Series Hybrid Inverter 3.0/3 6/5 - SegenSolar Data Sheet.pdf · EM Series Hybrid Inverter...
Transcript of Series Hybrid Inverter 3.0/3 6/5 - SegenSolar Data Sheet.pdf · EM Series Hybrid Inverter...
EM SeriesHybrid Inverter3.0/3.6/5.0kW
Max. power output up to 5kWIP65 dust-proof and water-proof rating Easy remote monitoring via PCs,tablets and mobilesFanless low-noise design
Integrated charge controller and inverterIntelligent battery management functionGrid-tied or grid-independent operationCompatible with both lead-acid and Li-ion batteriesIncreased performance and security
How does it work?
DC, currentDC, no currentAC, currentAC, no current
Mode�1
① First, Energy to load.
② Then charge battery.
③ Third, transfer energy to grid.
PV energy produced is used for self-consumption.
The excess energy is used to recharge the
batteries, then any surplus is transferred to the gridIf the grid fails, the system will automatically switch to back-up mode and use the battery stored energy
When the PV system is not generating, and the battery is charged, the inverter will supply the load from the battery first, and if this is not sufficient, it will also draw power from the grid.
Mode�3DC, currentDC, no currentAC, currentAC, no current
Mode�2DC, currentDC, no currentAC, currentAC, no current
■ www.goodwe.co.uk ■ 0333 358 3184 ■ [email protected]
Technical Data GW3048-EM GW5048-EM
3900
3300
550
100~500
125
11
1
1
MC4/ Phoenix/ Amphenol
Lead-acid or Li-Ion
48
50
50 (configurable)
≥50 (depending requirement)
3-stage adaptive with maintenance
60 (configurable)
Included (Li-Ion)
Integrated
Integrated
3000
3000
13.6
50/60Hz; 230Vac
45~55Hz/55~65Hz; 180~270Vac
<1.5%
0.8 leading~0.8 lagging
Single phase
10
2300
3500,10sec
97.6%
>97.0%
99.9%
94.5%
Integrated
Integrated
Integrated (optional)
Integrated
Integrated
347*432*175
16
Wall bracket
-25~60°C
0~95%
4000 m(> 3000m derating)
IP65
Natural convection
<25
LED light & APP
USB; RS485;CAN;WiFi
5
4600
4000
550
100~500
125
11/11
2 (can parallel)
2
MC4/ Phoenix/ Amphenol
Lead-acid or Li-Ion
48
50
50 (configurable)
≥50 (depending requirement)
3-stage adaptive with maintenance
60 (configurable)
Included (Li-Ion)
Integrated
Integrated
3680
3680
16
50/60Hz; 230Vac
45~55Hz/55~65Hz; 180~270Vac
<1.5%
0.8 leading~0.8 lagging
Single phase
10
2300
3500,10sec
97.6%
>97.0%
99.9%
94.5%
Integrated
Integrated
Integrated (optional)
Integrated
Integrated
347*432*175
17
Wall bracket
-25~60°C
0~95%
4000 m(> 3000m derating)
IP65
Natural convection
<25
LED light & APP
USB; RS485;CAN;WiFi
5
VDE-AR-N 4105, AS4777.2, VDE0126-1-1, G83/G59, CEI 0-21
Solar
Max. allowed PV Power [W]
Nominal DC Power [W]
Max. DC voltage [V]*MPPT voltage range [V]
Starting feed voltage [V]**Max. DC current [A]
No. of DC connectors
No. of MPPTs
DC connector
Battery
Battery type
Norminal Voltage [V]
MAX Charge Current [A]***Max Discharge Current [A]
Battery capacity [Ah]****Charging curve
Max Charge voltage [V]
Battery temperature compensation
Battery voltage sense
Current shunt
AC Output Data (On-grid)
Norminal AC power [W]
Max. AC power [W]
Max. AC current [A]
Norminal AC output
AC output range
THDi
Power factor
Grid connection
AC Output Data (Back-up)
AC output (Back-up)
Max.AC current [A]
Norminal AC power [VA]
Peak power [VA]
Efficiency
Max. efficiency
Euro efficiency
MPPT adaptation efficiency
Max Battery efficiency
Protection
Residual current monitoring unit
Anti-islanding protection
DC switch (PV)
AC over current protection
Insulation monitoring
Certifications & Standards
Grid regulation
Safety
EMC
General Data
Dimensions (WxHxD) [mm]
Weight [kg]
Mounting
Ambient temperature range
Relative humidity
Max. operating altitude
Protection degree
Cooling
Noise emision [dB]
Display
Communication
Standard warranty [years]
GW3648-EM
230Vac ±2%, 50Hz (60Hz Optional)±0.2%,
THDv<3%(linear load),Single phase
IEC62109-1&-2,IEC62040-1
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-3-11, EN61000-3-12
6500
5500
550
100~500
125
11/11
2 (can parallel)
2
MC4/ Phoenix/ Amphenol
Lead-acid or Li-Ion
48
50
50 (configurable)
≥50 (depending requirement)
3-stage adaptive with maintenance
60 (configurable)
Included (Li-Ion)
Integrated
Integrated
5000
5000
22.8
50/60Hz; 230Vac
45~55Hz/55~65Hz; 180~270Vac
<1.5%
0.8 leading~0.8 lagging
Single phase
10
2300
3500,10sec
97.6%
>97.0%
99.9%
94.5%
Integrated
Integrated
Integrated (optional)
Integrated
Integrated
347*432*175
17
Wall bracket
-25~60°C
0~95%
4000 m(> 3000m derating)
IP65
Natural convection
<25
LED light & APP
USB; RS485;CAN;WiFi
5
*: Do not exceed this voltage otherwise the inverter maybe damaged. At above 525V the inverter will issue the warning message “PV Over Voltage” and then protect itself by shutting down. **: Starting feed voltage [V] The minimum DC voltage from PV, to allow the inverter to support the load, battery or feeding the grid. ***: For lead-acid battery, default charge current is 0.15C, which can be configurable up to 0.5C and cannot exceed 50A; For Li-Ion battery, charge current follows the command of BMS which doesn't exceed 50A. ****: Under off-grid mode,the battery capacity should be more than 100 Ah.