SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy...

40
L SHPBCKNREST 13368969 .Ezf Software Manual Backup & Restore PC-based Automation L-force Controls

Transcript of SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy...

Page 1: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

L

SHPBCKNREST13368969

.Ezf

Software Manual

Backup & Restore

PC-based Automation

L-force Controls

Page 2: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreContents

2 L 1.6 EN - 01/2011

Contents

1 About this documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.1 Document history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1.2 Conventions used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.3 Terminology used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

1.4 Definition of notes used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.1 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.1.1 Using Compact Flash cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.1.2 Structure of the »IPC Backup & Restore« . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2.2 Differences between archive, backup, and restore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.2.1 What is an archive? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.2.2 What is a backup? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.2.3 What is a restore? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.3 Using an archive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2.3.1 Archiving a CF card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2.4 Using a backup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

2.4.1 Backup with USB stick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

2.5 Using a restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

2.6 Summary of the functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

2.6.1 CF card (archive) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

2.6.2 USB stick (backup) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3 User interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

3.1 Control & function elements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

3.1.1 Title bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

3.1.2 Menu bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

3.1.3 View bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

3.1.4 Operating range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

3.2 Exit program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Page 3: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 3

Control technology | IPC Backup & RestoreContents

4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.1 Archiving and restoring Compact Flash cards (CF cards) . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

4.1.1 Duplicate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

4.1.2 Archive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

4.1.3 Unarchive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

4.2 Backup & Restore with a USB stick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

4.2.1 Backup with USB stick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

4.2.2 Restore with USB stick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

4.2.3 Update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

4.3 Device replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

5 Short menu reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

5.1 "File" menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

5.2 "View" menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

5.3 "Tools" menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

5.4 "Help" menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

6 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Your opinion is important to us. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Page 4: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreAbout this documentation

4 L 1.6 EN - 01/2011

1 About this documentation

This documentation contains information on the parameterisation and configuration ofindustrial PCs. The "PC-based automation" supports industrial PCs of the following deviceseries:

EL 1800 - EL 9800,

CS 5800 - CS 9800,

CPC 2800.

The industrial PCs are available with the following software equipment:

Industrial PC as component, on request, with operating system, without additional software

Industrial PC as visualisation system

Industrial PC as control and visualisation system

Depending on the software equipment acquired, some chapters of this Manual may beirrelevant to you.

This Manual is part of the "PC-based Automation" manual collection which consists of thefollowing documentation:

Documentation Subject

System manualsPC-based Automation

• Control technology - system structure & configuration • Visualisation - system structure & components

Communication manualsPC-based Automation

• CANopen control technology • EtherCAT control technology • PROFIBUS control technology

(Software) manualPC-based Automation

• Industrial PC - Parameterisation & Configuration

Operating InstructionsEmbedded Line Panel PC

• EL x800 - Panel PC with TFT display

Operating InstructionsCommand Station

• CS x800 - Stand-alone operator terminal

Operating InstructionsControl Cabinet PC

• CPC 2800 - Control cabinet PC

Operating InstructionsHMI EL 100

• EL 1xx - HMI with Windows® CE

Further software manuals • Global Drive Control (GDC) • IPC as gateway - Parameterisation & Configuration • »Engineer« • »PLC Designer« / »PLC Designer - SoftMotion« / »PLC Designer - CANopen

for runtime systems« • »VisiWinNET® Smart«

Page 5: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 5

Control technology | IPC Backup & RestoreAbout this documentation

Further technical documentation on Lenze components

More information on Lenze components that can be used together with "PC-basedautomation" can be found in the following documentation:

Target group

The documentation is designed for qualified skilled personnel in accordance with IEC 364.

Mounting & wiring Legend:

MA 8400 StateLine/HighLine Printed documentation

MA 9400 StateLine/HighLine Online help/PDF

MA EPM-Txxx (I/O system IP20) Abbreviations used:

MA EPM-Sxxx (I/O system 1000) SHB System Manual

MA 8200 vector BA Operating Instructions

Wiring according to EMC - 8200 vector MA Mounting Instructions

MA ECSxS/P/M/A axis modules SW Software Manual

MA ECSxE power supply modules KHB Communication Manual

for built-in units: • built-in unit • push-through technique • cold-plate technique

MA MC-CAN2 communication card

MA MC-ETC communication card

MA MC-ETH communication card

MA MC-PBM communication card

MA MC-PBS communication card

MA MC-MPI communication card

MAs for communication modules

Parameter setting, configuring, commissioning

SW 8400 StateLine/HighLine frequency inverter

SW 9400 StateLine/HighLine/PLC drive controller

9400 HighLine commissioning guide

SHB I/O system IP20 (EPM-Txxx)

SHB I/O system 1000 (EPM-Sxxx)

SHB 8200 vector

BA ECSxS axis module "Speed and Torque"

BA ECSxP axis module "Posi & Shaft"

BA ECSxM axis module "Motion"

BA ECSxA axis module "Application"

BA ECSxE power supply module

KHBs for communication modules

Page 6: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreAbout this documentationDocument history

6 L 1.6 EN - 01/2011

1.1 Document history

Tip!

