Smok & Heat

128
Order Catalogue RWA and ventilation systems Chain drives Spindle drives / Rack and pinion drives Door opening actuator Locking actuators RWA opening systems Fanlight opening systems Control centres Accessories Edition 12.2009

description

Smok & Heat Smok & Heat

Transcript of Smok & Heat

Page 1: Smok & Heat

Order Catalogue

RWA and ventilation systems

Chain drives Spindle drives / Rack and pinion drives

Door opening actuator Locking actuators

RWA opening systems Fanlight opening systems Control centres Accessories

Edition 12.2009

Page 2: Smok & Heat
Page 3: Smok & Heat

3Edition 12.2009

Introduction

RWA systems

Smoke extraction and ventilation installations for staircases . . . . . . . . . 4

Smoke exhaust to EN 12101-2 (SHEV) . . . . . . . . . . . . . . . . . . . . . . . . . . 5

RWA system layout /

Selection criteria for RWA system components . . . . . . . . . . . . . . . . . . . 6

Drives / RWA Opening Systems (24 V DC)

Chain drives ELTRAL K

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Chain drive ELTRAL K20 / K25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 – 15

Chain drive ELTRAL K30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 – 19

Chain drive ELTRAL KS 30/40. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 – 24

Chain drive ELTRAL K60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 – 31

Spindle drives ELTRAL S / Rack and pinion drive ELTRAL Z

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Spindle drive ELTRAL S80 / S160. . . . . . . . . . . . . . . . . . . . . . . . . 33 – 36

Rack and pinion drive ELTRAL Z60. . . . . . . . . . . . . . . . . . . . . . . . 37 – 38

Locking actuators ELTRAL OA / VA

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Square spindle actuator ELTRAL OA . . . . . . . . . . . . . . . . . . . . . . . 40 / 44

Locking actuator ELTRAL VA25. . . . . . . . . . . . . . . . . . . . . . . . . . . 41 / 44

Locking actuator ELTRAL VA35. . . . . . . . . . . . . . . . . . . . . . . . . . . 42 / 44

Locking actuator ELTRAL VA-1 / VA-2. . . . . . . . . . . . . . . . . . . . . . 43 – 46

RWA opening systems

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Opening system RWA 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 – 51

Opening system RWA 1050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 – 56

Fanlight opener VENTUS F 300. . . . . . . . . . . . . . . . . . . . . . . . . . . 57 – 60

Door opening actuator

Door opening actuator TA 60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 – 63

Central control units (24 V DC)

Central control units RZ

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Compact central units RZ 2 and RZ 5. . . . . . . . . . . . . . . . . . . . . . 67 – 69

Modular central units RZ 10/2, RZ 24/4 and RZ 24/8 . . . . . . . . . . 70 – 74

Accessories for RWA installations

Manual alarm buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

Automatic alarm devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Wind/rain detector, wind/rain evaluator . . . . . . . . . . . . . . . . . . . . . . . . 78

Ventilation switches, indicating labels . . . . . . . . . . . . . . . . . . . . . . . . . 79

Timer switch, voltage regulator, test kit, backup batteries . . . . . . . . . . 80

Ventilation Systems (230 V AC)

Chain drives ELTRAL K

Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Chain drive ELTRAL K25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 / 84 / 91

Chain drive ELTRAL KS 30/40. . . . . . . . . . . . . . . . . . . . . . . . . 85 / 86 / 91

Chain drive ELTRAL K30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 / 88 / 92

Chain drive ELTRAL K60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 / 90 / 92

Spindle drive ELTRAL S / Rack and pinion drive ELTRAL Z

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Spindle drive ELTRAL S80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 – 96

Rack and pinion drive ELTRAL Z60. . . . . . . . . . . . . . . . . . . . . . . . 97 – 98

Fanlight opening systems

Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Fanlight openers VENTUS F 200 / VENTUS F 300 . . . . . . . . . . . 100 – 105

Central control units LZ (Ventilation)

Central control units LZ 1 and LZ 6 . . . . . . . . . . . . . . . . . . . . . 106 – 107

Accessories

Rocker switches, biased rocker switches,

hand-held radio transmitter, power supply units. . . . . . . . . . . . . . . . . 107

Important advice

Planning and application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Service and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Product overview of G.U-BKS

Window technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 – 114

Door technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 – 120

Automatic entrance systems . . . . . . . . . . . . . . . . . . . . . . . . . . 121 – 122

Management systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 – 123

Software and Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 – 126

Contents

Page 4: Smok & Heat

4 Edition 12.2009

Basement

Ground floor

First floor

Supply

air

Wind/rain detector

RAUCHABZUG

AUF ZU

RWA pushbutton + ventilation switch

RAUCHABZUG

AUF ZU

RWA control centre

RAUCHABZUG

Smoke/Maximum heat

detector

Smoke/Maximum heat

detector

Smoke/Maximum heat

detector

Exhaust

air

RWA pushbutton + ventilation switch

RWA systems

Smoke extraction and ventilation functions for staircases in one system

An appropriately designed and reliably func-tioning RWA installation

√ saves human lives√ ensures minimum smoke development in escape and rescue routes thus keeping them accessible

√ provides an unobstructed view and facili- tated fi re fi ghting

√ restricts the spread of fi re

Wherever maximum reliability is required of a smoke extracting installation in the event of a fi re and fumes need to be removed quickly, smoke and heat exhaust ventilation systems (RWA) can be used to open smoke outlets automatically and in a safe manner. This pro-tects occupants against smoke poisoning and property against damage. Within the context of everyday ventilation, RWA systems can be used to supply the desired fresh air.

√ protects building, furniture and stored goods against consequential damages

√ reduces fumes and possible subsequent chemical reactions

1

1

2

3

3

3

3

3

RWA system components

1 Drives / Opening systems

Used on roof-lights or façade openings, they ensure automated ventilation and reliable smoke extraction in the event of a fi re, and also provide natural room ventilation and thermal comfort.

2 Control centres

RWA control centres are responsible forsupplying, monitoring and controlling all the connected components as well as for ventilation control. The units fea-ture built-in batteries so that the sys-tems can still respond to a fi re in the event of a power failure for a period of 72 hours.

3 Accessories

Smoke and maximum heat detectors causing automatic alarm release in the event of a fi re, and RWA buttons for ma-nual operation. Ventilation switches are used to control ventilation and deaera-tion functions.

Page 5: Smok & Heat

2

1

4

3

5Edition 12.2009

Smoke exhaust to EN 12101-2 (SHEV)

The Gretsch-Unitas system solution

For smoke extraction in the vertical dimen-sion (façade), the standard EN 12101 – part 2introduced, in September 2006, demands the installation of SHEV systems approved as a whole. It is therefore no longer possible to install an unapproved combination of single components, only SHEV installations are allowed which have been approved as a com- plete system.

Components of a SHEV system

1 Aluminium or timber window profi les

2 Glazing and gaskets

3 Window fi ttings (stays, hinges, etc.)

4 Drive system with associated fastening material

Especially in the fi eld of timber windows, the Gretsch-Unitas Group provides comprehen-sive SHEV system solutions for inward ope-ning window assemblies.

The SHEV system solution offered by the Gretsch-Unitas Group of Companies is based on the standardised Euro groove for alumi-nium profi le systems used by profi le manu-facturers such as, e.g., Alcoa, Alumil, Heroal, Reynaers, Raico and others.

SHEV system solutions approved in accor-dance with EN 12101 – part 2 guarantee a high degree of operational safety in the event of a fi re. Moreover, due to the system provider’s being obliged to clearly specify the components, product selection is made easy.

A G.U SHEV system consists of approved and certifi ed G.U fi ttings (stays, hinges, locking mechanisms) exclusively. All customary ope-ning methods for inward and outward ope-ning windows are possible.

Natural smoke and heat extraction ventilation system (SHEV) in accordance with EN 12101-2

Vorsprung mit System

Securing technology for you

Page 6: Smok & Heat

6 Edition 12.2009

RWA systems

RWA system layout /Selection criteria for system components

RWA Ventilation

External fi re alarm system

RWA pushbutton HSE

Switching contacts for alarm and failure reports

Smoke detector / Maximum heat detector

Facility management

Wind/rain sensor

Ventilation switch

Timer switch /Temperature sensor

Opening systems / Drives

Control centre

System layout

Drives

√ How high is the window to be fi tted with a drive or opening system?

√ Which snow zone is the building located in?√ How large is the fl oor area of the room or staircase to be equipped with a RWA system? Which geometrical or aerodynamically effi - cient opening area is demanded by the building authority? Are there any obstacles such as, e.g., lintels or special profi le thick- nesses to be taken into account?

√ Which type, size and number of window(s) and which opening direction are to be considered when planning the RWA installation?

√ How heavy are the window sashes? Are the drives and fastening elements suited to resist the forces arising on the windows and to achieve the opening widths required?

√ Which mounting method is preferred? (face-fi xed or concealed assembly?)

√ Are the supply and exhaust air openings freely accessible, thus requiring extra safety (burglary preventing) installations?

√ What other infl uences are to be expected?

Control centres

√ Have all openings demanded by the type of building and required according to legal regulations been determined?

√ Have the current consumption values (Ampere) of all drives to be controlled by the RWA centre been summed up?

√ Is it necessary to confi gure ventilation groups? If yes, how many?√ Is automatic triggering through temperature rise or smoke forma- tion useful in addition to the manual release option?

√ Are wind and/or rain sensors to be considered?√ Are alarm or failure reports to be transmitted elsewhere?

Selection criteriaThe questions listed below are intended to make it easy for potential buyers to select the appropriate RWA system components.

Page 7: Smok & Heat

77Edition 12.2009

24 V DC Drives

Chain drives ELTRAL K

Spindle drives ELTRAL S

Rack and pinion drive ELTRAL Z

Locking actuators ELTRAL OA / VA

RWA opening systems

Door opening actuatorTA 60

Page 8: Smok & Heat

8 Edition 12.2009

Chain drives ELTRAL K

Chain drives ELTRAL K20 K25 K30 KS 30/40 [1] K60

Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %

Pushing force (N) 200 250 [2] 300 [2] 300 [2] 600 [2]

Pulling force (N) 200 250 300 300 600

Current consumption (A) 0,5 0,8 0,9 0,9 0,8

Breaking current (A) 0,7 1,0 1,2 1,2 1,2

Opening width (stroke)

(mm) 200/300/400 200/300/400500/600

200/300/400/500 110/200/300/400 250/400/500/600800/1000

IP protection class 32 32 32 30 32

Ambient temperature -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +65 °C -5 °C up to +65 °C -5 °C up to +75 °C

Suitable for roof-lights no no yes no yes

Synchronising control no no yes no yes [3]

Concealed installation acc. to profi le acc. to profi le no no no

DimensionsL x H x D

(mm) 335 x 26 x 41(stroke 200 mm)

335 x 26 x 41(stroke 200 mm)

456 x 43 x 60(all strokes)

386,5 x 38,1 x 58,5(all strokes)

461 x 40 x 56(stroke 250 mm)

Connecting cable Silicone, 3 m, 2-core

Silicone, 3 m,3-core

Silicone; 2 m, 2-core (Solo)

2,5 m, 5-core (Synchro)

2 m, 2-core (Solo)2,5 m, 4-core

(Synchro)

Silicone, 5 m,5-core

Detail informationsee page

9 – 15 9 – 15 16 – 19 20 – 24 25 – 31

With their compact design and pleasant ap-pearance, chain drives are an ideal solution for the fast, electromotor driven opening of exhaust air apertures and for room ventila-tion.

A large variety of mounting brackets allows for assembly in almost every building situ-ation:

– face-fi xed or concealed assembly

– assembly on inward or outward opening top or bottom hung windows, parallel off- set windows, projecting top hung windows, horizontal or vertical pivoting windows, side hung windows, and roof- lights

The intelligent drive technology enables the synchronous control of several chain drives, also in combination with locking actuators.

[1] Due to its plastic case, the ELTRAL KS 30/40 type is not approved for RWA use within the EU.[2] Depending on stroke[3] Up to 500 mm stroke

Product overview

Page 9: Smok & Heat

9Edition 12.2009

145

41

26

12

13

13

Total length L

7

12 6

12

Stroke

Product features SHEV-tested and certified [1]

Compact size

Stainless steel chain

Integral microprocessor controller

Synchronised tandem operation [1]

Electronic limit stop switch

Automatic overload cut-off

Suitable for small sash heights

Total length 200 mm stroke L = 335 mm

300 mm stroke L = 380 mm

400 mm stroke L = 430 mm

500 mm stroke L = 545 mm

600 mm stroke L = 545 mm

Technical data

Chain drive ELTRAL K20 / K25

Product features, Dimensioned drawing, Technical data

Type of drive ELTRAL K20 ELTRAL K25

Nominal voltage 24 V DC

Push/pull force 200 N 250 N [2]

Current consumption 0,5 A 0,8 A

Breaking current 0,7 A 1,0 A

Stroke speed 8 mm/s 8 mm/s (12 mm/s [3])

Duty ratio 30 %

Locking pressure 3000 N

IP protection class 32

Connecting cable Silicone, 3 m, 2-core Silicone, 3 m, 3-core

Case Aluminium EV1 anodised

Dimensioned drawing

Dimensions L x 26 x 41 mm L x H x D

[1] Only ELTRAL K25 [2] Depending on stroke [3] From stroke 500 mm

Page 10: Smok & Heat

10 Edition 12.2009

Chain drive ELTRAL K20 / K25

Application range [1]

350

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

500

250

750

1000

1250

1500

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

K20

ELTRAL K20

350

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

2600

500

425

750

1000

1250

1500

1750

2000

2250

2500

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

K25 VA [2] K25 Synchro VA [2]

K25K25 Synchro

ELTRAL K25

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.[2] VA = Locking actuator (see page 39 et seq.)

Application diagrams

Thrust diagrams

ELTRAL K20 ELTRAL K25

100 200 300 400

100

200

300

0

0

Th

rust

(N

)

Stroke (mm)

100 200 300 400

100

200

300

500 600

0

0

Th

rust

(N

)

Stroke (mm)

Page 11: Smok & Heat

11Edition 12.2009

Chain drive ELTRAL K20 / K25

Order information – Drives

Description Stroke Order number

ELTRAL K20

200 mm

300 mm

400 mm

K-17645-20-0-1

K-17645-30-0-1

K-17645-40-0-1

ELTRAL K25 200 mm

300 mm

400 mm

500 mm

600 mm

K-17646-20-0-1

K-17646-30-0-1

K-17646-40-0-1

K-17646-50-0-1

K-17646-60-0-1

ELTRAL K25

with locking actuator VA25

consisting of 1 chain drive and 1 locking actuator200 mm

300 mm

500 mm

K-17722-20-0-1

K-17722-30-0-1

K-17722-50-0-1

ELTRAL K25 Synchro

consisting of 2 chain drives

200 mm

300 mm

400 mm

500 mm

600 mm

K-17581-20-0-1

K-17581-30-0-1

K-17581-40-0-1

K-17581-50-0-1

K-17581-60-0-1

ELTRAL K25 Synchro

with locking actuator VA25

consisting of 2 chain drives and 1 locking actuator

200 mm

300 mm

500 mm

K-17723-20-0-1

K-17723-30-0-1

K-17723-50-0-1

Note: Mounting sets must be ordered separately.

Page 12: Smok & Heat

12 Edition 12.2009

Description Joinery Order number

Mounting set for fi xing on sash

for bottom hung sash opening inward / top hung sash opening outward

Aluminium [2]

Timber / PVC [3]

K-17595-00-0-8

K-17637-00-0-8

min

. spa

ce r

equi

rem

ent

22

Minimum sash height depending on stroke

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 325* 450* 550* 700* 800*

Mounting set for fi xing on frame

for top or bottom hung sash opening inward

Aluminium [2]

Timber / PVC [3]

K-17594-00-0-8

K-17636-00-0-8

min

. spa

ce r

equi

rem

ent

33

Minimum sash height depending on stroke

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 250*/425 350*/500 550*/600 750* 950*

Chain drive ELTRAL K20 / K25

Order information – Mounting sets for face-fixed assembly

* Pivotable mounted drive, sash weight ≤ 30 kg/m2 [1] Only for bottom hung inward opening sashes (tensile load) [2] With fi xing screws [3] Without fi xing screws

Page 13: Smok & Heat

13Edition 12.2009

Chain drive ELTRAL K20 / K25

Order information – Mounting sets for face-fixed assembly

Description Joinery Order number

Mounting set for direct fi xing on frame

for top or bottom hung sash opening inward

Aluminium [2]

Timber / PVC [3]

K-17593-00-0-8

K-17635-00-0-8

min

. spa

ce r

equi

rem

ent

30

Minimum sash height depending on stroke

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 425 500 600 750 950

Mounting set for fi xing on frame, with base plate

for top hung sash opening outward

Aluminium [1] K-17706-00-0-8

min

. spa

ce r

equi

rem

ent

19

.5

Stroke (mm) 200 300 400

Minimum sash height (mm) 325 450 550

[1] Only for bottom hung inward opening sashes (tensile load) [2] With fi xing screws [3] Without fi xing screws

Page 14: Smok & Heat

14 Edition 12.2009

Chain drive ELTRAL K20 / K25

Order information – Mounting sets for various profile systems – concealed assembly

Description Joinery Order number

Mounting set S

Aluminium K-17874-00-0-0

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 500 650 800 1000 1200

Base plate for mounting set S K-17874-00-0-0

Aluminium K-17875-00-0-0

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 500 650 800 1000 1200

Note: Other profi le systems on request. [1] Only for bottom hung inward opening sashes (tensile load)

Page 15: Smok & Heat

15Edition 12.2009

Chain drive ELTRAL K20 / K25

Order information – Mounting sets for various profile systems – concealed assembly

Description Joinery Order number

Mounting set W / universal aluminium

Aluminium K-17880-00-0-111

.9

15

.9

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 500 650 800 1000 1200

Mounting set / universal timber

Timber K-17909-00-0-1

Stroke (mm) 200 300 400 [1] 500 [1] 600 [1]

Minimum sash height (mm) 500 650 800 1000 1200

Note: Other profi le systems on request. [1] Only for bottom hung inward opening sashes (tensile load)

Page 16: Smok & Heat

456

43

60

228

28

.5

30

16 Edition 12.2009

Chain drive ELTRAL K30

Product features, Dimensioned drawing, Technical data

Product features SHEV-tested and certified

Suitable for customary profiles with Euro groove

Compact size

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Independent of sash overlap dimension

Automatic overload cut-off

Suitable for small sash heights

Variable stroke adjustment

Automatic gasket relief

Technical data

Type of drive ELTRAL K30

Nominal voltage 24 V DC

Push/pull force 300 N

Current consumption 0,9 A

Breaking current 1,2 A

Opening width (adjustable) 200 mm / 300 mm / 400 mm / 500 mm

Stroke speed 12,5 mm/s

Duty ratio 30 %

Locking pressure 2000 N

IP protection class 32

Connecting cable Silicone; 2 m, 2-core (Solo) / 2,5 m, 5-core (Synchro)

Case Zinc die cast

Dimensioned drawing Dimensions 456 x 43 x 60 mm L x H x D

Page 17: Smok & Heat

17Edition 12.2009

Chain drive ELTRAL K30

Application range [1]5

00

60

0

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

16

00

17

00

18

00

19

00

20

00

21

00

22

00

23

00

24

00

25

00

26

00

500

250

750

1000

1250

1500

K30 K30 Synchro

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

Application diagram

Minimum sash height depending on stroke

Stroke (mm) 200 300 400 500

Minimum sash height (mm) 200 300 400 500

Assembly on frame, bottom hung sash opening inward

Stroke (mm) 200 300 400 500

Minimum sash height (mm) 200 400 650 900

Assembly on sash, bottom hung sash opening inward

Stroke (mm) 200 300 400 500

Minimum sash height (mm) 250 350 450 600

Assembly on frame, top hung sash opening outward

Thrust diagram

100 200 300 400 500

100

200

300

400

0

0

Th

rust

(N

)

Stroke (mm)

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.

