Significant changes to ACI 318-08 relative ... - S. K....

37
3 PCI Journal | Special Supplement Significant changes to ACI 318-08 relative to precast/ prestressed concrete: part 1 S. K. Ghosh Significant changes have been made since American Concrete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Structural Concrete (ACI 318-05) and Commentary (ACI 318R-05). 1 The changes in the new 2008 edition 2 are summarized in this paper. The intent of this article is to provide a summary of signifi- cant changes affecting conventionally reinforced concrete, precast concrete, and prestressed concrete (including post- tensioned concrete). This information should be useful to building officials, design engineers, practitioners, and the academic community. Only changes to chapters 1 through 8 of ACI 318-08 are discussed in part 1 of this article series. Changes beyond chapter 8 will be discussed in parts 2 and 3, which will appear in subsequent issues of the PCI Journal. Unlike previous releases of new ACI 318 editions, ACI’s Con- crete International did not publish a complete list of changes. Only a summary paper was published in the July 2007 issue of the magazine. 3 The changes were posted on the ACI website until August 15, 2007, when the public comment period ended. Pertinent discussion received by the August 15 deadline and the official response from ACI committee 318 will be pub- lished on ACI’s website. In response to public comments, the committee has made additional changes to ACI 318-08, which has not yet been published. ACI 318-08 will be the reference document for concrete de- sign and construction in the 2009 edition of the International Editor’s quick points n This first of three papers describes the changes from the 2005 edition to the 2008 edition of ACI 318, Build- ing Code Requirements for Structural Concrete and Commentary for chapters 1 through 8. n ACI 318 underwent a major revision with this version. n Parts 2 and 3 will follow in subsequent issues of the PCI Journal.

Transcript of Significant changes to ACI 318-08 relative ... - S. K....

Page 1: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

3PCI Journal | Specia l Supplement

Significant changes to ACI 318-08 relative to precast/ prestressed concrete: part 1S. K. Ghosh

Significant changes have been made since American Concrete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Structural Concrete (ACI 318-05) and Commentary (ACI 318R-05).1 The changes in the new 2008 edition2 are summarized in this paper.

The intent of this article is to provide a summary of signifi-cant changes affecting conventionally reinforced concrete, precast concrete, and prestressed concrete (including post-tensioned concrete). This information should be useful to building officials, design engineers, practitioners, and the academic community. Only changes to chapters 1 through 8 of ACI 318-08 are discussed in part 1 of this article series. Changes beyond chapter 8 will be discussed in parts 2 and 3, which will appear in subsequent issues of the PCI Journal.

Unlike previous releases of new ACI 318 editions, ACI’s Con-crete International did not publish a complete list of changes. Only a summary paper was published in the July 2007 issue of the magazine.3 The changes were posted on the ACI website until August 15, 2007, when the public comment period ended. Pertinent discussion received by the August 15 deadline and the official response from ACI committee 318 will be pub-lished on ACI’s website. In response to public comments, the committee has made additional changes to ACI 318-08, which has not yet been published.

ACI 318-08 will be the reference document for concrete de-sign and construction in the 2009 edition of the International

Editor’s quick points

n  This first of three papers describes the changes from the 2005 edition to the 2008 edition of ACI 318, Build-ing Code Requirements for Structural Concrete and Commentary for chapters 1 through 8.

n  ACI 318 underwent a major revision with this version.

n  Parts 2 and 3 will follow in subsequent issues of the PCI Journal.

Page 2: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI Journal4

ture, as used in section 1.3.3, may be taken as the surface temperature of the concrete. Commentary section R1.3.3 used to say: “however, during mixing and placing it is practical to measure the temperature of the mixture.”

It now says: “Surface temperatures may be deter-mined by placing temperature sensors in contact with concrete surfaces or between concrete sur-faces and covers used for curing, such as insulation blankets or plastic sheeting.”

Commentary section R1.1.9, “Provisions for Earthquake Resistance” (formerly section R1.1.8), has been completely rewritten with the introduction of SDC terminology into ACI 318. Table R1.1.9.1 (formerly table 1.1.8.3), which provides corre-spondence between the new terminology and the terminology used in legacy model codes (seismic performance categories, seismic zones) and in prior editions of ACI 318 (regions of low, moderate, and high seismic risk), has been updated.

Chapter 2: “Notation and Definitions”

Definitions that used to be located at the beginning of chapter 21—previously “Special Provisions for Seismic Design” and now titled “Earthquake-Resistant Structures”—have been transferred to section 2.2.

The definition of lightweight aggregate concrete now references ASTM C3307 and replaces “dry loose weight of 70 lb or less” with “loose bulk den-sity of 70 lb/ft3 or less, determined in accordance with ASTM C29.”8

The definition of building official (previously in section 1.2.3) has been moved to section 2.2.

All-lightweight and sand-lightweight concretes are now defined separately, whereas they used to be part of the definition of lightweight concrete. Normal-weight concrete is now also defined. In the defini-tion of lightweight concrete, “equilibrium density not exceeding 115 lb/ft3” has been replaced with “equilibrium density between 90 and 115 lb/ft3.”

The term contract documents is now defined in chapter 2.

A new definition for specified concrete cover has been added. The commentary to this definition points out that tolerances on specified concrete cover are provided in section 7.5.2.1.

Building Code (IBC),4 which will continue to reference ASCE 7-05.5

All section and chapter numbers used in this paper refer to those of ACI 318-08, unless otherwise noted.

Chapter 1: “General Requirements”

A new section 1.1.4 permits concrete members that fall within the scope of ACI 3326 (including cast-in-place footings; foundation walls; and slabs-on-ground for one- and two-family dwellings and multiple single-family dwellings, such as townhouses, and their accessory structures) to be designed and constructed in accordance with ACI 332, Requirements for Residential Concrete Construction, instead of ACI 318-08.

Section 1.1.8 clarifies that ACI 318 requirements do not apply to the composite design of structural concrete slabs construct-ed on stay-in-place composite steel decks. Section 1.1.8 spe-cifically states that ACI 318 requirements do apply to portions of such slabs designed as reinforced concrete. Commentary section R1.1.8.2 explains that the design of negative moment reinforcement to make a slab continuous is an example of when a portion of the slab design should conform to ACI 318 requirements.

A new section 1.1.9 requires that the seismic design category (SDC)4,5 of a structure be determined in accordance with the legally adopted general building code. It further requires that all structures, except those assigned to SDC A or otherwise exempted by the legally adopted general building code, must satisfy the applicable provisions of chapter 21.

The former section 1.2.3, which defined building official, has been deleted. A definition of this term is now found in section 2.2, where all definitions are located.

In section 1.3.2, which lists items to be included in inspection records, item (a) used to read: “Quality and proportions of concrete materials and strength of concrete.”

It now reads: “Delivery, placement, and testing reports docu-menting the quantity, location of placement, fresh concrete tests, and other tests of all classes of concrete mixtures.”

In commentary section R1.3.2, two substantive sentences have been added: “Some of the information regarding designated concrete materials on a project is often provided in a pre-construction submittal to the licensed design professional. For instance, concrete mixture ingredients and composition are often described in detail in the submittal and are subsequently identified by a mixture designation (reflected on a delivery ticket), that can also identify the placement location in the structure.”

Commentary section R1.3.3 clarifies that concrete tempera-

Page 3: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

reinforcing bars may conform to ASTM A615,15 ASTM A706,16 or ASTM A99617 type R, as before, or may now con-form to ASTM A955, Standard Specification for Deformed and Plain Stainless Steel Bars for Concrete Reinforcement, section 3.5.3.1.18 Commentary section R3.5.3.1 clarifies that stainless-steel bars are used in applications in which high corrosion resistance or controlled magnetic permeability are required. The physical and mechanical property requirements for stainless-steel bars under ASTM A955 are the same as those for carbon-steel bars under ASTM A615. Newly added section 3.5.3.3 states that deformed reinforcing bars conform-ing to ASTM A1035, Standard Specification for Deformed and Plain, Low-Carbon, Chromium, Steel Bars for Concrete Reinforcement,19 may now be used as transverse reinforce-ment as permitted by section 21.4.4 or as spiral reinforcement as permitted by section 10.9.3.

The upper limit of D-31 is placed on the size of deformed wire in section 3.5.3.5 because tests have shown that D-45 wire will achieve only about 60% of the bond strength in tension given by Eq. (12-1). Newly added section 3.5.3.10 now specifically permits the use of deformed stainless-steel wire and deformed and plain stainless-steel welded wire conforming to ASTM A1022, Standard Specification for Deformed and Plain Stain-less Steel Wire and Welded Wire for Concrete Reinforcement,20 as concrete reinforcement.

Headed studs and headed-stud assemblies conforming to ASTM A1044, Standard Specification for Steel Stud Assem-blies for Shear Reinforcement of Concrete,21 are now specifi-cally recognized by the added section 3.5.5. Added section 3.5.8 requires that steel used in discontinuous fiber reinforce-ment must conform to ASTM A820, Standard Specification for Steel Fibers for Fiber-Reinforced Concrete.22 It further requires that steel fibers be deformed to increase mechanical bond with the concrete and have a length-to-diameter ratio no less than 100.

New section 3.5.9 requires headed deformed bars to conform to ASTM A970, Standard Specification for Headed Steel Bars for Concrete Reinforcement.23 It further requires that obstruc-tions and interruptions of the bar deformations, if any, not extend more than 2d

b from the bearing face of the head, where d

b is the

diameter of the bar.

Fly ash or other pozzolans, ground-granulated blast-furnace slag, and silica fume have now been removed from section 3.6, “Admixtures,” because they are included in section 3.2, “Cementitious Materials.” ACI 318-05 section 3.6.2, which required that an admixture be shown capable of essentially maintaining the same composition and performance through-out the work as the product used in establishing concrete proportions in accordance with section 5.2, has been deleted. This is because it used to apply to fly ash or other pozzolans, ground-granulated blast-furnace slag, and silica fume, which are now considered cementitious materials. ACI 318-05 sec-tion 3.6.5, now section 3.6.4, has been rewritten as “Admix-

Design load combination is now defined.

A drop panel is now defined as "a projection below the slab used to reduce the amount of negative reinforcement over a column or a minimum re-quired slab thickness, and to increase the slab shear strength."

Important new definitions have been added for equilibrium density, headed deformed bars, and headed shear stud reinforcement. Commentary to the definition for headed deformed bars points out important differences between such bars and headed shear stud reinforcement.

The term registered design professional has been replaced with licensed design professional. Because registered design professional is the term used in the IBC, the ACI 318 definition for licensed design professional includes, “in other documents, also referred to as registered design professional.”

The definition for pedestal has been modified once again for clarity.

The term seismic design category is defined. Also, new definitions for shear cap, steel fiber-reinforced concrete, and work have been added.

Finally, definitions for special precast structural wall and special reinforced concrete structural wall were added. The term special structural wall is now defined, and it can be made of cast-in-place or precast concrete.

Chapter 3: “Materials”

Cementitious materials, rather than cements, are now defined in section 3.2. These include fly ash and natural pozzolans complying with ASTM C618,9 ground-granulated blast-furnace slag com-plying with ASTM C989,10 and silica fume com-plying with ASTM C1240,11 in addition to portland cement complying with ASTM C15012 and blended hydraulic cements complying with ASTM C595.13

Section 3.4 simply refers to ASTM C1602/C1602M14 for water used in mixing concrete. All the text contained in prior editions of ACI 318 was deleted.

Whereas reinforcement consisting of structural steel, steel pipe, or steel tubing was previously permitted by ACI 318, reinforcement consist-ing of discontinuous deformed steel fibers is now additionally permitted (section 3.5.1). Deformed

5PCI Journal | Specia l Supplement

Page 4: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI Journal6

tures for water reduction and setting time modification shall conform to ASTM C494.24 Admixtures for use in producing flowing concrete shall conform to ASTM C1017.”25

Table 1 lists the ASTM reference standards added to section 3.8.

Section 3.8.9 added a reference to Requirements for Resi-dential Concrete Construction (ACI 332-04)6 and section 3.8.10 added a reference to Acceptance Criteria for Special Unbonded Post-Tensioned Precast Structural Walls Based on Validation Testing (ITG 5.1).26

Chapter 4: “Durability Requirements”

Chapters 4 and 5 of earlier editions of ACI 318 were refor-matted in 1989 to emphasize the importance of considering durability requirements before selecting fc

' and the specified

concrete cover over the reinforcing steel. In ACI 318-08, the format of chapter 4 is extensively revised by introducing exposure categories and classes, with applicable durability requirements given for the various classes in a unified format.

Tables in chapter 4 have been modified due to the adoption of exposure categories and classes. The coverage of durabil-ity in ACI 318 has been reorganized to make it more parallel with the approach used in the codes of some other countries.

The restructuring of chapter 4 does not include any significant technical changes to the provisions included in ACI 318-05.

ACI 318 defines exposure categories and classes for concrete structures in section 4.2.1—specifically in tables 4.2.1.a through 4.2.1.d. Tables 2 through 5 are adapted from those tables and the commentary to section 4.2.1. Associated requirements for concrete relative to the exposure classes are provided in ACI 318 section 4.3.

Chapter 5: “Concrete Quality, Mixing, and Placing”

A new section 5.1.6 has been added, and it re-quires steel fiber–reinforced concrete to conform to ASTM C1116, Standard Specification for Fiber-Reinforced Concrete.27 The minimum fc

' for steel fiber–reinforced concrete is required to be 2500 psi (17 MPa), the same as that for conventionally reinforced concrete.

Because of the concern that material properties may change with time, a limit of 12 months has been imposed on the age of the historical data used to qualify mixture proportions under section 5.3,

Table 1. ASTM reference standards added to ACI 318-08, section 3.8

ASTM Standard TitleA820/A820M-06 Standard Specification for Steel Fibers for Fiber-Reinforced Concrete

A955/A955M-07A Standard Specification for Deformed and Plain Stainless-Steel Bars for Concrete Reinforcement

A970/A970M-06 Standard Specification for Headed Steel Bars for Concrete Reinforcement

A1022/A1022M-07 Standard Specification for Deformed and Plain Stainless Steel Wire and Welded Wire for Concrete Reinforcement

A1035/A1035M-07 Standard Specification for Deformed and Plain, Low-Carbon, Chromium, Steel Bars for Concrete Reinforcement

A1044/A1044M-05 Standard Specification for Steel Stud Assemblies for Shear Reinforcement of Concrete

C29/C29M-97 (revised 2003) Standard Test Method for Bulk Density (Unit Weight) and Voids in Aggregate

C231-04 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method

C1012-04 Standard Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution

C1116-06/C1116M-06 Standard Specification for Fiber-Reinforced Concrete

C1602/C1602M-06 Standard Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete

C1609/C1609M-06 Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam with Third-Point Loading)

Table 2. Exposure Category F based on freezing and thawing exposure

Class Description ConditionF0 Not applicable Concrete not exposed to freezing and thawing cycles

F1 ModerateConcrete exposed to freezing and thawing cycles and that may be occasionally exposed to moisture before freezing (for example, exterior walls, beams, girders, and slabs not in direct contact with soil)

F2 SevereConcrete exposed to freezing and thawing cycles and that is in continuous contact with moisture before freezing (for example, water tanks)

F3 Very severeConcrete exposed to freezing and thawing cycles, that is in continuous contact with moisture, and where expo-sure to deicing chemicals is anticipated (for example, parking structures in the northern United States)

Source: Data adapted from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) table 4.2.1 and commen-tary section R4.2.1.

Page 5: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

7PCI Journal | Specia l Supplement

and proportioning on the basis of field experience or trial mixtures or both is allowed.

