Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated...

14
P.O. Box 1566, Coffs Harbour, NSW 2450 Ph: (02) 66529600 Fax: (02) 66529644 I/ We approve these drawings correct as Date: per contract. OVERHEAD ELECTRICITY POWER POLE PP 1 PHOTO LOCATION & DIRECTION LEGEND SEWER MAN HOLE GAS HYDRANT TELSTRA PIT WATERMAIN SEWERMAIN SEWER INSPECTION POINT SIP WATER METER RAIN WATER OUTLET TAP GRATED PIT GPIT RW WM BOUNDARY LINE TOP & TOE OF BANKS MAJOR CONTOUR LINE MINOR CONTOUR LINE TELSTRA LINE FENCE LINE TELSTRA PILLAR TPIL NOTE :- AUTHORITY. BEEN SURVEYED. 1. BOUNDARIES HAVE BEEN DETERMINED BY 2. SERVICES HAVE BEEN LOCATED ONLY WHERE VISIBLE, PRIOR TO EXCAVATION OR CONSTRUCTION ALL SERVICES ARE TO BE LOCATED BY RELEVANT PLAN DIMENSIONS ONLY, AND HAVE NOT 4. APPROXIMATE SITE AREA = 738.8m² 3. SPOT LEVELS AND CONTOURS SHOWN HEREON ARE FOR DESIGN PURPOSES ONLY AND ARE TO BE CONFIRMED ON SITE PRIOR TO EXCAVATION OR CONSTRUCTION . 5. DETAILS OF SURVEY ARE CORRECT TO THE DATE SHOWN 02/02/14 TR16034 = TR/HH/DD/S WHERE: HH = 16m (HEIGHT) S = 4m (SPREAD - RADIUS) DD = 0.3m (DIAMETER) TREE CODES 6. DBD UNAVAILABLE AT TIME OF SURVEY DUE TO UNREGISTERED PLAN ALL SERVICES ARE LOCATED BY SURFACE FEATURES ONLY (C) POSITIVE COVENANT 10.0m WIDE Issue Date Amendment Site survey MAITLAND C.C. NOTES: ORIGIN OF LEVELS - ASSUMED ------ CONTOUR INTERVAL 1.0m Electricity Telephone Road Kerb J/N Gas Flood Affected Footpath Drawn by Surveyor Client C.C. 5059 LOT Suburb Local Auth Water Par SERVICES Stormwater Sewerage UBD ref 5 UNDERGROUND -- BITUMEN ROLL CONTRETE Check with Council Checked Order No DATE C.S. 130107/100 09/02/2015 MAITLAND AVAILABLE AVAILABLE DP 1207153 Cnt Area on THORNTON 738.8m² NORTHUMBERLAND C. AVAILABLE STREET Surveying Planning Engineering ABN: 42 110 897 928 THE JUNCTION [email protected] (02) 4963 5521 (02) 4963 5520 E-mail: PO Box 853 Phone: Fax: NSW 2291 S O L U T I O N S pment Land Develo 1 09/20/15 INITIAL ISSUE KINGHAM CIRCUIT INTEGRITY PROJEX I PTY. LTD 2 22/09/15 ISSUE 2 - RETAINING & RAINWATER TANKS 935 925 3,600 6,000 3,000 6,020 5,098 10,215 9,035 8,965 RAINTANK ON CONC. PAD APPROX LOCATION RAINTANK ON CONC. PAD APPROX LOCATION EXISTING FENCE TO BE RETAINED GROUND MOUNTED CLOTHESLINE APPROX LOCATION FIELD GULLIES AS PER ENGINEERS DETAIL 600h MAXIMUM STACKER BLOCK RETAINING WALL WALL MOUNTED CLOTHESLINE APPROX LOCATION EXISTING TREES TO BE RETAINED AS PER COVENANT PROPOSED SUBDIVISION LINE DRIVE GRADIENT DRIVE GRADIENT SEWER MANHOLE LID TO BE REPLACED WITH HEAVY DUTY TYPE CAPABLE OF SUPPORTING VEHICLE LOADS 400h MAXIMUM STACKER BLOCK RETAINING WALL IF REQUIRED DISPLAY HOME FENCING PAIR OF UNEQUAL GATES 400h MAXIMUM STACKER BLOCK RETAINING WALL IN FRONT OF FENCE 400h MAXIMUM STACKER BLOCK RETAINING WALL IN FRONT OF FENCE SAW CUTS TO DRIVEWAY AS REQUIRED SAW CUTS TO DRIVEWAY AS REQUIRED RESIDENCE 1 APPROX PAD R.L 10.0 APPROX SLAB R.L 10.4 (SITE SCRAPE) RESIDENCE 2 APPROX PAD R.L 10.0 APPROX SLAB R.L 10.4 (SITE SCRAPE) 10.23 10.18 9.88 9.64 9.41 9.30 9.37 9.53 9.48 9.74 9.81 9.98 9.95 10.14 10.21 10.33 10.30 10.10 9.87 9.58 9.50 9.56 POWER 9.65 9.58 9.58 9.66 9.81 9.98 10.36 10.37 10.02 9.81 9.64 9.91 10.07 10.32 10.28 10.24 10.10 10.07 9.87 9.97 9.78 9.68 9.82 10.13 10.00 10 °05 '55 " 10°15'50" 100°15'50" 179 °26'30" 0.67 18.00 43.315 17.645 10.00 LP 9.61 R.L. 10.00 ASSUMED TOP OF KERB SITE B.M. WHITE ARC . 17 .755 R. 47.00 EDGE OF BITUMEN BACK OF KERB CROWN OF ROAD TR010101 TR010101 TR010101 TR010101 TR010101 LOT 5 DP 1207153 738.8m² LOT 4 6 G O V E R N M E N T R O A D K I N G H A M CIRCUIT (C) (C) (C) (C) N SMH 9.70 SMH SMH 10.12 WALL SETOUT LINE PARALLEL WALL SETOUT 100°15'50" 40.00 CONCRETE DRIVE & PATH WITH DRY SPRAY FINISH 32m 2 APPROX APPROX APPROX APPROX APPROX APPROX 5000L 5000L PAVERS 29m 2 APPROX CONCRETE DRIVE & PATH WITH DRY SPRAY FINISH 59m 2 APPROX WALL SETOUT LINE 2.5% fall 2.5% fall R.L 9.6 R.L 10.3 9% fall 2.5% fall 3.0% fall CUT FILL 9.50 RAMP DOWN 9.71 Site Plan Scale 1:200 BASIX NOTES : SITE AREA: 738.8m 2 TOTAL ROOF AREA: 372.9m 2 UNIT 1 : COND AREA: 127.34m 2 UN-COND AREA: 65.67m 2 LANDSCAPED AREA: 114.8m 2 CATCHMENT AREA: 200.8m 2 RAINTANK: 5000L CONNECTED TO TOILETS, EXTERNAL TAPS AND COLDWATER TAP TO WASHING MACHINE UNIT 2 : COND AREA: 140.82m 2 UN-COND AREA: 112.61m 2 LANDSCAPED AREA: 124.6m 2 CATCHMENT AREA: 172.1m 2 RAINTANK: 5000L CONNECTED TO TOILETS, EXTERNAL TAPS AND COLDWATER TAP TO WASHING MACHINE ALL TAPS TO BE 4 STAR RATED ALL TOILETS TO BE 3 STAR RATED CONSTRUCTION D.J.B NOTE: STORMWATER TO ENGINEER DETAIL & LANDSCAPING TO CONSULTANTS DETAIL R1 SITE: 360.6m2 R1: FOOTPRINT: 171.46m2 SITE COVERAGE: 47.5% R2 SITE: 378.2m2 R2: FOOTPRINT: 158.72m2 SITE COVERAGE: 42.0% NOTE: STORMWATER, WASTE WATER DISPOSAL & METER BOX LOCATIONS TO BE DETERMINED ON SITE. NOTE: ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS NOTE: DEVELOPMENT TO COMPLY WITH ACOUSTIC REPORT BY REVERB ACOUSTICS REF: 08-1226-R2 DATED: 02/11/13 NOTE: ENSURE SAWCUTS/KEY JOISTS TO DRIVEWAY AS REQUIRED

Transcript of Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated...

Page 1: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

P.O. Box 1566, Coffs Harbour, NSW 2450

Ph: (02) 66529600 Fax: (02) 66529644

I/ We approve these drawings correct as

Date:

per contract.

