SM0352 V-9-D Vibrator 091114 - Syntron Material …...1 Service Instructions Syntron Vibrator Model:...
Transcript of SM0352 V-9-D Vibrator 091114 - Syntron Material …...1 Service Instructions Syntron Vibrator Model:...
Service Instructions V-9-D Vibrator
1
Service Instructions
Syntron Vibrator Model: V-9-D
Syntron Material Handling reserves the right to make changes at any time, without any liability or other
obligation on its part, in materials, equipment, specifications and models, and also to discontinue the manufacture
and sale of models, and the parts and components thereof. For further detailed information contact, Syntron
Material Handling LLC, Saltillo, MS 38866 (662) -869-5711
Safety Instructions: Product safety labels must remain highly visible on the equipment. Establish a regular
schedule to check visibility. Should safety labels require replacement contact Syntron Material Handling
LLC for an additional supply free of charge.
INTRODUCTION
The Syntron Electromechanical Vibrator, Model V-9-D produces a pattern of vibrations which penetrate a
material mass, keeping the particles agitated and in a free flowing condition.
The vibrator is operated from an A-C power supply using a standard controller.
A controller, required for RC operation, uses a rectifier to block the bottom portion of the sine wave producing a
pulsating pattern of electrical current. The action of the vibrator operating from a half cycle of power, is
transmitted through the springs to the equipment to be vibrated.
The “S” Model vibrator has a built-in rectifier, which eliminates the need of a controller. However, the vibrator output remains constant. The “S” Model vibrator is connected directly to the power supply.
INSTALLATION
The vibrator may be installed in any position, on a vertical plane.
The base is provided with 7/16” diameter mounting holes. The bolts must be securely tightened; check frequently
to see that these bolts remain tight.
The current supply must be the same as the rating designated on the nameplate.
OPERATION
NOTE: If the vibrator is installed on a hopper, do not operate the vibrator while the hopper is closed, the
vibratory action will compact the contents of the hopper.
To operate the vibrator, simply connect leads to the control terminals and control to the power supply. The use of
a controller permits the output of the vibrator to be controlled by turning the rheostat knob; clockwise to increase
output and counterclockwise to decrease output.
2
CAUTION: If the current draw is excessive, the armature and the core assemblies begin to strike;
indicated by a loud rapping noise. Immediately decrease the rheostat setting until the striking stops,
indicated by the diminishing noise. Refer to “Air Gap Adjustment” instructions to correct striking condition.
MAINTENANCE
WARNING: Disconnect the power supply at the safety disconnect switch before performing any
maintenance.
Vibrator and controller must be kept clean and all hardware must be kept tight.
Examine rubber components for cracks or loss of resiliency. If defective, replace all mounting assemblies. After
replacing mounting assemblies, check the air gap, an adjustment may be required. Refer to “Air Gap Adjustment”
section of these instructions.
AIR GAP ADJUSTMENT
The air gap is the space between the core and armature assemblies. If the armature assembly strikes the core
assembly (indicated by a loud rapping noise) an adjustment of the air gap is necessary.
The air gap should be set wide enough so the vibrator will not exceed the current rating designated on the name
plate yet close enough to prevent striking of the armature and assemblies. The air gap must be set at
approximately .160” for 60 cycle units and .175 for 50 cycle units. To check the air gap, remove the cover from
the body assembly and insert a feeler gauge. Adjustment is determined by the number and size of shims (J)
between the rubber mounting and armature bracket.
TROUBLE SHOOTING
Problem Cause Correction
Vibrator operates
Below capacity
Loose hardware
Defective magnet
Defective rubber mounts
Repair
*Replace
*Replace
Vibrator does
Not run
Loose connections in controller
Defective rheostat
Repair
*Replace
* Replace parts only with those supplied or recommended by SYNTRON.
3
ITEM DECRIPTION QTY PART NO
A Cover 1 C-56623-3
*Nameplate (115V/60HZ) 1 A-61712-3
*Nameplate (115V/60HZ) ONLY A-61712
(230V/50-60HZ)
Mach. Screw, Fil. Hd. 2 H0208701
(1/4-20 x 3/4”)
Lock Washer (1/4”) 2 H0112858
*SYNTRON Decal 1 A-156379-A1
*Label (Disc. Elec.) 1 A-125694
B Armature Assembly 1 B-11825
C Armature Adj. Shim (1/32” Tk) As A-11903-A
Armature Adj. Shim (1/64” Tk) Req’d. A-11903-B
Armature Adj. Shim (.005” Tk) A-11903-C
D Cap Screw Hex Hd. 2 H0310201
(3/8”-16 x 1”)
Lock Washer (3/8”) 2 H0113201
Hex Nut (3/8”-16) 2 H0103001
E Cap Screw, Hex Hd. 4 H0301601
(1/4”-20 x 1”)
Lock Washer (1/4”) 4 H0114904
F Armature Mounting Rubber 2 A-20903
(60HZ Units Only)
Armature Mounting Rubber 2 A-42258
(50HZ Units Only)
G Coil Assembly (115V/60HZ) C-195657-B
Coil Assembly (230V/60 HZ) 1 C-195657-C
Coil Assembly (115V/50HZ) Only C-195657-D
Coil Assembly (230V/50HZ) C-195657-E
*Rectifier Assembly (115V) 1 A-114601-AS
H Armature Mounting Spacer 4 A-22387
J Core Mounting Assembly 1 B-15208
K Cap Screw, Hex Hd. 2 H0302201
(1/4”-20 x 1 1/2”)
Lock Washer (1/4”) 2 H0114904
Plain Washer (1/4”) 2 H0116601
Jam Nut (1/4”-20) 2 H0101604
M Cable Assembly w/Grommet 1 C-160136-B
Cable Assembly w/o Grommet 1 C-160136-C
* Used on V-9-D(S) Units Only.
Corporate Office
P.O. Box 1370 Tupelo, Mississippi 38802
Phone: 662.869.5711 Fax: 662.869.7449
Tupelo 2730 Hwy 145 South Saltillo, Mississippi 38866 Phone: 662.869.5711 Fax: 662.869.7493 Toll Free: 800.356.4898 [email protected]
Salt Lake City 1525 S. 4710 W. Unit: E Salt Lake City, Utah 84104 Phone: 801.990.6323 Fax: 801.990.6324 Toll Free: 877.780.1227 [email protected]
Changshu #2 Road No. 1 Changshu Export Processing Zone Changshu, Jiangsu, China 215513 Phone: +86 0512.52299002 Fax: +86 0512.52297228 [email protected]
Form No. SM0352_091114 Printed in U.S.A