Current documentation and software updates for Lenze products are available onthe Internet in the "Services & Downloads" area at:

http://www.Lenze.com

Version Description

1.0 05/2007 TD16 First edition

1.1 08/2007 TD16 Changed version due to updated software version • Screen pictures updated

1.2 10/2007 TD16 Short menu reference added

1.3 11/2007 TD16 Changed version due to updated software version • Detailed description of the Backup & Restore processes

1.4 05/2008 TD11 Changed version due to updated software version • Structure optimisation • "View" menu item added • Differences added regarding the use of the corresponding memory medium

1.5 04/2009 TD11 Updated software version (control technology 2.2) • Optimisation for selecting the software update directory • Changed user interface "IPC components for Backup / Restore".

1.6 01/2011 TD11 Updated software version (control technology 2.5) • New "Device replacement" function

Page 7: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 7

Control technology | IPC Backup & RestoreAbout this documentation

Conventions used

1.2 Conventions used

This documentation uses the following conventions to distinguish between different typesof information:

Type of information Highlighting Examples/notes

Notation of numbers

Decimal separator Point The decimal point is generally used.For instance: 1234.56

Text

Version information Blue text colour All pieces of information that only apply to or from a certain controller software version are identified accordingly in this documentation.Example: This function extension is available from software version V3.0!

Program name » « The »Engineer« Lenze PC software...

Window Italics The Message window... / The Options dialog box...

Variable identifier By setting bEnable to TRUE...

Control element Bold The OK button ... / The Copy command ... / The Properties tab ... / The Name input field ...

Sequence of menu commands

If several commands must be used in sequence to carry out a function, the individual commands are separated by an arrow: Select FileOpen to...

Shortcut <Bold> Press <F1> to open the online help.

If a key combination is required for a command, a "+" is inserted between the key identifiers: Use <Shift>+<ESC>...

Program code Courier IF var1 < var2 THEN a = a + 1 END IF

Keyword Courier bold

Hyperlink Underlined Optically highlighted reference to another topic. In this documentation activated by means of a mouse-click.

Icons

Page reference ( 7) Optically highlighted reference to another page. In this documentation activated by means of a mouse-click.

Step-by-step instructions Step-by-step instructions are marked by a pictograph.

Page 8: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreAbout this documentationTerminology used

8 L 1.6 EN - 01/2011

1.3 Terminology used

Term Meaning

Compact Flash card (CF card) The terms Compact Flash card and CF card are used synonymously. The dialogs of the user interface use the designation CF card.The CF card is the central memory medium of the industrial PC. The industrial PC cannot run without the CF card.

Page 9: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 9

Control technology | IPC Backup & RestoreAbout this documentation

Definition of notes used

1.4 Definition of notes used

This documentation uses the following signal words and symbols to indicate dangers andimportant information:

Safety instructions

Structure of the safety instructions:

Application notes

Pictograph and signal word!

(characterise the type and severity of danger)

Note

(describes the danger and gives information about how to prevent dangerous situations)

Pictograph Signal word Meaning

Danger! Danger of personal injury through dangerous electrical voltageReference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken.

Danger! Danger of personal injury through a general source of dangerReference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken.

Stop! Danger of property damageReference to a possible danger that may result in property damage if the corresponding measures are not taken.

Pictograph Signal word Meaning

Note! Important note to ensure trouble-free operation

Tip! Useful tip for simple handling

Reference to another documentation

Page 10: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreIntroductionFunctions

10 L 1.6 EN - 01/2011

2 Introduction

This chapter contains information on the function of the archive, backup, and restore. »IPCBackup & Restore« requires the Microsoft Windows® XP operating system.

