi le systems on request. [1] Only for bottom hung inward opening sashes (tensile load)
15Edition 12.2009
Chain drive ELTRAL K20 / K25
Order information – Mounting sets for various profile systems – concealed assembly
Description Joinery Order number
Mounting set W / universal aluminium
Aluminium K-17880-00-0-111
.9
15
.9
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 500 650 800 1000 1200
Mounting set / universal timber
Timber K-17909-00-0-1
Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]
Minimum sash height (mm) 500 650 800 1000 1200
Note: Other profi le systems on request. [1] Only for bottom hung inward opening sashes (tensile load)
456
43
60
228
28
.5
30
16 Edition 12.2009
Chain drive ELTRAL K30
Product features, Dimensioned drawing, Technical data
Product features SHEV-tested and certified
Suitable for customary profiles with Euro groove
Compact size
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Independent of sash overlap dimension
Automatic overload cut-off
Suitable for small sash heights
Variable stroke adjustment
Automatic gasket relief
Technical data
Type of drive ELTRAL K30
Nominal voltage 24 V DC
Push/pull force 300 N
Current consumption 0,9 A
Breaking current 1,2 A
Opening width (adjustable) 200 mm / 300 mm / 400 mm / 500 mm
Stroke speed 12,5 mm/s
Duty ratio 30 %
Locking pressure 2000 N
IP protection class 32
Connecting cable Silicone; 2 m, 2-core (Solo) / 2,5 m, 5-core (Synchro)
Case Zinc die cast
Dimensioned drawing Dimensions 456 x 43 x 60 mm L x H x D
17Edition 12.2009
Chain drive ELTRAL K30
Application range [1]5
00
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
19
00
20
00
21
00
22
00
23
00
24
00
25
00
26
00
500
250
750
1000
1250
1500
K30 K30 Synchro
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
Application diagram
Minimum sash height depending on stroke
Stroke (mm) 200 300 400 500
Minimum sash height (mm) 200 300 400 500
Assembly on frame, bottom hung sash opening inward
Stroke (mm) 200 300 400 500
Minimum sash height (mm) 200 400 650 900
Assembly on sash, bottom hung sash opening inward
Stroke (mm) 200 300 400 500
Minimum sash height (mm) 250 350 450 600
Assembly on frame, top hung sash opening outward
Thrust diagram
100 200 300 400 500
100
200
300
400
0
0
Th
rust
(N
)
Stroke (mm)
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.
18 Edition 12.2009
Chain drive ELTRAL K30
Order information – Drives
Description Stroke Order number
ELTRAL K30 200 mm
300 mm
400 mm
500 mm
K-17832-00-0-*
ELTRAL K30 Synchro
consisting of 2 chain drives 200 mm
300 mm
400 mm
500 mm
K-17833-00-0-*
Note: Mounting sets must be ordered separately. * = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)
19Edition 12.2009
Description Joinery Order number
Mounting set for fi xing on frame, for bottom hung sash opening inward
without fi xing screws
Aluminium /
Timber / PVCK-17837-00-0-*
min
. spa
ce r
equi
rem
ent
50
Mounting set for fi xing on frame, for projecting top hung window opening outward
without fi xing screws
Aluminium /
Timber / PVCK-17840-00-0-*
Mounting set for fi xing on sash,
for bottom hung sash opening inward / top hung sash opening outward [1]
without fi xing screws
Aluminium /
Timber / PVCK-17841-00-0-*
min
. spa
ce r
equi
rem
ent
37
Mounting set for fi xing on sash,
for bottom hung sash opening inward / top hung sash opening outward [2]
without fi xing screws
Aluminium /
Timber / PVCK-17843-00-0-*
min
. spa
ce r
equi
rem
ent
28
Chain drive ELTRAL K30
Order information – Mounting sets
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016) [1] = Max. overlap 4 mm [2] = Min. overlap 4 mm
38
.1
386.5
51
min
. 37
28
.5
58
.5
ø46
8.4
ø10
20 Edition 12.2009
Chain drive ELTRAL KS 30/40
Product features, Dimensioned drawing, Technical data
Product features Compact size
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Independent of sash overlap dimension
Automatic overload cut-off
Suitable for small sash heights
Variable stroke adjustment
Automatic gasket relief
Technical data
Type of drive ELTRAL KS 30/40
Nominal voltage 24 V DC
Push/pull force 300 N
Current consumption 0,9 A
Breaking current 1,2 A
Opening width (adjustable) 110 mm / 200 mm / 300 mm / 400 mm
Stroke speed 10 mm/s
Duty ratio 30 %
Locking pressure 1000 N
IP protection class 30
Connecting cable 2 m, 2-core (Solo) / 2,5 m, 4-core (Synchro)
Case PVC
Dimensioned drawing Dimensions 386,5 x 38,1 x 58,5 mm L x H x D
Note:
Due to its plastic case, this drive type
is not approved for RWA use within
the EU.
21Edition 12.2009
Chain drive ELTRAL KS 30/40
Application range [1]
50
0
40
0
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
20
00
19
00
21
00
22
00
23
00
24
00
25
00
26
00
500
250
750
1000
1250
1500
KS 30/40 KS 30/40 Synchro
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
Application diagram
Minimum sash height depending on stroke
Stroke (mm) 110 200 300 400
Minimum sash height (mm) 250 600 1100 1500
Assembly on frame, bottom hung sash opening inward
Stroke (mm) 110 200 300 400
Minimum sash height (mm) 200 400 650 900
Assembly on sash, bottom hung sash opening inward
Stroke (mm) 110 200 300 400
Minimum sash height (mm) 150 250 350 450
Assembly on frame, top hung sash opening outward
Thrust diagram
100 200 300 400
100
200
300
400
0
0
Th
rust
(N
)
Stroke (mm)
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.
22 Edition 12.2009
Chain drive ELTRAL KS 30/40
Order information – Drives
Description Stroke Order number
ELTRAL KS 30/40 110 mm
200 mm
300 mm
400 mm
K-17434-00-0-*
ELTRAL KS 30/40 Synchro
consisting of 2 chain drives 110 mm
200 mm
300 mm
400 mm
K-17436-02-0-*
Note: Mounting sets must be ordered separately. * = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)
23Edition 12.2009
Chain drive ELTRAL KS 30/40
Order information – Mounting sets
Description Joinery Order number
Mounting set for fi xing on frame, for bottom hung sash opening inward
without fi xing screws
Aluminium /
Timber / PVC
delivered with
the drive
min
. spa
ce r
equi
rem
ent
45
Mounting set for fi xing on sash,
for bottom hung sash opening inward / top hung sash opening outward
without fi xing screws
Aluminium /
Timber / PVC
delivered with
the drive
min
. spa
ce r
equi
rem
ent
28
Chain holder
for bottom hung sash opening inward – fi xing on sash /
for top hung sash opening outward – fi xing on frame
without fi xing screws
Aluminium /
Timber / PVCK-17441-00-0-*
min
. spa
ce r
equi
rem
ent
22
Chain holder
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)
24 Edition 12.2009
Chain drive ELTRAL KS 30/40
Order information – Mounting sets
Description Joinery Order number
Pivot bearing for bottom hung sash opening inward – fi xing on frame
without fi xing screws
Aluminium /
Timber / PVCK-17440-00-0-*
17
.5
Pivot bearing
Chain holder for projecting top hung window opening outward – fi xing on frame
without fi xing screws
Aluminium /
Timber / PVC9-44272-00-0-*
Chainholder
Metal mounting set
for bottom hung sash opening inward – fi xing on sash
for top hung sash opening outward – fi xing on frame
without fi xing screws
Aluminium /
Timber / PVCK-17720-00-0-*
min
. spa
ce r
equi
rem
ent
22
Metalmounting set
Pivot bearing for roof-lights – fi xing on frame
without fi xing screws
Aluminium /
Timber / PVCK-17735-00-0-*
14
Pivot bearing
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)
25Edition 12.2009
40
16
230
1819
Total length L56
Product features SHEV-tested and certified
Compact size
Stainless steel chain
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Automatic overload cut-off
Pivotable mountings allow for small sash heights from 350 mm
Emergency release
Total length 250 mm stroke L = 461 mm
400 mm stroke L = 537 mm
500 mm stroke L = 639 mm
600 mm stroke L = 639 mm
800 mm stroke L = 740 mm
1000 mm stroke L = 842 mm
Chain drive ELTRAL K60
Product features, Dimensioned drawing, Technical data
Dimensioned drawing
Dimensions L x 40 x 56 mm L x H x D
Technical data
Type of drive ELTRAL K60 ELTRAL K60 – 300 N
Nominal voltage 24 V DC 24 V DC
Push/pull force 600 N 300 N
Current consumption 0,8 A 0,8 A
Breaking current 1,2 A 1,0 A
Stroke speed 9 mm/s (7,5 mm/s [1]) 13,1 mm/s
Duty ratio 30 %
Locking pressure 3000 N
IP protection class 32
Connecting cable Silicone, 5 m, 5-core
Case Aluminium EV1 anodised
[1] With 250 and 400 mm stroke
26 Edition 12.2009
Chain drive ELTRAL K60
Application range [1]
50
0
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
19
00
20
00
21
00
22
00
23
00
24
00
25
00
26
00
500
425
750
1000
1250
1500
1750
2000
2250
2500
K60 VA [2] K60 Synchro VA [2]
K60K60 Synchro
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
Application diagram
Thrust diagram
100 200 300 400 500 600 700 800 900 1000
100
200
300
400
500
600
0
0
Th
rust
(N
)
Stroke (mm)
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.[2] VA = Locking actuator (see page 39 et seq.)
27Edition 12.2009
Chain drive ELTRAL K60
Order information – Drives
Description Stroke Order number
ELTRAL K60 250 mm
400 mm
500 mm
600 mm
800 mm
1000 mm
K-17648-25-0-1
K-17648-40-0-1
K-17648-50-0-1
K-17648-60-0-1
K-17648-80-0-1
K-17648-01-0-1
ELTRAL K60 Synchro
consisting of 2 chain drives
250 mm
400 mm
500 mm
600 mm
K-17583-25-0-1
K-17583-40-0-1
K-17583-50-0-1
K-17583-60-0-1
ELTRAL K60 – 300 N500 mm
600 mm
K-17882-50-0-1
K-17882-60-0-1
ELTRAL K60 – 300 N Synchro
consisting of 2 chain drives
500 mm
600 mm
K-17883-50-0-1
K-17883-60-0-1
Note: Mounting sets must be ordered separately.
28 Edition 12.2009
Chain drive ELTRAL K60
Order information – Mounting sets
Description Joinery Order number
Mounting set for fi xing on sash, bottom hung sash opening inward /
Mounting set for fi xing on frame, top hung sash opening outward
Aluminium, short
Timber /
PVC, short
Aluminium, long
Timber /
PVC, long
K-17596-00-0-8
K-17638-00-0-8
K-17598-00-0-8
K-17640-00-0-8min
. spa
ce r
equi
rem
ent
38
min
. spa
ce r
equi
rem
ent
63
Minimum sash height depending on stroke
Stroke (mm) 250 400 500 600 800 [1] 1000 [1]
Min. sash height (mm) / short 450 750 1000 1250 1600 2100
Min. sash height (mm) / long 250 400 550 700 900 1200
Mounting set for fi xing on frame,
for projecting top hung sash opening outward
Aluminium K-17597-00-0-8
min
. spa
ce r
equi
rem
ent
37
Minimum sash height depending on stroke
Stroke (mm) 250 400 500 600
Minimum sash height (mm) 350 900 1100 1400
Mounting set for fi xing on frame,
bottom hung sash opening inward
Aluminium
Timber / PVC
K-17661-00-0-8
K-17662-00-0-8
min
. spa
ce r
equi
rem
ent
48
Minimum sash height depending on stroke
Stroke (mm) 250 400 500 600 800 1000
Minimum sash height (mm) 350 700 1000 1250 1800 2300
29Edition 12.2009
Chain drive ELTRAL K60
Order information – Mounting sets
Description Joinery Order number
Mounting set for fi xing on sash, bottom hung sash opening inward /
Mounting set for fi xing on frame, top hung sash opening outward
Aluminium
Timber / PVC
K-17659-00-0-1
K-17660-00-0-1
min
. spa
ce r
equi
rem
ent
34
Minimum sash height depending on stroke
Stroke (mm) 250 400 500 600 800 [1] 1000 [1]
Minimum sash height (mm) 350 600 750 900 1100 1400
Mounting set S for fi xing on frame, for roof-lights
Aluminium K-17606-00-0-1
Minimum sash height depending on stroke
Stroke (mm) 250 400 500
Minimum sash height (mm) 350 900 1100
[1] Only for bottom hung inward opening sashes (tensile load)
30 Edition 12.2009
Chain drive ELTRAL K60
Order information – Mounting sets
Description Joinery Order number
Mounting set RS for fi xing on frame, for roof-lights
Aluminium K-17608-00-0-1
Minimum sash height depending on stroke
Stroke (mm) 250 400 500
Minimum sash height (mm) 350 900 1100
Mounting set W for fi xing on frame, for roof-lights
Aluminium K-17609-00-0-8
Minimum sash height depending on stroke
Stroke (mm) 250 400 500
Minimum sash height (mm) 350 900 1100
31Edition 12.2009
Chain drive ELTRAL K60
Order information – Accessories
Description Length Order number
Set of base plates [1]
for mounting sets for sash overlap < 10 mm
K-17653-00-0-11
85
70
18
3
70
35
47
.5
5
2 x 2 x 1 x
Cover profi le K60
L = 1450 mm
L = 3000 mm
9-42211-00-0-1
9-42212-00-0-1
Mounting set for cover profi le K60
consisting of: end caps (left / right), 2 spacers, 4 adhesive points, 1 sealing plug
K-17719-00-0-1
[1] For fl ush frame and sash profi les it is necessary to use 2 base plates.
32 Edition 12.2009
Spindle drives ELTRAL S / Rack and pinion drive ELTRAL Z
Regardless of whether in shopping centres, theatre foyers, airport terminals, or con-servatories – modern spindle or rack and pinion drives on large and heavy roof-lights or façade openings provide fast natural smoke extraction and comfortable auto-matic everyday ventilation.
Spindle and rack and pinion drives are the ideal solution when it comes to opening and closing heavy roof-lights.
Spindle drives and rack and pinion drive ELTRAL
S80 / S80 Synchro S160 Z60
Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %
Pushing force (N) 800 1600 600
Pulling force (N) 800 1600 600
Current consumption (A) 1,0 0,7 1,6
Breaking current (A) 1,4 1,2 2,0
Opening width (stroke) (mm) 300/500/750/1000 300/500/750/1000 180/230/350/550/750/1000
IP protection class 65 65 55
Ambient temperature -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +65 °C
Synchronising control electronic no mechanical
Dimensions L x øDimensions W x H x L
(mm)(mm)
(302 mm + stroke) x 36 (302 mm + stroke) x 3643 x 142 x (135 mm + stroke)
Connecting cable Silicone, 2,5 m, 4-core Silicone, 2,5 m, 4-core 2 m, 2-core
Detail informationsee page
33 – 36 33 – 36 37 – 38
Product overview
33Edition 12.2009
Extended drive
Returned drive
Ø3
6
19L = 302 + stroke
Stroke
Ø1
8
8
Product features Compact size
Stainless steel thrust tube
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Automatic overload cut-off
Fire tested up to 300 °C
Total length 300 mm stroke L = 602 mm
500 mm stroke L = 802 mm
750 mm stroke L = 1052 mm
1000 mm stroke L = 1302 mm
Technical data
Spindle drive ELTRAL S80 / S160
Product features, Dimensioned drawing, Technical data
Type of drive ELTRAL S80 ELTRAL S160
Nominal voltage 24 V DC
Push/pull force 800 N 1600 N
Current consumption 1,0 A 0,7 A
Breaking current 1,4 A 1,2 A
Stroke speed 10,4 mm/s 7,1 mm/s
Duty ratio 30 %
Locking pressure 12000 N
IP protection class 65
Connecting cable Silicone, 2,5 m, 4-core
Case Aluminium EV1 anodised
Dimensioned drawing
Dimensions (302 + stroke) x 36 mm L x ø
34 Edition 12.2009
Spindle drive ELTRAL S80 / S160
Order information – Drives
Description Stroke Order number
ELTRAL S80 300 mm
500 mm
750 mm
1000 mm
9-42898-30-0-1
9-42898-50-0-1
9-42898-75-0-1
9-42898-01-0-1
ELTRAL S80 Synchro
consisting of 2 spindle drives with synchronisation control300 mm
500 mm
750 mm
1000 mm
K-17584-30-0-1
K-17584-50-0-1
K-17584-75-0-1
K-17584-01-0-1
ELTRAL S160 300 mm
500 mm
750 mm
1000 mm
9-39075-30-0-1
9-39075-50-0-1
9-39075-75-0-1
9-39075-01-0-1
Note: Mounting sets must be ordered separately.
