SIE AND PERFORMANCE SUMMARY GLAING …media.pella.com/professional/adm/Fiberglass/F2Casement.pdf ·...
Transcript of SIE AND PERFORMANCE SUMMARY GLAING …media.pella.com/professional/adm/Fiberglass/F2Casement.pdf ·...
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-1
CASEMENT
SECTION DIRECTORY
The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information.
SIZE AND PERFORMANCE SUMMARY
GLAZING PERFORMANCE
GRILLE PROFILES AND PATTERNS
SIZE TABLES
DESIGN DATA
DETAILED PRODUCT DESCRIPTION
CROSS SECTIONS
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-2
CASEMENT
Pella® Impervia® Casement
windows are perfect for contemporary or traditional applications
and feature all the Pella innovations you demand. All frame types
and sash material feature Duracast® fiberglass composite, Pella’s
patented, five layer, engineered fiberglass composite. Duracast
fiberglass composite is the strongest, most durable material
available in windows and patio doors. Each window uses three-
way reinforced corners for increased strength. All frame and sash
corners are locked in place with corner locks and injected with
a dual purpose sealant/adhesive for long-lasting performance.
Pella Impervia products are prefinished with powder-coat paint.
This paint meets the stringent AAMA 623 standards. Powder-
coat paint is resistant to dents, scratches and damaging UV light.
Duracast fiberglass composite can withstand extreme heat (over
200˚ F), intense cold (-40˚ F), and is seacoast worthy.
BRAND SUMMARY
Casement
BLOCK FRAME
The 3-1/4" deep block frame is our most versatile frame. Units can be installed in masonry openings using installation clips, concealed jamb screws or in wood frame openings using optional fins. Units can also be field-joined together. Our block frames may easily be used as a replacement window without removing the existing frame or damaging the exterior.
INTEGRAL NAILING FIN
The integral nailing fin features a standard continuous fin, adding a protective weather barrier to the frame itself and allowing for smooth installation.
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-3
CASEMENT
S = Standard; O = Optional; (—) = Not available
(1) See Design Data pages in this section for specific product performance class and grade values.
(2) The higher the level, the greater the product’s ability to resist forced entry.
(3) ASTM E 1425 defines standard sizes for acoustical testing. Ratings achieved at that size are representative of all sizes of the same configuration.
Size and Performance Data BLOCK FRAME
INTEGRAL NAILING FIN
SIZES
Standard Vent/Fixed l l
Standard Fixed Companion Sizes l l
Transom Sizes l l
Egress Sizes l l
Special Sizes l l
PERFORMANCE 1
Meets or Exceeds AAMA / WDMA Ratings C-LC45 – C-LC50Hallmark Certified
C-LC45 – C-LC50Hallmark Certified
Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure) 0.05 0.05
Water Resistance 7.5 psf 7.5 psf
Design Pressure 45 – 50 psf 45– 50 psf
OTHER PERFORMANCE CRITERIA
Forced Entry Resistance Level (Minimum Security Grade) 2 40 40
Maximum Operating Force (lb) Initiate Motion / Maintain Motion 15 / 6 15 / 6
PRODUCT SELECTION GUIDE
Size and Performance Data / Features and Options
Sound Transmission Class - OITC
SOUND TRANSMISSION CLASS AND OUTDOOR-INDOOR TRANSMISSION CLASS
Product Frame Size Tested 3
Glazing SystemSTC
RatingOITC
RatingOverall Glazing Thickness
Exterior Glass Thickness
Interior Glass Thickness
VENT
23-1/2" x 59-1/2" 11/16" 2.5mm 2.5mm 25 22
23-1/2" x 59-1/2" 11/16" 3mm 5mm 32 28
23-1/2" x 59-1/2" 11/16" 3mm 6mm Laminated 32 28
FIXED
47-1/2" x 59-1/2" 11/16" 3mm 3mm 27 23
47-1/2" x 59-1/2" 11/16" 3mm 5mm 31 26
47-1/2" x 59-1/2" 11/16" 3mm 6mm Laminated 32 27
47-1/2" x 59-1/2" 11/16" 4mm 7mm Laminated 33 29
Rev. 04/26/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-4
CASEMENT
BLOCK FRAME INTEGRAL NAILING FIN
GLAZING
Glazing Type
Dual-pane Insulating Glass S S
Insulated Glass Options / Low-E Types
Clear Insulating Glass (no Low-E coating) S S
Advanced Low-E Insulating Glass O O
SunDefense™ Low-E Insulating Glass O O
AdvancedComfort Low-E Insulating Glass O O
NaturalSun Low-E Insulating Glass O O
Additional Glass Options
Annealed Glass S S
Tempered Glass O O
Noise reduction glass (3/5mm, 4/6mm combinations) O O
Noise Reduction laminated glass (non-impact) O O
Tinted glass (Bronze, Gray, Green) Advanced Low-E O O
Obscure Glass1 O O
Gas Fi l l / High Alt i tude
Argon S S
High Altitude O O
High Altitude with argon O O
EXTERIOR / INTERIOR
Powder-Coat White S S
Powder-Coat Tan, Brown, Black, or Morning Sky Gray O O
Dual-color (All exterior colors available with White interior) O —
HARDWARE
Match interior finish S S
Satin Nickel, Bright Brass or Oil-Rubbed Bronze
O O
Sash Locks
SureLock® System S S
Unison Lock System 2 S S
SCREENS
Conventional Black Fiberglass O O
InView™ screen O O
GRILLES
Gri l les-Between-the-Glass
Traditional, Prairie, Top Row and Custom - Equally Divided O O
PRODUCT SELECTION GUIDE
Features and Options
S = Standard; O = Optional; (—) = Not available
(1) Contact your local Pella sales representative for current offering.
(2) Unit size determines availability.
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-5
CASEMENT
GLAZING PERFORMANCE – TOTAL UNIT
Vent Units
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
VENT UNITS N NC SC S 1 2 311/16" Clear IG PEL-N-150-00573-00001 2.5 2.5 air 0.44 0.55 0.57 44
with grilles-between-the-glass PEL-N-150-00573-00002 0.44 0.50 0.52 44
11/16" Clear IG PEL-N-150-00573-00003 3 3 air 0.44 0.55 0.57 44 with grilles-between-the-glass PEL-N-150-00573-00004 0.44 0.50 0.52 44
11/16" Advanced Low-E IG PEL-N-150-00604-00001 2.5 2.5 argon 0.28 0.26 0.49 60 19 with grilles-between-the-glass PEL-N-150-00604-00002 0.28 0.24 0.44 60 18
11/16" Advanced Low-E IG PEL-N-150-00604-00003 3 3 argon 0.28 0.26 0.49 60 19 with grilles-between-the-glass PEL-N-150-00604-00004 0.28 0.24 0.44 60 18
11/16" SunDefense™ IG PEL-N-150-00618-00001 2.5 2.5 argon 0.28 0.20 0.45 60 16 with grilles-between-the-glass PEL-N-150-00618-00002 0.28 0.18 0.41 60
11/16" SunDefense™ IG PEL-N-150-00618-00003 3 3 argon 0.28 0.20 0.45 60 16 with grilles-between-the-glass PEL-N-150-00618-00004 0.28 0.18 0.41 60
11/16" AdvancedComfort Low-E IG PEL-N-150-00630-00001 2.5 2.5 argon 0.25 0.26 0.48 47 23 with grilles-between-the-glass PEL-N-150-00630-00002 0.25 0.24 0.43 47 22