OVERHEAD ELECTRICITY

POWER POLEPP1 PHOTO LOCATION & DIRECTION

LEGEND

SEWER MAN HOLE

GASHYDRANT

TELSTRA PIT

WATERMAIN

SEWERMAIN SEWER INSPECTION POINTSIP

WATER METER

RAIN WATER OUTLET

TAP

GRATED PITGPIT

RW

WMBOUNDARY LINE

TOP & TOE OF BANKS

MAJOR CONTOUR LINE

MINOR CONTOUR LINE

TELSTRA LINE

FENCE LINE

TELSTRA PILLARTPIL

NOTE:-

AUTHORITY.

BEEN SURVEYED.

1. BOUNDARIES HAVE BEEN DETERMINED BY

2. SERVICES HAVE BEEN LOCATED ONLY WHERE VISIBLE, PRIOR TO EXCAVATION OR CONSTRUCTION ALL SERVICES ARE TO BE LOCATED BY RELEVANT

PLAN DIMENSIONS ONLY, AND HAVE NOT

4. APPROXIMATE SITE AREA = 738.8m²

3. SPOT LEVELS AND CONTOURS SHOWN HEREON ARE FOR DESIGN PURPOSES ONLY AND ARE TO BE CONFIRMED ON SITE PRIOR TO EXCAVATION OR CONSTRUCTION.

5. DETAILS OF SURVEY ARE CORRECT TO THE DATE SHOWN 02/02/14

TR16034 = TR/HH/DD/SWHERE:

HH = 16m (HEIGHT)

S = 4m (SPREAD - RADIUS)

DD = 0.3m (DIAMETER)TREE CODES

6. DBD UNAVAILABLE AT TIME OF SURVEY DUE TO UNREGISTERED PLAN ALL SERVICES ARE LOCATED BY SURFACE FEATURES ONLY

(C) POSITIVE COVENANT 10.0m WIDE

Issue Date Amendment

Site survey

MAITLAND

C.C.NOTES:

ORIGIN OF LEVELS - ASSUMED------

CONTOUR INTERVAL 1.0m

Electricity

Telephone

Road

Kerb

J/N

Gas

Flood Affected

Footpath

Drawn by

Surveyor

Client

C.C.

5059

LOT

Suburb

Local Auth

Water

Par

SERVICES

Stormwater

Sewerage

UBD ref

5

UNDERGROUND

--

BITUMEN

ROLL

CONTRETE

Check with Council

Checked

Order No

DATE

C.S.

130107/100

09/02/2015

MAITLAND

AVAILABLE

AVAILABLE

DP 1207153

Cnt

Area

on

THORNTON

738.8m²

NORTHUMBERLAND

C.

AVAILABLE

STREET

Surveying Planning Engineering

ABN: 42 110 897 928

THE JUNCTION

[email protected]

(02) 4963 5521(02) 4963 5520

E-mail:

PO Box 853

Phone: Fax:

NSW 2291

S O L U T I O N S

pmentLand Develo

1 09/20/15 INITIAL ISSUE

KINGHAM CIRCUIT

INTEGRITY PROJEX I PTY. LTD

2 22/09/15 ISSUE 2 - RETAINING & RAINWATER TANKS

935

925

3,6

00

6,000

3,0

00

6,020

5,098

10,215

9,0

35

8,9

65

RAINTANK ONCONC. PAD

APPROXLOCATION

RAINTANK ONCONC. PAD

APPROXLOCATION

EXISTINGFENCE TO BE

RETAINED

GROUND MOUNTED CLOTHESLINEAPPROX LOCATION

FIELD GULLIES AS PERENGINEERS DETAIL

600h MAXIMUM STACKERBLOCK RETAINING WALL

WALL MOUNTED CLOTHESLINEAPPROX LOCATION

EXISTING TREESTO BE RETAINED

AS PER COVENANT

PROPOSEDSUBDIVISION LINE

DRIVE GRADIENT

DRIVE GRADIENT

SEWER MANHOLE LID TO BE REPLACEDWITH HEAVY DUTY TYPE CAPABLE OF

SUPPORTING VEHICLE LOADS

400h MAXIMUM STACKERBLOCK RETAINING WALL

IF REQUIRED

DISPLAY HOMEFENCING

PAIR OFUNEQUAL

GATES

400h MAXIMUM STACKERBLOCK RETAINING WALL

IN FRONT OF FENCE

400h MAXIMUM STACKERBLOCK RETAINING WALL

IN FRONT OF FENCE

SAW CUTS TODRIVEWAY AS

REQUIRED

SAW CUTS TODRIVEWAY AS

REQUIRED

RESIDENCE 1APPROX PAD R.L 10.0

APPROX SLAB R.L 10.4(SITE SCRAPE)

RESIDENCE 2APPROX PAD R.L 10.0

APPROX SLAB R.L 10.4(SITE SCRAPE)

10.2

3

10.1

89.

88

9.64

9.41

9.30

9.37

9.53

9.48

9.74

9.81

9.98

9.95

10.1

4

10.2

1

10.3

3

10.3

0

10.1

09.

87

9.58

9.50

9.56

POWER9.65

9.58

9.58

9.66

9.81

9.98

10.3

6

10.3

710

.02

9.81

9.64

9.91

10.0

7

10.3

2

10.2

8

10.2

4

10.1

0

10.0

79.

87

9.97

9.78

9.68

9.82

10.1

3 10.0

0

10°0

5'5

5"

10°1

5'5

0"

100°15'50"

179°2

6'3

0"

0.6

7

18.0

0

43.315

17.6

45

10.00

LP9.61

R.L. 10.00 ASSUMED TOP OF KERBSITE B.M. WHITE

AR

C. 17.7

55

R. 47.0

0

ED

GE

OF

BIT

UM

EN

BA

CK

OF

KE

RB

CR

OW

N O

F R

OA

D

TR

0101

01TR

0101

01

TR

0101

01

TR

0101

01

TR

0101

01

LOT 5DP 1207153

738.8m²

LOT 4

6

G O

V E

R N

M E

N T

R

O A

D

K I N

G H

A M

C

IRC

UIT

(C)

(C)

(C)

(C)

N

SMH9.70

SMH

SMH10.12

WALL SETOUT LINEPA

RA

LLE

L

WA

LL S

ET

OU

T

100°15'50"40.00

CONCRETE DRIVE & PATHWITH DRY SPRAY FINISH

32m2 APPROX

AP

PR

OX

AP

PR

OX

APPROX

APPROX

AP

PR

OX

5000L

5000L

PAVERS29m2 APPROX CONCRETE DRIVE & PATH

WITH DRY SPRAY FINISH59m2 APPROX

WALL SETOUT LINE

2.5% fall2.5% fall

R.L 9.6R.L 10.3

9% fall

2.5% fall3.0% fall

CUT

FILL

9.50

RA

MP

DO

WN

9.71

Site PlanScale 1:200

BASIX NOTES:SITE AREA: 738.8m2

TOTAL ROOF AREA: 372.9m2

UNIT 1:COND AREA: 127.34m2

UN-COND AREA: 65.67m2

LANDSCAPED AREA: 114.8m2

CATCHMENT AREA: 200.8m2

RAINTANK: 5000L CONNECTED TOTOILETS, EXTERNAL TAPS ANDCOLDWATER TAP TO WASHING MACHINEUNIT 2:COND AREA: 140.82m2

UN-COND AREA: 112.61m2

LANDSCAPED AREA: 124.6m2

CATCHMENT AREA: 172.1m2

RAINTANK: 5000L CONNECTED TOTOILETS, EXTERNAL TAPS ANDCOLDWATER TAP TO WASHING MACHINEALL TAPS TO BE 4 STAR RATEDALL TOILETS TO BE 3 STAR RATED

CONSTRUCTIOND.J.B

NOTE:STORMWATER TO ENGINEER DETAIL &LANDSCAPING TO CONSULTANTS DETAIL

R1 SITE: 360.6m2R1: FOOTPRINT: 171.46m2SITE COVERAGE: 47.5%R2 SITE: 378.2m2R2: FOOTPRINT: 158.72m2SITE COVERAGE: 42.0%

NOTE:STORMWATER, WASTE WATER DISPOSAL & METER BOXLOCATIONS TO BE DETERMINED ON SITE.

