Signature Hinged Door (125mm)
Transcript of Signature Hinged Door (125mm)
Installation Details
SignatureHinged Door(125mm)
THICKNESS TO SUIT(BY BUILDER - 300mm LENGTH)
CAVITY FIXING PACKER
(BY BUILDER)
STEEL LINTEL
TIMBER LINTEL
SARKING
SEALANT
HEAD FLASHING
(DO NOT PACK FIXING)
REVEAL TO SUIT
10mm MIN. CLEARANCE
(BY BUILDER - SEE NOTE)HEAD REVEAL FIXING
(BY BUILDER)
JAMB STUD
JAMB FLASHING
(BY BUILDER - AT FIXING POINTS)JAMB PACKER TO SUIT
(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUIT
NOTE:
JAMB REVEAL FIXING
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE ATFOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
2.2mm STEEL NAIL MIMIMUM.
(200mm LENGTHS - AT HINGE POINTS)EXTENDER FIN 100BA543 (3964)
(BY BUILDER - 1 PER HINGE)
(BY BUILDER - 2 PER FIN EXTENDER)
ARCHITRAVE
INTERIOR LINING
10G x 65mm SCREWFIN EXTENDER FIXING
(2 PER FIN EXTENDER)SCREW SQ 10G x 1.18 WAFER SD SS #283761
ADDITIONAL HINGE FIXINGREMOVE EXISTING & RELACEWITH 10G x 100mm SCREW
HINGE TO SUIT
SIG-HD-02-01 B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819
SIG 125 HD
CDJH 1 : 3
COPYRIGHT 2017
PRODUCT NO:
SCALE:
DRAWING NO:
DRAWN:
DATE:
ISSUE:
01/02/17
BRICK VENEER CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL
Signature Hinged Door (125mm )Installation Details
02-01
(BY BUILDER - 1 PER HINGE)
NOTE:
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
2.2mm STEEL NAIL MIMIMUM.
(BY BUILDER)JAMB FLASHING
(BY BUILDER)
BRICKWORK
REVEAL TO SUIT
SILL FLASHING
(AS PER B.C.A.)
FOOTING
DRAIN SLOTS
(NON-SHRINKING)
INTERNAL FLOOR FINISH
SEALANT
GROUT
(BY BUILDER - AT FIXING POINTS)JAMB PACKER TO SUIT
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUITJAMB REVEAL FIXING
(BY BUILDER - 300mm LENGTH)THICKNESS TO SUITCAVITY FIXING PACKER
(2 PER FIN EXTENDER)SCREW SQ 10G x 1.18 WAFER SD SS #283761
(200mm LENGTHS - AT HINGE POINTS)EXTENDER FIN 100BA543 (3964)
(BY BUILDER - 2 PER FIN EXTENDER)10G x 65mm SCREWFIN EXTENDER FIXING
ADDITIONAL HINGE FIXINGREMOVE EXISTING & RELACEWITH 10G x 100mm SCREW
HINGE TO SUIT
B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 20171 : 3
SIG 125 HD
DRAWN:
DRAWING NO:
PRODUCT NO:
SCALE:C
ISSUE:
DATE:
DJH
SIG-HD-02-02
01/02/17
BRICK VENEER CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL
Signature Hinged Door (125mm )Installation Details
02-02
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
SARKING
(200mm LENGTHS - AT HINGE POINTS)
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
EXTERIOR CLADDING
TIMBER LINTEL
EXTERIOR TRIM
HEAD FLASHING(BY BUILDER)
BA543 (3964)EXTENDER FIN 100
(DO NOT PACK FIXING)
REVEAL TO SUIT
INTERIOR LINING
ARCHITRAVE
JAMB STUD
10mm MIN. CLEARANCE
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUIT
(BY BUILDER - SEE NOTE)
HINGE TO SUIT
HEAD REVEAL FIXING
JAMB REVEAL FIXING
NOTE:
(BY BUILDER - 1 PER HINGE)WITH 10G x 100mm SCREW
(BY BUILDER - AT FIXING POINTS)JAMB PACKER TO SUIT
(BY BUILDER)JAMB FLASHING
REMOVE EXISTING & RELACE
(BY BUILDER - 2 PER FIN EXTENDER)10G x 65mm SCREWFIN EXTENDER FIXING
ADDITIONAL HINGE FIXING
83761SCREW SQ 10G x 1.18 WAFER SD SS #2(2 PER FIN EXTENDER)
B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 20171 : 3
ESS 100 HD
DRAWN:
DRAWING NO:
PRODUCT NO:
SCALE:C
ISSUE:
DATE:
DJH
ESS-HD-02-03
01/02/17
CLADDING CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL
Signature Hinged Door (125mm )Installation Details
02-03
ISSUE:SIG-HD-02-04 B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
C COPYRIGHT 2016
DATE:SIG 125 HD
ABN 78 010 409 819
PRODUCT NO:
SCALE: 1 : 3DJHDRAWN:
DRAWING NO:
20/09/16
CLADDING CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL
BA543 (3964)EXTENDER FIN 100
2.2mm STEEL NAIL MIMIMUM.450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
(200mm LENGTHS - AT HINGE POINTS)
INTERNAL FLOOR FINISH
(AT FIXING POINTS)
HINGE TO SUIT
(BY BUILDER - 2 PER FIN EXTENDER)
(BY BUILDER)
FOOTING
(BY BUILDER)
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A
SEALANT
(BY BUILDER)
SILL FLASHING
GROUT
EXTERIOR TRIM
JAMB REVEAL FIXING
(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUIT
10G x 65mm SCREWFIN EXTENDER FIXING
JAMB PACKER
SILL SUPPORT
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE ATNOTE:
(BY BUILDER - 1 PER HINGE)WITH 10G x 100mm SCREWREMOVE EXISTING & RELACEADDITIONAL HINGE FIXING
83761SCREW SQ 10G x 1.18 WAFER SD SS #2(2 PER FIN EXTENDER)
