www.prolight.co.uk Slimline 7HEX6 Series User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablevoltageisbetween100~240V,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• WARRANTY:Oneyearfromdateofpurchase.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

www.prolight.co.uk Slimline 7HEX6 Series User Manual 3

Product overview & technical specifications

Housing7x6Whex-colourLEDs,theSlimline7HEX6givessmoothcolourmixingfromrichsaturatedhuestosubtlepastelshades.Theseunitshaverugged,allmetalhousingandmeasureonly124mmindepthforeasytransportationandinstallation.Theyarealsoconvectioncooledforsilentoperationandfeaturea30°beamangle.The4pushbuttonLEDmenuoroptionalIRremotealloweasyaccesstothefunctionsincludingDMX,master/slave,soundactiveandstandalone.

•7x6W6-in-1colourLEDs(RGBAWUV)

•Beamangle:30°(fieldangle:40°)

•400Hzrefreshrate

•DMXchannels:2/3/3/4/4/5/6or9selectable

•Staticcolour,colourchange,colourfade,auto,soundactiveandmaster/slavemodes

•0-100%dimmingandvariablestrobe

•Remotedevicemanagement(RDM)

•Bracketallowsformultipleriggingorfloorstandingapplications

•Recessedrearcontrolpanelandrubberfeetallowthepaneltositflatonthefloorforuplighting

•4pushbuttonmenuwithLEDdisplay

•IECpowerin/outsockets

•3-pinXLRin/outsockets

•SideentryXLRandpowerconnections

•Convectioncooled

•OptionalIRremote(LEDJ90F)

Slimline 7HEX6 Series

Specifications Slimline 7HEX6

Powerconsumption 50W

Powersupply 100~240V,50/60Hz

Dimensions 212x124x222mm

Weight 2.0kg

Ordercode LEDJ60-Blackhousing

Ordercode LEDJ60A-Whitehousing0m 1m 2m 3m 4m 5m

30° - Lux 5180 1483 664

30°

343 220

212mm 124mm

222mm

www.prolight.co.uk Slimline 7HEX6 Series User Manual 4

Technical specifications

01-Bracket

02-Brackettighteningknobs

03-Earthpoint

04-LEDdisplay

05-Functionbuttons

06-DMXinputsocket

07-DMXoutputsocket

08-IECpowerinsocket

09-IECpoweroutsocket

10-Fuse1A250V Inthebox:1 x fixture, 1 x power cable & 1 x user manual

0810 0903 07 06

SLIMLINE 7HEX6

POWER IN

www.prolight.co.uk

MODE ENTER UP DOWN

POWER OUT DMX OUT DMX IN

02

04

05

01

PUSH

www.prolight.co.uk Slimline 7HEX6 Series User Manual 5

Operating instructions

DMX channel mode:

OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.

ToaccesstheDMXchannelmode,pressthe“MODE”buttonontherearoftheunittoshowA001ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthedesiredDMXaddress.Nowpressthe“ENTER”buttontochooseoneofthe2,3,3,4,4,5,6or9DMXchannelmodesusethe“UP”and“DOWN”buttons,andpressthe“ENTER”buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2000-255colourmacro

000-016 Red

017-033 Green

034-050 Blue

051-067 White

068-084 Amber

085-101 UV

102-118 Yellow(R-255,G-200,A-255)

119-135 Cyan(G-255,B-255)

136-152 Lavender(R-170,B-210)

153-169 Brightgreen(G-255,A-180)

170-186 Magenta(R-255,B-90,UV-255)

187-203 Turquoise(G-255,B-180,UV-255)

204-220 Orange(R-200,A-200)

221-237 Coolwhite(R-70,G-190,B-255,A-200)

238-255 Warmwhite(R-230,G-255,B-255,A-255,W-255)

2 channel mode:

www.prolight.co.uk Slimline 7HEX6 Series User Manual 6

Operating instructions

Channel Value Function

1 000-255 Red(0-100%)

2 000-255 Green(0-100%)

