Setup Guide - Textalk · 2019. 2. 13. · Manual Calibration - If the Auto Calibration is unable to...

26
Setup Guide Left Mouse-click or use left and right arrow keys to navigate between slides.

Transcript of Setup Guide - Textalk · 2019. 2. 13. · Manual Calibration - If the Auto Calibration is unable to...

  • Setup Guide

    Left Mouse-click or use left and right arrow keys to navigate between slides.

  • Table of Contents

    Click on a link below to jump directly to a section.

    ● Basic Requirements

    ● Load Software

  • Basic Requirements

    ● Windows 7 or 8.1 computer● Processor: 2GHz Dual Core or better (AMD or Intel)

    ● Memory: 2GB RAM DDR2 or more

    ● Graphics: Intel HD 4000 or better (Must support minimum resolution of 1280x720)

    ● Disk Space: 500MB or more

    ● USB 2.0 port

    ● HDMI or VGA port for TV or projector connection

    ● *Internet connection recommended for software activation

    ● *Use with TV or monitor may require filter material

    ● Video projector or TV that will display a minimum of 1280x720 resolution

    o Some 1024x768 projectors will still display a 1280x720 signal in

    widescreen mode.

    ● Flat white wall or projection screen for projector use.

    ● Indoor area with controllable lighting conditions.

  • Load Software

    1. Locate the included software disk or download

    the installer from this link Smokeless Range

    Installer

    2. Load the disk into DVD drive. Make sure it

    seats into the mini DVD pocket in the tray.

    3. Open the DVD drive folder and run the

    SmokelessRange.exe

    4. Once the installation is complete a How to

    Setup video will auto play to walk you through

    a first time setup.

    https://www.dropbox.com/s/pur1o2kxnzp7ii0/SmokelessInstall.exe?dl=0

  • Plug in USB Camera

    1. Plug in the camera into a

    USB 2.0 port on your

    computer.

    2. Allow the camera driver to

    load before proceeding.

    (Depending on your

    computer, this can take a

    minute)

  • 1280x720 Minimum Resolution

    ● Make sure your computer and projector can

    display at a minimum 1280x720 resolution.

    ● The software will look correct at 1280x720 or

    higher resolution.

  • Turn Off Antivirus

    Some antivirus programs will not allow the

    Smokeless Range software to launch. If you

    have problems with the software not running try

    turning off your antivirus or creating an

    exception in the antivirus firewall for the

    Smokeless Range.

  • Lighting

    For the system to work best, the laser tracking camera needs to see only the projected image or TV. A lamp or window

    in direct view of the camera, like off to the side or behind the screen, will blind the camera from being able to see the

    laser reflect off the TV or projection screen.

    Bright light next to screen Windows next to screen

  • System Setup with Projector

    ● The projector can be either floor or ceiling mounted

    ● Projector should be set to display the same thing as the desktop

    ● Flat white wall or low gain projection screen should be used.

  • System Setup with TV

    ● Camera placed in front of TV on a table or stand so that camera is at least

    level with bottom of TV.

    ● Some setups may work better with the camera off to one side on a tripod

    looking down at the TV if ceiling lights reflecting in the image are a problem.

    ● TV set to display same thing as desktop.

    ● Use with TV or monitor may require filter material (GAMFusion 10-55 /

    20”x24”) 2 sheets will cover a 50” TV.

    http://www.bhphotovideo.com/c/product/166152-REG/Gam_GC1055_GamFusion_10_55_Diffusion_Material.html

  • System Setup with TV (cont.)

    TV Image SettingsSome TVs will crop off the outside edges of your computers image. The camera calibration must be able to see the

    entire image or the calibration will not be possible. This more likely to be the case when using an HDMI cable vs a VGA

    cable to connect the TV to your laptop. If your image is cut off, review the next slide on how to fix it.

    Incorrect (Edge cut off) Correct image

  • System Setup with TV (cont.)Every TVs setting menu is different, so you will have to refer to your user manual or look through the menu to find the

    correct setting for your TV. Below is where the setting is found on a Samsung TV as an example.

    Menu / Picture / Picture Options Size

    Changed from 16:9 to

    Screen Fit

  • System Setup with TV (cont.)Mounting the GAMFusion 10-55 / 20”x24”

    Filter 1 Filter 2

    TV Screen

    ● The filter material is only needed on screens that do not reflect the laser back

    bright enough for the camera to track it. And if you have problems with reflected

    light on your TV screen.

    ● Mount flat to screen surface. Some screens are set back from the bezel.

    ● Attach with Scotch Tape

    ● Edge but the 2 sheets in the middle with no gap and no overlap

    *Example using 2 sheets to cover 50” TV

    Example on next slide

  • System Setup with TV (cont.)

    Filters taped to the screen Filter does not impede viewing the screen

    Scotch Tape used to attach to

    screen. Will not leave residue

    when removed after training.

  • System Setup with TV (cont.)

    Calibration on a TVCalibrating on a TV is different than on a projector screen. First, a TV is a direct light

    source where a projector screen is reflected light from the projector. Second, the screen

    is smaller so the camera is closer to the TV. Both of these factors mean the image is

    brighter so the camera will have a harder time distinguishing the laser from the image.