NOTE:ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS

NOTE:DEVELOPMENT TO COMPLY WITH ACOUSTIC REPORT BY REVERB ACOUSTICS REF: 08-1226-R2 DATED: 02/11/13

NOTE:ENSURE SAWCUTS/KEY JOISTSTO DRIVEWAY AS REQUIRED

Page 2: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:120, 1:1

2 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERS

AUSTRALIA NSW

®

AREAS: RES 2

1. Lower Living

2. Upper Living

3. Garage

4. Upper Alfres

5. Porch

99.83

71.79

36.36

21.24

2.35

231.57 m2

24-0

6LW

06-1

8F

G

24-18SD

12-0

8LW

24-0

6LW

24-2

4S

D

24-06LW06-21FG 06-18FG

24-0

9LW

24-0

9LW

820

820

24-12 WHITE GLASS

24-14 MIRROR

24-1

8 M

IRR

OR

820

720

720

820

720

24-2

7S

T

24-36ST 720

24-0

9LW

82024-1

5S

D24-2

4S

D24-2

4S

D

820 24-05LW

23-1

8 M

IRR

OR

720820

23-1

8 M

IRR

OR

820

23-14 WHITE GLASS

24-09LW 06-18FG

06-1

5F

G

15-0

6F

G

24-36SD-4

820

820

15-0

6F

G

2.4

x2.7

SE

CT

/ST

EE

L D

OO

R

1200

720 CSD

720 C

SD

2.4

x4.8

SE

CT

ION

AL S

TE

EL D

OO

R

820 CSD

1200

2x820 CSD720 C

SD

720 C

SD

1,7

80

15 90

3,4

20

90 5

109

01,0

00

79070 130250

1,0

20

70

930

70

1,0

20

9015

4,6

90

6001590 8,500 1,710 70 1,020 180 2,720 70 1,620 70 1,630 70 1,320 70 3,730 90

151,510

1590 8,500 90 1,620 70 1,020 90

901,070 1,650 70 1,620 70 3,020 70 950 70 3,620 90

15600

900 4,000 15180

3,320 90 1,00090

600 1,020 70 1,730 20070200

70 1,650 70 1,620 70 3,020 70 95070

53070

3,0209015

4959015

915 90 3,895 15180

3,320 90 1,000 90 3,620 9015

3,540 1590

63070

6,020 9015

1,610

4,900 8,420 3,540 6,930 1,610

615 24,485

1,270 6,650 5,300 6,230 1,000 1,510

90 1,1801590 3,020

90510

90600 2,130 90

155,300

1590 6,020 90

151,000 1,510

1590 3,620 90 1,730 1,000 90 3,420 200

901,420 200

906,020 90

151,000 1,510

1590 2,510 90 1,020 90 1,020 90 1,620 90 3,620 90 1,620 90 6,020 90

151,000 925

135450

4,4101590 3,020

90510

901,020 90 1,620 90

154,000

1590230

701,000 4,250 2,770 90

151,510

1590

5,8

00

90

1,0

00

990

907

0 90

1,0

20

705307

03,0

20

70

930

70

2,0

20

9015

5,8

90

1590

1,9

90

250

1,6

20

70

1,0

20

70

1,9

30

70

3,0

20

9015

5,8

90

135

1,9

45

15907

0 90 15

1,5

70

1590

2,8

45

1590 7

090 1

53,0

90

5,8

90

2,0

80

280

1,5

70

2,9

50

280

3,0

90

16,1

40

1,7

80

15 90

4,0

20

90

1,0

00

9015

885

250

1,0

20

70

1,2

20

70

730

9015

4,6

90

1590

920

140

1,9

60

90

4,0

70

90

610

250

4,7

10

90

620

70

2,3

10

9015

1590

1,9

10

90

1,0

20

90

1,0

20

90 5

509

01,0

20

90

1,9

10

250

4,8

00

900

2,1

00

9015

1590

3,0

20

90

1,6

60

90

3,0

20

907

0 90

7,8

00

9015

900

1,1

80

90

5,7

20

90

890

15

9070 9

04,7

10

18015

2,8

95

9015

900

7,9

70

280

4,8

90

3,9

00

1590

1,6

50

140

1,2

30

90

2,6

90

90

1,2

90

700

250

1,0

20

304

1,6

96

70

1,0

20

70

3,6

20

9015

1,7

80

1590

4,0

20

90

1,0

00

9015

885

250

1,0

20

70

1,2

20

70

1,7

10

90

3,6

20

9015

105

22.525 2

2.5

105

EQ.EQ.

25,100

900

eq. 1,200 1,200 eq.

VELUX 550W x 700L FIXED SKYLIGHT(SQ SET VAULTED OPENING)

SUSPENDEDCONC. SLAB

OVER

WINDOWS TO SIT ON BENCHTOP 915mm A.F.L (FRAME MANUFACTURER TO MAKE SILL HEIGHT 870mm)

90mm WALLTO CSD

90mm WALLTO CSD

O`HEAD C`BRDS& R`HOOD OVER

CONCEALED CISTERNWALL MOUNTED TOILET

CONCEALEDCISTERN

WALL MOUNTEDTOILET

SQ SET BEAM OVERSEE SECTION DETAIL

PLUMBINGSTACK

PLUMBING STACK (TO BE DISCUSSED)

4x 3000x1200x6mmVERSILUX SHEETS WITH

19x19mm PERIMETER BEAD

6mm

MIN

GLA

ZIN

G T

O D

OO

R/H

I-LI

TE

AS

PE

R A

CO

US

TIC

RE

PO

RT

6mm

MIN

GLA

ZIN

G T

O D

OO

R/H

I-LI

TE

AS

PE

R A

CO

US

TIC

RE

PO

RT

90mm RAKING WALL

GYPROCK SHAFTLINER PARTY WALLSYSTEM (No CSR 360)

10mm SUPERCHEK GYROCK & R2.7SOUND BATTS TO EACH INTERNAL SIDE

(SEE SECTION)

2x 3000x1200x6mm VERSILUX SHEETS ONBATTENS TO UNDERSIDE OF SUSPENDED SLAB VENTED EAVE SHEET

VENTED EAVE SHEET

300mm DROPPEDCEILING FOR A/C

FRAMELESSSHOWER SCREEN

refspace

1650mm

d/wspace

B`BAR

UBO

KITCHEN GARAGE

BED 3

ENTRY

BED 2

900

VA

Nca

b-m

ade

wal

l hun

g

1000x1200

BED 1

900

VA

Nca

b-m

ade

wal

l hun

g

1000x1200

LIVING

ALFRESCO 1

DINING

LINENROBE

RO

BE

PTY

LIN

EN

w/m

spac

e

PORCH

HWD TIMBER DECK

LINEN

WIR

nich

e

nich

e

1000

h x

200w

tile

d bo

x

cutout (see detail)

HWD TIMBER DECK

HWD TIMBERDECK

4x s

helv

es c

ab-m

ade

cab-madeappliance

shelf

RAKED CEILING

cab-

mad

ebe

nch

NO SETDOWN

cornerlessstacker

GARAGENO SETDOWN

BED 3

BED 1

BED 2

1650

mm90

0 V

AN

cab-

mad

ew

all h

ung

ENTRY

BENCH(cab-made)

WIR

1000x1200

1600x1000

PORCHRO

BE

RO

BE

w/mspace

LINEN

LINEN

1500

VA

Nca

b-m

ade

wal

l hun

g

BROOM

200w

x 1

000h

tile

d bo

x

cab-madebench

VOID OVER

UPPOLISHED HARDWOOD STAIRS(center stringer with open risers)

PAVEDAREA

LIGHT COURT VOID OVER

ST

EE

L B

EA

M O

VE

RS

TE

EL

BE

AM

OV

ER

ST

EE

L B

EA

M O

VE

R

no h

ob

no hob

HI-

LIT

E O

VE

RRAKED CEILING

HWD TIMBERDECK

FC SHEETCEILING

FC SHEETCEILING

AIR

CO

N

sq s

et b

ox

no h

ob

no hob

B`H

EA

D (

2400

FR

OM

FF

L)

1200h nib wall

1200h nib wall

hosecock

DP

DPDP

DP

DPDPDP

DP

DP

DP DP DP

DP

DPDPhose cock

PUMP

GAS (instantaneous)