2.1 Functions

The »IPC Backup & Restore« software provides the following basic functions:

1. Creation and management of archives Archive ( 25),

2. Creation of backups Backup with USB stick ( 27),

3. Update of the runtime software Update ( 31).

For archives and backups, different storage media are used. Information on the differencesbetween archives and backups and the storage media to be selected can be found in thefollowing chapters:

What is an archive? ( 12)

What is a backup? ( 12)

What is a restore? ( 12)

2.1.1 Using Compact Flash cards

Compact Flash cards of swissbit® are available in different versions.

»IPC Backup & Restore« only supports the "Fixed Disk (non removable)" version with ultra direct memory access (UDMA) which

– is used in the industrial PC as bootable memory medium,

– can be partitioned and formatted like a hard disk.

Note!

For an error-free backup and restore of data in the »IPC Backup & Restore« only Compact Flash cards of the company swissbit®, variant "Fixed Disk(non removable) with ultra direct memory access (UDMA)" are approved!

Page 11: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 11

Control technology | IPC Backup & RestoreIntroduction

Functions

Information on different Compact Flash(CF) versions

2.1.2 Structure of the »IPC Backup & Restore«

»IPC Backup & Restore« is composed of two components:

»IPC Backup & Restore« on the engineering PC under Windows® XP,

»IPC Backup & Restore« on the IPC under Windows® CE.

The contents of this documentation refer to the use of the »IPC Backup & Restore« on theengineering PC.

Further information on the use of the »IPC Backup & Restore« under Windows® CE can be found in the documentation for the industrial PC in the section »IPC Backup & Restore«.

Version Function

Fixed Disk(non removable) • The CF card can be used like a hard disk. • Partitioning and formatting is possible.

Removable Disk • The CF card can be formatted, but partitioning is not possible.

Ultra direct memory access (UDMA) Ultra direct memory access • provides direct and quicker data access to the contents of the CF card. • can only be used if the hardware supports ultra direct memory access.

Page 12: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreIntroductionDifferences between archive, backup, and restore

12 L 1.6 EN - 01/2011

2.2 Differences between archive, backup, and restore

2.2.1 What is an archive?

The term Archive describes the contents of a CF card. The archive is created underWindows® XP by the CF card.

The CF card

contains the complete "memory" of the industrial PC,

contains all permanently saved pieces of information of the IPC components such as

– the operating system,

– software,

– data.

For the industrial PC, the CF card is what the hard disk is for the engineering PC. There, all data required for operation are stored.

Using an archive

2.2.2 What is a backup?

A backup is created under Windows® CE.

With a backup, individual IPC components are copied from the CF card to a USB stick.

Using a backup ( 14)

2.2.3 What is a restore?

Restore describes the process of restoring backup data from a USB stick on the CF card.

"Restore" is for instance used to

– transfer individual components from one industrial PC to another IPC,

– restore data in the event of a defect.

Backups are restored under Windows® CE.

Using a restore ( 16)

Note!

The archive of a CF card is basically different from a backup of an industrial PC. The contents and the structure of archive and backup are different. This is why an archive can, for instance, not be replaced by a backup.

Page 13: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 13

Control technology | IPC Backup & RestoreIntroduction

Using an archive

2.3 Using an archive

You can restore the archive of a CF card on your engineering PC on a new CompactFlash card.

Tip!

How to carry out a backup or restore under Windows® CE on the industrial PC isdescribed in the chapter "Backup and Restore" of the software manual for theindustrial PC.

Archiving requires that the engineering PC is equipped with a card reader.

When archiving a CF card, the whole CF card contents will be backed up on your hard disk.

– The backed up archive can be restored on another CF card later.

– An industrial PC can be booted with a restored CF card. After inserting the CF card, the IPC can be started directly.

Using a backup ( 14)

2.3.1 Archiving a CF card

If all data bases of the CF card of an industrial PC are to be backed up on the engineeringPC, a card reader must be connected to the engineering PC.

For more information on archiving a CF card, please see:

Backup with USB stick ( 27)

Note!

Observe the differences between the storage media when restoring archives!

• A restore only restores configuration-dependent software components.

• During the restore, the whole contents of the Compact Flash card are restored.

Note!

For completely restoring a software version, the CF card must be archived. When the CF card is archived, all CF card data are backed up. Archiving therefore requires enough memory space on the CF card.

Page 14: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreIntroductionUsing a backup

14 L 1.6 EN - 01/2011

2.4 Using a backup

Whereas CF card archives represent a complete data base, USB sticks are designed for thebackup of individual IPC components.An advantage of the use of backups is the automatic backup functionality when bootingup the industrial PC. Unlike CF card archiving, the USB stick is not to be removed from theindustrial PC.

