Sistema Electricidad(English)

7
www.witechusa.com Copyright ® 2012 All Rights reserved ELECTRICITY ANTI-TAMPERING SYSTEM WITECH USA electricity an-tampering system allows you to control and monitor with security metering to consumers which are non regulated, regulated and deregulated market. The an-tamper system is composed by enclosures speacialy for interior and exterior use and sends special alarms and reports. It also works with WIMETER soſtware for Automated Meter Reading (load profiles and events). It is composed by: One Magnec field sensor Over voltage protecon for the Modem. Backup baery Connectors for wiring sensors to the modem Main comunicaon cable between meter and modem 3G Modem with digital inputs and outputs (On/Off), flat antenna for gps and 3G and a power adapter. 12 Volts DC. Two door sensors One Inclinaon sensor One Electrostac sensor

Transcript of Sistema Electricidad(English)

Page 1: Sistema Electricidad(English)

www.witechusa.com Copyright ® 2012 All Rights reserved

ELECTRICITY ANTI-TAMPERING SYSTEM

WITECH USA electricity anti-tampering system allows you to control and monitor with security metering to consumers which are non regulated, regulated and deregulated market. The anti-tamper system is composed by enclosures speacialy for interior and exterior use and sends special alarms and reports. It also works with WIMETER software for Automated Meter Reading (load profiles and events). It is composed by:

One Magnetic field sensor

Over voltage protection for the Modem.

Backup battery

Connectors for wiring sensors to the modem

Main comunication cable between meter and modem

3G Modem with digital inputs and outputs (On/Off), flat antenna for gps and 3G

and a power adapter. 12 Volts DC.

Two door sensors

One Inclination sensor

One Electrostatic sensor

Page 2: Sistema Electricidad(English)

Un-authorized opening of enclosure door (door-sensor)Presence sensorInclination sensorElectrostatic sensorMagnetic field sensor

Tension disconnection phase A (1)Tension disconnection phase B (2)Tension disconnection phase C (3)Neutral disconnectionCurrent absence phase A (1)Current absence phase B (2)Current absence phase C (3)Energy consumption in kWReactive energy consumption in kVARhPower in kWPower in kVARPower in kVAMaximum Demand in kWCurrent phase A, B and C.Voltage in phases AB, BC, AC, AN, BN, CN

Alarms a gap in the meter clockBackup battery failureDate and time of events

Actaris SL700Actaris ACE6000ABB A1R – Almi – Alsi – ALmNansen S – SXLandis ZMG405EMH-ElgamaElster A1200 – A1800

Protocols listed: DLMS/COSEM, ANSI C, Modbus, DNP3, IEC 62056Future protocols: ABNT NBR

AIRCONFIG SOFTWARE

METERS SUPPORTED:REPORTS AND ALARMS:

Page 3: Sistema Electricidad(English)

SPECIFICATIONS AIRCON WT-GP1Hazardous Areas:

Dimensions:Housing Materials:Interface Connector:GPRS Antenna:Radio Frequency:GSM/GPRS/WCDMA Sensitivity:GSM/GPRS/WCDMATransmit Power:LEDS:LCD:

Complies Class 1, Div 2 Pending certification. Option: Class 1, Div. 1 165mm x 791mm x 35mm.Seamless Aluminium extrusion, Powder coated.Sealed 37 pins.Male SMA Connetor, 50ohm.Quad Band 850/900/1800/1900 Mhz.-108 db

33dBm +-2dBPower, RSSI, Voltage, Data, Link status.20x2 with backlight, Parameters and sleep mode programmable via Airconfig.

3G PACKET DATAHSDPA/WCDMA and Quad-Band GSM/GPRS/EDGE.CS1-CS4.PBCCH Support.RS232, RS485, USB CDC, ETHERNET, I2C and more.PPP, UDP, TCP/IP, AT, USB CDC.