PU

MP

VERSILUX SHEET CEILING

STEP DOWN

angled wall

living/dining

nib

deck

alfrescopost kitchen

linen

pty

nib

wir shr

shr

ens

bath

bath

bath wc

wc

powder robe linen

bed 2

bed 2 hall

hall

robe

entry

bed 3

bed 3

bed 1 courtyard garage

nib

porch

box

bed 3

laundry

bed 2

bed 2post robe bath

halllinen

robe brm nook

wir

nib bed 1

bed 1

light court

ens/linen

ens

stack stairs

garage

garage

garage

entry porch

post

box boxbath

nib

deck

kitchen

living/dining

shr

linen

bed

1

ens

gara

ge

linen

hall

light

cou

rt

hall

stai

rs

post

hall

hall

hall en

try

porc

h

lin/r

obe

vani

tyshr

wc

wal

l uni

t

hall

robe

bed

2/be

d 3

deck

cour

tyar

d

linen

nib

gara

ge

laun

dry

bed

1

stac

k

wir

shrha

ll

bath

bathrobe

bed

2

post

post

bed

3

robe

hall

linen

hall

hall

hall

light

cou

rt

brm

hall

hall

shr

angl

edw

all

dini

ng

dini

ng/k

itche

n

livin

gal

fres

co

isla

nd

linen

hall

ens

bed

1

b'he

ad

pty

deck

post

laun

dry

nib

wc

nib

hall

dini

ng

hosecock

hosecock

(see

det

ail)

box

(RE

MO

TE

)(R

EM

OT

E)

MH

RAKED CEIL

ING

STEEL BEAM OVER IN CEILING

BEAMOVER

BEAM OVER

RA

KIN

G B

EA

M O

VE

R

LINE OF UPPER FLOOR ABOVE

BEAM

OVER

nook

RAKED CEILIN

G

deck

BEAM OVER(IN CEILING)

HARDIGROOVECEILING LINING

HARDIGROOVECEILING LINING

(300w)

SQ

SE

TB

EA

M O

VE

R

BE

AM

OV

ER

(IN

CE

ILIN

G)

06-21LW/FG/LW

2100H

06-21LW/FG/LW

2100H

2100H

06-30LW/FG/LW

2100H

12-15LW/FG

12-15FG/LW 12-15LW/FG

WA

LL M

OU

NT

ED

CLO

TH

ES

LIN

E

party wall length

MBOX

MBOX

entr

y

porc

h

deck

deck

rece

ss

BEAM OVER

lift-off hinge

ALFRESCO 2

2340h

PIV

OT

HI-

LIT

E O

VE

R2340h

PIV

OT

2040h2040h

2040h2040h

2040h

2040h

2040h

2040h

2040h

hosecock

24-2

1S

D(T

EM

PO

RA

RY

)24-2

1S

D(T

EM

PO

RA

RY

)

tow

el r

ail

towel rail

towel rail

tow

el r

ail

Ensuite4.62 m2

Bathroom8.24 m2

Laundry1.21 m2

Bathroom4.64 m2

Powder3.29 m2

Ensuite5.54 m2

Laundry4.17 m2

CAB-MADE WALLUNIT SEE DETAIL

TEMPORARY FRAMEDWALL FOR SALES OFFICE

(TO BE REMOVED AT ALATER DATE)

(instantaneous)GAS

cab-

mad

ew

all u

nit

AREAS: RES 1

1. Living

2. Garage

3. Alfresco 1

4. Porch

136.98

21.66

12.00

1.56

172.20 m2

Floor Plan - NOT TO SCALEScale 1:120

RESIDENCE 1Ext Perimeter: 49.94 l/m(not inc party wall)Kitchen: 4.84 l/mWet Areas: 13.76m2

Raked Ceilings: 70.23m2

Alfresco 1 Deck: 19.1m2

Alfresco 2 Deck: 16.6m2

RESIDENCE 2Lower Ext Perimeter: 38.650 l/m(not inc party wall)Lightwell Perimeter: 5.830 l/m(not inc party wall)Upper Ext Perimeter: 42.840 l/mKitchen: 7.1 l/mWet Areas: 19.8m2

Raked Ceilings: 83.4m2

Timber Deck: 3.2m2

Paved Area: 28.7m2

NOTE: ALL EXT. & INT. DOOR AND WINDOWHEAD HEIGHTS ARE 2400H (NOM) UNLESSNOTED OTHERWISE

NOTE: ALL EXT WALL OUTER FACES TO BE SHEETED WITH 15mm PLY (PRIOR TO CLADDING)& 13mm GYPROCK TO INTERNAL WALL FACE AS PER ACOUSTIC REPORT

NOTE: ALL GLAZED DOORS & WINDOWSTO COMPLY WITH MINIMUM RW RATINGSAS PER ACOUSTIC REPORT

(under-roof)

Page 3: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

3 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERS

AUSTRALIA NSW

®

24-0

6LW

06-1

8F

G

24-18SD

12-0

8LW

24-0

6LW

24-2

4S

D

24-06LW06-21FG 06-18FG

24-0

9LW

24-0

9LW

820

820

24-12 WHITE GLASS

24-14 MIRROR

24-1

8 M

IRR

OR

820

720

720

820

720

24-2

7S

T

24-36ST 720

24-0

9LW

820

24-1

5S

D24-2

4S

D24-2

4S

D

820 24-05LW

23-1

8 M

IRR

OR

720820

23-1

8 M

IRR

OR

820

23-14 WHITE GLASS

24-09LW 06-18FG

06-1

5F

G

15-0

6F

G24-36SD-4

820

820

15-0

6F

G

2.4

x2.7

SE

CT

/ST

EE

L D

OO

R

1200

720 CSD

720 C

SD

2.4

x4.8

SE

CT

ION

AL S

TE

EL D

OO

R

820 CSD

1200

2x820 CSD

720 C

SD

720 C

SD

VELUX 550W x 700L FIXED SKYLIGHT(SQ SET VAULTED OPENING)

SUSPENDEDCONC. SLAB

OVER

WINDOWS TO SIT ON BENCHTOP 915mm A.F.L (FRAME MANUFACTURER TO MAKE SILL HEIGHT 870mm)

90mm WALLTO CSD

90mm WALLTO CSD

O`HEAD C`BRDS& R`HOOD OVER

CONCEALED CISTERNWALL MOUNTED TOILET

CONCEALEDCISTERN

WALL MOUNTEDTOILET

SQ SET BEAM OVERSEE SECTION DETAIL

PLUMBINGSTACK

PLUMBING STACK (TO BE DISCUSSED)

4x 3000x1200x6mmVERSILUX SHEETS WITH

19x19mm PERIMETER BEAD

6mm

MIN

GLA

ZIN

G T

O D

OO

R/H

I-LI

TE

AS

PE

R A

CO

US

TIC

RE

PO

RT

6mm

MIN

GLA

ZIN

G T

O D

OO

R/H

I-LI

TE

AS

PE

R A

CO

US

TIC

RE

PO

RT

90mm RAKING WALL

GYPROCK SHAFTLINER PARTY WALLSYSTEM (No CSR 360)

10mm SUPERCHEK GYROCK & R2.7SOUND BATTS TO EACH INTERNAL SIDE

(SEE SECTION)

2x 3000x1200x6mm VERSILUX SHEETS ONBATTENS TO UNDERSIDE OF SUSPENDED SLAB VENTED EAVE SHEET

VENTED EAVE SHEET

300mm DROPPEDCEILING FOR A/C

FRAMELESSSHOWER SCREEN

refspace

1650mm

d/wspace

B`BAR

UBO

KITCHEN GARAGE

BED 3

ENTRY

BED 2

900

VA

Nca

b-m

ade

wal

l hun

g

1000x1200

BED 1

900

VA

Nca

b-m

ade

wal

l hun

g

1000x1200

LIVING

ALFRESCO 1

DINING

LINENROBE

RO

BE

PTY

LIN

EN

w/m

spac

e

PORCH

HWD TIMBER DECK

LINEN

WIR

nich

e

nich

e

1000

h x

200w

tile

d bo

x

cutout (see detail)

HWD TIMBER DECK

HWD TIMBERDECK

4x s

helv

es c

ab-m

ade

cab-madeappliance

shelf

RAKED CEILING

cab-

mad

ebe

nch

NO SETDOWN

cornerlessstacker

GARAGENO SETDOWN

BED 3

BED 1

BED 2

1650

mm90

0 V

AN

cab-

mad

ew

all h

ung

ENTRY

BENCH(cab-made)