The term "Backup" describes the following process:

When creating a backup using a USB stick as storage medium on your industrial PC, components are copied from your CF card to the USB stick.

The restore of a backup on your industrial PC is called "Restore". Backups stored on a USB stick can additionally be transferred from the USB stick to an engineering PC.

The contents of a backup can be configured: Backup with USB stick ( 27)

A backup may contain maximally four IPC components:

Operating system; boot loader

Lenze software

System configuration

Data

Note!

Risk of data loss!

When duplicating or restoring a CF card, the data carrier is formatted and made bootable. When a USB stick is selected, the USB stick is afterwards no longer suitable for being used on an industrial PC!

The storage medium selected in Backup & Restore must correspond to the storage medium physically available!

IPC

USB stick

Backup

Resto

re

CF card

Up

da

te

Page 15: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 15

Control technology | IPC Backup & RestoreIntroduction

Using a backup

The more IPC components you select, the more memory space is required on your USBstick. When creating the first backup, all components should be selected. Data ( 29)

As soon as backups are created at regular intervals, we recommend only to backup the IPCcomponents that change. These are mainly data. Please read the section Backup withUSB stick ( 27) to see which data are backed up.

2.4.1 Backup with USB stick

If data of an industrial PC are to be backed up on a USB stick, the USB stick must beprepared using this software. When the USB stick is prepared, the »IPC Backup & Restore«on the industrial PC can automatically generate the required backup (depending on theconfiguration). Backups are provided with special names which contain information on theindustrial PC. The data which are considered by a backup is described under: Data ( 29)

[2-1] Backup - overview

Note!

A defect on a CF card can only be removed by restoring the archive on another CF card! When a USB stick is used, the system is always expected to be executable.

As a precaution, always create an archive from a CF card!

USB stick

CF card

EngineeringPC

IndustrialPC

Add backup

USB stick

Configure

Archive

Save backupCreate backup

USB stick

Configured

Page 16: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreIntroductionUsing a restore

16 L 1.6 EN - 01/2011

2.5 Using a restore

Restoring an archive located on the engineering PC on a Compact Flash card (CF card). Torestore data, the USB stick must be switched from the engineering PC to the industrial PC.

[2-2] Restore - overview

How to restore data contents on your industrial PC is described under: Restore with USBstick ( 16)

2.6 Summary of the functions

There is a basic difference between archiving a CF card and carrying out a backup with a USB stick:

– Archiving a CF card backs up all data sets of the CF card,

A Backup with a USB stick only backs up user data and the IPC components selected. Backups created with a USB stick are designed for the regular backup of user data!

2.6.1 CF card (archive)

Duplicate CF cards,

Archive all CF card data contents of an industrial PC on your hard disk,

Unarchive archives stored on your hard disk on CF cards.

Note!

• Restore with a USB stick only restores the IPC components previously selected,

• Restore the CF card restores all data bases of the CF card. Please observe the increased memory requirements!

USB stick

CF card

EngineeringPC

IndustrialPC

Add backup

Restore

Page 17: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 17

Control technology | IPC Backup & RestoreIntroduction

Summary of the functions

2.6.2 USB stick (backup)

Creating backups

– A backup with a USB stick only backs up user data such as PLC programs and VisiWinNET projects

Prepare the USB stick for Backup/ Restore or Update on the industrial PC.

Add to USB stick copies a backup from the hard disk to the USB stick to restore it on the industrial PC.

Delete from USB stick deletes an existing backup on the USB stick.

With Save to disk you can save a backup available on your USB stick on your hard disk.

Update your IPC software by downloading Lenze updates to a USB stick.

Note!

A backup created with a USB stick must only be restored via a USB stick.

When the contents of a CF card are archived, the contents must only be restored on another CF card.

To ensure an error-free backup and restore, only use CF cards made by the company swissbit®.

Page 18: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreUser interfaceControl & function elements

18 L 1.6 EN - 01/2011

3 User interface

This chapter describes the different control and function elements of the »IPC Backup & Restore« user interface for Windows® XP.

3.1 Control & function elements

The user interface contains the following control and function elements:

Title bar Menu bar View bar Operating range

Note!

The Select your Compact Flash card selection field only displays removable media. This prevents damage to the hard disk of the engineering PC and data loss.

Page 19: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 19

Control technology | IPC Backup & RestoreUser interface

Control & function elements

3.1.1 Title bar

In the Title bar in the upper position of the application window, the Program icon andProgram name are displayed in the left-most position and the Window icons are displayedin the right-most position:

The view of the application window can be changed via the Window icons 0 1 2 . Here, the following is distinguished:

– Icon in the Task bar ( )

– Window size ( )

When clicking the Program icon you open the System menu which also contains commands for positioning and changing the size of the application window.

