Service Manual – PB Series REV NO - noscomexico.com · This manual will help you with proper...

22
1 Service Manual – PB Series REV NO : 3 PB Series Service Manual LAST Rev. NO : 3 LAST Rev. Date : 2010. 01. 28

Transcript of Service Manual – PB Series REV NO - noscomexico.com · This manual will help you with proper...

1

Service Manual – PB Series REV NO : 3

PB Series

Service Manual

LAST Rev. NO : 3 LAST Rev. Date : 2010. 01. 28

2

Service Manual – PB Series REV NO : 3

Table of Contents 1. Proper Operation / Introduction...................................................................................................................... 3

1.1. Preface .................................................................................................................................................. 3

1.2. Precaution.............................................................................................................................................. 3

2. Classification ................................................................................................................................................... 4

2.1. Overall View.......................................................................................................................................... 4

2.2. Display Pad (Key Pad) .......................................................................................................................... 4

2.2.1. PB ................................................................................................................................................ 4

3. Getting Started ................................................................................................................................................ 5

3.1. Sealing Method...................................................................................................................................... 5

4. Calibration Mode ............................................................................................................................................. 6

4.1. General Calibration ............................................................................................................................... 6

4.1.1. C4 Setting .................................................................................................................................... 7

4.1.1.1. C4-1 Setting ............................................................................................................................. 7

4.1.2. SPAN Calibration Setting (C-3) .................................................................................................. 8

4.1.3. Gravity Constant Value Setting (C-9) ........................................................................................ 8

4.1.4. Calibration factor Setting (C-10)................................................................................................ 8

4.1.6. Percent Calibration (C-7) ........................................................................................................... 9

4.1.7. Battery Calibration (C-8) .......................................................................................................... 10

5.The Schematics and Diagram ........................................................................................................................ 10

5.1.System Block Diagram ......................................................................................................................... 10

5.2.Circuit Diagram..................................................................................................................................... 11

5.2.1.Main PCB .................................................................................................................................... 11

5.2.2.Power PCB(Main PCB) ............................................................................................................... 12

6. Servicing & Parts Replacement.................................................................................................................... 12

6.1. Trouble Shooting................................................................................................................................. 12

6.2. Error Message..................................................................................................................................... 13

7. Options Installing........................................................................................................................................... 14

7.1. Serial Interface(RS-232C) .................................................................................................................. 14

6.2. Serial Interface(RS-232C) .................................................................................................................. 14

8. ROM Download Method................................................................................................................................. 15

9. Exploded Views & Parts List........................................................................................................................ 17

9.1. Exploded View .................................................................................................................................... 17

9.2. Loadcell Ass’y..................................................................................................................................... 19

9.3. Main PCB Ass’y (Top) ........................................................................................................................ 20

9.4. Main PCB Ass’y (Bottom) ................................................................................................................... 20

3

Service Manual – PB Series REV NO : 3

1. Proper Operation / Introduction

1.1. Preface Thank you for purchasing of our CAS scale.

This scale has been designed with CAS reliability, under rigid quality control

and with outstanding performance.

WE hope that your departments enjoy with high quality of CAS product.

This manual will help you with proper operations and care of the PB(Portable Bench).

Please keep it handy for the future references.

1.2. Precaution • Make sure that you plug your scale into the proper power outlet.

• Place the scale on a flat and stable surface.

• Plug into a power outlet 30 minutes before operations.

• Keep the scale away from strong EMI noises may cause incorrect weight readings.

• This scale must be installed in a dry and liquid free environment.

• Do not subject the scale to sudden temperature changes.

• Do not subject the platter to sudden shocks.

• If the scale is not properly level, please adjust the 4 legs at the bottom of the scale (turn

legs clockwise or counterclockwise) so as to center the bubble of the leveling gauge

inside the indicated circle.

4

Service Manual – PB Series REV NO : 3

2. Classification

2.1. Overall View

2.2. Display Pad (Key Pad) 2.2.1. PB

5

Service Manual – PB Series REV NO : 3

Key Function

ZERO (-O-)

[Set]

To set zero point

To do [SET] key in the SETUP mode.