11/16" AdvancedComfort Low-E IG PEL-N-150-00630-00003 3 3 argon 0.25 0.26 0.48 47 23 with grilles-between-the-glass PEL-N-150-00630-00004 0.25 0.24 0.43 47 22
11/16" NaturalSun Low-E IG PEL-N-150-00592-00001 2.5 2.5 argon 0.29 0.49 0.55 59 31 with grilles-between-the-glass PEL-N-150-00592-00002 0.29 0.44 0.50 59 28
11/16" NaturalSun Low-E IG PEL-N-150-00592-00003 3 3 argon 0.29 0.49 0.55 59 31 with grilles-between-the-glass PEL-N-150-00592-00004 0.29 0.44 0.50 59 28
VENT UNITS — WITH FOAM INSULATION11/16" Advanced Low-E IG PEL-N-150-00678-00001 2.5 2.5 argon 0.27 0.26 0.49 60 20
with grilles-between-the-glass PEL-N-150-00678-00002 0.27 0.24 0.44 60 1911/16" Advanced Low-E IG PEL-N-150-00678-00003 3 3 argon 0.27 0.26 0.49 60 20
with grilles-between-the-glass PEL-N-150-00678-00004 0.27 0.24 0.44 60 1911/16" SunDefense IG PEL-N-150-00692-00001 2.5 2.5 argon 0.27 0.20 0.45 61 17
with grilles-between-the-glass PEL-N-150-00692-00002 0.27 0.18 0.41 61 1611/16" SunDefense IG PEL-N-150-00692-00003 3 3 argon 0.27 0.20 0.45 61 17
with grilles-between-the-glass PEL-N-150-00692-00004 0.27 0.18 0.41 61 1611/16" AdvancedComfort Low-E IG PEL-N-150-00704-00001 2.5 2.5 argon 0.24 0.26 0.48 47 24
with grilles-between-the-glass PEL-N-150-00704-00002 0.24 0.24 0.43 47 2311/16" AdvancedComfort Low-E IG PEL-N-150-00704-00003 3 3 argon 0.24 0.26 0.48 47 24
with grilles-between-the-glass PEL-N-150-00704-00004 0.24 0.24 0.43 47 2311/16" NaturalSun Low-E IG PEL-N-150-00666-00001 2.5 2.5 argon 0.28 0.49 0.55 59 32
with grilles-between-the-glass PEL-N-150-00666-00002 0.28 0.44 0.50 59 3011/16" NaturalSun Low-E IG PEL-N-150-00666-00003 3 3 argon 0.28 0.49 0.55 59 32
with grilles-between-the-glass PEL-N-150-00666-00004 0.28 0.44 0.50 59 30
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 05/09/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-6
CASEMENT
GLAZING PERFORMANCE – TOTAL UNIT
Vent Units — High Altitude
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
HIGH ALTITUDE GLAZING N NC SC S 1 2 311/16" (HA) Advanced Low-E IG PEL-N-150-00597-00001 2.5 2.5 air 0.32 0.27 0.49 56
with grilles-between-the-glass PEL-N-150-00597-00002 0.32 0.25 0.44 56
11/16" (HA) Advanced Low-E IG PEL-N-150-00597-00003 3 3 air 0.32 0.27 0.49 56 with grilles-between-the-glass PEL-N-150-00597-00004 0.32 0.25 0.44 56
11/16" (HA) SunDefense IG PEL-N-150-00611-00001 2.5 2.5 air 0.31 0.20 0.45 57 with grilles-between-the-glass PEL-N-150-00611-00002 0.31 0.19 0.41 57
11/16" (HA) SunDefense IG PEL-N-150-00611-00003 3 3 air 0.31 0.20 0.45 57 with grilles-between-the-glass PEL-N-150-00611-00004 0.31 0.19 0.41 57
11/16" (HA) AdvancedComfort Low-E IG PEL-N-150-00625-00001 2.5 2.5 air 0.27 0.26 0.48 43 20 with grilles-between-the-glass PEL-N-150-00625-00002 0.27 0.24 0.43 43 19
11/16" (HA) AdvancedComfort Low-E IG PEL-N-150-00625-00003 3 3 air 0.27 0.26 0.48 43 20 with grilles-between-the-glass PEL-N-150-00625-00004 0.27 0.24 0.43 43 19
11/16" (HA) NaturalSun Low-E IG PEL-N-150-00587-00001 2.5 2.5 air 0.32 0.48 0.55 56 27 with grilles-between-the-glass PEL-N-150-00587-00002 0.32 0.44 0.50 56
11/16" (HA) NaturalSun Low-E IG PEL-N-150-00587-00003 3 3 air 0.32 0.48 0.55 56 27 with grilles-between-the-glass PEL-N-150-00587-00004 0.32 0.44 0.50 56
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION11/16" (HA) Advanced Low-E IG PEL-N-150-00671-00001 2.5 2.5 air 0.31 0.27 0.49 56
with grilles-between-the-glass PEL-N-150-00671-00002 0.31 0.25 0.44 56
11/16" (HA) Advanced Low-E IG PEL-N-150-00671-00003 3 3 air 0.31 0.27 0.49 56 with grilles-between-the-glass PEL-N-150-00671-00004 0.31 0.25 0.44 56
11/16" (HA) SunDefense IG PEL-N-150-00685-00001 2.5 2.5 air 0.30 0.20 0.45 57 with grilles-between-the-glass PEL-N-150-00685-00002 0.30 0.19 0.41 57
11/16" (HA) SunDefense IG PEL-N-150-00685-00003 3 3 air 0.30 0.20 0.45 57 with grilles-between-the-glass PEL-N-150-00685-00004 0.30 0.19 0.41 57
11/16" (HA) AdvancedComfort Low-E IG PEL-N-150-00699-00001 2.5 2.5 air 0.26 0.26 0.48 43 22 with grilles-between-the-glass PEL-N-150-00699-00002 0.26 0.24 0.43 43 20
11/16" (HA) AdvancedComfort Low-E IG PEL-N-150-00699-00003 3 3 air 0.26 0.26 0.48 43 22 with grilles-between-the-glass PEL-N-150-00699-00004 0.26 0.24 0.43 43 20
11/16" (HA) NaturalSun Low-E IG PEL-N-150-00661-00001 2.5 2.5 air 0.31 0.48 0.55 56 28 with grilles-between-the-glass PEL-N-150-00661-00002 0.31 0.44 0.50 56 26
11/16" (HA) NaturalSun Low-E IG PEL-N-150-00661-00003 3 3 air 0.31 0.48 0.55 56 28 with grilles-between-the-glass PEL-N-150-00661-00004 0.31 0.44 0.50 56 26
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 05/09/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-7
CASEMENT
GLAZING PERFORMANCE - TOTAL UNIT
Vent Units
3mm / 5mm Glass
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
VENT N NC SC S 1 2 311/16" Clear IG PEL-N-150-00574-00001 3 5 air 0.45 0.54 0.57 42
with grilles-between-the-glass PEL-N-150-00577-00001 0.45 0.49 0.52 42
11/16" Advanced Low-E IG PEL-N-150-00605-00001 3 5 argon 0.29 0.27 0.49 57 with grilles-between-the-glass PEL-N-150-00608-00001 0.30 0.24 0.44 57
11/16" SunDefense™ IG PEL-N-150-00619-00001 3 5 argon 0.29 0.20 0.45 57 with grilles-between-the-glass PEL-N-150-00622-00001 0.30 0.18 0.41 57
11/16" AdvancedComfort Low-E IG PEL-N-150-00631-00001 3 5 argon 0.26 0.26 0.47 44 22 with grilles-between-the-glass PEL-N-150-00633-00001 0.26 0.24 0.43 44 20
11/16" NaturalSun Low-E IG PEL-N-150-00593-00001 3 5 argon 0.30 0.48 0.55 56 29 with grilles-between-the-glass PEL-N-150-00595-00001 0.31 0.44 0.50 56 26
VENT — WITH FOAM INSULATION11/16" Advanced Low-E IG PEL-N-150-00679-00001 3 5 argon 0.28 0.27 0.49 57 20
with grilles-between-the-glass PEL-N-150-00682-00001 0.29 0.24 0.44 57
11/16" SunDefense IG PEL-N-150-00693-00001 3 5 argon 0.28 0.20 0.45 57 16 with grilles-between-the-glass PEL-N-150-00696-00001 0.29 0.18 0.41 57
11/16" AdvancedComfort Low-E IG PEL-N-150-00705-00001 3 5 argon 0.25 0.26 0.47 44 23 with grilles-between-the-glass PEL-N-150-00707-00001 0.25 0.24 0.43 44 22
11/16" NaturalSun Low-E IG PEL-N-150-00667-00001 3 5 argon 0.29 0.48 0.55 56 31 with grilles-between-the-glass PEL-N-150-00669-00001 0.30 0.44 0.50 56 27
HIGH ALTITUDE GLAZING11/16" (HA) Advanced Low-E IG PEL-N-150-00598-00001 3 5 air 0.33 0.27 0.49 53