Click the Window icon or double-click the Program icon to exit »IPC Backup & Restore«.

3.1.2 Menu bar

Via the Menu bar you can access all menu commands.

By clicking a main menu item you open the corresponding menu, and the menu items contained therein are displayed.

By clicking a menu item you execute the function associated.

– Menu items displayed in light grey are deactivated in the current program status.

3.1.3 View bar

CF card USB stick Device replacement

Note!

The Operating range changes depending on the view selected.

Page 20: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreUser interfaceExit program

20 L 1.6 EN - 01/2011

3.1.4 Operating range

In the Operating range the properties and settings of the element currently selected in theView bar are displayed in different tabs and can also be changed here.

When the tab in the upper position is clicked, the corresponding tab comes to the foreground.

Tip!

The individual tabs which are displayed in the Operating range depend on the typeof the element selected.

3.2 Exit program

Select the command FileExit, click the window icon in the Title bar to exit »IPC Backup & Restore«.

Page 21: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 21

Control technology | IPC Backup & RestoreOperation

4 Operation

The »IPC Backup & Restore« software serves to back up and restore data of the industrialPC on a Compact Flash card (CF card) or a USB stick.

[4-1] Menu structure - overview

What do you want to do?

Archiving and restoring Compact Flash cards (CF cards) ( 22)

Backup & Restore with a USB stick ( 27)

Note!

Risk of data loss!

When duplicating or restoring a CF card, the data carrier is formatted and made bootable. When a USB stick is selected, the USB stick is afterwards no longer suitable for being used on an industrial PC!

The storage medium selected must correspond to the storage medium physically available!

Page 22: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationArchiving and restoring Compact Flash cards (CF cards)

22 L 1.6 EN - 01/2011

4.1 Archiving and restoring Compact Flash cards (CF cards)

4.1.1 Duplicate

1. The Duplicate tab serves to write the entire contents of the CF card into a temporary directory.

2. The contents are written back to a new CF card.

3. The data in the temporary directory are deleted after having been copied.

Note!

Data archived on the engineering PC remain stored after»IPC Backup & Restore« has been uninstalled.

Note!

To ensure an error-free backup and restore, only use CF cards made by the company swissbit®.

Note!

The CF card to which the data of the temp directory is to be copied is formatted and made bootable. This deletes all data stored on the CF card!

Page 23: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 23

Control technology | IPC Backup & RestoreOperation

Archiving and restoring Compact Flash cards (CF cards)

How to duplicate a CF card:

1. Connect the CF card to be copied as the data source to the engineering PC.

2. Select the corresponding CF card from the Drive selection field.

3. Press Start.

• 1. Read in

4. Replace the read-in CF card with another CF card to which the data are to be copied.

The CF card has been read in. Insert a new CF card and press Start to start writing.

• Confirm the message window with OK.

Page 24: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationArchiving and restoring Compact Flash cards (CF cards)

24 L 1.6 EN - 01/2011

5. Insert a new CF card.

The contents of your Compact Flash card has been read in. Press Start to write to the new CF card.

Note: The CF card is formatted. This deletes all data stored on the CF card!

6. Press Start to write the data to the CF card.

• 2. Write to Compact Flash card.

• The progress bar indicates the progress of copying.

• Copying completed.

Page 25: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 25

Control technology | IPC Backup & RestoreOperation

Archiving and restoring Compact Flash cards (CF cards)

4.1.2 Archive

The Archive tab serves to recreate a backup folder. The contents of a CF card are thencopied to the directory selected.

How to copy the contents of a CF card to the hard disk:

1. Select the corresponding CF card from the Please select your Compact Flash card selection field.

2. Go to the Create a new backup directory input field andcreate a new directory.

• Click the button to open the Browse for folder dialog box.

• Click the Make new folder button in the Browse for folder dialog box to create a backup directory.

3. Press Start.

• Copying completed.

Page 26: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationArchiving and restoring Compact Flash cards (CF cards)

26 L 1.6 EN - 01/2011

4.1.3 Unarchive

The Unarchive tab serves to select an archive or to create a new archive. The contents ofthe folder are then written to the CF card selected.

How to copy the contents from an archive directory of the hard disk to a CF card:

1. Select the corresponding CF card from the Select your Compact Flash card selection field.

2. Go to the Select the backup directory that you want to restore input field and select a directory which has been created by a CF card.