Under section 5.3.3.2, the requirements that must be met by trial mixtures for concrete proportions established from such mixtures to be acceptable have been revised as indicated:

Requirement (b) of section 5.3.3.2 in 318-05 •used to read: “Trial mixtures having propor-tions and consistencies required for proposed work shall be made using at least three differ-ent water-cementitious materials ratios or ce-mentitious materials contents that will produce a range of strengths encompassing fcr

' .”

It now reads: “Trial mixtures with a range of proportions that will produce a range of com-pressive strengths encompassing fcr

' and meet

the durability requirements of chapter 4.”

Requirement (c) of ACI 318-08 was: “Trial mixtures •shall be designed to produce a slump within ±0.75 in. (19 mm) of maximum permitted, and for air-entrained con-crete, within ±0.5% of maximum allowable air content.”

It now reads: “Trial mixtures shall have slumps within the range specified for the proposed Work; for air-entrained concrete, air content shall be within the tolerance specified for the proposed Work.”

Requirement (d) of ACI 318-05 was: “For each water-•cementitious materials ratio or cementitious materials content, at least three test cylinders for each test age shall be made and cured in accordance with ASTM C192, Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory.28 Cylinders shall be tested at 28 days or at test age designated for determination of

Table 3. Exposure Category S based on sulfate exposure

Class DescriptionWater-soluble sulfate in soil, % by weight

Sulfate in water, ppm Commentary

S0 Not applicable SO4 < 0.10 SO4 < 150 Injurious sulfate attack not common

S1 Moderate 0.10 ≤ SO4 < 0.20 150 ≤ SO4 < 1500 sea water More critical value of measured water-soluble sulfate concentration in soil or the concentration of dissolved sulfate in water governs

S2 Severe 0.20 ≤ SO4 ≤ 2.00 1500 ≤ SO4 ≤ 10,000 Same as for S1

S3 Very severe SO4 > 2.00 SO4 > 10,000 Same as for S1

Source: Data adapted from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) table 4.2.1 and commentary section R4.2.1.Note: ppm = parts per million.

Table 4. Exposure Category P based on requirements for low permeability

Class Description Condition CommentaryP0 Not applicable Concrete not required to have low

permeability to water—

P1 Applicable Concrete required to have low permeability to water

When the permeation of water into concrete might reduce durability or affect the intended function of the structural element

Source: Data adapted from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) table 4.2.1 and commentary section R4.2.1.

Class Description Condition CommentaryC0 Not applicable Concrete that will be dry or protected from moisture

in serviceNo additional protection required against the corro-sion of reinforcement

C1 Moderate Concrete exposed to moisture but not to an external source of chlorides in service

C2 High Concrete exposed to moisture and to an external source of chlorides in service

For example, deicing chemicals, salt, brackish water, seawater, or spray from these sources

Source: Data adapted from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) table 4.2.1 and commentary section R4.2.1.

Table 5. Exposure Category C based on requirement for corrosion protection of reinforcement

Page 6: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI Journal8

a minimum time for the moisture gradient to dis-sipate. It now further explains that the maximum time between coring and testing is intended to ensure timely testing of cores when strength of concrete is in question. Newly added commen-tary further explains that to provide reproducible moisture conditions that are representative of in-place conditions, a common moisture con-ditioning procedure that permits dissipation of moisture gradients is now prescribed for cores. ASTM C42 permits the specifier of tests to modify the default duration of moisture condi-tioning before testing.

New section 5.6.6.1 requires that steel fiber–re-inforced concrete beams be tested in accordance with ASTM C1609, Standard Test Method for Flexural Performance of Fiber-Reinforced Con-crete (Using Beam with Third-Point Loading).30

New section 5.6.6.2 states that steel fiber–rein-forced concrete is to be considered acceptable for shear resistance if three given conditions are satisfied. The commentary points out that these performance criteria are based on results from flexural tests conducted on steel fiber–reinforced concrete beams with fiber types and contents similar to those used in the tests of beams that served as the basis for newly added section 11.4.6.1(f).

Chapter 6: “Formwork, Embedments, and Con-struction Joints”

“Embedments” has replaced “Embedded Pipes” in the title of the chapter. Throughout the chap-ter, “conduits and pipes embedded in concrete” or “conduits, pipes, and sleeves embedded in concrete” have been changed to “embedments in concrete.”

In section 6.4.7, shear caps, as defined in section 2.2, have been added to the list of items (beams, girders, haunches, drop panels, and capitals) that must be placed monolithically as part of a slab system.

Commentary section R6.3.2 now points out that section 6.3.2 prohibits calcium chloride or any admixture containing chloride from being used in concrete with aluminum embedments.

Chapter 7: “Details of Reinforcement”

To permit a more consistent application of toler-

fc' .”

It now reads: “For each trial mixture, at least two 6 in. × 12 in. (150 mm × 300 mm) or three 4 in. × 8 in. (100 mm × 200 mm) cylinders shall be made and cured in accor-dance with ASTM C192. Cylinders shall be tested at 28 days or at test age designated for fc

' .”

Requirements (e) and (f) of ACI 318-05 read: “From •results of cylinder tests a curve shall be plotted showing the relationship between water-cementitious materials ratio or cementitious materials content and compressive strength at designated test age. Maximum water-cementi-tious materials ratio or minimum cementitious materials content for concrete to be used in proposed Work shall be that shown by the curve to produce fc

' required by 5.3.2, unless a lower water-cementitious materials ratio or higher strength is required by chapter 4.”

All of this has been replaced by a new item (e), which reads: “The compressive strength results, at designated test age, from the trial mixtures shall be used to establish the composition of the concrete mixture proposed for the Work. The proposed concrete shall achieve an average compressive strength as required in 5.3.2 and satisfy the applicable durability criteria of chapter 4.”

It should be noted that ACI 318 has now recognized the use of three 4 in. × 8 in. (100 mm × 200 mm) cylinders as equivalent to the use of two 6 in. × 12 in. (150 mm × 300 mm) cylinders. This change is also reflected in section 5.6.2.4. The commentary clarifies that the confidence level of the average strength is preserved this way because 4 in. × 8 in. cylinders tend to have about 20% higher within-test variability than 6 in. × 12 in. cylinders. The commentary also points out that more than the minimum number of specimens may be desirable to allow for discarding an outlying individual cylinder strength in accordance with ACI 214R.29

Commentary section R5.3.3.2 provides new commentary on items (b), (d), and (e) under section 5.3.3.2.

ACI 318-05 section 5.6.5.3 reads: “Cores shall be prepared for transport and storage by wiping drilling water from their surfaces and placing the cores in watertight bags or containers immediately after drilling.”

The section now reads: “Cores shall be obtained, moisture conditioned by storage in watertight bags or containers, transferred to the laboratory, and tested in accordance with ASTM C42.” A newly added sentence requires that the specifier of tests referenced in ASTM C4231 be a licensed design professional.

Commentary section R5.6.5 previously explained that the restriction on the commencement of core testing provides

Page 7: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

9PCI Journal | Specia l Supplement

ances in ACI 318 and other ACI documents, speci-fied cover has replaced minimum cover throughout chapter 7. This change affects sections 7.7.1, 7.7.2, 7.7.3, 7.7.4, 7.7.5, and 7.7.6.

Newly added section 7.7.5 requires that for headed shear-stud reinforcement, specified concrete cover for the heads or base rails shall not be less than that required for the reinforcement in the type of member in which the headed shear–stud reinforce-ment is placed.

In section 7.7.6 on corrosive environments, “dense-ness and nonporosity of protecting concrete shall be considered” has been replaced by “the pertinent requirements for concrete based on applicable exposure categories in chapter 4 shall be met.”

In section 7.13, “Requirements for Structural Integrity,” changes have been made to the anchor-age and splice requirements for structural integrity reinforcement. Continuous top and bottom struc-tural reinforcement is now required to pass through the column core. Also, the types of transverse reinforcement used to enclose structural integrity reinforcement in perimeter beams are more clearly specified.

Section 7.13.2.1 of ACI 318-05 required that, in joist construction, at least one bottom bar be con-tinuous or spliced with a Class A tension splice or a mechanical or welded splice. A Class B tension splice is now required. Whereas ACI 318-05 re-quired that this bar be terminated at noncontinuous supports with a standard hook, it is now required that the bar be anchored to develop f

y at the face of

the support using a standard hook satisfying section 12.5 or a headed deformed bar satisfying section 12.6 at noncontinuous supports.

Section 7.13.2.2 now requires beams along the perimeter of the structure to have continuous reinforcement passing through the region bound by the longitudinal reinforcement of the column. At noncontinuous ends, this reinforcement is required to be anchored to develop f

y at the face of the sup-

port using standard hooks satisfying section 12.5 or headed, deformed bars satisfying section 12.6.

Section 7.13.2.3 now requires that all continuous reinforcement required by section 7.13.2.2 for pe-rimeter beams be enclosed by transverse reinforce-ment of the type specified in section 11.5.4.1 for torsion. The transverse reinforcement is required to be anchored as specified in section 11.5.4.2. It is spelled out that the transverse reinforcement need not be extended through the column.

Where splices are required to satisfy section 7.13.2.2, the top reinforcement is required to be spliced at or near midspan and the bottom reinforcement at or near the support. Splices are required to be Class B tension splices or mechanical or welded splices satisfying section 12.14.3, which was section 7.13.2.4 in ACI 318-05.

Any continuous positive-moment reinforcement (other than that in perimeter beams) provided in compliance with the re-quirements of section 7.13.2.5 is required to pass through the region bound by the longitudinal reinforcement of the column. Where such reinforcement is spliced, the splices are required to be Class B tension splices or mechanical or welded splices. At noncontinuous supports, such reinforcement is required to be anchored to develop f

y at the face of the support using

standard hooks satisfying section 12.5 or headed, deformed bars satisfying section 12.6.

A new section 7.13.2.7 refers the ACI 318 user to sections 18.12.6 and 18.12.7 for newly added structural integrity re-quirements for prestressed, two-way slabs.

Terms such as structural engineer, registered engineer, registered architect, registered design professional, engineer, designer, engineer, and architect have all been either replaced with licensed design professional or eliminated. The corre-sponding term in the IBC4 is registered design professional.

Design requirements for earthquake-resistant structures have been rewritten in terms of SDC. The prior terminology of regions of low, moderate, and high seismic risk is gone. This change makes ACI 318 terminology the same as that used in the IBC and the ASCE 7 Standard Minimum Design Loads for Buildings and Other Structures5 (since its 1998 edition). Because the IBC has emerged as the one model building code for the entire country on which the legal codes by most legal jurisdictions (such as cities, counties, and states) are based, this is a sensible and timely change. The IBC will no longer have to provide an interface between its own terminology and that of ACI 318, as it has in the past.

Chapter 8: “Analysis and Design—General Considerations”

A new commentary section R8.2.4 has been added. It explains that the restraint of shrinkage and temperature effects can cause significant internal forces and displacements. In cases of restraint, shrinkage and temperature reinforcement require-ments may exceed flexural reinforcement requirements.

In the title of section 8.4, “Redistribution of Negative Mo-ments in Continuous Flexural Members,” the word negative has been dropped. The section has been modified to permit moments to be redistributed away from positive-moment sec-tions as well as negative-moment sections.

Page 8: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI Journal10

service-level lateral forces, or more detailed analy-ses must be carried out. Member properties greater than gross section properties must not be used in determining lateral deflections under service-level lateral forces.

References

1. American Concrete Institute (ACI) Commit-tee 318. 2005. Building Code Requirements for Structural Concrete (ACI 318-05) and Commen-tary (ACI 318R-05). Farmington Hills, MI: ACI.

2. ACI Committee 318. 2008. Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08). Farmington Hills, MI: ACI.

3. Wight, J. K. 2007. Changes to Expect in the 2008 Edition of the ACI Building Code (ACI 318-08). Concrete International, V. 29, No. 7 (July): pp. 49–53.

4. International Code Council. 2006. Inter-national Building Code. Washington, DC: International Code Council.

5. Structural Engineering Institute. 2005. Mini-mum Design Loads for Buildings and Other Structures. Reston, VA: American Society of Civil Engineers (ASCE).

6. ACI Committee 332. 2004. Requirements for Residential Concrete Construction (ACI 332-04) and Commentary (ACI 332R-04). Farmington Hills, MI: ACI.

7. American Society for Testing and Materials (ASTM) Subcommittee C09.21. 2005. Stan-dard Specification for Lightweight Aggregates for Structural Concrete. ASTM C330-05. West Conshohocken, PA: ASTM.

8. ASTM Subcommittee C09.20. 1997. Stan-dard Test Method for Bulk Density (Unit Weight) and Voids in Aggregate. ASTM C29/C29M-97. West Conshohocken, PA: ASTM.

9. ASTM Subcommittee C09.24. 2005. Stan-dard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Con-crete. ASTM C618-05. West Conshohocken, PA: ASTM.

10. ASTM Subcommittee C09.27. 2006. Stan-dard Specification for Ground Granulated

Before its 2008 edition, ACI 318 addressed moment redis-tribution by permitting an increase or decrease of factored negative moments above or below elastically calculated values, within a 20% limit. A decrease in the negative mo-ment strength to 20% below the factored negative moment at the support might result in a change in the bending moment at the section of maximum positive bending moment by much more than 20%, with significant inelastic behavior probably accompanying this increase. ACI 318-08 places the same 20% limitation on changes in both positive and negative bending moments.

A new section 8.6, “Lightweight Concrete,” was added to bring about consistent treatment of lightweight concrete throughout ACI 318. The factor λ reflects the lower tensile strength of lightweight concrete, which may result in lower shear strength, frictional resistance, splitting resistance, bond between concrete and reinforcement, and increased develop-ment length, compared with the corresponding properties of normalweight concrete of the same compressive strength.

In the first of two approaches to determine λ, the tensile strength of lightweight concrete is assumed to be a fixed fraction of the tensile strength of normalweight concrete. The multipliers are based on tests of many types of structural light-weight aggregate. The second approach is based on laboratory tests to determine the splitting tensile strength f

ct of light-

weight concrete. That of normalweight concrete is assumed to be 6.7 fc

' . λ is then equal to fct/6.7 fc

' ≥ 1.

A new section 8.8, “Effective Stiffness to Determine Lateral Deflections,” was added. Section 8.8.2 requires that the lateral deflections of reinforced-concrete building systems resulting from factored lateral forces be determined by either:

a detailed analysis considering the reduced stiffness of all •members under the loading conditions;

a linear analysis using (a) section properties defined in •section 10.10.4(a) through (c) (section 10.10 deals with slenderness effects in compression members) or (b) 50% of stiffness values based on gross section properties.

Where two-way slabs without beams form part of the lateral-force-resisting system, section 8.8.3 permits lateral deflec-tions resulting from factored lateral forces to be computed using linear analysis. The stiffness of slab members must be defined by a model in substantial agreement with the results of comprehensive tests and analysis, and the stiffness of other members must be as defined in section 8.8.2. In other words, no empirical stiffness assumptions are given for the slab members themselves.

According to section 8.8.1, linear analysis with member stiff-ness determined using 1.4 times the flexural stiffness defined in sections 8.8.2 and 8.8.3 may be used to determine lateral deflections of reinforced-concrete building systems under

Page 9: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

11PCI Journal | Specia l Supplement

Stainless Steel Wire and Welded Wire for Concrete Re-inforcement. ASTM A1022/A1022M-06. West Consho-hocken, PA: ASTM.

21. ASTM Subcommittee A01.05. 2005. Standard Specifi-cation for Steel Stud Assemblies for Shear Reinforcement of Concrete. ASTM A1044/A1044M-05. West Consho-hocken, PA: ASTM.