with grilles-between-the-glass PEL-N-150-00601-00001 0.34 0.25 0.44 53
11/16" (HA) SunDefense IG PEL-N-150-00612-00001 3 5 air 0.33 0.20 0.45 53 with grilles-between-the-glass PEL-N-150-00615-00001 0.34 0.19 0.41 53
11/16" (HA) AdvancedComfort Low-E IG PEL-N-150-00626-00001 3 5 air 0.28 0.26 0.47 41 19 with grilles-between-the-glass PEL-N-150-00628-00001 0.29 0.24 0.43 41
11/16" (HA) NaturalSun Low-E IG PEL-N-150-00588-00001 3 5 air 0.34 0.48 0.55 52 with grilles-between-the-glass PEL-N-150-00590-00001 0.35 0.44 0.50 52
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION11/16" (HA) Advanced Low-E IG PEL-N-150-00672-00001 3 5 air 0.32 0.27 0.49 53
with grilles-between-the-glass PEL-N-150-00675-00001 0.33 0.25 0.44 53
11/16" (HA) SunDefense IG PEL-N-150-00686-00001 3 5 air 0.32 0.20 0.45 53 with grilles-between-the-glass PEL-N-150-00689-00001 0.33 0.19 0.41 54
11/16" (HA) AdvancedComfort Low-E IG PEL-N-150-00700-00001 3 5 air 0.27 0.26 0.47 41 20 with grilles-between-the-glass PEL-N-150-00702-00001 0.28 0.24 0.43 41 18
11/16" (HA) NaturalSun Low-E IG PEL-N-150-00662-00001 3 5 air 0.33 0.48 0.55 52 26 with grilles-between-the-glass PEL-N-150-00664-00001 0.34 0.44 0.50 52
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-8
CASEMENT
GLAZING PERFORMANCE - TOTAL UNIT
Vent Units
Tinted Glass
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
VENT – WITH TINTED GLAZING N NC SC S 1 2 311/16" Bronze Advanced Low-E IG PEL-N-150-00641-00001 5 3 argon 0.29 0.23 0.32 58
with grilles-between-the-glass PEL-N-150-00642-00001 0.30 0.21 0.29 58
11/16" Gray Advanced Low-E IG PEL-N-150-00643-00001 5 3 argon 0.29 0.22 0.27 58 with grilles-between-the-glass PEL-N-150-00644-00001 0.30 0.20 0.25 58
11/16" Green Advanced Low-E IG PEL-N-150-00645-00001 5 3 argon 0.29 0.27 0.43 58 with grilles-between-the-glass PEL-N-150-00646-00001 0.30 0.24 0.39 58
VENT — WITH FOAM INSULATION AND TINTED GLAZING11/16" Bronze Advanced Low-E IG PEL-N-150-00715-00001 5 3 argon 0.27 0.27 0.36 58 17
with grilles-between-the-glass PEL-N-150-00716-00001 0.28 0.24 0.32 58
11/16" Gray Advanced Low-E IG PEL-N-150-00717-00001 5 3 argon 0.27 0.25 0.31 58 17 with grilles-between-the-glass PEL-N-150-00718-00001 0.28 0.22 0.28 58
11/16" Green Advanced Low-E IG PEL-N-150-00719-00001 5 3 argon 0.27 0.30 0.49 58 20 with grilles-between-the-glass PEL-N-150-00720-00001 0.28 0.27 0.44 58 17
HIGH ALTITUDE GLAZING – WITH TINTED GLAZING11/16" Bronze Advanced Low-E IG PEL-N-150-00635-00001 5 3 air 0.33 0.24 0.32 54
with grilles-between-the-glass PEL-N-150-00636-00001 0.34 0.22 0.29 54
11/16" Gray Advanced Low-E IG PEL-N-150-00637-00001 5 3 air 0.33 0.22 0.27 54 with grilles-between-the-glass PEL-N-150-00638-00001 0.34 0.20 0.25 54
11/16" Green Advanced Low-E IG PEL-N-150-00639-00001 5 3 air 0.33 0.27 0.43 54 with grilles-between-the-glass PEL-N-150-00640-00001 0.34 0.25 0.39 54
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION AND TINTED GLAZING11/16" Bronze Advanced Low-E IG PEL-N-150-00709-00001 5 3 air 0.32 0.24 0.32 55
with grilles-between-the-glass PEL-N-150-00710-00001 0.33 0.22 0.29 55
11/16" Gray Advanced Low-E IG PEL-N-150-00711-00001 5 3 air 0.32 0.22 0.27 55 with grilles-between-the-glass PEL-N-150-00712-00001 0.33 0.20 0.25 55
11/16" Green Advanced Low-E IG PEL-N-150-00713-00001 5 3 air 0.32 0.27 0.43 55 with grilles-between-the-glass PEL-N-150-00714-00001 0.33 0.25 0.39 55
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-9
CASEMENT
GLAZING PERFORMANCE - TOTAL UNIT
Vent Units
Laminated Glass
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
VENT — WITH LAMINATED GLAZING N NC SC S 1 2 311/16" Advanced Low-E IG PEL-N-150-00606-00001 3 6 argon 0.31 0.26 0.48 56
with grilles-between-the-glass PEL-N-150-00609-00001 0.32 0.24 0.43 56
11/16" SunDefense™ IG PEL-N-150-00620-00001 3 6 argon 0.30 0.20 0.44 56 with grilles-between-the-glass PEL-N-150-00623-00001 0.32 0.18 0.40 57
VENT — WITH FOAM INSULATION AND LAMINATED GLAZING11/16" Advanced Low-E IG PEL-N-150-00680-00001 3 6 argon 0.30 0.26 0.48 56
with grilles-between-the-glass PEL-N-150-00683-00001 0.31 0.24 0.43 56
11/16" SunDefense™ IG PEL-N-150-00694-00001 3 6 argon 0.29 0.20 0.44 57 with grilles-between-the-glass PEL-N-150-00697-00001 0.31 0.18 0.40 57
HIGH ALTITUDE GLAZING – WITH LAMINATED GLAZING11/16" Advanced Low-E IG PEL-N-150-00599-00001 3 6 air 0.35 0.27 0.48 52
with grilles-between-the-glass PEL-N-150-00602-00001 0.37 0.24 0.43 52
11/16" SunDefense IG PEL-N-150-00613-00001 3 6 air 0.35 0.20 0.44 52 with grilles-between-the-glass PEL-N-150-00616-00001 0.36 0.19 0.40 52
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION AND LAMINATED GLAZING11/16" Advanced Low-E IG PEL-N-150-00673-00001 3 6 air 0.34 0.27 0.48 52
with grilles-between-the-glass PEL-N-150-00676-00001 0.36 0.24 0.43 52
11/16" SunDefense IG PEL-N-150-00687-00001 3 6 air 0.34 0.20 0.44 52 with grilles-between-the-glass PEL-N-150-00690-00001 0.35 0.19 0.40 52
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-10
CASEMENT
GLAZING PERFORMANCE – TOTAL UNIT
Fixed Units
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
FIXED UNITS N NC SC S 1 2 311/16" Clear IG PEL-N-152-01133-00001 2.5 2.5 air 0.45 0.62 0.66 44
with grilles-between-the-glass PEL-N-152-01133-00002 0.45 0.56 0.59 4411/16" Clear IG PEL-N-152-01133-00003 3 3 air 0.45 0.62 0.66 44
with grilles-between-the-glass PEL-N-152-01133-00004 0.45 0.56 0.59 4411/16" Clear IG PEL-N-152-01138-00001 5 5 air 0.47 0.60 0.65 41
with grilles-between-the-glass PEL-N-152-01143-00001 0.48 0.53 0.58 4111/16" Advanced Low-E IG PEL-N-152-01180-00001 2.5 2.5 argon 0.27 0.30 0.56 59 23
with grilles-between-the-glass PEL-N-152-01180-00002 0.27 0.27 0.50 59 2111/16" Advanced Low-E IG PEL-N-152-01180-00003 3 3 argon 0.27 0.30 0.56 59 23
with grilles-between-the-glass PEL-N-152-01180-00004 0.27 0.27 0.50 59 2111/16" Advanced Low-E IG PEL-N-152-01185-00001 5 5 argon 0.30 0.30 0.55 55
with grilles-between-the-glass PEL-N-152-01190-00001 0.32 0.27 0.49 5511/16" SunDefense™ IG PEL-N-152-01202-00001 2.5 2.5 argon 0.27 0.22 0.52 60 18
with grilles-between-the-glass PEL-N-152-01202-00002 0.27 0.20 0.46 60 1711/16" SunDefense™ IG PEL-N-152-01202-00003 3 3 argon 0.27 0.22 0.52 60 18
with grilles-between-the-glass PEL-N-152-01202-00004 0.27 0.20 0.46 60 1711/16" SunDefense™ IG PEL-N-152-01207-00001 5 5 argon 0.29 0.23 0.51 55