TARE To input or cancel the tare (the weight of container).

HOLD To make the weight of item stable. This weight is average value.

POWER To turn on or off.

3. Getting Started

3.1. Sealing Method

-

6

Service Manual – PB Series REV NO : 3

4. Calibration Mode

4.1. General Calibration Pressing and holding calibration switch press [POWER] key to go to calibration mode.

User can move to other mode by using [ZERO] key in the calibration mode.

User also moves to other sub-modes for each mode by using [TARE] key.

Please simply follow below procedure to move to other mode.

(1) Calibration Mode: Pressing and holding “Calibration Switch” press [POWER] key.

(2) It displays “CAL-0” after “CAL”, and it blinks the version of scale three times.

(3) Selecting menu: press [TARE].

(4) ENTER(Setting) : [TARE] key

MODE Function

CAL 1 Display normalized AD

CAL 2 Display Keypad infomation-

CAL 3

Weight Setting Mode

“UnLoad” [TARE] → →

“MIDD” [TARE] after loading for 1/3 weight → →

“FULL” [TARE] after loading for Full weight → →

“MIDD” [TARE] after loading for 1/3 weight “END”→ →

CAL 4 Option Setting ( Refer to Table 1)

CAL 5 Display filtered Raw AD

CAL 7 % Calibration

CAL 8 Battery calibration

CAL 9 Gravity constant

CAL 10

Set calibration factor “Unit” [TARE] select 0, 1 (0:kg, 1: lb) [TARE] “CAPA” [TARE] select capacity [TARE] “MCAPA” [TARE] select mid-capacity [TARE] “W-dP” [TARE] Select Decimal Point [TARE] “ 1 d ” [TARE] Select division [TARE] “Dual” [TARE] Enable dual interval (0:disable, 1:enable) [TARE] “tare” [TARE] Enable custom tare (0:disable, 1:enable) [TARE]

CAL 11 Set nation(00 : OIML , 01 : NTEP , 02: KOREA)

7

Service Manual – PB Series REV NO : 3

4.1.1. C4 Setting 4.1.1.1. C4-1 Setting

3 5%

2 10%

1 3% BIT 6~7 Initial Zero range

0 2%

0 Disable BIT5 Last digit enable

1 Enable

0 ±3% key zero percent BIT4 Key zero percent

1 ±2% key zero percent

3 (+), (-) All Direction successive Tare

2 (+) Direction successive Tare

1 (-) Direction successive Tare BIT 2~3 Successive tare

0 One Time tare

0 Gross zero indication

1 Net zero indication BIT0~1 Zero mark type

2 Both(gross and net) zero indication

4.1.1.2. C4-3 Setting

0 "." dot BIT7 Dot Type

1 "," comma

0 Don't use BIT6

Use Preset tare

(PB can’t use) 1 Use

0 Don't use BIT5 Use Back light

1 Use

0 Don't use BIT4

Use Head message

(PB can’t use) 1 Use

0 Don't use BIT3 Use gram

1 Use

0 Don't use BIT2 Use oz

1 Use

0 Don't use BIT1 Use lb

1 Use

0 Don't use BIT0 Use Kg

1 Use

8

Service Manual – PB Series REV NO : 3

4.1.2. SPAN Calibration Setting (C-3) (1) Pressing and holding “Calibration Switch” press [POWER] key.

After “CAL” message blinks three times and shows the version of scale, it displays “CAL 1” message.

(2) Press [ZERO] to display “CAL-3”.

(3) Press [TARE] key and then it displays “zero ” message.

(4) Press [TARE] key and then it displays “midup” message

(5) Load middle weight (ex:1/3 full capacity) on the platform

(6) Press [TARE] key and then it displays “span ” message

(7) Load full weight on the platform

(8) Press [TARE] key and then it displays “middn” message

(9) Load middle weight (ex:1/3 full capacity) on the platform

(10) Press [TARE] key and then it display “CAL 3” message

4.1.3. Gravity Constant Value Setting (C-9) Current gravitational Acceleration value is set to 9.7994 m/s2 .

(11) Pressing and holding “Calibration Switch” press [POWER] key.