35Edition 12.2009
Spindle drive ELTRAL S80 / S160
Order information – Mounting sets
Description Drive Order number
Mounting set S for roof-lights
without fi xing screws
ELTRAL S80
ELTRAL S160
K-17762-00-0-1
K-17767-00-0-1
ELTRAL S80 ELTRAL S160
Mounting set RS for roof-lights
without fi xing screws
ELTRAL S80
ELTRAL S160
K-17764-00-0-1
K-17769-00-0-1
ELTRAL S80 ELTRAL S160
36 Edition 12.2009
Description Drive Order number
Mounting set W for roof-lights
without fi xing screws
ELTRAL S80 /
ELTRAL S160K-17765-00-0-1
provided by customer
Mounting set for roof-lights / universal
without fi xing screws
ELTRAL S80 /
ELTRAL S160K-17766-00-0-1
30
40
40
46
Spindle drive ELTRAL S80 / S160
Order information – Mounting sets
37Edition 12.2009
25.517
33.6
32
Ø12
48
135 + stroke
43
54
260
45
97.5
Rack and pinion drive ELTRAL Z60
Product features, Dimensioned drawing, Technical data
Product features Compact size
Galvanised thrust tube
Tandem operation with connecting rod
Electronic limit stop switch
Automatic overload cut-off
Multiple operation with up to 4 drives
Note:
With heavy and large sashes it is possible to operate several drives in a row. A rack and pinion follower can be used as additional opening/locking element (both in single-drive and multiple-drive operating mode). Synchro-nisation between the drives or between drive and follower is effected by means of a mecha-nical connecting rod.
Total length 180 mm stroke L = 315 mm
230 mm stroke L = 365 mm
350 mm stroke L = 485 mm
550 mm stroke L = 685 mm
750 mm stroke L = 785 mm
1000 mm stroke L = 1135 mm
Technical data
Type of drive ELTRAL Z60
Nominal voltage 24 V DC
Push/pull force 600 N
Current consumption 1,6 A
Breaking current 2,0 A
Stroke speed 9,5 mm/s
Duty ratio 30 %
Locking pressure 3000 N
IP protection class 55
Connecting cable 2 m, 2-core
Dimensioned drawing
Dimensions 43 x 142 x (135 + stroke) mm W x H x L
38 Edition 12.2009
Rack and pinion drive ELTRAL Z60
Order information – Drives
Description Stroke / Length Order number
ELTRAL Z60
180 mm
230 mm
350 mm
550 mm
750 mm
1000 mm
K-17836-18-0-1
K-17836-23-0-1
K-17836-35-0-1
K-17836-55-0-1
K-17836-75-0-1
K-17836-01-0-1
Rack and pinion follower ELTRAL Z60 180 mm
230 mm
350 mm
550 mm
750 mm
1000 mm
K-17844-18-0-1
K-17844-23-0-1
K-17844-35-0-1
K-17844-55-0-1
K-17844-75-0-1
K-17844-01-0-1
Connecting rodL = 1000 mm
L = 1500 mm
L = 2000 mm
L = 2500 mm
9-45469-10-0-1
9-45469-15-0-1
9-45469-20-0-1
9-45469-25-0-1
Ø1
3
Ø1
1
24°
L
39Edition 12.2009
Locking actuators ELTRAL OA / VA
Suited for use on top or bottom hung windows, projecting top hung windows, parallel offset windows and side hung windows, the locking actuators provide for the motor-driven locking and unlockingof a face-fi xed lock or of the central locking mechanism recessed in the window profi le.
The locking actuators are used in combina-tion with the chain drive types K25 or K60.
Locking actuators ELTRAL OA VA25 VA35VA-1 R/4VA-1 L/4
VA-2/12VA-2/20
Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %
Thrust (N) – 600 600 600 600
Torque (Nm) 10 – – – –
Current consumption (A) 1,1 0,7 0,7 0,8 0,8
Opening stroke(adjustable)
(mm)(°) 90 / 180
17 / 36 18– –
IP protection class 32 32 32 32 32
Ambient temperature -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +75 °C
Synchronising control no no optional optional optional
Concealed installation no yes no no no
Dimensions L x W x H
(mm)156 x 40 x 83,5 473 x 25,2 x 25,2 420 x 35 x 35 420 x 35 x 35
1200 x 35 x 352000 x 35 x 35
Connecting cable Silicone, 2,5 m, 4-core
Silicone, 2,5 m, 2-core
Silicone, 2,5 m, 4-core
Silicone, 2,5 m, 4-core
Silicone, 2,5 m, 4-core
Detail informationsee page
40 / 44 41 / 44 42 / 44 43 – 46 43 – 46
Product overview
93
.58
3.5
156
7 (square)
46
40
21.521.5
9237.8
40 Edition 12.2009
Square spindle actuator ELTRAL OA
Product features, Dimensioned drawing, Technical data
Product features SHEV-tested and certified
Compact size
Integral microprocessor controller
Electronic limit stop switch and overload cut-off
Integral closing sequence controller
Opening angle adjustable to 90° / 180° via DIP switch [1]
Technical data
Type of drive ELTRAL OA
Nominal voltage 24 V DC
Torque 10 Nm
Current consumption 1,1 A
Opening/closing speed 20°/s
Duty ratio 30 %
Locking force 22 Nm
IP protection class 32
Connecting cable Silicone, 2,5 m, 4-core
Max. switching current 3 A
Dimensioned drawing
Dimensions 156 x 40 x 83,5 mm L x W x H
Note: Depending on the profi le, the spindle must be cut to length by the customer.
Note: Only for use with chain drives ELTRAL K25/K60 (24 V) ! [1] Factory setting is 90°
30
34
459473
204.5
5.518.5
25.2
41Edition 12.2009
Locking actuator ELTRAL VA25
Product features, Dimensioned drawing, Technical data
Product features SHEV-tested and certified
Compact size
Integral microprocessor controller
Electronic limit stop switch and overload cut-off
Integral closing sequence controller
Stroke adjustable to 17 mm or 36 mm
Emergency release of the central locking mechanism
Switchable running direction
Technical data
Type of drive ELTRAL VA25
Nominal voltage 24 V DC
Nominal force 600 N
Current consumption 0,7 A
Speed 2,8 mm/s
Duty ratio 30 %
Locking pressure 1000 N
IP protection class 32
Connecting cable Silicone, 2,5 m, 2-core
Max. switching current 4,2 A
Dimensioned drawing
Dimensions 473 x 25,2 x 25,2 mm L x W x H
Note: Only for use with chain drives ELTRAL K25/K60 (24 V) !
42 Edition 12.2009
Locking actuator ELTRAL VA35
Product features, Dimensioned drawing, Technical data
Product features Compact size
Integral microprocessor controller
Electronic limit stop switch and overload cut-off
Integral closing sequence controller
Stroke: 18 mm
Fire tested up to 300 °C
Technical data
Type of drive ELTRAL VA35
Nominal voltage 24 V DC
Nominal force 600 N
Current consumption 0,7 A
Speed 4,2 mm/s
Duty ratio 30 %
Locking pressure 1000 N
IP protection class 32
Connecting cable Silicone, 2,5 m, 4-core
Case Aluminium EV1 anodised
Max. switching current 3 A
Dimensioned drawing
Dimensions 420 x 35 x 35 mm L x W x H
420
Stroke 18 ±1
11
25
364
16
9.5
9.5
35
35
28
26896
12
35
Position 1Position 2
Note: Only for use with chain drives ELTRAL K25/K60 (24 V) !
111420
35
35
364
16
9.5
31
1030
60
34
17
.5
46
43Edition 12.2009
Locking actuator ELTRAL VA-1 / VA-2
Product features, Dimensioned drawing, Technical data
Product features SHEV-tested and certified
Compact size
Integral microprocessor controller
Electronic limit stop switch and overload cut-off
Integral closing sequence controller
Available with 1 or 2 locking points
Technical data
Type of drive ELTRAL VA-1 / ELTRAL VA-2
Nominal voltage 24 V DC
Nominal force 600 N
Current consumption 0,8 A
Speed 4,2 mm/s
Duty ratio 30 %
Locking pressure 2000 N
IP protection class 32
Connecting cable Silicone, 2,5 m, 4-core
Case Aluminium EV1 anodised
DimensionsELTRAL VA-1 R/4 – VA-1 L/4
420 x 35 x 35 mm L x W x H
ELTRAL VA-2/12
1200 x 35 x 35 mm L x W x H
ELTRAL VA-2/20
2000 x 35 x 35 mm L x W x H
Dimensioned drawing
Drawing shows ELTRAL VA-1 R/4
Note: Only for use with chain drives ELTRAL K25/K60 (24 V) !
44 Edition 12.2009
Locking actuators ELTRAL OA / VA
Order information – Drives
Description Connection rh/lh /
Length
Order number
ELTRAL OA
9-44712-00-0-1
ELTRAL VA25
K-17724-00-0-8
==
ELTRAL VA35
K-17725-00-0-1
ELTRAL VA-1 R/4, VA-1 L/4
Drive with 1 locking point, face-fi xed
Connection rh
Connection lh
K-17591-42-R-1
K-17591-42-L-1
Drawing shows rh cable connection (lh cable connection = laterally reversed)
ELTRAL VA-2/12, VA-2/20
Drive with 2 locking points
L = 1200 mm
L = 2000 mm
K-17591-12-0-1
K-17591-20-0-1
45Edition 12.2009
Description Drive Order number
Base plate for mounting on top, bottom, and side hung sashes opening outward
ELTRAL VA-1 R/4
ELTRAL VA-1 L/49-40092-00-0-1
10115.5
10115.5
9.5
9.5
16
50
60
115364
415
5M
5 (
4x)
Ø5
.5 (
4x)
Base plate for mounting on top, bottom, and side hung sashes opening outward
ELTRAL VA-2/12 9-40093-00-0-1
10301
10301
9.5
9.5
16
50
60
5301146
1200
5M
5 (
4x)
Ø5
.5 (
4x)
Base plate for mounting on top, bottom, and side hung sashes opening outward
ELTRAL VA-2/20 9-42197-00-0-1
10301
10301
9.5
9.5
16
50
60
10001946
2000
5M
5 (
5x)
Ø5
.5 (
5x)
Spacer for angular locking bracket – for sash opening outward
from 7 mm overlap
9-42199-00-0-130
20
70
33
616
6.5 Overlap > 7 mm
Spacer
Locking actuator ELTRAL VA-1 / VA-2
Order information – Mounting accessories
46 Edition 12.2009
Locking actuator ELTRAL VA-1 / VA-2
Order information – Mounting accessories
Description Drive Order number
Spacer for ELTRAL VA-1 R/4, VA-1 L/4
for bottom hung sashes with overlap 12 – 25 mm [1]
415
36425.5
9.5
16
Ø5.5
35
10 Overlap
12 – 25 mm
Spacer
min
. 35
ELTRAL VA-1 R/4
ELTRAL VA-1 L/49-42208-00-0-0
Spacer for ELTRAL VA-2/12
for bottom hung sashes with overlap 12 – 25 mm [1]
ELTRAL VA-2/12 9-42209-00-0-0
1200
114627
9.5
16
Ø5.5
35
10
Spacer for ELTRAL VA-2/20
for bottom hung sashes with overlap 12 – 25 mm [1]
ELTRAL VA-2/20 9-42210-00-0-0
2000
194627
9.5
16
Ø5.5
35
10
700
Sash bracket, small
9-45547-00-0-146
Ø5.5
50
60
10
Ø8
11
.9
[1] Additional spacer required with overlaps exceeding 25 mm.
47Edition 12.2009
RWA opening systems
Opening system RWA 1000 Automatic opening and closing of top, bottom, and side hung windows opening inward.
Opening system RWA 1050 Automatic opening and closing of side hung windows opening inward.
System components:
• Drive• Mounting set • Electromechanical locking element(s)
Fanlight opener VENTUS F 300 [*]
Effi cient smoke extraction by means of the electro-motor-driven fanlight fi ttings VENTUS F 300 designed for rectangular, vertically installed bottom hung win-dows of timber, PVC or aluminium; electric drives: ELTRAL S 24 L or ELTRAL 300/24.
Opening systems RWA 1000 RWA 1050 VENTUS F 300with ELTRAL S 24 L
VENTUS F 300with ELTRAL 300/24
Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %
Thrust (N) 1000 600 1200 3000
Duty ratio (%) 30 30 20 20
Current consumption (A) 0,8 0,6 0,7 0,8
Opening width / Stroke (mm) 100 / 200 / 300 100 / 150 / 200 / 250 70 100
IP protection class 54 54 54 54
Synchronising control electronic electronic no no
Dimensions L x W x H (mm) 156 x 40 x 83,5 472 x 25,2 x 25,2 210 x 36 x 76 270 x 55 x 102
Connecting cable Silicone, 2,5 m, 2-core Silicone, 2,5 m, 2-core Silicone, 1,5 m, 4-core Silicone, 1,5 m, 4-core
Detail informationsee page
48 – 51 52 – 56 57 – 60 57 – 60
[*] For further information see our order catalogues “Builder’s Hardware for timber/PVC/aluminium windows and patio doors”
Product overview
48 Edition 12.2009
Product features Electromechanical sash locking (single or double)
Large opening widths with short strokes even for small-height sashes
Integral closing and opening sequence control
Ventilation control can be integrated as an option
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch and overload cut-off
Max. weight of glazing: 30 kg/m2
Min. space requirement for drive: min. 38 mm
Min. space requirement for mounting bracket: min. 40 mm
Fire tested up to 300 °C
Opening system RWA 1000
Product features, Technical data
Technical data
Opening system RWA 1000
Nominal voltage 24 V DC
Nominal force 1000 N
Current consumption 0,8 A
Breaking current 1,4 A
Speed 2,6 mm/s
Duty ratio 30 %
Locking pressure 12000 N
IP protection class 54
Connecting cable Silicone, 2,5 m, 2-core
Case Aluminium EV1 anodised
Max. switching current 3 A
49Edition 12.2009
38
150
S100 =
256+stroke
35
Dimensioned drawing
Opening system RWA 1000
Application range, Dimensioned drawing
Opening system Sash height (mm) [1] Opening width (mm) Opening angle (°)
RWA 1000 Stroke 100 mm
550 – 600
600 – 650
650 – 1400
300 – 280
330 – 300
360 – 220
32 – 27
32 – 27
32 – 10
RWA 1000 Stroke 200 mm
700 – 750
750 – 800
800 – 850
850 – 900
900 – 950
950 – 1000
1000 – 1100
1100 – 1200
1200 – 1300
1300 – 1400
1400 – 1500
1500 – 1600
720 – 650
770 – 690
805 – 730
810 – 740
830 – 760
850 – 780
895 – 750
860 – 750
890 – 780
880 – 785
890 – 800
890 – 800
62 – 51
62 – 51
60 – 50
57 – 48
56 – 47
53 – 46
53 – 40
46 – 37
44 – 35
40 – 33
37 – 31
34 – 29
RWA 1000 Stroke 300 mm
1000 – 1100
1100 – 1200
1200 – 1300
1300 – 1400
1400 – 1500
1500 – 1600
1600 – 1700
1700 – 1800
1800 – 1900
1900 – 2000
1050 – 935
1100 – 980
1200 – 1070
1195 – 1075
1190 – 1080
1210 – 1105
1250 – 1140
1285 – 1180
1320 – 1210
1370 – 1260
63 – 50
63 – 48
60 – 48
55 – 45
50 – 42
48 – 40
46 – 39
44 – 38
43 – 37
42 – 37
Maximum sash widths(referring to side of locking actuator)
Sash width [1]
Single locking
– Timber / Aluminium
– PVC – Solo
– PVC – S-Set
430 mm – 1200 mm
400 mm – 800 mm
800 mm – 1200 mm
Double locking (S-Set)
– Timber / Aluminium
– PVC
1200 mm – 2400 mm
1200 mm – 1800 mm
[1] Larger sash dimensions require the use of opening system RWA 1000 S-Set.