22. ASTM Subcommittee A01.05. 2006. Standard Specifi-cation for Steel Fibers for Fiber-Reinforced Concrete. ASTM A820/A820M-06. West Conshohocken, PA: ASTM.

23. ASTM Subcommittee A01.06. 2006. Standard Specifica-tion for Headed Steel Bars for Concrete Reinforcement. ASTM A970/A970M-06. West Conshohocken, PA: ASTM.

24. ASTM Subcommittee C09.23. 2005. Standard Specifi-cation for Chemical Admixtures for Concrete. ASTM C494/C494M-05a. West Conshohocken, PA: ASTM.

25. ASTM Subcommittee C09.23. 2007. Standard Specifi-cation for Chemical Admixtures for Use in Producing Flowing Concrete. ASTM C1017/C1017M-07. West Conshohocken, PA: ASTM.

26. ACI Innovation Task Group 5. Forthcoming. Acceptance Criteria for Special Unbonded Post-Tensioned Precast Walls Based on Validation Testing and Commentary. ACI ITG 5.1. Farmington Hills, MI: ACI.

27. ASTM Subcommittee C09.42. 2006. Standard Speci-fication for Fiber-Reinforced Concrete and Shotcrete. ASTM C1116/C1116M-06. West Conshohocken, PA: ASTM.

28. ASTM Subcommittee C09.61. 2006. Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory. ASTM C192/C192M-06. West Consho-hocken, PA: ASTM.

29. ACI Committee 214. 2002. Evaluation of Strength Test Results of Concrete (ACI 214-02) and Commentary (ACI 214R-02). Farmington Hills, MI: ACI.

30. ASTM Subcommittee C09.42. 2006. Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam with Third-Point Loading). ASTM C1609/C1609M-06. West Conshohocken, PA: ASTM.

31. ASTM Subcommittee C09.61. 2004. Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete. ASTM C42/C42M-04. West Conshohocken, PA: ASTM.

Blast-Furnace Slag for Use in Concrete and Mortars. ASTM C989-06. West Conshohock-en, PA: ASTM.

11. ASTM Subcommittee C09.24. 2005. Stan-dard Specification for Silica Fume Used in Cementitious Materials. ASTM C1240-05. West Conshohocken, PA: ASTM.

12. ASTM Subcommittee C01.10. 2005. Stan-dard Specification for Portland Cement. ASTM C150-05. West Conshohocken, PA: ASTM.

13. ASTM Subcommittee C01.10. 2007. Standard Specification for Blended Hydraulic Cements. ASTM C595-07. West Conshohocken, PA: ASTM.

14. ASTM Subcommittee C09.40. 2006. Standard Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete. ASTM C1602/C1602M-06. West Consho-hocken, PA: ASTM.

15. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforce-ment. ASTM A615/A615M-06a. West Con-shohocken, PA: ASTM.

16. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Rein-forcement. ASTM A706/A706M-06a. West Conshohocken, PA: ASTM.

17. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Rail-Steel and Axle-Steel Deformed Bars for Concrete Rein-forcement. ASTM A996/A996M-06a. West Conshohocken, PA: ASTM.

18. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Deformed and Plain Stainless-Steel Bars for Concrete Reinforce-ment. ASTM A955/A955M-06a. West Con-shohocken, PA: ASTM.

19. ASTM Subcommittee A01.05. 2006. Standard Specification for Deformed and Plain, Low-carbon, Chromium, Steel Bars for Concrete Reinforcement. ASTM A1035/A1035M-06. West Conshohocken, PA: ASTM.

20. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Deformed and Plain

Page 10: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI Journal12

Notation

db = nominal diameter of bar, wire, or prestressing strand

fc'

= specified compressive strength of concrete

fcr'

= required average compressive strength of concrete

fct = average splitting tensile strength of lightweight concrete

fy = specified yield strength of reinforcement

λ = modification factor reflecting the reduced mechanical properties of lightweight concrete, all relative to nor-malweight concrete of the same compressive strength

About the author

S. K. Ghosh, PhD, FPCI, is president of S. K. Ghosh Associates Inc. in Palatine, Ill.

Synopsis

Significant changes have been made since American Concrete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Struc-tural Concrete (ACI 318-05) and Commentary (ACI 318R-05). The changes in the upcoming 2008 edition are summarized in this paper. In addition to changes affecting conventionally reinforced concrete, provisions affecting precast/prestressed

concrete, including post-tensioned concrete, are enumerated. Only changes to chapters 1 through 8 of ACI 318-08 are discussed in this article.

Keywords

ACI 318, codes, structural concrete.

Reader comments

Please address any reader comments to PCI Journal editor-in-chief Emily Lorenz at [email protected] or Precast/Prestressed Concrete Institute, c/o PCI Journal, 209 W. Jackson Blvd., Suite 500, Chicago, IL 60606.

Page 11: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S3PCI Journal | Specia l Supplement

Editor’s quick points

n  This second of three papers describes the changes from the 2005 edition to the 2008 edition of ACI 318, Building Code Requirements for Structural Concrete and Commentary, for chapters 9 through 20.

n  ACI 318 underwent a major revision with this version.

n  Part 3 will follow in a subsequent issue of the PCI Journal.

Significant changes to ACI 318-08 relative to precast/ prestressed concrete: Part 2S. K. Ghosh

Significant changes have been made since American Con-crete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Structural Concrete (ACI 318-05) and Commentary (ACI 318R-05).1 The changes in the new 2008 edition2 are summarized in this paper.

The intent of this article is to provide a summary of significant changes affecting conventionally reinforced concrete, precast concrete, and prestressed concrete (in-cluding post-tensioned concrete). This information should be useful to building officials, design engineers, practitio-ners, and the academic community. Changes to chapters 1 through 8 of ACI 318-08 were discussed in part 1 of this article series, published as a member supplement to the March–April 2008 issue of the PCI Journal. Changes to chapter 9 through 20 of ACI 318-08 are discussed in this part 2 of the article series. Changes to chapter 21 and the appendices will be discussed in part 3, which will appear in a subsequent issue of the PCI Journal.

ACI 318-08 will be the reference document for concrete design and construction in the 2009 edition of the Inter-national Building Code (IBC),3 which will continue to reference ASCE 7-05.4

All section and chapter numbers used in this paper refer to those of ACI 318-08 unless otherwise noted.

Page 12: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS4

Members.” The slenderness provisions are reorganized to reflect “current practice where second-order effects are considered primarily using computer analysis techniques,” while the style of presentation used by ACI 318 since 1971 is retained. The moment magnifier method is also retained as an alternate procedure.

Section 10.10.1 permits slenderness effects to be neglected

"for compression members not braced against sidesway when:

klu

r! 22

"

and

"for compression members braced against sidesway when:

klu

r! 34"12

M1

M2

#

$%&

'(! 40 "

where

k = effective length factor

lu = unsupported length

r = radius of gyration

M1 = smaller factored end moment

2 = larger factored end moment

M1/M

2 = positive if a compression member is bent in

single curvature

A new feature permits a compression member to be con-sidered braced against sidesway when “bracing elements have a total stiffness, resisting lateral movement of that story, of at least 12 times the gross stiffness of the columns within the story.”

Section 10.10.2 requires that when slenderness effects are not neglected as permitted by section 10.10.1, “the design of compression members, restraining beams, and other supporting members be based on the factored forces and moments from a second-order analysis satisfying [section] 10.10.3, 10.10.4, or 10.10.5.”

Section 10.10.3 is titled “Nonlinear Second-Order Analy-sis,” section 10.10.4 contains requirements for elastic second-order analysis, and section 10.10.5 details mo-ment magnification procedure. The members being discussed are also required to satisfy sections 10.10.2.1 and 10.10.2.2. Section 10.10.2.1 requires that second-order effects in compression members, restraining beams, or

Chapter 9: “Strength and Serviceability Requirements”

The new commentary section, R9.2.1(a), provides valuable and much-needed clarification. It points out that the load-factor modification of section 9.2.1(a) is different from the live-load reduction based on the loaded area that is typi-cally allowed in the legally adopted general building code. The live-load reduction in the code adjusts the nominal load L. The lesser load factor in section 9.2.1(a) reflects the reduced probability of the joint occurrence of maximum values of multiple transient loads at the same time. The reduced live loads specified in the legally adopted general building code can be used simultaneously with the 0.5 load factor specified in section 9.2.1(a).

In section 9.3.2.2, the strength-reduction factor for spi-rally reinforced columns was increased from 0.70 to 0.75. Commentary section R9.3.2 notes that this increase is part-ly due to the superior performance of spirally reinforced columns when subjected to excessive loads or extreme excitations5 and is partly due to new reliability analyses.6

The -factor modifications of section 9.3.4(a)–(c) are now also applicable to structures that rely on intermediate precast concrete structural walls to resist earthquake effects in seismic design categories (SDC) D, E, or F. Previously, the modifications applied only to structures that rely on special moment frames or special structural walls to resist earthquake effects.

In section 9.3.5, the -factor for plain concrete was in-creased from 0.55 to 0.60. As stated in commentary section R9.3.5, this is partly due to recent reliability analysis and a statistical study of concrete properties.6

The first paragraph of section R9.3.4 of ACI 318-05 was eliminated. In section R9.4, it is clarified that the maxi-mum specified yield strength of nonprestressed reinforce-ment f

y in section 21.1.5 is 60,000 psi (420 MPa) in special

moment frames and special structural walls.

Chapter 10: “Flexure and Axial Loads”

“For a compression member with a cross section larger than required by considerations of loading,” section 10.8.4 permits the minimum reinforcement to be based on a reduced effec-tive area A

g not less than one-half the total area. ACI 318-05

used to state that the provision does not apply in regions of high seismic risk. ACI 318-08 now states that this provision does “not apply to special moment frames or special structural walls designed in accordance with chapter 21.”

The most significant change in chapter 10 is a rewriting of sections 10.10 through 10.13 of ACI 318-05 into the new section 10.10, “Slenderness Effects in Compression

Page 13: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S5PCI Journal | Specia l Supplement

other structural members not exceed 40% of the moment due to first-order effects. Section 10.10.2.2 requires that second-order effects “be considered along the length of compression members.” This can be done using the non-sway moment magnification procedure outlined in section 10.10.6.

Section 10.10.4 on elastic second-order analysis includes new equations (10-8) and (10-9), which provide more-refined values of EI considering axial load, eccentricity, reinforcement ratio, and concrete compressive strength, as presented in the two Khuntia and Ghosh ACI Structural Journal articles.7,8

Commentary section R10.13.8, “Tie Reinforcement around Structural Steel Core,” which was section R10.16.8 in ACI 318-05, used to state:

Concrete that is laterally confined by tie bars is likely to be rather thin along at least one face of a steel core section. Therefore, complete interaction between the core, the concrete, and any longitudinal reinforcement should not be assumed. Concrete will probably separate from smooth faces of the steel core. To maintain the concrete around the structural steel core, it is reason-able to require more lateral ties than needed for ordi-nary reinforced concrete columns. Because of probable separation at high strains between the steel core and the concrete, longitudinal bars will be ineffective in stiffen-ing cross sections even though they would be useful in sustaining compression forces.

This text has now been replaced with, “Research has shown that the required amount of tie reinforcement around the structural steel core is sufficient for the longi-

tudinal steel bars to be included in the flexural stiffness of the composite column.”9

Chapter 11: “Shear and Torsion”

The revisions to achieve a consistent treatment of light-weight concrete throughout ACI 318 (see discussion of section 8.6 in “Significant Changes to ACI 318-08 Relative to Precast/Prestressed Concrete: Part 1”10) have led to the deletion of section 11.2 of ACI 318-05. The revisions to ACI 318 also affect several of the equations in chapter 11. Those equations are found in sections 11.2, “Shear Strength Provided by Concrete for Nonprestressed Members”; 11.3, “Shear Strength Provided by Concrete for Prestressed Members”; 11.5.1, “Threshold Torsion”; 11.5.2, “Calculation of Factored Torsional Moment”; 11.9, “Provisions for Walls”; and 11.11, “Provisions for Slabs and Footings”.

In addition, in section 11.6.4.3 (11.6 is the section on shear friction), λ = 0.85 for sand-lightweight concrete was changed to “Otherwise, λ shall be determined based on volumetric proportions of lightweight and normalweight aggregates as specified in [section] 8.6.1, but shall not exceed 0.85.” Although the equations in the sections noted previously have different appearances, there have not been any significant changes related to the shear strength of structural members made of lightweight concrete.

Significant changes were made to the list of members in sec-tion 11.4.6.1 for which minimum shear reinforcement is not required where V

u exceeds 0.5V

c. Solid slabs, footings, and

joists are excluded from the minimum shear-reinforcement

Figure 1. Stud rails are used as slab shear reinforcement. Photo courtesy of Decon U.S.A. Inc.

Page 14: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS6

lines of headed shear stud reinforcement.”

Both the amount of shear assigned to the concrete Vc and

the nominal shear strength Vn = V

c + V

s are permitted to be

larger for headed stud assemblies than for other forms of slab or footing shear reinforcement at 3 fc

' bod and

8 fc' b

od, respectively. Section 11.11.5.1 clarifies that in

the calculation of Vd = A

v fyd

/s, Av is equal to the “cross-sec-

tional area of all the shear reinforcement on one peripheral line that is approximately parallel to the perimeter of the column section, where s is the spacing of the peripheral lines of headed shear stud reinforcement.”

Commentary section R11.11.5.1 clarifies that “when there is unbalanced moment transfer, the design must be based on stresses. The maximum shear stress due to a combina-tion of V

u and the fraction of unbalanced moment γ

vM

u

should not exceed vn, where v

n is taken as the sum of

3λ fc' and A

v fyt

/(bos).”

“The specified spacings between peripheral lines of shear reinforcement [Fig. 2] are justified by experiments.”18 Commentary section R11.11.5.2 cautions that the “clear spacing between the heads of the studs should be adequate to permit placing of the flexural reinforcement.”

Chapter 12: “Development and Splices of Reinforcement”

A new section 12.1.3 was added. The section specifi-cally calls designers’ attention to the structural-integrity requirements in section 7.13. There was concern within ACI Committee 318 that many designers were simply not aware of these requirements, though they have existed since the 1989 edition of ACI 318.

In all of the equations for development length of deformed bars and deformed wire in tension and compression, in sections 12.2.2 and 12.2.3, respectively, the lightweight-aggregate factor λ was moved from the numerator to the denominator. At the same time, in section 12.2.4(d), λ = 1.3 was replaced by “λ shall not exceed 0.75 unless f

ct is

specified (see [section] 8.6.1).” All of this is consistent with the definition of λ in section 8.6 and is explained clearly in commentary section R12.2.4.

Before ACI 318-08, Eq. (12-2) for Ktr included the yield

strength of the transverse reinforcement fyt. The current ex-pression assumes that f

yt = 60 ksi (414 MPa) and includes

only the area and the spacing of the transverse reinforce-ment and the number of bars being developed or lap spliced. This is because tests have shown that transverse reinforcement rarely yields during bond failure.

By far the most significant change in chapter 12 is the introduction of section 12.6, “Development of Headed and Mechanically Anchored Deformed Bars in Tension.” The

requirement because there is a “possibility of load sharing between weak and strong areas.” Section 11.4.6.1, under item (a), has now clarified that the slabs must be solid. Based on experimental evidence,11 a new limit on the depth of hol-low-core units was established in item (b) of section 11.4.6.1.

