Series 21- 10-VQ1000/2000 5 Port Solenoid Valve · 2018. 10. 12. · 10 21 Base Mounted Plug-in...

62
VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications P. 515 P. 517 P. 521 VQ2000 Sub-plate Single Unit VQ1000/2000 Semi-standard VQ1000/2000 Construction VQ1000/2000 Exploded View of Manifold VQ1000/2000 Manifold Optional Parts VQ1000/2000 Specific Product Precautions VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ2000 P. 560 P. 561 P. 564 P. 567 P. 571 P. 575 P. 523 P. 527 P. 531 P. 535 P. 539 P. 543 P. 547 P. 551 P. 557 F P J G T L S S M kit (D-sub connector) kit (Flat ribbon cable) kit (Flat ribbon cable) kit (Flat ribbon cable with terminal block) kit (Terminal block box) kit (Lead wire) kit (Serial transmission) EX510 kit (Serial transmission) EX120/123/124 kit (Circular connector) 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 10- 21- 5 Port Solenoid Valve 10- 21- Series VQ1000/2000 10-/21-VQ1000 10-/21-VQ2000 Manifold type Plug-in D-sub connector Flat ribbon cable Connector Serial Series Base Mounted 514 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R. Fittings & Tubing Air Cylinders Rotary Actuators

Transcript of Series 21- 10-VQ1000/2000 5 Port Solenoid Valve · 2018. 10. 12. · 10 21 Base Mounted Plug-in...

  • VQ1000 How to Order, Manifold OptionsVQ2000 How to Order, Manifold OptionsVQ1000/2000 Model, Standard/Manifold Specifications

    P. 515P. 517P. 521

    VQ2000 Sub-plate Single UnitVQ1000/2000 Semi-standardVQ1000/2000 ConstructionVQ1000/2000 Exploded View of Manifold VQ1000/2000 Manifold Optional PartsVQ1000/2000 Specific Product Precautions

    VQ1000/2000

    VQ1000/2000

    VQ1000/2000

    VQ1000/2000

    VQ1000/2000

    VQ1000/2000

    VQ1000/2000

    VQ1000/2000

    VQ2000

    P. 560P. 561P. 564P. 567P. 571P. 575

    P. 523

    P. 527

    P. 531

    P. 535

    P. 539

    P. 543

    P. 547

    P. 551

    P. 557

    F

    P

    J

    G

    T

    L

    S

    S

    M

    kit (D-sub connector)

    kit (Flat ribbon cable)

    kit (Flat ribbon cable)

    kit (Flat ribbon cable with terminal block)

    kit (Terminal block box)

    kit (Lead wire)

    kit (Serial transmission) EX510

    kit (Serial transmission) EX120/123/124

    kit (Circular connector)

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    10-21-

    5 Port Solenoid Valve10-21-Series VQ1000/2000

    10-/21-VQ1000

    10-/21-VQ2000

    Manifoldtype

    Plug-in

    D-subconnector

    Flat ribboncable Connector Serial

    Series

    Base Mounted

    514

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • Top entry

    Note 1)

    25P

    Side entry

    Top entry

    Note 1)

    26P

    Side entry

    Top entry

    20P

    Side entry

    20P Order separatelySI unit made by

    OMRON Corp.

    OptionManifoldPlug-in unit

    CE compliant

    VV5Q 1 1 08 C6

    1 station01

    1

    VQ10001—

    CE compliantNilQ

    Stations

    OptionNone

    200/220 VAC models (F/L kit only) With back pressure check valve

    DIN rail mountingWith DIN rail bracket (Without DIN rail)

    With ejector unitSpecial wiring spec. (Except double wiring)

    With name plateExternal pilot

    SymbolNil2

    B Note 2)

    DD0

    D Note 5)K Note 3)

    NR Note 4)

    With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingM5 threadMixed sizes and with port plugTop ported elbow with ø3.2 One-touch fittingTop ported elbow with ø4 One-touch fittingTop ported elbow with ø6 One-touch fitting

    Symbol Port size Symbol Port size

    C3C4C6M5

    CM Note 1)L3L4L6

    L5B3B4B6B5

    LM Note 1)MM Note 2)

    Series

    Top ported elbow M5 threadBottom ported elbow with ø3.2 One-touch fittingBottom ported elbow with ø4 One-touch fittingBottom ported elbow with ø6 One-touch fittingBottom ported elbow M5 threadElbow port, mixed sizesMixed size for different types of piping, option installed

    Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -BNR

    Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.