50 Edition 12.2009
Opening system RWA 1000
Order information – Opening systems
Description Stroke Order number
Opening system RWA 1000 Solo [1]
consisting of:
1 locking actuator, 1 spindle drive, mountings
100 mm
200 mm
300 mm
K-17585-10-0-1
K-17585-20-0-1
K-17585-30-0-1
39
38
40 38
A
35
B
111
420
Mou
ntin
g di
men
sion
X
Framebracket
Spindledrive
Locking actuator
Mountingbracket
Locking bracket
Opening system RWA 1000 S-Set (Synchro) [1]
consisting of:
1 locking actuator, 1 control module USKM, 2 spindle drives, mountings
100 mm
200 mm
300 mm
K-17588-10-0-1
K-17588-20-0-1
K-17588-30-0-1
B
Framebracket
Spindledrive
Connecting cable
Mou
ntin
g di
men
sion
X
A
ControlmoduleUSKM
Mountingbracket
Lockingactuator
Lockingbracket
40 38
38 35
111
420
39
[1] 2 hinges must be used on the side(s) where a drive is mounted.
51Edition 12.2009
Opening system RWA 1000
Order information – Opening systems and replacement parts
Description Stroke / Variant Order number
Opening system RWA 1000 S-Set (Synchro) [1]
consisting of:
1 locking actuator, 1 control module USKM, 2 spindle drives, mountings
100 mm
200 mm
300 mm
K-17587-10-0-1
K-17587-20-0-1
K-17587-30-0-1
39
B
1200
Framebracket
Spindledrive
Connecting cable
Mou
ntin
g di
men
sion
X
A
ControlmoduleUSKM
Locking bracket
Locking bracket
Mountingbracket
38
35
40 38
Lockingactuator
Mounting bracket set for opening system RWA 1000
standard
short
long
9-39105-00-0-1
(delivered with the
system)
9-39104-00-0-1
9-39106-00-0-1
15
0
104120
17
6
40
ø6 (
6x)
5
standard
90
84100
61
740
ø6 (
6x)
5
short
25
0
104120
61
740
ø6 (
6x)
5
long
[1] 2 hinges must be used on the side(s) where a drive is mounted.
52 Edition 12.2009
Product features Large opening widths up to 85°
Ideally suited for windows providing limited mounting space: the bracket mounted to the frame requires only 22 mm in height
Electronic limit stop switch and overload cut-off
Integral closing and opening sequence control
Ventilation control can be integrated as an option
Integral microprocessor controller
Synchronised tandem operation
Fire tested up to 300 °C
Opening system RWA 1050
Product features, Dimensioned drawing, Range of application, Technical data
Range of application
Minimum sash width / Opening angle
depending on stroke
Stroke (mm) 100 150 200 250
Min. sash width (mm)
(sash dimension B) 510 600 680 740
Opening angle, approx. * 35° 50° 70° 85°
* depending on mounting dimensions
Maximum sash height
Solo (mm) 1500
Synchro (mm) 2000
Dimensioned drawing
Open
ing
angl
e
171
min. 35
Technical data
Opening system RWA 1050
Nominal voltage 24 V DC
Nominal force 600 N
Current consumption 0,6 A
Breaking current 1,2 A
Speed 5,8 mm/s
Duty ratio 30 %
Locking pressure 12000 N
IP protection class 54
Connecting cable Silicone, 2,5 m, 2-core
Case Aluminium EV1 anodised
Max. switching current 3 A
53Edition 12.2009
Opening system RWA 1050
Order information – Opening systems
Description Stroke Order number
Opening system RWA 1050 Solo
with square spindle actuator and right-hand mounting bracket
consisting of: 1 spindle drive, 1 square spindle actuator, mountings
100 mm
150 mm
200 mm
250 mm
K-17799-10-R-1
K-17799-15-R-1
K-17799-20-R-1
K-17799-25-R-1
max
. 1500
Sash width SW
ELTRAL OAMounting bracket setRWA 1050 right-hand
Opening system RWA 1050 Solo
with square spindle actuator and left-hand mounting bracket
consisting of: 1 spindle drive, 1 square spindle actuator, mountings
100 mm
150 mm
200 mm
250 mm
K-17799-10-L-1
K-17799-15-L-1
K-17799-20-L-1
K-17799-25-L-1
max
. 15
00
Sash width SW
ELTRAL OA
Mounting bracket setRWA 1050 left-hand
54 Edition 12.2009
Description Stroke Order number
Opening system RWA 1050 S-Set (Synchro)
with square spindle actuator
consisting of:
2 spindle drives, 1 square spindle actuator, 1 control module USKM, mountings
100 mm
150 mm
200 mm
250 mm
K-17800-10-0-1
K-17800-15-0-1
K-17800-20-0-1
K-17800-25-0-1
Syn
chro
max
. 25
00
Sash width SW
ELTRAL OA
Mounting bracket setRWA 1050 right-hand
Mounting bracket setRWA 1050 left-hand
24 V DCmax. 1,6 A
Control moduleUSKM
Opening system RWA 1050 Solo
with right-hand locking actuator VA-1 R/4 and right-hand mounting brackets
consisting of: 1 spindle drive, 1 locking actuator, mountings
100 mm
150 mm
200 mm
250 mm
K-17801-10-R-1
K-17801-15-R-1
K-17801-20-R-1
K-17801-25-R-1
max
. 15
00
Sash width SW
Mounting bracket setRWA 1050 right-handELTRAL VA-1 R/4
Opening system RWA 1050
Order information – Opening systems
55Edition 12.2009
Opening system RWA 1050
Order information – Opening systems
Description Stroke Order number
Opening system RWA 1050 Solo
with left-hand locking actuator VA-1 L/4 and left-hand mounting bracket
consisting of: 1 spindle drive, 1 locking actuator, mountings
100 mm
150 mm
200 mm
250 mm
K-17801-10-L-1
K-17801-15-L-1
K-17801-20-L-1
K-17801-25-L-1
max
. 15
00
Sash width SW
ELTRAL VA-1 L/4
Mounting bracket setRWA 1050 left-hand
Opening system RWA 1050 S-Set (Synchro)
with locking actuator VA-2/12
consisting of: 2 spindle drives, 1 locking actuator, 1 control module USKM, mountings
100 mm
150 mm
200 mm
250 mm
K-17802-10-0-1
K-17802-15-0-1
K-17802-20-0-1
K-17802-25-0-1
Syn
chro
max
. 25
00
Sash width SW
Mounting bracket setRWA 1050 right-hand
Mounting bracket setRWA 1050 left-hand
24 V DCmax. 1,6 A
Control moduleUSKM
ELTRAL VA-2/12
56 Edition 12.2009
Opening system RWA 1050
Order information – Opening systems
Description Stroke Order number
Opening system RWA 1050 S-Set (Synchro)
with locking actuator VA-3/20
consisting of:
2 spindle drives, 1 locking actuator, 1 control module USKM, mountings
100 mm
150 mm
200 mm
250 mm
K-17858-10-0-1
K-17858-15-0-1
K-17858-20-0-1
K-17858-25-0-1
Syn
chro
max
. 30
00
Sash width SW
Mounting bracket setRWA 1050 right-hand
Mounting bracket setRWA 1050 left-hand
24 V DCmax. 1,6 A
Control moduleUSKM
ELTRAL VA-3/20
57Edition 12.2009
Product features Cost-efficient control of several window elements with one drive
Opening widths up to 300 mm, suitable for small sash heights from 350 mm
For sash weights up to 200 kg
Ideally suited for windows offering limited mounting space
High gasket pressure thanks to auto-matically and reliably locked stay arms
Overlap dimension 0 – 25 mm
Opening stay can be released easily for window cleaning
According to sash widths and weights, two drive variants with different motor power are available:
ELTRAL S 24 L / ELTRAL 300/24
Further features:
– Fire tested up to 300 °C
– Simple mounting, horizontal or vertical (rh/lh)
– Adjustable stroke for various opening widths
– Electronic limit stop switch and overload cut-off
Technical data
Fanlight opener VENTUS F 300
Product features, Technical data
Type of drive ELTRAL S 24 L ELTRAL 300/24
Nominal voltage 24 V DC
Nominal force 1200 N 3000 N
Current consumption 0,7 A 0,8 A
Stroke (adjustable) 50 mm / 70 mm [1] 40 – 70 mm [2]
Speed 0,9 mm/s 1,0 mm/s
Duty ratio 20 %
Cutoff Overload cut-off Limit stop switch
IP protection class 54
Connection 4-pole plug 4 x 0,75 mm2, 1,5 m
Dimensions (L x W x H) 210 x 36 x 76 mm 270 x 55 x 102 mm
Case Aluminium
[1] Factory setting = 50 mm stroke = 200 mm opening width (70 mm stroke = 300 mm opening width).[2] Factory setting = 40 mm stroke. When mounted with VENTUS F 300, the stroke must be set to 70 mm (= 300 mm opening width).
1
41
5
26
5331
29
58 Edition 12.2009
According to the directives of RAL, it is absolutely necessary that
bottom hung sashes must be fitted withcatch stays supple-menting the stan-dard fanlight fittings.
G.U security stays EURO-SOLID prevent damage that might arise from inappropriate attachment of the opening stays. Moreover, they provide great convenience when cleaning the tilted sash by holding it in the angle desired.
Fanlight opener VENTUS F 300
Dimensioned drawings, Installation dimensions, G.U security stay EURO-SOLID
Fanlight fittings VENTUS F 300 with electric drive ELTRAL S 24 L
Stroke 50M
210
76
Closing
15
18
193
36
3 12
32
29
37
89
130
22
Opening
M
Edge of sash up to M = min. 415 (without guide and cover profile = 390)
Minimum sash width SW 850 (without guide = 825)
Drive mounted at topOpening stay closed
Opening stay opened
G.U security stay EURO-SOLIDInstallation dimensions VENTUS F 300
59Edition 12.2009
14
00
16
00
18
00
20
00
22
00
24
00
26
00
28
00
30
00
32
00
34
00
36
00
100
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
12
00
10
00
80
0
70 k
g/m
2
60 k
g/m
2
50 k
g/m
2 (2x1
0)
40 k
g/m
2 (2
x8)
30 k
g/m
2 (2
x6)
30 kg/m 2 (2x6)
2 stays 3 stays
max
.D
im. "
S"
min
.
Maximum sash width SW
Fanlight fi ttings VENTUS F 300 with ELTRAL S 24 L Fanlight fi ttings VENTUS F 300 with ELTRAL 300/24
24
00
26
00
28
00
30
00
32
00
34
00
36
00
38
00
40
00
42
00
44
00
46
00
48
00
50
00
52
00
54
00
56
00
58
00
60
00
100
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
22
00
20
00
18
00
120 kg/m2
110 kg/m2
100 kg/m2
90 kg/m2
80 kg/m2
70 kg/m 2
60 kg/m 2
50 kg/m 2
60 kg/m2
Maximum sash width SW
2 stays 3 stays 4 stays 5 stays
max
.D
im. "
S"
min
.
Application range VENTUS F 300as a function of the centre of mass of the sash
Fanlight opener VENTUS F 300
Range of application
Dim. "S"
Application rangeELTRAL S 24 L / ELTRAL 300/24
Weights / heights / widths of sash permitted
VENTUS F 300 with ELTRAL S 24 L ELTRAL 300/24
Max. sash weight 200 kg
Max. weight of glazing [1] 70 kg/m2
Min. sash height
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
468 mm
350 mm
400 mm
350 mm
Min. sash width
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
620 mm
850 mm
605 mm
850 mm
Max. sash width 3600 mm 6000 mm
Space required for drive
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
39 mm
39 mm
57 mm
57 mm
Max. number of stays 3 5
Calculation exampleDimension “S”
Example:
Glazing 2 x 10 mm
Weight of glass 50 kg/m2
Sash width 2000 mm
Dim. “S” 25 – 60 mm possible
Sash weight
max. 200 kg
[1] Depending on Dim. “S” and sash width [2] on side [3] at top
60 Edition 12.2009
Description Mounting PU Order number
Electric drive ELTRAL S 24 L
Overload cut-off Vertical /
horizontal1 6-31734-00-0-*
Electric drive ELTRAL 300/24
Cut-off via limit stop switch
Horizontal 1 9-31021-00-0-*
Basic box without lever handle, with angular sash bracket Vertical 1 K-14320-00-0-*
Box of stay with angular sash bracket [1]Vertical /
horizontal1 K-13999-00-0-*
Bag of linkage parts
consisting of connecting rod, coupling and guide for electric drive ELTRAL S 24 L
Vertical /
horizontal1 K-14203-00-0-1
Bag of linkage parts
consisting of connecting rod, coupling and guide for electric drive ELTRAL 300/24Horizontal 1 K-14202-00-0-1
Connecting rod ø 12 mm
for electric drive ELTRAL 300/24Vertical 1 9-35331-00-0-1
End cap Horizontal 1 9-34479-00-0-*
Horizontal rod ø 10 mm / Cover profi le for horizontal rod
– Length 600 mm
– Length 1870 mm
– Length 3500 mm
Vertical /
horizontal
1
1
1
K-14001-06-0-*
K-14001-18-0-*
K-14001-33-0-*
Alternatively:
Horizontal rod ø 10 mm / Length 6000 mm
Cover profi le / Length 6000 mm
Vertical /
horizontal
1
1
9-23055-60-0-1
9-34497-60-0-*
G.U security stay EURO-SOLID
for bottom hung timber/PVC/aluminium windows
– Sash height 270 mm – 350 mm
– Sash height 351 mm – 500 mm
– Sash height 501 mm – 800 mm
– Sash height 801 mm – 1500 mm
Vertical /
horizontal
100
100
100
100
6-27995-01-0-1
6-27995-02-0-1
6-27995-03-0-1
6-27995-04-0-1
Bag of profi le-related accessories EURO-SOLID
– for bottom hung timber windows
– Packer for Euro groove 7/8 x 4, 6/8 x 4 / timber
– for bottom hung PVC windows
– for bottom hung aluminium windows
Vertical /
horizontal
20
100
K-14681-00-0-1
9-38819-00-0-1
upon request
upon request
Fanlight opener VENTUS F 300
Order information – Drives, Fanlight fittings, G.U security stay EURO-SOLID
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016) [1] When a second or more stays are required
1693°
408
421
24
16
10
1
40
61Edition 12.2009
Designed to open side hung window sashes and swing doors serving as RWA supply air opening:
The door drive TA 60 ensures the supply of air required for smoke extraction in the event of a fi re. A thermal lift is produced causing the smoke gases to rise and es-cape quickly.
In combination with an electric door ope-ner it is possible to use the door drive for unimpeded, convenient access.
Suitable for use on 2-leaf doors and panic doors.
Product features Compact size
Integral microprocessor controller
Potential-free contact
Electronic limit stop switch
Automatic overload cut-off
For door leaf widths from 450 mm
Direct mounting possible
For opening angles up to 93°
Delayed opening
Technical data
Door opening actuator ELTRAL TA 60
Product features, Dimensioned drawing, Technical data
Type of drive ELTRAL TA 60
Nominal voltage 24 V DC
Push/pull force 200 N / 600 N
Opening/closing speed 3°/s
Current consumption 1,4 A
Duty ratio 30 %
Opening torque (continuous / maximum) 180 Nm / 216 Nm
Closing torque 72 Nm
IP protection class 32
Potential-free contact max. 50 V; 0,5 A
Connecting cable Silicone, 5 m, 5-core
Case Aluminium EV1 anodised
Max. switching current 3 A
Dimensions 421 x 40 x 101 mm L x W x H
62 Edition 12.2009
Door opening actuator ELTRAL TA 60
Order information – Drives
Description Order number
ELTRAL TA 60
6-33971-00-0-1
ELTRAL TA 60 – S-Set for 2-leaf doors
consisting of 2 door drive units
with 2 different opening delays: active leaf with 5 s, passive leaf with 7 s delay
K-17860-00-0-0
Note:
The reliable everyday operation and secure locking of a door requires the installation of a multipoint lock with
electric opener such as, e.g., G.U-SECURY Automatic with A-opener [1]. The complete door assembly is actuated
via central control unit.
