Shear Wall Design Examples

26
Copyright © 2013 American Wood Council All rights reserved. 1 Presented by: “Speaker Name” Shear Wall Design Examples www.awc.org 2 Copyright Materials www.awc.org This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission is prohibited. © American Wood Council 2013

description

Identify and understand the basic shear wall system toresist wind and seismic loadsUnderstand the difference between segmented andperforated shear wall designUnderstand hold‐down designBe able to identify and analyze shear walls perthe IRC, WFCM, and SDPWS and understand thedifferences between them

Transcript of Shear Wall Design Examples

  • Copyright 2013 American Wood CouncilAll rights reserved.

    1

    Presented by:Speaker Name

    ShearWallDesignExamples

    www.awc.org

    2

    CopyrightMaterials www.awc.org

    This presentation is protected by US and International Copyright laws. Reproduction, distribution, display

    and use of the presentation without written permission is prohibited.

    American Wood Council 2013

  • Copyright 2013 American Wood CouncilAll rights reserved.

    2

    3

    LearningObjectives www.awc.org

    At the end of this program, participants will:

    IdentifyandunderstandthebasicshearwallsystemtoresistwindandseismicloadsUnderstandthedifferencebetweensegmentedandperforatedshearwalldesignUnderstandholddowndesignBeabletoidentifyandanalyzeshearwallsperthe IRC,WFCM,and SDPWSandunderstandthedifferencesbetweenthem

    Copyright 2013 American Wood Council

    4

    DesignExample1. 2009IRCBracedWalls2. 2001WFCMHighWindGuide3. 2001WFCMPrescriptive4. 2001WFCMEngineered5. 2008SDPWS

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    3

    5

    DesignExampleAssumptions100mph(3secgust)ExposureB5/12roofpitch8'wallsL=36'W=30'WoodStructuralPanelSheathing

    www.awc.org

    6

    DesignExample

    Design first floor shear wall

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    4

    7

    DesignExample1. 2009IRCBracedWalls2. 2001WFCMHighWindGuide3. 2001WFCMPrescriptive4. 2001WFCMEngineered5. 2008SDPWS

    www.awc.org

    8

    DesignExample IRC2009IRCBracedWalls

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    5

    9

    DesignExample IRC2009IRCBracedWalls

    30'spanwith5/12roofpitchEavetoridgeheight=6.25'BraceWallLength=13'(0.9)=11.7'

    www.awc.org

    10

    DesignExample IRC2009IRCBracedWalls

    ' ' OKLess than 3' NG

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    6

    11

    DesignExample IRC2009IRCBracedWalls

    Assuming 2' panel on perpendicular wall at each corner no hold-downs required (R602.10.1.4.1)

    www.awc.org

    12

    1. 2009IRCBracedWalls2. 2001WFCMHighWindGuide3. 2001WFCMPrescriptive4. 2001WFCMEngineered5. 2008SDPWS

    DesignExample www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    7

    13

    SegmentedShearWallMethod www.awc.org

    14

    PerforatedShearWallMethod www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    8

    15

    Shear/uplift anchorage design tables are found here:Wind (Exposure B)Table 3.2 Sill or Bottom Plate Connections (plf capacity)Table 3.2A Wind Shear Loads - 1/2 & 5/8 Anchor Bolts (numbers of bolts in shear wall line)Table 3.2B Wind Shear Loads - 1/2 & 5/8 Anchor Bolts (bolt spacing)Table 3.2C Wind Uplift Loads (bolt spacing)Table 3.4 Rafter/Truss Connections (lbs capacity)

    DesignExample www.awc.org

    16

    2001WFCMHighWindGuide 100mphExp.B

    L/W =36/30=1.2

    Interpolate=48.6%

    DesignExample WFCMHWG www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    9

    17

    2001WFCMHighWindGuide 100mphExp.B

    AssumesPerforatedShearWall(PSW)

    DesignExample WFCMHWG www.awc.org

    18

    7/16 wood structural panel continuous height over wall plates

    8d common nails @ 6 OC on panel perimeter

    8d common nails @ 12 OC in field

    1/2 gypsum wallboard on interior

    5d cooler nails @ 7 OC on panel perimeter

    5d cooler nails @ 10 OC in field

    panel exterior panel interior

    Here are standard assembly details for shear wall panels from 2001 WFCM 3.4.4.2

    DesignExample WFCM HWG www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    10

    19

    2001WFCMHighWindGuide 100mphExp.B

    36' x48.6%=17.5' < 21' OK

    DesignExample WFCMHWG www.awc.org

    20

    2001WFCMHighWindGuide 100mphExp.B

    PSWrequiresholddownsatendsandfullysheathedwall

    DesignExample WFCMHWG www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    11

    21

    2001WFCMHighWindGuide 100mphExp.B

    HoldDowns=4,360lbs*

    * Need to combine with top floor hold down requirements

    DesignExample WFCM HWG www.awc.org

    22

    1. 2009IRCBracedWalls2. 2001WFCMHighWindGuide3. 2001WFCMPrescriptive4. 2001WFCMEngineered5. 2008SDPWS

    DesignExample www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    12

    23

    2001WFCMPrescriptive interpolate=6.9'DesignExample WFCM www.awc.org

    24

    Segmentedshearwall

    DesignExample WFCM2001WFCMPrescriptive interpolate=6.9'

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    13

    25

    2001WFCMPrescriptiveDesignExample WFCM www.awc.org

    26

    2001WFCMPrescriptive 6.9' x1.3=9'

    Whatifwedontcountthegypsumoninterior?