“Research has shown that deep, lightly reinforced one-way slabs and beams, particularly if constructed with high-strength concrete, or concrete with a small coarse aggre-gate size, may fail at shear demands less than V

c computed

using Eq. (11-3) especially when subjected to concentrated loads.”12–14 Because of this, “the exclusion for certain beam types in 11.4.6.1(e) is restricted to cases in which the total depth h does not exceed 24 in.”

Commentary section R11.4.6.1 further advises that “for beams where

fc' is greater than 7000 psi, consideration

should be given to providing minimum shear reinforcement when h is greater than 18 in. and V

u is greater than 0.5V

c.”

The new exception in item (f) in section 11.4.6.1 provides a design alternative to the use of shear reinforcement, as defined in section 11.4.1.1, for members with longitudinal flexural reinforcement in which

fc' does not exceed 6000

psi, h is not greater than 24 in., and Vu does not exceed

2 fc' b

wd. Fiber-reinforced concrete beams with hooked

or crimpled steel fibers in dosages greater than or equal to 100 lb/yd3 (59 kg/m3) “have been shown through laborato-ry tests to exhibit shear strengths larger than 3.5 fc

' bwd.”15

Commentary section R11.4.6.1(f) points out that the use of steel fibers as shear reinforcement is not recommended when corrosion of fiber reinforcement is of concern.

In section 11.6.5, the upper limit on the nominal shear-fric-tion strength V

n was significantly increased for both mono-

lithically placed concrete and concrete placed against inten-tionally hardened concrete. Commentary section R11.6.5 points out that the increase is justified in view of test data.16,17 Section 11.6.5 now clarifies that if a lower-strength concrete is cast against a higher-strength concrete, the value of

fc'

used to evaluate Vn must be the

fc' for the lower-strength con-

crete. The increase in the upper limit on the nominal shear-friction strength is also reflected in section 11.8.3.2.1 (part of section 11.8, “Provisions for Brackets and Corbels”).

One of the most significant changes in chapter 11 is the addition of code requirements to permit the use of headed stud assemblies as shear reinforcement in slabs and foot-ings (section 11.11.5). “Using shear stud assemblies, as shear reinforcement in slabs and footings, requires specify-ing the stud shank diameter, the spacing of the studs, and the height of the assemblies for the particular applications” (Fig. 1). Tests18 have shown that “vertical studs mechani-cally anchored as close as possible to the top and bottom of slabs are effective in resisting punching shear. . . . Com-pared with a leg of a stirrup having bends at the ends, a stud head exhibits smaller slip, and thus results in smaller shear crack widths. The improved performance results in larger limits for shear strength and spacing between peripheral

Page 15: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S7PCI Journal | Specia l Supplement

bearing strength provisions of [section] 10.4.19,20 Appendix D contains provisions for headed anchors related to the individual failure modes of concrete breakout, side-face blowout, and pullout, all of which were considered in the formulation of [section] 12.6.2. The restriction that the concrete must be normalweight, the maximum bar size of no. 11, and the upper limit of 60,000 psi on f

y are based on

test data.21

Commentary Fig. R12.6(a) shows the length of headed deformed bar l

dt measured from the critical section to the

bearing face of the head, which is given in section 12.6.2 for developing headed deformed bars.

use of headed deformed bars is attractive as an alternative to hooked bar anchorages in regions where reinforcement is heavily congested.

The term development, as used in section 12.6, indicates that “the force in the bar is transferred to the concrete through a combination of a bearing force at the head and bond forces along the bar.” The term anchorage, as used in section 12.6, indicates that “the force in a bar is transferred to the concrete through bearing of the head alone.”

Commentary section R12.6 states that the “provisions for headed deformed bars were written with due consideration of the provisions for anchorage in Appendix D and the

Figure 2. Typical arrangements are shown for headed shear-stud reinforcement and critical sections. Reproduced with permission from ACI 318-08 Figure R11.11.5.Fig. R11.11.5—Typical arrangements of headed shear stud reinforcement and critical sections.

Page 16: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS8

from the face of the column that is equal to the thickness of the projection below the slab soffit.”

In section 13.3, what used to be called special reinforce-ment is now called corner reinforcement. Corner reinforce-ment is now required “at exterior corners of slabs support-ed by edge walls or where one or more edge beams have a value of α

f greater than 1.0.”

New, useful commentary is provided in section R13.3.6. In section 13.3.8.5, column core was replaced by region bounded by the longitudinal reinforcement of the column.

Section 13.5.3.3 on transfer of unbalanced moments to col-umns was editorially rewritten for clarity. Two substantive changes have also been made. The limit of 37.5% of the balanced steel ratio on the amount of reinforcement within the effective slab width was updated to refer to a minimum net tensile strain of 0.010 to be consistent with the unified design approach, and the requirement for the minimum net tensile strain was eliminated for moment transfer about the slab edge for edge and corner connections based on the original recommendation from ACI Committee 352.

New commentary section R13.6.7 explains the moment re-distribution of up to 10% that is permitted to occur in slabs that are analyzed using the direct design method.

Chapter 14: “Walls”

Section 14.3.7 used to read, “In addition to the minimum reinforcement required by 14.3.1, not less than two no. 5 bars shall be provided around all window and door openings. Such bars shall be extended to develop the bar beyond the corner of the openings but not less than 24 in.”

The section now reads, “In addition to the minimum rein-forcement required by 14.3.1, not less than two no. 5 bars in walls having two layers of reinforcement in both direc-tions and one no. 5 bar in walls having a single layer of reinforcement in both directions shall be provided around window, door, and similar sized openings. Such bars shall be anchored to develop f

y in tension at the corners of the

openings.”

Section 14.8, “Alternative Design of Slender Walls,” was introduced in the 1999 edition of ACI 318, and the provi-sions are based on similar provisions in the Uniform Build-ing Code (UBC),22 which in turn are based on experimen-tal research.23 Changes were made in the 2008 edition to reduce differences in the serviceability provisions between ACI 318 and the UBC to ensure that the intent of the UBC provisions is included in future editions of the IBC.

Before the 2008 edition, under section 14.8.3, the effec-tive area of longitudinal reinforcement in a slender wall for obtaining an approximate cracked moment of inertia was calculated using an effective area of tension reinforce-

“For bars in tension, heads allow the bars to be developed in a shorter length than required for standard hooks.19–21 The minimum limits on clear cover, clear spacing, and head size are based on the lower limits on these param-eters used in the tests to establish the expression for l

dt in

[section] 12.6.2. … Headed bars with Abrg

< 4Ab have been

used in practice, but their performance may not be accu-rately represented by the provisions of [section] 12.6.2.” Headed bars may be used only in compliance with the requirements of section 12.6.4.

“A factor of 1.2 is consistently used for epoxy-coated headed reinforcing bars, the same value as used for epoxy-coated standard hooks.” The upper limit of 6000 psi on the value of

fc' in section 12.6.2 is based on the concrete

strengths used in the Texas tests.19–21

“Because transverse reinforcement was shown to be largely ineffective in improving the anchorage of headed deformed bars, additional reductions in development length … are not used for headed deformed reinforcing bars.” The sole exception to this is a reduction for excess reinforcement.

Commentary section R12.6 indicates that where longitudi-nal headed deformed bars from a beam or slab terminate at a column or other supporting member, as shown in Figure R12.6(b), “the bars should extend through the joint to the far face of the supporting member, allowing for cover and avoiding interference with column reinforcement, even though the resulting anchorage length exceeds l

dt.” Ex-

tending the bar to the far face of the supporting member improves the performance of the joint.

Section 12.6.3 requires that heads “not be considered effec-tive in developing bars in compression” because there are no available test data demonstrating that “the use of heads adds significantly to anchorage strength in compression.”

In section 12.8, Eq. (12-3) for the development length of plain welded-wire reinforcement in tension now shows the lightweight-aggregate factor λ in a position that is consis-tent with its definition in section 8.6. In section 12.13, the expression for the embedment length of web reinforce-ment between the midheight of a member and outside end of the hook now contains λ. In section 12.15, “Splices of Deformed Bars and Deformed Wire in Tension,” section 12.15.3 was added. The section states that “when bars of different size are lap spliced in tension, splice length shall be the larger of l

d of larger bar and tension lap splice length

of smaller bar.”

Chapter 13: “Two-Way Slab Systems”

Section 13.2.6 has also been added. This section states that “when used to increase the critical concrete section for shear at a slab-column joint, a shear cap shall project below the slab and extend a minimum horizontal distance

Page 17: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S9PCI Journal | Specia l Supplement

Chapter 17: “Composite Concrete Flexural Members”

No change was made to this chapter.

Chapter 18: “Prestressed Concrete”

One important change in section 18.4.1 permits an increase in the allowable concrete compressive stress immediately after prestress transfer at the ends of pretensioned, simply supported members from 0.60

fci' to 0.70

fci' . This change

was made based on research results and common practice in the precast/prestressed concrete industry. The remainder of section 18.4.1 was editorially rewritten.

Section 18.8.2 on minimum flexural reinforcement was editorially rewritten.

A sentence added to commentary section R18.8.2 points out that the requirement of section 18.8.2 does not apply to members with unbonded tendons because the “transfer of force between the concrete and the prestressing steel, and abrupt flexural failure immediately after cracking, does not occur when prestressing steel is unbonded.”24

Changes were made in section 18.10.4 on redistribution of moments in continuous prestressed flexural members, which are very similar to the corresponding changes made in section 8.4 on redistribution of moments in continuous nonprestressed flexural members.

Section 18.12.4 provides “specific guidance concern-ing tendon distribution that will permit the use of banded tendon distributions in one direction. . . . The minimum average effective prestress of 125 psi was used in two-way test panels in the early 1970s to address punching shear concerns in lightly reinforced slabs.”

A sentence was added to clearly indicate that if the slab thickness varies along or perpendicular to the span of a slab “resulting in a varying slab cross section, the 125 psi minimum effective prestress and the maximum tendon spacing are required at every cross section tributary to the tendon or group of tendons along the span, considering both the thinner and the thicker slab sections.”

There are significant modifications of the requirements for structural integrity steel in two-way, unbonded, post-tensioned slab systems, previously in section 18.12.4, now in sections 18.12.6 and 18.12.7.

Section 18.12.6 requires that “in slabs with unbonded tendons, a minimum of two ½-in. diameter or larger, sev-en-wire post-tensioned strands shall be provided in each direction at columns, either passing through or anchored within the region bounded by the longitudinal reinforce-ment of the column.” Such reinforcement provided at

ment defined by Eq. (14-7) without the h/2d modifier. The contribution of the axial load to the cracked moment of inertia was overestimated in many cases where two layers of reinforcement were used in a slender wall. The effective area of longitudinal reinforcement was modified in 2008 by introducing the h/2d modifier. “The neutral axis depth c in Eq. (14-7) corresponds to this effective area of longitu-dinal reinforcement.”

Section 14.8.4 has undergone significant changes. Prior to this edition, out-of-plane deflections of wall panels were calculated using the effective moment of inertia given in section 9.5.2.3. “However, reevaluation of the original test data23 indicated that out-of-plane deflections increase rapidly when the service-level moment exceeds 2/3M

cr. A

linear interpolation between ∆cr [given by Eq. (14-10)] and

∆n [given by equation (14-11)] is used to determine ∆

s to

simplify the design of slender walls” if the maximum mo-ment in member due to service loads M

a exceeds 2/3M

cr.

Commentary section R14.8.4 states that “service-level load combinations are not defined in Chapter 9 of ACI 318.” However, they are discussed in appendix C of ASCE/SEI 7-05, although, unlike ACI 318, “appendixes to ASCE/SEI 7 are not considered to be mandatory parts of the stan-dard.” Appendix C of ASCE 7-05 recommends the follow-ing load combination for calculating service-level lateral deflections of structures:

D + 0.5L + 0.7W

“which corresponds to a 5% annual probability of ex-ceedance.”

According to section R14.8.4, “if a slender wall is designed to resist earthquake effects, E, and E is based on strength-level seismic forces,” a conservative estimate of service-level seismic forces is 0.7E.

Chapter 15: “Footings”

An important new section 15.10.4 was added, stating unequivocally that the minimum reinforcing steel in non-prestressed mat foundations shall meet the requirements of section 7.12.2 in each principal direction and that the maxi-mum spacing shall not exceed 18 in. The new commentary section R15.10.4 also supplies important clarification. It states that “minimum reinforcing steel may be distributed near the top or bottom of the section, or may be allocated between the two faces of the section as deemed appropriate for specific conditions, such that the total area of continu-ous reinforcing steel satisfies [section] 7.12.2.”

Chapter 16: “Precast Concrete”

No substantive changes were made to this chapter.

Page 18: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS10

The test load intensity in section 20.3.2 of ACI 318-05, 0.85 (1.4D + 1.7L), was not changed when the ASCE/SEI 7 load combinations were brought into the main body of ACI 318-02 because Committee 318 did not want to re-duce the fundamental level of structural safety. However, the ACI 318-05 format was confusing to practitioners be-cause it appeared to refer only to the traditional ACI load combinations, which are now in appendix C. Also, test load combinations including snow and rain loads were not provided. To correct these deficiencies without substan-tially changing the test load intensity, the required test load intensity was revised to be not less than the largest value given by three different load combinations.

References

1. ACI Committee 318. 2005. Building Code Require-ments for Structural Concrete (ACI 318-05) and Commentary (ACI 318R-05). Farmington Hills, MI: American Concrete Institute (ACI).

2. ACI Committee 318. 2008. Building Code Require-ments for Structural Concrete (ACI 318-08) and Com-mentary (ACI 318R-08). Farmington Hills, MI: ACI.

3. International Code Council. 2006. International Building Code. Falls Church, VA: International Code Council.

4. Structural Engineering Institute. 2005. Minimum Design Loads for Buildings and Other Structures. Reston, VA: American Society of Civil Engineers (ASCE).

5. Mlakar, P. F., ed. 2005. Special Section: Performance of the Pentagon: Terrorist Attack of September 11, 2001. Journal of Performance of Constructed Facili-ties, V. 15, No. 3 (August): pp. 187–221.

6. Nowak, A. S., N. M. Szerszen, E. K. Szeliger, A. Szwed, and P. K. Podhorecki. 2005. Reliability-Based Calibration for Structural Concrete. Report No. UN-LCE 05-036. Lincoln, NE: University of Nebraska.

7. Khuntia, M., and S. K. Ghosh. 2004. Flexural Stiff-ness of Reinforced Concrete Columns and Beams: Analytical Approach. ACI Structural Journal, V. 101, No. 3 (May–June): pp. 351–363.

8. Khuntia, M., and S. K. Ghosh. 2004. Flexural Stiff-ness of Reinforced Concrete Columns and Beams: Analytical Approach. ACI Structural Journal, V. 101, No. 3 (May–June): pp. 364–374.

9. Tikka, T. K., and S. A. Mirza. 2006. Nonlinear Equa-tion for Flexural Stiffness of Slender Composite Col-umns in Major Axis Bending. Journal of Structural Engineering, V. 132, No. 3 (March): pp. 387–399.

any location over the depth of the slab suspends the slab following a punching shear failure, provided the tendons “are prevented from bursting through the top surface of the slab.”25

“Where the two structural integrity tendons are anchored within the region bounded by the longitudinal reinforce-ment of the column,” the anchorage is required to be located beyond the column centroid and away from the anchored span. “Outside column and shear cap faces, these two structural integrity tendons are required to pass under any orthogonal tendons in adjacent spans” so that vertical movements of the integrity tendons are restrained by the orthogonal tendons.

“Where tendons are distributed in one direction and banded in the orthogonal direction, this requirement can be satis-fied by first placing the integrity tendons for the distributed tendon direction and then placing the banded tendons.” Commentary section R18.12.6 states that “where tendons are distributed in both directions, weaving of tendons is necessary and the use of [section] 18.12.7 may be an easier approach.” That section allows the structural integrity tendons to be replaced by deformed-bar bottom reinforce-ment.