3 000-255 Blue(0-100%)

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2 000-255 Flash(speed0-100%,1Hz-20Hz)

3 000-004 Blackout

005-010 Red

011-015 Green

016-020 Blue

021-025 White

026-030 Amber

031-035 UV

036-040 Yellow(R-255,G-200,A-255)

041-045 Cyan(G-255,B-255)

046-050 Lavender(R-170,B-210)

051-055 Brightgreen(G-255,A-180)

056-060 Magenta(R-255,B-90,UV-255)

061-065 Turquoise(G-255,B-180,UV-255)

066-070 Orange(R-200,A-200)

071-075 Coolwhite(R-70,G-190,B-255,A-200)

076-080 Warmwhite(R-230,G-255,B-255,A-255,W-255)

081-150 ColourjumpingspeedSlowest(081)changesevery8secsFastest(150)changesevery0.3secs

151-220 ColourfadingspeedSlowest(151)changesevery8secsFastest(220)changesevery0.3secs

221-255 Soundcontrol(micsensitivity)

3 channel mode:

3 channel mode:

Channel Value Function

1 000-255 Red(0-100%)

2 000-255 Green(0-100%)

3 000-255 Blue(0-100%)

4 000-255 White(0-100%)

Channel Value Function

1 000-255 Red(0-100%)

2 000-255 Green(0-100%)

3 000-255 Blue(0-100%)

4 000-255 Amber(0-100%)

Channel Value Function

1 000-255 Red(0-100%)

2 000-255 Green(0-100%)

3 000-255 Blue(0-100%)

4 000-255 White(0-100%)

5 000-255 Amber(0-100%)

Channel Value Function

1 000-255 Red(0-100%)

2 000-255 Green(0-100%)

3 000-255 Blue(0-100%)

4 000-255 White(0-100%)

5 000-255 Amber(0-100%)

6 000-255 UV(0-100%)

4 channel mode: 4 channel mode:

5 channel mode: 6 channel mode:

www.prolight.co.uk Slimline 7HEX6 Series User Manual 7

Operating instructions

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2 000-255 Flash(speed0-100%,1Hz-20Hz)

3 000-255 Red(0-100%)

4 000-255 Green(0-100%)

5 000-255 Blue(0-100%)

6 000-255 White(0-100%)

7 000-255 Amber(0-100%)

8 000-255 UV(0-100%)

9 000-004 Blackout

005-010 Red

011-015 Green

016-020 Blue

021-025 White

026-030 Amber

031-035 UV

036-040 Yellow(R-255,G-200,A-255)

041-045 Cyan(G-255,B-255)

046-050 Lavender(R-170,B-210)

051-055 Brightgreen(G-255,A-180)

056-060 Magenta(R-255,B-90,UV-255)

061-065 Turquoise(G-255,B-180,UV-255)

066-070 Orange(R-200,A-200)

071-075 Coolwhite(R-70,G-190,B-255,A-200)

076-080 Warmwhite(R-230,G-255,B-255,A-255,W-255)

081-150 ColourjumpingspeedSlowest(081)changesevery8secsFastest(150)changesevery0.3secs

151-220 ColourfadingspeedSlowest(151)changesevery8secsFastest(220)changesevery0.3secs

221-255 Soundcontrol(micsensitivity)

9 channel mode:

www.prolight.co.uk Slimline 7HEX6 Series User Manual 8

RGBAWUV colour mix mode:

Inthismodeyoucansetthefixturetoanycolourandanybrightness.

Toaccessthecolourmixmode,pressthe“MODE”buttonontherearoftheunittoshow C1--with3digitsafterontheLEDdisplay.Pressthe“ENTER”buttontoconfirm.

TheC1representsred,C2=green,C3=blue,C4=white,C5=amber,C6=UVandCF0=strobe.The2digitsafterarethebrightnesssettingfrom 00~99,orthestrobespeedifinCF0.

