slide rule
-
Upload
marimuthu-ayyamperumal -
Category
Documents
-
view
26 -
download
3
description
Transcript of slide rule
![Page 1: slide rule](https://reader030.fdocuments.in/reader030/viewer/2022020217/552d90fd4a795915608b4717/html5/thumbnails/1.jpg)
Spa House, Hookstone ParkHarrogate, North Yorkshire, HG2 7DB
Tel: 01423 889845 Fax: 01423 880724
EMFLEXExpansion Joint
Calculator
Instruction to calculate amount of thermal expansion
Firstly align the central white sliding scale showing the PIPE LENGTH with the CARBON STEEL or COPPER arrow.Secondly look at the TEMPERATURE DIFFERENCE blue scale.Finally read of the EXPANSION from the central white sliding scale.
Example 1:
Consider a carbon steel pipe of 30 metres length, which expands when the temperature rises from 0 to 80 deg C.
TEMPERATURE DIFFERENCE = 80 - 0 = 80 deg C.
Therefore by aligning the scales, EXPANSION = 30 mm.
Example 2:
Consider a copper pipe of 15 metres length, which expands when the temperature rises from 0 to 70 deg C.
TEMPERATURE DIFFERENCE = 70 deg C.
Therefore by aligning the scales, EXPANSION = 17.5 mm.
Comparison Scales
Temperature comparison scales can be used to convert between degrees C and degrees F.
Pressure comparison scales can be used to convert between
EX
PA
NS
ION
JO
INT
C
AL
CU
LA
TO
R
EM
FL
EX
FL
EX
IBL
E C
ON
NE
CT
OR
S &
E
XP
AN
SIO
N JO
INT
S
N.M
inik
in &
S
on
s L
td.
Sp
a H
ou
se
, H
oo
ksto
ne
P
ark
, H
arr
og
ate
, H
G2
7
DB
.
Te
l: 0
14
23
8
89
84
5 F
ax:
01
42
3 8
80
72
4
CO
MP
AR
ISO
N S
CA
LE
S0
30
40
50
60
02
46
02
04
06
08
0
20
02
0C F ba
rp
si
o o
PIP
E A
LIG
NM
EN
T G
UID
ES
Th
e fir
st p
ipe
a
lign
me
nt
gu
ide
sh
ou
ld n
ot
be
m
ore
th
an
4
p
ipe
d
iam
ete
rs o
r 3
00
mm
fro
m th
e e
xpa
nsi
on
jo
int
an
d th
e se
con
d g
uid
e n
ot
mo
re th
an
1
4 d
iam
ete
rs fr
om
th
e fir
st.
PIP
E L
EN
GT
H m
etr
es
EX
PA
NS
ION
m
m
TE
MP
ER
AT
UR
ED
IFF
ER
EN
CE
C
TE
MP
ER
AT
UR
ED
IFF
ER
EN
CE
C
o
PIP
E L
EN
GT
H m
etr
es
EX
PA
NS
ION
m
m3
00
20
01
50
10
02
03
04
05
06
08
01
51
09
87
65
43
70
06
00
50
04
00
40
0
30
02
00
15
01
00
80
60
50
40
30
20
15
10
98
76
5
20
01
90
18
01
70
16
01
50
14
01
30
12
011
01
00
90
80
70
60
50
40
30
20
10
0m
m
CO
PP
ER
CA
RB
ON
S
TE
EL
N. MINIKIN & SONS LTD
![Page 2: slide rule](https://reader030.fdocuments.in/reader030/viewer/2022020217/552d90fd4a795915608b4717/html5/thumbnails/2.jpg)
offer the engineer:
* Design Book* Product Catalogue* Specification Guide
* Installation Instructions* Technical Advice
* Quality Assurance
EMFLEXExpansion Joint
Calculator
N. MINIKIN & SONS LTD
Instruction to calculate anchor force for axial expansion joints
Firstly align the central white sliding scale showing the WORKING PRESSURE with the relevent system working pressure.Secondly look at the relevent PIPE SIZE on the blue scale.Finally read of the FORCE from the central white sliding scale.
Example 1:
Consider a 50mm nominal size axial unit at 4 bar working pressure.
FORCE = 7.9kN
Example 2:
Consider a 200mm nominal size axial unit at 10 bar working pressure.
FORCE = 85.3kN
Scale Rules
Rules are provided at scales of 1:20, 1:50, 1:100 and 1:200 which are commonly used.
2.9
3.3
4.0
2 7.2
9.5
16
.3
20
.8
30
.8
37
.0
50
.1
65
.82
50
mm
20
0m
m
15
0m
m
12
5m
m
10
0m
m
80
mm
65
mm
50
mm
40
mm
32
mm
25
mm
WO
RK
ING
P
RE
SS
UR
Eb
ar
Th
e fig
ure
s in
th
e w
ind
ow
s sh
ow
th
e fo
rce
o
n th
e a
nch
ors
in
ki
lo-n
ew
ton
s fo
r w
ate
r a
t 8
0 C
in
clu
din
g fr
ictio
n o
f th
e g
uid
es.
20
m1
0m
40
m4
00
0m
m
19 38
38
00
18 9 36
36
00
17 34
34
00
16 8 32
32
00
15 30
30
00
14 7 28
28
00
13 26
26
00
12 6 24
24
00
11 22
22
00
10 5 20
20
00
9 18
18
00
8 4 16
16
00
7 14
14
00
6 3 12
12
00
5 10
10
00
4 2 88
00
3 66
00
2 1m 44
00
1m 2m
20
0m
m
1:1
00
0
1:5
0
0
1:2
00
0
1:2
0
0