Setting relay

download Setting relay

of 8

description

relat setting

Transcript of Setting relay

Sheet: Protection - 1 phaseSheet: Configuration - 1 phasePCD Settings Data SheetUnit informationName/Reference:Catalog Number:PCD Serial number:Note: All settings below are included in the Setting - Primary, Alternate 1 and Alternate 2 menus. In WinPCD, the settings in grey below are split into a second menu, called Primary (Alt1 or Alt2) Settings - RecloserSelectionDescriptionUnits/ValuePrimary SettingAlternate 1 SettingAlternate 2 Setting51P Curve SelectSlow Phase Curve. This curve cannot be disabled.Protection Curve51P Pickup AMinimum Tripping current for phase overcurrent. Setting is in primary amps for VR's or Cooper retrofits, secondary amps for units w/ 5 A secondaries. Amps51P Time Dial/DelayY axis (time) multiplier for selected curveSeconds51P Min RespDelays tripping to a minimum time. Does not apply for definite time or standard inverse curvesSeconds51P Time AdderAdds a definite amount of time to each point in the curve selectedSeconds50P-1 Curve SelectProtection Curve50P-1 Pickup XTripping value Multiples of 51P50P-1 Time Dial/DelaySeconds50P-1 Min RespSeconds50P-1 Time AdderSeconds50P-1 Curve Block (C.Block)Disables tripping for this particular curve above this value. Can be used for preventing co-tripping.Multiples of 51P50P-2 SelectDefinite time protection curve. Commonly used for high current tripping.Enable/Disable50P-2 Pickup XMultiples of 51P50P-2 Time DelaySeconds50P-2 Curve Block (C.Block)Multiples of 51P50P-3 SelectEnable/Disable50P-3 Pickup XMultiples of 51P50P-3 Time DelaySeconds46 Curve SelectProtection Curve46 Pickup AmpsMin Trip Value (A)46 Time Dial/DelaySeconds46 Min RespSeconds46 Time AdderSeconds51N Curve SelectProtection Curve51N Pickup A (Min Trip Val.)Amps51N Time Dial/DelaySeconds51N Min RespSeconds51N Time AdderSeconds50N-1 Curve SelectProtection Curve50N-1 Pickup XMultiples of 51N50N-1 Time Dial/DelaySeconds50N-1 Min RespSeconds50N-1 Time AdderSeconds50N-1 Curve Block (C.Block)Multiples of 51N50N-2 SelectEnable/Disable50N-2 Pickup XMultiples of 51N50N-2 Time DelaySeconds50N-2 Curve Block (C.Block)Multiples of 51N50N-3 SelectEnable/Disable50N-3 Pickup XMultiples of 51N50N-3 Time DelaySeconds67P Curve SelectProtection Curve67P Pickup A (Min Trip Val.)Amps67P Time Dial/DelaySeconds67P Min RespSeconds67P Time AdderSeconds67P Torque AngDegrees67N Curve SelectProtection Curve67N Pickup A (Min Trip Val.)Amps67N Time Dial/DelaySeconds67N Min RespSeconds67N Time AdderSeconds67N Torque AngDegrees1-Ph ModeApplies only for 1ph tripping. OOAP mode is One Or All Phases which means if the fault involves one phase, only one phase will trip. If the fault involves more than one phase, all three phases will trip. OPUP mode is Only Picked Up Phases, or the unitOOAP/OPUP79 Reset TimeAfter this time expires, unit resets its tripping sequence to the first operation. Seconds79-1 Functions51PSee Section X50P-1 " "50P-2 " "50P-3 " "51N " "50N-1 " "50N-2 " "50N-3 " "79-1 Open TimeTime which the unit will stay open after the 1st trip. If set to "lockout" the unit will not reclose and will lockout.Seconds/Lockout79-2 Functions51PSee Section X50P-1 " "50P-2 " "50P-3 " "51N " "50N-1 " "50N-2 " "50N-3 " "79-2 Open TimeTime which the unit will stay open after the 2nd trip. If set to "lockout" the unit will not reclose and will lockout.Seconds/Lockout79-3 Functions51PSee Section X50P-1 " "50P-2 " "50P-3 " "51N " "50N-1 " "50N-2 " "50N-3 " "79-3 Open TimeTime which the unit will stay open after the 1st trip. If set to "lockout" the unit will not reclose and will lockout.Seconds/Lockout79-4 Functions51PSee Section X50P-1 " "50P-2 " "50P-3 " "51N " "50N-1 " "50N-2 " "50N-3 " "79-4 Open TimeTime which the unit will stay open after the 1st trip. If set to "lockout" the unit will not reclose and will lockout.Seconds/Lockout79-5 Functions51PSee