Signature Hinged Door (125mm )Installation Details
02-04
B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 20171 : 3
SIG 125 HD
DRAWN:
DRAWING NO:
PRODUCT NO:
SCALE:C
ISSUE:
DATE:
DJH
SIG-HD-02-05
01/02/17
CAVITY BRICK CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
(BY BUILDER)HEAD FLASHING
INTERNAL LINING ADHESIVE
STEEL LINTEL
(BY BUILDER)JAMB FLASHING
INTERNAL LINING
(TO PINCH FIN)
BRICKWORK
NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
HINGE TO SUIT
86716TIE BRICK FLAT CAVITY SIG LASEROR85856TIE FLAT BRICK 100/166(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)
86716 (TRIMMED)TIE BRICK FLAT CAVITY SIG LASER(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)
Signature Hinged Door (125mm )Installation Details
02-05
1 : 3
DRAWING NO: ISSUE:SIG-HD-02-06 B
DJH Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2017
PRODUCT NO:
SCALE:C
DRAWN:
DATE:SIG 125 HD 01/02/17
CAVITY BRICK CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL
FOOTING
INTERNAL LINING ADHESIVE
SILL FLASHING
(NON-SHRINKING)
(BY BUILDER)
BRICKWORK
(AS PER B.C.A.)
(BY BUILDER)
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
ARCHITRAVE
SEALANT
DRAIN SLOTS
INTERNAL LINING
JAMB FLASHING
2.2mm STEEL NAIL MIMIMUM.300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A
INTERNAL FLOOR FINISH
NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
GROUT
HINGE TO SUIT
86716TIE BRICK FLAT CAVITY SIG LASEROR85856TIE FLAT BRICK 100/166(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)
86716 (TRIMMED)TIE BRICK FLAT CAVITY SIG LASER(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)
Signature Hinged Door (125mm )Installation Details
02-06
B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 20171 : 3
SIG 125 HD
DRAWN:
DRAWING NO:
PRODUCT NO:
SCALE:C
ISSUE:
DATE:
DJH
SIG-HD-02-07
01/02/17
BLOCKWORK CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL
(SEAL TO OPENING & FRAME)
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
(SEE NOTE)
REINFORCING BAR
BLOCKWORK
(INISDE ANGLE ONLY - SEE NOTE)
AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
HEAD ANGLE FIXINGS ATREQUIRED CENTRES
HINGE TO SUIT
SEALANT
ANGLE 40 x 25 x 2.7mmBX336 (2304)
INTERNAL LINING ADHESIVE
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE ATFOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
ANCHOR FIXING
INTERNAL LINING
ANGLE 25 x 20 x 1.5(SEAL TO OPENING & FRAME)
BX123 (2369)
(SEE NOTE)
NOTE:SURFACE OF BLOCKS TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TOPREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY
JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES(SEE NOTE)
Signature Hinged Door (125mm )Installation Details
02-07
BX336 (2304)
(SEE NOTE)
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
BX123 (2369)ANGLE 25 x 20 x 1.5(SEAL TO OPENING & FRAME)
AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
INTERNAL LINING
ANGLE 40 x 25 x 2.7mm
(INISDE ANGLE ONLY - SEE NOTE)
INTERNAL LINING ADHESIVE
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
(SEE NOTE)
REINFORCING BAR
BLOCKWORK
FOOTING
INTERNAL FLOOR FINISH
(NON-SHRINKING)
(SEAL TO OPENING & FRAME)
ANCHOR FIXING
GROUT
SEALANT
(AS PER B.C.A. SEE BELOW)TANKING ON ALL OPENING SURFACES
NOTE:SURFACE OF BLOCKS TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TOPREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY
JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES
HINGE TO SUIT
ISSUE:SIG-HD-02-08 B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
C COPYRIGHT 2017
DATE:SIG 125 HD
ABN 78 010 409 819
PRODUCT NO:
SCALE: 1 : 3DJHDRAWN:
DRAWING NO:
01/02/17
BLOCKWORK CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL
Signature Hinged Door (125mm )Installation Details
02-08
1 : 3
DRAWING NO: ISSUE:SIG-HD-02-09 B
DJH Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2017
PRODUCT NO:
SCALE:C
DRAWN:
DATE:SIG 125 HD 01/02/17
CONCRETE CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL
ANGLE 25 x 20 x 1.5
BX336 (2304)
INTERNAL LINING
(SEAL TO OPENING & FRAME)
PREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY
ANGLE 40 x 25 x 2.7mm
(SEE NOTE)
(SEAL TO OPENING & FRAME)
BX123 (2369)
HEAD ANGLE FIXINGS ATREQUIRED CENTRES
SURFACE OF CONCRETE TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TO
CONCRETE PANEL
FIXING TYPES & CENTRES TO BE PROJECT SPECIFIC, REFER TO SPECIFICATION AND/OR ENGINEEER.
AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
INTERNAL LINING ADHESIVE
HINGE TO SUIT
NOTE:
(SEE NOTE)
JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES(SEE NOTE)
Signature Hinged Door (125mm )Installation Details
02-09
PREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY
NOTE:SURFACE OF CONCRETE TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TO
INTERNAL LINING ADHESIVE
PACKER
(INSIDE ANGLE ONLY - SEE NOTE)
HINGE TO SUIT
BX123 (2369)
FIXING TO SUIT
FIXING TYPES & CENTRES TO BE PROJECT SPECIFIC, REFER TO SPECIFICATION AND/OR ENGINEEER.
AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
BACKING ROD
ANGLE 40 x 25 x 2.7mm
SUBSILL '15' 100
INTERNAL LINING
BX336 (2304)
(SEAL TO OPENING & FRAME)
ANCHOR FIXING
ANGLE 25 x 20 x 1.5(SEAL TO OPENING & FRAME)
SILL SEALED TO SUBSILL
SEAL SUBFRAME
URETHANE SEALANT
CONCRETE PANEL
83353
(SEE NOTE)
BE015 (3353)
(SEAL OVER FIXING HEAD - SEE NOTE)
JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES(SEE NOTE)
ISSUE:SIG-HD-02-10 B
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
C COPYRIGHT 2017
DATE:SIG 125 HD
ABN 78 010 409 819
PRODUCT NO:
SCALE: 1 : 3DJHDRAWN:
DRAWING NO:
01/02/17
CONCRETE CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL
Signature Hinged Door (125mm )Installation Details
02-10
(FIT INTO SUBSILL BEFORE FIXING)
TANKING APPLIED TO OPENING SURFACE
SUBSILL FIXING
PACKING AT FIXING POINTS
DAM ANGLE TO SUIT
(TYPE & QUANTITY PROJECT SPECIFIC)
1. INSTALL SUBSILL INTO OPENING WITH DAM ANGLE FITTED. PACK SUBSILL LEVELTHEN FIX TO STRUCTURE. SEAL SUBSILL ENDS TO STRUCTURE.
(BY BUILDER)
SUBSILL TO SUIT(SEAL ENDS TO OPENING)
1 : 4
DRAWING NO: ISSUE:SIG-HD-02-11 A
DJH Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2012
PRODUCT NO:
SCALE:C
DRAWN:
DATE:SIG 125 HD 20/11/12
SUBSILL DAM ANGLE INSTALLATION
(SEAL TO OPENING & SUBSILL)
SEAL ALL JOINTS BETWEEN ANGLE AND SUBSILL. SEAL OVER FIXINGS AND UNDER SUB SILL TO STRUCTURE.
BACKING ROD
SEAL OVER FIXINGS
DAM ANGLE TO SUIT
SEAL
2.APPLY SEALANT TO VERTICAL FACE OF DAM ANGLE AND ALSO TO THE FLOOR OF THE SUBSILL.POSITION DAM ANGLE AGAINST STRUCTURE. SEAL ALL JOINTS BETWEEN ANGLE AND SUBSILL.
TANKING APPLIED TO OPENING SURFACE(BY BUILDER)
Signature Hinged Door (125mm )Installation Details
02-11
BX336 (2304)ANGLE 40 x 25 x 2.7mm(FIXING ANGLE - SEAL TO OPENING & WINDOW)
Q2481 (2111)ANGLE 25 x 20 x 1.4(TRIM ANGLE - SEAL TO OPENING & WINDOW)
BE015 (3353)SUBSILL '15' 100
83353SEAL SUBFRAME
ANGLE DAM 100(SEAL TO OPENING & SUBSILL)
83611
SILICONE SEAL ALL EXPOSED GAPSBETWEEN SUBSILL, DAM ANGLE & ANGLES
SIG-HD-02-12 A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819
SIG 125 HD
CDJH 1 : 1.5
COPYRIGHT 2012
PRODUCT NO:
SCALE:
DRAWING NO:
DRAWN:
DATE:
ISSUE:
20/11/12
SUBSILL DAM ANGLE INSTALLATION WITHE FIXING & TRIM ANGLES
Signature Hinged Door (125mm )Installation Details
02-12