    DesignExample WFCM www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    14

    27

    Segmentedshearwall assumingnointeriorgypsum13' >9' OK

    2001WFCMPrescriptive required=9'DesignExample WFCM www.awc.org

    28

    Segmentedshearwall requiresholddownsoneachsegment

    2001WFCMPrescriptive HolddownsDesignExample WFCM www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    15

    29

    Hold Downs*= 3,488 lbsw/ gypsum

    3,488 / 1.3= 2,683 lbsw/o gypsum

    * Need to combine with top floor hold down requirements

    2001WFCMPrescriptive HolddownsDesignExample WFCM www.awc.org

    30

    PSWrequiresholddownsatendsandfullysheathedwall

    DesignExample WFCM2001WFCMPrescriptive PSW

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    16

    31

    % Full-height sheathing21' / 36' = 58%

    Interpolated= 1.34

    6.9'(1.34) = 9.2'w/ gypsum

    9'(1.34) = 12.1'w/o gypsum

    21' Full-height sheathing > 12.1' OK

    DesignExample WFCM2001WFCMPrescriptive PSW

    www.awc.org

    32

    1. 2009IRCBracedWalls2. 2001WFCMHighWindGuide3. 2001WFCMPrescriptive4. 2001WFCMEngineered5. 2008SDPWS

    DesignExample www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    17

    33

    2001WFCMEngineeredwroof =82plfwfloor =103plfwtotal =185plf185(30')/2=2,775lbs

    DesignExample WFCM www.awc.org

    34

    DesignExample WFCM2001WFCMPrescriptive Engineered

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    18

    35

    RequiredCapacity=2,775lbs7/16WSP=240plf240(1.4)=336plf (Footnote1)Gypsum=100plf (Table3C)Total=436plf2,775/436=6.4'(w/gypsum)2,775/336 =8.3' (w/ogypsum)

    DesignExample WFCM2001WFCMPrescriptive Segmented

    GypsumWallboard2 1/2 5d Cooler Nails Unblocked74

    10031253

    www.awc.org

    36

    2,775 lbs

    8' > 6.4' assuming interior gypsum OK

    DesignExample WFCM2001WFCMEngineered Segmented

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    19

    37

    2,775 lbs

    13' > 8.3' assuming NO interior gypsum OK

    DesignExample WFCM2001WFCMEngineered Segmented

    www.awc.org

    38

    SupplementTable3BV=2,775lbsv=436plf (w/gypsum)v=336plf (w/ogypsum)%FHSheathing=58%InterpolatedFactor =0.62436(0.62)=270plf2,775/270 =10.3' (w/ gypsum)336(0.62)=208plf2,775/208=13.3'(w/ogypsum)

    DesignExample WFCM2001WFCMEngineered PSW

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    20

    39

    21' Full-height sheathing > 13.3' OK

    DesignExample WFCM2001WFCMEngineered PSW

    www.awc.org

    40

    T=vhv=436plf (w/gypsum)v=336plf (w/ogypsum)h=8'T=436(8')=3,488lbsT=336(8')=2,688lbs*Need to combine with top floor

    hold down requirements

    DesignExample WFCM2001WFCMEngineered Holddowns

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    21

    41

    1. 2009IRCBracedWalls2. 2001WFCMHighWindGuide3. 2001WFCMPrescriptive4. 2001WFCMEngineered5. 2008SDPWS

    DesignExample www.awc.org

    42

    2008SDPWS WSPCapacity

    ASDCapacity=670/2=335plf

    DesignExample SDPWS www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    22

    43

    ASDCapacity=200/2=100plf

    DesignExample SDPWS2008SDPWS GypsumCapacity

    www.awc.org

    44

    RequiredCapacity=2,775lbsWSP=335plfGypsum=100plfTotal=435plf2,775/435=6.4'(w/gypsum)2,775/335=8.3'(w/ogypsum)

    DesignExample SDPWS2008SDPWS GypsumCapacity

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    23

    45

    2,775 lbs

    DesignExample SDPWS2008SDPWS SegmentedShearWall

    www.awc.org

    46

    Co =0.62w/gypsum435(0.62)=2702,775/270=10.3'w/ogypsum335(0.62)=2082,775/208=13.3'21'Fullheightsheathing>13.3' OK

    DesignExample SDPWS2008SDPWS PerforatedShearWall

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    24

    47

    DesignExample SDPWS2008SDPWS PerforatedShearWall

    2,775 lbs

    www.awc.org

    48

    T=vhv=2,775/8' =347plfh=8'T=347(8')=2,775lbs**Need to combine with top floor

    hold down requirements

    DesignExample SDPWS2008SDPWS Holddowns*(Segmented)

    www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    25

    49

    V=2,775lbsh=8'Co =0.62Li =21'T=1,705lbs*Need to combine with top floor

    hold down requirements

    DesignExample SDPWS2008SDPWS Holddowns*(PSW)

    www.awc.org

    50

    Code/Standard Segmented ShearWallLengthPerforatedShear

    WallLengthHolddown

    Requirements

    2009IRCBracedWalls 11.7' n/a none2001WFCMHighWindGuide n/a 17.5' 4,360lbs2001WFCMPrescriptive 6.9'(9') 9.2'(12.1') 3,488(2,683)lbs2001WFCMEngineered 6.4'(8.3') 10.3'(13.3') 3,488(2,688)lbs

    2008SDPWS 6.4'(8.3') 10.3'(13.3') 2,775lbs1,705lbs(PSW)

    1st of2Story;30' span;5/12pitch; 100mphExp.B

    Parentheticalvaluesassume NOinterior gypsum

    DesignExample Summary www.awc.org

  • Copyright 2013 American Wood CouncilAll rights reserved.

    26

    51

    www.awc.org

    [email protected]

    Questions?