Page 18: Smok & Heat

18 Edition 12.2009

Chain drive ELTRAL K30

Order information – Drives

Description Stroke Order number

ELTRAL K30 200 mm

300 mm

400 mm

500 mm

K-17832-00-0-*

ELTRAL K30 Synchro

consisting of 2 chain drives 200 mm

300 mm

400 mm

500 mm

K-17833-00-0-*

Note: Mounting sets must be ordered separately. * = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)

Page 19: Smok & Heat

19Edition 12.2009

Description Joinery Order number

Mounting set for fi xing on frame, for bottom hung sash opening inward

without fi xing screws

Aluminium /

Timber / PVCK-17837-00-0-*

min

. spa

ce r

equi

rem

ent

50

Mounting set for fi xing on frame, for projecting top hung window opening outward

without fi xing screws

Aluminium /

Timber / PVCK-17840-00-0-*

Mounting set for fi xing on sash,

for bottom hung sash opening inward / top hung sash opening outward [1]

without fi xing screws

Aluminium /

Timber / PVCK-17841-00-0-*

min

. spa

ce r

equi

rem

ent

37

Mounting set for fi xing on sash,

for bottom hung sash opening inward / top hung sash opening outward [2]

without fi xing screws

Aluminium /

Timber / PVCK-17843-00-0-*

min

. spa

ce r

equi

rem

ent

28

Chain drive ELTRAL K30

Order information – Mounting sets

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016) [1] = Max. overlap 4 mm [2] = Min. overlap 4 mm

Page 20: Smok & Heat

38

.1

386.5

51

min

. 37

28

.5

58

.5

ø46

8.4

ø10

20 Edition 12.2009

Chain drive ELTRAL KS 30/40

Product features, Dimensioned drawing, Technical data

Product features Compact size

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Independent of sash overlap dimension

Automatic overload cut-off

Suitable for small sash heights

Variable stroke adjustment

Automatic gasket relief

Technical data

Type of drive ELTRAL KS 30/40

Nominal voltage 24 V DC

Push/pull force 300 N

Current consumption 0,9 A

Breaking current 1,2 A

Opening width (adjustable) 110 mm / 200 mm / 300 mm / 400 mm

Stroke speed 10 mm/s

Duty ratio 30 %

Locking pressure 1000 N

IP protection class 30

Connecting cable 2 m, 2-core (Solo) / 2,5 m, 4-core (Synchro)

Case PVC

Dimensioned drawing Dimensions 386,5 x 38,1 x 58,5 mm L x H x D

Note:

Due to its plastic case, this drive type

is not approved for RWA use within

the EU.

Page 21: Smok & Heat

21Edition 12.2009

Chain drive ELTRAL KS 30/40

Application range [1]

50

0

40

0

60

0

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

16

00

17

00

18

00

20

00

19

00

21

00

22

00

23

00

24

00

25

00

26

00

500

250

750

1000

1250

1500

KS 30/40 KS 30/40 Synchro

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

Application diagram

Minimum sash height depending on stroke

Stroke (mm) 110 200 300 400

Minimum sash height (mm) 250 600 1100 1500

Assembly on frame, bottom hung sash opening inward

Stroke (mm) 110 200 300 400

Minimum sash height (mm) 200 400 650 900

Assembly on sash, bottom hung sash opening inward

Stroke (mm) 110 200 300 400

Minimum sash height (mm) 150 250 350 450

Assembly on frame, top hung sash opening outward

Thrust diagram

100 200 300 400

100

200

300

400

0

0

Th

rust

(N

)

Stroke (mm)

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.

Page 22: Smok & Heat

22 Edition 12.2009

Chain drive ELTRAL KS 30/40

Order information – Drives

Description Stroke Order number

ELTRAL KS 30/40 110 mm

200 mm

300 mm

400 mm

K-17434-00-0-*

ELTRAL KS 30/40 Synchro

consisting of 2 chain drives 110 mm

200 mm

300 mm

400 mm

K-17436-02-0-*

Note: Mounting sets must be ordered separately. * = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)

Page 23: Smok & Heat

23Edition 12.2009

Chain drive ELTRAL KS 30/40

Order information – Mounting sets

Description Joinery Order number

Mounting set for fi xing on frame, for bottom hung sash opening inward

without fi xing screws

Aluminium /

Timber / PVC

delivered with

the drive

min

. spa

ce r

equi

rem

ent

45

Mounting set for fi xing on sash,

for bottom hung sash opening inward / top hung sash opening outward

without fi xing screws

Aluminium /

Timber / PVC

delivered with

the drive

min

. spa

ce r

equi

rem

ent

28

Chain holder

for bottom hung sash opening inward – fi xing on sash /

for top hung sash opening outward – fi xing on frame

without fi xing screws

Aluminium /

Timber / PVCK-17441-00-0-*

min

. spa

ce r

equi

rem

ent

22

Chain holder

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)

Page 24: Smok & Heat

24 Edition 12.2009

Chain drive ELTRAL KS 30/40

Order information – Mounting sets

Description Joinery Order number

Pivot bearing for bottom hung sash opening inward – fi xing on frame

without fi xing screws

Aluminium /

Timber / PVCK-17440-00-0-*

17

.5

Pivot bearing

Chain holder for projecting top hung window opening outward – fi xing on frame

without fi xing screws

Aluminium /

Timber / PVC9-44272-00-0-*

Chainholder

Metal mounting set

for bottom hung sash opening inward – fi xing on sash

for top hung sash opening outward – fi xing on frame

without fi xing screws

Aluminium /

Timber / PVCK-17720-00-0-*

min

. spa

ce r

equi

rem

ent

22

Metalmounting set

Pivot bearing for roof-lights – fi xing on frame

without fi xing screws

Aluminium /

Timber / PVCK-17735-00-0-*

14

Pivot bearing

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)

Page 25: Smok & Heat

25Edition 12.2009

40

16

230

1819

Total length L56

Product features SHEV-tested and certified

Compact size

Stainless steel chain

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Automatic overload cut-off

Pivotable mountings allow for small sash heights from 350 mm

Emergency release

Total length 250 mm stroke L = 461 mm

400 mm stroke L = 537 mm

500 mm stroke L = 639 mm

600 mm stroke L = 639 mm

800 mm stroke L = 740 mm

1000 mm stroke L = 842 mm

Chain drive ELTRAL K60

Product features, Dimensioned drawing, Technical data

Dimensioned drawing

Dimensions L x 40 x 56 mm L x H x D

Technical data

Type of drive ELTRAL K60 ELTRAL K60 – 300 N

Nominal voltage 24 V DC 24 V DC

Push/pull force 600 N 300 N

Current consumption 0,8 A 0,8 A

Breaking current 1,2 A 1,0 A

Stroke speed 9 mm/s (7,5 mm/s [1]) 13,1 mm/s

Duty ratio 30 %

Locking pressure 3000 N

IP protection class 32

Connecting cable Silicone, 5 m, 5-core

Case Aluminium EV1 anodised

[1] With 250 and 400 mm stroke

Page 26: Smok & Heat

26 Edition 12.2009

Chain drive ELTRAL K60

Application range [1]

50

0

60

0

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

16

00

17

00

18

00

19

00

20

00

21

00

22

00

23

00

24

00

25

00

26

00

500

425

750

1000

1250

1500

1750

2000

2250

2500

K60 VA [2] K60 Synchro VA [2]

K60K60 Synchro

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

Application diagram

Thrust diagram

100 200 300 400 500 600 700 800 900 1000

100

200

300

400

500

600

0

0

Th

rust

(N

)

Stroke (mm)

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.[2] VA = Locking actuator (see page 39 et seq.)

Page 27: Smok & Heat

27Edition 12.2009

Chain drive ELTRAL K60

Order information – Drives

Description Stroke Order number

ELTRAL K60 250 mm

400 mm

500 mm

600 mm

800 mm

1000 mm

K-17648-25-0-1

K-17648-40-0-1

K-17648-50-0-1

K-17648-60-0-1

K-17648-80-0-1

K-17648-01-0-1

ELTRAL K60 Synchro

consisting of 2 chain drives

250 mm

400 mm

500 mm

600 mm

K-17583-25-0-1

K-17583-40-0-1

K-17583-50-0-1

K-17583-60-0-1

ELTRAL K60 – 300 N500 mm

600 mm

K-17882-50-0-1

K-17882-60-0-1

ELTRAL K60 – 300 N Synchro

consisting of 2 chain drives

500 mm

600 mm

K-17883-50-0-1

K-17883-60-0-1

Note: Mounting sets must be ordered separately.

Page 28: Smok & Heat

28 Edition 12.2009

Chain drive ELTRAL K60

Order information – Mounting sets

Description Joinery Order number

Mounting set for fi xing on sash, bottom hung sash opening inward /

Mounting set for fi xing on frame, top hung sash opening outward

Aluminium, short

Timber /

PVC, short

Aluminium, long

Timber /

PVC, long

K-17596-00-0-8

K-17638-00-0-8

K-17598-00-0-8

K-17640-00-0-8min

. spa

ce r

equi

rem

ent

38

min

. spa

ce r

equi

rem

ent

63

Minimum sash height depending on stroke

Stroke (mm) 250 400 500 600 800 [1] 1000 [1]

Min. sash height (mm) / short 450 750 1000 1250 1600 2100

Min. sash height (mm) / long 250 400 550 700 900 1200

Mounting set for fi xing on frame,

for projecting top hung sash opening outward

Aluminium K-17597-00-0-8

min

. spa

ce r

equi

rem

ent

37

Minimum sash height depending on stroke

Stroke (mm) 250 400 500 600

Minimum sash height (mm) 350 900 1100 1400

Mounting set for fi xing on frame,

bottom hung sash opening inward

Aluminium

Timber / PVC

K-17661-00-0-8

K-17662-00-0-8

min

. spa

ce r

equi

rem

ent

48

Minimum sash height depending on stroke

Stroke (mm) 250 400 500 600 800 1000

Minimum sash height (mm) 350 700 1000 1250 1800 2300

Page 29: Smok & Heat

29Edition 12.2009

Chain drive ELTRAL K60

Order information – Mounting sets

Description Joinery Order number

Mounting set for fi xing on sash, bottom hung sash opening inward /

Mounting set for fi xing on frame, top hung sash opening outward

Aluminium

Timber / PVC

K-17659-00-0-1

K-17660-00-0-1

min

. spa

ce r

equi

rem

ent

34

Minimum sash height depending on stroke

Stroke (mm) 250 400 500 600 800 [1] 1000 [1]

Minimum sash height (mm) 350 600 750 900 1100 1400

Mounting set S for fi xing on frame, for roof-lights

Aluminium K-17606-00-0-1

Minimum sash height depending on stroke

Stroke (mm) 250 400 500

Minimum sash height (mm) 350 900 1100

[1] Only for bottom hung inward opening sashes (tensile load)

Page 30: Smok & Heat

30 Edition 12.2009

Chain drive ELTRAL K60

Order information – Mounting sets

Description Joinery Order number

Mounting set RS for fi xing on frame, for roof-lights

Aluminium K-17608-00-0-1

Minimum sash height depending on stroke

Stroke (mm) 250 400 500

Minimum sash height (mm) 350 900 1100

Mounting set W for fi xing on frame, for roof-lights

Aluminium K-17609-00-0-8

Minimum sash height depending on stroke

Stroke (mm) 250 400 500

Minimum sash height (mm) 350 900 1100

Page 31: Smok & Heat

31Edition 12.2009

Chain drive ELTRAL K60

Order information – Accessories

Description Length Order number

Set of base plates [1]

for mounting sets for sash overlap < 10 mm

K-17653-00-0-11

85

70

18

3

70

35

47

.5

5

2 x 2 x 1 x

Cover profi le K60

L = 1450 mm

L = 3000 mm

9-42211-00-0-1

9-42212-00-0-1

Mounting set for cover profi le K60

consisting of: end caps (left / right), 2 spacers, 4 adhesive points, 1 sealing plug

K-17719-00-0-1

[1] For fl ush frame and sash profi les it is necessary to use 2 base plates.

Page 32: Smok & Heat

32 Edition 12.2009

Spindle drives ELTRAL S / Rack and pinion drive ELTRAL Z

Regardless of whether in shopping centres, theatre foyers, airport terminals, or con-servatories – modern spindle or rack and pinion drives on large and heavy roof-lights or façade openings provide fast natural smoke extraction and comfortable auto-matic everyday ventilation.

Spindle and rack and pinion drives are the ideal solution when it comes to opening and closing heavy roof-lights.

Spindle drives and rack and pinion drive ELTRAL

S80 / S80 Synchro S160 Z60

Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %

Pushing force (N) 800 1600 600

Pulling force (N) 800 1600 600

Current consumption (A) 1,0 0,7 1,6

Breaking current (A) 1,4 1,2 2,0

Opening width (stroke) (mm) 300/500/750/1000 300/500/750/1000 180/230/350/550/750/1000

IP protection class 65 65 55

Ambient temperature -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +65 °C

Synchronising control electronic no mechanical

Dimensions L x øDimensions W x H x L

(mm)(mm)

(302 mm + stroke) x 36 (302 mm + stroke) x 3643 x 142 x (135 mm + stroke)

Connecting cable Silicone, 2,5 m, 4-core Silicone, 2,5 m, 4-core 2 m, 2-core

Detail informationsee page

33 – 36 33 – 36 37 – 38

Product overview

Page 33: Smok & Heat

33Edition 12.2009

Extended drive

Returned drive

Ø3

6

19L = 302 + stroke

Stroke

Ø1

8

8

Product features Compact size

Stainless steel thrust tube

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Automatic overload cut-off

Fire tested up to 300 °C

Total length 300 mm stroke L = 602 mm

500 mm stroke L = 802 mm

750 mm stroke L = 1052 mm

1000 mm stroke L = 1302 mm

Technical data

Spindle drive ELTRAL S80 / S160

Product features, Dimensioned drawing, Technical data

Type of drive ELTRAL S80 ELTRAL S160

Nominal voltage 24 V DC

Push/pull force 800 N 1600 N

Current consumption 1,0 A 0,7 A

Breaking current 1,4 A 1,2 A

Stroke speed 10,4 mm/s 7,1 mm/s

Duty ratio 30 %

Locking pressure 12000 N

IP protection class 65

Connecting cable Silicone, 2,5 m, 4-core

Case Aluminium EV1 anodised

Dimensioned drawing

Dimensions (302 + stroke) x 36 mm L x ø

Page 34: Smok & Heat

34 Edition 12.2009

Spindle drive ELTRAL S80 / S160

Order information – Drives

Description Stroke Order number

ELTRAL S80 300 mm

500 mm

750 mm

1000 mm

9-42898-30-0-1

9-42898-50-0-1

9-42898-75-0-1

9-42898-01-0-1

ELTRAL S80 Synchro

consisting of 2 spindle drives with synchronisation control300 mm

500 mm

750 mm

1000 mm

K-17584-30-0-1

K-17584-50-0-1

K-17584-75-0-1

K-17584-01-0-1

ELTRAL S160 300 mm

500 mm

750 mm

1000 mm

9-39075-30-0-1

9-39075-50-0-1

9-39075-75-0-1

9-39075-01-0-1

Note: Mounting sets must be ordered separately.

Page 35: Smok & Heat

35Edition 12.2009

Spindle drive ELTRAL S80 / S160

Order information – Mounting sets

Description Drive Order number

Mounting set S for roof-lights

without fi xing screws

ELTRAL S80

ELTRAL S160

K-17762-00-0-1

K-17767-00-0-1

ELTRAL S80 ELTRAL S160

Mounting set RS for roof-lights

without fi xing screws

ELTRAL S80

ELTRAL S160

K-17764-00-0-1

K-17769-00-0-1

ELTRAL S80 ELTRAL S160

Page 36: Smok & Heat

36 Edition 12.2009

Description Drive Order number

Mounting set W for roof-lights

without fi xing screws

ELTRAL S80 /

ELTRAL S160K-17765-00-0-1

provided by customer

Mounting set for roof-lights / universal

without fi xing screws

ELTRAL S80 /

ELTRAL S160K-17766-00-0-1

30

40

40

46

Spindle drive ELTRAL S80 / S160

Order information – Mounting sets

Page 37: Smok & Heat

37Edition 12.2009

25.517

33.6

32

Ø12

48

135 + stroke

43

54

260

45

97.5

Rack and pinion drive ELTRAL Z60

Product features, Dimensioned drawing, Technical data

Product features Compact size

Galvanised thrust tube

Tandem operation with connecting rod

Electronic limit stop switch

Automatic overload cut-off

Multiple operation with up to 4 drives

Note:

With heavy and large sashes it is possible to operate several drives in a row. A rack and pinion follower can be used as additional opening/locking element (both in single-drive and multiple-drive operating mode). Synchro-nisation between the drives or between drive and follower is effected by means of a mecha-nical connecting rod.

Total length 180 mm stroke L = 315 mm

230 mm stroke L = 365 mm

350 mm stroke L = 485 mm

550 mm stroke L = 685 mm

750 mm stroke L = 785 mm

1000 mm stroke L = 1135 mm

Technical data

Type of drive ELTRAL Z60

Nominal voltage 24 V DC

Push/pull force 600 N

Current consumption 1,6 A

Breaking current 2,0 A

Stroke speed 9,5 mm/s

Duty ratio 30 %

Locking pressure 3000 N

IP protection class 55

Connecting cable 2 m, 2-core

Dimensioned drawing

Dimensions 43 x 142 x (135 + stroke) mm W x H x L

Page 38: Smok & Heat

38 Edition 12.2009

Rack and pinion drive ELTRAL Z60

Order information – Drives

Description Stroke / Length Order number

ELTRAL Z60

180 mm

230 mm

350 mm

550 mm

750 mm

1000 mm

K-17836-18-0-1

K-17836-23-0-1

K-17836-35-0-1

K-17836-55-0-1

K-17836-75-0-1

K-17836-01-0-1

Rack and pinion follower ELTRAL Z60 180 mm

230 mm

350 mm

550 mm

750 mm

1000 mm

K-17844-18-0-1

K-17844-23-0-1

K-17844-35-0-1

K-17844-55-0-1

K-17844-75-0-1

K-17844-01-0-1

Connecting rodL = 1000 mm

L = 1500 mm

L = 2000 mm

L = 2500 mm

9-45469-10-0-1

9-45469-15-0-1

9-45469-20-0-1

9-45469-25-0-1

Ø1

3

Ø1

1

24°

L

Page 39: Smok & Heat

39Edition 12.2009

Locking actuators ELTRAL OA / VA

Suited for use on top or bottom hung windows, projecting top hung windows, parallel offset windows and side hung windows, the locking actuators provide for the motor-driven locking and unlockingof a face-fi xed lock or of the central locking mechanism recessed in the window profi le.