with grilles-between-the-glass PEL-N-152-01212-00001 0.31 0.21 0.46 5511/16" AdvancedComfort Low-E IG PEL-N-152-01220-00001 2.5 2.5 argon 0.23 0.30 0.55 47 28
with grilles-between-the-glass PEL-N-152-01220-00002 0.23 0.27 0.49 47 2611/16" AdvancedComfort Low-E IG PEL-N-152-01220-00003 3 3 argon 0.23 0.30 0.55 47 28
with grilles-between-the-glass PEL-N-152-01220-00004 0.23 0.27 0.49 47 2611/16" AdvancedComfort Low-E IG PEL-N-152-01223-00001 5 5 argon 0.26 0.29 0.54 42 23
with grilles-between-the-glass PEL-N-152-01226-00001 0.27 0.26 0.48 42 2011/16" NaturalSun Low-E IG PEL-N-152-01162-00001 2.5 2.5 argon 0.28 0.55 0.64 59 36
with grilles-between-the-glass PEL-N-152-01162-00002 0.28 0.50 0.57 59 3311/16" NaturalSun Low-E IG PEL-N-152-01162-00003 3 3 argon 0.28 0.55 0.64 59 36
with grilles-between-the-glass PEL-N-152-01162-00004 0.28 0.50 0.57 59 3311/16" NaturalSun Low-E IG PEL-N-152-01165-00001 5 5 argon 0.31 0.53 0.63 54 31
with grilles-between-the-glass PEL-N-152-01168-00001 0.32 0.48 0.56 54 27FIXED UNITS — WITH FOAM INSULATION11/16" Advanced Low-E IG PEL-N-152-01298-00001 2.5 2.5 argon 0.26 0.30 0.56 59 24
with grilles-between-the-glass PEL-N-152-01298-00002 0.26 0.27 0.50 59 2211/16" Advanced Low-E IG PEL-N-152-01298-00003 3 3 argon 0.26 0.30 0.56 59 24
with grilles-between-the-glass PEL-N-152-01298-00004 0.26 0.27 0.50 59 2211/16" Advanced Low-E IG PEL-N-152-01303-00001 5 5 argon 0.29 0.30 0.55 55
with grilles-between-the-glass PEL-N-152-01308-00001 0.31 0.27 0.49 5511/16" SunDefense IG PEL-N-152-01320-00001 2.5 2.5 argon 0.26 0.22 0.52 60 19
with grilles-between-the-glass PEL-N-152-01320-00002 0.26 0.20 0.46 60 1811/16" SunDefense IG PEL-N-152-01320-00003 3 3 argon 0.26 0.22 0.52 60 19
with grilles-between-the-glass PEL-N-152-01320-00004 0.26 0.20 0.46 60 1811/16" SunDefense IG PEL-N-152-01325-00001 5 5 argon 0.29 0.23 0.51 55
with grilles-between-the-glass PEL-N-152-01330-00001 0.30 0.21 0.46 5511/16" AdvancedComfort Low-E IG PEL-N-152-01338-00001 2.5 2.5 argon 0.22 0.30 0.55 47 29
with grilles-between-the-glass PEL-N-152-01338-00002 0.22 0.27 0.49 47 2711/16" AdvancedComfort Low-E IG PEL-N-152-01338-00003 3 3 argon 0.22 0.30 0.55 47 29
with grilles-between-the-glass PEL-N-152-01338-00004 0.22 0.27 0.49 47 2711/16" AdvancedComfort Low-E IG PEL-N-152-01341-00001 5 5 argon 0.25 0.29 0.54 42 25
with grilles-between-the-glass PEL-N-152-01344-00001 0.26 0.26 0.48 42 2211/16" NaturalSun Low-E IG PEL-N-152-01280-00001 2.5 2.5 argon 0.27 0.55 0.64 59 37
with grilles-between-the-glass PEL-N-152-01280-00002 0.27 0.50 0.57 59 3411/16" NaturalSun Low-E IG PEL-N-152-01280-00003 3 3 argon 0.27 0.55 0.64 59 37
with grilles-between-the-glass PEL-N-152-01280-00004 0.27 0.50 0.57 59 3411/16" NaturalSun Low-E IG PEL-N-152-01283-00001 5 5 argon 0.30 0.53 0.63 54 32
with grilles-between-the-glass PEL-N-152-01286-00001 0.32 0.48 0.56 54 27
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Rev. 05/09/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-11
CASEMENT
GLAZING PERFORMANCE – TOTAL UNIT
Fixed Units — High Altitude
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient
VLT % = Visible Light Transmission CR = Condensation Resistance
ER = Canadian Energy Rating Climate Zones
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
HIGH ALTITUDE GLAZING N NC SC S 1 2 311/16" (HA) Advanced Low-E IG PEL-N-152-01169-00001 2.5 2.5 air 0.31 0.30 0.56 55
with grilles-between-the-glass PEL-N-152-01169-00002 0.31 0.28 0.50 55
11/16" (HA) Advanced Low-E IG PEL-N-152-01169-00003 3 3 air 0.31 0.30 0.56 55 with grilles-between-the-glass PEL-N-152-01169-00004 0.31 0.28 0.50 55
11/16" (HA) Advanced Low-E IG PEL-N-152-01174-00001 5 5 air 0.35 0.30 0.55 50 with grilles-between-the-glass PEL-N-152-01179-00001 0.37 0.27 0.49 50
11/16" (HA) SunDefense IG PEL-N-152-01191-00001 2.5 2.5 air 0.31 0.23 0.52 56 with grilles-between-the-glass PEL-N-152-01191-00002 0.31 0.21 0.46 56
11/16" (HA) SunDefense IG PEL-N-152-01191-00003 3 3 air 0.31 0.23 0.52 56 with grilles-between-the-glass PEL-N-152-01191-00004 0.31 0.21 0.46 56
11/16" (HA) SunDefense IG PEL-N-152-01196-00001 5 5 air 0.35 0.23 0.51 51 with grilles-between-the-glass PEL-N-152-01201-00001 0.36 0.21 0.46 51
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01213-00001 2.5 2.5 air 0.26 0.30 0.55 43 24 with grilles-between-the-glass PEL-N-152-01213-00002 0.26 0.27 0.49 43 22
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01213-00003 3 3 air 0.26 0.30 0.55 43 24 with grilles-between-the-glass PEL-N-152-01213-00004 0.26 0.27 0.49 43 22
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01216-00001 5 5 air 0.29 0.29 0.54 38 with grilles-between-the-glass PEL-N-152-01219-00001 0.30 0.26 0.48 38
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01155-00001 2.5 2.5 air 0.32 0.55 0.64 55 31 with grilles-between-the-glass PEL-N-152-01155-00002 0.32 0.50 0.57 55 28
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01155-00003 3 3 air 0.32 0.55 0.64 55 31 with grilles-between-the-glass PEL-N-152-01155-00004 0.32 0.50 0.57 55 28
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01158-00001 5 5 air 0.36 0.53 0.63 50 25 with grilles-between-the-glass PEL-N-152-01161-00001 0.38 0.48 0.56 50
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION11/16" (HA) Advanced Low-E IG PEL-N-152-01287-00001 2.5 2.5 air 0.30 0.30 0.56 56
with grilles-between-the-glass PEL-N-152-01287-00002 0.30 0.28 0.50 56
11/16" (HA) Advanced Low-E IG PEL-N-152-01287-00003 3 3 air 0.30 0.30 0.56 56 with grilles-between-the-glass PEL-N-152-01287-00004 0.30 0.28 0.50 56
11/16" (HA) Advanced Low-E IG PEL-N-152-01292-00001 5 5 air 0.34 0.30 0.55 50 with grilles-between-the-glass PEL-N-152-01297-00001 0.36 0.27 0.49 50
11/16" (HA) SunDefense IG PEL-N-152-01309-00001 2.5 2.5 air 0.30 0.23 0.52 56 with grilles-between-the-glass PEL-N-152-01309-00002 0.30 0.21 0.46 56
11/16" (HA) SunDefense IG PEL-N-152-01309-00003 3 3 air 0.30 0.23 0.52 56 with grilles-between-the-glass PEL-N-152-01309-00004 0.30 0.21 0.46 56
11/16" (HA) SunDefense IG PEL-N-152-01314-00001 5 5 air 0.34 0.23 0.51 51 with grilles-between-the-glass PEL-N-152-01319-00001 0.36 0.21 0.46 51
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01331-00001 2.5 2.5 air 0.25 0.30 0.55 43 25 with grilles-between-the-glass PEL-N-152-01331-00002 0.25 0.27 0.49 43 23
