Ships High Voltage system

3
Training Facilities Practical training facilities are targeted at the skills development aspect of learning at TMI. These facilities include a large, well equipped workshop, engineering infrastructure, mock-ups for fire fighting and other training plus other facilities designed to improve the seamanship training of TMI students. Commissioning of High Voltage Switch-Gear Lab Keeping in pace with the modern technology and industry need of providing much needed high voltage training in marine applications, TMI has set up a new high voltage switch-gear laboratory for imparting value added training not only to the TMI undergraduate courses but also for upgrading knowledge and skill levels of the existing seafarers. The setup consists of low voltage switch-gear, high voltage switch-gear and step up transformers. Low Voltage Switch-gear (440v)consists of two ACBs to feed power to the entire system. High Voltage Switch- gear (6.6kv) consists of two sections fed by two VCBs and connected by bus tie as VCB. Also there is provision of two outgoing feeders (VCBs) for future expansion. Two Step up transformers are used to increase voltage from 440v to 6.6kv. Transformers are oil filled type. ACBs and VCBs are Schneider Electric, German make.

description

Ships High Voltage system

Transcript of Ships High Voltage system

Page 1: Ships High Voltage system

Training Facilities

Practical training facilities are targeted at the skills development aspect of learning at TMI. These facilities include a large, well equipped workshop, engineering infrastructure, mock-ups for fire fighting and other training plus other facilities designed to improve the seamanship training of TMI students.

Commissioning of High Voltage Switch-Gear Lab

Keeping in pace with the modern technology and industry need of providing much needed high voltage training in marine applications, TMI has set up a new high voltage switch-gear laboratory for imparting value added training not only to the TMI undergraduate courses but also for upgrading  knowledge and skill levels of

the existing seafarers.

The setup consists of low voltage switch-gear, high voltage switch-gear and step up transformers. Low Voltage Switch-gear (440v)consists of two ACBs to feed power to the  entire system. High Voltage Switch-gear (6.6kv) consists of two sections fed by two VCBs and connected by bus tie as VCB. Also there is provision of two outgoing feeders (VCBs) for future expansion. Two Step up transformers are used to increase voltage from 440v to 6.6kv. Transformers are  oil filled type. ACBs and VCBs are Schneider Electric, German make.

The setup with adequate safety features are approved by the Electricity Department of  Maharashtra Government, Pune Division.

For further queries on courses, contact

Page 2: Ships High Voltage system

Mr.Laxman Tikore

Sr. Associate Professor

Tel : 02114 - 242066

Email:[email protected]

 

Marine high voltage safety courseDESCRIPTION

The course is designed to increase the troubleshooting skills and fault diagnostics procedures for marine electrical and mechanical engineers employed on various ships and offshore installations . This course will give knowledge and understanding of maritime HV installations and safety working procedures.The course will emphasize the safety aspect of electrical engineering work,recommendation on good safe safe practicies,procedures and precautions be taken to maximize the safety of personnel. The course will provide both theoretical and practical instructions in safe training enviroment.Duration of the course: 3 days

MAIN TOPICS OF THE COURSE

Theoretical:

- international requisites for high voltage knowledge- advantages of high voltage systems- hazards- high voltage equipment on board- high voltage safety rules- safe working procedures- protective devices- high voltage electrical equipment testing methods- transformer testing- high voltage equipment maintenance- drawings

Practical:

Practical excercises will be held on high voltage training cabinet.- disconnection- isolation - proving the system dead- earthing and dischraging- work permits- re enregizing the system- SF6 and vacuum breakers operating principles- protections operating principles- insulation test

Feel free to contact us at [email protected] or check our contact details for any additional info or inquiry.