In section 18.13.4 (section 18.13 is on “Post-tensioned Tendon Anchorage Zones”), nominal tensile stress was changed to tensile stress at nominal strength, nominal compressive strength of concrete to compressive stress in concrete at nominal strength, and design drawings to contract documents.

Chapter 19: “Shells and Folded Plate Members”

Section 19.4.2, instead of providing values of the coeffi-cient of friction µ, now refers to section 11.6.4.3 for those values.

A few other changes, which are essentially editorial, were made in the chapter.

Chapter 20: “Strength Evaluation of Existing Structures”

Since the 1995 edition of ACI 318, section 20.2.3 refer-enced section 5.6.5 for determining concrete strength from cores when evaluating the strength of an existing structure. However, section 5.6.5 was developed for investigating low-strength test results, not evaluating the strength of existing structures. ACI Committee 214 has developed procedures for estimating an equivalent

fc' from core test

data. The requirements of section 20.2.3 were changed to require an estimate of an equivalent

fc' and the commentary

references the ACI 214.4R-03 methods.26

Page 19: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S11PCI Journal | Specia l Supplement

22. International Conference of Building Officials (ICBO). 1997. Uniform Building Code. Whittier, CA: ICBO.

23. Athey, J. W, ed. 1982. Test Report on Slender Walls. Los Angeles, CA: Southern California Chapter of the American Concrete Institute and Structural Engineers Association of Southern California.

24. Joint ACI-ASCE Committee 423. 2005. Recom-mendations for Concrete Members Prestressed with Unbonded Tendons (ACI 423.3R-05). Farmington Hills, MI: ACI

25. Joint ACI-ASCE Committee 352. 1988. Recom-mendations for Design of Slab-Column Connections in Monolithic Reinforced Concrete Structures (ACI 352.1R-89). ACI Structural Journal, V. 85, No. 6 (November–December): pp. 675–696.

26. ACI Committee 214. 2003. Guide for Obtaining Cores and Interpreting Compressive Strength Results (ACI 214.4R-03). Farmington Hills, MI: ACI.

Notation

Ab = area of an individual bar or wire

Abrg

= net bearing area of the head of stud, anchor bolt, or headed deformed bar

Ag = gross area of concrete section

Av = area of shear-reinforcement within spacing s

bo = perimeter of critical section for shear in slabs and

footings

bw = web width or diameter of circular section

c = distance from extreme compression fiber to neutral axis

d = distance from extreme compression fiber to centroid of longitudinal tension reinforcement

D = dead loads or related internal moments and forces

E = load effects of earthquake or related internal moments and forces

EI = flexural stiffness of compression member

fy = specified yield strength of nonprestressed

reinforcement

fyt = specified yield strength of transverse reinforcement

10. Ghosh, S. K. 2008. “Significant Changes to ACI 318-08 Relative to Precast/Prestressed Concrete: Part 1.” PCI Journal, V. 53, No. 2 (March–April): supplement.

11. Hawkins, N. M., and S. K. Ghosh. 2006. Shear Strength of Hollow-Core Slabs. PCI Journal, V. 51, No. 1 (January–February): pp. 110–114.

12. Angelakos, D., E. C. Bentz, and M. D. Collins. 2001. Effect of Concrete Strength and Minimum Stirrups on Shear Strength of Large Members. ACI Structural Journal, V. 98, No. 3 (May–June): pp. 290–300.

13. Lubell, A., E. C. Sherwood, E. C. Bentz, and M. P. Collins. 2004. Safe Shear Design of Large Wide Beams. Concrete International, V. 26, No. 1 (Janu-ary): pp. 66–78.

14. Brown, M. D., O. Bayrak, and J. O. Jirsa. 2006. Design for Shear Based on Loading Conditions. ACI Structural Journal, V. 103, No. 4 (July–August): pp. 541–550.

15. Parra-Montesinos, G. J. 2006. Shear Strength of Beams with Deformed Steel Fibers. Concrete Interna-tional, V. 28, No. 11 (November): pp. 57–66.

16. Kahn, L. F., and A. D. Mitchell. 2002. Shear Fric-tion Tests with High-Strength Concrete. ACI Struc-tural Journal, V. 99, No. 1 (January–February): pp. 98–103.

17. Mattock, A. H. 2001. Shear Friction and High-Strength Concrete. ACI Structural Journal, V. 98, No. 1 (January–February): pp. 50–59.

18. ACI-ASCE Committee 421. 1999 (reapproved 2006). Shear Reinforcement for Slabs. ACI 421.1R-99. Farmington Hills, MI: ACI.

19. Thompson, M. K., M. J. Ziehl, J. O. Jirsa, and J. E. Breen. 2005. CCT Nodes Anchored by Headed Bars—Part 1: Behavior of Nodes. ACI Structural Journal, V. 102, No. 6 (November–December): pp. 808–815.

20. Thompson, M. K., J. O. Jirsa, and J. E. Breen. 2006. CCT Nodes Anchored by Headed Bars—Part 2: Ca-pacity of Nodes. ACI Structural Journal, V. 103, No. 1 (January–February): pp. 65–73.

21. Thompson, M. K., A. Ledesma, J. O. Jirsa, and J. E. Breen. 2006. Lab Splices Anchored by Headed Bars. ACI Structural Journal, V. 103, No. 2 (March–April): pp. 271–279.

Page 20: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS12

αf = ratio of flexural stiffness of beam section to flexural

stiffness of a width of slab bounded laterally by centerlines of adjacent panes (if any) on each side of the beam

γv = factor used to determine the unbalanced moment

transferred by eccentricity of shear at slab-column connections

∆cr = computed out-of-plane deflection at midheight of

wall corresponding to cracking moment

∆n = computed out-of-plane deflection at midheight of

wall corresponding to nominal flexural strength

∆s = computed out-of-plane deflection at midheight of

wall due to service loads

λ = modification factor reflecting the reduced mechani-cal properties of lightweight concrete

µ = coefficient of friction

φ = strength-reduction factor

vn = nominal shear-stress capacity

= 3λ

fc

' + Av fyt

/(bos)

fc' = specified compressive strength of concrete

fci' = specified compressive strength of concrete at time of

initial prestress

h = overall thickness or height of member

I = moment of inertia of section about centroidal axis

k = effective length factor for compression members

Ktr = transverse reinforcement index

ld = development length in tension of deformed bar,

deformed wire, plain and deformed welded-wire reinforcement, or pretensioned strand

ldt = development length in tension of headed deformed

bar, measured from the critical section to the bearing face of the head

lu = unsupported length of compression member

L = live loads or related internal moments and forces

M1 = smaller factored end moment on a compression

member

M2 = larger factored end moment on a compression

member

Ma = maximum moment in member due to service loads

Mcr = cracking moment

Mu

= factored moment at section

r = radius of gyration of cross section of a compression member

s = center-to-center spacing of items, for example, spacing of the peripheral lines of headed shear-stud reinforcement

Vc = nominal shear strength provided by concrete

Vd = shear force at section due to unfactored dead load

Vn = nominal shear strength

Vs = nominal shear strength provided by shear

reinforcement

Vu = factored shear force at section

Page 21: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S13PCI Journal | Specia l Supplement

About the author

S. K. Ghosh, PhD, FPCI, is president of S. K. Ghosh Associ-ates Inc. in Palatine, Ill.

Synopsis

Significant changes were made since American Concrete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Structural Con-crete (ACI 318-05) and Commentary (ACI 318R-05). The changes in the upcoming 2008 edition are sum-marized here. In addition to changes affecting con-ventionally reinforced concrete, provisions affecting precast/prestressed concrete, including post-tensioned

concrete, are enumerated. Only changes to chapters 9 through 20 of ACI 318-08 are discussed in this article.

Keywords

ACI 318, code, structural concrete.

Reader comments

Please address any reader comments to PCI Journal editor-in-chief Emily Lorenz at [email protected] or Precast/Prestressed Concrete Institute, c/o PCI Journal, 209 W. Jackson Blvd., Suite 500, Chicago, IL 60606. J

Page 22: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

A SPECIAL MEMBERS-ONLY SUPPLEMENTNo. 53-5

Letter to the Editor: Exposure Class Assignments ......................S2

Significant Changes to ACI 318-08

Relative to Precast/Prestressed Concrete:

Part 3 ..................................................................................S2

S. K. Ghosh

209 West Jackson Boulevard I Suite 500 I Chicago, IL 60606Phone: 312-786-0300 I Fax: 312-786-0353 I www.pci.org

209 West Jackson BoulevardSuite 500 Chicago, IL 60606

Phone: 312-786-0300Fax: 312-786-0353

www.pci.org

209 West Jackson Boulevard I Suite 500 I Chicago, IL 60606Phone: 312-786-0300 I Fax: 312-786-0353 I www.pci.org

209 West Jackson BoulevardSuite 500 Chicago, IL 60606

Phone: 312-786-0300Fax: 312-786-0353

www.pci.org

209 West Jackson Boulevard I Suite 500 I Chicago, IL 60606Phone: 312-786-0300 I Fax: 312-786-0353 I www.pci.org

209 West Jackson BoulevardSuite 500 Chicago, IL 60606

Phone: 312-786-0300Fax: 312-786-0353

www.pci.org

Page 23: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalSpecia l Supplement | PCI JournalS2

Significant changes have been made since American Concrete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Structural Con-crete (ACI 318-05) and Commentary (ACI 318R-05).1 The changes in the new 2008 edition2 are summarized in this series of papers.

The intent of this series of articles is to provide a sum-mary of significant changes that affect conventionally reinforced concrete, precast concrete, and prestressed concrete (including post-tensioned concrete). This in-formation should be useful to building officials, design engineers, practitioners, and the academic community. Changes to chapters 1 through 8 of ACI 318-08 were discussed in part 1 of this article series, published as a member supplement to the March–April 2008 issue of the PCI Journal. Changes to chapters 9 through 20 were discussed in part 2 of this article series, published in a supplement to the May–June 2008 issue of the PCI Journal. Changes to chapter 21 are discussed in this part 3 of the article series. Changes to the appendices will be discussed in a separate article, which will appear in a subsequent issue of the PCI Journal.

Editor’s quick points

n  This part 3 of three papers describes the changes from the 2005 edition to the 2008 edition of ACI 318, Building Code Requirements for Structural Concrete and Commentary, for chapter 21.

n  ACI 318 underwent a major revision with this version.

n  Changes to the appendices will follow in a separate article in a subse-quent issue of the PCI Journal.

Letter to the Editor

Exposure class assignmentsIn “Significant Changes to ACI 318-08 Relative to Precast/Prestressed Concrete: Part 1” in the supplement to the

March–April 2008 issue of the PCI Journal, S. K. Ghosh provided a nice summary of significant changes to chapters 1 through 8 of Building Code Requirements for Structural Concrete (ACI 318-05) and Commentary (ACI 318R-05).

I would like to add a comment. In my view, one of the more significant changes in chapter 4 of ACI 318-08 is the statement in section 4.2.1 that “The licensed design professional shall assign exposure classes based on the severity of the anticipated exposure of structural concrete members for each exposure category according to Table 4.2.1.”

This statement explicitly requires the licensed design professional to consider and assign exposure classes for the struc-ture in accordance with the new format for durability provisions. This change may be of interest to your members.

Anthony E. FioratoSenior consultantCTLGroupSkokie, Ill.

Significant changes to ACI 318-08 relative to precast/prestressed

concrete: Part 3S. K. Ghosh

Page 24: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

PCI Journal | Specia l Supplement S3

But then the model building codes started triggering seismic detailing requirements by seismic performance categories, which were a function of the seismic hazard at the site and the occupancy of the structure. The IBC3 now triggers seismic detailing requirements by seismic design categories (SDCs) that are additionally functions of the soil characteristics at the site. Thus, in recent times, ACI 318 has used the awkward language: “in regions of low seismic risk or for structures as-signed to low seismic performance or design categories,” “in regions of moderate seismic risk or for structures assigned to intermediate seismic performance or design categories,” and “in regions of high seismic risk or for structures assigned to high seismic performance or design categories.”

ACI 318-08 has dropped this cumbersome language. Instead, SDCs are now used directly in section 1.1.9, “Provisions for Earthquake Resistance,” section 21.1.1, “Scope,” and else-where. This is a significant positive development. Because the IBC will no longer have to provide an interface between the SDC and the regions of low, moderate, and high seismic risk of ACI 318, it will be possible to eliminate unnecessary amendments to ACI 318 requirements.

More logical organization

In ACI 318-05, design and detailing requirements for struc-tures assigned to SDC A and B were located in chapters 1 through 18. Additional detailing requirements for structures assigned to SDC C were given in sections 21.12 and 21.13, and those for structures assigned to SDCs D, E, and F were given in sections 21.2.2 through 21.2.8 and 21.3 through 21.10. This was obviously not the most logical arrangement.

In ACI 318-08, seismic detailing requirements have been or-ganized in the order of ascending SDCs. Chapter 21 starts with two new provisions for SDC B structures and the provisions for SDC C structures (commonly referred to as intermediate detail-ing) follow. Appearing last in chapter 21 are the provisions for SDC D, E, and F structures (commonly referred to as special detailing). Table 1 shows the section number changes that have resulted in chapter 21 from ACI 318-05 to 318-08.

Deliberate use of special

A primary use of the term special in chapter 21 is to define structural systems in which the proportions and details make them suitable as primary lateral-force-resisting systems of structures assigned to high SDCs. However, the term special was also used throughout chapter 21 for other purposes, some-times leading to confusion in code usage. Any unnecessary or confusing use of the term special has now been removed from all of chapter 21, as well as from a few locations in chapter 1 that refer to seismic design requirements.

Retention of the term special transverse reinforcement, which refers to the confinement reinforcement within the region of

ACI 318-08 will be the reference document for concrete design and construction in the 2009 edi-tion of the International Building Code (IBC),3 which will continue to reference ASCE 7-05.4

All section and chapter numbers used in this paper refer to those of ACI 318-08 unless otherwise noted.

Overall changes to chapter 21: “Earthquake-Resistant Structures”

A number of overall changes have been made to chapter 21.

Title

The title of the chapter has changed from “Special Provisions for Seismic Design” to “Earthquake-Resistant Structures.”

Notation

In previous editions of ACI 318, the format was to have all definitions in chapter 2, with the excep-tion of chapter 21, which in ACI 318-05 contained definitions. Having definitions in two places is undesirable because there can be problems in updating the definitions consistently. Alternatively, having definitions in chapter 21 but not chapter 2 can create difficulties locating definitions. Thus, all definitions have been transferred from chapter 21 to chapter 2. In addition to the transfer, a few of the definitions have been modified.

Detailing requirements by seismic design category

ACI Committee 318 originally developed seismic design provisions for regions of high seismic risk. The design provisions were placed in appendix A in earlier versions of ACI 318 and subsequently in chapter 21. Provisions for regions of moderate seismic risk were added later.

It has always been understood among the users of ACI 318 that the body of the document, excluding chapter 21, provides design and detailing require-ments for regions of low seismic risk. As long as the model building codes divided the United States into Seismic Zones 0 through 4, and seismic detail-ing requirements were triggered by seismic zones, it was relatively easy for the practicing engineer to correlate the regions of low, moderate, and high seismic risk of ACI 318 with the Seismic Zones 0 through 4 of the model codes.