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01331-00003 3 3 air 0.25 0.30 0.55 43 25 with grilles-between-the-glass PEL-N-152-01331-00004 0.25 0.27 0.49 43 23
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01334-00001 5 5 air 0.28 0.29 0.54 38 21 with grilles-between-the-glass PEL-N-152-01337-00001 0.30 0.26 0.48 38
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01273-00001 2.5 2.5 air 0.31 0.55 0.64 55 32 with grilles-between-the-glass PEL-N-152-01273-00002 0.31 0.50 0.57 55 29
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01273-00003 3 3 air 0.31 0.55 0.64 55 32 with grilles-between-the-glass PEL-N-152-01273-00004 0.31 0.50 0.57 55 29
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01276-00001 5 5 air 0.35 0.53 0.63 50 26 with grilles-between-the-glass PEL-N-152-01279-00001 0.37 0.48 0.56 50
Rev. 05/09/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-12
CASEMENT
GLAZING PERFORMANCE - TOTAL UNIT
Fixed Units
3mm / 5mm Glass
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
FIXED N NC SC S 1 2 311/16" Clear IG PEL-N-152-01134-00001 3 5 air 0.46 0.62 0.66 42
with grilles-between-the-glass PEL-N-152-01139-00001 0.47 0.56 0.59 42
11/16" Advanced Low-E IG PEL-N-152-01181-00001 3 5 argon 0.28 0.30 0.56 56 21 with grilles-between-the-glass PEL-N-152-01186-00001 0.29 0.27 0.50 56
11/16" SunDefense™ IG PEL-N-152-01203-00001 3 5 argon 0.27 0.23 0.52 57 19 with grilles-between-the-glass PEL-N-152-01208-00001 0.29 0.21 0.46 57
11/16" AdvancedComfort Low-E IG PEL-N-152-01221-00001 3 5 argon 0.24 0.29 0.55 44 26 with grilles-between-the-glass PEL-N-152-01224-00001 0.25 0.27 0.49 44 23
11/16" NaturalSun Low-E IG PEL-N-152-01163-00001 3 5 argon 0.29 0.55 0.63 56 35 with grilles-between-the-glass PEL-N-152-01166-00001 0.30 0.50 0.56 56 31
FIXED — WITH FOAM INSULATION11/16" Advanced Low-E IG PEL-N-152-01299-00001 3 5 argon 0.27 0.30 0.56 57 23
with grilles-between-the-glass PEL-N-152-01304-00001 0.28 0.27 0.50 57 2011/16" SunDefense IG PEL-N-152-01321-00001 3 5 argon 0.27 0.23 0.52 57 19
with grilles-between-the-glass PEL-N-152-01326-00001 0.28 0.21 0.46 57 1611/16" AdvancedComfort Low-E IG PEL-N-152-01339-00001 3 5 argon 0.23 0.29 0.55 44 27
with grilles-between-the-glass PEL-N-152-01342-00001 0.24 0.27 0.49 44 2511/16" NaturalSun Low-E IG PEL-N-152-01281-00001 3 5 argon 0.28 0.55 0.63 56 36
with grilles-between-the-glass PEL-N-152-01284-00001 0.29 0.50 0.56 56 32HIGH ALTITUDE GLAZING
11/16" (HA) Advanced Low-E IG PEL-N-152-01170-00001 3 5 air 0.33 0.30 0.56 52 with grilles-between-the-glass PEL-N-152-01175-00001 0.34 0.28 0.50 52
11/16" (HA) SunDefense IG PEL-N-152-01192-00001 3 5 air 0.32 0.23 0.52 53 with grilles-between-the-glass PEL-N-152-01197-00001 0.34 0.21 0.46 53
11/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01214-00001 3 5 air 0.27 0.29 0.55 40 22 with grilles-between-the-glass PEL-N-152-01217-00001 0.28 0.27 0.49 40 20
11/16" (HA) NaturalSun Low-E IG PEL-N-152-01156-00001 3 5 air 0.33 0.55 0.63 52 30 with grilles-between-the-glass PEL-N-152-01159-00001 0.35 0.49 0.56 52
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION11/16" (HA) Advanced Low-E IG PEL-N-152-01288-00001 3 5 air 0.32 0.30 0.56 53
with grilles-between-the-glass PEL-N-152-01293-00001 0.33 0.28 0.50 5311/16" (HA) SunDefense IG PEL-N-152-01310-00001 3 5 air 0.31 0.23 0.52 53
with grilles-between-the-glass PEL-N-152-01315-00001 0.33 0.21 0.46 5311/16" (HA) AdvancedComfort Low-E IG PEL-N-152-01332-00001 3 5 air 0.26 0.29 0.55 40 23
with grilles-between-the-glass PEL-N-152-01335-00001 0.27 0.27 0.49 40 2111/16" (HA) NaturalSun Low-E IG PEL-N-152-01274-00001 3 5 air 0.33 0.55 0.63 52 30
with grilles-between-the-glass PEL-N-152-01277-00001 0.34 0.49 0.56 52 25
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-13
CASEMENT
GLAZING PERFORMANCE - TOTAL UNIT
Fixed Units
Tinted Glass
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
FIXED – WITH TINTED GLAZING N NC SC S 1 2 311/16" Bronze Advanced Low-E IG PEL-N-152-01239-00001 5 3 argon 0.28 0.27 0.36 58 20
with grilles-between-the-glass PEL-N-152-01240-00001 0.29 0.24 0.32 58
11/16" Gray Advanced Low-E IG PEL-N-152-01243-00001 5 3 argon 0.28 0.25 0.31 58 19 with grilles-between-the-glass PEL-N-152-01244-00001 0.29 0.22 0.28 58
11/16" Green Advanced Low-E IG PEL-N-152-01247-00001 5 3 argon 0.28 0.30 0.49 58 21 with grilles-between-the-glass PEL-N-152-01248-00001 0.29 0.27 0.44 58
FIXED — WITH FOAM INSULATION AND TINTED GLAZING11/16" Bronze Advanced Low-E IG PEL-N-152-01357-00001 5 3 argon 0.27 0.27 0.36 58 21
with grilles-between-the-glass PEL-N-152-01358-00001 0.28 0.24 0.32 58 1811/16" Gray Advanced Low-E IG PEL-N-152-01361-00001 5 3 argon 0.27 0.25 0.31 58 20
with grilles-between-the-glass PEL-N-152-01362-00001 0.28 0.22 0.28 58 1711/16" Green Advanced Low-E IG PEL-N-152-01365-00001 5 3 argon 0.27 0.30 0.49 58 23
with grilles-between-the-glass PEL-N-152-01366-00001 0.28 0.27 0.44 58 20HIGH ALTITUDE GLAZING – WITH TINTED GLAZING
11/16" Bronze Advanced Low-E IG PEL-N-152-01227-00001 5 3 air 0.32 0.27 0.36 54 with grilles-between-the-glass PEL-N-152-01228-00001 0.34 0.24 0.32 54
11/16" Gray Advanced Low-E IG PEL-N-152-01231-00001 5 3 air 0.32 0.25 0.31 54 with grilles-between-the-glass PEL-N-152-01232-00001 0.34 0.23 0.28 54
11/16" Green Advanced Low-E IG PEL-N-152-01235-00001 5 3 air 0.32 0.31 0.49 54 with grilles-between-the-glass PEL-N-152-01236-00001 0.34 0.28 0.44 54
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION AND TINTED GLAZING11/16" Bronze Advanced Low-E IG PEL-N-152-01345-00001 5 3 air 0.32 0.27 0.36 54
with grilles-between-the-glass PEL-N-152-01346-00001 0.33 0.24 0.32 5411/16" Gray Advanced Low-E IG PEL-N-152-01349-00001 5 3 air 0.32 0.25 0.31 54
with grilles-between-the-glass PEL-N-152-01350-00001 0.33 0.23 0.28 5411/16" Green Advanced Low-E IG PEL-N-152-01353-00001 5 3 air 0.32 0.31 0.49 54
with grilles-between-the-glass PEL-N-152-01354-00001 0.33 0.28 0.44 54
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-14
CASEMENT
GLAZING PERFORMANCE - TOTAL UNIT
Fixed Units
Laminated Glass
Gla
zing
Th
ickn
ess
Type of Glazing NFRC Certified Product #
Glass (mm)
Gap Fill
Performance Values 1
Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext. Int.
