SLOPES IV Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon...

download SLOPES IV  Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering  Asset Management.

If you can't read please download the document

description

SLOPES III Total Scour Elevation Active Channel Width Total Scour Depth

Transcript of SLOPES IV Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon...

SLOPES IV Structure Span OHW ACW Functional Floodplain Span (FFS) Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management Unit Manager SLOPES IV Structure Span Bridges and Culverts Good Engineering Judgment Streamlined Permitting Option Early Evaluation & Communication SLOPES III Total Scour Elevation Active Channel Width Total Scour Depth BRIDGE SCOUR Total Scour at a Bridge Total Scour Elevation Total Scour Depth Functional Floodplain Span (FFS) Key Terms General Scour Depth ACW Bank Full Width Top of Bank General Scour Elevation OHW Thalweg Functional Floodplain Span Single Span Structure 1.5 x Active Channel Width Multi-Span Structure 2.2 x Active Channel Width General Scour Prism General Scour Depth OHW ACW Functional Floodplain Span (FFS) AB FFS = ACW + A + B General Scour Prism Functional Floodplain Span Single Span Structure FFS = 1.5 x ACW = ACW + A + B A+B = 0.5 x ACW Multi-Span Structure FFS = 2.2 x ACW = ACW + A + B A+B = 1.2 x ACW Bridge Abutment Protection Required Because: Abutment Scour not considered Channel Migration Foundation on Erodible Materials GEOENVIRONMENTAL/ ftp://ftp.odot.state.or.us/SLOPES_IV Paul R. Wirfs, P.E. Oregon Department of Transportation Engineering & Asset Management Unit Manager