Page 25: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS4

specifically prohibits such use in members resisting earthquake-induced forces in structures assigned to SDC D, E, or F. This was largely a result of some misgiving that high-strength spiral reinforcement might be less ductile than conventional mild rein-forcement and that spiral failure has been observed in earthquakes.

There are fairly convincing arguments, however, against such specific prohibition. Spiral failure, primarily observed in bridge columns, has invariably been the result of insufficient spiral reinforcement. Also, prestressing steel, which is primarily the high-strength steel available on the U.S. market, is at least as ductile as welded-wire reinforcement, which is allowed to be used as transverse reinforcement.

Under 2006 IBC section 1908.1.5, the applicability of the ACI 318-05 restriction “The value of f

yt for

transverse reinforcement including spiral reinforce-ment shall not exceed 60,000 psi” is narrowed by the clause “for computing shear strength” in front of the requirement.

Two of the functions of transverse reinforcement in a reinforcement concrete member are to confine the concrete and to act as shear reinforcement. There has been enough testing of columns6–8 with high-strength confinement reinforcement ( f

yt ranging

up to 120 ksi [830 MPa] and beyond) to show that

potential plastic hinging at the ends of special-moment-frame columns, was considered. However, following an ACI 318 ballot, this was dropped from further consideration.

Specific changes to chapter 21

More-specific changes to chapter 21 are large in number.

Removal of commentary sentence

When the committee was removing the word special, it was noted that the 2003 National Earthquake Hazards Reduction Program (NEHRP) provisions5 and ASCE 7-054 now include intermediate precast concrete walls. So the no-longer-relevant commentary sentence, “Although new provisions are provided in 21.13 for design of intermediate precast structural walls, gen-eral building codes that address seismic performance or design categories do not include intermediate structural walls,” was struck from ACI 318-08 commentary section R21.1.1 (previ-ously ACI 318-05 commentary section R21.2.1).

High-strength transverse reinforcement

Section 21.2.5 of ACI 318-05 introduced a sentence that limits the yield strength of transverse reinforcement, includ-ing spirals, to 60,000 psi (42 MPa). The added sentence was part of a change that modified ACI 318-02 sections 9.4 and 10.9.3 to allow the use of spiral reinforcement with specified yield strength up to 100 ksi (690 MPa). The added sentence

Table 1. ACI 318-05 and the corresponding ACI 318-08 chapter 21 section numbers

ACI 318-08 section numbers ACI 318-05 section numbers

All definitions have moved to chapter 2 21.1 Definitions

21.1 General Requirements 21.2 Same title

21.2 Ordinary Moment Frames Not included

21.3 Intermediate Moment Frames 21.12 Requirements for Intermediate Moment Frames

21.4 Intermediate Precast Structural Walls 21.13 Same title

21.5 Flexural Members of Special Moment Frames 21.3 Same title

21.6 Special Moment-Frame Members Subjected to Bending and Axial Load

21.4 Same title

21.7 Joints of Special Moment Frames 21.5 Same title

21.8 Special Moment Frames Constructed Using Precast Concrete 21.6 Same title

21.9 Special Structural Walls and Coupling Beams 21.7 Special Reinforced Concrete Structural Walls and Coupling Beams

21.10 Special Structural Walls Constructed Using Precast Concrete 21.8 Same title

21.11 Structural Diaphragms and Trusses 21.9 Same title

21.12 Foundations 21.10 Same title

21.13 Members Not Designated as Part of the Seismic-Force-Resisting System

21.11 Members Not Designed as Part of the Lateral-Force-Resisting System

Page 26: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

“In structures assigned to SDC B, flexural member of or-•dinary moment frames forming part of the seismic force-resisting system shall have at least two main flexural reinforcing bars continuously top and bottom throughout the beams through or developed within exterior columns or boundary elements.”

“In structures assigned to SDC B, columns of ordinary •moment frames having a clear height-to-maximum-plan-dimension ratio of five or less shall be designed for shear in accordance with ACI 318-05 section 21.12.3 (ACI 318-08 section 21.3.3).”

Intermediate moment frames

There are important changes in section 21.3, “Intermediate Moment Frames.” Intermediate moment frames include beam-column as well as slab-column moment frames. When the re-quirements for intermediate moment frames were introduced in ACI 318-83, shear design requirements for beam-column and slab-column frames were grouped (section 21.12.3 of ACI 318-05). However, it was never intended that nominal shear stresses due to shear and moment transfer in two-way slab-column frames be treated the same as beam shear in beam-column frames or one-way shear in two-way slabs, though the provisions appear to indicate such. The provisions of former section 21.12.3 constrained slab-column designs in a way that was not intended and that was not supported by observations in laboratory tests.

Analyses of laboratory tests14 indicate that the ductility or in-elastic deformability of slab-column framing is better judged on the basis of the level of gravity shear stress and the presence of slab shear reinforcement. This has been recognized for gravity framing of buildings assigned to high SDCs (section 21.13.6) and slab-column intermediate frames (section 21.3.6.8).

The purpose of a significant change to section 21.3.6.8 was to clarify that the nominal shear stresses due to shear and moment transfer in two-way slabs do not need to satisfy the requirements of section 21.3.3, but instead only need to satisfy the requirements of section 21.3.6.8. In addition, sec-tion 21.3.6.8 was modified to make it more consistent with current understanding of the relationship between earthquake demands and strengths, as reflected in section 21.13.6. ACI 318-05 permitted the value of eccentric shear stress to reach v

n for design load combinations including E, as long as the

contribution of E does not exceed 0.5vn. Considering that E

was the linear earthquake action divided by a force-reduction factor R, ACI 318-05 was believed to permit unsafe levels of nominal shear stresses.

A modification has eliminated this provision in ACI 318-08 and has replaced it with a more rational one. Specifically, in section 21.3.6.8 (formerly section 21.12.6.8), the second sentence has been changed from “It shall be permitted to waive this require-ment if the contribution of the earthquake-induced factored

there is no detriment to such use. The 2006 IBC, therefore, uses the ACI 318-05 upper limit on the yield strength of transverse reinforcement solely to limit the width of possible shear cracks to accept-able levels. This does not preclude the use of high-strength transverse reinforcement for confining the core of a concrete member.

During discussion of this item within ACI 318 Subcommittee H, Budek9 introduced research results that showed equivalent shear and confine-ment performance of 18-in.-diameter columns with transverse reinforcement having roughly 200 ksi (1380 MPa) yield strength.

Section 21.1.5.4 of ACI 318-08 now states, “The value of f

yt used to compute the amount of confine-

ment reinforcement shall not exceed 100,000 psi.”

Section 21.5.5.5 of ACI 318-08 now states, “The value of f

y or f

yt used in design of shear reinforce-

ment shall conform to 11.4.2.”

Section 11.4.2 reads, “The values of fy and f

yt used

in design of shear reinforcement shall not exceed 60,000 psi, except the value shall not exceed 80,000 psi for welded deformed wire reinforcement.”

Thus, unlike the 2006 IBC, ACI 318-08 imposes an upper limit of 100 ksi (690 MPa) on the yield strength of high-strength confinement reinforce-ment in members resisting earthquake-induced forc-es in structures assigned to SDC D, E, or F. Also, ACI 318-08 requires such transverse reinforcement to conform to ASTM A1035.10 Section 3.5.3.1 requires deformed reinforcing bars to conform to ASTM A61511 (carbon steel), ASTM A70612 (low-alloy steel), and ASTM A95513 (stainless steel).

Ordinary moment frames

Section 21.2, for the first time, contains specific detailing requirements for ordinary moment frames in buildings assigned to SDC B.

Both SDC A and SDC B fall under the old desig-nation of low seismic risk. Structures assigned to SDC A are required to satisfy chapters 1 through 18 and chapter 22 of ACI 318. Frames in buildings assigned to SDC A are required in both the 2003 NEHRP provisions5 and ASCE 7-054 to satisfy ad-ditional requirements. The additional requirements of ASCE 7-05 are:

S5PCI Journal | Specia l Supplement

Page 27: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS6

two-way shear stress transferred by eccentricity of shear in ac-cordance with 11.12.6.1 and 11.12.6.2 at the point of maximum stress does not exceed one-half of the stress v

n permitted by

11.12.6.2” to “It shall be permitted to waive this requirement if the slab design satisfies requirements of 21.13.6.”

Columns supporting discontinued shear walls

Discontinuous shear walls and other stiff members can impose large axial forces on supporting columns during earthquakes. Section 21.4.4.5 of ACI 318-05 already contained transverse reinforcement requirements for such columns in order to improve column toughness under anticipated demands. The requirements are triggered when “the factored axial compres-sive force in these members, related to earthquake effect, exceeds Ag fc

' /10.” The same requirements continue in sec-tion 21.6.4.6 of ACI 318-08. However, the trigger has been adjusted by adding the following sentence: “Where design forces have been magnified to account for the overstrength of the vertical elements of the seismic-force-resisting system, the limit of A

g fc' /10 shall be changed to A

g fc' /4.”

While section 21.6.4.6 applies to columns of special moment frames, ACI 318-08 has added corresponding requirements for columns of intermediate moment frames. Section 21.3.5.6 requires the following:

Columns supporting reactions from discontinuous stiff members, such as walls, shall be provided with transverse reinforcement at the spacing, s

0, as defined in 21.3.5.2 over

the full height beneath the level at which the discontinuity occurs if the portion of factored axial compressive force in these members related to earthquake effects exceeds A

g fc'

/10. Where design forces have been magnified to account for the overstrength of the vertical elements of the seismic-force-resisting system, the limit A

g fc' /10 shall be increased

to Ag fc

' /4. This transverse reinforcement shall extend above and below the columns as required in 21.6.4.6(b).

It should be noted that the confinement that section 21.3.5.6 requires is considerably less than that required by section 21.6.4.6. Also, the 2006 IBC section 1908.1.12 modifies ACI 318-05 section 21.12.5 to introduce a provision similar to that of ACI 318-08 section 21.3.5.6.

Beams and joints of special moment frames

Changes have been made to sections 21.5, “Flexural Members of Special Moment Frames,” and 21.7, “Joints of Special Mo-ment Frames,” to clarify maximum beam width, joint confine-ment requirements, and design rules for joints having beam stubs extending a short distance past the joint.

Recent research15 has shown that the effective beam width is more closely related to the depth of the column than it is to

the depth of the beam. A recommendation based on the column widths and beam widths tested to date has been adopted.

Research16 has also indicated that extensions of beams (beam stubs) that project a short distance past the joint can also be considered as confining members to joints if they extend at least one effective depth beyond the joint face and meet the dimensional and reinforcment requirements for full flexural members. A change has been made to recognize this effect.

Section 21.5.1.4 now reads, “Width of member, bw,

shall not exceed width of supporting member, c2,

plus a distance on each side of supporting member equal to the smaller of (a) and (b):

(a) width of supporting member, c2, and

(b) 0.75 times the overall dimension of sup-porting member, c

1.”

It used to read, “plus distances on each side of sup-porting member not exceeding three fourths of the depth of flexural member.”

Sections 21.7.3.1, 21.7.3.2, and 21.7.3.3 on trans-verse reinforcement within beam-column joints of special moment frames have been rewritten for added clarity. Section 21.7.3.3, in particular, repre-sents a major improvement.

It used to read, “Transverse reinforcement as required by 21.4.4 [now 21.6.4] shall be provided through the joint to provide confinement for longitudinal beam reinforcement outside the column core if such confine-ment is not provided by a beam framing into the joint.”

It now reads, “Longitudinal beam reinforcement out-side the column core shall be confined by transverse reinforcement passing through the column that satis-fies spacing requirements of 21.5.3.2, and require-ments of 21.5.3.3 and 21.5.3.6, if such confinement is not provided by a beam framing into the joint.”

An example of transverse reinforcement through the column provided to confine the beam reinforce-ment passing outside the column core is now shown in Fig. R21.5.1. This figure is a welcome addition (Fig. 1).

Finally, the following text has been added to sec-tion 21.7.4.1: “Extensions of beams at least one overall beam thickness h beyond the joint face are permitted to be considered as confining mem-bers. Extensions of beams shall satisfy 21.5.1.3, 21.5.2.1, 21.5.3.2, 21.5.3.3, and 21.5.3.6.”

Page 28: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S7PCI Journal | Specia l Supplement

Columns of special moment frames

Significant changes have been made to section 21.6.4 to improve the organization and expres-sion of transverse reinforcement requirements for columns in special moment frames, as well as to eliminate one provision.

The provisions of section 21.6 are intended to apply to a column of a special moment frame for all load combinations if, for any load combination, the axial load exceeds Ag fc

' /10. The wording in ACI 318-05 was often misinterpreted as meaning that the provisions applied only for those load combinations for which the axial load exceeded A

g fc' /10. Thus,

section 21.6.1 of ACI 318-08 has been modified to read, “Requirements of this section apply to special moment frame members…that resist a factored axial compressive force P

u under any load combination

exceeding Ag fc

' /10.” (emphasis added)

Several areas for potential improvement of ACI 318-05 provisions related to columns of special moment-resisting frames were first identified by ACI 318 Subcommittee H. These included the following:

The items listed as (a) through (e) in ACI 318-•05 section 21.4.4.1 were not expressed in paral-lel language. ACI 318-05 required that the area of transverse reinforcement be determined using (a) or (b) but did not require that (c), (d), and (e) always be satisfied.

The term • design strength of the member core was used in ACI 318-05 in section 21.4.4.1(d), but that terminology was not well defined.

ACI 318-05 section 21.4.4 used both • bc and A

sh

to determine the required amount of special transverse requirement. However, b

c was

based on center-to-center dimensions and Ash

was based on the out-to-out dimensions of the hoop. To make it easier for the user, these items have been made consistent. In section 2.1 of ACI 318-08, both A

sh and b

c are “mea-

sured to the outside edges of transverse rein-forcement.” This amounts to a small increase in A

sh on the order of 2% to 3%.

Additional deliberations within ACI 318 Subcom-mittee H led to additional changes, including:

removing the terminology “special transverse •reinforcement” to refer to the confinement re-inforcement within the length l

o of the column;

eliminating ACI 318-05 section 21.4.4.1(d), which al-•lowed the design of columns with less than the specified confinement reinforcement, if the column core satisfied design requirements;

allowing crossties of diameter less than that of the hoops •(section 21.6.4.2).

ACI 318-05 section 21.4.4 has been replaced with the new ACI 318-08 section 21.6.4. The revision is outlined in Table 2. Note that the revised section 21.6.4 is made up of parts of ACI 318-05 section 21.4.4, with some revision and some reorganization.

Figure 1. Maximum effective width of wide beam and required transverse reinforcement. Source: Reprinted by permission from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) (Farmington Hills, MI: ACI, 2008) p. 334, Figure R21.5.1.

Page 29: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS8

concrete beams post-tensioned to precast or cast-in-place concrete columns. The columns are continuous through the joints, and each beam spans a single bay.

The hybrid beam-to-column connection uses a system of post-tensioning strands that run through a duct at the center of the beam and through the column. Mild-steel reinforcement is placed in ducts in the center of the beam and through the column, and then grouted. A key feature of the hybrid frame connection is that the grouted mild reinforcing bars must be deliberately debonded for short distances in the beams adjacent to the beam-column inter-faces in order to reduce the high cyclic strains that would otherwise occur at those locations. The amount of mild-steel reinforcement and post-tensioning steel are proportioned so that the frame recenters itself after a major seismic event.

The University of Washington test results for the Third and Mission building in San Francisco, Calif., and the Precast Seismic Structural Systems (PRESSS) building test results for the frame direction can be used as a basis for special precast concrete hybrid mo-ment frame designs in accordance with ITG-1.2. The results of the University of Washington tests are on file at ACI in conjunction with ITG-1.2. The results of the PRESSS building frame direction tests are avail-able in a series of reports from PCI.

