SKYLITE V3.1 Internal · In order to function properly, SkyLite V3.1 must be connected to a...
Transcript of SKYLITE V3.1 Internal · In order to function properly, SkyLite V3.1 must be connected to a...
SKYLITE V3.1English
InternalInstallation Manual
PR161826 | Rev. H | 28/08/2019
PR161826 | Rev. H | Page 2 of 15
In order to function properly, SkyLite V3.1 must be connected to a dimmable driver/ballast.
NOTE: Some dimmable drivers/ballasts must be programmed/set to dimmable mode. If this has not been done, SkyLite V3.1 will not be able to dim the connected luminaire.
ATTENTION:
TVILIGHT BV / Rozenburglaan 3, 9727 DL Groningen, the Netherlands+31 (0)50 800 3240 / [email protected] / www.tvilight.com
PR161826 | Rev. H | Page 3 of 15
3. Factory Installation of SkyLite v3.1 into the Luminaire.............page 6
1. In Box........................................................................................................page 5
2. You Will Need........................................................................................page 5
4. Field Installation of a Luminaire with SkyLite v3.1...................page 13
5. Wiring Diagram...................................................................................page 16
When installing SkyLite v3.1 in a Luminaire.
What you will find in the Box.
Tools you will need for SkyLite v3.1 installation.
Installing a Luminaire with SkyLite v3.1.
Wiring diagram for connecting the SkyLite v3.1 to the Driver.
INDEX
PR161826 | Rev. H | Page 4 of 15
1. In Box
2. You Will Need
Screw Driver M3 Screw
Scan&Go App
Available in the Apple App Store
and in theGoogle Play Store
Drill
10.5 mmdrillbit
Pole Label
TVI-SKLMP-A031I-A01-002644
DEMODEMO
SkyLite V3.1
30
105
105
7.5
17 33.5 10.75 55
120
3.5
4.2
14
26
External Antenna
Nut
50 cm
Cable Assembly
29 cm
PR161826 | Rev. H | Page 5 of 15
3.1. Open Luminaire
3.2. Access Mounting Plate
3. Factory Installation of SkyLite v3.1 into the Luminaire
PR161826 | Rev. H | Page 6 of 15
3.3. Drill 10.5 mm hole in top of the Luminaire
3.4. Place Antenna through hole
Note: For added protection against rust, the use of an anti-corrosion spray such as WD40 Corrosion inhibitor or equal is recommended.
Remove adhesive backing prior to placement.
PR161826 | Rev. H | Page 7 of 15
3.5. Tighten Antenna using Antenna NutTighten the Antenna nut with a max. torque of 1.5 Nm.
3.6. Place SkyLite V3.1 on Mounting PlateScrew into place. ATTENTION: Observe precautions for the handling of electrostatic sensitive devices.
PR161826 | Rev. H | Page 8 of 15
3.8. Connect Antenna to SkyLite V3.1Tighten SMA connector with a torque of 0.8 Nm (finger tight). ATTENTION: Observe precautions for the handling of electrostatic sensitive devices.
3.7. Connect Cable AssemblyATTENTION: Observe precautions for the handling of electrostatic sensitive devices.
PR161826 | Rev. H | Page 9 of 15
3.9. Connect SkyLite v3.1 to DriverATTENTION: Observe precautions for the handling of electrostatic sensitive devices.
Note: Wiring Diagram can be found in Section 5.
After connecting SkyLite to Driver there is a risk of electric shock from the antenna connector. Do not touch while powered.
PR161826 | Rev. H | Page 10 of 15
3.10. Return Mounting Plate to closed position and close Luminaire
3.11. Attach the Pole Label to the Luminaire with a piece of tape
TVILIGHTwww.tvilight.comTVI-CSP1-01-0014
Note: This placement of the Pole Label is temporary until field installation of the Luminaire. The label should not be placed loose in the box and should not fall out or under the Luminaire when it is in the box.
PR161826 | Rev. H | Page 11 of 15
3.12. Put the Luminaire in the box for shipment
TVILIGHTwww.tvilight.comTVI-CSP1-01-0014
PR161826 | Rev. H | Page 12 of 15
4. Field Installation of the Luminaire4.1. You will find the Luminaire with Pole label
attached
4.2 Remove the sticker from the Luminaire and install the Luminaire onto the Pole
TVILIGHTwww.tvilight.comTVI-CSP1-01-0014
PR161826 | Rev. H | Page 13 of 15
4.3. Apply product ID sticker to the pole once the Luminaire is installed
SAMESTICKER
TVILIGHTwww.tvilight.com
TVI-CSP1-01-0014
TVILIGHTwww.tvilight.com
TVI-CSP1-01-0014
TV
ILIG
HT
ww
w.t
vilig
ht.c
om
TVI-C
SP1-
01-0
014
DEMODEMO
TVI-SKLMP-A031I-A01-002644
PR161826 | Rev. H | Page 14 of 15
www.tvilight.com
TVI-SKLEXT1-01-0014
www.tvilight.com
TVI-SKLMP-A031I-A01-002644
4.4 Add device to CityManager1. Download Tvilight Scan&Go from Apple iOS App Store or from Google Play
Store.
2. Login with your Username and Password.
3. Use the ‘Add device’ function in Scan&Go app to add the device to CityManager.
4. The location of the new device is determined by Scan&Go’s GPS and it will be indicated on the map.
5. The Device Serial Number will be added when scanning the QR-Code with the camera.
6. Fill in the required fields (the ones with an asterisk), select the device type and also select the type of ballast (PWM or DALI-Logarithmic or DALI-Linear).
Note: The type of ballast must be known before installation.
7. Press save and move to next device.
For more information on how to use Scan&Go app, please visit:
https://www.tvilight.com/scan-go/
PR161826 | Rev. H | Page 15 of 15
5. Wiring Diagram
GREY
0-10V-or
DALI-
BLUE
N
BROWN
L
GREEN
GND
BLACK
0-10V+or
DALI+
To Armature
To Mains
TVILIGHTSKYLITE V3.1
GND N L
Driver
GND N L
0-10V-or
DALI-
0-10V+or
DALI+0-10V-
orDALI-
0-10V+or
DALI+ N L
WARNING:
If not correctly connected product might not function or it might be permanently damaged.
Note: For added protection, an external circuit breaker at the power input of the product is recommended. Circuit breakers such as the ELeQ LS-94 5L2408 or similar rated products are acceptable.