For example: Ifyouset1,2,3,4,5and6alltozero,yourunitwillhavenoLEDslitup(blackout).IfyousetC100toC199and2,3,4,5and6tozero,yourunitwillshowonlyredLEDs.

Pressthe“ENTER”buttontoconfirmthesettingandmovetothenextcolour.Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Colour fade mode:

Toaccessthecolourfademodepress“ENTER”untilthedisplayshowsFA--ontheLEDdisplay.Toadjustthespeedusethe“UP”and“DOWN”buttonstoselectanyvaluefromFA00~FA99.Toselectthestrobemodepress“ENTER”,theLEDdisplaywillchangetoFF--,usingthe“UP”and“DOWN”buttonstoselectanyvaluefromFF00~FF99.

Value: 00 - 99 (00 = low, 99 = high)

Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Colour change mode:

Toaccessthecolourchangemodepress“ENTER”untilJU--showsontheLEDdisplay.Toadjustthespeedusethe“UP”and“DOWN”buttonstoselectanyvaluefromJA00~JA99.Toselectthestrobemodepress“ENTER”,thedisplaywillchangetoJF--,usingthe“UP”and“DOWN”buttonstoselectanyvaluefromJF00~JF99.

Value: 00 - 99 (00 = low, 99 = high)

Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Master/slave mode:

Tosetthemasterunit,pressthe“MODE”buttonontherearofthemasterunitthenselectyourdesiredprogram(soundactive,auto,staticcolour,colourmixoroneofthebuilt-inprograms).Tosettheotherunitsinslavemode,pressthe“MODE”buttonontherearoftheunittoshowSLAUontheLEDdisplayandpressthe“ENTER”buttontoconfirmthesetting.Theunitwillnowruninsequencewiththemasterunit.

Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.

Operating instructions

www.prolight.co.uk Slimline 7HEX6 Series User Manual 9

Sound active mode:

Toaccessthesoundactivemode,pressthe“MODE”buttonontherearoftheunittoshowSU00ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthesoundsensitivitylevelfromSU.00~SU.99andpressthe“ENTER”buttontoconfirmthesetting.

Value: 00 - 99 (00 = low, 99 = high)

Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Auto run mode:

Toaccesstheautorunmode,pressthe“MODE”buttontoshowAUtOontheLEDdisplay.Thefixturewillthenautomaticallyscrollthroughcolourfadeandcolourchange.Thespeed/flashrateisnotadjustable.

Pressthe“ENTER”buttontoconfirmthesetting.Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Colour preset mode:

Toaccessthecolourpresetmodepress“ENTER”untilCn--showsontheLEDdisplay.Toadjustthecolourusethe“UP”and“DOWN”buttonstoselectanyvaluefromCn01~Cn15.

Pressthe“ENTER”buttontoconfirmthesetting.Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Operating instructions

Staticcolourmode C1.00~C1.99RC2.00~C2.99GC3.00~C3.99BC4.00~C4.99WC5.00~C5.99AC6.00~C6.99UCF.00~CF.99Flash

ColourmacromodeCn01-15

Cn01-RedCn02-GreenCn03-BlueCn04-WhiteCn05-AmberCn06-UVCn07-YellowCn08-LightblueCn09-PinkCn10-LightgreenCn11-RosepinkCn12-PeacockblueCn13-OrangeCn14-Pastelblue/whiteCn15-White

Colourchangingmode JU00~JU99(speed)JF00~JF99(flash)

Colourdreamingmode(Fade) FA00~FA99(speed)FF00~FF99(flash)

Automode AUTO

Slavemode SLAV

Soundactivemode SU00~SU99

DMXmode 2CH,3CH1,3CH2,6CH,9CH

Addresssetting A001~A512

Menusystem

www.prolight.co.uk Slimline 7HEX6 Series User Manual 10

Operating instructions

Optional IR remote functions:

Button functions:

DMX address examples:

Important notes:

•SettheDMXaddressoneachfixturebeforepluggingintotheDMXcontroller

•TheIRremoteiscannotbeusedwhenthefixture(s)arebeingcontrolledbyaDMXcontroller

•Themaximumtransmitterdistanceis10m-PleasemakesurethatyouhavetheIRremoteaimeddirectlyatthefrontpanelofeachfixturetobeprogrammed

• Ifyoudonotpressthe“DMXMODE”buttonafteryouhavechangedtheDMXaddress,whenyoupowerdownthefixtureitwilllosetheaddressyouhaveset

01-SettheLEDsintopoweronoroffmodes

02-Setinautorun

03-Runthebuilt-inprograms,thenusethe‘+’and‘-’buttonstogothroughtheprograms

04-SettheLEDstoflashonandoff,thenusethe‘+’and‘-’buttonstochangetheflashfrequency

05-Settherunspeed,thenusethe‘+’and‘-’buttonstochangethedesiredspeed(note:onlyavailableinthecolourchangeorcolourfademodes)

06-SettheLEDsintoDMXmode

07-SettheLEDsintosoundactivemode

08-SettheLEDsintoslavemode

09-SettheDMXaddressfortheLEDs

10-SettheLEDscolour,thenusethe‘+’and‘-’buttonstochangethebrightness

1 2 34 5 6 0

+

_7 8 9

AR

D

FL

SL

SP

S

S PR

SA

R G B

W A UV

BLACKOUT DIMMING

FLASH

SLAVE

SPEED

SET ADDR

SELECT PROG

SOUND ACTIVE

AUTO RUN

DMX MODE

03

01

04

10

02 05

07 08

06 09

TosettheDMXaddress“245”;

•Pressthe“S”button,theredLEDswillcomeon,youcannowstarttosettheDMXaddress

•Nowpressthe“2”button,thegreenLEDswillcomeon,thismeansthefirstdigithasbeensetat2

• Nowpressthe“4”button,theblueLEDswillcomeon,thismeanstheseconddigithasbeensetat4

• Nowpressthe“5”button,andalloftheR,G,B,A,WandUVLEDswillcomeon,thethirddigit5hasbeenset.ThefullDMXaddresssettinghasbeenchanged

•Nowpressthe“DMXMODE”buttontosavethenewaddressintothememory

TosettheDMXaddress“002”;•Pressthe“S”button,theredLEDswillcomeon,youcannowstarttosettheDMXaddress

•Nowpressthe“0”button,thegreenLEDswillcomeon,thismeansthefirstdigithasbeensetat0

• Nowpressthe“0”button,theblueLEDswillcomeon,thismeanstheseconddigithasbeensetat0

•Nowpressthe“2”button,andalloftheR,G,B,A,WandUVLEDswillcomeon,thethirddigit2hasbeenset.ThefullDMXaddresssettinghasbeenchanged

• Nowpressthe“DMXMODE”buttontosavethenewaddressintomemory

Optional IR remote Order code: LEDJ90F

www.prolight.co.uk Slimline 7HEX6 Series User Manual 11

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-511.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

www.prolight.co.uk Slimline 7HEX6 Series User Manual 12

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Terminationreducessignaltransmissionproblemsandinterferance.itisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

www.prolight.co.uk Slimline 7HEX6 Series User Manual 13

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk Slimline 7HEX6 Series User Manual 14

Optional accessories

Pleasecontactyourlocalretailertopurchasetheseaccessories.

Tokeepup-to-dateonthelatestaccessoriesandproductrangeadditionspleasevisitwww.prolight.co.uk

Optional Quad Case (Holds 4 x fixtures)Order code: CASE95

Optional IR remoteOrder code: LEDJ90F

1 2 34 5 6 0

+

_7 8 9

AR

D

FL

SL

SP

S

S PR

SA

R G B

W A UV

BLACKOUT DIMMING

FLASH

SLAVE

SPEED

SET ADDR

SELECT PROG

SOUND ACTIVE

AUTO RUN

DMX MODE

www.prolight.co.uk Slimline 7HEX6 Series User Manual 15

www.prolight.co.uk Slimline 7HEX6 Series User Manual 16