WIR

1000x1200

1600x1000

PORCHRO

BE

RO

BE

w/mspace

LINEN

LINEN

1500

VA

Nca

b-m

ade

wal

l hun

g

BROOM

200w

x 1

000h

tile

d bo

x

cab-madebench

VOID OVER

UPPOLISHED HARDWOOD STAIRS(center stringer with open risers)

PAVEDAREA

LIGHT COURT VOID OVER

ST

EE

L B

EA

M O

VE

RS

TE

EL

BE

AM

OV

ER

ST

EE

L B

EA

M O

VE

R

no h

ob

no hob

HI-

LIT

E O

VE

RRAKED CEILING

HWD TIMBERDECK

FC SHEETCEILING

FC SHEETCEILING

AIR

CO

N

sq s

et b

ox

no h

ob

no hob

B`H

EA

D (

2400

FR

OM

FF

L)

1200h nib wall

1200h nib wall

hosecock

DP

DPDP

DP

DPDPDP

DP

DP

DP DP DP

DP

DPDPhose cock

PUMP

GAS (instantaneous)

PU

MP

VERSILUX SHEET CEILING

STEP DOWN

hosecock

hosecock

(see

det

ail)

(RE

MO

TE

)(R

EM

OT

E)

MH

RAKED CEIL

ING

STEEL BEAM OVER IN CEILING

BEAMOVER

BEAM OVER

RA

KIN

G B

EA

M O

VE

R

LINE OF UPPER FLOOR ABOVE

BEAM

OVER

RAKED CEILIN

G

BEAM OVER(IN CEILING)

HARDIGROOVECEILING LINING

HARDIGROOVECEILING LINING

(300w)

SQ

SE

TB

EA

M O

VE

R

BE

AM

OV

ER

(IN

CE

ILIN

G)

06-21LW/FG/LW

2100H

06-21LW/FG/LW

2100H

2100H

06-30LW/FG/LW

2100H

12-15LW/FG

12-15FG/LW 12-15LW/FG

WA

LL M

OU

NT

ED

CLO

TH

ES

LIN

E

MBOX

MBOX

rece

ss

BEAM OVER

lift-off hinge

ALFRESCO 2

2340h

PIV

OT

HI-

LIT

E O

VE

R2340h

PIV

OT

2040h

2040h

2040h2040h

2040h

2040h

2040h

2040h

2040h

hosecock

24-2

1S

D(T

EM

PO

RA

RY

)24-2

1S

D(T

EM

PO

RA

RY

)

tow

el r

ail

towel rail

towel rail

tow

el r

ail

Ensuite4.62 m2

Bathroom8.24 m2

Laundry1.21 m2

Bathroom4.64 m2

Powder3.29 m2

Ensuite5.54 m2

Laundry4.17 m2

CAB-MADE WALLUNIT SEE DETAIL

TEMPORARY FRAMEDWALL FOR SALES OFFICE

(TO BE REMOVED AT ALATER DATE)

(instantaneous)GAS

cab-

mad

ew

all u

nit

900

790

1,0

00

300

1,2

00

300

600

R2 ENSUITE DETAIL R2 BOX DETAIL

200dsq. set box

R2 SHOWER DETAIL

90d niche

polished edgemirror over

200w tiled box

1500 vanity(cab-made)

shwr

1,2

00

1,0

00

1,2

00

300

300 300

550

1,0

00

300

900

cab-made recessed wallunit with mirror fixed to door

R1 CUTOUTDETAIL

cutoutopening

R1 TYPICALSHOWER DETAIL

90d niche

R1 ENS DETAIL

200w tiled box

900 vanity(cab-made)

adj shelf

adj shelf

Ground Floor PlanScale 1:100

NOTE: ALL EXT. & INT. DOOR AND WINDOWHEAD HEIGHTS ARE 2400H (NOM) UNLESSNOTED OTHERWISE

N

Page 4: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

4 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERSAUSTRALIA NSW

®

06-30 OPENING

06-30FG

06-15FG12-06FG

720

09-06FG

06-30FG

6,740 15180

4,020 9015

4,000 1590230

70910 70 2,020 70 1,680 90

15495

1054,180

90 3,510 15180

9,440 90 4,250

3,600 15180

9,440 9015

3,735 9015

13,340 3,840 600

3,140 3,600 4,320 4,000 5,860 4,180

1590

5,7

10

790

70 130105

1590

5,7

10

9015

990

1590

6,7

00

9015

6,9

10

90

5,7

20

90

1,0

10

5,9

00

1,0

10

1590

5,7

10

990

9015

1590

4,7

10

1,0

00

70

920

90 15

4,7

10

1590

1,0

00

990

9015

4,7

10

1,9

20

280

equal

1,2

00

1,2

00

1,2

00

equal

3,140 3,600 14,180 4,180

900

700

200

600

300

O`HEAD C`BRDS, R`HOOD & 2400hPLASTER BULKHEAD OVER

DUCTED MECHANICALVENTILATION TO BCA REQ

5x 3600x1200x6mmVERSILUX SHEETS WITH

19x19mm PERIMETER BEAD

SQ SET BEAM(SEE DETAIL)

15mm PLY TO START FROM TOP OF LOWERADJOINING UNIT ROOF & CONTINUE UPWARDS

VENTED EAVE SHEET

MIRRORED SPLASHBACK

LIVING

refspace

d/wspace

B`BAR

UBO

DINING

KITCHEN

PTY VOIDhandbasin

ALFRESCO

12-36AW

24-5

4S

T

12-3

6A

W

CONC. TILED RAKED CEILING

RAK

ED C

EILI

NG

1000h WALL

RA

KIN

G B

EA

M O

VE

R

sq s

et b

ox

LIGHT COURTYARD - VOID BELOW

SPREADER SPREADER SPREADER

SPREADER

DP

VERSILUX CEILING

alfresco

alfrescopost

kitchen courtyard

dining/lounge stairs

nibvoidpowderhallstack

livin

g

dini

ng/k

itche

n

alfr

esco

post co

urty

ard

livin

gbo

xst

ack

wc

stai

rs

stai

rsvo

id

(see

det

ail)

p. stack

kitc

hen

LINE OF STOREY BELOW LINE OF STOREY BELOW

LINE OF STOREY BELOW

2100H 2100H

VELUXSKY

LIGHT

courtyard

hosecock

gascock

lift-

off h

inge

m/ospace

a/c ducts Upper Powder1.86 m2

600

790

R2 BOX DETAIL

200dsq. set box

Upper Floor PlanScale 1:100

NOTE: WINDOWS RESTRICTEDAS PER B.C.A 2013

N

NOTE: ALL EXT. & INT. DOOR AND WINDOWHEAD HEIGHTS ARE 2400H (NOM) UNLESSNOTED OTHERWISE

NOTE: ALL EXT WALL OUTER FACES TO BE SHEETED WITH 15mm PLY (PRIOR TO CLADDING)& 13mm GYPROCK TO INTERNAL WALL FACE AS PER ACOUSTIC REPORT

NOTE: ALL GLAZED DOORS & WINDOWSTO COMPLY WITH MINIMUM RW RATINGSAS PER ACOUSTIC REPORT

Page 5: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

5 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDING

DESIGNERS

AUSTRALIA NSW

®2,7

40

2,7

40

2,1

00

2,1

00

2,1

00

HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH

'SCYON' STRIA CLADDINGCOLORBOND ROOF @ 5° PITCH

HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH'SCYON' AXON CLADDING

OPENING TO DECK

ALUMINUM ADAPTORTRIM TO ALL LOUVRES

EASYLAP HORIZONTALALUM JOINER STRIP

Finished slab height

Underside of trusses

Finished ground height

Finished floor height

Underside of floor joists

easylap setout from center of windoweasylap setout from center of wall easylap setout from internal cornereasylap setout from ext corner

2,7

40

2,7

40

2,7

40

600

600

450 450

COLORBOND ROOF @ 5° PITCH

'SCYON' STRIA 300h CLADDING

COLORBONDROOF @ 8° PITCH

HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH

'SCYON' AXON CLADDING

135x135 STAINEDHWD TIMBER POST

ALUMINUM ADAPTOR TRIM TO ALL LOUVRES

NIB WALL CLAD IN HARDIESEASYLAP WITH TEXTURE COAT FINISH

NIB WALLS CLAD IN HARDIESEASYLAP WITH TEXTURE COAT FINISH

COLORBOND ROOF @ 5° PITCH

Finished slab height

Underside of trusses

Finished ground height

Finished floor height

Underside of floor joists

Finished slab height

Underside of trusses

easylap setout from edge of g/door easylap setout from center of g/door

TEMPORARY FRAMED WALL FOR SALES OFFICE(TO BE REMOVED AT A LATER DATE)

Left ElevationScale 1:100

Front ElevationScale 1:100

NOTE:

THESE DRAWINGS ARE A PICTORIAL INDICATION ONLY,

SOME VARIATION MAY OCCUR ON SITE.