Section X50P-1 " "50P-2 " "50P-3 " "51N " "50N-1 " "50N-2 " "50N-3 " "79-5 Open TimeTime which the unit will stay open after the 1st trip. If set to "lockout" the unit will not reclose and will lockout.Seconds/Lockout79 Cutout TimeDisable/Seconds79V SelectEnable/Disable79V Pickup VSecondary Volts79V Time DelaySecondsCold Load TimeDisable/Seconds2 Phase 50PEnable/Disable81 Select byte : 3934 Disable/81-1/81-281S-1 Pickup FrequencyHertz81S-1 Time DelaySeconds81R-1 Pickup FrequencyHertz81R-1 Time DelaySeconds81S-2 Pickup FrequencyHertz81S-2 Time DelaySeconds81R-2 Pickup FrequencyHertz81R-2 Time DelaySeconds81V Voltage BlockSecondary Volts27 SelectEnable/Disable27 Pickup VoltageSecondary Volts27 Time DelaySeconds59 Select byteEnable/Disable59 Pickup VoltageSecondary Volts59 Time DelaySeconds32P SelectEnable/Disable32P Torque AngDegrees32N SelectEnable/Disable32N Torque AngDegreesFor units with Sensitive Earth Fault option (SEF)SEF Torque AngleSEF Pickup mASEF Neutral Cold LoadPCD Configuration Settings Data SheetUnit informationName/Reference:Catalog Number:PCD Serial number:SelectionDescriptionUnits/ValueConfiguration SettingsRecloser ModeGlobal setting for Single/Three Phase operationSingle/Three PhaseCT Ratio For setting CT ratio for PCD's w/ 5 amp secondaries - Not required for Cooper Retrofit or VR-3SRatioSEF CT RatioFor SEF type PCD2000'sRatioVT RatioNearest Secondary VoltageRatioVT ConnectionSecondary VT connection69V Wye/120V Wye/120V Delta/208V DeltaPositive Seq Reactance/mi (X/M)Parameter used for fault location. These parameters are determined from utilities feeder system study(X/M)Positive Seq Resistance/mi (R/M) " "(R/M)Zero Seq Reactance/mi (X/M) " "(X/M)Zero Seq Resistance/mi (R/M) " "(R/M)Line LengthLength of subject feeder for use in fault locationMilesBreaker Fail ModeSelection for attempted operation of recloser upon a breaker failure. Open tries 3 times to open upon in failure mode, Original leaves it in the state the recloser was in at the time of the problemOpen/OriginalTrip Failure TimeTime which the PCD2000 waits to signal a breaker failure alarm and to follow breaker failure logicCyclesClose Failure TimeTime which the PCD2000 waits to signal a breaker failure alarm and to follow breaker failure logicCyclesClose Delay TimeTime which the PCD2000 waits to signal a breaker failure alarm and to follow breaker failure logicCyclesCurve SetDelay timer for performing a manual closeANSI/IEC/RecloserPhase RotationForward (ABC) or reverse (ACB) rotation, used for directional elements ABC/ACBProtective ModeMethod of determining overcurrent valuesFundamental/RMSAlternate 1 SettingGlobal selection for Alternate Settings group 1Enable/DisableAlternate 2 SettingGlobal selection for Alternate Settings group 1Enable/DisableCold Load Timer ModeSelection of seconds or minutes for cold load timeSeconds/Minutes79V Timer Mode79V function prevents reclosing if there is an undervoltage condition. Selection in seconds or minutesSeconds/MinutesVoltage Display ModeDisplay format for power meteringVl-n/VllFrequencySystem Frequency50/60 HertzTarget ModeSelection for displaying only the last fault on the phase/ground indicating targets on the front of the PCD2000 vs. displaying all previous faults. Pressing the [C] button clears the targetsLast/AllWHr DisplaySelection for KW MeteringKWHr/MWHrLCD LightSetting for LCD light, Timer Mode is recommended to save life on lightOn/TimerRemote EditAllows disabling the ability to change settings from the HMI. Data records can still be accessed.Enable/DisableIDData label for Customer useUp to 15 Alpha Numeric CharactersDemand MinutesValue for use in load profile and demand metering5/15/30/60LCD ContrastSetting for LCD contrastTypically ~45 in Winter, ~55 in SummerRelay PasswordPassword required to access settings and operation menus4 Alpha Numeric CharactersTest PasswordPassword required to4 Alpha Numeric Characters