Simultaneously Reducing NOx and Slagging on a T-Fired Boiler Long Term Test Results
-
Upload
mohammad-imran-khan -
Category
Documents
-
view
7 -
download
0
description
Transcript of Simultaneously Reducing NOx and Slagging on a T-Fired Boiler Long Term Test Results
-
Page 1 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Simultaneously Reducing NOx and Slaggingon a T-Fired Boiler Long Term Test Results
Siemens Energy Inc.Advanced Burner Technologies Product Line
3040 US Highway 22 WestBranchburg, NJ 08876
-
Page 2 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Introduction
This presentation will describe the design, guarantee testing and long term testing of a tangentially fired low NOx combustion system.
The combustion system was installed at the Owensboro MunicipalUtilities (OMU) plant, Elmer Smith Unit #2.
-
Page 3 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Boiler and Required Guarantee Background
Fuel: Severely slagging midwesternbituminous coal
Operational Concerns:
Severe furnace slagging due to (1) High furnace heat release rate, (2) Low coal ash fusion temperatures
Furnace waterwall corrosion due to (1) Local reducing conditions and (2) High fuel sulfur content
Existing Boiler Information: 290 MW Single furnace Four burner levelsCCOFA
Guarantee Requirements: NOx guarantee: 308 mg/Nm3 CO:
-
Page 4 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Coal Analysis and Slagging Index
Sulfur, wt% 4.4Ash, wt% 21.3SiO2 40.6Al2O3 17.2Fe2O3 21.3CaO 6.7MgO 0.9K2O 1.9
Slagging Index Severe
-
Page 5 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Siemens Scope of Work
CFD modeling Fuel injector and combustion air OFA system Anti-corrosion and slagging system
Low NOx combustion equipment 16 new ABT Opti-Flow fuel injectors New combustion air buckets New one level SOFA system Anti-corrosion and slagging system
-
Page 6 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Burner Arrangement
-
Page 7 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Opti-FlowTM Low NOx BurnerT-Fired System Cut-Away
-
Page 8 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Low NOx Burner Nozzle
Heart of all Opti-Flow Low NOx burners
Produces 35% Lower NOx than early generation LNBs replaced by ABT and 60 to 70% below turbulent burners.
Open Nozzle, No Coking, Low Wear Geometry
AXIAL VANE
STABILIZER VANE
-
Page 9 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Derivation of Wall-Fired Technology to Tangentially-Fired Units
Fuel Injector for Wall-Fired Boiler
Fuel Injector for T-Fired Boiler
-
Page 10 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Opti-FlowTM Fuel Injector For OMU
-
Page 11 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Nozzle from Furnace Side
Cast Nozzle
Removable ErosionProtection Plug
Air Seal Assembly
NO Evidence ofErosion, Cracking
OrOverheating
After Two Years
-
Page 12 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Typical Nozzle After Two Years
No Evidence of Wear
-
Page 13 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Replaceable Central Deflector After 2 Years
-
Page 14 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
T Fired Burner after Five Years Continuous Operation
-
Page 15 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Opti-Flow OFA System
Minimize sub-stoichiometric burner operation
Utilize single level of ports with two on each wall
Optimize the following: De-NOx zone residence time Residence time in the burnout zone
-
Page 16 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
C
L
S
E
C
A
I
R
D
U
C
T
C
L
S
E
C
A
I
R
D
U
C
T
TAKEOFF FROM EXISTING SECONDARY AIR DUCT
NON-METALLIC EXPN JOINT-TYP
4' X 6' TYP
Opti-Flow OFA System
-
Page 17 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Opti-Flow Aerodynamic OFA Port
Single Stage Design
One Damper Controls Total Flow
Baffles Control Flow Pattern
No Swirl
Deep Penetration
Excellent Horizontal Mixing
High Reliability Only 1 Moving Part
-
Page 18 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Opti-Flow OFA Aerodynamic Penetration
-
Page 19 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Opti-Flow OFAs Effect On CO For ATangentially Fired Boiler
-
Page 20 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
CFD Deposition Model Results
0.002 kg/m2-s
0
0.002 kg/m2-s
0
Previous Baseline ABT Final Case Previous BaselineABT Final Case
Baseline BaselineSiemens Case Siemens Case
-
Page 21 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Case Study:Owensboro Municipal Utilities
300 MW T-Fired BoilerSingle Furnace
4%+ Sulfur - High Slagging CoalSiemens Scope: New Burners; Sofa System And Anti-Corrosion System
Original System Performance Long Term Test
NOx:
-
Page 22 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
NOx vs Load Results
0.2
0.3
0.4
0.5
150 200 250 300Load [MW ]
N
O
x
[
l
b
/
M
M
B
t
u
]
2.0
3.0
4.0
5.0
6.0
G
r
i
d
O
2
[
%
]
Grid O2
Baseline NOx
Post-Retrofit NOx
NOx Guarantee
-
Page 23 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
LOI Performance
0.6
0.98
0.67
1.32
0.97
0.86
0
0.2
0.4
0.6
0.8
1
1.2
1.4
150 225 285Load [MW]
L
O
I
[
%
]
BaselinePost-Retrofit
-
Page 24 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Slagging Improvements
Pre-Retrofit:Severe slagging of furnace wallsBurners unable to tilt due to slag build-upDropping load required every shift to shed slag
Post-Retrofit:Furnace walls nearly completely cleanBurners are capable of tiltingNo dropping of load required after months of operation
-
Page 25 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
Summary
A Siemens designed novel low NOx combustion system for tangentially fired units was implemented at OMUs Elmer Smith Plant, Unit #2.
Some technical challenges faced were: (1) high heat release furnace, (2) high sulfur, severe slagging coal.
Post Retrofit Results: NOx level of 287 mg/Nm3 CO emissions less than 100 ppm over the load range. Fly ash LOI less than 1% Severe furnace slagging practically eliminated
-
Page 26 April, 2012Copyright Siemens AG 2012. All rights reservedPROPRIETARY CONFIDENTIAL
BUSINESS INFORMATION
THANK YOU