[1] For the comoplete range of multipoint locks and electric door openers please refer to our order catalogue “Safety Door Locks, Aluminium Thresholds and Door Closers”.
63Edition 12.2009
Door opening actuator ELTRAL TA 60
Order information – Mounting sets
Description Order number
Mounting bracket set for mounting on frame [1]
consisting of 3 angular brackets (one for drive-to-frame connection, two ones for stay-to-leaf connection)
K-17328-00-0-1
90°
100
40
50
50
50
75
105,5
max. 117min. 78
Mounting bracket for mounting to side opposite to hinges [2]
without fi xing screws
9-45614-00-0-1
24
100
50
7 11
33
61.5
85.5
[1] 2-leaf door assemblies require 2 sets. [2] 2 brackets required for each drive.
64 Edition 12.2009
6565Edition 12.2009
Control centres
Compact control centres RZ 2, RZ 5
Modular control centresRZ 10/2, RZ 24/4, RZ 24/8
Control centre extensions
66 Edition 12.2009
Central control units RZ (RWA)
The basic benefi ts of central control units RZ are:
Usability for both smoke exhaust and everyday ventilation
Integral backup batteries guaranteeing 72 hours operation in the event of a power failure
Electronic monitoring of cables leading to drives and detectors.
Extension of alarm and ventilation lines if required
Optional alarm forwarding to central building control system via potential-free contacts
Optional extensions such as, e.g., wind and rain detectors
Compact control centres Modular control centres
Centre RZ 2 RZ 5 RZ 10/2 RZ 24/4 RZ 24/8
Power output (A) 2 5 10 24 24
DimensionsW x H x D
(mm)350 x 250 x 120 350 x 250 x 120 500 x 500 x 200 600 x 600 x 250 800 x 800 x 250
Design compact compact modular modular modular
Max. no. of RWA groups 1 1 up to 2 up to 4 up to 8
Max. no. of ventilation groups 1 1 up to 2 up to 4 up to 8
Potential-free contacts for the transmission of alarm and
failure reports
optional optional standard standard standard
Signal input for external alarm
optional standard optional optional optional
Signal input for wind/rain detector
optional standard optional optional optional
Automatic ventilation „CLOSE“ optional standard optional optional optional
Linking of multiple control centres
– – optional optional optional
Backup batteries included included included optional(2 x 12 V)
optional(2 x 12 V)
Detail informationsee page
67 – 69 67 – 69 70 – 74 70 – 74 70 – 74
RWA control centres are available as com-pact or as extendable modular units. They are used wherever highest reliability and rapid extraction of smoke gases are needed.
RWA control centres are responsible for supplying, monitoring and controlling all the connected components (e.g., automatic de-tectors, manual alarms, electric drives) as well as for ventilation control.
Providing for the prompt actuation of smoke extraction openings to allow toxic gases to escape in the event of a fi re, RWA control centres constitute a primary element of preventive fi re protection.
Product overview
67Edition 12.2009
Product features Compact sheet-steel case, lockable
Integral microprocessor controller
Emergency power supply min. 72 hours
Failure indication
Line monitoring
Alarm monitoring
Integral runtime limitation [1]
Extension slots for
– wind and rain detector [2] [3]
– automatic closing in ventilation mode [2] [3]
– relay card to forward the potential-free signals “EMERGENCY-OPEN” and “Failure”
Adjustable charging voltage
Technical data
Compact central units RZ 2 and RZ 5
Product features, Technical data
Type RZ 2 RZ 5
Nominal voltage 24 V DC
Supply voltage 230 V AC, 50 Hz
Power output 2 A 5 A
Apparent output 48 VA 120 VA
Ambient temperature -5 °C up to +40 °C
Emergency power supply min. 72 hours
Backup batteries 2 Ah
Max. no. of groups 1 ventilation group / 1 RWA group
IP protection class 20
Case surface mounted: sheet-steel, white (RAL 1013) / fl ush mounted: sheet-steel, white (RAL 9010)
DimensionsSurface-mounted type
350 x 250 x 120 mm W x H x D
Flush-mounted type
330 x 445 x 90 mm W x H x D
[1] Only with type RZ 5 (with type RZ 2 as an option) [2] Only with type RZ 2 (with type RZ 5 as a standard) [3] Slot either for wind/rain detector or for automatic closing in ventilation mode
68 Edition 12.2009
Compact central units RZ 2 and RZ 5
Order information – Control centres
Description Type Order number
RZ 2
Surface-mounted
Flush-mounted
6-30771-00-0-0
9-42151-00-0-0
Standard– Backup batteries
– Failure indication
Optional
– Potential-free contacts to forward alarm and failure signals
– Signal input for external alarm
– Wind/rain card (WR 71)
– “Automatic close” card (ZA 71)
RZ 5
Surface-mounted
Flush-mounted
9-41996-00-0-0
9-42070-00-0-0
Standard
– Backup batteries
– Failure indication
– Signal input for external alarm
– Wind/rain card
– “Automatic close” card
– Ventilation control
Optional – Potential-free contacts to forward alarm and failure signals
69Edition 12.2009
Compact central units RZ 2 and RZ 5
Order information – Control centre extensions and accessories
Description Type Order number
Wind / rain card WR 71
RZ 2 9-42080-00-0-0
Specifi cation:
– Switching threshold adjustable to various wind speeds
– Switching status indication (wind/rain)
– Operating status controllable externally via potential-free contacts
Relay card REL 65
RZ 2 / RZ 5 9-42000-00-0-0for “EMERGENCY OPEN” and “Failure” signal transmission
– Potential-free contact (max. 48 V / 1 A)
– Slot for “Failure” and “EMERGENCY OPEN”
“Automatic close” card ZA 71
RZ 2 9-42072-00-0-0
Specifi cation:
– Adjustable closing time
– Operating status indication
– Checkbutton to show or change settings
Runtime module LZM
RZ 2 9-42074-00-0-0for the electronic stroke limitation of ventilation drives
– Setting range 5 – 999 s
End of line module 70 MRZ 2 / RZ 5 9-42071-00-0-0
to close off the last line or drive terminal jack
Maintenance card
RZ 2 / RZ 5 9-42001-00-0-0for the indication of the annually required servicing
(at 15 months’ intervals)
Relay for function transmissionRZ 2 / RZ 5 9-42090-00-0-0
for the control of external devices (max. 230 V / 10 A)
Connecting module – Ventilation
RZ 2 / RZ 5 9-42077-00-0-0
for the conversion of continuous signals into short-time pulses
Application:
– Room temperature sensor / hygrostat / conservatory controller / time switch
– For the reception of building management system signals
Replacement key RZ 2 / RZ 5 9-45747-00-0-0
70 Edition 12.2009
Product features Compact sheet-steel case, lockable
Integral microprocessor controller
Emergency power supply min. 72 hours
Failure indication
Line monitoring
Alarm monitoring
Extension slots for
– wind and rain detector– automatic closing in ventilation mode– relay card to forward the potential- free signals “EMERGENCY-OPEN” and “Failure”
Linking of multiple control centres
Extension of alarm and ventilation lines if required
Integral runtime limitation
Variable RWA and ventilation group arrangements
Technical data
Modular central units RZ 10/2, RZ 24/4 and RZ 24/8
Product features, Technical data
Type RZ 10 RZ 24/4, RZ 24/8
Nominal voltage 24 V DC
Supply voltage 230 V AC, 50 – 60 Hz
Output 10 A 24 A
Apparent output 250 VA 580 VA
Emergency power supply min. 72 Stunden
Backup batteries 24 Ah 38 Ah
Max. no. of groups 2 ventilation groups / 2 RWA groupsRZ 24/4: 4 ventilation groups / 4 RWA groupsRZ 24/8: 8 ventilation groups / 8 RWA groups
IP protection class 54
Ambient temperature -5 °C up to +40 °C
Case Sheet-steel, gravel grey (RAL 7032)
DimensionsRZ 10/2 – Surface-mounted type
500 x 500 x 200 mm W x H x D
RZ 24/4 – Surface-mounted type
600 x 600 x 250 mm W x H x D
RZ 24/8 – Surface-mounted type
800 x 800 x 250 mm W x H x D
71Edition 12.2009
Modular central units RZ 10/2, RZ 24/4 and RZ 24/8
Order information – Control centres
Description Type Order number
RZ 10/2 [1]
Surface-mounted 9-44730-00-0-0Standard
– Backup batteries
– Motherboard GP 70, 10 A, 2 free slots
– Connection terminals
– Device fuses
– Potential-free contacts to forward alarm and failure signals
– Control card STK 70 with indication of power supply failure,
line feed failure, collective faults and collective triggering
Optional see “Order information – Control centre extensions”
RZ 24/4 [1]
Surface-mounted 6-34565-00-0-0
Standard
– Motherboard GP 70, 24 A, 4 free slots
– Connection terminals
– Device fuses
– Potential-free contacts to forward alarm and failure signals
– Control card STK 70 with indication of power supply failure,
line feed failure, collective faults and collective triggering
Optional see “Order information – Control centre extensions”
Important: The batteries (12 V, 24 Ah, order number 9-40287-00-0-0) must be ordered separately; see “Order information – RWA accessories”.
RZ 24/8 [1]
Surface-mounted 9-44711-00-0-0
Standard
– Motherboard GP 70, 24 A, 8 free slots
– Connection terminals
– Device fuses
– Potential-free contacts to forward alarm and failure signals
– Control card STK 70 with indication of power supply failure,
line feed failure, collective faults and collective triggering
Optional see “Order information – Control centre extensions”
Important: The batteries (12 V, 38 Ah, order number 9-40288-00-0-0) must be ordered separately; see “Order information – RWA accessories”.
[1] For the fulfi lment of the basic functions it is necessary to install group card RWA 70 or RWA 70 V on the motherboard. For ordering the group cards see “Order information – Control centre extensions and accessories”.
72 Edition 12.2009
Modular central units RZ 48/4, RZ 48/8 and RZ 72/8
Order information – Control centres with increased power output
Description Type Order number
RZ 48/4 [1]
Surface-mounted 6-35077-00-0-0Power output 48 A
Max. no. of groups 4 ventilation groups / 4 RWA groups
RZ 48/8 [1]
Surface-mounted 6-35078-00-0-0Power output 48 A
Max. no. of groups 8 ventilation groups / 8 RWA groups
RZ 72/8 [1]
Surface-mounted 6-35079-00-0-0Power output 72 A
Max. no. of groups 8 ventilation groups / 8 RWA groups
[1] Further product features same as those of modular central unit RZ 24
73Edition 12.2009
Modular central units RZ 10/2, RZ 24/4 and RZ 24/8
Order information – Control centre extensions and accessories
Description Type Order number
Group card RWA 70 (current consumption max. 6 A) [1]
RZ 10 / RZ 24 9-39951-00-0-0
Specifi cation:
– 2 separate – closed current controlled – alarm lines for max. 10 detectors, each
– Programmable failure and triggering indication
– 1 closed current controlled drive line with separate failure indication
– 1 ventilation line for max. 10 ventilation switches with the corresponding indications
– Selection between locking and dead man’s operating mode
– External signals (from building management or fi re alarm system) can be processed
on alarm line B
– “EMERGENCY OPEN” function in case of drive line failure
– Reclocking (regeneration) of signal pulses for at least 15 smoke extraction opening
cycles within 30 minutes
– End of line module 70 M to close off the last line or drive terminal jack
Group card RWA 70 V (current consumption max. 10 A) [1]
RZ 10 / RZ 24 9-42082-00-0-0Specifi cation:
– same as group card RWA 70 – 9-39951-00-0-0
Ventilation card LE 70 (current consumption max. 6 A)
RZ 10 / RZ 24 9-39952-00-0-0
Specifi cation:
– 1 ventilation line for max. 10 ventilation switches
– Selection between locking and dead man’s operating mode
– Potential-free contacts for external triggering (e.g. building management system)
– Connection of external “Ventilation OPEN / CLOSED” indications
– End of line module 70 M to close off the last line or drive terminal jack
Ventilation card LE 70 V (current consumption max. 10 A)
RZ 10 / RZ 24 9-39953-00-0-0Specifi cation:
– same as ventilation card LE 70 – 9-39952-00-0-0
Wind / rain card WR 70 N
RZ 10 / RZ 24 9-45301-00-0-0
Specifi cation:
– Switching threshold adjustable to various wind speeds
– Switching status indication (wind/rain)
– Operating status controllable externally via potential-free contacts
Master-slave card MS-PE 70 [2] [3]
RZ 10 / RZ 24 9-42118-00-0-0
Specifi cation:
– 2 group cards (RWA 70 or RWA 70 V) or different control centres can be combined
to one group
– Signal transmission “EMERGENCY OPEN” to subordinate central units
– Indication of slave control unit failures
[1] Important: It is not permitted to use different types of group cards in one central unit.[2] Only required for the master central unit. [3] When using the Master-Slave card MS-PE 70, a group card RWA 70 or RWA 70 V is required for each central unit connected.
74 Edition 12.2009
Modular central units RZ 10/2, RZ 24/4 and RZ 24/8
Order information – Control centre extensions and accessories
Description Type Order number
Motherboard extension GPE 70RZ 24 9-42265-00-0-0
Motherboard GP 70 slot extension
Relay card REL 65
RZ 10 / RZ 24 9-42000-00-0-0for “EMERGENCY OPEN” and “Failure” signal transmission
– Potential-free contact (max. 48 V / 1 A)
– Slot for “Failure” and “EMERGENCY OPEN”
Runtime module LZM
RZ 10 / RZ 24 9-42074-00-0-0for the electronic stroke limitation of ventilation drives
– Setting range 5 – 999 s
End of line module 70 MRZ 10 / RZ 24 9-42071-00-0-0
to close off the last line or drive terminal jack
Maintenance card
RZ 10 / RZ 24 9-42001-00-0-0for the indication of the annually required servicing
(at 15 months’ intervals)
Relay for function transmissionRZ 10 / RZ 24 9-42090-00-0-0
for the control of external devices (max. 230 V / 10 A)
Handover module
RZ 10 / RZ 24 9-42087-00-0-0for transmitting signals to a building management system
– with 3 disconnect terminals
Takeover module
RZ 10 / RZ 24 9-42088-00-0-0for receiving signals and transmitting them to the control centre
– with 2 disconnect terminals
Connecting module – Ventilation
RZ 10 / RZ 24 9-42077-00-0-0
for the conversion of continuous signals into short-time pulses
Application:
– Room temperature sensor / hygrostat / conservatory controller / time switch
– For the reception of building management system signals
Connecting module – Smoke switch control centre
RZ 10 / RZ 24 9-40077-00-0-0for connecting external normally-open contacts to alarm line B
– Monitoring of the closed-circuit current of the control centre
Replacement key RZ 10 / RZ 24 9-45748-00-0-0
75Edition 12.2009
Accessories for RWA installations
Manual alarm devices Automatic alarm devices Wind and rain detector Ventilation switches Indicating labels
76 Edition 12.2009
Accessories for RWA installations
Order information – Manual alarm devices
Description Finish Order number
RWA pushbutton HSE
Primary RWA pushbutton for manual triggering of an RWA alarm
signal and signal transmission to the RWA control centre
Product features:
– Buttons “EMERGENCY-OPEN” and “CLOSE”
– Indications: “EMERGENCY-OPEN”, operating status and failure
– Dimensions: 130 x 130 x 32 mm (W x H x D)
red
grey
yellow
blue
orange
9-41997-00-0-9
9-41997-00-0-1
9-41997-00-0-3
9-41997-00-0-0
9-41997-00-0-9
RWA pushbutton HSE-N
Secondary RWA pushbotton for manual triggering of an RWA alarm
signal and signal transmission to the RWA control centre
Product features:
– Button: “EMERGENCY-OPEN”
– Indication: “EMERGENCY-OPEN”
– Dimensions: 130 x 130 x 32 mm (W x H x D)
red
grey
yellow
blue
orange
9-41998-00-0-9
9-41998-00-0-1
9-41998-00-0-3
9-41998-00-0-0
9-41998-00-0-9
Replacement key for RWA pushbutton HSE 9-45611-00-0-6
Frame for in-wall mounting of RWA pushbutton HSE
– Wall recess dimensions: 140 x 140 x 30 mm
– Outer dimensions of frame: 171 x 171 x 26 mm light grey
(RAL 7035)9-42236-00-0-0
Replacement glass for RWA pushbutton HSE 9-42235-00-0-0
Adhesive label indicating “Smoke Vent”
for RWA pushbutton HSE9-42233-00-0-0
77Edition 12.2009
Accessories for RWA installations
Order information – Automatic alarm devices
Description Order number
Optical smoke switch SSD 521 [1]
Product features:
– Voltage range: 18 – 30 V DC
– Current consumption: 0,1 mA
– With mounting socket
– Visual alarm indication
– Dimensions: ø 120 mm x 80 mm
– IP protection class: 44
– Colour: electro white
6-32355-00-0-0
Maximum heat detector [2]
Product features:
– Voltage range: 18 – 30 V DC
– Current consumption: 0,15 mA
– With mounting socket
– Visual alarm indication
– Dimensions: ø 120 mm x 80 mm
– IP protection class: 44
– Colour: electro white
6-32356-00-0-0
Protection against thrown balls
(for smoke detector SSD 521 and maximum heat detector)9-42264-00-0-0
[1] Only for dust-free spaces.[2] Only for dry spaces. Connection to alarm line only !