    Note 3) Specify the wiring specifications by means of the manifold specification sheet. (Except L kit)

    Note 4) Indicate “R” for the valve with external pilot.Note 5) : Station. Example: D08: The number of stations that

    may be displayed is longer than the manifold number of stations.Note 1) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.

    Note 2) When selecting the mixed size for different types of piping or dual flow fitting assembly, enter “MM” and give instructions on the manifold specification sheet.

    Note 3) Inch-size One-touch fittings are also available. Refer to page 563 for details.Note 4) M5 fittings for M5 thread are attached without being incorporated.

    U0U1U2U3

    S0S1S2S3

    Note 2)

    2 to 24stations

    P. 523

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Connector entry directionTop entry Side entry

    kit(D-sub connector)

    Fkit

    Fkit

    F

    U0U1U2U3

    U0U1U2U3

    S0S1S2S3

    S0S1S2S3

    Note 2)

    2 to 24stations

    Note 2)

    2 to 16stations

    P. 527 P. 531

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Connector entry direction Connector entry direction

    Top entry Top entrySide entry Side entry

    kit(Flat ribbon cable)

    kit(Flat ribbon cable 20P)

    Pkit

    Jkit

    Pkit

    Jkit

    P J

    P. 535

    kit(Flat ribbon cable with terminal block)

    G

    Note 2)

    2 to 16stations

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Gkit

    0123

    The voltage used for the valve is 24 VDC.

    Kit type/Electrical entry/Cable length

    Note 1) Besides the above, F/P kit with different number of pins are available. Refer to page 561 for details.Note 2) Refer to page 562 for details.

    Simple specials are available with SMC Simple Specials System.Refer to the WEB catalog for details on applicable models.

    U1F

    How to Order Manifold

    The number of max. stations differs from kit to kit.(Refer to the table below.)

    Note) For CE compliant models, DC-type only.

    Kit type

    Cylinder port

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    10

    [Option]

    Base MountedPlug-in Unit

    Note) For CE compliant models, DC-type only.

    10-21-Series VQ1000

    515

  • VQ1100-5

    VQ1100-5

    VQ1100-5

    VQ1100-5

    VQ1200-5

    VQ1200-5

    VQ1200-5

    VQ1200-5

    VVQ1000-10A-1

    BA

    BA

    BA

    3 m

    VQ1100-51

    VQ1100-51

    VQ1100-51

    VQ1100-51

    VQ1200-51

    VQ1200-51

    VQ1200-51

    VQ1200-51

    VVQ1000-10A-1

    Single solenoid (24 VDC)10-VQ1100-51 (4 sets)

    Double solenoid(24 VDC)

    10-VQ1200-51 (4 sets)

    Blanking plateVVQ1000-10A-1 (1 set)

    Cylinder portfitting size

    C6: With ø6 One-touchfitting

    Manifold base (9 stations)10-VV5Q11-09C6FU2

    F kit(D-sub connector)

    D-sub connectorcable assembly

    AXT100-DS25-030

    D side

    U side

    Station

    s

    3 2 1

    43 2

    1

    4

    3 21

    4

    [Option]

    Note) For CE compliant models, DC-type only.

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    Plug-in UnitBase Mounted VQ100010-21-

    How to Order Valve How to Order Manifold Assembly

    VQ 1 51 0 10

    VQ10001Series

    Metal sealRubber seal

    Seal01

    Manual override

    Example

    Nil: Non-lockingpush type(Tool required)

    B: Lockingtype(Tool required)

    D: Slide locking type (Manual)

    C: Locking type(Manual)

    The asterisk denotes the symbol for assembly.Prefix it to the part no. of the solenoid valve, etc.