U-F
acto
r
SHG
C
VLT
CR
U. S. Canada 2
Zone ER Zone
FIXED — WITH LAMINATED GLAZING N NC SC S 1 2 311/16" Advanced Low-E IG PEL-N-152-01182-00001 3 6 argon 0.30 0.30 0.55 56
with grilles-between-the-glass PEL-N-152-01187-00001 0.32 0.27 0.49 56
11/16" Advanced Low-E IG PEL-N-152-01184-00001 4 7 argon 0.33 0.30 0.55 53 with grilles-between-the-glass PEL-N-152-01189-00001 0.35 0.27 0.49 53
11/16" SunDefense™ IG PEL-N-152-01204-00001 3 6 argon 0.29 0.23 0.51 56 with grilles-between-the-glass PEL-N-152-01209-00001 0.31 0.20 0.45 56
11/16" SunDefense™ IG PEL-N-152-01206-00001 4 7 argon 0.32 0.23 0.51 53 with grilles-between-the-glass PEL-N-152-01211-00001 0.35 0.21 0.46 53
FIXED — WITH FOAM INSULATION AND LAMINATED GLAZING11/16" Advanced Low-E IG PEL-N-152-01300-00001 3 6 argon 0.29 0.30 0.55 56
with grilles-between-the-glass PEL-N-152-01305-00001 0.31 0.27 0.49 56
11/16" Advanced Low-E IG PEL-N-152-01302-00001 4 7 argon 0.32 0.30 0.55 53 with grilles-between-the-glass PEL-N-152-01307-00001 0.35 0.27 0.49 53
11/16" SunDefense™ IG PEL-N-152-01322-00001 3 6 argon 0.29 0.23 0.51 56 with grilles-between-the-glass PEL-N-152-01327-00001 0.30 0.20 0.45 56
11/16" SunDefense™ IG PEL-N-152-01324-00001 4 7 argon 0.32 0.23 0.51 53 with grilles-between-the-glass PEL-N-152-01329-00001 0.34 0.21 0.46 53
HIGH ALTITUDE GLAZING – WITH LAMINATED GLAZING11/16" Advanced Low-E IG PEL-N-152-01171-00001 3 6 air 0.35 0.30 0.55 51
with grilles-between-the-glass PEL-N-152-01176-00001 0.37 0.27 0.49 51
11/16" Advanced Low-E IG PEL-N-152-01173-00001 4 7 air 0.38 0.30 0.55 48 with grilles-between-the-glass PEL-N-152-01178-00001 0.41 0.27 0.49 48
11/16" SunDefense IG PEL-N-152-01193-00001 3 6 air 0.35 0.23 0.51 51 with grilles-between-the-glass PEL-N-152-01198-00001 0.37 0.21 0.45 51
11/16" SunDefense IG PEL-N-152-01195-00001 4 7 air 0.38 0.24 0.51 48 with grilles-between-the-glass PEL-N-152-01200-00001 0.41 0.21 0.46 48
HIGH ALTITUDE GLAZING — WITH FOAM INSULATION AND LAMINATED GLAZING11/16" Advanced Low-E IG PEL-N-152-01289-00001 3 6 air 0.34 0.30 0.55 51
with grilles-between-the-glass PEL-N-152-01294-00001 0.36 0.27 0.49 51
11/16" Advanced Low-E IG PEL-N-152-01291-00001 4 7 air 0.37 0.30 0.55 48 with grilles-between-the-glass PEL-N-152-01296-00001 0.40 0.27 0.49 48
11/16" SunDefense IG PEL-N-152-01311-00001 3 6 air 0.34 0.23 0.51 52 with grilles-between-the-glass PEL-N-152-01316-00001 0.36 0.21 0.45 52
11/16" SunDefense IG PEL-N-152-01313-00001 4 7 air 0.37 0.24 0.51 49 with grilles-between-the-glass PEL-N-152-01318-00001 0.40 0.21 0.46 49
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500.
ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
For center-glass values, see the Product Performance section.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating
Climate Zones
Rev. 06/27/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-15
CASEMENT
A combination is defined as an assembly formed by two or more separate windows or doors whose frames are mulled together utilizing a combination mullion or reinforcing mullion.
Below are available factory-assembled combinations. See the Combination section for requirements and limitations related to mulling various combinations plus configuration size range information.
2-WIDE 3-WIDE EQUAL 4-WIDE
3-WIDE UNEQUAL CENTER FIXED WITH FLANKERS TRANSOM OVER SINGLE UNIT
COMBINATION ASSEMBLIES
GRILLE TYPES
Grille Patterns
Traditional Custom - Equally Divided
Traditional Custom - Equally Divided
Traditional Custom - Equally Divided
Traditional Custom - Equally DividedTraditional 9-Lite
PrairieTop Row Custom
Equally Divided
Standard corner lite dimension for Prairie patterns = 4" visible glass (VG).
(1) Standard visible glass to center line of separator bar = 14" or half the total visible glass height, whichever is smaller. Multiple rows are available up to 50% glass size.
Pattern availability may vary depending on size of unit.
VG = Visible Glass
Lite dimensions noted can vary.
Grille Profiles
GRILLES-BETWEEN-THE-GLASS
3/4" Contour
3/4"
3/4" Contoured
Downloadable PDF file.
Click here for the Impervia Combinations Section
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-16
CASEMENT
Special Size Frame Dimensions*
MINIMUM MAXIMUM
VE
NT 1'5-1/2" W x 1'8" H
(445 x 508)3'1-1/2" W x 6'7-1/2" H
(953 x 2 019)
FIX
ED 1'1-1/2" W x 11-1/2" H
(343 x 292)5'11-1/2" W x 6'7-1/2" H
(1 816 x 2 019)
T = Tempered glass.
Not to scale.
Any vent casement with frame height greater than 70" will have 3mm tempered glass to reduce sash weight.
All units are available as fixed in the Casement section.
Traditional grille patterns shown. See Grilles in the Overview section for additional patterns and profiles.
* Available within size range shown.
Keep frame di men sions to the near est 1/8" increment. Frame width cannot exceed frame height on special size vent units.
1-6/6-0 2-0/6-0 3-0/6-02-8/6-02-6/6-02-4/6-0
1-6/5-6 2-0/5-6 3-0/5-62-8/5-62-6/5-62-4/5-6
1-6/2-6 2-0/2-6 2-4/2-6 2-6/2-6 2-8/2-6 3-0/2-6
1-6/5-0 2-0/5-0 2-8/5-0 3-0/5-02-6/5-02-4/5-0
1-6/3-0
1-6/3-6
1-6/4-0
2-0/3-0
2-0/3-6
2-0/4-0
2-4/4-6
2-4/4-0
2-4/3-6
2-4/3-0
2-6/4-6
2-6/4-0
2-6/3-6
2-6/3-0
2-8/4-6
2-8/4-0
2-8/3-6
2-8/3-0
3-0/4-6
3-0/4-0
3-0/3-6
3-0/3-0
2-0/4-61-6/4-6
1-6/1-2
1-6/1-6
1-6/2-0
2-0/1-2
2-0/1-6
2-0/2-0 2-4/2-0
2-4/1-6
2-4/1-2
2-6/2-0
2-6/1-6
2-6/1-2
2-8/2-0
2-8/1-6
2-8/1-2
3-0/2-0
3-0/1-6
3-0/1-2
Vent and Fixed Units
Transoms
"/ 21
"/ 21
"/ 21
1' 5
1' 1
1' 1
1"
/ 21"
/ 21"
/ 21"
/ 21"
/ 21"
/ 21"
/ 21"
/ 21
"/ 21"/ 21"/ 21"/ 21"/ 21"/ 21
TTTTT T
2' 6
"2'
5(762
)(7
49)
6' 0
"5'
11
(1 8
29)
(1 8
16)
5' 6
"5'
5
(1 6
76)
(1 6
64)
4' 1
1
(1 5
24)
(1 5
11)
5' 0
"
FrameOpening
(1 3
59)
(1 3
72)
4' 5
4' 6
"(1
207
)(1
219
)
3' 1
14'
0"
3' 6
"3'
5
(1 0
67)
(1 0
54)
3' 0
"2'
11
(914
)(9
02)
(445
)(4
57)
1' 6
"1'
2"
(356
)(3
43)
(597
)(6
10)
2' 0
"
2' 6"2' 5
(762)(749)
2' 4"2' 3
(711)(699)
2' 0"1' 11
(610)(597)
1' 6"1' 5
(457)(445) (800)
(813)
2' 72' 8"
2' 113' 0"
(914)(902)
2E3E 1E
1E1E E
E E E
EEE
E E E
EEE
E E E
3E
2E
2E
2E
2E
2E
2E
SPEC
IAL
SIZE
S AV
AILA
BLE
SPEC
IAL S
HORT
ER AN
D TA
LLER
SIZE
S AVA
ILABL
E
SPECIAL NARROWER AND WIDER SIZES AVAILABLE
Egress Notes:Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional side pivot hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E3 = With optional side pivot hardware, window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
See Design Data pages in this section for clear opening dimensions.
SIZE TABLES
Transom and Vent Units
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-17
CASEMENT
SIZE TABLES
Transoms and Fixed Units
Not to scale.
Traditional grille patterns shown. See Grilles in the Overview section for additional patterns and profiles.
Special Size Frame Dimensions*
MINIMUM MAXIMUM
VENT1' 5-1/2" W x 1' 8" H
(445 x 508)3' 1-1/2" W x 6' 7-1/2" H
(953 x 2 019)
FIXED1' 1-1/2" W x 11-1/2" H
(343 x 292)5' 11-1/2" W x 6' 7-1/2" H
(1 816 x 2 019)
* Available within size range shown.