The locking actuators are used in combina-tion with the chain drive types K25 or K60.

Locking actuators ELTRAL OA VA25 VA35VA-1 R/4VA-1 L/4

VA-2/12VA-2/20

Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %

Thrust (N) – 600 600 600 600

Torque (Nm) 10 – – – –

Current consumption (A) 1,1 0,7 0,7 0,8 0,8

Opening stroke(adjustable)

(mm)(°) 90 / 180

17 / 36 18– –

IP protection class 32 32 32 32 32

Ambient temperature -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +75 °C -5 °C up to +75 °C

Synchronising control no no optional optional optional

Concealed installation no yes no no no

Dimensions L x W x H

(mm)156 x 40 x 83,5 473 x 25,2 x 25,2 420 x 35 x 35 420 x 35 x 35

1200 x 35 x 352000 x 35 x 35

Connecting cable Silicone, 2,5 m, 4-core

Silicone, 2,5 m, 2-core

Silicone, 2,5 m, 4-core

Silicone, 2,5 m, 4-core

Silicone, 2,5 m, 4-core

Detail informationsee page

40 / 44 41 / 44 42 / 44 43 – 46 43 – 46

Product overview

Page 40: Smok & Heat

93

.58

3.5

156

7 (square)

46

40

21.521.5

9237.8

40 Edition 12.2009

Square spindle actuator ELTRAL OA

Product features, Dimensioned drawing, Technical data

Product features SHEV-tested and certified

Compact size

Integral microprocessor controller

Electronic limit stop switch and overload cut-off

Integral closing sequence controller

Opening angle adjustable to 90° / 180° via DIP switch [1]

Technical data

Type of drive ELTRAL OA

Nominal voltage 24 V DC

Torque 10 Nm

Current consumption 1,1 A

Opening/closing speed 20°/s

Duty ratio 30 %

Locking force 22 Nm

IP protection class 32

Connecting cable Silicone, 2,5 m, 4-core

Max. switching current 3 A

Dimensioned drawing

Dimensions 156 x 40 x 83,5 mm L x W x H

Note: Depending on the profi le, the spindle must be cut to length by the customer.

Note: Only for use with chain drives ELTRAL K25/K60 (24 V) ! [1] Factory setting is 90°

Page 41: Smok & Heat

30

34

459473

204.5

5.518.5

25.2

41Edition 12.2009

Locking actuator ELTRAL VA25

Product features, Dimensioned drawing, Technical data

Product features SHEV-tested and certified

Compact size

Integral microprocessor controller

Electronic limit stop switch and overload cut-off

Integral closing sequence controller

Stroke adjustable to 17 mm or 36 mm

Emergency release of the central locking mechanism

Switchable running direction

Technical data

Type of drive ELTRAL VA25

Nominal voltage 24 V DC

Nominal force 600 N

Current consumption 0,7 A

Speed 2,8 mm/s

Duty ratio 30 %

Locking pressure 1000 N

IP protection class 32

Connecting cable Silicone, 2,5 m, 2-core

Max. switching current 4,2 A

Dimensioned drawing

Dimensions 473 x 25,2 x 25,2 mm L x W x H

Note: Only for use with chain drives ELTRAL K25/K60 (24 V) !

Page 42: Smok & Heat

42 Edition 12.2009

Locking actuator ELTRAL VA35

Product features, Dimensioned drawing, Technical data

Product features Compact size

Integral microprocessor controller

Electronic limit stop switch and overload cut-off

Integral closing sequence controller

Stroke: 18 mm

Fire tested up to 300 °C

Technical data

Type of drive ELTRAL VA35

Nominal voltage 24 V DC

Nominal force 600 N

Current consumption 0,7 A

Speed 4,2 mm/s

Duty ratio 30 %

Locking pressure 1000 N

IP protection class 32

Connecting cable Silicone, 2,5 m, 4-core

Case Aluminium EV1 anodised

Max. switching current 3 A

Dimensioned drawing

Dimensions 420 x 35 x 35 mm L x W x H

420

Stroke 18 ±1

11

25

364

16

9.5

9.5

35

35

28

26896

12

35

Position 1Position 2

Note: Only for use with chain drives ELTRAL K25/K60 (24 V) !

Page 43: Smok & Heat

111420

35

35

364

16

9.5

31

1030

60

34

17

.5

46

43Edition 12.2009

Locking actuator ELTRAL VA-1 / VA-2

Product features, Dimensioned drawing, Technical data

Product features SHEV-tested and certified

Compact size

Integral microprocessor controller

Electronic limit stop switch and overload cut-off

Integral closing sequence controller

Available with 1 or 2 locking points

Technical data

Type of drive ELTRAL VA-1 / ELTRAL VA-2

Nominal voltage 24 V DC

Nominal force 600 N

Current consumption 0,8 A

Speed 4,2 mm/s

Duty ratio 30 %

Locking pressure 2000 N

IP protection class 32

Connecting cable Silicone, 2,5 m, 4-core

Case Aluminium EV1 anodised

DimensionsELTRAL VA-1 R/4 – VA-1 L/4

420 x 35 x 35 mm L x W x H

ELTRAL VA-2/12

1200 x 35 x 35 mm L x W x H

ELTRAL VA-2/20

2000 x 35 x 35 mm L x W x H

Dimensioned drawing

Drawing shows ELTRAL VA-1 R/4

Note: Only for use with chain drives ELTRAL K25/K60 (24 V) !

Page 44: Smok & Heat

44 Edition 12.2009

Locking actuators ELTRAL OA / VA

Order information – Drives

Description Connection rh/lh /

Length

Order number

ELTRAL OA

9-44712-00-0-1

ELTRAL VA25

K-17724-00-0-8

==

ELTRAL VA35

K-17725-00-0-1

ELTRAL VA-1 R/4, VA-1 L/4

Drive with 1 locking point, face-fi xed

Connection rh

Connection lh

K-17591-42-R-1

K-17591-42-L-1

Drawing shows rh cable connection (lh cable connection = laterally reversed)

ELTRAL VA-2/12, VA-2/20

Drive with 2 locking points

L = 1200 mm

L = 2000 mm

K-17591-12-0-1

K-17591-20-0-1

Page 45: Smok & Heat

45Edition 12.2009

Description Drive Order number

Base plate for mounting on top, bottom, and side hung sashes opening outward

ELTRAL VA-1 R/4

ELTRAL VA-1 L/49-40092-00-0-1

10115.5

10115.5

9.5

9.5

16

50

60

115364

415

5M

5 (

4x)

Ø5

.5 (

4x)

Base plate for mounting on top, bottom, and side hung sashes opening outward

ELTRAL VA-2/12 9-40093-00-0-1

10301

10301

9.5

9.5

16

50

60

5301146

1200

5M

5 (

4x)

Ø5

.5 (

4x)

Base plate for mounting on top, bottom, and side hung sashes opening outward

ELTRAL VA-2/20 9-42197-00-0-1

10301

10301

9.5

9.5

16

50

60

10001946

2000

5M

5 (

5x)

Ø5

.5 (

5x)

Spacer for angular locking bracket – for sash opening outward

from 7 mm overlap

9-42199-00-0-130

20

70

33

616

6.5 Overlap > 7 mm

Spacer

Locking actuator ELTRAL VA-1 / VA-2

Order information – Mounting accessories

Page 46: Smok & Heat

46 Edition 12.2009

Locking actuator ELTRAL VA-1 / VA-2

Order information – Mounting accessories

Description Drive Order number

Spacer for ELTRAL VA-1 R/4, VA-1 L/4

for bottom hung sashes with overlap 12 – 25 mm [1]

415

36425.5

9.5

16

Ø5.5

35

10 Overlap

12 – 25 mm

Spacer

min

. 35

ELTRAL VA-1 R/4

ELTRAL VA-1 L/49-42208-00-0-0

Spacer for ELTRAL VA-2/12

for bottom hung sashes with overlap 12 – 25 mm [1]

ELTRAL VA-2/12 9-42209-00-0-0

1200

114627

9.5

16

Ø5.5

35

10

Spacer for ELTRAL VA-2/20

for bottom hung sashes with overlap 12 – 25 mm [1]

ELTRAL VA-2/20 9-42210-00-0-0

2000

194627

9.5

16

Ø5.5

35

10

700

Sash bracket, small

9-45547-00-0-146

Ø5.5

50

60

10

Ø8

11

.9

[1] Additional spacer required with overlaps exceeding 25 mm.

Page 47: Smok & Heat

47Edition 12.2009

RWA opening systems

Opening system RWA 1000 Automatic opening and closing of top, bottom, and side hung windows opening inward.

Opening system RWA 1050 Automatic opening and closing of side hung windows opening inward.

System components:

• Drive• Mounting set • Electromechanical locking element(s)

Fanlight opener VENTUS F 300 [*]

Effi cient smoke extraction by means of the electro-motor-driven fanlight fi ttings VENTUS F 300 designed for rectangular, vertically installed bottom hung win-dows of timber, PVC or aluminium; electric drives: ELTRAL S 24 L or ELTRAL 300/24.

Opening systems RWA 1000 RWA 1050 VENTUS F 300with ELTRAL S 24 L

VENTUS F 300with ELTRAL 300/24

Operating voltage 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 % 24 V DC ± 15 %

Thrust (N) 1000 600 1200 3000

Duty ratio (%) 30 30 20 20

Current consumption (A) 0,8 0,6 0,7 0,8

Opening width / Stroke (mm) 100 / 200 / 300 100 / 150 / 200 / 250 70 100

IP protection class 54 54 54 54

Synchronising control electronic electronic no no

Dimensions L x W x H (mm) 156 x 40 x 83,5 472 x 25,2 x 25,2 210 x 36 x 76 270 x 55 x 102

Connecting cable Silicone, 2,5 m, 2-core Silicone, 2,5 m, 2-core Silicone, 1,5 m, 4-core Silicone, 1,5 m, 4-core

Detail informationsee page

48 – 51 52 – 56 57 – 60 57 – 60

[*] For further information see our order catalogues “Builder’s Hardware for timber/PVC/aluminium windows and patio doors”

Product overview

Page 48: Smok & Heat

48 Edition 12.2009

Product features Electromechanical sash locking (single or double)

Large opening widths with short strokes even for small-height sashes

Integral closing and opening sequence control

Ventilation control can be integrated as an option

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch and overload cut-off

Max. weight of glazing: 30 kg/m2

Min. space requirement for drive: min. 38 mm

Min. space requirement for mounting bracket: min. 40 mm

Fire tested up to 300 °C

Opening system RWA 1000

Product features, Technical data

Technical data

Opening system RWA 1000

Nominal voltage 24 V DC

Nominal force 1000 N

Current consumption 0,8 A

Breaking current 1,4 A

Speed 2,6 mm/s

Duty ratio 30 %

Locking pressure 12000 N

IP protection class 54

Connecting cable Silicone, 2,5 m, 2-core

Case Aluminium EV1 anodised

Max. switching current 3 A

Page 49: Smok & Heat

49Edition 12.2009

38

150

S100 =

256+stroke

35

Dimensioned drawing

Opening system RWA 1000

Application range, Dimensioned drawing

Opening system Sash height (mm) [1] Opening width (mm) Opening angle (°)

RWA 1000 Stroke 100 mm

550 – 600

600 – 650

650 – 1400

300 – 280

330 – 300

360 – 220

32 – 27

32 – 27

32 – 10

RWA 1000 Stroke 200 mm

700 – 750

750 – 800

800 – 850

850 – 900

900 – 950

950 – 1000

1000 – 1100

1100 – 1200

1200 – 1300

1300 – 1400

1400 – 1500

1500 – 1600

720 – 650

770 – 690

805 – 730

810 – 740

830 – 760

850 – 780

895 – 750

860 – 750

890 – 780

880 – 785

890 – 800

890 – 800

62 – 51

62 – 51

60 – 50

57 – 48

56 – 47

53 – 46

53 – 40

46 – 37

44 – 35

40 – 33

37 – 31

34 – 29

RWA 1000 Stroke 300 mm

1000 – 1100

1100 – 1200

1200 – 1300

1300 – 1400

1400 – 1500

1500 – 1600

1600 – 1700

1700 – 1800

1800 – 1900

1900 – 2000

1050 – 935

1100 – 980

1200 – 1070

1195 – 1075

1190 – 1080

1210 – 1105

1250 – 1140

1285 – 1180

1320 – 1210

1370 – 1260

63 – 50

63 – 48

60 – 48

55 – 45

50 – 42

48 – 40

46 – 39

44 – 38

43 – 37

42 – 37

Maximum sash widths(referring to side of locking actuator)

Sash width [1]

Single locking

– Timber / Aluminium

– PVC – Solo

– PVC – S-Set

430 mm – 1200 mm

400 mm – 800 mm

800 mm – 1200 mm

Double locking (S-Set)

– Timber / Aluminium

– PVC

1200 mm – 2400 mm

1200 mm – 1800 mm

[1] Larger sash dimensions require the use of opening system RWA 1000 S-Set.

Page 50: Smok & Heat

50 Edition 12.2009

Opening system RWA 1000

Order information – Opening systems

Description Stroke Order number

Opening system RWA 1000 Solo [1]

consisting of:

1 locking actuator, 1 spindle drive, mountings

100 mm

200 mm

300 mm

K-17585-10-0-1

K-17585-20-0-1

K-17585-30-0-1

39

38

40 38

A

35

B

111

420

Mou

ntin

g di

men

sion

X

Framebracket

Spindledrive

Locking actuator

Mountingbracket

Locking bracket

Opening system RWA 1000 S-Set (Synchro) [1]

consisting of:

1 locking actuator, 1 control module USKM, 2 spindle drives, mountings

100 mm

200 mm

300 mm

K-17588-10-0-1

K-17588-20-0-1

K-17588-30-0-1

B

Framebracket

Spindledrive

Connecting cable

Mou

ntin

g di

men

sion

X

A

ControlmoduleUSKM

Mountingbracket

Lockingactuator

Lockingbracket

40 38

38 35

111

420

39

[1] 2 hinges must be used on the side(s) where a drive is mounted.

Page 51: Smok & Heat

51Edition 12.2009

Opening system RWA 1000

Order information – Opening systems and replacement parts

Description Stroke / Variant Order number

Opening system RWA 1000 S-Set (Synchro) [1]

consisting of:

1 locking actuator, 1 control module USKM, 2 spindle drives, mountings

100 mm

200 mm

300 mm

K-17587-10-0-1

K-17587-20-0-1

K-17587-30-0-1

39

B

1200

Framebracket

Spindledrive

Connecting cable

Mou

ntin

g di

men

sion

X

A

ControlmoduleUSKM

Locking bracket

Locking bracket

Mountingbracket

38

35

40 38

Lockingactuator

Mounting bracket set for opening system RWA 1000

standard

short

long

9-39105-00-0-1

(delivered with the

system)

9-39104-00-0-1

9-39106-00-0-1

15

0

104120

17

6

40

ø6 (

6x)

5

standard

90

84100

61

740

ø6 (

6x)

5

short

25

0

104120

61

740

ø6 (

6x)

5

long

[1] 2 hinges must be used on the side(s) where a drive is mounted.

Page 52: Smok & Heat

52 Edition 12.2009

Product features Large opening widths up to 85°

Ideally suited for windows providing limited mounting space: the bracket mounted to the frame requires only 22 mm in height

Electronic limit stop switch and overload cut-off

Integral closing and opening sequence control

Ventilation control can be integrated as an option

Integral microprocessor controller

Synchronised tandem operation

Fire tested up to 300 °C

Opening system RWA 1050

Product features, Dimensioned drawing, Range of application, Technical data

Range of application

Minimum sash width / Opening angle

depending on stroke

Stroke (mm) 100 150 200 250

Min. sash width (mm)

(sash dimension B) 510 600 680 740

Opening angle, approx. * 35° 50° 70° 85°

* depending on mounting dimensions

Maximum sash height

Solo (mm) 1500

Synchro (mm) 2000

Dimensioned drawing

Open

ing

angl

e

171

min. 35

Technical data

Opening system RWA 1050

Nominal voltage 24 V DC

Nominal force 600 N

Current consumption 0,6 A

Breaking current 1,2 A

Speed 5,8 mm/s

Duty ratio 30 %

Locking pressure 12000 N

IP protection class 54

Connecting cable Silicone, 2,5 m, 2-core

Case Aluminium EV1 anodised

Max. switching current 3 A

Page 53: Smok & Heat

53Edition 12.2009

Opening system RWA 1050

Order information – Opening systems

Description Stroke Order number

Opening system RWA 1050 Solo

with square spindle actuator and right-hand mounting bracket

consisting of: 1 spindle drive, 1 square spindle actuator, mountings

100 mm

150 mm

200 mm

250 mm

K-17799-10-R-1

K-17799-15-R-1

K-17799-20-R-1

K-17799-25-R-1

max

. 1500

Sash width SW

ELTRAL OAMounting bracket setRWA 1050 right-hand

Opening system RWA 1050 Solo

with square spindle actuator and left-hand mounting bracket

consisting of: 1 spindle drive, 1 square spindle actuator, mountings

100 mm

150 mm

200 mm

250 mm

K-17799-10-L-1

K-17799-15-L-1

K-17799-20-L-1

K-17799-25-L-1

max

. 15

00

Sash width SW

ELTRAL OA

Mounting bracket setRWA 1050 left-hand

Page 54: Smok & Heat

54 Edition 12.2009

Description Stroke Order number

Opening system RWA 1050 S-Set (Synchro)

with square spindle actuator

consisting of:

2 spindle drives, 1 square spindle actuator, 1 control module USKM, mountings

100 mm

150 mm

200 mm

250 mm

K-17800-10-0-1

K-17800-15-0-1

K-17800-20-0-1

K-17800-25-0-1

Syn

chro

max

. 25

00

Sash width SW

ELTRAL OA

Mounting bracket setRWA 1050 right-hand

Mounting bracket setRWA 1050 left-hand

24 V DCmax. 1,6 A

Control moduleUSKM

Opening system RWA 1050 Solo

with right-hand locking actuator VA-1 R/4 and right-hand mounting brackets

consisting of: 1 spindle drive, 1 locking actuator, mountings

100 mm

150 mm

200 mm

250 mm

K-17801-10-R-1

K-17801-15-R-1

K-17801-20-R-1

K-17801-25-R-1

max

. 15

00

Sash width SW

Mounting bracket setRWA 1050 right-handELTRAL VA-1 R/4

Opening system RWA 1050

Order information – Opening systems

Page 55: Smok & Heat

55Edition 12.2009

Opening system RWA 1050

Order information – Opening systems

Description Stroke Order number

Opening system RWA 1050 Solo

with left-hand locking actuator VA-1 L/4 and left-hand mounting bracket

consisting of: 1 spindle drive, 1 locking actuator, mountings

100 mm

150 mm

200 mm

250 mm

K-17801-10-L-1

K-17801-15-L-1

K-17801-20-L-1

K-17801-25-L-1

max

. 15

00

Sash width SW

ELTRAL VA-1 L/4

Mounting bracket setRWA 1050 left-hand

Opening system RWA 1050 S-Set (Synchro)

with locking actuator VA-2/12

consisting of: 2 spindle drives, 1 locking actuator, 1 control module USKM, mountings

100 mm

150 mm

200 mm

250 mm

K-17802-10-0-1

K-17802-15-0-1

K-17802-20-0-1

K-17802-25-0-1

Syn

chro

max

. 25

00

Sash width SW

Mounting bracket setRWA 1050 right-hand

Mounting bracket setRWA 1050 left-hand

24 V DCmax. 1,6 A

Control moduleUSKM

ELTRAL VA-2/12

Page 56: Smok & Heat

56 Edition 12.2009

Opening system RWA 1050

Order information – Opening systems

Description Stroke Order number

Opening system RWA 1050 S-Set (Synchro)

with locking actuator VA-3/20

consisting of:

2 spindle drives, 1 locking actuator, 1 control module USKM, mountings

100 mm

150 mm

200 mm

250 mm

K-17858-10-0-1

K-17858-15-0-1

K-17858-20-0-1

K-17858-25-0-1

Syn

chro

max

. 30

00

Sash width SW

Mounting bracket setRWA 1050 right-hand

Mounting bracket setRWA 1050 left-hand

24 V DCmax. 1,6 A

Control moduleUSKM

ELTRAL VA-3/20

Page 57: Smok & Heat

57Edition 12.2009

Product features Cost-efficient control of several window elements with one drive

Opening widths up to 300 mm, suitable for small sash heights from 350 mm

For sash weights up to 200 kg

Ideally suited for windows offering limited mounting space

High gasket pressure thanks to auto-matically and reliably locked stay arms

Overlap dimension 0 – 25 mm

Opening stay can be released easily for window cleaning

According to sash widths and weights, two drive variants with different motor power are available:

ELTRAL S 24 L / ELTRAL 300/24

Further features:

– Fire tested up to 300 °C

– Simple mounting, horizontal or vertical (rh/lh)

– Adjustable stroke for various opening widths

– Electronic limit stop switch and overload cut-off

Technical data

Fanlight opener VENTUS F 300

Product features, Technical data

Type of drive ELTRAL S 24 L ELTRAL 300/24

Nominal voltage 24 V DC

Nominal force 1200 N 3000 N

Current consumption 0,7 A 0,8 A

Stroke (adjustable) 50 mm / 70 mm [1] 40 – 70 mm [2]

Speed 0,9 mm/s 1,0 mm/s

Duty ratio 20 %

Cutoff Overload cut-off Limit stop switch

IP protection class 54

Connection 4-pole plug 4 x 0,75 mm2, 1,5 m

Dimensions (L x W x H) 210 x 36 x 76 mm 270 x 55 x 102 mm

Case Aluminium

[1] Factory setting = 50 mm stroke = 200 mm opening width (70 mm stroke = 300 mm opening width).[2] Factory setting = 40 mm stroke. When mounted with VENTUS F 300, the stroke must be set to 70 mm (= 300 mm opening width).

Page 58: Smok & Heat

1

41

5

26

5331

29

58 Edition 12.2009

According to the directives of RAL, it is absolutely necessary that

bottom hung sashes must be fitted withcatch stays supple-menting the stan-dard fanlight fittings.

G.U security stays EURO-SOLID prevent damage that might arise from inappropriate attachment of the opening stays. Moreover, they provide great convenience when cleaning the tilted sash by holding it in the angle desired.

Fanlight opener VENTUS F 300

Dimensioned drawings, Installation dimensions, G.U security stay EURO-SOLID

Fanlight fittings VENTUS F 300 with electric drive ELTRAL S 24 L

Stroke 50M

210

76

Closing

15

18

193

36

3 12

32

29

37

89

130

22

Opening

M

Edge of sash up to M = min. 415 (without guide and cover profile = 390)

Minimum sash width SW 850 (without guide = 825)

Drive mounted at topOpening stay closed

Opening stay opened

G.U security stay EURO-SOLIDInstallation dimensions VENTUS F 300

Page 59: Smok & Heat

59Edition 12.2009

14

00

16

00

18

00

20

00

22

00

24

00

26

00

28

00

30

00

32

00

34

00

36

00

100

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

12

00

10

00

80

0

70 k

g/m

2

60 k

g/m

2

50 k

g/m

2 (2x1

0)

40 k

g/m

2 (2

x8)

30 k

g/m

2 (2

x6)

30 kg/m 2 (2x6)

2 stays 3 stays

max

.D

im. "

S"

min

.

Maximum sash width SW

Fanlight fi ttings VENTUS F 300 with ELTRAL S 24 L Fanlight fi ttings VENTUS F 300 with ELTRAL 300/24

24

00

26

00

28

00

30

00

32

00

34

00

36

00

38

00

40

00

42

00

44

00

46

00

48

00

50

00

52

00

54

00

56

00

58

00

60

00

100

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

22

00

20

00

18

00

120 kg/m2

110 kg/m2

100 kg/m2

90 kg/m2

80 kg/m2

70 kg/m 2

60 kg/m 2

50 kg/m 2

60 kg/m2

Maximum sash width SW

2 stays 3 stays 4 stays 5 stays

max

.D

im. "

S"

min

.

Application range VENTUS F 300as a function of the centre of mass of the sash

Fanlight opener VENTUS F 300

Range of application

Dim. "S"

Application rangeELTRAL S 24 L / ELTRAL 300/24

Weights / heights / widths of sash permitted

VENTUS F 300 with ELTRAL S 24 L ELTRAL 300/24

Max. sash weight 200 kg

Max. weight of glazing [1] 70 kg/m2

Min. sash height

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

468 mm

350 mm

400 mm

350 mm

Min. sash width

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

620 mm

850 mm

605 mm

850 mm

Max. sash width 3600 mm 6000 mm

Space required for drive

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

39 mm

39 mm

57 mm

57 mm

Max. number of stays 3 5

Calculation exampleDimension “S”

Example:

Glazing 2 x 10 mm

Weight of glass 50 kg/m2

Sash width 2000 mm

Dim. “S” 25 – 60 mm possible

Sash weight

max. 200 kg

[1] Depending on Dim. “S” and sash width [2] on side [3] at top

Page 60: Smok & Heat

60 Edition 12.2009

Description Mounting PU Order number

Electric drive ELTRAL S 24 L

Overload cut-off Vertical /

horizontal1 6-31734-00-0-*

Electric drive ELTRAL 300/24

Cut-off via limit stop switch

Horizontal 1 9-31021-00-0-*

Basic box without lever handle, with angular sash bracket Vertical 1 K-14320-00-0-*

Box of stay with angular sash bracket [1]Vertical /

horizontal1 K-13999-00-0-*

Bag of linkage parts

consisting of connecting rod, coupling and guide for electric drive ELTRAL S 24 L

Vertical /

horizontal1 K-14203-00-0-1

Bag of linkage parts

consisting of connecting rod, coupling and guide for electric drive ELTRAL 300/24Horizontal 1 K-14202-00-0-1

Connecting rod ø 12 mm

for electric drive ELTRAL 300/24Vertical 1 9-35331-00-0-1

End cap Horizontal 1 9-34479-00-0-*

Horizontal rod ø 10 mm / Cover profi le for horizontal rod

– Length 600 mm

– Length 1870 mm

– Length 3500 mm

Vertical /

horizontal

1

1

1

K-14001-06-0-*

K-14001-18-0-*

K-14001-33-0-*

Alternatively:

Horizontal rod ø 10 mm / Length 6000 mm

Cover profi le / Length 6000 mm

Vertical /

horizontal

1

1

9-23055-60-0-1

9-34497-60-0-*

G.U security stay EURO-SOLID

for bottom hung timber/PVC/aluminium windows

– Sash height 270 mm – 350 mm

– Sash height 351 mm – 500 mm

– Sash height 501 mm – 800 mm

– Sash height 801 mm – 1500 mm

Vertical /

horizontal

100

100

100

100

6-27995-01-0-1

6-27995-02-0-1

6-27995-03-0-1

6-27995-04-0-1

Bag of profi le-related accessories EURO-SOLID

– for bottom hung timber windows

– Packer for Euro groove 7/8 x 4, 6/8 x 4 / timber

– for bottom hung PVC windows

– for bottom hung aluminium windows

Vertical /

horizontal

20

100

K-14681-00-0-1

9-38819-00-0-1

upon request

upon request

Fanlight opener VENTUS F 300

Order information – Drives, Fanlight fittings, G.U security stay EURO-SOLID

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016) [1] When a second or more stays are required

Page 61: Smok & Heat

1693°

408

421

24

16

10

1

40

61Edition 12.2009

Designed to open side hung window sashes and swing doors serving as RWA supply air opening:

The door drive TA 60 ensures the supply of air required for smoke extraction in the event of a fi re. A thermal lift is produced causing the smoke gases to rise and es-cape quickly.

In combination with an electric door ope-ner it is possible to use the door drive for unimpeded, convenient access.

Suitable for use on 2-leaf doors and panic doors.

Product features Compact size

Integral microprocessor controller

Potential-free contact

Electronic limit stop switch

Automatic overload cut-off

For door leaf widths from 450 mm

Direct mounting possible

For opening angles up to 93°

Delayed opening

Technical data

Door opening actuator ELTRAL TA 60

Product features, Dimensioned drawing, Technical data

Type of drive ELTRAL TA 60

Nominal voltage 24 V DC

Push/pull force 200 N / 600 N

Opening/closing speed 3°/s

Current consumption 1,4 A

Duty ratio 30 %

Opening torque (continuous / maximum) 180 Nm / 216 Nm

Closing torque 72 Nm

IP protection class 32

Potential-free contact max. 50 V; 0,5 A

Connecting cable Silicone, 5 m, 5-core

Case Aluminium EV1 anodised

Max. switching current 3 A

Dimensions 421 x 40 x 101 mm L x W x H

Page 62: Smok & Heat

62 Edition 12.2009

Door opening actuator ELTRAL TA 60

Order information – Drives

Description Order number

ELTRAL TA 60

6-33971-00-0-1

ELTRAL TA 60 – S-Set for 2-leaf doors

consisting of 2 door drive units

with 2 different opening delays: active leaf with 5 s, passive leaf with 7 s delay

K-17860-00-0-0

Note:

The reliable everyday operation and secure locking of a door requires the installation of a multipoint lock with

electric opener such as, e.g., G.U-SECURY Automatic with A-opener [1]. The complete door assembly is actuated

via central control unit.

[1] For the comoplete range of multipoint locks and electric door openers please refer to our order catalogue “Safety Door Locks, Aluminium Thresholds and Door Closers”.

Page 63: Smok & Heat

63Edition 12.2009

Door opening actuator ELTRAL TA 60

Order information – Mounting sets

Description Order number

Mounting bracket set for mounting on frame [1]

consisting of 3 angular brackets (one for drive-to-frame connection, two ones for stay-to-leaf connection)

K-17328-00-0-1

90°

100

40

50

50

50

75

105,5

max. 117min. 78

Mounting bracket for mounting to side opposite to hinges [2]

without fi xing screws

9-45614-00-0-1

24

100

50

7 11

33

61.5

85.5

[1] 2-leaf door assemblies require 2 sets. [2] 2 brackets required for each drive.

Page 64: Smok & Heat

64 Edition 12.2009

Page 65: Smok & Heat

6565Edition 12.2009

Control centres

Compact control centres RZ 2, RZ 5

Modular control centresRZ 10/2, RZ 24/4, RZ 24/8

Control centre extensions

Page 66: Smok & Heat

66 Edition 12.2009

Central control units RZ (RWA)

The basic benefi ts of central control units RZ are:

Usability for both smoke exhaust and everyday ventilation

Integral backup batteries guaranteeing 72 hours operation in the event of a power failure

Electronic monitoring of cables leading to drives and detectors.

Extension of alarm and ventilation lines if required

Optional alarm forwarding to central building control system via potential-free contacts

Optional extensions such as, e.g., wind and rain detectors

Compact control centres Modular control centres

Centre RZ 2 RZ 5 RZ 10/2 RZ 24/4 RZ 24/8

Power output (A) 2 5 10 24 24

DimensionsW x H x D

(mm)350 x 250 x 120 350 x 250 x 120 500 x 500 x 200 600 x 600 x 250 800 x 800 x 250

Design compact compact modular modular modular

Max. no. of RWA groups 1 1 up to 2 up to 4 up to 8

Max. no. of ventilation groups 1 1 up to 2 up to 4 up to 8

Potential-free contacts for the transmission of alarm and

failure reports

optional optional standard standard standard

Signal input for external alarm

optional standard optional optional optional

Signal input for wind/rain detector

optional standard optional optional optional

Automatic ventilation „CLOSE“ optional standard optional optional optional

Linking of multiple control centres

– – optional optional optional

Backup batteries included included included optional(2 x 12 V)

optional(2 x 12 V)

Detail informationsee page

67 – 69 67 – 69 70 – 74 70 – 74 70 – 74

RWA control centres are available as com-pact or as extendable modular units. They are used wherever highest reliability and rapid extraction of smoke gases are needed.

RWA control centres are responsible for supplying, monitoring and controlling all the connected components (e.g., automatic de-tectors, manual alarms, electric drives) as well as for ventilation control.

Providing for the prompt actuation of smoke extraction openings to allow toxic gases to escape in the event of a fi re, RWA control centres constitute a primary element of preventive fi re protection.

Product overview

Page 67: Smok & Heat

67Edition 12.2009

Product features Compact sheet-steel case, lockable

Integral microprocessor controller

Emergency power supply min. 72 hours

Failure indication

Line monitoring

Alarm monitoring

Integral runtime limitation [1]

Extension slots for

– wind and rain detector [2] [3]

– automatic closing in ventilation mode [2] [3]

– relay card to forward the potential-free signals “EMERGENCY-OPEN” and “Failure”

Adjustable charging voltage

Technical data

Compact central units RZ 2 and RZ 5

Product features, Technical data

Type RZ 2 RZ 5

Nominal voltage 24 V DC

Supply voltage 230 V AC, 50 Hz

Power output 2 A 5 A

Apparent output 48 VA 120 VA

Ambient temperature -5 °C up to +40 °C

Emergency power supply min. 72 hours

Backup batteries 2 Ah

Max. no. of groups 1 ventilation group / 1 RWA group

IP protection class 20

Case surface mounted: sheet-steel, white (RAL 1013) / fl ush mounted: sheet-steel, white (RAL 9010)

DimensionsSurface-mounted type

350 x 250 x 120 mm W x H x D

Flush-mounted type

330 x 445 x 90 mm W x H x D

[1] Only with type RZ 5 (with type RZ 2 as an option) [2] Only with type RZ 2 (with type RZ 5 as a standard) [3] Slot either for wind/rain detector or for automatic closing in ventilation mode

Page 68: Smok & Heat

68 Edition 12.2009

Compact central units RZ 2 and RZ 5

Order information – Control centres

Description Type Order number

RZ 2

Surface-mounted

Flush-mounted

6-30771-00-0-0

9-42151-00-0-0

Standard– Backup batteries

– Failure indication

Optional

– Potential-free contacts to forward alarm and failure signals

– Signal input for external alarm

– Wind/rain card (WR 71)

– “Automatic close” card (ZA 71)

RZ 5

Surface-mounted

Flush-mounted

9-41996-00-0-0

9-42070-00-0-0

Standard

– Backup batteries

– Failure indication

– Signal input for external alarm

– Wind/rain card

– “Automatic close” card

– Ventilation control

Optional – Potential-free contacts to forward alarm and failure signals

Page 69: Smok & Heat

69Edition 12.2009

Compact central units RZ 2 and RZ 5

Order information – Control centre extensions and accessories

Description Type Order number

Wind / rain card WR 71

RZ 2 9-42080-00-0-0

Specifi cation:

– Switching threshold adjustable to various wind speeds

– Switching status indication (wind/rain)

– Operating status controllable externally via potential-free contacts

Relay card REL 65

RZ 2 / RZ 5 9-42000-00-0-0for “EMERGENCY OPEN” and “Failure” signal transmission

– Potential-free contact (max. 48 V / 1 A)

– Slot for “Failure” and “EMERGENCY OPEN”

“Automatic close” card ZA 71

RZ 2 9-42072-00-0-0

Specifi cation:

– Adjustable closing time

– Operating status indication

– Checkbutton to show or change settings

Runtime module LZM

RZ 2 9-42074-00-0-0for the electronic stroke limitation of ventilation drives

– Setting range 5 – 999 s

End of line module 70 MRZ 2 / RZ 5 9-42071-00-0-0

to close off the last line or drive terminal jack

Maintenance card

RZ 2 / RZ 5 9-42001-00-0-0for the indication of the annually required servicing

(at 15 months’ intervals)

Relay for function transmissionRZ 2 / RZ 5 9-42090-00-0-0

for the control of external devices (max. 230 V / 10 A)

Connecting module – Ventilation

RZ 2 / RZ 5 9-42077-00-0-0

for the conversion of continuous signals into short-time pulses

Application:

– Room temperature sensor / hygrostat / conservatory controller / time switch

– For the reception of building management system signals

Replacement key RZ 2 / RZ 5 9-45747-00-0-0

Page 70: Smok & Heat

70 Edition 12.2009

Product features Compact sheet-steel case, lockable

Integral microprocessor controller

Emergency power supply min. 72 hours

Failure indication

Line monitoring

Alarm monitoring

Extension slots for

– wind and rain detector– automatic closing in ventilation mode– relay card to forward the potential- free signals “EMERGENCY-OPEN” and “Failure”

Linking of multiple control centres

Extension of alarm and ventilation lines if required

Integral runtime limitation

Variable RWA and ventilation group arrangements

Technical data

Modular central units RZ 10/2, RZ 24/4 and RZ 24/8

Product features, Technical data

Type RZ 10 RZ 24/4, RZ 24/8

Nominal voltage 24 V DC

Supply voltage 230 V AC, 50 – 60 Hz

Output 10 A 24 A

Apparent output 250 VA 580 VA

Emergency power supply min. 72 Stunden

Backup batteries 24 Ah 38 Ah

Max. no. of groups 2 ventilation groups / 2 RWA groupsRZ 24/4: 4 ventilation groups / 4 RWA groupsRZ 24/8: 8 ventilation groups / 8 RWA groups

IP protection class 54

Ambient temperature -5 °C up to +40 °C

Case Sheet-steel, gravel grey (RAL 7032)

DimensionsRZ 10/2 – Surface-mounted type

500 x 500 x 200 mm W x H x D

RZ 24/4 – Surface-mounted type

600 x 600 x 250 mm W x H x D

RZ 24/8 – Surface-mounted type

800 x 800 x 250 mm W x H x D

Page 71: Smok & Heat

71Edition 12.2009

Modular central units RZ 10/2, RZ 24/4 and RZ 24/8

Order information – Control centres

Description Type Order number

RZ 10/2 [1]

Surface-mounted 9-44730-00-0-0Standard

– Backup batteries

– Motherboard GP 70, 10 A, 2 free slots

– Connection terminals

– Device fuses

– Potential-free contacts to forward alarm and failure signals

– Control card STK 70 with indication of power supply failure,

line feed failure, collective faults and collective triggering

Optional see “Order information – Control centre extensions”

RZ 24/4 [1]

Surface-mounted 6-34565-00-0-0

Standard

– Motherboard GP 70, 24 A, 4 free slots

– Connection terminals

– Device fuses

– Potential-free contacts to forward alarm and failure signals

– Control card STK 70 with indication of power supply failure,

line feed failure, collective faults and collective triggering

Optional see “Order information – Control centre extensions”

Important: The batteries (12 V, 24 Ah, order number 9-40287-00-0-0) must be ordered separately; see “Order information – RWA accessories”.