    1 set (F kit 9-station manifold base part no.)4 sets (Single solenoid part no.)4 sets (Double solenoid part no.)1 set (Blanking plate part no.)

    10-VV5Q11-09C6FU2∗10-VQ1100-51∗10-VQ1200-51∗VVQ1000-10A-1

    100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz)

    24 VDC12 VDC

    Coil voltage12 Note)34 Note)56

    Actuation type

    1

    2

    3

    4

    5

    2-position single

    2-position double

    2-position double

    3-position closed center

    3-position exhaust center

    3-position pressure center

    Note 1) Refer to page 522 for power consumption of AC type.

    Note 2) Metal seal onlyNote 3) For external pilot and negative

    common specifications, refer to “Semi-standard” on pages 562 to 563.

    Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

    Light/surge voltage suppressor

    Note) Not applicable to the S kit.

    YesNone

    NilE Note)

    Specifications

    Standard

    High-speedresponse type

    Negativecommon

    Externalpilot

    High-pressure type(1.0 MPa)

    FunctionSymbol

    Nil

    B

    N Note 3)

    R Note 3)

    K Note 2)

    DC AC

    (0.4 W)Note 1)

    (0.95 W)

    (0.95 W)

    CautionUse the standard (DC) specification when continuously energizing for long periods of time.

    Note) 200 and 220 VAC: F/L kit only

    CE compliant—

    CE compliantNilQ

    Met

    alR

    ubbe

    r

    Specify the part numbers for valves and options together beneath the manifold base part number. Besides, when the arrangement will be complicated, specify them by means of the manifold specification sheet.

    ——

    ——

    CE compliant

    Note) For CE compliant models, DC-type only.

    P. 539

    kit(Terminal block box)

    T kit 0 Terminal block box 2 to 24 stations Note 2)

    T

    P. 543

    kit(Lead wire)

    Lkit

    012

    With cable (0.6 m)With cable (1.5 m)With cable (3 m)

    1 to 8stations

    L

    P. 551

    kit(Serial transmission)S

    Skit

    0HQR1R2V

    ZBZBN

    Without SI unit NKE Corp.: Fieldbus H SystemDeviceNet™OMRON Corp.: CompoBus/S (16 outputs)OMRON Corp.: CompoBus/S (8 outputs)CC-LinkCompoNet™ (Positive common)CompoNet™ (Negative common)

    Max.16 stations

    Max.16stations

    Max. 16stations

    Max. 8 stations

    Note 2)

    The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24 VDC. The dust proof SI unit is also available. Refer to page 551 for details.

    Note) Refer to “SI Unit Part No.” on page 551 when ordering the CE-compliant SI unit.

    516

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

    B

  • Note 1)

    25P

    Top entry

    Side entry

    Top entry

    Note 1)

    26P

    Side entry

    Top entry20P

    Side entry

    Note 2)

    2 to 24stations

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Mkit

    0123

    Option

    Kit type

    OptionSymbolNone

    200/220 VAC models (F/L kit only) With back pressure check valve

    DIN rail mountingWith DIN rail bracket (Without DIN rail)

    DIN rail length specifiedSpecial wiring spec. (Except double wiring)

    With name plateExternal pilot

    Nil2

    B Note 2)

    DD0

    D Note 5)K Note 3)

    NR Note 4)

    ManifoldPlug-in unit

    VV5Q 2 1 U1F08 C6

    1 station01

    1

    VQ20002

    StationsSymbol Port size Symbol Port size

    C4C6C8

    CM Note 1)

    L4L6

    L8B4B6B8

    LM Note 1)

    MM Note 2)

    Cylinder port

    Series

    With ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fittingMixed sizes and with port plugTop ported elbow with ø4 One-touch fittingTop ported elbow with ø6 One-touch fitting