After “CAL” message blinks three times and shows the version of scale, it displays “CAL-1”

message.

(12) Press [ZERO] to display “C-9”.

(13) Press [TARE] key, and then “ G-1“ message and “9.7994” will be shown. The first

digit,”9” will blink.

(14) Input a gravitational acceleration value by using [ZERO] key.

(15) Press [TARE] key, and then “G-2“ message blinks.“9.7994” will be shown. The first

digit,”9” will blink.

(16) Input a gravitational acceleration value by using [ZERO] key.

(17) Press [TARE] key to save the gravitational acceleration value, and “C-9 ” message will be

shown.

4.1.4. Calibration factor Setting (C-10) (1) Pressing and holding “Calibration Switch” press [POWER] key.

(2) After “CAL” message blinks three times and shows the version of scale, it displays “CAL-1”

message.

(3) Press [ZERO] to display “C-10”.

(4) Press [TARE] key, and then “UNIT “ message and “0” will be shown. The first digit,”0”

will blink. It means calibration unit is “kg” (0 : kg, 1 : lb)

(5) Input a calibration unit by using [ZERO] key.

(6) Press [TARE] key, and then “CAPA“ message blinks.“0015” will be shown. The first digit,”0”

will blink. It means a full-capability is “15 (calibration unit, kg or lb)”

(7) Input a capability by using [ZERO] key.

9

Service Manual – PB Series REV NO : 3 (8) Press [TARE] key, and then “MCAPA“ message blinks.“0005” will be shown. The first

digit,”0” will blink. It means a mid-capability is “05 (calibration unit, kg or lb)”

(9) Input a capability by using [ZERO] key.

(10)Press [TARE] key, and then “W-dP “ message blinks.“3” will be shown. The first digit,”3”

will blink. It means a weight decimal point is “3 (will display 0.000)”

(11)Input a weight decimal point by using [ZERO] key.

(12) Press [TARE] key, and then “1d “ message blinks.“0.005” will be shown. The third

digit,”0” will blink. It means a division is “0.005 (calibration unit, kg or lb)”

(13) Input a division by using [ZERO] key.

(14) Press [TARE] key, and then “dual “ message blinks.“1” will be shown. The third digit,”1”

will blink. It means a dual interval is disable. (0 : disable, 1 : enable)”

(15) Input a dual interval enable by using [ZERO] key.

(16) Press [TARE] key to save the calibration factor, and “ C-10 ” message will be shown.

- CAL METHOD (SPAN ,%)

- PROGRESSED TEST FACTS IN CAL MODE

- SETTING IS RELATED TO KEY VALUE

- SETTING FACTS IN THE OTHER CAL MODES (Gravity setting)

- SETTING FACTS IN SET MODE: INCLUDE A FUNCTION

4.1.5. Displaying Real A/D Value (C-5) Display Raw AD

4.1.6. Percent Calibration (C-7) (1) Pressing and holding “Calibration Switch” press [POWER] key.

After “CAL” message blinks three times and shows the version of scale, it displays “CAL 1”

message.

(2) Press [ZERO] to display “CAL-7”.

(3) Press [TARE] key and then it displays “per 0 ” message. Select the percent value using the

[numeric] key. You can choose 10~90 percent. (Last digit of percent must be 0.)

(4) Press [TARE] key and then it displays “zero” message

(5) Press [TARE] key and then it displays “pspan ” message

(6) Load choice percentage weight of full weight on the platform

(7) Press [TARE] key and then it displays “CAL 7” message

10

Service Manual – PB Series REV NO : 3

4.1.7. Battery Calibration (C-8) (1) Pressing and holding “Calibration Switch” press [POWER] key.

After “CAL” message blinks three times and shows the version of scale, it displays “CAL 1”

message.

(2) Press [ZERO] to display “CAL-8”.

(3) Press [TARE] key and then it displays voltage of battery.

(4) Change the jumper-pin of main PCB, ‘BAT’ to ‘+5V’.

