Series Hybrid Inverter 3.0/3 6/5 - SegenSolar Data Sheet.pdf · EM Series Hybrid Inverter...

2
EM Series Hybrid Inverter 3.0/3.6/5.0kW Max. power output up to 5kW IP65 dust-proof and water-proof rating Easy remote monitoring via PCs, tablets and mobiles Fanless low-noise design Integrated charge controller and inverter Intelligent battery management function Grid-tied or grid-independent operation Compatible with both lead-acid and Li-ion batteries Increased performance and security How does it work? DC, current DC, no current AC, current AC, no current Mode1 ① First, Energy to load. ② Then charge battery. ③ Third, transfer energy to grid. PV energy produced is used for self-consumption. The excess energy is used to recharge the batteries, then any surplus is transferred to the grid If the grid fails, the system will automatically switch to back-up mode and use the battery stored energy When the PV system is not generating, and the battery is charged, the inverter will supply the load from the battery first, and if this is not sufficient, it will also draw power from the grid. Mode3 DC, current DC, no current AC, current AC, no current Mode2 DC, current DC, no current AC, current AC, no current www.goodwe.co.uk 0333 358 3184 [email protected]

Transcript of Series Hybrid Inverter 3.0/3 6/5 - SegenSolar Data Sheet.pdf · EM Series Hybrid Inverter...

Page 1: Series Hybrid Inverter 3.0/3 6/5 - SegenSolar Data Sheet.pdf · EM Series Hybrid Inverter 3.0/3.6/5.0kW Max. power output up to 5kW IP65 dust-proof and water-proof rating Easy remote

EM SeriesHybrid Inverter3.0/3.6/5.0kW

Max. power output up to 5kWIP65 dust-proof and water-proof rating Easy remote monitoring via PCs,tablets and mobilesFanless low-noise design

Integrated charge controller and inverterIntelligent battery management functionGrid-tied or grid-independent operationCompatible with both lead-acid and Li-ion batteriesIncreased performance and security

How does it work?

DC, currentDC, no currentAC, currentAC, no current

Mode�1

① First, Energy to load.

② Then charge battery.

③ Third, transfer energy to grid.

PV energy produced is used for self-consumption.

The excess energy is used to recharge the

batteries, then any surplus is transferred to the gridIf the grid fails, the system will automatically switch to back-up mode and use the battery stored energy

When the PV system is not generating, and the battery is charged, the inverter will supply the load from the battery first, and if this is not sufficient, it will also draw power from the grid.

Mode�3DC, currentDC, no currentAC, currentAC, no current

Mode�2DC, currentDC, no currentAC, currentAC, no current

■ www.goodwe.co.uk ■ 0333 358 3184 ■ [email protected]

Page 2: Series Hybrid Inverter 3.0/3 6/5 - SegenSolar Data Sheet.pdf · EM Series Hybrid Inverter 3.0/3.6/5.0kW Max. power output up to 5kW IP65 dust-proof and water-proof rating Easy remote

Technical Data GW3048-EM GW5048-EM

3900

3300

550

100~500

125

11

1

1

MC4/ Phoenix/ Amphenol

Lead-acid or Li-Ion

48

50

50 (configurable)

≥50 (depending requirement)

3-stage adaptive with maintenance

60 (configurable)

Included (Li-Ion)

Integrated

Integrated

3000

3000

13.6

50/60Hz; 230Vac

45~55Hz/55~65Hz; 180~270Vac

<1.5%

0.8 leading~0.8 lagging

Single phase

10

2300

3500,10sec

97.6%

>97.0%

99.9%

94.5%

Integrated

Integrated

Integrated (optional)

Integrated

Integrated

347*432*175

16

Wall bracket

-25~60°C

0~95%

4000 m(> 3000m derating)

IP65

Natural convection

<25

LED light & APP

USB; RS485;CAN;WiFi

5

4600

4000

550

100~500

125

11/11

2 (can parallel)

