SIMPLIFIED MODELS OF ILD AND SID DETECTORS: SIMULATIONS AND SCALED TEST BENCH @ ULB: Christophe...

20
SIMPLIFIED MODELS OF ILD AND SID DETECTORS: SIMULATIONS AND SCALED TEST BENCH @ ULB: Christophe Collette , David Tschilumba, Lionel Fueyo-Rosa @ SLAC: Marco Oriunno, Thomas Markiewicz, Kirk Bertsche [email protected]

Transcript of SIMPLIFIED MODELS OF ILD AND SID DETECTORS: SIMULATIONS AND SCALED TEST BENCH @ ULB: Christophe...

SIMPLIFIED MODELS OF ILD AND SID DETECTORS: SIMULATIONS

AND SCALED TEST BENCH

@ ULB: Christophe Collette, David Tschilumba, Lionel Fueyo-Rosa

@ SLAC: Marco Oriunno, Thomas Markiewicz, Kirk Bertsche

[email protected]

C. Collette, LCWS 12 (October 25, 2012)

2

CLIC final focus

C. Collette, LCWS 12 (October 25, 2012)

3

CMS Experiment (LHC tunnel)

[C. Collette et al. “Control strategies for the final focus of future linear particle collider” Nuclear Instruments and Methods in Physics Research Section A Vol. 684 (August 2012), pp. 7-17]

C. Collette, LCWS 12 (October 25, 2012)

4

Simplified model

Cantilever support

Random force

C. Collette, LCWS 12 (October 25, 2012)

5

Model of the technical noise

PSD of the random force F

C. Collette, LCWS 12 (October 25, 2012)

6

Solutions tested

1. Isolation

2. Damping 3. Stiffening

C. Collette, LCWS 12 (October 25, 2012)

7

Example of results

seismometer

C. Collette, LCWS 12 (October 25, 2012)

8

C. Collette, LCWS 12 (October 25, 2012)

Finite element model (Full scale)9

Resonances frequencies multiplied by 2

Active tendon

C. Collette, LCWS 12 (October 25, 2012)

Numerical results

Avantages :

Stiffness

Active damping

Alignment

10

C. Collette, LCWS 12 (October 25, 2012)

Scaled test bench (in production)11

Resonances frequencies multiplied by 2

Active tendon:

APA100M+BK8200

Active tendon

12

C. Collette, LCWS 12 (October 25, 2012)

Experimental set-up

13

C. Collette, LCWS 12 (October 25, 2012)

Divided by 30

Positioning:out of phase sinusoidal signals in the two vertical actuators:

Amplitude: 30 µmFrequency: 30 Hz

Active damping of all the modes

1

2

3

14

C. Collette, LCWS 12 (October 25, 2012)

Simplified model of the SiD

Additional features: QD0s and QF1s Detector tilt Beam dynamics Soil model Technical noise model

15

C. Collette, LCWS 12 (October 25, 2012)

Simplified model of the SiD

QF1 QD0 QD0 QF1

16

C. Collette, LCWS 12 (October 25, 2012)

Simulations

Integrated RMS of the random force

17

C. Collette, LCWS 12 (October 25, 2012)

Ground motion measurement at SLAC

18

C. Collette, LCWS 12 (October 25, 2012)

Power spectral densities

Without technical noise With technical noise

19

C. Collette, LCWS 12 (October 25, 2012)

Integrated RMS

Without technical noise With technical noise

QF1s play a big role; Technical noise is not very harmful

20

C. Collette, LCWS 12 (October 25, 2012)

Conclusions

Simplified model of the CLIC_ILD final focus, updated with

ground motion model from CMS

Proposal of active tie rods:

Improve the robustness to technical noise

Active structural damping

Positioning

Results validated on a scaled test bench

Simplified model of the SiD detector

QF1 plays a big role

Technical noise is not very harmful

Future work: Passive and active isolation of the QF1 and QD0