(5) Press [ZERO] key two times and then Press [-] key two times.

And then it display ‘500’

(6) Change the jumper-pin of main PCB, ‘+5V’ to ‘BAT’.

(7) You can see the calibrated voltage of battery.

5.The Schematics and Diagram

5.1.System Block Diagram

11

Service Manual – PB Series REV NO : 3

5.2.Circuit Diagram

5.2.1.Main PCB

TP6

TP-B1

TP7

TP-B1

KEY & BUZZER PART

Q1 KTA1666

SOT892

1

3BK1

LED_BLDBB_BL5_Bty pe

2 1468

357

BUZZER

C2100uF/16VCE66N

Q3KTA1504

SOT23-21-3

2

13

S5

CAL_SWSSW1

2

R12

10kΩ

R11

100kΩR13

10kΩR14100kΩ

BL_CON

TARE

ZERO

BL_CON

R15 100kΩBUZZER

+3.3V

+3.3V

+3.3V+3.3V

C101nF

C81nF

C91nF

R18 100kΩ

R19 100kΩ

Q2

2N2222SOT23-21-3

2

31

R20 100kΩ

TARE

C30.1uF

C40.1uF

C70.1uF

C50.1uF

U2A

max3232idbre4MTC16

V-6

RIN28

C2- 5

RIN113

V+2

C2+ 4ROUT2 9

GN

D15

ROUT1 12DOUT2 7

C1-3

DOUT1 14

C1+1

DIN210 DIN111 V_C

C16

C60.1uF

Tx

RxCON_TX

CON_RX

S1 ZERO

1 2

ZERO

S2 TARE

1 2

R5 100Ω

S3 HOLD

1 2

R7 100Ω

Title

Size Document Number Rev

Date: Sheet of

0.3

PB-LCD MAIN CIRCUITB

1 2Monday , December 22, 2008

+3.3V

CON_TX

+5V

BAT_CHK

POWER_CHK

VOLT_CHK

R16100kΩ

JP1

SIP\2P12

R17100kΩ

6100-PPB-0000-0

BZ1

SIG_IN+

SIG_IN-

+5V

LCD_DATA

LCD_WR

LCD_CS

R1 10Ω

MODULE CONNECTOR PART

CAL PARTPROGRAM PART RS232 CONNECTOR PART

LOADCELL PARTU10

OneModuleONE_MODULE_MOLDING

A_Vcc1

A_GND2

Bat_chk3

P1.64

P1,75

Rx6

Tx7

P3.28

P3.39

P3.410

P3.511

P3.612

P3.713

P2.014

P2.115

P2.216

P2.317

P1.118

AIN+ 36

AIN- 35

A_GND 34

P1.0 33

P0.0 32

P0.1 31

P0.2 30

P0.3 29

P0.4 28

P0.5 27

P0.6 26

P0.7 25

PSEN 24

I2C_SDA 23

I2C_CLK 22

D_Vcc 21

D_GND20

RTC_Power19

PSEN

Rx

CAL

Tx

+3.3V

POWER_CON

CAL

CN2

RJ11-ModularJack-6p

11

2 2

3 3

4 4

5 5

6 6

HOLD

S12

S15S14S13

S18S17S16

S21S20

LCD_DATA

LCD_WR

LCD_CS

S19

C0

S23S22

S23S22

C3C2C1

S16S17S18S19S20S21

S14S15

S8S9S10S11S12S13

S4S5S6S7

C2C3S0S1S2S3

+5V

C0C1

C1

0.1uF

R10

2.2kΩ

L6

1 2

+5V

U1

HT1621b48PIN-TMP

SEG71

SEG62

SEG53

SEG44

SEG35

SEG26

SEG17

SEG08

CS9

RD10

WR11

DATA12

VSS13

OSCO14

OSCI15

VLCD16

VDD17

IRQ18

BZ19

BZ20

COM021

COM122

COM223

COM324

SEG8 48

SEG9 47

SEG10 46

SEG11 45

SEG12 44

SEG13 43

SEG14 42

SEG15 41

SEG16 40

SEG17 39

SEG18 38

SEG19 37

SEG20 36

SEG2135

SEG22 34

SEG2333