• The button serves to search for a folder.

3. Press Start.

• A progress bar appears.

Note!

To ensure an error-free backup and restore, only use CF cards made by the company swissbit®.

The CF card to be restored is formatted and made bootable. This deletes all data available on the CF card!

Page 27: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 27

Control technology | IPC Backup & RestoreOperation

Backup & Restore with a USB stick

4.2 Backup & Restore with a USB stick

4.2.1 Backup with USB stick

This chapter describes how to prepare a USB stick to carry out a backup. The prepared USBstick must be connected to the industrial PC to automatically create backups on the USBstick.

Note!

Risk of data loss! Only select the USB stick when the USB stick tab is activated. The storage medium selected in Backup & Restore must correspond to the storage medium physically available!

Note!

A backup backs up all data and subfolders of the \IPC folder of the CF card.

Save data and folders you want to backup with a USB stick in the \IPC folder of the CF card.

Page 28: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationBackup & Restore with a USB stick

28 L 1.6 EN - 01/2011

Option Information

Backup files available on the USB stick

Name of a backup data package:IPCUpdate_<Processor type>_<Version> • Date/time formats: • Date = YYYYMMDD • Version=Vx.x.x.xxxExample:IPCUpdate_PM_V2.0.0.302

IPCBackup_<Prefix>_<Serial number>_<Date>_<Time> • Date/time formats: • Date = YYYYMMDD • Time = HHMMSSExample:IPCBackup_HMI_00E04B0811AF_20060101_003008

• Add to USB stick Opens a dialog for selecting a folder. An available backup can be selected and added to the USB stick.

• Delete from USB stick Deletes the selected backup file from the USB stick.

• Save to disk Opens a dialog for selecting a folder. Copies the selected backup file from the USB stick to the hard disk.

Automatic behaviour when IPC is started with the connected USB stick

• No action When the USB stick is inserted, the industrial PC boots up normally without making a backup or restore.

• Display selection dialog (only for IPCs with display)

When the USB stick is inserted, the industrial PC provides a selection dialog via which the backup or restore can be selected.

• Record new backup When booting with the USB stick inserted, a backup is automatically written to the USB stick. This is especially sensible for systems without display.

• Restore selected backup (without question)

When booting with the USB stick inserted, a restore is automatically (without a selection dialog) written from the USB stick to the industrial PC. This is especially sensible for systems without display.

Tip!Leave the USB stick connected to the industrial PC to ensure that a backup is made every time the IPC boots up. Thus, the last data bases are always available.

Record backup

• Prefix Freely configurable addition for the backup name.Tip: Use a name which can be assigned clearly later.

• Max. no. of backups Maximum number of backups which may be saved on the USB stick during the automatic backup.

The maximum number in »IPC Backup & Restore« is 100! If the maximum number of backups is reached on the USB stick, the oldest backup will be overwritten.

This value is only evaluated if "Record new backup" is selected.Recommendation: 3

IPC components for backup / restore

This area contains information about components that are saved by default when a backup is executed. • If a backup is selected for restore, you will find the components contained in the backup in this area.

• Operating system; bootloader Operating system: nk.binBoot loader which also contains the display resolution: • PM systems: CEBOOT.SYS • LX800 systems: bldr.bootini, splah.bmx

Page 29: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 29

Control technology | IPC Backup & RestoreOperation

Backup & Restore with a USB stick

How to prepare the USB stick:

1. Go to the Please select your USB stick selection field and select a USB stick.

• Backup files available on the USB stick are displayed.

2. Go to the Automatic behaviour when controller is started with the connected USB stick combination field and select an option.

3. Select the controller components for backup / restore.

4. Make other entries.

• Information on this can be found in the table.

5. Press Write control file.

After the control file has been written successfully, the USB stick is prepared for a backup.

• Lenze software The software of Cabinet(*.CAB) files type supplied by Lenze.This file manages all version numbers of the individual Cabinet files.

• System configuration Hardware identification file SWInfo.xml (not required anymore from control technology R2.2 onwards).

• Data The backup contains the following data: • Folders:

– INOSOFT, IPC, OCT, SERVICE, VisiWinNETNote: If one of the folders is not available under \STORAGE on the CF card, the backup will create an empty folder for the corresponding folder.

• Data bases:– Management.db– ValueTables.db

Tip: All data and subfolders of the IPC folder are backed up. To back up data, store them in the IPC folder

Note!

