Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU...

5
Server Technology Technical Data Sheet -48VDC Switched Rack PDU 48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs Sep 2016 | Version 1.0 This Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use this PDU to manage equipment in remote sites, co-location facilities and network operation centers. This PDU eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using this PDU, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.

Transcript of Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU...

Page 1: Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU 48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs Sep 2016 |

Server TechnologyTechnical Data Sheet

-48VDC Switched Rack PDU48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs

Sep 2016 | Version 1.0

This Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use this PDU to manage equipment in remote sites, co-location facilities and network operation centers. This PDU eliminates the need to dispatch a �eld service technician for manual intervention when devices lock-up. Using this PDU, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.

Page 2: Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU 48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs Sep 2016 |

Circuit Protection• All fuses/breakers are sold separately. Fuses/breakers and their values must be speci�ed at time of order• For fuses KIT-0094 is required, for breakers KIT-0097 is required

Inputs • Connector: 2 pair of 3/8-16 Stainless Steel Lugs • Rating: 600A each -48VDC

Outputs • Connector: 16 pair of 1/4-20 Stainless Steel Lugs • Rating: 125A maximum each -48VDC

Master PDU Link PDU Input VoltageOutputsInputs Rated Power

48DCXB-16-2X600-E048DCWB-16-2X600-E0 (2) 600A Inputs 57.6kW @ -48VDC(16) Switched Outputs125A Max

North America

-40 to -60 VDC

Features and Speci�cations

Disconnect Rated Circuit ProtectionEach output is protected by a fuse or circuit breaker and is rated for hot disconnect.

Output ControlCycle power to individual outputs or groups of outputs to reboot devices or to power o� unused terminals.

Output Current MonitoringNetwork monitoring provides access to current draw at each output and alerts when high usage risks a tripped circuit.

10A P/N FUSE-TPC-1015A P/N FUSE-TPC-1520A P/N FUSE-TPC-2025A P/N FUSE-TPC-2530A P/N FUSE-TPC-3040A P/N FUSE-TPC-4050A P/N FUSE-TPC-5060A P/N FUSE-TPC-6075A P/N FUSE-TPC-75100A P/N FUSE-TPC-100125A P/N FUSE-TPC-125

TPC Fuses 30A P/N CB-0005-030G50A P/N CB-0005-050G60A P/N CB-0005-060G70A P/N CB-0005-070G100A P/N CB-0005-100G

Breakers

Page 3: Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU 48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs Sep 2016 |

Physical/Environmental• Dimensions: 4U - 7.0" (176 mm) tall x 17.0" (432 mm) wide x 32" (813 mm) deep | Weight: 125 lbs (57 kg)• Shipping Dimensions: 40” x 35" x 24” (102 cm x 90cm x 61 cm) | Weight: 138 lbs (62.6 kg)

• Operating Environment: 32°F to 104°F / 0°C to 40°C | 8%RH to 90%RH non-condensing | 6,500ft/2000m elevation• Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation

Optional Accessories• EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)

• SPM (Sentry® Power Manager):- Monitor and manage multiple PDUs from a single point- Monitor and manage alarm conditions- Create reports and trends on stored data- Analyze power usage per phase- Optional appliance or virtual version- VMware Ready²

Communications and Security • 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)• Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) – {also on Link CDU}• Web-browser GUI and command-line-interface (CLI): HTTP/HTTPS, TLSv1, SSHv2, Telnet, SNMPv2c and v3

(GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

• cTUVus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07 + A1:2011

• EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A• FCC Class A, Part 15

Certi�cations

• TUV T-Mark to EN 60950-1:2006 + A11 + A1 + A12

• CE Mark

Page 4: Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU 48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs Sep 2016 |

AA

BB

CC

DD

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

SER

VER

TEC

HN

OLO

GY,

INC

PRO

PRIE

TAR

Y IN

FOR

MAT

ION

TH

IS D

OC

UM

ENT

IS T

HE

SOLE

PR

OPE

RTY

OF

SER

VER

TEC

HN

OLO

GY,

INC

.TH

E R

ELEA

SE O

F D

ATA

CO

NTA

INED

IN T

HIS

DO

CU

MEN

T AN

D T

HE

REP

RO

DU

CTI

ON

OF

THIS

DO

CU

MEN

T, IN

WH

OLE

OR

IN P

ART,

WIT

HO

UT

THE

WR

ITTE

N P

ERM

ISSI

ON

OF

SER

VER

TEC

HN

OLO

GY,

INC

IS P

RO

HIB

ITED

.

