Site Count for Site Sharkawy

2
SITE NAME CODE Date TIME IN 12:50 Eng Name TIME OUT 15:45 Measurements 220 223 222 221 220 220 384 380 381 0.9 0.8 0.7 15 17 16 30 0 54.43 Access Data Tower Site Power roof top 7 alex port ec 3 no Access road for 4x4 vehicle ( Yes / No ) yes alex port roof top shelter mast no 3 4 port power wave 1 30 yes yes Positive dc (0 vdc) / Ground Negative dc (-48 vdc) / Ground Earth measurement Need Permission ( Yes / No ) Neutral Current KWH meter reading KVARH meter reading No. of GEDP Type of antennas Shelter,GSM Room,Outdoor,indoor Tower,Monopole,Paylon ,Mast Tower Starts From Ground / Roof Top No. of MW dishes access problem ( Yes / No ) Site Location ( City / Road ) Site Type ( Green Field , Roof Top , Indoor) Hieght Owner wire for fixation(supporting wire) ( YES / NO) No. of antennas Size of each dish Type of MW dishes Site Power Configuration ( EC / Gen ) Number of phases connected to site (1,2,3) Power Meter Avillabillity ( Yes / No ) No. of C.B 100A No. of surge arrestor 1 1 1 1 sharkawy Neutral / Phase 220 V Earth / Phase 220 V Phase / Phase 380 V Neutral / Earth AC current /phase 21-5-2014 kirollos onsi No. of D.C box

Transcript of Site Count for Site Sharkawy

Page 1: Site Count for Site Sharkawy

8/12/2019 Site Count for Site Sharkawy

http://slidepdf.com/reader/full/site-count-for-site-sharkawy 1/2

SITE NAME CODE

Date TIME IN 12:50

Eng Name TIME OUT 15:45

Measurements

220 223 222

221 220 220

384 380 381

0.9 0.8 0.7

15 17 16

30

0

54.43

Access Data

Tower

Site Power

roof top

7

alex port

ec

3

no

Access road for 4x4 vehicle ( Yes / No ) yes

alex port

roof top

shelter

mast

no

3

4 port power wave

1

30

yes

yes

Positive dc (0 vdc) / Ground

Negative dc (-48 vdc) / Ground

Earth measurement

Need Permission ( Yes / No )

Neutral Current

KWH meter reading

KVARH meter reading

No. of GEDP

Type of antennas

Shelter,GSM Room,Outdoor,indoor

Tower,Monopole,Paylon ,Mast

Tower Starts From Ground / Roof Top

No. of MW dishes

access problem ( Yes / No )

Site Location ( City / Road )

Site Type ( Green Field , Roof Top , Indoor)

Hieght

Owner

wire for fixation(supporting wire) ( YES / NO)

No. of antennas

Size of each dish

Type of MW dishes

Site Power Configuration ( EC / Gen )

Number of phases connected to site (1,2,3)

Power Meter Avillabillity ( Yes / No )

No. of C.B 100A

No. of surge arrestor

1

1

1

1

sharkawy

Neutral / Phase 220 V

Earth / Phase 220 V

Phase / Phase 380 V

Neutral / Earth

AC current /phase

21-5-2014

kirollos onsi

No. of D.C box

Page 2: Site Count for Site Sharkawy

8/12/2019 Site Count for Site Sharkawy

http://slidepdf.com/reader/full/site-count-for-site-sharkawy 2/2

Rectifier 1 Rectifier 2 Rectifier 3

24

power safe

2

450

1

1

lorain

3

lorain

A / C & Fire

A/C1 A/C2 A/C3

carrier carrier

50 52

copland copland

3 3

Site Usage

BSS Eq Supplier ALC , Motorola

Beacon System

31, gsm(5+8+7), dcs(3+4+4)

2G ( Motorola / Nokia )

Capacity of Air conditioning unit (BTU)

# of Rectefire Cabinets

Rectefire Brand

Apr-14

N/A

1sys ESMC, 1RF FXEA, 2RF FXDA

1

macro

nokia

no

alcatel

1+0

N/A

TYPE OF BEACON LAMP ( Single / Double )( Flasing / Steady )

N/A

MW configuration # / ( 1+0 / 1+1 )

Numbers of Beacon Lamp

1

bavaria

# of TRX's ( Total number of TRX's )

Number Of links / Type of link( Alcatel,NEC,Nokia,Laser,HDSL,Cable,Ericsson)

Fire Panel Type

Fire Extinguisher Type (Powder or CO2)

Fire Extinguisher Brand ( Bavaria,…)

Fire Extinguisher S/N

Fire Extinguisher maintenance date

Nodal ( Yes / No ) / Number of sites under nodal site

VIP ( Yes / No )

Macro,Micro,BSC,ODU

Compressor Horse power

Compressor Type

Number of racks

Rectifier Controller Type ( psc1000 / Acc / Emerson /Nokia / Lorain ……………… )

Compressor Model

Fereon Pressure

# of Modules

3 G ( Nokia )

All the BTS, BSC componentsCabient 1 ( 2BSU , 10 CTU , 2 MSI , 1 MCU, ….. )&Cabient 2 (, 10 CTU , 2 MSI , 1 MCU, … )

# of BTS's

# Of Battries

No of Air Conditions

Type of Air conditioning unit

Battery brand

Battery nominal voltage

Battery ampere hour

Number of strings