78 Edition 12.2009
Accessories for RWA installations
Order information – Wind/rain detector, wind/rain evaluator
Description Order number
Rain detector 24 V AC/DC
consisting of:
– Sensor
– Operation indicator LED
– Integral heater
– 4 m connection cable, output approx. 150 mA
Functional mode:
When rain or snow starts falling, the sensor transmits a “closing” signal to a building
management system or to a RWA/Ventilation control centre. The heated sensor surface
(heater with a 5 minutes’ switch-on delay) ensures reliable functioning.
9-39062-00-0-0
Wind and rain detector
consisting of:
– Wind sensor
– Rain sensor 24 V AC/DC
– Bracket for pole or wall mounting
– Clamping ring
Functional mode:
With wind speeds < 1 m/s, all RWA supply air openings are opened (leeward side of buil-
ding); with wind speeds > 1 m/s, they are closed (windward side of building). The control
of the wind and rain detector is based on arithmetically averaged values measured over a
period of 10 minutes.
K-15331-00-0-0
Wind/rain evaluator WRAG 2
– Allows for the connection of wind/rain detectors to several control centres
– Supply voltage: 230 V AC, 50 Hz, 5 A
– Separate connection of a normally-open contact possible (e.g. ventilation switch,
timer switch)
– Switch-on delay with wind and rain, and switch-off delay with wind, to prevent constant
on/off switching
– 4 adjustable DIP switches for signal transmission via relay outputs (2 x 1 Um)
– Direct connection of drives (max. total current consumption 5 A)
– Switching threshold adjustable to wind speeds from 2.5 to 20 m/s
– LEDs indicating wind, rain, operating status
– Surface-mount case for top hat rail 35 mm
– Case dimensions (W x H x D): 105 x 86 x 58 mm
9-42268-00-0-0
Relais for wind/rain evaluator WRAG 2
for multiple contacts
2 contacts with 8 A maximum contact load
9-42269-00-0-0
79Edition 12.2009
Accessories for RWA installations
Order information – Ventilation switches and indicating labels
Description Order number
Ventilation switch “OPEN – CLOSE” – surface-mounted
Case dimensions: 80 x 80 x 44 mm (W x H x D)
Colour: pearl white RAL 10136-24372-00-0-0
Ventilation switch “OPEN – CLOSE” – fl ush mounted
(for ø 60 mm standard fl ush box)
Case dimensions: 80 x 80 x 35 mm (W x H x D)6-24373-00-0-0
Ventilation key switch “OPEN – STOP – CLOSE” – fl ush mounted
Prepared for profi le half cylinder
Case dimensions: 80 x 152 x 35 mm (W x H x D)6-25838-00-0-0
Indication label “Smoke Vent”
– In compliance with DIN 4066
– Aluminium
– Dimensions: 210 x 75 x 1 mm (W x H x D)
9-22277-00-0-0
Indication label “Ventilation”
– Aluminium
– Dimensions: 210 x 75 x 1 mm (W x H x D)
9-25546-00-0-0
80 Edition 12.2009
Accessories for RWA installations
Order information – Timer switch, voltage regulator, test kit, backup batteries
Description Order number
Timer switch with day/week programme and power reserve [1]
for time-related opening and closing of ventilation sashes/leaves/fl aps
– Suitable for combination with temperature-dependent control devices, e.g., for controlled
night cooling (taking into account winter and summer time)
9-45612-00-0-0
Voltage regulator
to adjust the battery charging voltage9-42085-00-0-0
Test kit
for 24 V DC/230 V AC drives
Functions:
– Digital display of maximum and instantaneous current
– Separate 24 V and 230 V power connections
– Push-to-lock switch and dead man’s switch
– Integrated battery pack
K-17736-00-0-6
Backup batteries [2]
– 12 V, 2,2 Ah
– 12 V, 6,0 Ah
– 12 V, 10,0 Ah
– 12 V, 17,0 Ah
– 12 V, 24,0 Ah
– 12 V, 38,0 Ah
for RWA control centre
RZ 2
RZ 5 / RZ 10
RZ 10 / RZ 24
RZ 24 (for max. 2 – 4 groups)
RZ 24 (for max. 4 – 6 groups)
RZ 24 (for max. 6 – 8 groups)
9-40284-00-0-0
9-40285-00-0-0
9-40286-00-0-0
9-45327-00-0-0
9-40287-00-0-0
9-40288-00-0-0
[1] To provide for the “AUTOMATIC OPEN” function, the compact control centres RZ 2 / RZ 5 need the connecting module “Ventilation” in addition.[2] Batteries must always be ordered by pairs.
81Edition 12.2009
Ventilation Systems (230 V AC)
Chain drives ELTRAL K
Spindle drive ELTRAL S
Rack and pinion drive ELTRAL Z
Fanlight openingsystems
Ventilation control centres LZ 1 / LZ 6
Accessories for ventilation systems
82 Edition 12.2009
Chain drives ELTRAL K
Chain drives ELTRAL K25 KS 30/40 [1] K30 K60
Operating voltage 230 V AC 110 / 230 V AC 110 / 230 V AC 230 V AC
Pushing force (N) 250 [2] 300 [2] 300 [2] 600 [2]
Pulling force (N) 250 300 300 600
Current consumption (A) 0,2 0,12 0,16 0,2
Opening width (stroke) (mm) 200 / 300 / 400 110 / 200 / 300 / 400 200 / 300 / 400 / 500 250 / 400
IP protection class 32 30 32 32
Ambient temperature -5 °C up to +75 °C -5 °C up to +65 °C -5 °C up to +65 °C -5 °C up to +75 °C
Suitable for roof-lights no no yes yes
Synchronising control optional optional optional optional
Concealed installation no no no no
DimensionsW x H x D
(mm) 435x26x41(stroke 200)
386,5x38,1x58,5(all strokes)
456x43x60(all strokes)
537x40x56(stroke 250)
Connecting cable Silicone, 3 m, 4-core
2 m, 3-core (Solo)2,5 m, 5-core (Synchro)
Silicone;2 m, 3-core (Solo)
2,5 m, 5-core (Synchro)
Silicone, 5 m,6-core
Detail informationsee page
83 / 84 / 91 85 / 86 / 91 87 / 88 / 92 89 / 90 / 92
Electric motor chain drives are ideally suited in the context of centrally controlled room ventilation.
Thanks to their compact design and the great number of face-fi xed or concealed mounting variants, they can be used – al-most regardless of the installation condi-tions – on inward or outward opening top or bottom hung windows, parallel offset windows, projecting top hung windows, horizontal or vertical pivoting windows, side hung windows, and roof-lights.
Intelligent electronics allows for the syn-chronised control 2 drives, also in combina-tion with locking actuators.
Product overview
[1] Chain drive with plastic case[2] Depending on stroke
83Edition 12.2009
145
41
26
12
13
13
Total length L
7
12 6
12
Stroke
Product features Compact size
Stainless steel chain
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Automatic overload cut-off
Suitable for small sash heights
Total length 200 mm stroke L = 435 mm
300 mm stroke L = 480 mm
400 mm stroke L = 530 mm
Technical data
Chain drive ELTRAL K25
Product features, Dimensioned drawing, Technical data
Type of drive ELTRAL K25
Nominal voltage 230 V AC
Push/pull force 250 N / 250 N [1]
Current consumption 0,2 A
Stroke speed 8 mm/s
Duty ratio 30 %
Locking pressure 3000 N
IP protection class 32
Connecting cable Silicone, 3 m, 4-core
Case Aluminium EV1 anodised
Dimensioned drawing
Dimensions L x 26 x 41 mm L x H x D
[1] Depending on stroke Note: Order information see page 91
84 Edition 12.2009
Chain drive ELTRAL K25
Application range [1]
350
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
500
425
750
1000
1250
1500
1750
K25K25 Synchro
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
Application diagram Thrust diagram
100 200 300 400
100
200
300
500 600
0
0
Th
rust
(N
)
Stroke (mm)
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.
38
.1
386.5
51
min
. 37
28
.5
58
.5
ø46
8.4
ø10
85Edition 12.2009
Chain drive ELTRAL KS 30/40
Product features, Dimensioned drawing, Technical data
Product features Compact size
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Automatic overload cut-off
Suitable for small sash heights
Variable stroke adjustment
Automatic gasket relief
Technical data
Type of drive ELTRAL KS 30/40
Nominal voltage 110 / 230 V AC
Push/pull force 300 N
Current consumption 0,12 A
Opening width (adjustable) 110 mm / 200 mm / 300 mm / 400 mm
Stroke speed 12 mm/s
Duty ratio 30 %
Locking pressure 1000 N
IP protection class 30
Connecting cable 2 m, 3-core (Solo) / 2,5 m, 5-core (Synchro)
Case PVC
Dimensioned drawing Dimensions 386,5 x 38,1 x 58,5 mm L x H x D
Note: Order information see page 91
86 Edition 12.2009
Chain drive ELTRAL KS 30/40
Application range [1]
ELTRAL KS 30/40 ELTRAL KS 30/40 Remote
Application diagrams
Thrust diagram
ELTRAL KS 30/40
ELTRAL KS 30/40 Remote
50
0
40
0
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
20
00
19
00
21
00
22
00
23
00
24
00
25
00
26
00
500
250
750
1000
1250
1500
KS 30/40 KS 30/40 Synchro
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm4
00
50
0
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
500
250
750
1000
1250
1500
KS 30/40 Remote
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
100 200 300 400
100
200
300
400
0
0
Th
rust
(N
)
Stroke (mm)
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.
456
43
60
228
28
.5
30
87Edition 12.2009
Chain drive ELTRAL K30
Product features, Dimensioned drawing, Technical data
Product features Compact size
Integral microprocessor controller
Synchronised tandem operation
Electronic limit stop switch
Independent of sash overlap dimension
Automatic overload cut-off
Suitable for small sash heights
Variable stroke adjustment
Automatic gasket relief
Technical data
Type of drive ELTRAL K30
Nominal voltage 230 V AC
Push/pull force 300 N
Current consumption 0,16 A
Opening width (adjustable) 200 mm / 300 mm / 400 mm / 500 mm
Stroke speed 12,5 mm/s
Duty ratio 30 %
Locking pressure 2000 N
IP protection class 32
Connecting cable Silicone; 2 m, 3-core (Solo) / 2,5 m, 5-core (Synchro)
Case Zinc die cast
Dimensioned drawing Dimensions 456 x 43 x 60 mm L x H x D
Note: Order information see page 92
88 Edition 12.2009
Chain drive ELTRAL K30
Application range [1]
50
0
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
19
00
20
00
21
00
22
00
23
00
24
00
25
00
26
00
500
250
750
1000
1250
1500
K30 K30 Synchro
Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
Application diagram Thrust diagram
100 200 300 400 500
100
200
300
400
0
0
Th
rust
(N
)
Stroke (mm)
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.
89Edition 12.2009
Product features Compact size
Stainless steel chain
Integral microprocessor controller
Electronic limit stop switch
Automatic overload cut-off
Pivotable mountings allow for small sash heights from 350 mm
Emergency release
Total length 250 mm stroke L = 537 mm
400 mm stroke L = 613 mm
Chain drive ELTRAL K60
Product features, Dimensioned drawing, Technical data
Dimensioned drawing
Dimensions L x 40 x 56 mm L x H x D
Technical data
Type of drive ELTRAL K60
Nominal voltage 230 V AC
Push/pull force 600 N [1]
Current consumption 0,2 A
Stroke speed 10 mm/s
Duty ratio 30 %
Locking pressure 3000 N
IP protection class 32
Connecting cable Silicone, 5 m, 6-core
Case Aluminium EV1 anodised
40
16
230
1819
Total length L56
[1] Depending on stroke Note: Order information see page 92
90 Edition 12.2009
100 200 300 400 500 600 700 800 900 1000
100
200
300
400
500
600
0
0
Th
rust
(N
)
Stroke (mm)
55
06
00
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
500
425
750
1000
1250
1500
K60Sa
sh h
eig
ht
(SH
), m
m
Sash width (SW), mm
Application diagram Thrust diagram
Chain drive ELTRAL K60
Application range [1]
[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.
91Edition 12.2009
Chain drives ELTRAL K25 / ELTRAL KS 30/40
Order information – Drives
Description Stroke Order number
ELTRAL K25200 mm
300 mm
400 mm
K-17647-20-0-1
K-17647-30-0-1
K-17647-40-0-1
ELTRAL K25 Synchro
consisting of 2 chain drives
200 mm
300 mm
400 mm
K-17582-20-0-1
K-17582-30-0-1
K-17582-40-0-1
ELTRAL KS 30/40 110 mm
200 mm
300 mm
400 mm
K-17433-00-0-*
ELTRAL KS 30/40 Synchro
consisting of 2 chain drives 110 mm
200 mm
300 mm
400 mm
K-17435-02-0-*
ELTRAL KS 30/40 Remote 110 mm
200 mm
300 mm
400 mm
K-17437-00-0-*
Radio remote control with holder
for programming up to 4 individual drives
K-17439-00-0-0
Note: Mounting sets must be ordered separately – see catalogue section “24 V DC Drives”.
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)
92 Edition 12.2009
Chain drives ELTRAL K30 / ELTRAL K60
Order information – Drives
Description Stroke Order number
ELTRAL K30 200 mm
300 mm
400 mm
500 mm
K-17834-00-0-*
ELTRAL K30 Synchro
consisting of 2 chain drives 200 mm
300 mm
400 mm
500 mm
K-17835-00-0-*
ELTRAL K60250 mm
400 mm
K-17649-25-0-1
K-17649-40-0-1
Note: Mounting sets must be ordered separately – see catalogue section “24 V DC Drives”.
93Edition 12.2009
Spindle drive ELTRAL S / Rack and pinion drive ELTRAL Z
Electromotive spindle or rack and pinion drives mounted on large and heavy roof-lights or façade openings provide comfor-table automated room ventilation.