    Top ported elbow with ø8 One-touch fittingBottom ported elbow with ø4 One-touch fittingBottom ported elbow with ø6 One-touch fittingBottom ported elbow with ø8 One-touch fittingElbow port, mixed sizesMixed size for different types of piping, option installed

    Skit

    Note 2)Max.16stations

    Max. 16 stations

    Max.16stations

    Max. 8 stations

    U0U1U2U3

    S0S1S2S3

    Note 2)

    2 to 24stations

    P. 523

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Connector entry directionTop entry Side entry

    Kit type/Electrical entry/Cable lengthkit(D-sub connector)

    Fkit

    Fkit

    F

    P. 539

    kit(Terminal blockbox)

    T kit

    Dust-tight/Water-jet-proof(IP65) compatible Note 3)

    Dust-tight/Water-jet-proof(IP65) compatible Note 3)

    0 Terminal block box 2 to 20 stations Note 2)

    T

    U0U1U2U3

    U0U1U2U3

    S0S1S2S3

    S0S1S2S3

    P. 543

    kit(Lead wire)

    Lkit

    012

    With cable (0.6 m)With cable (1.5 m)With cable (3 m)

    1 to 8stations

    L

    P. 551

    kit(Serial transmission)

    kit(Circular-connector)

    S M

    Note 2)

    2 to 24stations

    Note 2)

    2 to 16stations

    P. 527 P. 531

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Connector entry direction Connector entry directionTop entry Top entrySide entry Side entry

    kit(Flat ribbon cable)

    kit(Flat ribbon cable 20P)

    Pkit

    Jkit

    Pkit

    Jkit

    P J

    P. 535

    kit(Flat ribbon cable with terminal block)

    G

    Note 2)

    2 to 16stations

    With cable (1.5 m)With cable (3 m)With cable (5 m)

    Without cable

    Gkit

    U0U1U2U3

    Note 1) Besides the above, F/P kit with different number of pins are available. Refer to page 561 for details.

    Note 2) Refer to page 562 for details.

    Note 3) Refer to the pages on respective kits for IP65 type. (T/L/S/M kit)Note 4) Serial transmission system with IP65 enclosure applicable to input/output

    is also available. Refer to page 555 for details.

    Without SI unit

    NKE Corp.: Fieldbus H System

    DeviceNet™

    OMRON Corp.: CompoBus/S (16 outputs)

    OMRON Corp.: CompoBus/S (8 outputs)

    CC-Link

    P. 557

    Simple specials are available with SMC Simple Specials System.Refer to the WEB catalog for details on applicable models.

    The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24 VDC. The dusttight SI unit is available. Refer to page 551 for details. Dust-tight, Water-jet-proof (IP65) is available. Note 3)

    0

    H

    Q

    R1

    R2

    V

    Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -DNR

    Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.

    Note 3) Specify the wiring specifications by means of the manifold specification sheet. (Except L kit)

    Note 4) Indicate “R” for the valve with external pilot.Note 5) : Station. Example: D08: The number of

    stations that may be displayed is longer than the manifold number of stations.

    The maximum and minimum number of stations are varied depending on kit.(Refer to the below table.)

    CE compliant—

    CE compliantNilQ

    Note 1) Indicate “Mixed size and with port plug” by means of the manifold specification sheet.Note 2) When selecting the mixed size for different types of piping, dual flow fitting

    assembly, or double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.

    Note 3) Inch-size One-touch fittings are also available. Refer to page 563 for details.

    How to Order Manifold

    The voltageused for thevalve is 24 VDC.

    Note 4)

    Note) For CE compliant models, DC-type only.

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    10

    [Option]

    Base MountedPlug-in Unit

    Note) For CE compliant models, DC-type only.

    10-21-Series VQ2000

    Note) Refer to “SI Unit Part No.” on page 551 when ordering the CE-compliant SI unit.