How to make a backup on the industrial PC is described in the chapter »IPC Backup & Restore« of the IPC Software Manual.

Option Information

Page 30: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationBackup & Restore with a USB stick

30 L 1.6 EN - 01/2011

How to carry out a backup:

1. Configure the USB stick with »IPC Backup & Restore« on the engineering PC.

2. Insert USB stick in industrial PC.

3. Boot up industrial PC.

4. Write backup through industrial PC to USB stick.

5. Insert USB stick in engineering PC.

6. Store data from USB stick on engineering PC.

The backup on the USB stick can be backed up on the engineering PC from the USB stick tothe hard disk of the engineering PC.

Backup & Restore with a USB stick

4.2.2 Restore with USB stick

Restore backup with USB stick

If the data of a backup are to be retransferred to the industrial PC, the USB stick must beprepared accordingly using the Backup & Restore software.

Backup & Restore with a USB stick

How to restore an existing backup:

1. Select backup with »IPC Backup & Restore« on the engineering PC.

• Add backup to USB stick.

2. Insert USB stick in industrial PC.

3. Restart industrial PC.

• Data are transferred.

4. Reboot industrial PC.

Note!

A backup created with a USB stick contains configuration-dependent software components. The CF card is not copied directly. A backup created with a USB stick is designed for the regular backup of customer data.

Page 31: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 31

Control technology | IPC Backup & RestoreOperation

Backup & Restore with a USB stick

4.2.3 Update

This function serves to prepare a USB stick for a software update of an industrial PC bytransferring the required software update to the USB stick.

The stored software update from the USB stick can then be installed on the CF card of the industrial PC.

For the control of the update process in the industrial PC the control file is additionally written to the USB stick.

Note!

• The storage medium selected in »IPC Backup & Restore« must correspond to the storage medium physically available!

• The selection of faulty configuration data may cause maloperation when the system is started! A software update only works perfectly with the software provided by Lenze.

• The Lenze software and operating system can only be updated with a USB stick! The USB stick must be formatted as FAT 16 file system!

Page 32: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationBackup & Restore with a USB stick

32 L 1.6 EN - 01/2011

How to save the software update on the USB stick:

1. Select available USB stick

2. Go to the "Select the base path for Lenze updates" selection field and select the base path which contains the folder with the updates.

• Select the directory above the version folder. Example: The software update is located in the \IPC-SoftwareUpdates\V2.2.0.xxx folder. Select the higher-level \IPC-SoftwareUpdates directory as base path:

Tip: Create a folder for filing the software updates, e.g. \IPC-SoftwareUpdates

3. Select the software version to be installed from the Controller software selection field.

4. Select the required software variant from the Runtime Software selection field:

• L-force Logic

• L-force Motion

• L-force Visu

5. Select the processor type of the industrial PC from the Processor type selection field.

6. Select the resolution of the available display from the Display resolution selection field.

Note: If the display resolution of an external display is not known,Flat_VGA_640X480 must be selected!

7. Go to the Automatic behaviour when PIC is started with the connected USB stick combination field and make the following selections.

• Select Display selection dialog (only for controllers with an external display)

Note: When this option is selected, the IPC displays a selection dialog after the start. In the selection dialog you can decide during runtime which update is to be installed. As an option, you can select Backup, Restore, or Cancel.

• Select the Install newly created update option.

Note: For industrial PCs without display, this option must be selected! The recreated update is installed automatically on the industrial PC. This option can be selected for all industrial PCs.

8. Press Start.

• The software update is written into a separate folder to the selected USB stick.

• The control file is written accordingly so that the software can be installed on the industrial PC.

The folder has the following structure: IPCUpdate_<Processor type>_<Version number>

Example: IPCUpdate_PM_2.0.0.339

This folder contains two subfolders:

Page 33: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 33

Control technology | IPC Backup & RestoreOperation

Backup & Restore with a USB stick

CAB: Lenze software

CESYS: Windows® CE operating system, boot loader

After the write process of the »IPC Backup & Restore« has been completed, the datarequired for a software update are available on the USB stick.

Then execute a software update by connecting the USB stick to the industrial PC.

Executing a software update at the industrial PC

How to execute a software update at the industrial PC:

1. Connect the USB stick described before in »IPC Backup & Restore« to the USB terminal of the industrial PC.

2. Restart the industrial PC.

• With the previously activated setting Show selection dialog carry out the instructions given in the industrial PC manual. In the case of industrial PCs with a display, the dialog window shows a dialog window with the software updates available on the USB stick.

Note!