Spindle drive and rack and pinion drive ELTRAL
S80 Z60
Operating voltage 230 V AC ± 15 % 230 V AC ± 15 %
Pushing force (N) 800 600
Pulling force (N) 800 600
Current consumption (A) 0,12 0,23
Opening width (stroke) (mm) 300 / 500 / 750 180 / 230 / 350 / 550 / 750 / 1000
IP protection class 54 55
Ambient temperature -5 °C up to +75 °C -5 °C up to +65 °C
Synchronising control no mechanical
Dimensions W x H x L (mm) 43 x 76 x (190 mm + stroke) 43 x 142 x (135 mm + stroke)
Connecting cable Silicone, 1 m, 6-core 2 m, 3-core
Detail informationsee page
94 – 96 97 – 98
Product overview
94 Edition 12.2009
23
ø16
40
Installation dimension 190 mm + stroke
ø6
76
Product features Compact size
Synchronised tandem operation
Electronic limit stop switch
Automatic overload cut-off
Total length 300 mm stroke L = 490 mm
500 mm stroke L = 690 mm
750 mm stroke L = 940 mm
Technical data
Spindle drive ELTRAL S80
Product features, Dimensioned drawing, Technical data
Type of drive ELTRAL S80
Nominal voltage 230 V AC
Push/pull force 800 N
Current consumption 0,12 A
Stroke speed 7 mm/s
Duty ratio 30 %
Locking pressure 3500 N
IP protection class 54
Connecting cable Silicone, 1 m, 6-core
Case Aluminium EV1 anodised
Dimensioned drawing
Dimensions (190 + stroke) x 43 x 76 mm L x H x D
95Edition 12.2009
Spindle drive ELTRAL S80
Order information – Drives and mounting sets
Description Stroke / Joinery Order number
ELTRAL S80
300 mm
500 mm
750 mm
9-42094-30-0-1
9-42094-50-0-1
9-42094-75-0-1
Mounting set S/230 V for roof-lights
Aluminium K-17770-00-0-1
Mounting set RS/230 V for roof-lights
Aluminium K-17772-00-0-1
96 Edition 12.2009
Description Joinery Order number
Mounting set W/230 V for roof-lights
Aluminium K-17773-00-0-1
Mounting set / universal
Aluminium K-17774-00-0-1
19
32
46
40
Spindle drive ELTRAL S80
Order information – Mounting sets
97Edition 12.2009
Rack and pinion drive ELTRAL Z60
Product features, Dimensioned drawing, Technical data
Product features Compact size
Galvanised thrust tube
Tandem operation with connecting rod
Electronic limit stop switch
Automatic overload cut-off
Multiple operation with up to 4 drives
Note:
With heavy and large sashes it is possible to operate several drives in a row. A rack and pinion follower can be used as additional opening/locking element (both in single-drive and multiple-drive operating mode). Synchro-nisation between the drives or between drive and follower is effected by means of a mecha-nical connecting rod.
Total length 180 mm stroke L = 315 mm
230 mm stroke L = 365 mm
350 mm stroke L = 485 mm
550 mm stroke L = 685 mm
750 mm stroke L = 785 mm
1000 mm stroke L = 1135 mm
Dimensioned drawing
Dimensions 43 x 142 x (135 + stroke) mm W x H x L
Technical data
Type of drive ELTRAL Z60
Nominal voltage 230 V AC
Push/pull force 600 N
Current consumption 0,23 A
Stroke speed 11 mm/s
Duty ratio 30 %
Locking pressure 3000 N
IP protection class 55
Connecting cable 2 m, 3-core
25.517
33.6
32
Ø12
48
135 + stroke
43
54
260
45
97.5
98 Edition 12.2009
Rack and pinion drive ELTRAL Z60
Order information – Drives
Description Stroke / Length Order number
ELTRAL Z60
180 mm
230 mm
350 mm
550 mm
750 mm
1000 mm
K-17845-18-0-1
K-17845-23-0-1
K-17845-35-0-1
K-17845-55-0-1
K-17845-75-0-1
K-17845-01-0-1
Rack and pinion follower ELTRAL Z60 180 mm
230 mm
350 mm
550 mm
750 mm
1000 mm
K-17844-18-0-1
K-17844-23-0-1
K-17844-35-0-1
K-17844-55-0-1
K-17844-75-0-1
K-17844-01-0-1
Connecting rodL = 1000 mm
L = 1500 mm
L = 2000 mm
L = 2500 mm
9-45469-10-0-1
9-45469-15-0-1
9-45469-20-0-1
9-45469-25-0-1
Ø1
3
Ø1
1
24°
L
99Edition 12.2009
Fanlight opening systems
Fanlight opener VENTUS F 200 [*]
Fanlight openerVENTUS F 300 [*]
Easy and comfortable fanlight ventilation is provided by the fanlight fi ttings VENTUS F 200 and F 300 for bottom hung inward opening sashes, especially in combination with the electric drives ELTRAL S 230 or ELTRAL 300 E1.
Fanlightopening systems
VENTUS F 200 / VENTUS F 300with ELTRAL S 230 E / ELTRAL S 230 L
VENTUS F 200 / VENTUS F 300with ELTRAL 300 E1
Mains voltage 230 V AC ± 15 % 230 V AC ± 15 %
Thrust (N) 1200 3000
Duty ratio (%) 20 100
Current consumption (A) 0,15 0,1
Maximum stroke (mm) 70 40 – 100
IP protection class 50 54
Synchronising control no no
Dimensions L x W x H (mm) 210 x 36 x 76 270 x 55 x 102
Connection 4-pole plug Silicone, 1,5 m, 4-core
Detail informationsee page
100 – 105 100 – 105
Product overview
[*] For further information see our order catalogues “Builder’s Hardware for timber/PVC/aluminium windows and patio doors”
100 Edition 12.2009
Product features Cost-efficient control of several window elements with one drive
Opening widths up to 200 mm / 300 mm, suitable for small sash heights from 300 mm / 350 mm
For sash weights up to 80 kg / 200 kg
Ideally suited for windows offering limited mounting space
High gasket pressure thanks to auto-matically and reliably locked stay arms
Overlap dimension 0 – 25 mm
Individually dosed ventilation thanks to continuously variable and lockable opening angles
Opening stay can be released easily for window cleaning
According to sash widths and weights, two drive variants with different motor power are available:
ELTRAL S 230 / ELTRAL 300 E1
Further features:
– Simple mounting, horizontal or vertical (rh / lh)
– Adjustable stroke for various opening widths
– Electronic limit stop switch and overload cut-off
Fanlight openers VENTUS F 200 / VENTUS F 300
Product features, Technical data
Technical data
Type of drive ELTRAL S 230 E ELTRAL S 230 L ELTRAL 300 E1
Nominal voltage 230 V AC 230 V AC
Nominal force 1200 N 3000 N
Current consumption 0,15 A 0,1 A
Stroke (adjustable) 50 mm / 70 mm [1] 40 – 70 mm [2]
Speed 0,9 mm/s 1 mm/s
Duty ratio 20 % 100 %
Synchronising control no no
Cutoff Electronic Overload cut-off Limit stop switch
Overload protection Thermostatic switch Thermostatic switch
IP protection class 50 54
Connection 4-pole plug Silicone, 1,5 m, 4-core
Dimensions (L x W x H) 210 x 36 x 76 mm 270 x 55 x 102 mm
Case Aluminium Aluminium
[1] Factory setting: 50 mm stroke = 200 mm opening width (VENTUS F 200); when mounted with VENTUS F 300, the stroke must be set to 70 mm (= 300 mm opening width).[2] Factory setting = 40 mm stroke. When mounted with VENTUS F 200, the stroke must be set to 50 mm (200 mm opening width) When mounted with VENTUS F 300, the stroke must be set to 70 mm (300 mm opening width)
26
12
1
20
4
3150
1
41
5
26
5331
29
101Edition 12.2009
According to the directives of RAL, it is absolutely necessary that
bottom hung sashes must be fitted withcatch stays supple-menting the stan-dard fanlight fittings.
G.U security stays EURO-SOLID prevent damage that might arise from inappropriate attachment of the opening stays. Moreover, they provide great convenience when cleaning the tilted sash by holding it in the angle desired.
Fanlight openers VENTUS F 200 / VENTUS F 300
Dimensioned drawings, Installation dimensions, G.U security stay EURO-SOLID
Fanlight fittings VENTUS F 200 with electric drive ELTRAL S 230
Stroke 50M
210
76
Closing
M
18
12
193 8
36
32
1
32
26
34
Minimum sash width SW = 620
12
9
Opening
Drive mounted at topOpening stay closed
Opening stay opened
G.U security stay EURO-SOLIDInstallation dimensions VENTUS F 200 Installation dimensions VENTUS F 300
102 Edition 12.2009
Fanlight opener VENTUS F 200
Range of application
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
80
78
76
74
72
70
68
66
64
62
60
58
56
54
52
50
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
40 k
g/m
² (2
x8)
35 k
g/m
² (2x
7)
30 k
g/m
² (2x
6)
25 k
g/m
² (2x
5)
2x8
2x7
2x6
2x5
20 k
g/m
² (2x
4)
1 stay 2 stays 3 stays
Maximum sash width SW
max
.D
im. "
S"
min
.
Fanlight fi ttings VENTUS F 200 with ELTRAL S 230 E / S 230 L
Application range as a function of the centre of mass of the sash
Dim. "S"
Calculation exampleDimension “S”
Application rangeELTRAL S 230 / ELTRAL 300 E1
Weights / heights / widths of sash permitted
VENTUS F 200 with ELTRAL S 230 ELTRAL 300 E1
Max. sash weight 80 kg
Max. weight of glazing [1] 40 kg/m2
Min. Sash height
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
300 mm
300 mm
–
300 mm
Min. Sash width
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
400 mm
620 mm
–
620 mm
Max. Sash width 3600 mm
Space required for drive
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
39 mm
39 mm
–
57 mm
Max. number of stays 3
[1] Depending on Dim. “S” and sash width [2] on side [3] at top
Calculation exampleDimension “S”
Example:
Glazing 2 x 8 mm
Weight of glass 40 kg/m2
Sash width 2200 mm
Dim. “S” 20 – 57 mm possible
Sash weight
max. 80 kg
Weight of glass
max. 40 kg/m2
103Edition 12.2009
14
00
16
00
18
00
20
00
22
00
24
00
26
00
28
00
30
00
32
00
34
00
36
00
100
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
12
00
10
00
80
0
70 k
g/m
2
60 k
g/m
2
50 k
g/m
2 (2x1
0)
40 k
g/m
2 (2
x8)
30 k
g/m
2 (2
x6)
30 kg/m 2 (2x6)
2 stays 3 stays
max
.D
im. "
S"
min
.
Maximum sash width SW
Fanlight fi ttings VENTUS F 300 with ELTRAL S 230 E / S 230 L Fanlight fi ttings VENTUS F 300 with ELTRAL 300 E1
24
00
26
00
28
00
30
00
32
00
34
00
36
00
38
00
40
00
42
00
44
00
46
00
48
00
50
00
52
00
54
00
56
00
58
00
60
00
100
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
22
00
20
00
18
00
120 kg/m2
110 kg/m2
100 kg/m2
90 kg/m2
80 kg/m2
70 kg/m 2
60 kg/m 2
50 kg/m 2
60 kg/m2
Maximum sash width SW
2 stays 3 stays 4 stays 5 stays
max
.D
im. "
S"
min
.
Application range as a function of the centre of mass of the sash
Fanlight opener VENTUS F 300
Range of application
Dim. "S"
Calculation exampleDimension “S”
Example:
Glazing 2 x 10 mm
Weight of glass 50 kg/m2
Sash width 2000 mm
Dim. “S” 25 – 60 mm possible
Sash weight
max. 200 kg
Application rangeELTRAL S 230 / ELTRAL 300 E1
Weights / heights / widths of sash permitted
VENTUS F 300 with ELTRAL S 230 ELTRAL 300 E1
Max. sash weight 200 kg
Max. weight of glazing [1] 70 kg/m2
Min. Sash height
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
468 mm
350 mm
400 mm
350 mm
Min. Sash width
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
620 mm
850 mm
605 mm
850 mm
Max. Sash width 3600 mm 6000 mm
Space required for drive
– Drive mounted vertically [2]
– Drive mounted horizontally [3]
39 mm
39 mm
57 mm
57 mm
Max. number of stays 3 5
[1] Depending on Dim. “S” and sash width [2] on side [3] at top
104 Edition 12.2009
Description VENTUS Mounting PU Order number
Electric drive ELTRAL S 230 E
with electronic control of opening width
Overload cut-offF 200
F 300
Vertical /
horizontal1 6-31732-00-0-*
Electric drive ELTRAL S 230 L
Overload cut-off F 200
F 300
Vertical /
horizontal1 6-31730-00-0-*
Electric drive ELTRAL 300 E1
Cut-off via limit stop switchF 200
F 300Horizontal 1 9-31020-01-0-*
Basic box without lever handle, without sash bracket F 200 Vertical 1 K-15012-00-0-*
Basic box without lever handle, with angular sash bracket F 300 Vertical 1 K-14320-00-0-*
Bag of stay without sash bracket [1] F 200Vertical /
horizontal10 K-15013-00-0-*
Box of stay with angular sash bracket [1] F 300Vertical /
horizontal1 K-13999-00-0-*
Box of angular sash bracket F 200Vertical /
horizontal10 K-15225-00-0-*
Bag of linkage parts
consisting of connecting rod, coupling and guide
for electric drive ELTRAL S 230 E / S 230 L
F 200 Horizontal 1 K-14103-00-0-1
Bag of linkage parts
consisting of connecting rod and coupling
for electric drive ELTRAL 300 E1
F 200 Horizontal 1 K-15216-00-0-1
Bag of linkage parts
consisting of connecting rod, coupling and guide
for electric drive ELTRAL S 230 E / S 230 L
F 300 Horizontal 1 K-14203-00-0-1
Bag of linkage parts
consisting of connecting rod and coupling
for electric drive ELTRAL 300 E1
F 300 Horizontal 1 K-14202-00-0-1
Fanlight openers VENTUS F 200 / VENTUS F 300
Order information – Drives, Fanlight fittings
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016) [1] When a second or more stays are required
105Edition 12.2009
Fanlight openers VENTUS F 200 / VENTUS F 300
Order information – Fanlight fittings, G.U security stay EURO-SOLID
Description VENTUS Mounting PU Order number
Connecting rod ø 8 mm
for electric drive ELTRAL S 230 E / S 230 LF 200 Vertical 1 9-34764-00-0-1
End cap F 200 Horizontal 1 9-34412-00-0-*
Connecting rod ø 12 mm
for electric drive ELTRAL 300 E1F 300 Vertical 1 9-35331-00-0-1
End cap F 300 Horizontal 1 9-34479-00-0-*
Horizontal rod ø 8 mm
– Length 600 mm
– Length 1850 mm
– Length 3300 mm
– Length 6000 mm
F 200Vertical /
horizontal
10
10
10
10
9-25476-06-0-1
9-25476-18-0-1
9-25476-33-0-1
9-25476-60-0-1
Cover profi le
– Length 62 mm
– Length 800 mm
– Length 1800 mm
– Length 3050 mm
– Length 6000 mm
F 200Vertical /
horizontal
10
10
10
10
10
9-33444-01-0-*
9-33444-06-0-*
9-33444-18-0-*
9-33444-33-0-*
9-33444-60-0-*
Horizontal rod ø 10 mm / Cover profi le for horizontal rod
– Length 600 mm
– Length 1870 mm
– Length 3500 mm
F 300Vertical /
horizontal
1
1
1
K-14001-06-0-*
K-14001-18-0-*
K-14001-33-0-*
Alternatively:
Horizontal rod ø 10 mm / Length 6000 mm
Cover profi le / Length 6000 mm
F 300Vertical /
horizontal1
1
9-23055-60-0-1
9-34497-60-0-*
G.U security stay EURO-SOLID
for bottom hung timber/PVC/aluminium windows
– Sash height 270 mm – 350 mm
– Sash height 351 mm – 500 mm
– Sash height 501 mm – 800 mm
– Sash height 801 mm – 1500 mm
F 200
F 300
Vertical /
horizontal
100
100
100
100
6-27995-01-0-1
6-27995-02-0-1
6-27995-03-0-1
6-27995-04-0-1
Bag of profi le-related accessories EURO-SOLID
– for bottom hung timber windows
– Packer for Euro groove 7/8 x 4, 6/8 x 4 / timber
– for bottom hung PVC windows
– for bottom hung aluminium windows
F 200
F 300
Vertical /
horizontal
20
100
K-14681-00-0-1
9-38819-00-0-1
upon request
upon request
* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)
106 Edition 12.2009
Central control units LZ (Ventilation)
Control of 24 V DC drives for the purpose of ventilation.