    Dust-tight/Water-jet-proof(IP65) compatible Note 3)

    517C

  • 3 m

    VVQ2000-10A-1VQ2200-51

    VQ2200-51VQ2200-51

    VQ2200-51VQ2100-51

    VQ2100-51

    VQ2100-51

    Blanking plateVVQ2000-10A-1 (1 set)

    Double solenoid (24 VDC)10-VQ2200-51 (4 sets)

    Single solenoid (24 VDC)10-VQ2100-51 (3 sets)

    Cylinder port fitting sizeC8: With ø8 One-touch fitting

    Manifold base (8 stations)10-VV5Q21-08C8FU2

    F kit(D-sub connector)

    D-sub connectorcable assembly

    AXT100-DS25-030

    Station

    s

    D side

    U side

    How to Order Valve

    The asterisk denotes the symbol for assembly.Prefix it to the part no. of the solenoid valve, etc.

    1 set (F kit 8-station manifold base part no.)3 sets (Single solenoid part no.)4 sets (Double solenoid part no.)1 set (Blanking plate part no.)

    10-VV5Q21-08C8FU2∗10-VQ2100-51∗10-VQ2200-51∗VVQ2000-10A-1

    Specify the part numbers for valves and options together beneath the manifold base part number. Besides, when the arrangement will be complicated, specify them by means of the manifold specification sheet.

    How to Order Manifold Assembly

    Example

    Nil: Non-locking push type(Tool required)

    B: Push-locking slotted type(Tool required)

    C: Locking type (Manual)

    Manual override

    VQ 2 5 11 0 0

    VQ20002Series

    Coil voltage12 Note)34 Note)56

    100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz)

    24 VDC12 VDC

    Light/surge voltage suppressor

    YesNone

    NilE Note)

    SealMetal seal

    Rubber seal01

    Actuation type

    1

    2

    3

    4

    5

    2-position single

    2-position double

    2-position double

    3-position closed center

    3-position exhaust center

    3-position pressure center

    Specifications

    Standard

    High-speedresponse type

    Negativecommon

    Externalpilot

    High-pressure type(1.0 MPa)

    FunctionSymbol

    Nil

    B

    N Note 3)

    R Note 3)

    K Note 2)

    DC AC

    (0.4 W) Note 1)

    (0.95 W)

    (0.95 W)

    Note 1) For power consumption of AC type, refer to page 522.

    Note 2) Metal seal onlyNote 3) For external pilot and negative common

    specifications, refer to “Semi-standard” on pages 562 to 563.

    Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

    Note) For sub-plate single unit type, refer to page 560.

    Note) 200 and 220 VAC: F/L kit only

    Note) Not applicable to the S kit.

    CE compliant

    Enclosure

    —CE compliant

    NilQ

    Dust-tight/water-jet-proof type (IP65)

    Nil

    W Note)

    Note) T, L, S and M kits only

    Met

    alR

    ubbe

    r

    CautionUse the standard (DC) specification when continuously energizing for long periods of time.

    D: Slide locking type (Manual)

    ——

    ——

    CE compliant

    Note) For CE compliant models, DC-type only.

    Note) For CE compliant models, DC-type only.

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    [Option]

    Plug-in UnitBase Mounted VQ200010-21-

    518

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • 12

    34

    5

    98

    76

    C6 (SUP port)ø6 One-touch fitting

    C6 (EXH port)ø6 One-touch fitting

    C8 (SUP port)ø8 One-touch fitting

    C8 (EXH port)ø8 One-touch fitting

    VQ1000/200010-21-

    P. 571 to 57210- 21-VQ1000: Manifold Options

    P. 573 to 57410- 21-VQ2000: Manifold Options

    Blanking plate assemblyVVQ1000-10A-1

    SUP block plateVVQ1000-16A

    Individual SUP spacerVVQ1000-P-1-C6N7

    Individual EXH spacerVVQ1000-R-1-C6N7

    Back pressure check valve assembly [-B]VVQ1000-18A

    Name plate [-N]VVQ1000- -Station (1 to Max. stations)