SEG24 32

SEG25 31

SEG26 30

SEG27 29

SEG28 28

SEG29 27

SEG30 26

SEG31 25

CN1

LC5PINA

1

2

3

4

5

DISPLAY & BACK LIGHT PART

SIG-

SIG+

EX-

EX+L1

1 2

LCD1LCD_MW_CAS_28P

123456789

10111213141516171819202122232425262728

FG

L5

1 2

L2

1 2

L3

1 2

S1S0

S4S3S2

SIG_IN-

SIG_IN+

R8 100Ω

R6 100Ω

L4

1 2

S5

R9 100Ω

S8S7S6

S11S10S9

PSEN

CON_RX

HOLD

12

Service Manual – PB Series REV NO : 3

5.2.2.Power PCB(Main PCB)

U4 XC6204C502MRSOT-25

VIN1

VSS

2

CE3VOUT 5

R38100kΩ

CN5

DRY BATMX5267-2

12

D101N5819

DO-214AC(SMA)

C24470uF/25VCE12.5N

C23470u/25VCE12.5N

Pb 6V/1.25A

Mg 1.5V/2.85A×4

+9V

R31 100kΩ

R282.2kΩ

-

+

U9B

LM393SO8-3.9MM

5

67

84

+9V

-

+

U9A

LM393SO8-3.9MM

3

21

84

+9V

BATT

D9

LED BI-COLOUR2TONE-LED

1 32

R352.2kΩ

+9VR33

10kΩ

R34

100kΩ

R3647kΩ

R30

1kΩ

R27

33kΩ

+9V

CN4

Pb BATMX5267-2

12 POWER-Red

POWER-Green

C27100uF/16VCE66N

C14100uF/16VCE66N

D8

KDS184SOT23-21-3

21

3

R23100kΩ

+3.3V

R310kΩ

FUSE1

FASTBLOW / 1.6A 250V

FUSEHOLDER2

1 234

U8 XC6204C332MRSOT-25

VIN1

VSS

2

CE3VOUT

5

C260.1uF

C280.1uF

Power PARTVOLT_CHK

BAT_CHK

Title

Size Document Number Rev

Date: Sheet of

6100-PPB-0000-0 0.3

PB LCD POWER CIRCUIT DIAGRAM

A3

2 2Monday , December 22, 2008

BATT

R2410kΩ

D7SS14DO-214AC(SMA)

U6 MC34063ASO8-3.9MM

COMP5

TCAP 3VCC6

GND 4

DC8

PK7

SWC1

SWE2

L8 220uHCOIL470

POWER_CHK

POWER_CON

C130.1uF

D1

SS14DO-214AC(SMA)

D4

SS14DO-214AC(SMA)

D5

SS14DO-214AC(SMA)

R26100Ω

C22470pFC0805I

R321kΩ

R220.33Ω 2WR1W

R252.2kΩ

R29100kΩ

+5V

D6

1N5406DO-201AD

1 2

C250.1uFC0805I

L9

FERITEEMI-BEAD

CN3

Adaptor

SIP-3P-H

123

S4ON/OFFSSW

12

Charge

RECHARGEABLE BATTERY +5V

TP5

+3.3V

1

+3.3V

TP2

IN

1

TP3

GND

1

C15220uF/16VCE66N

D2

MA2Q735

L7

22uHIDT-CR54

JP2

12

TP4

BAT

1

C1247uF/16VTantal

JP3

12

C16

0.1uF

C17330uF/25VCE10X5N

A_Vcc

U7

XC6368A503MR

EXT5

VDD2

CE3 VOUT 1

GN

D4

C110.1uF

(+5V , Bat)전원사양

U3 LM7809TR\TO252-3

IN1 OUT 3

GN

D4

Q5

2N2222SOT23-21-3

2

31

+9V

Q4 KTA1666

SOT892

1

3

Q6XP161A1265PR

SOT893

1

2

R39100kΩ

R21 10kΩ

C18

0.1uFC0805I

Charge indication PART

R3747kΩ

TP1

+5V

1

R4100kΩ

6. Servicing & Parts Replacement

6.1. Trouble Shooting

SYMPTOM PROBABLE CAUSE REMEDY

ERROR 0 (unstable error)

1)The Scale is not put on the flat

part.

