Smarter, Greener Learning: Findings from the SusteIT Project

20
BENEFITTING FROM GREEN IT FINDINGS FROM THE SUSTEIT PROJECT Professor Peter James www.susteit.org.uk

description

Presentation by Professor Peter James for JISC RSC London's Smarter Greener Learning event held at City Hall, London, 26/02/09

Transcript of Smarter, Greener Learning: Findings from the SusteIT Project

Page 1: Smarter, Greener Learning: Findings from the SusteIT Project

BENEFITTINGFROM GREEN IT

– FINDINGS FROM THESUSTEIT PROJECT

Professor Peter Jameswww.susteit.org.uk

Page 2: Smarter, Greener Learning: Findings from the SusteIT Project

THE CASE FOR CHANGE• Sticks

- Energy and other costs- Regulations

• Carrots- financial and operational benefits- teaching and research

• Reputation

• Stakeholder requirements

Page 3: Smarter, Greener Learning: Findings from the SusteIT Project

ICT BENEFITS – SMART 2020• Environmental

- Cut global CO2 emissions in 2020 by 15%, with $946 billion of cost savings- Avoid c 5 tonnes of CO2 emissions through applications for every tonne created by production, use & disposal of equipment

• Social- e.g. access; overcoming disability

Page 4: Smarter, Greener Learning: Findings from the SusteIT Project

4

AVE MARIA UNIVERSITY

IntrusionDetection

Fire AlarmSystemPower System

ElevatorMgmt.

LightingControls

HVACControl

EvacuationManagement

SecurityUsers

BuildingMaintenance Users

Access Control(security system)

CampusSecurity

Page 5: Smarter, Greener Learning: Findings from the SusteIT Project

ENERGY & CARBON FOOTPRINT

• Downloadable tool – www.susteit.org.uk

• Default assumptions … or your own data

• University of Sheffield- 19% of non-domestic electricity- £1 million + bills in 2009- PCs higher than expected- Data centres/networks lower than expected

Page 6: Smarter, Greener Learning: Findings from the SusteIT Project

FOOTPRINTING RESULTSUniversity of Sheffield

University of Sheffield (ex HPC)

Lowestoft College

City College Norwich

Total Electricity (kWh)

8,680,806 (100%) 7,472,188 (100%) 453,714 (100%) 1,241,700 (100%)

PCs and monitors

4,164,477 (48%) 4,164,477 (56%) 197,402 (44%) 510,896 (41%)

Servers 1,520,736 (18%) 1,520,736 (20%) 135,999 (30%) 226,665 (18%)

HPC 1,208,617 (14%) 0 0 0

Imaging 835,659 (10%) 835,659 (11%) 42,171 (9%) 236,901 (19%)

Networks 687,362 (8%) 687,362 (9%) 68,538 (15%) 156,629 (13%)

AV/Telephony 3% 4% 3% 8%

Page 7: Smarter, Greener Learning: Findings from the SusteIT Project

A LARGE ICT FOOTPRINT

• 2% of global CO2 emissions

• ICT in UK FE 2008- 708,000 PCs- 23,000 servers- 98,000 networked printers- £54m electricity bill- £12 per student- 244,000t of carbon dioxide

Page 8: Smarter, Greener Learning: Findings from the SusteIT Project

325,000 Coal-Powered Computers

Page 9: Smarter, Greener Learning: Findings from the SusteIT Project

A LARGE FOOTPRINT

Materials

Manufacture

Transport

UseDisposal

Page 10: Smarter, Greener Learning: Findings from the SusteIT Project

KEY LIFE CYCLE QUESTIONS• Can we ever get a complete picture?

- HP 1.5 million tonnes CO2 eq direct- 4.5 million tonnes from Tier 1 suppliers

• What balance of impacts across the life cycle? e.g. production:use energy - Williams/UN University 4:1- EU Commission study 1:4

• How can we influence upstream impacts?

Page 11: Smarter, Greener Learning: Findings from the SusteIT Project

DATA CENTRE END USE

Server Load/ComputingOperations

Cooling Equipment

Power Conversions

& Distribution100

Units

33 UnitsDelivered

35 Units

Source: US EPA

Page 12: Smarter, Greener Learning: Findings from the SusteIT Project

CARDIFF UNIVERSITY

• Low power servers

• Chilled water cooling

• Efficient layout

• Efficient UPS

• 30% support overhead

Page 13: Smarter, Greener Learning: Findings from the SusteIT Project

ACTION PLAN - MANAGEMENT• Calculate energy consumption

- formulate action plan and targets

• Set up a cross-functional team

• Calculate total cost of ownership- energy prices; refresh cycles; support costs

• Energy-related financial incentives for IT- paying energy bills for server rooms?

Page 14: Smarter, Greener Learning: Findings from the SusteIT Project

ACTION PLAN - DESKTOP• Power down computers when not in use

- network software; PC settings

• Ensure all non-managed computers are powered down when not in use

• Make 5 year refresh cycles the norm- justify exceptions by evidence and sign off

• Specify Energy Star 4 (soon 5) for all purchases

• Dispose of old equipment responsibly

Page 15: Smarter, Greener Learning: Findings from the SusteIT Project

ACTION PLAN - PRINTING• Audit paper consumption

- set targets- measure/monitor consumption

• Power down printers outside office hours

• Encourage paper-efficient printing- draft mode- double sided

Page 16: Smarter, Greener Learning: Findings from the SusteIT Project

ACTION PLAN - INFRASTRUCTURE• Follow the EU Code of Conduct for all

significant data centre investment

• Take simple measures to minimise cold/air mixing in server rooms- e.g. containment; blanking plates

• Consolidate servers- switch off unused ones

Page 17: Smarter, Greener Learning: Findings from the SusteIT Project

MEDIUM TERM MEASURES• Metering/monitoring key areas of consumption

• Full implementation of EU Code of Conduct- power supply; virtualisation; free cooling

• Maximum use of thin client where effective

• Effective document and print management

• Minimising storage

• Increasing videoconferencing

• Flexible working

Page 18: Smarter, Greener Learning: Findings from the SusteIT Project

QUEEN MARGARET UNIVERSITY

• Wanted greenest building in UK

• PCs main barrier

• 98% thin client

• 25-30% space savings

Page 19: Smarter, Greener Learning: Findings from the SusteIT Project

THE FUTURE• Less energy and material intensive desktops

- cloud computing- medium client- e-readers and ‘total content’

• Zero carbon data centres

• Pay as you go computing

• Intelligent campus- from computer to building maintenance?

Page 20: Smarter, Greener Learning: Findings from the SusteIT Project

Server Load/ComputingOperations

Cooling Equipment

Power Conversion & Distribution

AlternativeEnergy Supply

High voltage distributionUse of DC powerHighly efficient UPS systemsEfficient redundancy strategies

Power efficiency & managementLoad managementConsolidation/Virtualisation

Better air managementFree/efficient coolingEfficient liquid coolingFlexibility and control

On-site renewablesWaste heat for coolingFuel cellsThermal storage

ENERGY EFFICIENCY MEASURESAdapted from US EPA original