NOTE:

ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS

THERMAL COMFORT COMMITMENTS:

-R 1.0 ANTICON BLANKET TO ROOF

-R 3.0 BATTS TO CEILING

-R 1.0 SISALATION TO EXT. WALLS

-R 2.0 BATTS TO EXT. WALLS

NOTE: ALL GLAZED DOORS & WINDOWS

TO COMPLY WITH MINIMUM RW RATINGS

AS PER ACOUSTIC REPORT

Page 6: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

6 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDING

DESIGNERSAUSTRALIA NSW

®

2,7

40

2,7

40

HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH

WINDOWS TO SIT ON BENCHTOP 915mm A.F.L(FRAME MANUFACTURER TO MAKE SILL HEIGHT 870mm)

ALUMINUM ADAPTORTRIM TO ALL LOUVRES

HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH

Finished slab height

Underside of trusses

Finished ground height

Finished floor height

Underside of floor joists

easylap setout from ext corners

easylap setout from ext corner easylap setout from ext corner

easylap setout from center of window

easylap setout from int corner

'SCYON' AXON CLADDINGVELUX FIXED SKYLIGHT RAISED/FRAMED UP

TO 15° AS PER MANUFACTURERS SPEC

2,7

40

2,7

40

2,7

40

450

600

450

COLORBOND ROOF @ 5° PITCH

COLORBOND ROOF @ 8° PITCH

1020h POWDERCOATED ALUMBALUSTRADE WITH S/S WIRE

TO N.C.C. REQUIREMENTS

HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH

RAKING DUMMY BEAM OVER

ALUMINUM ADAPTORTRIM TO ALL LOUVRES

90x90 STAINEDHWD TIMBER POST

'SCYON' AXON CLADDING

VELUX SKLIGHT

Finished slab height

Finished ground height

Underside of trusses

Finished floor height

Underside of floor joists

Finished slab height

Underside of trusses

easylap setout from edge of sliding door

horizontal alum joiner

90x90 GAL STEEL POSTS (UNPAINTED)

Right ElevationScale 1:100

Rear ElevationScale 1:100

NOTE:

THESE DRAWINGS ARE A PICTORIAL INDICATION ONLY,

SOME VARIATION MAY OCCUR ON SITE.

NOTE:

ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS

THERMAL COMFORT COMMITMENTS:

-R 1.0 ANTICON BLANKET TO ROOF

-R 3.0 BATTS TO CEILING

-R 1.0 SISALATION TO EXT. WALLS

-R 2.0 BATTS TO EXT. WALLS

NOTE: ALL GLAZED DOORS & WINDOWS

TO COMPLY WITH MINIMUM RW RATINGS

AS PER ACOUSTIC REPORT

Page 7: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

7 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERS

AUSTRALIA NSW

®

Electrical - R2

Electrical Item

011257 - Clayton 1lt CeramicPendant-Black

170550 - LEDLUX 3m RibbonII Kit IP65 Warm WH

170565 - 11w LEDLUX VIVID700LM Dim DL - White-WW

190406 - 28w Horizo II mirrorlight - Silver-Frost Glass

2 - Way Light Switch

200026 - Thermalite 3 in 1- 2Lamp - White

200241 - Hellar Round fan-light - SS

210260 - ARTEMIS 58in Fan-Light - Matt Black

210817 - 48in Altitude Eco18w LED - White

3 - Way Light Switch

300866 - LEDLUX FORO4.5w Rec Steplight - White

Datapoint

Dimmer

Double GPO 1050mm AFL

Double GPO 300mm AFL

Double GPO Weather Proof

Flourescent Tube Light

Garage Remote

Phone Point

Sensor

Single GPO 1050mm AFL

Single GPO 1900mm AFL

Single GPO 300mm AFL

Single GPO Weather Proof

Smoke Alarm

TV Point

Wall Light

Symbol

011257

P

170550

170565

190406

2w

200026

200241

210260

210817

3w

300866

D

Dim

WP

Remote

WP

TV

Quantity

3

1

34

2

6

2

1

1

3

3

2

8

14

6

15

2

2

1

1

1

1

2

2

2

2

2

2

Electrical - R1

Electrical Item

011030 - Pentone 3lt PendantAsh-Opal

170565 - 11w LEDLUX VIVID700LM Dim DL - White-WW

190406 - 28w Horizo II mirrorlight - Silver-Frost Glass

2 - Way Light Switch

200026 - Thermalite 3 in 1- 2Lamp - White

210817 - 48in Altitude Eco18w LED - White

Datapoint

Dimmer

Double Fluorescent TubeLight

Double GPO 1050mm AFL

Double GPO 300mm AFL

Garage Remote

Phone Point

Sensor

Single GPO 1050mm AFL

Single GPO 1900mm AFL

Single GPO 300mm AFL

Single GPO Weather Proof

Smoke Alarm

TV Point

Symbol

011030P

170565

190406

2w

200026

210817

D

Dim

Remote

WP

TV

Quantity

1

31

1

2

2

3

2

7

1

7

14

1

1

1

1

2

1

2

2

2

24-0

6LW

06-1

8F

G

24-18SD

12-0

8LW

24-0

6LW

24-2

4S

D

24-06LW06-21FG 06-18FG

24-0

9LW

24-0

9LW

820

820

24-12 WHITE GLASS

24-14 MIRROR

24-1

8 M

IRR

OR

820

720

720

820

720

24-2

7S

T

24-36ST 720

24-0

9LW

820

24-1

5S

D24-2

4S

D24-2

4S

D

820 24-05LW

23-1

8 M

IRR

OR

720820

23-1

8 M

IRR

OR

820

23-14 WHITE GLASS

24-09LW 06-18FG

06-1

5F

G

15-0

6F

G

24-36SD-4

820

820

15-0

6F

G

2.4

x2.7

SE

CT

/ST

EE

L D

OO

R

1200

720 CSD

720 C

SD

2.4

x4.8

SE

CT

ION

AL S

TE

EL D

OO

R

820 CSD

1200

2x820 CSD

720 C

SD

720 C

SD

210817

TV

D

Rem

ote

WP

210817

170565170565

170565

210817

170565

200026

200026

170565

170565

3w

3w

3w

2w2w

170565 170565

170565

170565

170565

TV

DR

em

ote

WP

210817

210817170565

200026

170565

170565170565

210817

170565

170565

170565 170565

200026

2w 2w2w

WPWP

170565

2w2w

170565

DD

TV

170565

170565

170565

170565

170565

170565170565

170565

170565

170565

170565 170565

170565 170565

170565

170565

170565

170565

170565

011030P

190406

Dim

Dim

Dim

Dim

Dim

Dim

Dim

170565

170565

Dim

170565

190406

170565

170565

170565

170565

Dim

Dim

Dim Dim

Dim Dim

Dim

190406

170565

170565

170565

170565

170565

170565

170565

WP

D

D

D

D

D

D

SINGLE GPO FORD/W & R/HOOD

DOUBLE GPO FOR FUTURE NBN

DOUBLE GPO FOR FUTURE NBN

SINGLE EXT GPOFOR PUMP

SIN

GLE

EX

T G

PO

FO

R P

UM

P

SINGLE EXT GPOFOR HWS

SINGLE EXT GPOFOR HWS

refspace

1650mm

d/wspace

1000x1200

1000x1200

LINENROBE

RO

BE

PTY

LIN

EN

w/m

spac

e

LINEN

WIR

nich

e

nich

e

1000

h x

200w

tile

d bo

x

cutout (see detail)

4x s

helv

es c

ab-m

ade

cab-madeappliance

shelf

cab-

mad

ebe

nch

1650

mm

RO

BE

RO

BE

w/mspace

ST

EE

L B

EA

M O

VE

R

AIR

CO

N

no h

ob

no hob

hosecock

DP

DPDP

DP

DPDPDPD

P

DP

DP DP DP

DP

DPDPhose cock

PUMP

GAS (instantaneous)