Central control units LZ enable several ventilation functions and ventilation groups such as, e.g., wind/rain detector, timer switch, building management appliances to be controlled from one central station, thus being an ideal solution for the ventila-tion of individual and/or several rooms.
Technical data
Type LZ 1 LZ 6
Supply voltage 230 V AC ± 10 %, 50 Hz
Output voltage 24 – 28 V DC
Output current 2,5 A 18 A
Max. no. of groups 1 ventilation group6 ventilation groups,
max. 3 A each
Connections
3 terminals for switching contacts with ascending priority, e.g.:1. priority (P1) = superordinate building management system
2. priority (P2) = wind/rain detector3. priority (P3) = ventilation switch for dead man’s and/or locking operating mode
GroupingSeveral central control units LZ 1, also in
combination with central control units LZ 6Several central control units LZ 6, also in
combination with central control units LZ 1
Connection terminals– mains– drive
max. 1,5 mm2
max. 2,5 mm2
max. 1,5 mm2
max. 6,0 mm2
Duty ratio 30 %
IP protection class 54 30
Case PVC Aluminium
DimensionsLZ 1 – Surface-mounted type
160 x 160 x 60 mm W x H x D
LZ 6 – Surface-mounted type
370 x 454 x 110 mm W x H x D
Product overview
107Edition 12.2009
Central control units LZ (Ventilation)
Order information – Central control units and accessories
Description Mounting / Type Order number
Central control unit LZ 1
Surface-mounted 6-35080-00-0-0
Central control unit LZ 6
Surface-mounted 6-35081-00-0-0
Rocker switch “OPEN –STOP – CLOSE”
1-poleSurface-mounted
Flush mounted
6-25539-00-0-0
6-22540-00-0-0
Rocker switch (biased) “OPEN –STOP – CLOSE”
1-poleSurface-mounted
Flush mounted
6-25220-00-0-0
6-25219-00-0-0
Hand-held radio transmitter 42 FH
for electric drives 230 V AC9-42496-00-0-0
Radio actuator FAJ 6 UP
– in combination with radio transmitter 42 FH
– for installation in fl ush box
– 230 V AC, 50 Hz
9-42495-00-0-0
Power supply units 230 V AC / 24 V DC
in surface-mounted plastic case for the connection of 24 V DC
spindle/chain drives and locking actuators
NT 1,25
NT 2,4
NT 5
9-43993-00-0-0
9-43994-00-0-0
9-43995-00-0-0
Power supply units 230 V AC / 24 V DC
Technical data
Description NT 1,25 NT 2,4 NT 5
Mains voltage 230 V AC, 50 Hz
Output voltage 24 V DC
Output current (A) 1,25 2,4 5,0
Apparent output (VA) 30 54 120
Duty ratio 30 %
IP protection class 54
Grouping max. 8 power supply units
Dimensions(W x H x D) (mm) 136 x 180 x 90 120 x 200 x 86 220 x 168 x 106
108 Edition 12.2009
RWA systems
Important advice
Service and maintenance
In order to guarantee the permanent functioning and the value of RWA installations over many years, it is necessary that all technical compo-nents are serviced and tested for safe functioning at regular intervals.
Moreover, it is important to recognise potential danger or missing safety mechanism which might become a source of danger, and to eliminate any risks.
The operator and/or owner is obliged to verify the proper and faultless interaction of all components at least once a year. He must take all necessary measures to protect people using the installations against danger and property against damage.
Regular servicing provides functional safety and diminishes the risk of damage and of liability in the event of a damage. With a service con-tract, the operator’s and/or owner’s fulfi lment of the duty to maintain the installation ready for operation is always documented and proved.
The legal basis for RWA installation servicing is established in direc-tives and regulations which vary from country to country.
The directives and regulations applying in Germany are: “Muster- und Landesbauverordnungen (MBO/LBO)” of the particular states; direc-tive BGR 232 for power-operated windows, doors and shutters (Ger-man employer’s liability insurance association); various directives for safety at work.
As for safety testing, it is necessary to proceed according to the specifi cations of the applicable regulations and standards (e.g., DIN 18650), and to the specifi cations of the manufacturer.
The technician performing the safety checks must be a trained and qualifi ed professional. In general, service and maintenance work may only be carried out by an expert authorised by the manufacturer.
Safe operation and use
With regard to bottom hung sashes, the RAL directives and also the directive BGR 232 for power-operated windows, doors and shutters (German employer’s liability insurance association) prescribe the use of additional catch stays to prevent sashes from uncontrolled falling:
Safety devices such as, e.g., the security stay EURO-SOLID from Gretsch-Unitas must be installed appropriately to ensure their re- liable functioning. The opening width of the catch device must be wide enough to allow for the maximum stroke of the opening motor.
Assembly, installation and initial operation may only be performed by trained experts authorised by the manufacturer.
Motors, central control units and accessories must always be in a faultless technical condition to ensure safe functioning and to pre- vent hazard; they may only be used as intended and in compliance with the particular mounting and operating instructions.
It is necessary that the local regulations and directives should be observed, e.g.:
– Directives for safety at work – Accident prevention regulations – Regulations concerning electrical and electronic engineering (e.g., VDE directives), DIN/EN standards – Directive BGR 232 for power-operated windows, doors and shutters (German employer’s liability insurance association) – Instruction sheet KB.01 of the German association of window and façade manufacturers (VFF) concerning power-operated windows
It is important to always ensure that RWA installations comply with the prevailing regulations. Special attention must be paid to win- dow opening width, permitted installation dimensions, opening speed, pushing force, connecting cable cross section as a function of the cable length, and to current consumption.
The electric drives are designed for use in dry rooms only. They must be protected against dirt and humidity.
Planning and installation
The supply cables must comply with the local fi re protection regulations and feature cross sections which are adequate for the required motor currents.
Manual RWA alarm pushbuttons must be installed at central points where they are clearly visible and freely accessible.
Automatic smoke detectors must be positioned in a way that they can be reached by smoke. Planners and installers must be aware of the space to be covered and provide for a suffi cient number of detectors placed at the right spots.
See also DIN VDE 0833, part 2.
For further information regarding assembly, commissioning and service please refer to our mounting and operating instructions, as well as to the particular installation drawings and wiring diagrams.
109Edition 12.2009
Product overview / Software and Service
Window technology Door technology
Automatic entrance systems Management systems
110 Edition 12.2009
Window technology
Comprehensive product range: Tilt-turn, tilt only, fi rst tilt, and side hung fi ttings, also for round arch head and oblique angle head windows; all available in standard version or in tested / untested security grades
Advantages: – automatic mushroom locking pins – central locking mechanism from standard (basic) secu- rity up to WK 2 – tilt-turn stays with integral slit ventilation
Technical details, fi tting variants
Fitting variants Sash width mm Sash height mm Sash weight kg
Timber or PVCUNI-JET M, UNI-JET SUNI-JET DUNI-JET S-CONTURAUNI-JET S-CONCEALED
280-1600280-1600280-1600400-1400
350-2450350-2450350-2350350-2450
up to 130up to 100up to 130up to 130
AluminiumJET AK 8UNI-JET CUNI-JET D
355-1700280-1600280-1600
500-2400350-2450350-2450
up to 13080 / 130 optional
up to 100
Parallel Slide and Tilt FittingsFittings for parallel slide and tilt units with 2 to 4 sashes.
Technical details, fi tting variants
Fitting variants Sash width mm Sash height mm Sash weight kg
Timber and PVCG.U-966/200 mZG.U-966/150 mZG.U-966/150 oZG.U-90 oZ
720-2000720-1600640-1600640-1600
820-2370820-2370700-2350700-2350
up to 200up to 150up to 130up to 90
AluminiumG.U-968/200 mZG.U-968/150 mZG.U-968/150 oZG.U-90 oZ
740-2000740-1600600-1600600-1600
895-2400895-2400730-2400730-2400
up to 200up to 150up to 130up to 90
All fi ttings with surface sealing ferGUard*silver
Sash components with clip connection
Tilt-Turn Fitting System UNI-JETFittings for single and double sash windows and patio doors made of timber, PVC and aluminium – suitable for manual and automatised hardware assembly in any window fabrication facility.
One handle operation, stays with forced control (mZ)
Up to 200 kg sash weight without additional runner
Designed for sash rebate widths up to 2000 mm (from SRW 1.850 mm with 3rd stay)
Sashes in tilt position secured against being pushed open
Multi-level security concept
Wrong operation safety device
111Edition 12.2009
Window technology
Slide-Fold FittingsFittings for slide-fold units with 3 to 7 sashes.
Lift-Slide Fitting Range, HS-Master and HS-Master CONCEALEDFittings with one handle operation for units with 2 to 6 sashes.
Technical details, fi tting variants
Fitting variants Sash width mm Sash height mm Sash weight kg
Timber and PVCG.U-922G.U-925
400-900400-900
850-2450850-2350
up to 80up to 80
AluminiumG.U-822G.U-825
400-1000400-1000
730-2400730-2400
up to 80up to 80
Technical details, fi tting variants
Fitting variants Sash width mm Sash height mm Sash weight kg
Timber, PVC and aluminiumHS G.U-934HS G.U-937HS-MasterHS-Master CONCEALED
700-3300700-2200
min. SW 950-3300min. SW 1200-3300
850-2765 850-2765up to -2765 1840-2765
up to 300 *up to 150up to 300up to 300
All fi ttings with surface sealing ferGUard*silver
Threshold G.U-thermostep, G.U-threshold 47, G.U-fl atstep, G.U-timberstep
HS-Speed Limiter (mechanical safety component) prevents the sash from accele- rating its movement
Extended application range of lift-locking gear for sash heights up to 2765 mm
Newly engineered runners allow the sliding sashes to run more smoothly and quietly than ever before
Security package for all lift- slide units
HS slit ventilation module – convenient room aeration and enhanced burglar pro- tection (WK2-tested)
HS-Master – operating con- venience due to motor driven lift and slide
HS-Master CONCEALED – operating convenience due to motor driven lift and slide, plus the extra benefi t of so- phisticated design: the drive unit is integrated in the frame profi le
2-wheel runners, bottom running (G.U-922, G.U-822) or top running (G.U-925, G.U-825)
Vertical adjustment as well as sash overlap and gasket pressure adjustment on runners, horizontal adjust- ment on sash hinges
All fi ttings with surface sealing ferGUard*silver
* Special 400 kg / 600 kg variants
112 Edition 12.2009
Window technology
Technical details, fi tting variants
Fitting variants Sash width mm Sash height mm Sash weight kg
Horizontal pivot fi ttings – timberUNITAS 5 Bo, 7 BoUNITAS 10/22°UNITAS 4 (circular window)FERCO 44 EFERCO 45 E
576-2950576-2950
424-2016 Ø576-1450576-1450
700-2200700-2200
700-2000700-2200
up to 175up to 300up to 100up to 80up to 120
Horizontal pivot fi ttings – PVCUNITAS 15, 16 576-2950 * 700-2200 * up to 175
Horizontal pivot fi ttings – aluminiumUNITAS 18 580- * 600- * up to 175
WendebeschlägeUNITAS 93 Bo (timber)UNITAS 88 (aluminium)
782-1600600- *
1250-2350600- *
up to 175up to 175
* max. SW and SH as specifi ed by profi le manufacturers
Horizontal and Vertical Pivot FittingsFittings for horizontal and vertical pivot windows with peripheral gasket:
DUCO VentilatorsFlap ventilators, rotating drum ventilators and sound-absorbing ventilatorsVentilators manufactured from extruded aluminium profi les foradjustable, energy saving and sound reducing ventilation (availableup to sound absorption class 4).
Thermally broken fl ap or rotating drum ventilators with sealing lips or fi nseal brushes
Controlled via lever, rod or cord
Max. length of ventilator: 3000 mm
A hardware system which has proven its value for de- cades; suitable for sash weights up to 300 kg
Vertical pivot fi ttings can be pivoted centrally or eccentri- cally
Technical data of ventilators
DescriptionG.U-DucoFlat DucoPlus
60 GFDucoTon
80 GFDucoMax
Silenzio 200 Uno80 GFO 80 GF 80 BF 100 GFO 100 GF/GFS 100 BF
Application / Features Flap ventilatorsFlap
ventilator
Rotating drum
ventilator
Sound absorbing ventilator
Sound absorbing ventilator
Installation in frame X X X
Installation on frame
Installation in glass rebate X X X X X X X
Installation on masonry X
Glass reduction (mm) 90 80 100 100 60 80 135
Glass thickness (mm) 20,24,28 20,24,28 20,24 20,24,28 20,24,28,32 20,24,28,32 20-42
Installation thickness (mm) 20,24 21
Connection to glazing at bottom X X X X X
Connection to glazing at top X X
Connection to glazing on side X
Airfl ow rate (m³/h) at 2 Pa 56,5 61,6 69,5 50 56,5 - 163,1 35,2
Sound reduction factor (open) Dne,A (dB)
27,3 26,7 27,2 26,1 33 - 45,7 43,1
Sound reduction factor (closed) Dne,A (dB)
44,8 41,7 44,3 31,9 45,8
Installation in the frame or glazing rebate of timber, PVC and aluminium windows
Tightness against driving rain up to 650 Pa
113Edition 12.2009
Window technology
Secure hold of tilt sashes with the opening stay dis-engaged (e.g. for window cleaning) by means of G.U security stay EURO-SOLID
Fan-light OpenersSlimline fan-light opener with face-fi xed stays for tilt (bottom hung inward opening) units with one or more sashes.
Technical details, fi tting variants
Fitting variants Sash width mm Sash height mm Opening width mm
Timber, PVC and aluminiumVENTUS F 200VENTUS F 300
400-3600620-3600
ab 250ab 350
165 / 200220 / 300
Vertical and horizontal rods covered with aluminium profi le
Operation via lever handle, vertical gear or corner gear. Electric drives for individual or group control.
Fittings for rectangular, oblique angle head, arch head and segmental arch head tilt windows, also in enhanced security (“Se”) version
Fittings for top hung outward opening windows
Comprehensive product range consisting of:
Spindle drives, rack and pinion drives, and chain drives
Locking actuators
Opening and locking hard- ware
Compact and modular control centres
Accessories: push buttons, smoke and heat detectors (differential), rain and wind sensors
Advantages of RWA systems:
Enable assisted and unassis- ted rescue in case of a fire emergency
Provide for automatic ventilation
Can easily be fit into window or façade assemblies and in- tegrated in facility manage- ment systems
Smoke and Heat Exhaust (RWA) SystemsWherever utmost reliabilty and fast evacuation of smoke gases are demanded from a smoke exhaust installation in case of fi re, RWA sys-tems provide for safe, automatic opening of smoke exhaust apertures.
114 Edition 12.2009
Window technology / Door technology
Accessories for Builder’s Hardwarefor timber, PVC and aluminium windows and doors.
Our well-assorted accessory range comprises modern high-quality products made from industry-leading manufacturers.
Fixing materials
Glazing tools
Door hinges
Electric door openers
Building chemicals
Composite panels
Gaskets
Window hinges
Insect screens
Multipoint Door LocksMultipoint door lock ranges G.U-SECURY and SECURY-EUROPA for burglary-inhibiting main and secondary entrance doors of timber, PVC or aluminium, and for house and fl at entrance doors with timber and steel frames.
All locking elements throw at least 20 mm and securely engage into strike plates or into a locking rod over the entire height of the door
Panic functions
Backsets from 25 to 90 mm, centres from 70 to 94 mm, spindle from 7 to 10 mm
Available in various forend widths and forend lengths
Safety door locks for burg- lary-inhibiting doors – WK 2 and WK 3 tested, VdS tested to class A
Handle-operated lock types (SECURY-EUROPA) with ma- nual locking; key-operated lock types (G.U-SECURY) with manual, motor-driven or mechanical-automatic locking
All deadbolt and latchbolt variants are secured against being pushed back
115Edition 12.2009
Door technology
Aluminium Floor Thresholds with Thermal Breakfor all house entrance doors and tilt-turn patio doors of timber and PVC, suitable both for new buildings and renovation.Thermally broken thresholds considerably reduce the heat fl ow at the bottom of glazed doors.