RZ 24/8 [1]

Surface-mounted 9-44711-00-0-0

Standard

– Motherboard GP 70, 24 A, 8 free slots

– Connection terminals

– Device fuses

– Potential-free contacts to forward alarm and failure signals

– Control card STK 70 with indication of power supply failure,

line feed failure, collective faults and collective triggering

Optional see “Order information – Control centre extensions”

Important: The batteries (12 V, 38 Ah, order number 9-40288-00-0-0) must be ordered separately; see “Order information – RWA accessories”.

[1] For the fulfi lment of the basic functions it is necessary to install group card RWA 70 or RWA 70 V on the motherboard. For ordering the group cards see “Order information – Control centre extensions and accessories”.

Page 72: Smok & Heat

72 Edition 12.2009

Modular central units RZ 48/4, RZ 48/8 and RZ 72/8

Order information – Control centres with increased power output

Description Type Order number

RZ 48/4 [1]

Surface-mounted 6-35077-00-0-0Power output 48 A

Max. no. of groups 4 ventilation groups / 4 RWA groups

RZ 48/8 [1]

Surface-mounted 6-35078-00-0-0Power output 48 A

Max. no. of groups 8 ventilation groups / 8 RWA groups

RZ 72/8 [1]

Surface-mounted 6-35079-00-0-0Power output 72 A

Max. no. of groups 8 ventilation groups / 8 RWA groups

[1] Further product features same as those of modular central unit RZ 24

Page 73: Smok & Heat

73Edition 12.2009

Modular central units RZ 10/2, RZ 24/4 and RZ 24/8

Order information – Control centre extensions and accessories

Description Type Order number

Group card RWA 70 (current consumption max. 6 A) [1]

RZ 10 / RZ 24 9-39951-00-0-0

Specifi cation:

– 2 separate – closed current controlled – alarm lines for max. 10 detectors, each

– Programmable failure and triggering indication

– 1 closed current controlled drive line with separate failure indication

– 1 ventilation line for max. 10 ventilation switches with the corresponding indications

– Selection between locking and dead man’s operating mode

– External signals (from building management or fi re alarm system) can be processed

on alarm line B

– “EMERGENCY OPEN” function in case of drive line failure

– Reclocking (regeneration) of signal pulses for at least 15 smoke extraction opening

cycles within 30 minutes

– End of line module 70 M to close off the last line or drive terminal jack

Group card RWA 70 V (current consumption max. 10 A) [1]

RZ 10 / RZ 24 9-42082-00-0-0Specifi cation:

– same as group card RWA 70 – 9-39951-00-0-0

Ventilation card LE 70 (current consumption max. 6 A)

RZ 10 / RZ 24 9-39952-00-0-0

Specifi cation:

– 1 ventilation line for max. 10 ventilation switches

– Selection between locking and dead man’s operating mode

– Potential-free contacts for external triggering (e.g. building management system)

– Connection of external “Ventilation OPEN / CLOSED” indications

– End of line module 70 M to close off the last line or drive terminal jack

Ventilation card LE 70 V (current consumption max. 10 A)

RZ 10 / RZ 24 9-39953-00-0-0Specifi cation:

– same as ventilation card LE 70 – 9-39952-00-0-0

Wind / rain card WR 70 N

RZ 10 / RZ 24 9-45301-00-0-0

Specifi cation:

– Switching threshold adjustable to various wind speeds

– Switching status indication (wind/rain)

– Operating status controllable externally via potential-free contacts

Master-slave card MS-PE 70 [2] [3]

RZ 10 / RZ 24 9-42118-00-0-0

Specifi cation:

– 2 group cards (RWA 70 or RWA 70 V) or different control centres can be combined

to one group

– Signal transmission “EMERGENCY OPEN” to subordinate central units

– Indication of slave control unit failures

[1] Important: It is not permitted to use different types of group cards in one central unit.[2] Only required for the master central unit. [3] When using the Master-Slave card MS-PE 70, a group card RWA 70 or RWA 70 V is required for each central unit connected.

Page 74: Smok & Heat

74 Edition 12.2009

Modular central units RZ 10/2, RZ 24/4 and RZ 24/8

Order information – Control centre extensions and accessories

Description Type Order number

Motherboard extension GPE 70RZ 24 9-42265-00-0-0

Motherboard GP 70 slot extension

Relay card REL 65

RZ 10 / RZ 24 9-42000-00-0-0for “EMERGENCY OPEN” and “Failure” signal transmission

– Potential-free contact (max. 48 V / 1 A)

– Slot for “Failure” and “EMERGENCY OPEN”

Runtime module LZM

RZ 10 / RZ 24 9-42074-00-0-0for the electronic stroke limitation of ventilation drives

– Setting range 5 – 999 s

End of line module 70 MRZ 10 / RZ 24 9-42071-00-0-0

to close off the last line or drive terminal jack

Maintenance card

RZ 10 / RZ 24 9-42001-00-0-0for the indication of the annually required servicing

(at 15 months’ intervals)

Relay for function transmissionRZ 10 / RZ 24 9-42090-00-0-0

for the control of external devices (max. 230 V / 10 A)

Handover module

RZ 10 / RZ 24 9-42087-00-0-0for transmitting signals to a building management system

– with 3 disconnect terminals

Takeover module

RZ 10 / RZ 24 9-42088-00-0-0for receiving signals and transmitting them to the control centre

– with 2 disconnect terminals

Connecting module – Ventilation

RZ 10 / RZ 24 9-42077-00-0-0

for the conversion of continuous signals into short-time pulses

Application:

– Room temperature sensor / hygrostat / conservatory controller / time switch

– For the reception of building management system signals

Connecting module – Smoke switch control centre

RZ 10 / RZ 24 9-40077-00-0-0for connecting external normally-open contacts to alarm line B

– Monitoring of the closed-circuit current of the control centre

Replacement key RZ 10 / RZ 24 9-45748-00-0-0

Page 75: Smok & Heat

75Edition 12.2009

Accessories for RWA installations

Manual alarm devices Automatic alarm devices Wind and rain detector Ventilation switches Indicating labels

Page 76: Smok & Heat

76 Edition 12.2009

Accessories for RWA installations

Order information – Manual alarm devices

Description Finish Order number

RWA pushbutton HSE

Primary RWA pushbutton for manual triggering of an RWA alarm

signal and signal transmission to the RWA control centre

Product features:

– Buttons “EMERGENCY-OPEN” and “CLOSE”

– Indications: “EMERGENCY-OPEN”, operating status and failure

– Dimensions: 130 x 130 x 32 mm (W x H x D)

red

grey

yellow

blue

orange

9-41997-00-0-9

9-41997-00-0-1

9-41997-00-0-3

9-41997-00-0-0

9-41997-00-0-9

RWA pushbutton HSE-N

Secondary RWA pushbotton for manual triggering of an RWA alarm

signal and signal transmission to the RWA control centre

Product features:

– Button: “EMERGENCY-OPEN”

– Indication: “EMERGENCY-OPEN”

– Dimensions: 130 x 130 x 32 mm (W x H x D)

red

grey

yellow

blue

orange

9-41998-00-0-9

9-41998-00-0-1

9-41998-00-0-3

9-41998-00-0-0

9-41998-00-0-9

Replacement key for RWA pushbutton HSE 9-45611-00-0-6

Frame for in-wall mounting of RWA pushbutton HSE

– Wall recess dimensions: 140 x 140 x 30 mm

– Outer dimensions of frame: 171 x 171 x 26 mm light grey

(RAL 7035)9-42236-00-0-0

Replacement glass for RWA pushbutton HSE 9-42235-00-0-0

Adhesive label indicating “Smoke Vent”

for RWA pushbutton HSE9-42233-00-0-0

Page 77: Smok & Heat

77Edition 12.2009

Accessories for RWA installations

Order information – Automatic alarm devices

Description Order number

Optical smoke switch SSD 521 [1]

Product features:

– Voltage range: 18 – 30 V DC

– Current consumption: 0,1 mA

– With mounting socket

– Visual alarm indication

– Dimensions: ø 120 mm x 80 mm

– IP protection class: 44

– Colour: electro white

6-32355-00-0-0

Maximum heat detector [2]

Product features:

– Voltage range: 18 – 30 V DC

– Current consumption: 0,15 mA

– With mounting socket

– Visual alarm indication

– Dimensions: ø 120 mm x 80 mm

– IP protection class: 44

– Colour: electro white

6-32356-00-0-0

Protection against thrown balls

(for smoke detector SSD 521 and maximum heat detector)9-42264-00-0-0

[1] Only for dust-free spaces.[2] Only for dry spaces. Connection to alarm line only !

Page 78: Smok & Heat

78 Edition 12.2009

Accessories for RWA installations

Order information – Wind/rain detector, wind/rain evaluator

Description Order number

Rain detector 24 V AC/DC

consisting of:

– Sensor

– Operation indicator LED

– Integral heater

– 4 m connection cable, output approx. 150 mA

Functional mode:

When rain or snow starts falling, the sensor transmits a “closing” signal to a building

management system or to a RWA/Ventilation control centre. The heated sensor surface

(heater with a 5 minutes’ switch-on delay) ensures reliable functioning.

9-39062-00-0-0

Wind and rain detector

consisting of:

– Wind sensor

– Rain sensor 24 V AC/DC

– Bracket for pole or wall mounting

– Clamping ring

Functional mode:

With wind speeds < 1 m/s, all RWA supply air openings are opened (leeward side of buil-

ding); with wind speeds > 1 m/s, they are closed (windward side of building). The control

of the wind and rain detector is based on arithmetically averaged values measured over a

period of 10 minutes.

K-15331-00-0-0

Wind/rain evaluator WRAG 2

– Allows for the connection of wind/rain detectors to several control centres

– Supply voltage: 230 V AC, 50 Hz, 5 A

– Separate connection of a normally-open contact possible (e.g. ventilation switch,

timer switch)

– Switch-on delay with wind and rain, and switch-off delay with wind, to prevent constant

on/off switching

– 4 adjustable DIP switches for signal transmission via relay outputs (2 x 1 Um)

– Direct connection of drives (max. total current consumption 5 A)

– Switching threshold adjustable to wind speeds from 2.5 to 20 m/s

– LEDs indicating wind, rain, operating status

– Surface-mount case for top hat rail 35 mm

– Case dimensions (W x H x D): 105 x 86 x 58 mm

9-42268-00-0-0

Relais for wind/rain evaluator WRAG 2

for multiple contacts

2 contacts with 8 A maximum contact load

9-42269-00-0-0

Page 79: Smok & Heat

79Edition 12.2009

Accessories for RWA installations

Order information – Ventilation switches and indicating labels

Description Order number

Ventilation switch “OPEN – CLOSE” – surface-mounted

Case dimensions: 80 x 80 x 44 mm (W x H x D)

Colour: pearl white RAL 10136-24372-00-0-0

Ventilation switch “OPEN – CLOSE” – fl ush mounted

(for ø 60 mm standard fl ush box)

Case dimensions: 80 x 80 x 35 mm (W x H x D)6-24373-00-0-0

Ventilation key switch “OPEN – STOP – CLOSE” – fl ush mounted

Prepared for profi le half cylinder

Case dimensions: 80 x 152 x 35 mm (W x H x D)6-25838-00-0-0

Indication label “Smoke Vent”

– In compliance with DIN 4066

– Aluminium

– Dimensions: 210 x 75 x 1 mm (W x H x D)

9-22277-00-0-0

Indication label “Ventilation”

– Aluminium

– Dimensions: 210 x 75 x 1 mm (W x H x D)

9-25546-00-0-0

Page 80: Smok & Heat

80 Edition 12.2009

Accessories for RWA installations

Order information – Timer switch, voltage regulator, test kit, backup batteries

Description Order number

Timer switch with day/week programme and power reserve [1]

for time-related opening and closing of ventilation sashes/leaves/fl aps

– Suitable for combination with temperature-dependent control devices, e.g., for controlled

night cooling (taking into account winter and summer time)

9-45612-00-0-0

Voltage regulator

to adjust the battery charging voltage9-42085-00-0-0

Test kit

for 24 V DC/230 V AC drives

Functions:

– Digital display of maximum and instantaneous current

– Separate 24 V and 230 V power connections

– Push-to-lock switch and dead man’s switch

– Integrated battery pack

K-17736-00-0-6

Backup batteries [2]

– 12 V, 2,2 Ah

– 12 V, 6,0 Ah

– 12 V, 10,0 Ah

– 12 V, 17,0 Ah

– 12 V, 24,0 Ah

– 12 V, 38,0 Ah

for RWA control centre

RZ 2

RZ 5 / RZ 10

RZ 10 / RZ 24

RZ 24 (for max. 2 – 4 groups)

RZ 24 (for max. 4 – 6 groups)

RZ 24 (for max. 6 – 8 groups)

9-40284-00-0-0

9-40285-00-0-0

9-40286-00-0-0

9-45327-00-0-0

9-40287-00-0-0

9-40288-00-0-0

[1] To provide for the “AUTOMATIC OPEN” function, the compact control centres RZ 2 / RZ 5 need the connecting module “Ventilation” in addition.[2] Batteries must always be ordered by pairs.

Page 81: Smok & Heat

81Edition 12.2009

Ventilation Systems (230 V AC)

Chain drives ELTRAL K

Spindle drive ELTRAL S

Rack and pinion drive ELTRAL Z

Fanlight openingsystems

Ventilation control centres LZ 1 / LZ 6

Accessories for ventilation systems

Page 82: Smok & Heat

82 Edition 12.2009

Chain drives ELTRAL K

Chain drives ELTRAL K25 KS 30/40 [1] K30 K60

Operating voltage 230 V AC 110 / 230 V AC 110 / 230 V AC 230 V AC

Pushing force (N) 250 [2] 300 [2] 300 [2] 600 [2]

Pulling force (N) 250 300 300 600

Current consumption (A) 0,2 0,12 0,16 0,2

Opening width (stroke) (mm) 200 / 300 / 400 110 / 200 / 300 / 400 200 / 300 / 400 / 500 250 / 400

IP protection class 32 30 32 32

Ambient temperature -5 °C up to +75 °C -5 °C up to +65 °C -5 °C up to +65 °C -5 °C up to +75 °C

Suitable for roof-lights no no yes yes

Synchronising control optional optional optional optional

Concealed installation no no no no

DimensionsW x H x D

(mm) 435x26x41(stroke 200)

386,5x38,1x58,5(all strokes)

456x43x60(all strokes)

537x40x56(stroke 250)

Connecting cable Silicone, 3 m, 4-core

2 m, 3-core (Solo)2,5 m, 5-core (Synchro)

Silicone;2 m, 3-core (Solo)

2,5 m, 5-core (Synchro)

Silicone, 5 m,6-core

Detail informationsee page

83 / 84 / 91 85 / 86 / 91 87 / 88 / 92 89 / 90 / 92

Electric motor chain drives are ideally suited in the context of centrally controlled room ventilation.

Thanks to their compact design and the great number of face-fi xed or concealed mounting variants, they can be used – al-most regardless of the installation condi-tions – on inward or outward opening top or bottom hung windows, parallel offset windows, projecting top hung windows, horizontal or vertical pivoting windows, side hung windows, and roof-lights.

Intelligent electronics allows for the syn-chronised control 2 drives, also in combina-tion with locking actuators.

Product overview

[1] Chain drive with plastic case[2] Depending on stroke

Page 83: Smok & Heat

83Edition 12.2009

145

41

26

12

13

13

Total length L

7

12 6

12

Stroke

Product features Compact size

Stainless steel chain

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Automatic overload cut-off

Suitable for small sash heights

Total length 200 mm stroke L = 435 mm

300 mm stroke L = 480 mm

400 mm stroke L = 530 mm

Technical data

Chain drive ELTRAL K25

Product features, Dimensioned drawing, Technical data

Type of drive ELTRAL K25

Nominal voltage 230 V AC

Push/pull force 250 N / 250 N [1]

Current consumption 0,2 A

Stroke speed 8 mm/s

Duty ratio 30 %

Locking pressure 3000 N

IP protection class 32

Connecting cable Silicone, 3 m, 4-core

Case Aluminium EV1 anodised

Dimensioned drawing

Dimensions L x 26 x 41 mm L x H x D

[1] Depending on stroke Note: Order information see page 91

Page 84: Smok & Heat

84 Edition 12.2009

Chain drive ELTRAL K25

Application range [1]

350

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

2600

500

425

750

1000

1250

1500

1750

K25K25 Synchro

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

Application diagram Thrust diagram

100 200 300 400

100

200

300

500 600

0

0

Th

rust

(N

)

Stroke (mm)

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.