    Also, some TVs, like plasma Tvs, have a glass face over the screen, and this can reflect

    lights that are behind the camera causing hot spots in the camera image.

    Continue on to the next slide to walk through how to manage these factors and

    successfully calibrate your camera.

  • System Setup with TV (cont.)

    Launch the DF Series camera software from the

    desktop icon.

    Align the camera so that the TV

    image fills up as much of the

    camera view as possible

    without cutting off any of the

    image.

    Place the camera at an angle to

    the TV so that reflection of lights

    on the TV are minimal.

    If needed, the camera can be

    placed off to the side on a tripod

    looking down at the TV so that

    ceiling lights are not reflected in

    the image.

  • System Setup with TV (cont.)

    Reflection of open

    windows to the side of the

    TV.

    Reflection of open

    windows to the side of the

    TV.

    Ceiling lights reflecting in

    the image.

    Example of bad reflections on the screen

  • System Setup with TV (cont.)Ways to correct for the light reflections

    ● Close blinds and curtains on windows. Thin curtains will not be enough. You may need to hang a blanket over the windows in order to

    block out the sunlight.

    ● Turn off problem lights if possible without making it too dark to train.

    ● Use the GAMFusion 10-55 / 20”x24” filter material to help diffuse and mask the reflected light.

    ● If ceiling light reflection is still a problem with the GAMFusion filter material, mount the camera off to the side of the TV on a tripod

    looking down at the TV to get rid of ceiling light reflection.

    Camera sitting on tripod and

    slightly off to the left of the

    screen. This eliminated the

    reflection of the can lights in the

    ceiling.

    Closing the blinds and the

    curtains helped to greatly

    reduce the amount of sunlight

    reflecting off the TV screen.

    Mounting the GAMFusion filter

    material on the TV further

    eliminated the glare of reflected

    lighting on the TV screen and

    helping the laser to reflect back

    to the camera for accurate

    tracking.

  • System Setup with TV (cont.)Manual Calibration if auto calibration failsBecause of the less than than favorable lighting conditions that sometimes accompany calibrating on a TV, you may

    need to fall back to performing a manual calibration.

    DF Series User Guide

    Once done with calibration continue to next slide.

    Click on this link to refer to the DF Series user manual

    which cover manual calibration in detail. Then return to this

    guide to finish the setup.

    Ceiling lights reflecting off

    the TV bezel. These may

    keep the auto calibration

    from working and a

    manual calibration may be

    needed.

    https://www.dropbox.com/s/rf5396vc90s4h19/DF-Series User Manual.pdf?dl=0

  • Camera Calibration

    The camera must be calibrated in order for the system to correctly track the training laser hit location

    on the screen. This can be done by an auto calibration process, if lighting conditions are favorable, or

    a manual calibration if they are not.

    Launch DF Series Software

    To run the calibration software, locate the DF-Series Camera icon on the desktop and double click. If there is not an

    icon on the desktop go to the Windows Start menu / All Programs / Laser Ammo / Smokeless Range / and click DF-

    Series Camera.

  • Camera Calibration (cont.)

    Align the camera so that the projected image fills as much of the camera view as possible. Ensure

    there are no light sources such as lamps or windows in the view of the camera.

  • Camera Calibration (cont.)

    Click the Calibrate button on the bottom of the screen. The software will now flash a series of white dots to align the camera to the

    screen. Once the calibration is complete a test tracking screen will be displayed. This screen allows you to test the accuracy of

    the calibration.

    Note: If the auto calibration gets stuck and does not complete, hit the Esc (escape) key to return to the camera preview screen.

    Then you can read the Troubleshooting section of this manual to try to correct the problem.

  • Camera Calibration (cont.)

    If the alignment needs adjusting, click the Points button. This screen will allow you to manually adjust

    each of the 25 calibration points as needed.

  • Camera Calibration (cont.)

    To adjust a point click it with the mouse and it will turn green. Then you can either drag it with the

    mouse or use the arrow keys on your keyboard to adjust the point.

    Once you are done making adjustments click the Points button again to go back to the Test Tracking

    or click Save to minimize and launch tracking.

  • Camera Calibration (cont.)

    Manual Calibration - If the Auto Calibration is unable to complete due to undesirable lighting

    conditions you can use the Manual Calibration to calibrate the camera.

    Click the Manual button to begin manual calibration. You will be presented with 25 dots. The dots must

    be selected from top to bottom and left to right.

    Select dot 1 by left mouse clicking in the top left corner of Dot 1. Notice

    that the 4 corner dots are really pie shaped. These dots should be

    selected at the point of the pie shape. Also notice that the edge dots that

    are between the 4 corners are half circles. They should be selected in the

    middle of the flat edge. The rest of the whole circle Dots shout be

    selected in the center.

    Once you have placed a control point by left clicking you can either click

    and drag with the mouse or use the arrow keys on your keyboard to

    make adjustments to the control point before moving on.

    Once all Dots are selected click Save. This will take you to the Test

    Tracking screen.

  • Software Activation

    Online Activation -