If software update version 1.5 is used, manual steps are required which are described in the following documentation:

• "PC-based Automation": Industrial PC - parameter setting & configurationChapter "IPC Backup & Restore", section "Software update procedure".

More information on the use of the »IPC Backup & Restore« at the industrial PC can be found in the following documentation: • "PC-based Automation": Industrial PC - parameter setting & configuration chapter "IPC Backup & Restore"

Page 34: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreOperationDevice replacement

34 L 1.6 EN - 01/2011

4.3 Device replacement

A device replacement is required if a defective hardware (x700 system) is to be replacedwith the follow-up system (x800).

The Device replacement function serves to prepare the CF card of a replacement device using »IPC Backup & Restore«, so that the configuration data of IPC 1 (like for instance parameters, boot project, visualisation) can be transferred to the replacement device (x800 system).

This enables a subsequent device replacement from an x700 system to an x800 system.

o

[4-2] Basic representation of a device replacement: IPC 2 replaces IPC 1 within the machinery. CF card 2 has to be prepared using the "Device replacement" function.

Basic procedure:

1. Import CF card 1 from IPC 1 (device to be replaced including the source data) in the »IPC

Backup & Restore« ( )

2. Have CF card 2 of the replacement device converted ( )

3. Insert CF card 2 in IPC 2. ( )

• Start IPC 2 (replacement device) with CF card 2.

The IPC will then restart (several times) until the migration and the data for the display areadapted.

How to transfer the existing configuration data (source data) to the CF card of the replacement device (x800):

1. Select Device replacement tab

Page 35: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 35

Control technology | IPC Backup & RestoreOperation

Device replacement

• Select CF card with the source data (old device)

2. Press Start

• Import source data of the CF card

3. Insert CF card of the replacement device

4. Press Start

• Convert source data and write them to the CF card of the replacement device.

5. Insert CF card in the replacement device.

Page 36: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

Control technology | IPC Backup & RestoreShort menu reference"File" menu

36 L 1.6 EN - 01/2011

5 Short menu reference

This chapter contains a list of all menu commands.

5.1 "File" menu

5.2 "View" menu

5.3 "Tools" menu

5.4 "Help" menu

Icon Command Shortcut Information

Exit Exit program

Icon Command Shortcut Information

Refresh F5 Refresh the Backup/ Restore tab. The view is refreshed via the control file of the USB stick.

Icon Command Shortcut Information

Languages Language selection • German • English • Note: Stop and restart the program to activate

the change of the interface language.

Icon Command Shortcut Information

Index <F1> Display online help

Information Display information on »IPC Backup & Restore«: • Copyright • Version

Page 37: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

1.6 EN - 01/2011 L 37

Control technology | IPC Backup & RestoreIndex

6 Index

AApplication notes 9

Archiving a CF card 13

BBackup with USB stick 15

CControl elements 18

Conventions used 7

DDevice replacement 34

Differences between archive, backup, and restore 12

EE-mail to Lenze 38

Exit program 20

Exiting the program 20

FFeedback to Lenze 38

Function elements 18

Functions of the IPC Backup & Restore 10

LLayout of the safety information 9

MMenu bar 19

OOperating range 20

Operation 21

SSafety instructions 9

Structure of the safety instructions 9

TTarget group 5

Terms 8

Title bar 19

UUser interface 18

Using a backup 14

Using an archive 13

VView bar 19

WWhat is a backup? 12

What is a restore? 12

What is an archive? 12

Page 38: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

38 L

Your opinion is important to us

These instructions were created to the best of our knowledge and belief to give you the best possible support for handling our product.

If you have suggestions for improvement, please e-mail us to:

[email protected]

Thank you for your support.

Your Lenze documentation team

Page 39: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

L 39

Page 40: SHPBCKNREST L-force Controlsdownload.lenze.com/TD/Backup and Restore IPC__v1-6__EN.pdf/ The Copy command ... / The Properties tab ... / The Name input field ... Sequence of menu commands

© 01/2011

Lenze Automation GmbHHans-Lenze-Str. 1D-31855 AerzenGermany

Service Lenze Service GmbHBreslauer Straße 3D-32699 ExtertalGermany

+49 (0)5154 – 82 -0 00 80 00 / 24 4 68 77 (24 h helpline)

+49 (0)5154 – 82 - 2800 +49 (0)51 54 / 82-11 12

[email protected] [email protected]

www.Lenze.com

SHPBCKNREST 13368969 EN 1.6 TD11

10 9 8 7 6 5 4 3 2 1