Page 85: Smok & Heat

38

.1

386.5

51

min

. 37

28

.5

58

.5

ø46

8.4

ø10

85Edition 12.2009

Chain drive ELTRAL KS 30/40

Product features, Dimensioned drawing, Technical data

Product features Compact size

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Automatic overload cut-off

Suitable for small sash heights

Variable stroke adjustment

Automatic gasket relief

Technical data

Type of drive ELTRAL KS 30/40

Nominal voltage 110 / 230 V AC

Push/pull force 300 N

Current consumption 0,12 A

Opening width (adjustable) 110 mm / 200 mm / 300 mm / 400 mm

Stroke speed 12 mm/s

Duty ratio 30 %

Locking pressure 1000 N

IP protection class 30

Connecting cable 2 m, 3-core (Solo) / 2,5 m, 5-core (Synchro)

Case PVC

Dimensioned drawing Dimensions 386,5 x 38,1 x 58,5 mm L x H x D

Note: Order information see page 91

Page 86: Smok & Heat

86 Edition 12.2009

Chain drive ELTRAL KS 30/40

Application range [1]

ELTRAL KS 30/40 ELTRAL KS 30/40 Remote

Application diagrams

Thrust diagram

ELTRAL KS 30/40

ELTRAL KS 30/40 Remote

50

0

40

0

60

0

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

16

00

17

00

18

00

20

00

19

00

21

00

22

00

23

00

24

00

25

00

26

00

500

250

750

1000

1250

1500

KS 30/40 KS 30/40 Synchro

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm4

00

50

0

60

0

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

500

250

750

1000

1250

1500

KS 30/40 Remote

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

100 200 300 400

100

200

300

400

0

0

Th

rust

(N

)

Stroke (mm)

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.

Page 87: Smok & Heat

456

43

60

228

28

.5

30

87Edition 12.2009

Chain drive ELTRAL K30

Product features, Dimensioned drawing, Technical data

Product features Compact size

Integral microprocessor controller

Synchronised tandem operation

Electronic limit stop switch

Independent of sash overlap dimension

Automatic overload cut-off

Suitable for small sash heights

Variable stroke adjustment

Automatic gasket relief

Technical data

Type of drive ELTRAL K30

Nominal voltage 230 V AC

Push/pull force 300 N

Current consumption 0,16 A

Opening width (adjustable) 200 mm / 300 mm / 400 mm / 500 mm

Stroke speed 12,5 mm/s

Duty ratio 30 %

Locking pressure 2000 N

IP protection class 32

Connecting cable Silicone; 2 m, 3-core (Solo) / 2,5 m, 5-core (Synchro)

Case Zinc die cast

Dimensioned drawing Dimensions 456 x 43 x 60 mm L x H x D

Note: Order information see page 92

Page 88: Smok & Heat

88 Edition 12.2009

Chain drive ELTRAL K30

Application range [1]

50

0

60

0

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

16

00

17

00

18

00

19

00

20

00

21

00

22

00

23

00

24

00

25

00

26

00

500

250

750

1000

1250

1500

K30 K30 Synchro

Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

Application diagram Thrust diagram

100 200 300 400 500

100

200

300

400

0

0

Th

rust

(N

)

Stroke (mm)

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.

Page 89: Smok & Heat

89Edition 12.2009

Product features Compact size

Stainless steel chain

Integral microprocessor controller

Electronic limit stop switch

Automatic overload cut-off

Pivotable mountings allow for small sash heights from 350 mm

Emergency release

Total length 250 mm stroke L = 537 mm

400 mm stroke L = 613 mm

Chain drive ELTRAL K60

Product features, Dimensioned drawing, Technical data

Dimensioned drawing

Dimensions L x 40 x 56 mm L x H x D

Technical data

Type of drive ELTRAL K60

Nominal voltage 230 V AC

Push/pull force 600 N [1]

Current consumption 0,2 A

Stroke speed 10 mm/s

Duty ratio 30 %

Locking pressure 3000 N

IP protection class 32

Connecting cable Silicone, 5 m, 6-core

Case Aluminium EV1 anodised

40

16

230

1819

Total length L56

[1] Depending on stroke Note: Order information see page 92

Page 90: Smok & Heat

90 Edition 12.2009

100 200 300 400 500 600 700 800 900 1000

100

200

300

400

500

600

0

0

Th

rust

(N

)

Stroke (mm)

55

06

00

70

0

80

0

90

0

10

00

11

00

12

00

13

00

14

00

15

00

500

425

750

1000

1250

1500

K60Sa

sh h

eig

ht

(SH

), m

m

Sash width (SW), mm

Application diagram Thrust diagram

Chain drive ELTRAL K60

Application range [1]

[1] All values are reference values which may vary depending on the profi le used and the height of the building. The maximum window size and the permitted lengths of unmounted profi le jambs (in view of suffi cient gasket pressure) must be agreed with the profi le manufacturer and/or window fabricator. The instructions of the particular profi le system, hardware and glass manufacturers must be observed. The maximum length of unmounted profi le jambs is 1500 mm.

Page 91: Smok & Heat

91Edition 12.2009

Chain drives ELTRAL K25 / ELTRAL KS 30/40

Order information – Drives

Description Stroke Order number

ELTRAL K25200 mm

300 mm

400 mm

K-17647-20-0-1

K-17647-30-0-1

K-17647-40-0-1

ELTRAL K25 Synchro

consisting of 2 chain drives

200 mm

300 mm

400 mm

K-17582-20-0-1

K-17582-30-0-1

K-17582-40-0-1

ELTRAL KS 30/40 110 mm

200 mm

300 mm

400 mm

K-17433-00-0-*

ELTRAL KS 30/40 Synchro

consisting of 2 chain drives 110 mm

200 mm

300 mm

400 mm

K-17435-02-0-*

ELTRAL KS 30/40 Remote 110 mm

200 mm

300 mm

400 mm

K-17437-00-0-*

Radio remote control with holder

for programming up to 4 individual drives

K-17439-00-0-0

Note: Mounting sets must be ordered separately – see catalogue section “24 V DC Drives”.

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)

Page 92: Smok & Heat

92 Edition 12.2009

Chain drives ELTRAL K30 / ELTRAL K60

Order information – Drives

Description Stroke Order number

ELTRAL K30 200 mm

300 mm

400 mm

500 mm

K-17834-00-0-*

ELTRAL K30 Synchro

consisting of 2 chain drives 200 mm

300 mm

400 mm

500 mm

K-17835-00-0-*

ELTRAL K60250 mm

400 mm

K-17649-25-0-1

K-17649-40-0-1

Note: Mounting sets must be ordered separately – see catalogue section “24 V DC Drives”.

Page 93: Smok & Heat

93Edition 12.2009

Spindle drive ELTRAL S / Rack and pinion drive ELTRAL Z

Electromotive spindle or rack and pinion drives mounted on large and heavy roof-lights or façade openings provide comfor-table automated room ventilation.

Spindle drive and rack and pinion drive ELTRAL

S80 Z60

Operating voltage 230 V AC ± 15 % 230 V AC ± 15 %

Pushing force (N) 800 600

Pulling force (N) 800 600

Current consumption (A) 0,12 0,23

Opening width (stroke) (mm) 300 / 500 / 750 180 / 230 / 350 / 550 / 750 / 1000

IP protection class 54 55

Ambient temperature -5 °C up to +75 °C -5 °C up to +65 °C

Synchronising control no mechanical

Dimensions W x H x L (mm) 43 x 76 x (190 mm + stroke) 43 x 142 x (135 mm + stroke)

Connecting cable Silicone, 1 m, 6-core 2 m, 3-core

Detail informationsee page

94 – 96 97 – 98

Product overview

Page 94: Smok & Heat

94 Edition 12.2009

23

ø16

40

Installation dimension 190 mm + stroke

ø6

76

Product features Compact size

Synchronised tandem operation

Electronic limit stop switch

Automatic overload cut-off

Total length 300 mm stroke L = 490 mm

500 mm stroke L = 690 mm

750 mm stroke L = 940 mm

Technical data

Spindle drive ELTRAL S80

Product features, Dimensioned drawing, Technical data

Type of drive ELTRAL S80

Nominal voltage 230 V AC

Push/pull force 800 N

Current consumption 0,12 A

Stroke speed 7 mm/s

Duty ratio 30 %

Locking pressure 3500 N

IP protection class 54

Connecting cable Silicone, 1 m, 6-core

Case Aluminium EV1 anodised

Dimensioned drawing

Dimensions (190 + stroke) x 43 x 76 mm L x H x D

Page 95: Smok & Heat

95Edition 12.2009

Spindle drive ELTRAL S80

Order information – Drives and mounting sets

Description Stroke / Joinery Order number

ELTRAL S80

300 mm

500 mm

750 mm

9-42094-30-0-1

9-42094-50-0-1

9-42094-75-0-1

Mounting set S/230 V for roof-lights

Aluminium K-17770-00-0-1

Mounting set RS/230 V for roof-lights

Aluminium K-17772-00-0-1

Page 96: Smok & Heat

96 Edition 12.2009

Description Joinery Order number

Mounting set W/230 V for roof-lights

Aluminium K-17773-00-0-1

Mounting set / universal

Aluminium K-17774-00-0-1

19

32

46

40

Spindle drive ELTRAL S80

Order information – Mounting sets

Page 97: Smok & Heat

97Edition 12.2009

Rack and pinion drive ELTRAL Z60

Product features, Dimensioned drawing, Technical data

Product features Compact size

Galvanised thrust tube

Tandem operation with connecting rod

Electronic limit stop switch

Automatic overload cut-off

Multiple operation with up to 4 drives

Note:

With heavy and large sashes it is possible to operate several drives in a row. A rack and pinion follower can be used as additional opening/locking element (both in single-drive and multiple-drive operating mode). Synchro-nisation between the drives or between drive and follower is effected by means of a mecha-nical connecting rod.

Total length 180 mm stroke L = 315 mm

230 mm stroke L = 365 mm

350 mm stroke L = 485 mm

550 mm stroke L = 685 mm

750 mm stroke L = 785 mm

1000 mm stroke L = 1135 mm

Dimensioned drawing

Dimensions 43 x 142 x (135 + stroke) mm W x H x L

Technical data

Type of drive ELTRAL Z60

Nominal voltage 230 V AC

Push/pull force 600 N

Current consumption 0,23 A

Stroke speed 11 mm/s

Duty ratio 30 %

Locking pressure 3000 N

IP protection class 55

Connecting cable 2 m, 3-core

25.517

33.6

32

Ø12

48

135 + stroke

43

54

260

45

97.5

Page 98: Smok & Heat

98 Edition 12.2009

Rack and pinion drive ELTRAL Z60

Order information – Drives

Description Stroke / Length Order number

ELTRAL Z60

180 mm

230 mm

350 mm

550 mm

750 mm

1000 mm

K-17845-18-0-1

K-17845-23-0-1

K-17845-35-0-1

K-17845-55-0-1

K-17845-75-0-1

K-17845-01-0-1

Rack and pinion follower ELTRAL Z60 180 mm

230 mm

350 mm

550 mm

750 mm

1000 mm

K-17844-18-0-1

K-17844-23-0-1

K-17844-35-0-1

K-17844-55-0-1

K-17844-75-0-1

K-17844-01-0-1

Connecting rodL = 1000 mm

L = 1500 mm

L = 2000 mm

L = 2500 mm

9-45469-10-0-1

9-45469-15-0-1

9-45469-20-0-1

9-45469-25-0-1

Ø1

3

Ø1

1

24°

L

Page 99: Smok & Heat

99Edition 12.2009

Fanlight opening systems

Fanlight opener VENTUS F 200 [*]

Fanlight openerVENTUS F 300 [*]

Easy and comfortable fanlight ventilation is provided by the fanlight fi ttings VENTUS F 200 and F 300 for bottom hung inward opening sashes, especially in combination with the electric drives ELTRAL S 230 or ELTRAL 300 E1.

Fanlightopening systems

VENTUS F 200 / VENTUS F 300with ELTRAL S 230 E / ELTRAL S 230 L

VENTUS F 200 / VENTUS F 300with ELTRAL 300 E1

Mains voltage 230 V AC ± 15 % 230 V AC ± 15 %

Thrust (N) 1200 3000

Duty ratio (%) 20 100

Current consumption (A) 0,15 0,1

Maximum stroke (mm) 70 40 – 100

IP protection class 50 54

Synchronising control no no

Dimensions L x W x H (mm) 210 x 36 x 76 270 x 55 x 102

Connection 4-pole plug Silicone, 1,5 m, 4-core

Detail informationsee page

100 – 105 100 – 105

Product overview

[*] For further information see our order catalogues “Builder’s Hardware for timber/PVC/aluminium windows and patio doors”

Page 100: Smok & Heat

100 Edition 12.2009

Product features Cost-efficient control of several window elements with one drive

Opening widths up to 200 mm / 300 mm, suitable for small sash heights from 300 mm / 350 mm

For sash weights up to 80 kg / 200 kg

Ideally suited for windows offering limited mounting space

High gasket pressure thanks to auto-matically and reliably locked stay arms

Overlap dimension 0 – 25 mm

Individually dosed ventilation thanks to continuously variable and lockable opening angles

Opening stay can be released easily for window cleaning

According to sash widths and weights, two drive variants with different motor power are available:

ELTRAL S 230 / ELTRAL 300 E1

Further features:

– Simple mounting, horizontal or vertical (rh / lh)

– Adjustable stroke for various opening widths

– Electronic limit stop switch and overload cut-off

Fanlight openers VENTUS F 200 / VENTUS F 300

Product features, Technical data

Technical data

Type of drive ELTRAL S 230 E ELTRAL S 230 L ELTRAL 300 E1

Nominal voltage 230 V AC 230 V AC

Nominal force 1200 N 3000 N

Current consumption 0,15 A 0,1 A

Stroke (adjustable) 50 mm / 70 mm [1] 40 – 70 mm [2]

Speed 0,9 mm/s 1 mm/s

Duty ratio 20 % 100 %

Synchronising control no no

Cutoff Electronic Overload cut-off Limit stop switch

Overload protection Thermostatic switch Thermostatic switch

IP protection class 50 54

Connection 4-pole plug Silicone, 1,5 m, 4-core

Dimensions (L x W x H) 210 x 36 x 76 mm 270 x 55 x 102 mm

Case Aluminium Aluminium

[1] Factory setting: 50 mm stroke = 200 mm opening width (VENTUS F 200); when mounted with VENTUS F 300, the stroke must be set to 70 mm (= 300 mm opening width).[2] Factory setting = 40 mm stroke. When mounted with VENTUS F 200, the stroke must be set to 50 mm (200 mm opening width) When mounted with VENTUS F 300, the stroke must be set to 70 mm (300 mm opening width)

Page 101: Smok & Heat

26

12

1

20

4

3150

1

41

5

26

5331

29

101Edition 12.2009

According to the directives of RAL, it is absolutely necessary that

bottom hung sashes must be fitted withcatch stays supple-menting the stan-dard fanlight fittings.

G.U security stays EURO-SOLID prevent damage that might arise from inappropriate attachment of the opening stays. Moreover, they provide great convenience when cleaning the tilted sash by holding it in the angle desired.

Fanlight openers VENTUS F 200 / VENTUS F 300

Dimensioned drawings, Installation dimensions, G.U security stay EURO-SOLID

Fanlight fittings VENTUS F 200 with electric drive ELTRAL S 230

Stroke 50M

210

76

Closing

M

18

12

193 8

36

32

1

32

26

34

Minimum sash width SW = 620

12

9

Opening

Drive mounted at topOpening stay closed

Opening stay opened

G.U security stay EURO-SOLIDInstallation dimensions VENTUS F 200 Installation dimensions VENTUS F 300

Page 102: Smok & Heat

102 Edition 12.2009

Fanlight opener VENTUS F 200

Range of application

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

3200

3400

3600

80

78

76

74

72

70

68

66

64

62

60

58

56

54

52

50

48

46

44

42

40

38

36

34

32

30

28

26

24

22

20

40 k

g/m

² (2

x8)

35 k

g/m

² (2x

7)

30 k

g/m

² (2x

6)

25 k

g/m

² (2x

5)

2x8

2x7

2x6

2x5

20 k

g/m

² (2x

4)

1 stay 2 stays 3 stays

Maximum sash width SW

max

.D

im. "

S"

min

.

Fanlight fi ttings VENTUS F 200 with ELTRAL S 230 E / S 230 L

Application range as a function of the centre of mass of the sash

Dim. "S"

Calculation exampleDimension “S”

Application rangeELTRAL S 230 / ELTRAL 300 E1

Weights / heights / widths of sash permitted

VENTUS F 200 with ELTRAL S 230 ELTRAL 300 E1

Max. sash weight 80 kg

Max. weight of glazing [1] 40 kg/m2

Min. Sash height

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

300 mm

300 mm

300 mm

Min. Sash width

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

400 mm

620 mm

620 mm

Max. Sash width 3600 mm

Space required for drive

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

39 mm

39 mm

57 mm

Max. number of stays 3

[1] Depending on Dim. “S” and sash width [2] on side [3] at top

Calculation exampleDimension “S”

Example:

Glazing 2 x 8 mm

Weight of glass 40 kg/m2

Sash width 2200 mm

Dim. “S” 20 – 57 mm possible

Sash weight

max. 80 kg

Weight of glass

max. 40 kg/m2

Page 103: Smok & Heat

103Edition 12.2009

14

00

16

00

18

00

20

00

22

00

24

00

26

00

28

00

30

00

32

00

34

00

36

00

100

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

12

00

10

00

80

0

70 k

g/m

2

60 k

g/m

2

50 k

g/m

2 (2x1

0)

40 k

g/m

2 (2

x8)

30 k

g/m

2 (2

x6)

30 kg/m 2 (2x6)

2 stays 3 stays

max

.D

im. "

S"

min

.

Maximum sash width SW

Fanlight fi ttings VENTUS F 300 with ELTRAL S 230 E / S 230 L Fanlight fi ttings VENTUS F 300 with ELTRAL 300 E1

24

00

26

00

28

00

30

00

32

00

34

00

36

00

38

00

40

00

42

00

44

00

46

00

48

00

50

00

52

00

54

00

56

00

58

00

60

00

100

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

22

00

20

00

18

00

120 kg/m2

110 kg/m2

100 kg/m2

90 kg/m2

80 kg/m2

70 kg/m 2

60 kg/m 2

50 kg/m 2

60 kg/m2

Maximum sash width SW

2 stays 3 stays 4 stays 5 stays

max

.D

im. "

S"

min

.