The following sentence has been added at the end of section R21.8.4. “ACI ITG 1.2 defines design requirements for one type of special precast concrete moment frame for use in accordance with 21.8.4.”

ACI ITG-1.2 has also been added to the chapter 21 commentary reference list.

Boundary elements of special shear walls

Section 21.9.6.4 (c) has been changed to permit increased spacing of transverse reinforcement in the boundary elements of walls with relatively thin boundary zones.

ACI 318-05 section 21.7.6.4(c) required special boundary elements to satisfy ACI 318-05 section 21.4.4.2, which limited the spacing of transverse reinforcement to no more than one quarter of the minimum member dimension. This was an unin-tended consequence of referring the wall transverse reinforcement requirements to those of columns of special moment frames. For a 12-in.-thick (300 mm) wall, the spacing requirements could not exceed 3 in. (75 mm). The Uniform Building Code,19 in its last two editions, relaxed the maximum spacing to

A two-sentence paragraph has been added to section R21.6.4.4.

“Equations (21-4) and (21-5) are to be satisfied in both cross-sectional directions of the rectangular core. For each direc-tion, b

c is the core dimension perpendicular to the tie legs that

constitute Ash

, as shown in Fig. R21.6.4.2 [Fig. 2].”

This figure replaces ACI 318-05 Fig. R21.4.4 and represents a significant improvement.

Finally, the following sentence has been deleted from the commentary on ACI 318-05 section 21.4.4.6 (now 21.6.4.5). “Field observations have shown significant damage to columns in the unconfined region near the midheight. The requirements of 21.4.4.6 are to ensure a relatively uniform toughness of the column along its length.”

Special moment frames made with precast concrete

A change has been made to commentary section R21.8.4 to alert designers to ACI ITG-1.2,17 which provides an option to satisfy the provisions of section 21.1.1.8.

ACI 374.118 provides for the development of precast concrete special moment frames that can meet the requirements of sec-tion 21.1.1.8. ACI ITG-1.2 is an industry standard that defines requirements, in addition to those of section 21.8.4, for the design of one specific type of moment frame that consists of precast

Table 2. Reorganization of ACI 318-5 section 21.4.4 into ACI 318-08 section 21.6.4

ACI 318-08 section numbers ACI 318-05 section numbers

21.6.4.4 21.4.4.1

No change 21.4.4.1(a)

No change 21.4.4.1(b)

21.6.4.2 21.4.4.1(c)

Deleted 21.4.4.1(d)

21.6.4.7 21.4.4.1(e)

21.6.4.3 21.4.4.2

21.6.4.2 21.4.4.3

21.6.4.2 21.4.4.4

21.6.4.6 21.4.4.5

21.6.4.5 21.4.4.6

Eq. (21-3) Eq. (21-2)

Eq. (21-4) Eq. (21-3)

Eq. (21-5) Eq. (21-4)

Eq. (21-2) Eq. (21-5)

Page 30: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S9PCI Journal | Specia l Supplement

the smaller of 6 in. (150 mm) and 6 times the longi-tudinal bar diameter, regardless of wall thickness.

Wall specimens tested by Thomsen and Wallace20 included rectangular walls RW1 and RW2 with boundary transverse reinforcement spaced at three quarters of the wall thickness. The walls had lateral drift capacities in excess of 2% of the wall height.

Section 21.9.6.4(c) now reads, “The boundary element transverse reinforcement shall satisfy the requirements of 21.6.4.2 through 21.6.4.4 except Eq. (21-4) need not be satisfied and the transverse rein-forcement spacing limit of 21.6.4.3(a) shall be one-third of the least dimension of the boundary element.”

A sentence has been added at the end of section R21.9.6.4 that reads, “Tests show that adequate performance can be achieved using spacing larger than permitted by 21.6.4.3(a).”

The Thomsen and Wallace paper20 has also been added to the chapter 21 commentary reference list.

Coupling beams

In section 21.9.7, a clarification has been provided that the provisions of sections 21.5.2 through 21.5.4 can be applied to coupling beams of moderate aspect ratios (2 ≤ l

n/h < 4).

Conventional reinforcing details for coupling beams with moderate aspect ratios (2 ≤ l

n/h < 4) have at

times been disallowed by building departments, even though the intent of ACI 318 has always been to allow these details. The ACI 318-05 provisions for coupling beams that are part of the lateral-force-resisting system are summarized in Table 3.

It should be evident from Table 3 that ACI 318 was inadvertently silent on the issue of whether conven-tional reinforcement could be used in beams with 2 ≤ l

n/h < 4. ACI 318-05 section 21.7.7.2 used to read,

“Coupling beams with (ln/h) < 4 shall be permitted to

be reinforced with two intersecting groups of diago-nally placed bars symmetrical about the midspan.”

ACI 318-08 section 21.9.7.3 now reads, “Coupling beams not governed by 21.9.7.1 or 21.9.7.2 shall be permitted to be reinforced either with two intersecting groups of diagonally placed bars symmetrical about the midspan or according to 21.5.2 through 21.5.4.”

Significant changes have been made to sec-tion 21.9.7 to relax the spacing requirements for transverse reinforcement confining diagonal reinforcement in coupling beams and to introduce

an alternate detail involving confinement of the entire beam cross section (Fig. 3).

ACI 318-99 first introduced diagonal reinforcement in coupling beams. Among its provisions was the requirement that spacing not exceed one quarter of the minimum member dimension. For diagonally reinforced coupling beams, this dimension is defined as the cross section of the diagonal cage (out to out) plus nomi-nal cover. This may result in a spacing as low as 2 in. (50 mm) in practical situations. This appears to be unnecessarily restrictive.

Andres Lapage carried out a brief review of available diagonal-ly reinforced coupling beam test results for the benefit of sub-committee H. Paulay and Binney21 had tested a 6 in. × 31 in. (150 mm × 790 mm) coupling beam with a span-to-depth ratio of 1.3 and a 6 in. × 39 in. (150 mm × 990 mm) beam with a span-to-depth ratio of 1.0. The spacing of transverse reinforce-ment around the diagonal reinforcement in both beams was 4 in. (100 mm), 4.6d

b, b

w/1.5, and d

1/1.0. Tassios et al.22 have

tested a 5 in. × 20 in. (125 mm × 500 mm) coupling beam with a span-to-depth ratio of 1.0 and a 5 in. × 12 in. (125 mm × 300 mm) beam with a span-to-depth ratio of 1.7. The spacing of transverse reinforcement around the diagonal reinforcement was 2 in. (50 mm), 5.0d

b, b

w/2.5, and d

1/1.3. Setting aside the

difference in loading protocol, all four specimens exhibited negligible strength degradation up to total rotations of 5%.

Galano and Vignoli23 had tested two 6 in. × 16 in. (150 mm × 410 mm) coupling beams with a span-to-depth ratio of 1.5. The spacing of transverse reinforcement around the diagonal rein-

Figure 2. This is an example of transverse reinforcement in columns.Source: Reprinted by permission from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) (Farmington Hills, MI: ACI, 2008) p. 341, Figure R21.6.4.2.

6db extension

The dimension xi from centerline to centerline of tie legsis not to exceed 14 inches. The term hx used in equation21-2 is taken as the largest value of xi.

Consecutive crossties engagingthe same longitudinal bar havetheir 90-degree hooks onopposite sides of column

6db ≥ 3 in. Ash2

Ash1

bc2

bc1

xi

xi

xi xi xi

Page 31: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS10

21.9.7.4(c) for such relaxation.

ACI 318 Subcommittee H also explored whether confinement of the entire beam section might be a suitable alternative. Examples of this detailing in practice were identified. It was noted that this was the approach used successfully in early PCA tests.24 This alternative detailing approach has now been incorporated into ACI 318-08 (see section 21.9.7.4[d]). The organization and presentation of

forcement was 4 in. (100 mm), 10db, b

w/1.5, and d

1/1.3. These

specimens experienced buckling of the diagonal reinforcement at total rotations below 3%. It should be emphasized that the trans-verse reinforcement around the diagonal was spaced at 10d

b.

The results suggest that the transverse reinforcement around the diagonals need not be spaced at one quarter the minimum dimension of the confined section as long as the spacing does not exceed 6d

b. Thus some relaxation of the spacing

requirement appears to be justified. See ACI 318-08 section

Figure 3. Coupling beams are shown with diagonally oriented reinforcement. Wall boundary reinforcement is shown on one side only for clarity. Source: Reprinted by per-mission from Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08) (Farmington Hills, MI: ACI, 2008) p. 355, Figure R21.9.7.

Avd = total areaof reinforcementin each group ofdiagonal bars

Transverse reinforcementspacing measured perpendicularto the axis of the diagonal barsnot to exceed 14 in.

≥ bw /2

bw

Note:For clarity, only part of the requiredreinforcement is shown on eachside of the line of symmetry.

Line

of

sym

met

ry

Elevation Section A-A

Horizontal beamreinforcement atwall does notdevelop fy

Wall boundaryreinforcement

A

A

h

α

ln

Avd = total areaof reinforcementin each group ofdiagonal bars

db

Transverse reinforcementspacing not to exceed 8 in.

Transversereinforcementspacing not toexceed 8 in.

Note: Consecutive crossties engaging the same logitudinalbar have their 90-degree hooks on opposite sides of beam.

Note: For clarity in the elevation view, only part of the total required reinforcement is shown on each side of the line of symmetry.

(a) Confinement of individual diagonals.

(b) Full confinement of diagonally oriented reinforcement. Wall reinforcement shown on one side only for clarity.

Note:For clarity, only part of the requiredreinforcement is shown on eachside of the line of symmetry.

Line

of

sym

met

ry

Elevation

Section B-B

Horizontal beamreinforcement atwall does notdevelop fy

Spacing notexceeding smallerof 6 in. and 6db

Wall boundaryreinforcement

B

B

h

α

ln

Page 32: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S11PCI Journal | Specia l Supplement

Special structural walls made with precast concrete

A change made to section 21.10 now allows the use of unbonded, post-tensioned precast concrete walls, coupled or uncoupled, as special structural walls, provided that the requirements of ACI ITG-5.125 are satisfied.

Testing and analysis26–28 have shown that, with appropriate limitations, unbonded post-tensioned precast concrete walls, coupled or uncoupled, can exhibit seismic performance equal to or better than that of cast-in-place special reinforced concrete shear walls. ITG-5.1 defines the protocol necessary to establish a design procedure, validated by analysis and laboratory tests, for such precast concrete walls. Provided that the requirements of ITG-5.1 are satisfied, the requirements of section 21.1.1.8 that such walls must “have strength and toughness equal to or exceeding those provided by a comparable monolithic rein-forced concrete structure satisfying the chapter” are met.

Since 2002, ACI 318 has permitted in section 21.8.3 (previous-ly 21.6.3) the use of special moment frames constructed using precast concrete, provided those frames met the requirements of ACI 374.1.18 The object of the recent change to section 21.10 was to allow, in a similar manner, through a systematic program of analysis and laboratory testing, the use of one type of special precast concrete structural walls. For special precast concrete moment frames, section 21.8.3 also contains two requirements related to the details and materials used in test specimens and the design procedure used to proportion test specimens. For walls, those latter two requirements are not needed because they are specifically included in ITG-5.1.

The ITG-5.1 document has been adopted in section 3.8.10 of ACI 318-08. Section 21.10.3 now reads, “Special struc-tural walls constructed using precast concrete and unbonded post-tensioning tendons and not satisfying the requirements of 21.10.2 are permitted provided they satisfy the requirements of ACI ITG-5.1.”

section 21.9.7 have improved. Also, because the bars are diagonal (not longitudinal), and flexural reinforcement is not present, some sections that had been called out in earlier editions of ACI 318 were not strictly correct. These have been corrected.

The following important commentary has been added to section R21.9.7:

Diagonal bars should be placed approximately symmetrically in the beam cross section, in two or more layers. The diagonally placed bars are intended to provide the entire shear and corresponding moment strength of the beam; designs deriving their moment strength from combinations of diagonal and longitudinal bars are not covered by these provisions.

Two confinement options are described. The first option is found in section 21.9.7.4(c). This option is not needed but revisions were made in the 2008 Code to relax spacing of transverse reinforcement confining the diagonal bars, to clarify that confinement is required at the intersection of the diagonals, and to simplify design of the longitudinal and transverse reinforcement around the beam perimeter; beams with these revised details are expected to perform acceptably.

Section 21.9.7.4(d) describes a second option for confinement of the diagonals introduced in the 2008 Code (Figure R21.9.7(b)). This sec-ond option is to confine the entire beam cross section instead of confining the individual di-agonals. This option can considerably simplify field placement of hoops, which can otherwise be especially challenging where diagonal bars intersect each other or enter the wall boundary.

Table 3. Coupling beam detailing requirements of ACI 318-08

ACI 318-08 section

21.9.7.1 21.9.7.3 21.9.7.2

Conditions (ln /h) > 4, no limit on Vu (ln /h) < 4, no limit on Vu (ln /h) < 2 and Vu > 4

fc' Acw

Conventional reinforcement per ACI 318-08 section 21.5

Required* Not mentioned† Not permitted

Diagonal reinforcement per ACI 318-08 section 21.9.7.4

Not permitted Permitted Required

*The provisions of sections 21.5.1.3 and 21.5.1.4 need not be satisfied if it can be shown that the beam has adequate lateral stability. †Only sections 21.5.2 through 21.5.4 need be satisfied. Note: Acw = area of concrete section of an individual pier, horizontal wall segment, or coupling beam resisting shear; fc

' = design compressive strength of concrete; h = overall thickness or height of member; ln = length of clear span measured face to face of supports; Vn = nominal shear strength; Vu = factored shear force at section.

Page 33: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS12

of forces to collector elements and to the vertical elements of the lateral-force-resisting system.

21.11.3.2—Elements of a structural diaphragm system that are subjected primarily to axial forces and used to transfer diaphragm shear or flexural forces around openings or other discontinuities, shall comply with the require-ments for collectors in 21.11.7.5 and 21.11.7.6.

Any reference to continuous load path has been eliminated from section 21.11.4, “Cast-in-Place Composite-Topping Slab Diaphragm,” because the topic is now covered in section 21.11.3.

Section 21.11.7.2 has been changed for clarity to “Bonded tendons used as reinforcement to resist col-lector forces or diaphragm shear or flexural tension.”

Section 21.11.7.3 now reads, “All reinforcement used to resist collector forces, diaphragm shear, or flexural tension.”

References to structural truss elements, struts, ties, and diaphragm chords have been eliminated from section 21.11.7.5.

The former sections 21.9.8.1 and 21.9.8.2 have now been replaced by section 21.11.8, “Flexural Strength,” which reads, “Diaphragms and por-tions of diaphragms shall be designed for flexure in accordance with 10.2 and 10.3 except that the nonlinear distribution of strain requirements of 10.2.2 for deep beams need not apply. The effects of openings shall be considered.”

This is an important change because flexure is no longer supposed to be resisted by the boundary ele-ment reinforcement only, as was implied by earlier editions of ACI 318.

A new commentary section R21.10.3 has also been added.

Structural diaphragms and trusses

Terminology and design requirements for diaphragms and trusses have been updated through changes in sections 21.1, “Definitions,” and 21.11, “Structural Diaphragms and Trusses.” ACI 318-05 sections 21.9.2 and 21.9.3, as written, implied that a complete transfer of forces was required only for composite-topping slab diaphragms, not for noncomposite diaphragms. A new section, 21.11.3, has been added to clarify that this is required for all diaphragms. Structural trusses are separated from diaphragms because requirements differ and separating them clarifies the requirements.