THES

E C

OM

MO

DIT

IES

, TEC

HN

OLO

GY

OR

SO

FTW

ARE

WER

E EX

POR

TED

FR

OM

TH

EU

NIT

ED

STA

TES

IN A

CC

OR

DA

NC

E W

ITH

TH

E EX

POR

T AD

MIN

ISTR

ATIO

NR

EGU

LATI

ON

S. D

IVER

SIO

N C

ON

TRAR

Y T

O U

.S. L

AW IS

PR

OH

IBIT

ED.

RoH

S C

OM

PLIA

NT

FIN

ISH

:

MAT

ERIA

L:

SCAL

E:BSIZE

CAG

E C

OD

ED

WG

NO

.

SHEE

T

REV

SERV

ER T

ECHN

OLO

GY,

INC.

DR

AWIN

G T

ITLE

:

10

40 S

andh

ill D

rive

Ren

o, N

V 89

521

049V

0

THIR

D A

NG

LE P

RO

JEC

TIO

ND

O N

OT

SCAL

E D

RAW

ING

* R

EMO

VE

ALL

BU

RR

S A

ND

SH

ARP

ED

GE

S .2

R M

AX

* D

IMEN

SIO

NIN

G &

TO

LER

AN

CIN

G IA

W A

SM

E Y

14.5

M-2

007

* IN

TER

PR

ET

DR

AW

ING

IAW

AS

ME

Y14

.100

-200

0

* D

IMEN

SIO

NS

AR

E IN

MIL

LIM

ETE

RS

UN

LES

S O

THE

RW

ISE

SP

ECIF

IED

NO

NE

412-

4812

5-4

1

OU

TLIN

E D

RAW

ING

, EN

A-48

125-

4G

1 O

F 1

* DIM

EN

SIO

NAL

LIM

ITS

APPL

Y A

FTER

PLA

TIN

G/C

OA

TIN

G.

TOLE

RAN

CES

(UN

LESS

OTH

ERW

ISE

SPEC

IFIE

D)

LIN

EA

R D

IME

NSI

ON

S:.X

= ±

.500

.XX

= ±

.300

.XX

X =

± .1

30

ANG

ULA

R D

IME

NS

ION

S:X

= ±

X.X

= ±

.5°

X.X

X =

± .2

Q #

= C

RIT

ICAL

DIM

.

S=

CO

SME

TIC

SU

RFA

CE

SYM

BOLS

RE

VISI

ON

HIS

TOR

YZO

NE

REV

DES

CR

IPTI

ON

DA

TEA

PPR

OVE

D-

GP/RA

M5102/41/9

NGIS

ED L

AITINI

1

NO

TES

:

1.

DIM

ENS

ION

S AR

E IN

MIL

LIM

ETER

S

AN

D [

] BR

AC

KETS

AR

E IN

INC

HES

.

MO

UN

TIN

G T

RA

Y

2X 9

0° M

OU

NTI

NG

BR

ACK

ET

455.

80 [1

7.94

]

469.

00 [1

8.46

]48

2.00

[18.

98]

177.

80 [7

.00]

711.

20 [2

8.00

]

432.

00 [1

7.01

]

Page 5: Server Technology Technical Data SheetServer Technology Technical Data Sheet-48VDC Switched Rack PDU 48DCWB-16-2X600-E0 : 57.6kW (2) 600A Inputs and (16)125A Max Outputs Sep 2016 |

available at the time of purchase. See the Support Options on the website, or contact your local Server Tech-nology representative for more information.

Patents: Information on Server Technology patents is available on the website at:

www.servertech.com/products/patents

PRO2, HDOT, PIPS, POPS, CDU, Sentry, Server Technology, the ST Eye logo, and the globe logo are U.S. registeredtrademarks of Server Technology, Inc. Power Pivot, EZip, and StartUp Stick are trademarks of ServerTechnology, Inc.

Information in this document is current as of time of publishing. Contact your Server Technology representa-tive for the most up-to-date information. © 2016 Server Technology, Inc.

¹ Cisco EnergyWise is a U.S. registered trademark of Cisco Technology, Inc.

² VMware and VMware Ready is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions.

Additional Information

Central Europe, Eastern Europe and RussiaNiederlassung DeutschlandServer Technology LLC42119 WuppertalGermanyTel: + 49 202 693917 x 0Fax: + 49 202 [email protected]

HEADQUARTERS - NORTH AMERICAServer Technology, Inc.1040 Sandhill DriveReno, NV 89521United States1.775.284.2000 Tel1.775.284.2065 [email protected]

Western Europe, Middle East and AfricaServer TechnologyFountain Court2 Victoria SquareVictoria StreetSt. AlbansAL1 3TFUnited Kingdom+44 (0) 1727 884676 Tel +44 (0) 1727 220815 [email protected]

APACServer TechnologyRoom 2301, 23/F, Future Plaza111-113 How Ming Street, Kwun Tong, Hong KongDirect line: +852 3916 2048Fax Line: +852 3916 [email protected]