2

MC4/ Phoenix/ Amphenol

Lead-acid or Li-Ion

48

50

50 (configurable)

≥50 (depending requirement)

3-stage adaptive with maintenance

60 (configurable)

Included (Li-Ion)

Integrated

Integrated

3680

3680

16

50/60Hz; 230Vac

45~55Hz/55~65Hz; 180~270Vac

<1.5%

0.8 leading~0.8 lagging

Single phase

10

2300

3500,10sec

97.6%

>97.0%

99.9%

94.5%

Integrated

Integrated

Integrated (optional)

Integrated

Integrated

347*432*175

17

Wall bracket

-25~60°C

0~95%

4000 m(> 3000m derating)

IP65

Natural convection

<25

LED light & APP

USB; RS485;CAN;WiFi

5

VDE-AR-N 4105, AS4777.2, VDE0126-1-1, G83/G59, CEI 0-21

Solar

Max. allowed PV Power [W]

Nominal DC Power [W]

Max. DC voltage [V]*MPPT voltage range [V]

Starting feed voltage [V]**Max. DC current [A]

No. of DC connectors

No. of MPPTs

DC connector

Battery

Battery type

Norminal Voltage [V]

MAX Charge Current [A]***Max Discharge Current [A]

Battery capacity [Ah]****Charging curve

Max Charge voltage [V]

Battery temperature compensation

Battery voltage sense

Current shunt

AC Output Data (On-grid)

Norminal AC power [W]

Max. AC power [W]

Max. AC current [A]

Norminal AC output

AC output range

THDi

Power factor

Grid connection

AC Output Data (Back-up)

AC output (Back-up)

Max.AC current [A]

Norminal AC power [VA]

Peak power [VA]

Efficiency

Max. efficiency

Euro efficiency

MPPT adaptation efficiency

Max Battery efficiency

Protection

Residual current monitoring unit

Anti-islanding protection

DC switch (PV)

AC over current protection

Insulation monitoring

Certifications & Standards

Grid regulation

Safety

EMC

General Data

Dimensions (WxHxD) [mm]

Weight [kg]

Mounting

Ambient temperature range

Relative humidity

Max. operating altitude

Protection degree

Cooling

Noise emision [dB]

Display

Communication

Standard warranty [years]

GW3648-EM

230Vac ±2%, 50Hz (60Hz Optional)±0.2%,

THDv<3%(linear load),Single phase

IEC62109-1&-2,IEC62040-1

EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-3-11, EN61000-3-12

6500

5500

550

100~500

125

11/11

2 (can parallel)

2

MC4/ Phoenix/ Amphenol

Lead-acid or Li-Ion

48

50

50 (configurable)

≥50 (depending requirement)

3-stage adaptive with maintenance

60 (configurable)

Included (Li-Ion)

Integrated

Integrated

5000

5000

22.8

50/60Hz; 230Vac

45~55Hz/55~65Hz; 180~270Vac

<1.5%

0.8 leading~0.8 lagging

Single phase

10

2300

3500,10sec

97.6%

>97.0%

99.9%

94.5%

Integrated

Integrated

Integrated (optional)

Integrated

Integrated

347*432*175

17

Wall bracket

-25~60°C

0~95%

4000 m(> 3000m derating)

IP65

Natural convection

<25

LED light & APP

USB; RS485;CAN;WiFi

5

*: Do not exceed this voltage otherwise the inverter maybe damaged. At above 525V the inverter will issue the warning message “PV Over Voltage” and then protect itself by shutting down. **: Starting feed voltage [V] The minimum DC voltage from PV, to allow the inverter to support the load, battery or feeding the grid. ***: For lead-acid battery, default charge current is 0.15C, which can be configurable up to 0.5C and cannot exceed 50A; For Li-Ion battery, charge current follows the command of BMS which doesn't exceed 50A. ****: Under off-grid mode,the battery capacity should be more than 100 Ah.