Applications:
The threshold programme offers variants for
New buildings and renovation
House entrance and patio doors of timber and PVC
Barrier-free living to DIN 18025
Versatile accessories provi- ding solutions for complicated installation conditions
Threshold-to-frame connec- tors for all current profi les
The importance of thermal break:
With normal interior air conditions (interior temperature + 20 °C, re-lative air humidity 50%), con-densate forms with a surface temperature of approximately + 9.2 °C (dew point temperature).
With normal outside temperatures (down to -10 °C in winter), the effi -cient thermal break of G.U thres-holds achieves a surface tempera-ture clearly higher than + 9,2 °C. The formation of condensate is prevented, the bottom area of the door will not suffer from moisture, a sound building structure will be protected and preserved.
Mortise Locks
Standard locks
DIN standard locks for timber, steel and narrow stile house or fl at entrance doors, and internal doors
Heavy duty locks
For all kinds of project doors – heavy duty locks class 5 are designed for the use on highly frequented doors
Self-locking locks Series 21 for timber and steel doors,Series 19 for narrow stile doors
2 point locking with Automatic latchbolts
Suitability: from standard entrance doors up to so- phisticated escape doors
Electro-clutch (EK) panic locks Series 21 for timber and steel doors, Series 19 for narrow stile doors
Approved for VDS class C
For single and double leaf doors
Multipoint locking for timber and steel doors
Self-locking motor locks Series 19 for narrow stile doors
For single and double leaf doors
Suitable for use in the context of access control and barrier- free construction, or in connection with a swing door drive
116 Edition 12.2009
Door technology
Espace Door Systems to EN 179 and EN 1125
Panic locks and latch plates
For single and double leaf door units
Multipoint safety door locks SECURY Series 21 for timber and steel doors, and SECURY Series 19 for narrow stile doors
3-point locking with three latchbolts
For use on burglary protec- tion doors and escape doors; for single and double leaf units
Self-locking lock Series 21 for timber and steel doors,Series 19 for narrow stile doors
2-point locking with Automatic latchbolts
Suitability: from standard entrance doors up to so- phisticated escape doors
Narrow stile lock Series 18
Approved for standard narrow stile, fi re protection and smoke protection doors
Choice of escape door func- tions for various requirements on single and double leaf narrow stile doors
Panic lock Series 23
For timber and steel doors. For various requirements on single and double leaf fi re protection, smoke protection and escape doors
Push bars, touch bars, door fi ttings
For single and double leaf door units
Locking Cylinders and Master Key Systems
Cylinder Series 50(reversible key system)
Profi le cylinder for single differ, keyed alike locking, registered differ and all suited applications
Cylinder Series 51 SL(reversible key system)
Security cylinder with addi- tional locking members; within master key suites combinable with series 50
Master key system variants
Central locking system for multifamily residences
Master key system for minor offi ce or factory buildings
Grand master key system for large buildings
Cylinder Series 88
Conventional profi le cylinders for single differ and keyed alike applications
Cylinder Series 31
Profi le, round and special type cylinders for all locking applications and types of master key suites
Cylinder Series 33 SL
Security cylinder with addi- tional locking members; within master key suites combinable with series 31
Cylinder Series 45 janus(reversible key system)
Security cylinder for regis- tered differ and complex master key systems
Variable cylinder length (Sandwich design)
117Edition 12.2009
Door technology
Mechatronic Locking System SE– Cost-efficient solutions thanks to the combined use of mechanic,
mechatronic and electronic lockins systems within one master key suite
– One common transponder key for all SE products– Identical, easy programming of all components with one program-
ming device
Electronic cylinder SE
Low-cost integration in master key suites (also retrofitting)
Suitable for escape doors
Twofold security thanks to mechanic and electronic verification of access authorisations
Double cylinder SEwith turn knob
Combination with/retrofitting of all master key suites of Series 31, 33, and also of external master key suites possible
Aesthetic solutions for design-oriented door furnishing (e.g. glass doors)
SE wall reader
Electric gates, elevators, parking barriers and auto- matic doors for barrier-free application can be operated with the SE transponder key, just like the cylinders
KeyManager 3.6
Overall adminstration of mechanic, mechatronic and electronic cylinders and readers
KeyManager 3.6 allows for the direct programming of SE products
One user interface for the display and print of mechanic and electronic access autho- risations
Door Furniture
Security furniture
Complete programme of attractive designs for im- proved security
Tested to EN 1906 – pro- tection classes 1, 2, 3, 4 and standard version
Project furniture to EN 1906
Versatile range of project furniture with choice of handle designs and back- plates in a variety of mate- rials
Furniture for internal doors
In aluminium, stainless steel and brass
Escape door systems to EN 179 and EN 1125
Door handles and push bars for single and double leaf door units
Designer furniture
In stainless steel for sophisti- cated projects
Also for private applications – the backplate can be made to your own design and com- bined with any of our handle models
Push bars and escutcheons
Push bars in a choice of designs
Escutcheons with EN certifi - cation
Security furniture for narrow stile doors
Security furniture with EN 1906 certifi cation
In stainless steel, brass and aluminium
118 Edition 12.2009
Door technology
Overhead Door Closers OTS, Floor Springs UTS, Rebate Door ClosersVersatile range of door closers for single and double leaf doors and hold-open systems.Overhead door closers are suitable for single action swing doors, fl oor springs are suitable for both single and double action swing doors.
Closer types and technical data
Door closer type Linkage Closing force ** for fi re and smoke protection doors **
Overhead door closers OTSOTS 730OTS 630OTS 633/634OTS 530OTS 430, 440/440GOTS 330/210OTS 200/200GOTS 140OTS 80/81
Slide railSlide railSlide rail
Scissor action armScissor action arm/Slide rail
Scissor action armScissor action arm/Slide rail
Scissor action armCrank gear
3 - 62 - 4
3 / 2 - 42 - 6 / 4 - 7
2 - 5 / 22 / 3 / 43 - 4 / 1
1 / 2 / 3 / 42 - 6 / 3 - 5
-
, - / - / ---
- / to DIN 18263, part 1
Rebate door closersRebate door closer 24/20
Concealed installation in the vertical door rebate 2 - 4 / 1 - 2 -
Door closer type Max. load capacity Closing force ** for fi re and smoke protection doors **
Floor springs UTSUTS 85UTS 42UTS 50/60UTS 840 *
300 kg120 kg
120 / 170 kg120 kg
2 - 5 / 3 - 61 - 43 / 4
3 and 4
---
* only for double action swing doors ** Size to EN 1154
Standard /optional features:(depending on closer type and variant)
Integrated door leaf coordina- tion
Mechanical or electro-mecha- nical hold-open device
Interchangeable spindles and spindle extensions
Hold-Open SystemsSmoke and fi re detection accessories for hold-open systems. In the event of a fi re, electrical hold-open devices or holding magnets are disconnected from the mains, thus releasing the door via door closer.
Manual actuation button, surface or flush mounted
Door holding magnets, e.g.: – standard variant with steel base plate – variant with aluminium swivel head – floor-mounted variant
Armature plates
Accessories for hold-open systems:
Smoke control switch unit BMZ 730 H with integral fi re detector
Wall or ceiling-mounted optical smoke detectors
Trigger power supply unit for the voltage supply of smoke switch systems
119Edition 12.2009
Door technology
G.U-BKS ACCESS – Electronic Access ControlTwo system variants to meet particular security requirements:– Stand-alone card system for individual doors– Networked system for complex security zones
Numerous setting functions, e.g. for time zones, access areas, access groups, indi- vidual access, visitor mana- gement, security patrols
Usable in combination with electromechanic locks, escape door systems and automatic door drives, all supplied by the G.U Group
Door release via: – Key pad (PIN code) – Card reader – Biometric fingerprint reader (networked)
Simple operation
Escape door control system FTNT10
Control unit with integral emergency button
Unambiguous signalling
Compatible with many customary wall switch programmes
Approved in accordance with EltVTR
Easy installation, start-up and servicing
G.U-BKS NET interface
Escape Route SecurityCombined with electrically locking panic locks, the FTNT10 escape door control system from G.U-BKS offers effi cient protection against misuse of escpape doors whilst providing unrestricted burglar inhibition.
Electrically locking panic lock EVP
Self-locking locks of Series 21 for timber and steel doors, and Series 19 for narrow stile doors – Latch of electric lock is ideally integrated in the panic lock case (rather than being located at a separate locking point) – Reduced number of system components – Planner and fabricator- friendly lock system
Unlocking Alarm Locking
Controller and exit readerin one unit
Card reader
120 Edition 12.2009
All-glass system solutions
All-Glass System SolutionsWith product design and functionality ideally complementing each other, the Gretsch-Unitas glass hardware range offers new application possibilities of toughened glass assemblies in a building.
A versatile system of door rails and wall connectors allows for the creation of glass partitions with all kinds of door functions
The glass door lock series PRIME Offi ce even provides the possibility to integrate a single glass door or a glass door assembly into a building management system. Electri- cal and electro-mechanical systems with panic functions open up innovative and archi- tecturally attractive solutions with maximal functionality.
Complementing products such as door closers and handles round off the pro- gramme
All-Glass Sliding PartitionsPartition wall systems allow for individual applications in commercial buildings, banks and shop in shop areas in shopping centres.
Manual and fully automatic all-glass sliding partitions
Variable room division
Separation of areas to create representative show rooms
Unlimited creative solutions according to requirements due to linear, curved or seg- mented variants
Convenient opening and closing at the push of a button or manual operation – all at the customer’s option
121Edition 12.2009
Automatic entrance systems
Automatic Entrance SystemsGU Automatic sliding door systems offer functionality, cost-effectiveness and security wherever they are applied. Based on microprocessor-controlled drive units with small installation height, the comprehensive delivery programme provides convenient and barrier-free entrance solutions. Slim frame profi les emphasise the sophisticated door design.All door systems are TÜV-tested (German Technical Supervisory Association) for the use with emergency and escape routes !
Sliding doors
Creation of fi ne entrances with slim drive units
User-friendly opening and closing
Telescopic sliding doors
Large passage areas even in restricted structural openings
Stylish appearance due to slim frame profi les
Curved sliding doors
For entrances with sophisti- cated architecture
Slim drive unit with integral safety sensors
Prismatic sliding doors
Passage convenience com- bined with impressive en- trance design
Available in any angle from 90° to 179°
Swing Door DrivesDrive units for single and double leaf swing doors, suitable for the installation in all locations. Safe and simple operation. Easy retrofi tting of manual doors in the course of renovation. Suitable for the use with fi re and smoke protection doors. A drive variant for infl oor assembly is also part of the programme.
Low-noise operation
Suitable for exterior and interior doors
Easy assembly, start-up and maintenance
Integrated function selection switch with LED indication
Mechanic release from hold-open position
Adjustable wind pressure function
Dynamic adaptation of hold open time
Connection of motor driven lock, SECURY A-opener, electric door opener and safety sensors possible
Slot for radio receiver card
Rugged case in fashionable G.U-BKS design
122 Edition 12.2009
Automatic entrance systems / Management systems
G.U-BKS NETThe management system G.U-BKS NET interconnects our electro-mechanical systems by means of modern bus communication, thus ensuring the automatic interplay of different functions.
Its modern system structure comprises centralised system confi gura-tion as well as centralised system monitoring.
The bus system allows for controlling and visualising a great number of mechatronical products via interface connection to the facility ma-nagement system GEMOS.
Revolving Door SystemsRevolving doors are suitable for a large variety of applications. Meeting individual demands in dimensions and design, they provide functional building entrances with effi cient protection against noise and air draught.
Revolving doors
Operation: manual or with fully automatic drive system
Convenient and safe passage due to 3 or 4-chamber system
Individual creative solutions for sophisticated building architecture
Innovative door design, e.g., all glass assemblies with glass roof and infl oor drive
Security DoorsSecurity revolving doors and security interlocked curved sliding doors for all areas where a high degree of security is required, e.g. in banks, ministries, computer centres.
Controlled admission of authorised persons via integral electronic access control system
Protection of main and side entrances without additional staff
123Edition 12.2009
Management systems
Thanks to its versatility, GEMOS enables the customised, effi cient and convenient implementation of facility-specifi c requirements. Moreover, the Gretsch-Unitas Group of Companies offers all relevant services such as engineering, installation, and, of course, project maintenance. A large number of international references from various application areas attest to the performance ability of this integrative approach.
GEMOS – Security System Solutions for Buildings and FacilitiesThe facility and security management system GEMOS integrates all mechatronic and electronic equipment items of a building, whereby the focus is put on security installations. The web-based management inter-face not only allows to monitor and administer all integrated systems in a truly reliable manner, but also controls the interplay of facility equipment items of different trades.
G.U-BKS NET
Fire detection systems
Intrusion alarm systems
Facility management systems
I/O Modules
Communication systems
Video systems
Access control systems
Reception desk systems
Escape door control systems
Perimeter systems
Emergency alarm systems
UGM
Smoke and heat exhaust vent systems
124 Edition 12.2009
Software and Service
Planning software
Tendering service
Web-based tendering module for the creation of complex specifi -
cations in the formats Word / Excel / Gaeb81 / Gaeb82, with inte-
grated Gaeb import function.
Advantages:
Online with no need for installation
Consistent support for the specifi cation process
Professional creation of BOQs
Single items already composed previously are available as
premade system texts
Permantent upgrade of specifi cation descriptions
Full functionality of the tendering software
Format-consistent data exchange with import/export interfaces
according to the GAEB standard
Service email:
confi GUrator
Product fi nder for determining, quoting, and ordering hardware sets
and parts lists for windows, doors and automatic entrance systems.
Advantages:
Data calculation based on up-to-date prices, conditions and
state of the art
Confi guration of special designs, e.g. oblique angle head win-
dows or round arched windows, taking into account particular
technical restrictions
Confi guration of panic exit devices, fi re doors and multipoint
locked doors to EN 179 and EN 1125 for narrow stile, timber,
and steel door assemblies
Administration of individual quotations and addresses
Service email:
confi [email protected]
KeyManager
Professional software for confi guring, administering, and recording
mechanical and mechatronic master key systems.
Advantages:
Convenient master key system data input with “kwd” fi le
Confi guring and administering master key systems with a single
software
Modern screen display presenting a convenient confi guration
and key combination chart
Service email:
125Edition 12.2009
Software and Service
Ordering software
CIS – Customer Information System
Ordering and customer information system comprising all articles
with specifi ed article number.
Advantages:
Permanent article data upgrade
Illustrated articles
Provision of stock information
Convenient dispatch of orders with import function
(e.g., *.csv fi les)
Service email:
ObS – Order by Scanning
Barcode scanner ordering system for production, store and/or
administration to ascertain material requirements.
Advantages:
Reduced material planning effort
Plausibility check tool eliminates errors
Reduced sourcing times
Service email:
MKS – MasterKeySystem
Web-based tool for planning and ordering master key systems.
Advantages:
Permanent article data upgrade
Plausibility check tool eliminates errors
Maximum availability of information data related to existing
master key systems
Master key system data for BKS KeyManager 3.0 or higher
Free retrieval of key combination records
Service email:
126 Edition 12.2009
Software and Service
Customised solutions
Hardware data service
Creation of individual hardware solutions and provision of CNC data
for automated window fabrication.
Advantages:
Generation of individual hardware data for the market-leading
window fabrication software programmes
Provision of CNC data for the control of production procedures
in window and door fabrication
Up-to-date article data base containing single items and hard-
ware sets
Service email:
Electronic connection to the customer’s merchandise management system
Optimised interfaces allowing for effi cient order processing with the
customer’s material management system.
Advantages:
Complete handling of the digital value-added chain from order
through to invoice
Just-in-time delivery rather than overstocked material stores
Perfected ordering system with the benefi t of error elimination
thanks to the customer’s material management system being
integrated into the ordering procedure around the clock
Service email:
WP00009-04-1-1 – 12/2009 – Printed in Germany
BKS GmbHHeidestr. 71D-42549 VelbertPhone + 49 (0) 20 51 2 01-0Fax + 49 (0) 20 51 2 01-4 31
Gretsch-Unitas GmbHBaubeschlägeJohann-Maus-Str. 3D-71254 DitzingenPhone + 49 (0) 71 56 3 01-0Fax + 49 (0) 71 56 3 01-2 93