In sections 21.1, in the definition of boundary elements, any reference to diaphragms has been eliminated. Boundary ele-ments are now for structural walls only.

The definition of collector element has been revised to “Ele-ment that acts in axial tension or compression to transmit seismic forces within a structural diaphragm or between a structural diaphragm and a vertical element of the lateral-force-resisting system.”

The definition of structural diaphragm has been revised to clarify that it transmits forces to “the vertical elements of the lateral-force-resisting system,” rather than to “lateral-force-resisting members.”

The definitions of strut and tie elements have been deleted. Section 21.11.2, “Design Forces,” which is new in ACI 318-08, reads, “The earthquake design forces for structural diaphragms shall be obtained from the legally adopted general building code using the applicable provisions and load combinations.”

New section 21.11.3, “Seismic Load Path,” reads:

21.11.3.1—All diaphragms and their connections shall be proportioned and detailed to provide for a complete transfer

Table 4. Coupling beam detailing requirements of ACI 318-05

ACI 318-05 section

21.7.7.1 21.7.7.2 21.7.7.3

Conditions (ln /h) > 4, no limit on Vu (ln /h) < 4, no limit on Vu (ln /h) < 2 and Vu > 4

fc' Acw

Conventional reinforcement per ACI 318-05 section 21.3

Required Not mentioned Not permitted

Diagonal reinforcement per ACI 318-05 section 21.7.7.4

Not permitted Permitted Required

Note: Acw = area of concrete section of an individual pier, horizontal wall segment, or coupling beam resisting shear; fc' = design compressive

strength of concrete; h = overall thickness or height of member; ln = length of clear span measured face to face of supports; Vn = nominal shear strength; Vu = factored shear force at section.

Page 34: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S13PCI Journal | Specia l Supplement

The new section 21.11.11, “Structural Trusses,” now reads:

21.11.11.1—Structural truss elements with compressive stresses exceeding 0.2 fc

' at any section shall have transverse reinforcement, as given in 21.6.4.2 through 21.6.4.4 and 21.6.4.7, over the length of the element.

21.11.11.2—All continuous reinforcement in structural truss elements shall be developed or spliced for f

y in tension.

A valuable new commentary section in R21.11.2 was added. There are other significant additions to and deletions from the commentary on section 21.11. Notable among these are the additions to section R21.11.8.

Diaphragm shear strength

Studies of precast concrete parking structures fol-lowing the 1994 Northridge earthquake27 indicated that composite topping slab diaphragms depend on shear friction to transmit inertial forces to the verti-cal elements of the lateral-force-resisting system. The results of this research were used to develop ACI 318-05 Eq. (21-11) and are summarized in ACI 318-05 commentary section R21.9.7. How-ever, ACI 318-05 Eq. (21-11) referred to distrib-uted transverse reinforcement within the diaphragm (for consistency with ACI 318-05 Eq. [21-10]) rather than to distributed longitudinal reinforce-ment. When the provisions in ACI 318-05 section 21.9.7.2 were originally developed, it was assumed that the sentence “The required web reinforcement should be distributed uniformly in both directions” was sufficient to ensure that the same amount of re-inforcement was used in both the longitudinal and the transverse directions. There were subsequent indications that clarification was needed.

ACI 318-05 section 21.9.7.3 (now 21.11.9.3) has been revised to directly refer to shear friction reinforcement. Both boundary and distributed reinforcement in the topping slab are assumed to contribute to the shear strength of the topping slab diaphragm, but connectors between the precast concrete elements are not included at this time.

Section 21.11.9.1 (formerly 21.9.7.1) has added the following text below Eq. (21-10): “For cast-in-place topping slab diaphragms on precast floor or roof members, A

cv shall be computed using the

thickness of topping slab only for noncomposite topping slab diaphragms and the combined thick-ness of cast-in-place and precast elements for

composite topping slab diaphragms. For composite topping slab diaphragms, the value of fc

' used to determine Vn shall not

exceed the smaller of fc' for the precast members and fc

' for the topping slab.”

Sections 21.11.9.3 and 21.11.9.4 now read:

21.11.9.3—Above joints between precast elements in noncomposite and composite cast-in-place topping slab diaphragms, V

n shall not exceed

Vn = A

vf fy μ

where Avf

is total area of shear friction reinforcement within topping slab, including both distributed and boundary reinforcement, that is oriented perpendicular to joints in the precast system and coefficient of friction, μ, is 1.0λ where λ is given in 11.6.4.3. At least one-half of A

vf shall be uniformly distributed along the length of the

potential shear plane. Area of distributed reinforcement in topping slab shall satisfy 7.12.2.1 in each direction.

21.11.9.4—Above joints between precast elements in non-composite and composite cast-in-place topping slab dia-phragms, V

n shall not exceed the limits in 11.6.5 where A

c

is computed using the thickness of the topping slab only.

Commentary section R21.9.7 has been modified to explain the changes.

Gravity columns

An error has been corrected in section 21.13, “Members Not Designated as Part of the Seismic-Force-Resisting System.” Consider the case of a gravity column where the effects of de-sign displacements are not explicitly checked and the member has axial load exceeding A

gfc

' /10. According to ACI 318-05 section 21.11.3.3, the member need not satisfy ACI 318-05 section 21.4.3.2 and, therefore, the column lap splice might be located at the base of the column. However, if the effects of the design displacements were checked, then according to ACI 318-05 section 21.11.2.2, the member had to satisfy ACI 318-05 section 21.4.3.2 and the location of the column splice had to be within the center of the column length.

In other words, if a gravity column might yield under the design displacements, the designer could splice the longitudi-nal reinforcement at any location, but if the column was not expected to yield, the splice had to be located near midheight. This did not make sense.

This flaw traced back to ACI 318-95. Before the 1995 edi-tion, lap-splice locations were not prescribed for members that were not proportioned to resist forces induced by earth-quake motions. The flaw has been corrected in ACI 318-08. ACI 318-05 section 21.11.2.2 used to require members with factored gravity axial forces exceeding A

gfc

' /10 to satisfy sec-

Page 35: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS14

tions 21.4.3, 21.4.4.1(c), 21.4.4.3 and 21.4.5. ACI 318-08 sec-tion 21.13.3.2 now requires such columns to satisfy sections 21.6.3.1, 21.6.4.2, and 21.6.5. ACI 318-05 section 21.11.3.3 required members with factored gravity axial forces exceed-ing A

gfc

' /10 to satisfy sections 21.4.3.1, 21.4.4, 21.4.5, and 21.5.2.1. ACI 318-08 section 21.13.4.3 now requires such col-umns to satisfy sections 21.6.3, 21.6.4, 21.6.5, and 21.7.3.1.

Conclusion

Changes to chapter 21 of ACI 318-08 have been summarized and discussed in this part of the current series of papers on significant changes from ACI 318-05 to ACI 318-08. It is clear that the changes to chapter 21 are significant in number and quite substantive in nature. The changes include a com-plete reorganization of the chapter and a change in its title.

References

1, American Concrete Institute (ACI) Committee 318. 2005. Building Code Requirements for Structural Con-crete (ACI 318-05) and Commentary (ACI 318R-05). Farmington Hills, MI: ACI.

2. ACI Committee 318. 2008. Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08). Farmington Hills, MI: ACI.

3. International Code Council. 2006. International Building Code. Washington, DC: International Code Council.

4. Structural Engineering Institute. 2005. Minimum Design Loads for Buildings and Other Structures. ASCE 7-05. Reston, VA: American Society of Civil Engineers (ASCE).

5. Building Seismic Safety Council (BSSC). 2003. NEHRP Recommended Provisions for the Development of Seis-mic Regulations for New Buildings and Other Structures. Washington, DC: BSSC.

6. Muguruma, H., and F. Watanabe. 1990. Ductility Improvement of High-Strength Concrete Columns with Lateral Confinement. In Proceedings, Second Inter-national Symposium on High-Strength Concrete, pp. 47–60. Detroit, MI: American Concrete Institute (ACI).

7. Muguruma, H., M. Nishiyama, F. Watanabe, and H. Tanaka. 1991. Ductile Behavior of High-Strength Con-crete Columns Confined by High-Strength Transverse Reinforcement. In Evaluation and Rehabilitation of Con-crete Structures and Innovations in Design, pp. 877–891. Detroit, MI: ACI.

8. Sugano, S., T. Nagashima, H. Kimura, A. Tamura, and A. Ichikawa. 1990. Experimental Studies on Seismic Behavior of Reinforced Concrete Members of High

Strength Concrete. In Proceedings, Second International Symposium on High-Strength Concrete, pp. 61–87. Detroit, MI: ACI.

9. Budek, A., M. Priestley, and C. Lee. 2002. Seismic Design of Columns with High-Strength Wire and Strand as Spiral Reinforce-ment. ACI Structural Journal, V. 99, No. 5 (September–October): pp. 660–670.

10. American Society for Testing and Materi-als (ASTM) Subcommittee A01.05. 2006. Standard Specification for Deformed and Plain, Low-carbon, Chromium, Steel Bars for Concrete Reinforcement. ASTM A1035/A1035M-06. West Conshohocken, PA: ASTM.

11. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforce-ment. ASTM A615/A615M-06A. West Con-shohocken, PA: ASTM.

12. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Rein-forcement. ASTM A706/A706M-06A. West Conshohocken, PA: ASTM.

13. ASTM Subcommittee A01.05. 2006. Stan-dard Specification for Deformed and Plain Stainless-Steel Bars for Concrete Reinforce-ment. ASTM A955/A955M-06A. West Con-shohocken, PA: ASTM.

14. Pan, A., and J. P. Moehle. 1989. Lateral Dis-placement Ductility of Reinforced Concrete Flat Plates. ACI Structural Journal, V. 86, No. 3 (May–June): pp. 250–258.

15. ACI-ASCE Committee 352. 2002. Recom-mendations for Design of Beam-Column Con-nections in Monolithic Reinforced Concrete Structures (ACI 352R-02). Farmington Hills, MI: ACI.

16. Meinheit, D. F., and J. O. Jirsa. 1981. Shear Strength of R/C Beam-Column Connections. Journal of the Structural Division, V. 107, No. ST11 (November): pp. 2227–2244.

17. ACI Innovation Task Group 1. 2003. Special Hybrid Moment Frames Composed of Discrete-ly Jointed Precast and Post-Tensioned Con-crete Members (ITG-1.2-03) and Commentary (ITG-1.2R-03). Farmington Hills, MI: ACI.

Page 36: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

S15PCI Journal | Specia l Supplement

18. ACI Committee 374. 2005. Acceptance Cri-teria for Moment Frames Based on Structural Testing (ACI 374.1-05) and Commentary (ACI 374.1R-05). Farmington Hills, MI: ACI.

19. International Conference of Building Officials (ICBO). 1994, 1997. Uniform Building Code. Whittier, CA: ICBO.

20. Thomsen, J. H., and J. W. Wallace. 2004. Displacement Design of Slender Reinforced Concrete Structural Walls—Experimental Verification. Journal of Structural Engineer-ing, V. 130, No. 4: pp. 618–630.

21. Paulay, T., and J. R. Binney. 1974. Diago-nally Reinforced Coupling Beams of Shear Walls. In Shear in Reinforced Concrete, pp. 579–598. Detroit, MI: ACI.

22. Tassios, T., M. Moretti, and A. Bezas. 1996. On the Behavior and Ductility of Reinforced Concrete Coupling Beams of Shear Walls. ACI Structural Journal, V. 93, No. 6 (Novem-ber–December): pp. 711–720.

23. Galano, L., and A. Vignoli. 2000. Seismic Behavior of Short Coupling Beams with Dif-ferent Reinforcement Layouts. ACI Structural Journal, V. 97, No. 6, (November–Decem-ber): pp. 876–885.

24. ACI Innovation Task Group 5. 2007. Accep-tance Criteria for Special Unbonded Post-Tensioned Precast Walls Based on Validation Testing (ITG-5.1-07) and Commentary (ITG-5.1R-07). Farmington Hills, MI: ACI.

25. Priestly, M. J. N., S. Sritharan, J. Conley, and S. Pampanin. 1999. Preliminary Results and Conclusions from the PRESSS Five-Story Precast Concrete Test Building. PCI Journal, V. 44, No. 6 (November–December): pp. 42–67.

26. Perez, F. J., S. Pessiki, R. Sause, and L. W. Lu. Lateral Load Tests of Unbonded Post-Tensioned Precast Concrete Walls. In Large Scale Structural Testing, pp. 161–182. Farm-ington Hills, MI: ACI.

27. Restrepo, J. I. 2002. New Generation of Earthquake Resisting Systems. In Proceed-ings, Fifth fib Congress, Session 6, Osaka, Japan, pp. 41–60.

28. Wood, S. L., J. F. Stantas, and N. M. Hawkins. 2000. Development of New Seismic Design Provisions for Diaphragms Based on the Observed Behavior of Precast Concrete Parking Garages during the 1994 Northridge Earthquake. PCI Journal, V. 45, No. 1, (January–Febru-ary): pp. 50–65.

Notation

Ac = area of concrete section resisting shear transfer

Acv

= gross area of concrete section bounded by web thick-ness and length of section in the direction of shear force considered

Acw

= area of concrete section of an individual pier, horizon-tal wall segment, or coupling beam resisting shear

Ag = gross area of concrete section

Ash

= total cross-sectional area of transverse reinforcement (including crossties) within spacing s and perpendicu-lar to dimension b

c

Avf

= area of shear-friction reinforcement

bc = cross-sectional dimension of member core measured

to the outside edges of the transverse reinforcement composing area A

sh

bw = web width or diameter of circular section

c1 = dimension of rectangular or equivalent rectangular

column, capital, or bracket measured in the direction of the span for which moments are being determined

c2 = dimension of rectangular or equivalent rectangular

column, capital, or bracket measured in the direction perpendicular to c

1

d1 = minimum dimension of confined section containing

diagonal reinforcement

db

= diameter of diagonal reinforcing bars

E = load effects of earthquake or related internal moments and forces

fy = specified yield strength of nonprestressed

reinforcement

fyt = specified yield strength of the transverse reinforcement

fc' = specified compressive strength of concrete

h = overall thickness or height of member

Page 37: Significant changes to ACI 318-08 relative ... - S. K. Ghoshskghoshassociates.com/sk_publication/Changes_ACI_123.pdfACI 318-08 relative to precast/ prestressed concrete: part 1 S.

Specia l Supplement | PCI JournalS16

ln = length of clear span measured face-to-face of supports

lo = length, measured from joint face along axis of struc-

tural member, over which special transverse reinforce-ment must be provided

Pu

= factored axial compressive force at section

R = response modification factor

so = center-to-center spacing of transverse reinforcement

within the length lo

vn = nominal shear stress

Vn = nominal shear strength

Vu = factored shear force at section

λ = modification factor reflecting the reduced mechanical properties of lightweight concrete

µ = coefficient of friction

= strength-reduction factor

About the author

S. K. Ghosh, PhD, FPCI, is president of S. K. Ghosh Associates Inc. in Palatine, Ill.

Synopsis

Significant changes were made since the American Concrete Institute (ACI) Committee 318 published the 2005 Building Code Requirements for Struc-tural Concrete (ACI 318-05) and Commentary (ACI 318R-05). Some of the changes in the upcom-ing 2008 edition are summarized here. In addition to changes affecting conventionally reinforced concrete, provisions affecting precast/prestressed

concrete, including post-tensioned concrete, are enumerated. Only changes to chapter 21 of ACI 318-08 are discussed in this article.

Keywords

ACI 318, codes, structural concrete.

Reader comments