PU

MP

hosecock

hosecock

(RE

MO

TE

)(R

EM

OT

E)

MH

STEEL BEAM OVER IN CEILING

BEAMOVER

BEAM OVER

RA

KIN

G B

EA

M O

VE

R

(300w)

SQ

SE

TB

EA

M O

VE

R

BE

AM

OV

ER

(IN

CE

ILIN

G)

06-21LW/FG/LW

2100H

06-21LW/FG/LW

2100H

2100H

06-30LW/FG/LW

12-15LW/FG

12-15FG/LW 12-15LW/FG

MBOX

MBOX

2040h

2040h

2040h2040h

2040h

2040h

2040h

2040h

2040h

hosecock

24-2

1S

D(T

EM

PO

RA

RY

)24-2

1S

D(T

EM

PO

RA

RY

)

(instantaneous)GAS

cab-

mad

ew

all u

nit

Lower Electrical PlanScale 1:100

Page 8: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

8 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERSAUSTRALIA NSW

®

06-30 OPENING

06-30FG

06-15FG12-06FG

720

09-06FG

06-30FG

2w

TV

170565

170565

200241

170565

170565

170565 170565

170565 170565

170565

170565

Dim

011257

P

011257

P

011257

P

DimDim

Dim

Dim

WP

170550

170565

300866 300866Dim

210260

DUCTED MECHANICALVENTILATION TO BCA REQ

SINGLE GPO FORM/O, D/W & R/HOOD

refspace

d/wspace

PTY12-36AW

24-5

4S

T

12-3

6A

W

SPREADER SPREADER SPREADER

SPREADER

DP

p. stack

LINE OF STOREY BELOW LINE OF STOREY BELOW

LINE OF STOREY BELOW

2100H 2100H

hosecock

gascock

lift-

off h

inge

m/ospace

a/c ducts

Upper Electrical PlanScale 1:100

NOTE:

SEE LOWER FLOOR ELECTRICAL PLAN FOR QUANTITIES

BASIX NOTES:

ENERGY - ALL DWELLINGS:

*HWS: GAS INSTANTANEOUS - 5 STAR RATED

*COOKTOP/OVEN: ELECTRIC

*RANGEHOOD: NON DUCTED, MAN SWITCH

*LIGHTING: LED LIGHTS TO KITCHEN, LIVING & HALLWAYS

*CLOTHESLINE: EXTERNAL

Page 9: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:1, 1:100

9 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERSAUSTRALIA NSW

®

Legend:Carpet:Vinyl Plank:Tiles:

Floor coverings approx area`s (not inc waste) - R2

Type

R2 Lo Ext Tiles

R2 Lower Carpet

R2 Up Ext Tiles

R2 Low V/Plank

R2 Upp V/Plank

Approx Area (m2)

3.63

41.02

20.56

31.40

54.57

24-0

6LW

06-1

8F

G

24-18SD

12-0

8LW

24-0

6LW

24-2

4S

D

24-06LW06-21FG 06-18FG

24-0

9LW

24-0

9LW

820

820

24-12 WHITE GLASS

24-14 MIRROR

24-1

8 M

IRR

OR

820

720

720

820

720

24-2

7S

T

24-36ST 720

24-0

9LW

820

24-1

5S

D24-2

4S

D24-2

4S

D

820 24-05LW

23-1

8 M

IRR

OR

720820

23-1

8 M

IRR

OR

820

23-14 WHITE GLASS

24-09LW 06-18FG

06-1

5F

G

15-0

6F

G24-36SD-4

820

820

15-0

6F

G

2.4

x2.7

SE

CT

/ST

EE

L D

OO

R

1200

720 CSD

720 C

SD

2.4

x4.8

SE

CT

ION

AL S

TE

EL D

OO

R

820 CSD

1200

2x820 CSD

720 C

SD

720 C

SD

refspace

1650mm

d/wspace

1000x1200

1000x1200

LINENROBE

RO

BE

PTY

LIN

EN

w/m

spac

e

LINEN

WIR

nich

e

nich

e

1000

h x

200w

tile

d bo

x

cutout (see detail)4x

she

lves

cab

-mad

e

cab-madeappliance

shelf

cab-

mad

ebe

nch

1650

mm

RO

BE

RO

BE

w/mspace

ST

EE

L B

EA

M O

VE

R

AIR

CO

N

no h

ob

no hob

hosecock

DP

DPDP

DP

DPDPDP

DP

DP

DP DP DP

DP

DPDPhose cock

PUMP

GAS (instantaneous)

PU

MP

hosecock

hosecock

(RE

MO

TE

)(R

EM

OT

E)

MH

STEEL BEAM OVER IN CEILING

BEAMOVER

BEAM OVER

RA

KIN

G B

EA

M O

VE

R

(300w)

SQ

SE

TB

EA

M O

VE

R

BE

AM

OV

ER

(IN

CE

ILIN

G)

06-21LW/FG/LW

2100H

06-21LW/FG/LW

2100H

2100H

06-30LW/FG/LW

12-15LW/FG

12-15FG/LW 12-15LW/FG

MBOX

MBOX

2040h

2040h

2040h2040h

2040h

2040h

2040h

2040h

2040h

hosecock

24-2

1S

D(T

EM

PO

RA

RY

)24-2

1S

D(T

EM

PO

RA

RY

)

(instantaneous)GAS

cab-

mad

ew

all u

nit

Floor coverings approx area`s (not inc waste) - R1

Type

R1 Carpet

R1 Tiles

Approx Area (m2)

38.93

70.86

Lower Floor Coverings PlanScale 1:100

Page 10: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

10 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDINGDESIGNERSAUSTRALIA NSW

®

Legend:Carpet:Vinyl Plank:Tiles:

06-30 OPENING

06-30FG

06-15FG12-06FG

720

09-06FG

06-30FG

refspace

d/wspace

PTY12-36AW

24-5

4S

T

12-3

6A

W

SPREADER SPREADER SPREADER

SPREADER

DP

p. stack

LINE OF STOREY BELOW LINE OF STOREY BELOW

LINE OF STOREY BELOW

2100H 2100H

hosecock

gascock

lift-

off h

inge

m/ospace

a/c ducts

Upper Floor Coverings PlanScale 1:100

NOTE:SEE LOWER FLOOR COVERINGS PLAN FOR QUANTITIES

Page 11: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

11 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDING

DESIGNERS

AUSTRALIA NSW

®

915 90 3,895

5,8

90

2,0

80

280

1,5

70

2,9

50

280

3,0

90

3,140 90 1,180 6,650 5,300 6,230 1,000 925135

450

1,7

80

1,3

45

1,7

80

1,1

80

90

5,7

20

90

890

280

2,0

40

600

2,2

50

2,8

95

9015

900

7,9

70

280

4,8

90

3,0

00

900

135

1,9

45

600

910 600

1,510

1,510

300600 4,000 8,420 3,540 6,930 1,610

24,991

16,1

40

600 24,500

2,835

3,1

25

3,5

25

2,615

3,2

15

1,6

60

1,620 6,215

2,1

25

805

885

1,3

40

2,0

20

980 1,930 105

2,035

3,0

00

3,8

15

75 4,000

3,140 1,270 18,180 1,000 1,510

2,730 105

4,410

900 580 3,420 220

220

2,5

20

480

810

90

5,610 7,905

600

2045

1,683 45 1,683 4520

65

1,5

27

1,5

27

1,5

27

45

20 90

1,4

37

90

1,4

37

90

1,4

37

90

20 45

1,3

70

45

1,3

70

45

960

45

90 1,507 90 1,507 90 1,507 9020

65

1,3

90

1,4

18

983

45

1,597 1,597 1,596 65

20 90

1,3

50

9020

90

895

90

895

9020

2090 1,310 90

700

400

385

2,4

60

450

1,5

00

455

2,4

50 190 3,620 190

2,4

50

1,0

40

4,6

90

220w x 20dREBATE FOR

STACKING DOOR 130w x 20dREBATE FOR

SLIDING DOOR

130w x 20dREBATE FOR

SLIDING DOOR`S

OUTLINE OF SUSPENDED CONC.SLAB & STEEL BEAM OVER

PLUMBING STACKPLUMBING STACK

100mm SETDOWN WITH FALL TOFIELD GULLY AS PER ENGINEERING

130w x 20d REBATEFOR SLIDING DOOR

END BEARER SPACED20mm FROM SLAB EDGE

END BEARER SPACED20mm FROM SLAB EDGE

END BEARER SPACED20mm FROM SLAB EDGE

END BEARER SPACED20mm FROM SLAB EDGE

ALLOW PLUMBINGTO KITCH. BENCH

PAD FOR A/C ATREBATE HEIGHT

PAD FOR PUMP ATREBATE HEIGHT

PAD FOR PUMP ATREBATE HEIGHT

35mm SETDOWNTO WET AREA

35mmSETDOWN

TO WETAREA

35mm SETDOWNTO WET AREA

35mmSETDOWN TO

WET AREA

35m

m S

ET

DO

WN

TO

WE

T A

RE

A

TOTAL SLAB AREA: 300.2m2

TIMBER DECK

TIMBER DECK

TIMBER DECK

TIMBER DECK

c/l c/l

c/l

c/l

Slab PlanScale 1:100

DECK - END BEARERS140x45 MGP10 TREATED PINE ON HALF STIRRUP POST ANCHOR (BEARER LENGTHS MUST BE CONTINUOUS OVER TWO SPANS WHERE APPLICABLE)DECK JOISTS140x45 MGP10 TREATED PINE IN-LINE WITH BEARERS & SUPPORTED BY JOIST HANGERS ENSURE TERMITE BARRIER

Page 12: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Owners:Job Address: Integrity Projex I Pty.Ltd.

CONSTRUCTIOND.J.B

Lot 5, Kingham Circuit, Thornton.

Drawn:

Date:

Job Number:

Type:

Scale:

Page:

1:50

12 / 14Custom

130107

6/04/2017

DJB Issue:SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566, COFFS HARBOUR NSW, 2450 - PHONE NO. (02) 6652 9600 - FAX NO. (02) 6652 9644

Owners signatures confirm these plans are approved as a representation of what is to be built. Items not included in these plans & attached specification are deemed not to be included in the contract: I / We approve these plans.

INTEGRITYNEW HOMES

Changing my world

®

NOTE:- These plans are copyright in whole & in part to Integrity Projex I Pty. Ltd. & may not be used or reproduced without written permission

BUILDINGDESIGNERS

AUSTRALIA NSW

450

600

450

METAL BATTENS@ 900mm cts

PREFABRICATED TIMBERFRAMES TO MANUFACTURER'S

SPECIFICATIONS

10mm PLASTERBOARDTO CEILINGS

PREFABRICATED TIMBER ROOF TRUSSES @ 8° PITCH.600mm MAX. CENTRES WITH BRACING OF TRUSSES

ALSO TO MANUFACTURER'S SPECIFICATIONS

SMART JOIST RAFTERS @ 5° PITCH.600mm MAX. CENTRES TO TILLINGS SPECIFICATIONS

CONCRETE SLAB

SMART JOIST FLOOR450mm MAX. CENTRES TOTILLINGS SPECIFICATIONS

UNDER SLABMOISTURE BARRIER

WATER PROOFEXPOSED

SLAB EDGE ASREQUIRED

RAKED CEILING

450mm EAVEWITH4.5mm

HARDIFLEX

COLORBOND ROOFING FIXED TOMANUFACTURER'S SPECIFICATIONS

GYPROCK SHAFT LINER PARTY WALL SYSTEMTO CONTINUE TO UNDERSIDE OF ROOFINGAS PER MANUFACTURERS SPECIFICATION

55mm ANTICON BLANKET OVER ROOF BATTENS

R2.0 BATTS TO EXT WALLS

R3.0 BATTSTO CEILINGS

HARDIES CLADDINGS ASPER ELEVATIONS WITH

15mm PLY TO ALL EXTERNALWALLS (BEHIND CLADDINGS)AS PER ACOUSTIC REPORT

13mm GYPROCK TOEXTERNAL WALL AS

PER ACOUSTIC REPORT

GYPROCK SHAFTLINER PARTYWALL SYSTEM (No CSR 360)

10mm SUPERCHEK GYROCK &R2.7 SOUND BATTS TO EACH

INTERNAL SIDE

BULKHEADOVER KITCHEN

COLORBOND ROOF (PITCH VARIES)2740 WALL HEIGHTS - 'H' SOIL CLASSIFICATION

POD POD POD POD POD POD POD POD POD POD POD POD POD

KITCHEN LAYOUT SEEMANUFACTURERS.

DETAIL

REFER TO ENGINEER'S REPORTFOR FOOTING & SLAB DETAILS

2340h INTERNAL DOORS

TERMITE BARRIER TO AS 3660 PARTS 1,2 & 3.INSTALLED AS PER MANUFACTURERS SPECIFICATIONS

SectionScale 1:50

Page 13: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Owners:Job Address: Integrity Projex I Pty.Ltd.

CONSTRUCTIOND.J.B

Lot 5, Kingham Circuit, Thornton.

Drawn:

Date:

Job Number:

Type:

Scale:

Page: 13 / 14Custom

130107

6/04/2017

DJB Issue:SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566, COFFS HARBOUR NSW, 2450 - PHONE NO. (02) 6652 9600 - FAX NO. (02) 6652 9644

Owners signatures confirm these plans are approved as a representation of what is to be built. Items not included in these plans & attached specification are deemed not to be included in the contract: I / We approve these plans.

INTEGRITYNEW HOMES

Changing my world

®

NOTE:- These plans are copyright in whole & in part to Integrity Projex I Pty. Ltd. & may not be used or reproduced without written permission

BUILDING

DESIGNERS

AUSTRALIA NSW

SMART JOIST FLOOR450mm MAX. CENTRES TOTILLINGS SPECIFICATIONS

13mm GYPROCK TOEXTERNAL WALL AS

PER ACOUSTIC REPORT

METAL BATTENS@ 900mm cts

SMART JOIST RAFTERS @ 5° PITCH.600mm MAX. CENTRES TO TILLINGS SPECIFICATIONS55mm ANTICON BLANKET OVER ROOF BATTENS

CONCRETE SLAB

SQ SET BEAM

RAKED CEILINGRAKED CEILING

HARDIES CLADDINGS ASPER ELEVATIONS WITH

15mm PLY TO ALL EXTERNALWALLS (BEHIND CLADDINGS)AS PER ACOUSTIC REPORT

SUSPENDED CONC. SLABTO ENG DETAIL

POD PODPODPODPODPODPOD POD PODPODPODPOD

REFER TO ENGINEER'S REPORTFOR FOOTING & SLAB DETAILS

TERMITE BARRIER TO AS 3660 PARTS 1,2 & 3.INSTALLED AS PER MANUFACTURERS SPECIFICATIONS

UNDER SLABMOISTURE BARRIER

SectionScale 1:60

Page 14: Site survey C....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated pit rw boundary line wm top & toe of banks major contour line minor contour line

Lot 5, Kingham Circuit,

Thornton.

Integrity Projex I Pty.Ltd.

DJB

6/04/2017

130107

Custom

1:100

14 / 14

CONSTRUCTION

D.J.B

Date:

Page:

Issue:

Type:

Scale:

Job Number:

Drawn:

Owners:

Job Address:

SIGNATURE

SIGNATURE

DATE

DATE

HEAD OFFICE: PO BOX 1566,

COFFS HARBOUR NSW, 2450

PHONE NO. (02) 6652 9600

FAX NO. (02) 6652 9644

Owners signatures confirm these plans are

approved as a representation of what is to be

built. Items not included in these plans &

attached specification are deemed not to be

included in the contract:

I / We approve these plans.

NOTE:- These plans are copyright in whole & in part

to Integrity Projex I Pty. Ltd. & may not be used or

reproduced without written permission

INTEGRITYNEW HOMES

Changing my world

BUILDING

DESIGNERS

AUSTRALIA NSW

®

8° R

OO

F P

ITC

H

8° R

OO

F P

ITC

H

8° R

OO

F P

ITC

H

8° R

OO

F P

ITC

H

5° R

OO

F P

ITC

H

5° R

OO

FP

ITC

H

5° R

OO

FP

ITC

H

UPPER FLOOR OVER

VOID

UPPER FLOOR

5° R

OO

F P

ITC

H

5° R

OO

FP

ITC

H

Roof PlanScale 1:100