Mode:Coding Schemes:Packet Channel:Application Interface:Host Protocols:

SIM ACCESSSim Acess: External -3V, Dual Sim

ENVIRONMENTOperating:Humidity:

-20°C to +80°CUp to 80% non-condensing

GPS FUNCTIONALITY

POWER Authorized DistribuitorDC Voltage:Sleep Mode:Tx Mode:Rx Mode:

5-30V4 uA500 mA (Maximum)350 mA

CONTROL AND ANALOGUE INPUTS / OUTPUTS1 Analogue output 0-5V dc, 4 analogue inputs 4-20mA or 0-5V controllable via Airconfig.

WITECH USA INC. Address: 20283 State Road 7, Suite 400 - Boca Raton, Florida.

Tel: (561) 883-8130 - Fax: (561) 883-812 9 Email: [email protected]

www.witechusa.com

Connector:Antenna:GPS Protocols:

SMA Female3.3V activeNMEA-0183, SIRF Binary

OVER THE AIR CONTROLI/O Control

Monitors signal strenght RSSI level, case temperature, 2 opto - isolated input voltage, 2 opto - isolated, digital output via Airconfig windows application.

GLOBALSTAR / SATELLITE TECHNICAL SPECIFICATIONSOperating Frequencies

Maximum transmit powerDC input voltage.

Power Consumption @5VDC input (estimated)

InterfacesUser Ports

Module Antenna Connectors

Temperature RangeModule Environment Conditions

Antenna Environment Conditions

CertificationsFCC, IC, CE, ANATEL

Transmit: 1610 MHz – 1626.5 MHzReceive: 2483.5 MHz – 2500 MHz+31dBm EIRP (passive antenna), +34 dBm (active antenna)+4.7V to 5.1V

22 pin Molex connector with pin-outs for data port, auxiliary port (control/NEMA), audio and powerUSB-B connector for data and diagnostics connectivity.Passive: TX SMA Female, RX SMA femaleActive: TX SMA male, RX SMA female.

State Typical0.650.5

3.65

ShutdownStandby Shutdown

OPERATIONAL

-22ºF to +140ºF (-30 to +60ºC), humidity 5% - 95% (under 40°C).

-40ºF to +185ºF(-40°C to +85°C), humidity 5% -95% (under 40°C).

NON-OPERATIONAL

-40ºF to +185ºF (-40°C to +85ºC), humidity 5% - 100% (under 40°C).

-40ºF to +185ºF(-40°C to +85°C), humidity 5% -95% (under 40°C).

Min0.00.52.2

Max1.01.15.0

UnitsmWWW

Page 4: Sistema Electricidad(English)

WIMETER (AUTOMATIC METER READING SOFTWARE) WIMETER ELECTRIC is a back-up software for Automatic Meter Reading that uses a complex encryption algorithm assuring the maximum security level of the information of historical data of customer billing. WIMETER automates the meter reading sending it to the billing software’s.

Main Characteristics:

Programed hourly and/or daily meter reading. Exports the readings to a .csv file. Supports electricity meters with protocols IEC 62056 (DLMS/COSEM), MODBUS, BSAP, HEXASCII. Protocol encryption in GSM or 3G networks exclusively WITECH WT-GP modems.

Page 5: Sistema Electricidad(English)

WIMETER (AUTOMATIC METER READING SOFTWARE)

Create Stations or groups of meters with the most relevant data for your enterprise.

Scheduler option for configuring which days, months or how often the meters are going to be automatically read by the WIMTER.

Minimum requirements for running the WIMETER in a PC:

Software: Microsoft .NET version 4.0 Windows XP or superior

Hardware Processor: 1 Ghz RAM: 512 MB Space in Hard Disk: - Windows 32 bit – 850 MB - Windows 64 bit – 2 GB

Page 6: Sistema Electricidad(English)

AUTOMATIC SCHEDULER GRID

See the automatic meter readings that are scheduled with their actual status in real-time. The user can see the successful percentage of readings and can stop the readings in each row with double click.

Page 7: Sistema Electricidad(English)