Application range as a function of the centre of mass of the sash

Fanlight opener VENTUS F 300

Range of application

Dim. "S"

Calculation exampleDimension “S”

Example:

Glazing 2 x 10 mm

Weight of glass 50 kg/m2

Sash width 2000 mm

Dim. “S” 25 – 60 mm possible

Sash weight

max. 200 kg

Application rangeELTRAL S 230 / ELTRAL 300 E1

Weights / heights / widths of sash permitted

VENTUS F 300 with ELTRAL S 230 ELTRAL 300 E1

Max. sash weight 200 kg

Max. weight of glazing [1] 70 kg/m2

Min. Sash height

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

468 mm

350 mm

400 mm

350 mm

Min. Sash width

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

620 mm

850 mm

605 mm

850 mm

Max. Sash width 3600 mm 6000 mm

Space required for drive

– Drive mounted vertically [2]

– Drive mounted horizontally [3]

39 mm

39 mm

57 mm

57 mm

Max. number of stays 3 5

[1] Depending on Dim. “S” and sash width [2] on side [3] at top

Page 104: Smok & Heat

104 Edition 12.2009

Description VENTUS Mounting PU Order number

Electric drive ELTRAL S 230 E

with electronic control of opening width

Overload cut-offF 200

F 300

Vertical /

horizontal1 6-31732-00-0-*

Electric drive ELTRAL S 230 L

Overload cut-off F 200

F 300

Vertical /

horizontal1 6-31730-00-0-*

Electric drive ELTRAL 300 E1

Cut-off via limit stop switchF 200

F 300Horizontal 1 9-31020-01-0-*

Basic box without lever handle, without sash bracket F 200 Vertical 1 K-15012-00-0-*

Basic box without lever handle, with angular sash bracket F 300 Vertical 1 K-14320-00-0-*

Bag of stay without sash bracket [1] F 200Vertical /

horizontal10 K-15013-00-0-*

Box of stay with angular sash bracket [1] F 300Vertical /

horizontal1 K-13999-00-0-*

Box of angular sash bracket F 200Vertical /

horizontal10 K-15225-00-0-*

Bag of linkage parts

consisting of connecting rod, coupling and guide

for electric drive ELTRAL S 230 E / S 230 L

F 200 Horizontal 1 K-14103-00-0-1

Bag of linkage parts

consisting of connecting rod and coupling

for electric drive ELTRAL 300 E1

F 200 Horizontal 1 K-15216-00-0-1

Bag of linkage parts

consisting of connecting rod, coupling and guide

for electric drive ELTRAL S 230 E / S 230 L

F 300 Horizontal 1 K-14203-00-0-1

Bag of linkage parts

consisting of connecting rod and coupling

for electric drive ELTRAL 300 E1

F 300 Horizontal 1 K-14202-00-0-1

Fanlight openers VENTUS F 200 / VENTUS F 300

Order information – Drives, Fanlight fittings

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016) [1] When a second or more stays are required

Page 105: Smok & Heat

105Edition 12.2009

Fanlight openers VENTUS F 200 / VENTUS F 300

Order information – Fanlight fittings, G.U security stay EURO-SOLID

Description VENTUS Mounting PU Order number

Connecting rod ø 8 mm

for electric drive ELTRAL S 230 E / S 230 LF 200 Vertical 1 9-34764-00-0-1

End cap F 200 Horizontal 1 9-34412-00-0-*

Connecting rod ø 12 mm

for electric drive ELTRAL 300 E1F 300 Vertical 1 9-35331-00-0-1

End cap F 300 Horizontal 1 9-34479-00-0-*

Horizontal rod ø 8 mm

– Length 600 mm

– Length 1850 mm

– Length 3300 mm

– Length 6000 mm

F 200Vertical /

horizontal

10

10

10

10

9-25476-06-0-1

9-25476-18-0-1

9-25476-33-0-1

9-25476-60-0-1

Cover profi le

– Length 62 mm

– Length 800 mm

– Length 1800 mm

– Length 3050 mm

– Length 6000 mm

F 200Vertical /

horizontal

10

10

10

10

10

9-33444-01-0-*

9-33444-06-0-*

9-33444-18-0-*

9-33444-33-0-*

9-33444-60-0-*

Horizontal rod ø 10 mm / Cover profi le for horizontal rod

– Length 600 mm

– Length 1870 mm

– Length 3500 mm

F 300Vertical /

horizontal

1

1

1

K-14001-06-0-*

K-14001-18-0-*

K-14001-33-0-*

Alternatively:

Horizontal rod ø 10 mm / Length 6000 mm

Cover profi le / Length 6000 mm

F 300Vertical /

horizontal1

1

9-23055-60-0-1

9-34497-60-0-*

G.U security stay EURO-SOLID

for bottom hung timber/PVC/aluminium windows

– Sash height 270 mm – 350 mm

– Sash height 351 mm – 500 mm

– Sash height 501 mm – 800 mm

– Sash height 801 mm – 1500 mm

F 200

F 300

Vertical /

horizontal

100

100

100

100

6-27995-01-0-1

6-27995-02-0-1

6-27995-03-0-1

6-27995-04-0-1

Bag of profi le-related accessories EURO-SOLID

– for bottom hung timber windows

– Packer for Euro groove 7/8 x 4, 6/8 x 4 / timber

– for bottom hung PVC windows

– for bottom hung aluminium windows

F 200

F 300

Vertical /

horizontal

20

100

K-14681-00-0-1

9-38819-00-0-1

upon request

upon request

* = Colour: 1 = grey (RAL 7047), 6 = black (RAL 9005), 7 = white (RAL 9016)

Page 106: Smok & Heat

106 Edition 12.2009

Central control units LZ (Ventilation)

Control of 24 V DC drives for the purpose of ventilation.

Central control units LZ enable several ventilation functions and ventilation groups such as, e.g., wind/rain detector, timer switch, building management appliances to be controlled from one central station, thus being an ideal solution for the ventila-tion of individual and/or several rooms.

Technical data

Type LZ 1 LZ 6

Supply voltage 230 V AC ± 10 %, 50 Hz

Output voltage 24 – 28 V DC

Output current 2,5 A 18 A

Max. no. of groups 1 ventilation group6 ventilation groups,

max. 3 A each

Connections

3 terminals for switching contacts with ascending priority, e.g.:1. priority (P1) = superordinate building management system

2. priority (P2) = wind/rain detector3. priority (P3) = ventilation switch for dead man’s and/or locking operating mode

GroupingSeveral central control units LZ 1, also in

combination with central control units LZ 6Several central control units LZ 6, also in

combination with central control units LZ 1

Connection terminals– mains– drive

max. 1,5 mm2

max. 2,5 mm2

max. 1,5 mm2

max. 6,0 mm2

Duty ratio 30 %

IP protection class 54 30

Case PVC Aluminium

DimensionsLZ 1 – Surface-mounted type

160 x 160 x 60 mm W x H x D

LZ 6 – Surface-mounted type

370 x 454 x 110 mm W x H x D

Product overview

Page 107: Smok & Heat

107Edition 12.2009

Central control units LZ (Ventilation)

Order information – Central control units and accessories

Description Mounting / Type Order number

Central control unit LZ 1

Surface-mounted 6-35080-00-0-0

Central control unit LZ 6

Surface-mounted 6-35081-00-0-0

Rocker switch “OPEN –STOP – CLOSE”

1-poleSurface-mounted

Flush mounted

6-25539-00-0-0

6-22540-00-0-0

Rocker switch (biased) “OPEN –STOP – CLOSE”

1-poleSurface-mounted

Flush mounted

6-25220-00-0-0

6-25219-00-0-0

Hand-held radio transmitter 42 FH

for electric drives 230 V AC9-42496-00-0-0

Radio actuator FAJ 6 UP

– in combination with radio transmitter 42 FH

– for installation in fl ush box

– 230 V AC, 50 Hz

9-42495-00-0-0

Power supply units 230 V AC / 24 V DC

in surface-mounted plastic case for the connection of 24 V DC

spindle/chain drives and locking actuators

NT 1,25

NT 2,4

NT 5

9-43993-00-0-0

9-43994-00-0-0

9-43995-00-0-0

Power supply units 230 V AC / 24 V DC

Technical data

Description NT 1,25 NT 2,4 NT 5

Mains voltage 230 V AC, 50 Hz

Output voltage 24 V DC

Output current (A) 1,25 2,4 5,0

Apparent output (VA) 30 54 120

Duty ratio 30 %

IP protection class 54

Grouping max. 8 power supply units

Dimensions(W x H x D) (mm) 136 x 180 x 90 120 x 200 x 86 220 x 168 x 106

Page 108: Smok & Heat

108 Edition 12.2009

RWA systems

Important advice

Service and maintenance

In order to guarantee the permanent functioning and the value of RWA installations over many years, it is necessary that all technical compo-nents are serviced and tested for safe functioning at regular intervals.

Moreover, it is important to recognise potential danger or missing safety mechanism which might become a source of danger, and to eliminate any risks.

The operator and/or owner is obliged to verify the proper and faultless interaction of all components at least once a year. He must take all necessary measures to protect people using the installations against danger and property against damage.

Regular servicing provides functional safety and diminishes the risk of damage and of liability in the event of a damage. With a service con-tract, the operator’s and/or owner’s fulfi lment of the duty to maintain the installation ready for operation is always documented and proved.

The legal basis for RWA installation servicing is established in direc-tives and regulations which vary from country to country.

The directives and regulations applying in Germany are: “Muster- und Landesbauverordnungen (MBO/LBO)” of the particular states; direc-tive BGR 232 for power-operated windows, doors and shutters (Ger-man employer’s liability insurance association); various directives for safety at work.

As for safety testing, it is necessary to proceed according to the specifi cations of the applicable regulations and standards (e.g., DIN 18650), and to the specifi cations of the manufacturer.

The technician performing the safety checks must be a trained and qualifi ed professional. In general, service and maintenance work may only be carried out by an expert authorised by the manufacturer.

Safe operation and use

With regard to bottom hung sashes, the RAL directives and also the directive BGR 232 for power-operated windows, doors and shutters (German employer’s liability insurance association) prescribe the use of additional catch stays to prevent sashes from uncontrolled falling:

Safety devices such as, e.g., the security stay EURO-SOLID from Gretsch-Unitas must be installed appropriately to ensure their re- liable functioning. The opening width of the catch device must be wide enough to allow for the maximum stroke of the opening motor.

Assembly, installation and initial operation may only be performed by trained experts authorised by the manufacturer.

Motors, central control units and accessories must always be in a faultless technical condition to ensure safe functioning and to pre- vent hazard; they may only be used as intended and in compliance with the particular mounting and operating instructions.

It is necessary that the local regulations and directives should be observed, e.g.:

– Directives for safety at work – Accident prevention regulations – Regulations concerning electrical and electronic engineering (e.g., VDE directives), DIN/EN standards – Directive BGR 232 for power-operated windows, doors and shutters (German employer’s liability insurance association) – Instruction sheet KB.01 of the German association of window and façade manufacturers (VFF) concerning power-operated windows

It is important to always ensure that RWA installations comply with the prevailing regulations. Special attention must be paid to win- dow opening width, permitted installation dimensions, opening speed, pushing force, connecting cable cross section as a function of the cable length, and to current consumption.

The electric drives are designed for use in dry rooms only. They must be protected against dirt and humidity.

Planning and installation

The supply cables must comply with the local fi re protection regulations and feature cross sections which are adequate for the required motor currents.

Manual RWA alarm pushbuttons must be installed at central points where they are clearly visible and freely accessible.

Automatic smoke detectors must be positioned in a way that they can be reached by smoke. Planners and installers must be aware of the space to be covered and provide for a suffi cient number of detectors placed at the right spots.

See also DIN VDE 0833, part 2.

For further information regarding assembly, commissioning and service please refer to our mounting and operating instructions, as well as to the particular installation drawings and wiring diagrams.

Page 109: Smok & Heat

109Edition 12.2009

Product overview / Software and Service

Window technology Door technology

Automatic entrance systems Management systems

Page 110: Smok & Heat

110 Edition 12.2009

Window technology

Comprehensive product range: Tilt-turn, tilt only, fi rst tilt, and side hung fi ttings, also for round arch head and oblique angle head windows; all available in standard version or in tested / untested security grades

Advantages: – automatic mushroom locking pins – central locking mechanism from standard (basic) secu- rity up to WK 2 – tilt-turn stays with integral slit ventilation

Technical details, fi tting variants

Fitting variants Sash width mm Sash height mm Sash weight kg

Timber or PVCUNI-JET M, UNI-JET SUNI-JET DUNI-JET S-CONTURAUNI-JET S-CONCEALED

280-1600280-1600280-1600400-1400

350-2450350-2450350-2350350-2450

up to 130up to 100up to 130up to 130

AluminiumJET AK 8UNI-JET CUNI-JET D

355-1700280-1600280-1600

500-2400350-2450350-2450

up to 13080 / 130 optional

up to 100

Parallel Slide and Tilt FittingsFittings for parallel slide and tilt units with 2 to 4 sashes.

Technical details, fi tting variants

Fitting variants Sash width mm Sash height mm Sash weight kg

Timber and PVCG.U-966/200 mZG.U-966/150 mZG.U-966/150 oZG.U-90 oZ

720-2000720-1600640-1600640-1600

820-2370820-2370700-2350700-2350

up to 200up to 150up to 130up to 90

AluminiumG.U-968/200 mZG.U-968/150 mZG.U-968/150 oZG.U-90 oZ

740-2000740-1600600-1600600-1600

895-2400895-2400730-2400730-2400

up to 200up to 150up to 130up to 90

All fi ttings with surface sealing ferGUard*silver

Sash components with clip connection

Tilt-Turn Fitting System UNI-JETFittings for single and double sash windows and patio doors made of timber, PVC and aluminium – suitable for manual and automatised hardware assembly in any window fabrication facility.

One handle operation, stays with forced control (mZ)

Up to 200 kg sash weight without additional runner

Designed for sash rebate widths up to 2000 mm (from SRW 1.850 mm with 3rd stay)

Sashes in tilt position secured against being pushed open

Multi-level security concept

Wrong operation safety device

Page 111: Smok & Heat

111Edition 12.2009

Window technology

Slide-Fold FittingsFittings for slide-fold units with 3 to 7 sashes.

Lift-Slide Fitting Range, HS-Master and HS-Master CONCEALEDFittings with one handle operation for units with 2 to 6 sashes.

Technical details, fi tting variants

Fitting variants Sash width mm Sash height mm Sash weight kg

Timber and PVCG.U-922G.U-925

400-900400-900

850-2450850-2350

up to 80up to 80

AluminiumG.U-822G.U-825

400-1000400-1000

730-2400730-2400

up to 80up to 80

Technical details, fi tting variants

Fitting variants Sash width mm Sash height mm Sash weight kg

Timber, PVC and aluminiumHS G.U-934HS G.U-937HS-MasterHS-Master CONCEALED

700-3300700-2200

min. SW 950-3300min. SW 1200-3300

850-2765 850-2765up to -2765 1840-2765

up to 300 *up to 150up to 300up to 300

All fi ttings with surface sealing ferGUard*silver

Threshold G.U-thermostep, G.U-threshold 47, G.U-fl atstep, G.U-timberstep

HS-Speed Limiter (mechanical safety component) prevents the sash from accele- rating its movement

Extended application range of lift-locking gear for sash heights up to 2765 mm

Newly engineered runners allow the sliding sashes to run more smoothly and quietly than ever before

Security package for all lift- slide units

HS slit ventilation module – convenient room aeration and enhanced burglar pro- tection (WK2-tested)

HS-Master – operating con- venience due to motor driven lift and slide

HS-Master CONCEALED – operating convenience due to motor driven lift and slide, plus the extra benefi t of so- phisticated design: the drive unit is integrated in the frame profi le

2-wheel runners, bottom running (G.U-922, G.U-822) or top running (G.U-925, G.U-825)

Vertical adjustment as well as sash overlap and gasket pressure adjustment on runners, horizontal adjust- ment on sash hinges

All fi ttings with surface sealing ferGUard*silver

* Special 400 kg / 600 kg variants

Page 112: Smok & Heat

112 Edition 12.2009

Window technology

Technical details, fi tting variants

Fitting variants Sash width mm Sash height mm Sash weight kg

Horizontal pivot fi ttings – timberUNITAS 5 Bo, 7 BoUNITAS 10/22°UNITAS 4 (circular window)FERCO 44 EFERCO 45 E

576-2950576-2950

424-2016 Ø576-1450576-1450

700-2200700-2200

700-2000700-2200

up to 175up to 300up to 100up to 80up to 120

Horizontal pivot fi ttings – PVCUNITAS 15, 16 576-2950 * 700-2200 * up to 175

Horizontal pivot fi ttings – aluminiumUNITAS 18 580- * 600- * up to 175

WendebeschlägeUNITAS 93 Bo (timber)UNITAS 88 (aluminium)

782-1600600- *

1250-2350600- *

up to 175up to 175

* max. SW and SH as specifi ed by profi le manufacturers

Horizontal and Vertical Pivot FittingsFittings for horizontal and vertical pivot windows with peripheral gasket:

DUCO VentilatorsFlap ventilators, rotating drum ventilators and sound-absorbing ventilatorsVentilators manufactured from extruded aluminium profi les foradjustable, energy saving and sound reducing ventilation (availableup to sound absorption class 4).

Thermally broken fl ap or rotating drum ventilators with sealing lips or fi nseal brushes

Controlled via lever, rod or cord

Max. length of ventilator: 3000 mm

A hardware system which has proven its value for de- cades; suitable for sash weights up to 300 kg

Vertical pivot fi ttings can be pivoted centrally or eccentri- cally

Technical data of ventilators

DescriptionG.U-DucoFlat DucoPlus

60 GFDucoTon

80 GFDucoMax

Silenzio 200 Uno80 GFO 80 GF 80 BF 100 GFO 100 GF/GFS 100 BF

Application / Features Flap ventilatorsFlap

ventilator

Rotating drum

ventilator

Sound absorbing ventilator

Sound absorbing ventilator

Installation in frame X X X

Installation on frame

Installation in glass rebate X X X X X X X

Installation on masonry X

Glass reduction (mm) 90 80 100 100 60 80 135

Glass thickness (mm) 20,24,28 20,24,28 20,24 20,24,28 20,24,28,32 20,24,28,32 20-42

Installation thickness (mm) 20,24 21

Connection to glazing at bottom X X X X X

Connection to glazing at top X X

Connection to glazing on side X

Airfl ow rate (m³/h) at 2 Pa 56,5 61,6 69,5 50 56,5 - 163,1 35,2

Sound reduction factor (open) Dne,A (dB)

27,3 26,7 27,2 26,1 33 - 45,7 43,1

Sound reduction factor (closed) Dne,A (dB)

44,8 41,7 44,3 31,9 45,8

Installation in the frame or glazing rebate of timber, PVC and aluminium windows

Tightness against driving rain up to 650 Pa

Page 113: Smok & Heat

113Edition 12.2009

Window technology

Secure hold of tilt sashes with the opening stay dis-engaged (e.g. for window cleaning) by means of G.U security stay EURO-SOLID

Fan-light OpenersSlimline fan-light opener with face-fi xed stays for tilt (bottom hung inward opening) units with one or more sashes.

Technical details, fi tting variants

Fitting variants Sash width mm Sash height mm Opening width mm

Timber, PVC and aluminiumVENTUS F 200VENTUS F 300

400-3600620-3600

ab 250ab 350

165 / 200220 / 300

Vertical and horizontal rods covered with aluminium profi le

Operation via lever handle, vertical gear or corner gear. Electric drives for individual or group control.