Keep frame di men sions to the near est 1/8" increment.
SPECIAL NARROWER AND WIDER SIZES AVAILABLE
SPEC
IAL
SIZE
S AV
AILA
BLE
SPEC
IAL
SHO
RTER
AN
D T
ALLE
R S
IZES
AVA
ILAB
LE
6-0/6-05-0/6-04-0/6-0
6-0/5-65-0/5-64-0/5-6
6-0/5-0
6-0/4-6
6-0/4-0
6-0/3-6
6-0/3-0
5-0/5-0
5-0/4-6
5-0/4-0
5-0/3-6
5-0/3-0
4-0/5-0
4-0/4-6
4-0/4-0
4-0/3-6
4-0/3-0
6-0/2-0
6-0/1-6
6-0/1-2
5-0/2-0
5-0/1-6
5-0/1-2
4-0/2-0
4-0/1-6
4-0/1-2
Fixed Units
Transoms
"/21"/21"/21
"/ 21
"/ 21
"/ 21
(445
)(4
57)
1' 5
1' 6
"1'
11'
2"
(356
)(3
43)
(597
)(6
10)
1' 1
12'
0"
"/ 21
"/ 21
"/ 21
"/ 21
"/ 21
"/ 21
"/ 21
6' 0
"5'
11
(1 8
29)
(1 8
16)
5' 6
"5'
5
(1 6
76)
(1 6
64)
4' 1
1
(1 5
24)
(1 5
11)
5' 0
"
(1 3
59)
(1 3
72)
4' 5
4' 6
"
(1 2
07)
(1 2
19)
3' 1
14'
0"
3' 6
"3'
5
(1 0
67)
(1 0
54)
3' 0
"2'
11
(914
)(9
02)
5' 116' 0"
(1 829)(1 816)
4' 115' 0"
(1 524)(1 511)
3' 114' 0"
(1 219)(1 207)
Frame
Opening
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-18
CASEMENT
DESIGN DATA
Vent Units
VENT UNITS
Unit
Eg
ress Clear Opening Vent
Area Ft2
Visible Glass
Ft2
Standard Glass Thickness (mm) Performance
Class & Grade1 Width (Inches)
Height (Inches) Ft2 Annealed Tempered
1-6/2-6 7-13/16 25-1/16 1.3 1.8 2.0 2.5 3 LC501-6/3-0 7-13/16 31-1/16 1.6 2.3 2.5 2.5 3 LC501-6/3-6 7-13/16 37-1/16 2.0 2.7 3.0 2.5 3 LC501-6/4-0 7-13/16 43-1/16 2.3 3.2 3.5 2.5 3 LC501-6/4-6 7-13/16 49-1/16 2.6 3.6 4.0 2.5 3 LC501-6/5-0 7-13/16 55-1/16 2.9 4.1 4.5 2.5 3 LC501-6/5-6 7-13/16 61-1/16 3.3 4.6 5.0 2.5 3 LC50
1-6/6-0 T 7-13/16 67-1/16 3.6 5.0 5.5 – 3 LC502-0/2-6 13-13/16 25-1/16 2.4 2.8 3.0 2.5 3 LC502-0/3-0 13-13/16 31-1/16 2.9 3.5 3.7 2.5 3 LC502-0/3-6 13-13/16 37-1/16 3.5 4.2 4.5 2.5 3 LC502-0/4-0 13-13/16 43-1/16 4.1 4.9 5.2 2.5 3 LC502-0/4-6 13-13/16 49-1/16 4.7 5.6 6.0 2.5 3 LC502-0/5-0 13-13/16 55-1/16 5.2 6.4 6.7 2.5 3 LC45/LC502-0/5-6 13-13/16 61-1/16 5.8 7.1 7.5 2.5 3 LC40/LC50
2-0/6-0 T 13-13/16 67-1/16 6.4 7.8 8.2 – 3 LC502-4/2-6 17-13/16 25-1/16 3.1 3.5 3.6 2.5 3 LC502-4/3-0 E3 23-3/8 31-1/16 5.0 4.4 4.6 2.5 3 LC502-4/3-6 E2 23-3/8 37-1/16 6.0 5.2 5.5 2.5 3 LC502-4/4-0 E2 23-3/8 43-1/16 7.0 6.1 6.4 2.5 3 LC502-4/4-6 E2 23-3/8 49-1/16 7.9 7.0 7.3 2.5 3 LC502-4/5-0 E2 23-3/8 55-1/16 8.9 7.8 8.2 2.5 3 LC45/LC502-4/5-6 E2 23-3/8 61-1/16 9.9 8.7 9.1 2.5 3 LC40/LC50
2-4/6-0 T E2 23-3/8 67-1/16 10.9 9.6 10.1 – 3 LC502-6/2-6 20-1/2 25-1/16 3.5 3.8 4.0 2.5 3 LC502-6/3-0 E3 25-3/8 31-1/16 3.5 4.8 5.0 2.5 3 LC502-6/3-6 E1 25-3/8 37-1/16 4.4 5.7 6.0 2.5 3 LC502-6/4-0 E 25-3/8 43-1/16 5.2 6.7 7.0 2.5 3 LC502-6/4-6 E 25-3/8 49-1/16 6.1 7.6 8.0 2.5 3 LC502-6/5-0 E 25-3/8 55-1/16 6.9 8.6 9.0 2.5 3 LC45/LC502-6/5-6 E 25-3/8 61-1/16 9.0 9.6 10.0 2.5 3 LC40/LC50
2-6/6-0 T E 25-3/8 67-1/16 11.8 10.5 11.0 3 3 LC502-8/2-6 21-13/16 25-1/16 3.8 4.1 4.3 2.5 3 LC502-8/3-0 E2 27-3/8 31-1/16 5.9 5.2 5.4 2.5 3 LC502-8/3-6 E1 27-3/8 37-1/16 7.0 6.2 6.5 2.5 3 LC502-8/4-0 E 27-3/8 43-1/16 8.1 7.3 7.6 2.5 3 LC502-8/4-6 E 27-3/8 49-1/16 9.3 8.3 8.6 2.5 3 LC502-8/5-0 E 27-3/8 55-1/16 10.4 9.3 9.7 2.5 3 LC502-8/5-6 E 27-3/8 61-1/16 11.6 10.4 10.8 3 3 LC50
2-8/6-0 T E 27-3/8 67-1/16 12.7 11.4 11.9 – 3 LC503-0/2-6 25-13/16 25-1/16 4.4 4.8 5.0 2.5 3 LC503-0/3-0 E1 25-13/16 31-1/16 5.5 6.0 6.2 2.5 3 LC503-0/3-6 E 25-13/16 37-1/16 6.6 7.2 7.5 2.5 3 LC503-0/4-0 E 25-13/16 43-1/16 7.7 8.4 8.7 2.5 3 LC503-0/4-6 E 25-13/16 49-1/16 8.7 9.6 10.0 2.5 3 LC45/LC503-0/5-0 E 25-13/16 55-1/16 9.8 10.8 11.2 3 3 LC503-0/5-6 E 25-13/16 61-1/16 10.9 12.0 12.5 3 3 LC50
3-0/6-0 T E 25-13/16 67-1/16 12.0 13.3 13.7 – 3 LC50
(1) Maximum performance when glazed with the appropriate glass thickness. Second value, where shown, requires tempered glass.
T=Any vent casement with frame height greater than 70" will have 3mm tempered glass to reduce sash weight.
To convert areas to square meters (m²), multiply square feet by 0.0929.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional side pivot hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E3 = With optional side pivot hardware, window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
CLEAR OPENING HEIGHT
Frame Height − 4-7/16"
CLEAR OPENING WIDTH
Hinge Frame Width Formula
Standard 29" to 29-1/2" FW − 9"
Standard >29-1/2" to 37-1/2" FW − 9-11/16"
Side Pivot ≥ 25" to ≤ 32" FW − 4-1/8"
VENT OPENING AREA
(FW − 6.518) × (FH − 5.641) ÷ 144
Rev. 04/23/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-19
CASEMENT
Miscellaneous Formulas
VISIBLE GLASS
Width = Frame – 5-7/16" Height = Frame – 5-7/16"
ACTUAL GLASS
Width = Frame – 4-3/8" Height = Frame – 4-3/8"
DESIGN DATA
Transoms and Fixed Units
(1) Maximum performance when glazed with the appropriate glass thickness. Second value, where shown, requires tempered glass.
To convert areas to square meters (m²), multiply square feet by 0.0929.