2)A Vibration or wind is exist

around The Scale.

- Check a foot. (Foots are must

all touched in flat part.)

-Check a PCB’s field ground.

(Field ground is must connected

to platform.)

ERROR 1(initial zero) 1)The Scale is not operate

Calibration

2)Cable is not connected

between Loadcell and PCB.

-Operate Calibration.

-Check a L/C and PCB. (L/C and

PCB are must connected.)

13

Service Manual – PB Series REV NO : 3 Batt -> Error 0 1)ONEMODULE(A/D Converter)

is damaged.

2)The Scale is not operate

Battery Calibration

-Check a battery voltage(C-8)

and then operate a battery

calibration.

-Check the A/D value. (C-1) If

place a weight, A/D value have to

changed.

NOT OPERATION(POWER OFF) 1)Power ON/OFF Key is

damaged.

2) Battery discharge or not

connected.

3)Fuse is down.(Open)

4)Power cable is down.

-Check a output voltage, holding

a Tact S/W.

-Check a battery connection and

Battery voltage.

-Check a fuse connection

6.2. Error Message

ERROR LIST REASONS SOLUTION

"Err 0" The "Err 0" occurs when scale is not stable. Remove unstable facts.

"Err 1" The "Err 1" occurs when a current zero point has shifted from the last span calibration.

Please call your CAS dealer.

"Err 2" The "Err 2" is not a real error. Only it prompts return CAL switch to the normal position.

Please call your CAS dealer.

"Err 3" The "Err 3" is an overload error. Please remove the weight.

"Err 9"

The "Err 9" is no weight error. When scale is in counting mode, you must load the weight.

If you have no weight on your scale, you can see this error message.

Please load the weight on your tray.

“Err 11”

The "Err 11" means a writing error of the internal nonvolatile memory. To recognize this error, be sure to check the voltage on the circuit and do calibration procedures.

If it still has "Err 11", replace the digital module.

“Err 12” The "Err 12" warns that the scale has lost the parameters for weighing regulations or has lost the factors for a digital span calculation.

Enter each condition codes again.

Please try a span calibration again if still not fixed.

“Err 14” The "Err 14" means calibration range is not correct. Please call your CAS dealer.

14

Service Manual – PB Series REV NO : 3

7. Options Installing

7.1. Serial Interface(RS-232C)

6.2. Serial Interface(RS-232C)

15

Service Manual – PB Series REV NO : 3

8. ROM Download Method

(1) Connect a RS-232C Cable, between the scale and PC and then excute a O/M Downloader

program.

(2) Check a ‘Communication port’ and click the ‘Init. Erase Command’. And then Click the ‘Start

Download’, Communication port will be “Ready” status.

16

Service Manual – PB Series REV NO : 3

(3) Push a ‘Open ROM File’ button and then open the ROM File.

(4) If click the ‘Start Download’ holding a power ON/OFF key, You will see ROM Downloading

display and then ROM download will be finished.

17

Service Manual – PB Series REV NO : 3

9. Exploded Views & Parts List

9.1. Exploded View 9.1.1. Display Ass’y

18

Service Manual – PB Series REV NO : 3

9.1.2. Scale Ass’y

19

Service Manual – PB Series REV NO : 3

9.2. Loadcell Ass’y

20

Service Manual – PB Series REV NO : 3

9.3. Main PCB Ass’y (Top)

9.4. Main PCB Ass’y (Bottom)

21

Service Manual – PB Series REV NO : 3

9.4.1. Main PCB(Part List)

22

Service Manual – PB Series REV NO : 3

9.4.1. PCB-Option (Part List)

NO CAUSE DATE APPROVAL

3 PCB Artwork, Part List, Calibration

Setting , Options Installing Revison 2010.01.28 Kim kwanghyun