Shred & Steam Sterilizers · (Healthcare) Red bags, sharps, other regulated medical waste. The...

4
Shred & Steam Sterilizers Safely Sterilize Regulated Medical Waste, Single-Use Disposables, Animal Bedding, Other Solid Infectious Waste Streams

Transcript of Shred & Steam Sterilizers · (Healthcare) Red bags, sharps, other regulated medical waste. The...

Page 1: Shred & Steam Sterilizers · (Healthcare) Red bags, sharps, other regulated medical waste. The rmwXstream ™ system is designed specifically for healthcare facilities, to treat regulated

Shred & Steam SterilizersSafely Sterilize Regulated Medical Waste, Single-Use Disposables, Animal Bedding, Other Solid Infectious Waste Streams

Page 2: Shred & Steam Sterilizers · (Healthcare) Red bags, sharps, other regulated medical waste. The rmwXstream ™ system is designed specifically for healthcare facilities, to treat regulated

Take Control of Your Regulated Waste. Reduce Costs, Liability and Environmental Impact.

The Xstream™ system is designed for on-site shredding and steam sterilization of regulated medical waste. The technology is approved in over 450 installations in 82 countries worldwide.

Onsite treatment significantly reduces your environmental and safety footprint. Waste volume is reduced by 80%, offsite transport of hazardous waste is eliminated, hazardous waste handling costs are reduced, and treated material is rendered as common municipal waste, appropriate for recycling and potential reuse. Cost savings ranges from 30% to 50% over hazardous haul-away services. Avoidance of waste incineration also lowers overall energy use and carbon emissions.

No Chemicals, Smoke or Carbon

Emissions

Waste Volume Reduction

Treatment Cost Savings

Up to

Simple, Automated Operation, One

Day Training

Sterilization106

Over

Page 3: Shred & Steam Sterilizers · (Healthcare) Red bags, sharps, other regulated medical waste. The rmwXstream ™ system is designed specifically for healthcare facilities, to treat regulated

(Healthcare) Red bags, sharps, other regulated medical waste.The rmwXstream™ system is designed specifically for healthcare facilities, to treat regulated medical waste. Treating medical waste onsite improves safety in handling, reduces operational costs over service contracts, reduces waste volume by 80% and eliminates transportation of hazardous materials.

(BioPharm)Single-use bioreactor bags, tubing, sterile filters, roller bottles.Upgraded from RMW models, bioXstream™ is designed to protect the interests of biopharma companies. Enhancements include advanced sealing features, additional safeguards in every valve train, control automation upgrades and sterilization of condensate.

• Reduce CO2-heavy treatment services, such as incineration• Reduce waste transportation volume and costs• Treated material is rendered as common municipal waste• Reduces overall material volume by 80%

(Containment)Infectious animal bedding, carcasses and other high containment waste.Upgraded from BIO models, bslXstream™ is designed for the most demanding biosafety application requirements. PRI’s engineering expertise in high containment has been applied to this system, adding biosafety design features enabling users to treat solid infectious waste such as animal bedding, infected carcasses and BSL 3/4 lab waste.

• Designed with pressure-tight bioseal• Fully sealed system with status monitoring for all vessel penetrations• Temperature mapped using 12 points, to ensure setpoint is achieved• Integrated sterile vent filtration systems if requried• Multiple liquid discharge options

Available in Three Product Families:

InsideContainment

OutsideContainment

NO BSLRMW

BSL 1-2SINGLE-USE

BSL 1-4, AGBEDDING & CARCASSES

BIOSEAL

MODEL CAPACITY TIME ELECTRIC STEAM WATER

T-100 100 L (26 Gal) 30 min 1.4 kWh 6 kg (13 lbs) 5 L (1.3 Gal)

T-150 150 L (40 Gal) 30 min 1.4 kWh 9 kg (20 lbs) 15 L (4 Gal)

T-300 350 L (93 Gal) 30 min 1.7 kWh 15 kg (33 lbs) 25 L (7 Gal)

T-700 700 L (185 Gal) 30 min 3.5 kWh 18 kg (40 lbs) 30 L (8 Gal)

T-1000 1100 L (291 Gal) 35 min 4.0 kWh 20 kg (44 lbs) 35 L (9 Gal)

T-2000 2500 L (660 Gal) 45 min 9.0 kWh 40 kg (88 lbs) 50 L (13 Gal)

MODEL CAPACITY TIME ELECTRIC STEAM WATER

X-300 350 L (93 Gal) 30 min 1.7 kWh 15 kg (33 lbs) 25 L (7 Gal)

X-700 700 L (185 Gal) 30 min 3.5 kWh 18 kg (40 lbs) 30 L (8 Gal)

X-1000 1100 L (291 Gal) 35 min 4.0 kWh 20 kg (44 lbs) 35 L (9 Gal)

X-2000 2500 L (660 Gal) 45 min 9.0 kWh 40 kg (88 lbs) 50 L (13 Gal)

MODEL CAPACITY TIME ELECTRIC STEAM WATER

B-1000 1100 L (291 Gal) 35 min 4.0 kWh 20 kg (44 lbs) 35 L (9 Gal)

B-2000 2500 L (660 Gal) 45 min 9.0 kWh 40 kg (88 lbs) 50 L (13 Gal)

Bioseal

Page 4: Shred & Steam Sterilizers · (Healthcare) Red bags, sharps, other regulated medical waste. The rmwXstream ™ system is designed specifically for healthcare facilities, to treat regulated

Biowaste Sterilization | Solvent Wash & Recovery | Custom Process Skids | Service

700 Industrial Drive, Dupo IL 62239, (618) 286-5000, www.prisystems.com

Xstream-Bro-20200218

EXPERTS IN BIOHAZARDOUS WASTE MANAGEMENT SYSTEMS.

Treatment As Fast As 30 Minutes:

3.5 bars55 psi

138°C280 F

10 min

3.5 bars55 psi

138°C280 F

1. LOADING

of waste through the top opening.

2. SHREDDING

starts once the lid is closed, sealed and locked. Heavy-

duty shredder features automatic reverse rotation to

prevent jamming.

3. HEATING

via steam, raising the temperature to 300° F and pressure at 51 psi.

4. STERILIZATION

pressure and heat maintained for 10 minutes

(adjustable to meet material density). Inactivation of >106

reduction.

0 bars0 psi

80°C176 F

5. COOLING

through the flash tank lowers temperature and pressure to prepare for

system opening.

6. DRAINING

of condensate and water into sanitary drain or to an Effluent Decontamination System (EDS) if required.

7. UNLOADING

of the sterilized waste discharged into a waste tote.

The Xstream™ shreds all material once the vessel lid is closed, prior to the start of the steam treatment cycle to ensure the efficacy of the steam sterilization throughout the load. The system uses directly injected steam and pressure to sterilize throughout the infectious waste, surpassing traditional autoclaving by rendering the waste unrecognizable due to the integrated shredder system. Temperature, pressure and time are continuously monitored and maintained through the integrated control system. Achieves microbial inactivation greater than 106.

C

OMPLY WITH

S TA N D A R D S

STAATT