TRANSOM UNITS
Unit Visible Glass Ft2
Standard Glass Thickness (mm) Performance
Class & Grade 1Annealed Tempered
1-6/1-2 0.6 2.5 3 LC501-6/1-6 1.0 2.5 3 LC501-6/2-0 1.5 2.5 3 LC502-0/1-2 1.0 2.5 3 LC502-0/1-6 1.5 2.5 3 LC502-0/2-0 2.2 2.5 3 LC502-4/1-2 1.2 2.5 3 LC502-4/1-6 1.8 2.5 3 LC502-4/2-0 2.7 2.5 3 LC502-6/1-2 1.3 2.5 3 LC502-6/1-6 2.0 2.5 3 LC502-6/2-0 3.0 2.5 3 LC502-8/1-2 1.4 2.5 3 LC502-8/1-6 2.1 2.5 3 LC502-8/2-0 3.2 2.5 3 LC503-0/1-2 1.6 2.5 3 LC503-0/1-6 2.5 2.5 3 LC503-0/2-0 3.7 2.5 3 LC504-0/1-2 2.3 2.5 3 LC504-0/1-6 3.5 2.5 3 LC504-0/2-0 5.2 2.5 3 LC50
5-0/1-2 T 3.0 – 3 LC505-0/1-6 4.5 2.5 3 LC505-0/2-0 6.7 2.5 3 LC50
6-0/1-2 T 3.6 – 3 LC456-0/1-6 T 5.5 – 3 LC456-0/2-0 8.2 2.5 3 LC35/LC45
FIXED UNITS
Unit Visible Glass Ft2
Standard Glass Thickness (mm) Performance
Class & Grade 1Annealed Tempered
3-0/3-0 6.2 2.5 3 LC503-0/3-6 7.5 2.5 3 LC503-0/4-0 8.7 2.5 3 LC503-0/4-6 10.0 2.5 3 LC45/LC503-0/5-0 11.2 3 3 LC503-0/5-6 12.5 3 3 LC503-0/6-0 13.7 3 3 LC45/LC504-0/3-0 8.7 2.5 3 LC504-0/3-6 10.5 3 3 LC504-0/4-0 12.2 3 3 LC504-0/4-6 14.0 3 3 LC504-0/5-0 15.7 3 3 LC45/LC504-0/5-6 17.5 5 5 LC504-0/6-0 19.2 5 5 LC505-0/3-0 11.2 3 3 LC505-0/3-6 13.5 3 3 LC505-0/4-0 15.7 3 3 LC45/LC505-0/4-6 18.0 5 5 LC505-0/5-0 20.2 5 5 LC505-0/5-6 22.5 5 5 LC505-0/6-0 24.7 5 5 LC506-0/3-0 13.7 3 3 LC456-0/3-6 16.5 3 3 LC456-0/4-0 19.2 5 5 LC456-0/4-6 22.0 5 5 LC456-0/5-0 24.7 5 5 LC456-0/5-6 27.5 5 5 LC456-0/6-0 30.2 5 5 LC45
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-20
CASEMENT
DETAILED PRODUCT DESCRIPTIONS
FRAME
• Frame is Duracast—five-layer pultruded fiberglass material [with optional foam insulation1] reinforced with a Pella patented interlocking mat.
• Overall frame depth is 3-1/4". • Nominal wall thickness of Duracast® fiberglass composite members
is .050" to .070" thick.• Frame corners are mitered, joined and bonded with corner lock and
injected with polyurethane adhesive. • Jambs contain factory-drilled installation screw holes on block frame.
SASH
• Sash is Duracast fiberglass composite — five-layer pultruded fiberglass material, reinforced with a Pella patented interlocking mat.
• All sash members have mitered corners bonded with corner lock and sealed with injected polyurethane adhesive.
EXTERIOR / INTERIOR
• Duracast fiberglass composite surfaces with powder-coat paint finish. � Color is [White] [Tan] [Brown] [Black] [Morning Sky Gray].
- or - � Dual-color option [Tan] [Brown] [Black] [Morning Sky Gray]
exterior with White interior 2.
GLAZING SYSTEM
• Quality float glass complying with ASTM C 1036. � 11/16" insulating glass [[annealed] [tempered]] [obscure 3] [clear]
[[Advanced] [SunDefense™] [AdvancedComfort] [NaturalSun] Low-E coated, [with argon]]] [[bronze] [gray] [green] Advanced Low-E [with Argon]] sealed and bonded to sash.
• High altitude glazing available.
WEATHERSTRIPPING
Dual Weatherstripping• Continuous, flexible ThermoPlastic Vulcanizate material in dual
durometer design, compressed between frame and sash for positive seal on all four sides.
• Secondary ThermoPlastic Vulcanizate leaf-type weatherstrip between edge of sash and frame.
HARDWARE
• Roto operator assembly � Steel worm gear sash operator with hardened gears. � Operator base is zinc die cast with painted finish. � Operator linkage, hinge slide, and hinge arms are 300 series
stainless steel. � Exposed fasteners are stainless steel. � Hardware shall exceed 1,000 hours salt spray exposure per
ASTM B 117. • Finish of integrated folding crank is [baked enamel [White] [Brown]
[Tan] [Matte Black] [Morning Sky Gray]] [Bright Brass] [Satin Nickel] [Oil-Rubbed Bronze]. All vent units are available with left- or right-hand hinging.
• SureLock® System—A single handle locking system operates positive-acting arms that reach out and pull the sash into a locked position: one installed on units 27-1/2" and smaller frame height, two unison operating locks installed on units over 27-1/2" frame height.
• Lock handle finish is [baked enamel [White] [Brown] [Tan] [Matte Black] [Morning Sky Gray]] [Bright Brass] [Satin Nickel] [Oil-Rubbed Bronze].
OPTIONAL PRODUCTS
Screens• Conventional Black Vinyl-coated 18/16 mesh fiberglass screen cloth
complying with ASTM D 3656 and SMA 1201, set in aluminum frame fitted to inside of window, supplied complete with all necessary hardware.
• InView™ screens � Vinyl-coated 18/18 mesh fiberglass screen cloth complying with
SMA 1201, set in aluminum frame fitted to inside of window, supplied complete with all necessary hardware.
� Screen frame finish is baked enamel, color to match interior.Grilles• Grilles-Between-the-Glass
� Insulating glass contains 3/4" contoured aluminum grilles permanently installed between two panes of glass.
� Grilles are factory prefinished [White] [Tan] [Brown] [Black] [Morning Sky Gray] to match interior and exterior finish.
Hardware• Optional factory applied limited opening hardware available for vent
units in stainless steel; nominal 3" opening.• Optional window opening control device available for field
installation. Device allows window to open less than 4" with normal operation, with a release mechanism that allows the sash to open completely. Complies with ASTM F2090-10.
Casement
LOCK JAMBLJ
SILLS
HEADH
FOAM INSULATION INSERTS 1
(1) Foam insulation inserts are not available with clear glazing.
(2) Dual-color finish is not available on products with integral nailing fin.
(3) Obscure glazing is not available when AdvancedComfort Low-E coated IG is specified.
Rev. 06/28/2018
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-21
CASEMENT
NAILING FININTEGRAL
[30]
1 3/
16"
[33]1 5/16"
[49]1 15/16"
[37]
1 7/
16"
[33]
1 5/
16"
[19]
3/4"
[29]1 1/8"
[52]
2 1/
16"
[30]
1 3/
16"
[60]2 3/8"
[23]7/8"
with OFF SET FINBLOCK FRAMESTANDARD
[37]
1 7/
16"
[33]
1 5/
16"
[19]
3/4"
[29]1 1/8"
[52]
2 1/
16"
[30]
1 3/
16"
[33]1 5/16"
[49]1 15/16"
[52]
2 1/
16"
with STANDARD FINBLOCK FRAMESTANDARD
[37]
1 7/
16"
[33]
1 5/
16"
[19]
3/4"
[29]1 1/8"
[52]
2 1/
16"
BLOCK FRAMESTANDARD
[37]
1 7/
16"
[33]
1 5/
16"
[19]
3/4"
[29]1 1/8"
[83]3 1/4"
Scale 3" = 1' 0"
All dimensions are approximate.
UNIT SECTIONS
Installation Types
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-22
CASEMENT
UNIT SECTIONS
Block Frame Vent
Scale 3" = 1' 0"
All dimensions are approximate.
See the Installation and Performance section on PellaADM.com for mullion applications and structural limitations.
TYPICAL JOINING MULLIONS
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.comF-CM-23
CASEMENT
UNIT SECTIONS
Block Frame Fixed
Scale 3" = 1' 0"
All dimensions are approximate.