Fittings for rectangular, oblique angle head, arch head and segmental arch head tilt windows, also in enhanced security (“Se”) version

Fittings for top hung outward opening windows

Comprehensive product range consisting of:

Spindle drives, rack and pinion drives, and chain drives

Locking actuators

Opening and locking hard- ware

Compact and modular control centres

Accessories: push buttons, smoke and heat detectors (differential), rain and wind sensors

Advantages of RWA systems:

Enable assisted and unassis- ted rescue in case of a fire emergency

Provide for automatic ventilation

Can easily be fit into window or façade assemblies and in- tegrated in facility manage- ment systems

Smoke and Heat Exhaust (RWA) SystemsWherever utmost reliabilty and fast evacuation of smoke gases are demanded from a smoke exhaust installation in case of fi re, RWA sys-tems provide for safe, automatic opening of smoke exhaust apertures.

Page 114: Smok & Heat

114 Edition 12.2009

Window technology / Door technology

Accessories for Builder’s Hardwarefor timber, PVC and aluminium windows and doors.

Our well-assorted accessory range comprises modern high-quality products made from industry-leading manufacturers.

Fixing materials

Glazing tools

Door hinges

Electric door openers

Building chemicals

Composite panels

Gaskets

Window hinges

Insect screens

Multipoint Door LocksMultipoint door lock ranges G.U-SECURY and SECURY-EUROPA for burglary-inhibiting main and secondary entrance doors of timber, PVC or aluminium, and for house and fl at entrance doors with timber and steel frames.

All locking elements throw at least 20 mm and securely engage into strike plates or into a locking rod over the entire height of the door

Panic functions

Backsets from 25 to 90 mm, centres from 70 to 94 mm, spindle from 7 to 10 mm

Available in various forend widths and forend lengths

Safety door locks for burg- lary-inhibiting doors – WK 2 and WK 3 tested, VdS tested to class A

Handle-operated lock types (SECURY-EUROPA) with ma- nual locking; key-operated lock types (G.U-SECURY) with manual, motor-driven or mechanical-automatic locking

All deadbolt and latchbolt variants are secured against being pushed back

Page 115: Smok & Heat

115Edition 12.2009

Door technology

Aluminium Floor Thresholds with Thermal Breakfor all house entrance doors and tilt-turn patio doors of timber and PVC, suitable both for new buildings and renovation.Thermally broken thresholds considerably reduce the heat fl ow at the bottom of glazed doors.

Applications:

The threshold programme offers variants for

New buildings and renovation

House entrance and patio doors of timber and PVC

Barrier-free living to DIN 18025

Versatile accessories provi- ding solutions for complicated installation conditions

Threshold-to-frame connec- tors for all current profi les

The importance of thermal break:

With normal interior air conditions (interior temperature + 20 °C, re-lative air humidity 50%), con-densate forms with a surface temperature of approximately + 9.2 °C (dew point temperature).

With normal outside temperatures (down to -10 °C in winter), the effi -cient thermal break of G.U thres-holds achieves a surface tempera-ture clearly higher than + 9,2 °C. The formation of condensate is prevented, the bottom area of the door will not suffer from moisture, a sound building structure will be protected and preserved.

Mortise Locks

Standard locks

DIN standard locks for timber, steel and narrow stile house or fl at entrance doors, and internal doors

Heavy duty locks

For all kinds of project doors – heavy duty locks class 5 are designed for the use on highly frequented doors

Self-locking locks Series 21 for timber and steel doors,Series 19 for narrow stile doors

2 point locking with Automatic latchbolts

Suitability: from standard entrance doors up to so- phisticated escape doors

Electro-clutch (EK) panic locks Series 21 for timber and steel doors, Series 19 for narrow stile doors

Approved for VDS class C

For single and double leaf doors

Multipoint locking for timber and steel doors

Self-locking motor locks Series 19 for narrow stile doors

For single and double leaf doors

Suitable for use in the context of access control and barrier- free construction, or in connection with a swing door drive

Page 116: Smok & Heat

116 Edition 12.2009

Door technology

Espace Door Systems to EN 179 and EN 1125

Panic locks and latch plates

For single and double leaf door units

Multipoint safety door locks SECURY Series 21 for timber and steel doors, and SECURY Series 19 for narrow stile doors

3-point locking with three latchbolts

For use on burglary protec- tion doors and escape doors; for single and double leaf units

Self-locking lock Series 21 for timber and steel doors,Series 19 for narrow stile doors

2-point locking with Automatic latchbolts

Suitability: from standard entrance doors up to so- phisticated escape doors

Narrow stile lock Series 18

Approved for standard narrow stile, fi re protection and smoke protection doors

Choice of escape door func- tions for various requirements on single and double leaf narrow stile doors

Panic lock Series 23

For timber and steel doors. For various requirements on single and double leaf fi re protection, smoke protection and escape doors

Push bars, touch bars, door fi ttings

For single and double leaf door units

Locking Cylinders and Master Key Systems

Cylinder Series 50(reversible key system)

Profi le cylinder for single differ, keyed alike locking, registered differ and all suited applications

Cylinder Series 51 SL(reversible key system)

Security cylinder with addi- tional locking members; within master key suites combinable with series 50

Master key system variants

Central locking system for multifamily residences

Master key system for minor offi ce or factory buildings

Grand master key system for large buildings

Cylinder Series 88

Conventional profi le cylinders for single differ and keyed alike applications

Cylinder Series 31

Profi le, round and special type cylinders for all locking applications and types of master key suites

Cylinder Series 33 SL

Security cylinder with addi- tional locking members; within master key suites combinable with series 31

Cylinder Series 45 janus(reversible key system)

Security cylinder for regis- tered differ and complex master key systems

Variable cylinder length (Sandwich design)

Page 117: Smok & Heat

117Edition 12.2009

Door technology

Mechatronic Locking System SE– Cost-efficient solutions thanks to the combined use of mechanic,

mechatronic and electronic lockins systems within one master key suite

– One common transponder key for all SE products– Identical, easy programming of all components with one program-

ming device

Electronic cylinder SE

Low-cost integration in master key suites (also retrofitting)

Suitable for escape doors

Twofold security thanks to mechanic and electronic verification of access authorisations

Double cylinder SEwith turn knob

Combination with/retrofitting of all master key suites of Series 31, 33, and also of external master key suites possible

Aesthetic solutions for design-oriented door furnishing (e.g. glass doors)

SE wall reader

Electric gates, elevators, parking barriers and auto- matic doors for barrier-free application can be operated with the SE transponder key, just like the cylinders

KeyManager 3.6

Overall adminstration of mechanic, mechatronic and electronic cylinders and readers

KeyManager 3.6 allows for the direct programming of SE products

One user interface for the display and print of mechanic and electronic access autho- risations

Door Furniture

Security furniture

Complete programme of attractive designs for im- proved security

Tested to EN 1906 – pro- tection classes 1, 2, 3, 4 and standard version

Project furniture to EN 1906

Versatile range of project furniture with choice of handle designs and back- plates in a variety of mate- rials

Furniture for internal doors

In aluminium, stainless steel and brass

Escape door systems to EN 179 and EN 1125

Door handles and push bars for single and double leaf door units

Designer furniture

In stainless steel for sophisti- cated projects

Also for private applications – the backplate can be made to your own design and com- bined with any of our handle models

Push bars and escutcheons

Push bars in a choice of designs

Escutcheons with EN certifi - cation

Security furniture for narrow stile doors

Security furniture with EN 1906 certifi cation

In stainless steel, brass and aluminium

Page 118: Smok & Heat

118 Edition 12.2009

Door technology

Overhead Door Closers OTS, Floor Springs UTS, Rebate Door ClosersVersatile range of door closers for single and double leaf doors and hold-open systems.Overhead door closers are suitable for single action swing doors, fl oor springs are suitable for both single and double action swing doors.

Closer types and technical data

Door closer type Linkage Closing force ** for fi re and smoke protection doors **

Overhead door closers OTSOTS 730OTS 630OTS 633/634OTS 530OTS 430, 440/440GOTS 330/210OTS 200/200GOTS 140OTS 80/81

Slide railSlide railSlide rail

Scissor action armScissor action arm/Slide rail

Scissor action armScissor action arm/Slide rail

Scissor action armCrank gear

3 - 62 - 4

3 / 2 - 42 - 6 / 4 - 7

2 - 5 / 22 / 3 / 43 - 4 / 1

1 / 2 / 3 / 42 - 6 / 3 - 5

-

, - / - / ---

- / to DIN 18263, part 1

Rebate door closersRebate door closer 24/20

Concealed installation in the vertical door rebate 2 - 4 / 1 - 2 -

Door closer type Max. load capacity Closing force ** for fi re and smoke protection doors **

Floor springs UTSUTS 85UTS 42UTS 50/60UTS 840 *

300 kg120 kg

120 / 170 kg120 kg

2 - 5 / 3 - 61 - 43 / 4

3 and 4

---

* only for double action swing doors ** Size to EN 1154

Standard /optional features:(depending on closer type and variant)

Integrated door leaf coordina- tion

Mechanical or electro-mecha- nical hold-open device

Interchangeable spindles and spindle extensions

Hold-Open SystemsSmoke and fi re detection accessories for hold-open systems. In the event of a fi re, electrical hold-open devices or holding magnets are disconnected from the mains, thus releasing the door via door closer.

Manual actuation button, surface or flush mounted

Door holding magnets, e.g.: – standard variant with steel base plate – variant with aluminium swivel head – floor-mounted variant

Armature plates

Accessories for hold-open systems:

Smoke control switch unit BMZ 730 H with integral fi re detector

Wall or ceiling-mounted optical smoke detectors

Trigger power supply unit for the voltage supply of smoke switch systems

Page 119: Smok & Heat

119Edition 12.2009

Door technology

G.U-BKS ACCESS – Electronic Access ControlTwo system variants to meet particular security requirements:– Stand-alone card system for individual doors– Networked system for complex security zones

Numerous setting functions, e.g. for time zones, access areas, access groups, indi- vidual access, visitor mana- gement, security patrols

Usable in combination with electromechanic locks, escape door systems and automatic door drives, all supplied by the G.U Group

Door release via: – Key pad (PIN code) – Card reader – Biometric fingerprint reader (networked)

Simple operation

Escape door control system FTNT10

Control unit with integral emergency button

Unambiguous signalling

Compatible with many customary wall switch programmes

Approved in accordance with EltVTR

Easy installation, start-up and servicing

G.U-BKS NET interface

Escape Route SecurityCombined with electrically locking panic locks, the FTNT10 escape door control system from G.U-BKS offers effi cient protection against misuse of escpape doors whilst providing unrestricted burglar inhibition.

Electrically locking panic lock EVP

Self-locking locks of Series 21 for timber and steel doors, and Series 19 for narrow stile doors – Latch of electric lock is ideally integrated in the panic lock case (rather than being located at a separate locking point) – Reduced number of system components – Planner and fabricator- friendly lock system

Unlocking Alarm Locking

Controller and exit readerin one unit

Card reader

Page 120: Smok & Heat

120 Edition 12.2009

All-glass system solutions

All-Glass System SolutionsWith product design and functionality ideally complementing each other, the Gretsch-Unitas glass hardware range offers new application possibilities of toughened glass assemblies in a building.

A versatile system of door rails and wall connectors allows for the creation of glass partitions with all kinds of door functions

The glass door lock series PRIME Offi ce even provides the possibility to integrate a single glass door or a glass door assembly into a building management system. Electri- cal and electro-mechanical systems with panic functions open up innovative and archi- tecturally attractive solutions with maximal functionality.

Complementing products such as door closers and handles round off the pro- gramme

All-Glass Sliding PartitionsPartition wall systems allow for individual applications in commercial buildings, banks and shop in shop areas in shopping centres.

Manual and fully automatic all-glass sliding partitions

Variable room division

Separation of areas to create representative show rooms

Unlimited creative solutions according to requirements due to linear, curved or seg- mented variants

Convenient opening and closing at the push of a button or manual operation – all at the customer’s option

Page 121: Smok & Heat

121Edition 12.2009

Automatic entrance systems

Automatic Entrance SystemsGU Automatic sliding door systems offer functionality, cost-effectiveness and security wherever they are applied. Based on microprocessor-controlled drive units with small installation height, the comprehensive delivery programme provides convenient and barrier-free entrance solutions. Slim frame profi les emphasise the sophisticated door design.All door systems are TÜV-tested (German Technical Supervisory Association) for the use with emergency and escape routes !

Sliding doors

Creation of fi ne entrances with slim drive units

User-friendly opening and closing

Telescopic sliding doors

Large passage areas even in restricted structural openings

Stylish appearance due to slim frame profi les

Curved sliding doors

For entrances with sophisti- cated architecture

Slim drive unit with integral safety sensors

Prismatic sliding doors

Passage convenience com- bined with impressive en- trance design

Available in any angle from 90° to 179°

Swing Door DrivesDrive units for single and double leaf swing doors, suitable for the installation in all locations. Safe and simple operation. Easy retrofi tting of manual doors in the course of renovation. Suitable for the use with fi re and smoke protection doors. A drive variant for infl oor assembly is also part of the programme.

Low-noise operation

Suitable for exterior and interior doors

Easy assembly, start-up and maintenance

Integrated function selection switch with LED indication

Mechanic release from hold-open position

Adjustable wind pressure function

Dynamic adaptation of hold open time

Connection of motor driven lock, SECURY A-opener, electric door opener and safety sensors possible

Slot for radio receiver card

Rugged case in fashionable G.U-BKS design

Page 122: Smok & Heat

122 Edition 12.2009

Automatic entrance systems / Management systems

G.U-BKS NETThe management system G.U-BKS NET interconnects our electro-mechanical systems by means of modern bus communication, thus ensuring the automatic interplay of different functions.

Its modern system structure comprises centralised system confi gura-tion as well as centralised system monitoring.

The bus system allows for controlling and visualising a great number of mechatronical products via interface connection to the facility ma-nagement system GEMOS.

Revolving Door SystemsRevolving doors are suitable for a large variety of applications. Meeting individual demands in dimensions and design, they provide functional building entrances with effi cient protection against noise and air draught.

Revolving doors

Operation: manual or with fully automatic drive system

Convenient and safe passage due to 3 or 4-chamber system

Individual creative solutions for sophisticated building architecture

Innovative door design, e.g., all glass assemblies with glass roof and infl oor drive

Security DoorsSecurity revolving doors and security interlocked curved sliding doors for all areas where a high degree of security is required, e.g. in banks, ministries, computer centres.

Controlled admission of authorised persons via integral electronic access control system

Protection of main and side entrances without additional staff

Page 123: Smok & Heat

123Edition 12.2009

Management systems

Thanks to its versatility, GEMOS enables the customised, effi cient and convenient implementation of facility-specifi c requirements. Moreover, the Gretsch-Unitas Group of Companies offers all relevant services such as engineering, installation, and, of course, project maintenance. A large number of international references from various application areas attest to the performance ability of this integrative approach.

GEMOS – Security System Solutions for Buildings and FacilitiesThe facility and security management system GEMOS integrates all mechatronic and electronic equipment items of a building, whereby the focus is put on security installations. The web-based management inter-face not only allows to monitor and administer all integrated systems in a truly reliable manner, but also controls the interplay of facility equipment items of different trades.

G.U-BKS NET

Fire detection systems

Intrusion alarm systems

Facility management systems

I/O Modules

Communication systems

Video systems

Access control systems

Reception desk systems

Escape door control systems

Perimeter systems

Emergency alarm systems

UGM

Smoke and heat exhaust vent systems

Page 124: Smok & Heat

124 Edition 12.2009

Software and Service

Planning software

Tendering service

Web-based tendering module for the creation of complex specifi -

cations in the formats Word / Excel / Gaeb81 / Gaeb82, with inte-

grated Gaeb import function.

Advantages:

Online with no need for installation

Consistent support for the specifi cation process

Professional creation of BOQs

Single items already composed previously are available as

premade system texts

Permantent upgrade of specifi cation descriptions

Full functionality of the tendering software

Format-consistent data exchange with import/export interfaces

according to the GAEB standard

Service email:

[email protected]

confi GUrator

Product fi nder for determining, quoting, and ordering hardware sets

and parts lists for windows, doors and automatic entrance systems.

Advantages:

Data calculation based on up-to-date prices, conditions and

state of the art

Confi guration of special designs, e.g. oblique angle head win-

dows or round arched windows, taking into account particular

technical restrictions

Confi guration of panic exit devices, fi re doors and multipoint

locked doors to EN 179 and EN 1125 for narrow stile, timber,

and steel door assemblies

Administration of individual quotations and addresses

Service email:

confi [email protected]

KeyManager

Professional software for confi guring, administering, and recording

mechanical and mechatronic master key systems.

Advantages:

Convenient master key system data input with “kwd” fi le

Confi guring and administering master key systems with a single

software

Modern screen display presenting a convenient confi guration

and key combination chart

Service email:

[email protected]

Page 125: Smok & Heat

125Edition 12.2009

Software and Service

Ordering software

CIS – Customer Information System

Ordering and customer information system comprising all articles

with specifi ed article number.

Advantages:

Permanent article data upgrade

Illustrated articles

Provision of stock information

Convenient dispatch of orders with import function

(e.g., *.csv fi les)

Service email:

[email protected]

ObS – Order by Scanning

Barcode scanner ordering system for production, store and/or

administration to ascertain material requirements.

Advantages:

Reduced material planning effort

Plausibility check tool eliminates errors

Reduced sourcing times

Service email:

[email protected]

MKS – MasterKeySystem

Web-based tool for planning and ordering master key systems.

Advantages:

Permanent article data upgrade

Plausibility check tool eliminates errors

Maximum availability of information data related to existing

master key systems

Master key system data for BKS KeyManager 3.0 or higher

Free retrieval of key combination records

Service email:

[email protected]

Page 126: Smok & Heat

126 Edition 12.2009

Software and Service

Customised solutions

Hardware data service

Creation of individual hardware solutions and provision of CNC data

for automated window fabrication.

Advantages:

Generation of individual hardware data for the market-leading

window fabrication software programmes

Provision of CNC data for the control of production procedures

in window and door fabrication

Up-to-date article data base containing single items and hard-

ware sets

Service email:

[email protected]

Electronic connection to the customer’s merchandise management system

Optimised interfaces allowing for effi cient order processing with the

customer’s material management system.

Advantages:

Complete handling of the digital value-added chain from order

through to invoice

Just-in-time delivery rather than overstocked material stores

Perfected ordering system with the benefi t of error elimination

thanks to the customer’s material management system being

integrated into the ordering procedure around the clock

Service email:

[email protected]

Page 127: Smok & Heat
Page 128: Smok & Heat

WP00009-04-1-1 – 12/2009 – Printed in Germany

BKS GmbHHeidestr. 71D-42549 VelbertPhone + 49 (0) 20 51 2 01-0Fax + 49 (0) 20 51 2 01-4 31

Gretsch-Unitas GmbHBaubeschlägeJohann-Maus-Str. 3D-71254 DitzingenPhone + 49 (0) 71 56 3 01-0Fax + 49 (0) 71 56 3 01-2 93

www.g-u.com