SERIES - MV3-5 · 2020. 12. 8. · MV3-5-B-Y-HU R HY HU R HY HU R HY HU 3 3 DIRECT CHECK VALVES...

2
MV3 - 5 - T - X MV3 - 5 - P - Y - R MV3 - 5 - A - Y MV3 - 5 - B - Y MV3 - 5 - A - Y - * - B - Y- * Basic Characteristics Approx. Weights Operating Pressure (maximum) - 315 bar (4500 psi) Rated Capacity (maximum) - 120 L/min MV3 - 5 = 2.9 kg General Description Functional Symbols These Modular Valves are self-operating spring loaded poppet type single or dual check units. Location of the check element can be in the "A", "B", "P" or "T" port. A check in the "P" port is available as "Y" single check model only. A check in the "T" port is available as an "X" single check model only. The dual check unit has identical check elements in both the "A" and "B" port. Check Valve cracking (opening) pressure of (15 psi) (36 psi) (73 psi) are available. SERIES - MV3-5 ORDERING INFORMATION 5 & 8. Control Line - Direction to check function X = Free Flow from Load Y = Free Flow to Load 1. Model Code - MV 2. Model Series - 3 Typical Model Code :- MV3 - 5 - A - Y -R - 30 MV3 - 5 - A - Y -R - B - Y - R - 30 6 & 9. Cracking Pressure - R = 15 psi HY = 36 psi HU = 72 psi 4. Port Operated Upon - A = Check in A port (Y model only-single or dual) B = Check in B port (Y model only-single) P = Check in P port (Y model only-single) T = Check in Ta port (X model only-single) 3. Arrangement - CETOP 5 1 2 3 4 5 6 7 8 9 10 MV 3 - - 5 * - * (B * - * - * - ) - 30 - * - 7. Port Operated Upon - B = Check in B port (dual check model only) 10. Design No – 30 (Subject to change) DIRECT CHECK VALVES 22

Transcript of SERIES - MV3-5 · 2020. 12. 8. · MV3-5-B-Y-HU R HY HU R HY HU R HY HU 3 3 DIRECT CHECK VALVES...

Page 1: SERIES - MV3-5 · 2020. 12. 8. · MV3-5-B-Y-HU R HY HU R HY HU R HY HU 3 3 DIRECT CHECK VALVES MV3-5 "A" port p is different than "B" port due to internal construction. "HU" "HY"

MV3 - 5 - T - X MV3 - 5 - P - Y - R

MV3 - 5 - A - Y MV3 - 5 - B - Y

MV3 - 5 - A - Y - * - B - Y- *

Basic Characteristics

Approx. Weights

Operating Pressure (maximum) - 315 bar (4500 psi)

Rated Capacity (maximum) - 120 L/min

MV3 - 5 = 2.9 kg

General Description

Functional Symbols

These Modular Valves are self-operating spring loaded poppet type single or dual check units. Location of the check element can be in the "A", "B", "P" or "T" port. A check in the "P" port is available as "Y" single check model only. A check in the "T" port is available as an "X" single check model only. The dual check unit has identical check elements in both the "A" and "B" port. Check Valve cracking (opening) pressure of (15 psi) (36 psi) (73 psi) are available.

SERIES - MV3-5

ORDERING INFORMATION

5 & 8. Control Line - Direction to check functionX = Free Flow from LoadY = Free Flow to Load

1. Model Code - MV

2. Model Series - 3

Typical Model Code :- MV3 - 5 - A - Y -R - 30 MV3 - 5 - A - Y -R - B - Y - R - 30

6 & 9. Cracking Pressure -R = 15 psiHY = 36 psiHU = 72 psi

4. Port Operated Upon -A = Check in A port (Y model only-single or dual)B = Check in B port (Y model only-single)P = Check in P port (Y model only-single)T = Check in Ta port (X model only-single)

3. Arrangement - CETOP 5

1 2 3 4 5 6 7 8 9 10

MV 3 - - 5 * - * (B * - * - * - ) - 30- *-

7. Port Operated Upon -B = Check in B port (dual check model only)

10. Design No – 30 (Subject to change)

DIRECT CHECK VALVES

22

Page 2: SERIES - MV3-5 · 2020. 12. 8. · MV3-5-B-Y-HU R HY HU R HY HU R HY HU 3 3 DIRECT CHECK VALVES MV3-5 "A" port p is different than "B" port due to internal construction. "HU" "HY"

psi bar

40030

350

300250

150

10050

0 0

10

15

20

"HU"

"HY"

"R"

"P"

"A""B"

200

5

25

20 40 60 80 100 120

5 10 15 20 25 30Flow rate

0

I/min

US gpm

Pre

ssu

re C

on

tro

l

"A" port p is different than "B" port due tointernal construction.

Graph 2

Model type

Curve referencefor flow path

Graph number

MV3-5-P-Y-R

MV3-5-T-X-R

MV3-5-A-Y-R

MV3-5-B-Y-R

MV3-5-A-Y-*-B-Y-*

P T A B

RHYHU

P

P

P

P

T

T

T

T

A

A

1

B

B

1

2

3

1

Flow towards actuator Flow from actuatorUse R,HY,HU curve from graph 3 as applicable

MV3-5-P-Y-HYMV3-5-P-Y-HU

MV3-5-T-X-HYMV3-5-T-X-HU

MV3-5-A-Y-HYMV3-5-A-Y-HU

MV3-5-B-Y-HYMV3-5-B-Y-HU

RHYHU

RHYHU

RHYHU

3

3

MV3-5DIRECT CHECK VALVES

"A" port p is different than "B" port due tointernal construction.

"HU"

"HY"

"R"

"T""A"

"B"

psi bar

350 25

300

250

200

150

100

50

0 0

5

10

15

20

0

20 40 60 80 100 120I/min

US gpm30252015105Flow rate

Pre

ssu

re C

on

tro

l

Graph 1

"HY"

"HU"

"R"

2

1 "T"

"P"

Pre

ssure

Contr

ol

psi bar

350 25

20 40 60 80 100 120I/min

US gpm30252015105Flow rate

300

250

200

150

100

50

0 0

5

10

15

20

Graph 3

2

2

Operating data

Hydraulic fluids, temperature range Filtration -ISO 4406 code 18/150 0 0and filtration recommendations Operating temp.-0 to 82 C (32 to 180 F)

Fluid viscosity - 8 - 51 cSt (52-250 SUS) Fluorocarbon seals are standard and are suitable for use with phosphate ester type fluids or their blends, water glycol, water-in-oil emulsion fluids and petroleum oil.