    NNC

    C3, C4C6, M5N1, N3N7

    EXH block base assembly

    VVQ1000-19A- -FPL

    Blanking plugKQ2P-

    DIN rail mounting bracket [-D/-D0/-D]VVQ1000-57A

    Blanking plate assemblyVVQ2000-10A-1

    SUP block plateVVQ2000-16A

    Individual SUP spacerVVQ2000-P-1-C8N9

    Individual EXH spacerVVQ2000-R-1-C8N9

    EXH block plateVVQ2000-19A

    DIN rail mounting bracket[-D/-D0/-D]VVQ2000-57A

    Blanking plugKQ2P-

    Name plate [-N]VVQ2000-N-Station(1 to Max. stations)

    Back pressure check valve assembly [-B]VVQ2000-18A

    One set includes 2 pcs.

    One set includes 2 pcs.

    One set includes 2 pcs.

    519A

  • Model

    Series ModelActuation

    type

    Flow rate characteristics Note 1)

    Single

    Double

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Metal seal

    Rubber seal

    Response time (ms) Note 2)

    Standard:0.4 W

    15 or less

    20 or less

    13 or less

    20 or less

    26 or less

    33 or less

    26 or less

    33 or less

    26 or less

    33 or less

    29 or less

    31 or less

    20 or less

    26 or less

    38 or less

    44 or less

    38 or less

    44 or less

    38 or less

    44 or less

    0.18

    0.25

    0.18

    0.25

    0.18

    0.18

    0.18

    0.25

    0.18

    0.18

    0.60

    0.80

    0.60

    0.80

    0.46

    0.60

    0.60

    0.80

    0.46

    0.60

    0.25

    0.30

    0.25

    0.30

    0.25

    0.42

    0.25

    0.30

    0.25

    0.42

    0.15

    0.30

    0.15

    0.30

    0.18

    0.31

    0.15

    0.30

    0.18

    0.31

    0.72

    1.0

    0.72

    1.0

    0.72

    0.65

    0.72

    1.0

    0.72

    0.65

    2.6

    3.2

    2.6

    3.2

    2.0

    2.2

    2.6

    3.2

    2.0

    2.2

    0.16

    0.21

    0.16

    0.21

    0.16

    0.16

    0.16

    0.16

    0.16

    0.21

    0.46

    0.55

    0.46

    0.55

    0.46

    0.49

    0.46

    0.49

    0.57

    0.80

    0.15

    0.20

    0.15

    0.20

    0.15

    0.20

    0.15

    0.20

    0.15

    0.20

    0.15

    0.28

    0.15

    0.28

    0.15

    0.28

    0.15

    0.28

    0.17

    0.28

    0.70

    0.85

    0.70

    0.85

    0.68

    0.70

    0.68

    0.70

    0.70

    0.85

    2.0

    2.2

    2.0

    2.2

    2.0

    2.0

    2.0

    2.0

    2.4

    3.2

    High-speedresponse:

    0.95 W

    12 or less

    15 or less

    10 or less

    15 or less

    20 or less

    25 or less

    20 or less

    25 or less

    20 or less

    25 or less

    22 or less

    24 or less

    15 or less

    20 or less

    29 or less

    34 or less

    29 or less

    34 or less

    29 or less

    34 or less

    29 or less

    34 or less

    13 or less

    20 or less

    40 or less

    47 or less

    40 or less

    47 or less

    40 or less

    47 or less

    49 or less

    51 or less

    20 or less

    26 or less

    58 or less

    64 or less

    58 or less

    64 or less

    58 or less

    64 or less

    Weight(g)

    67

    77

    95

    105

    VQ1100

    VQ1101

    VQ1200

    VQ1201

    VQ1300

    VQ1301

    VQ1400

    VQ1401

    VQ1500

    VQ1501

    VQ2100

    VQ2101

    VQ2200

    VQ2201

    VQ2300

    VQ2301

    VQ2400

    VQ2401

    VQ2500

    VQ2501

    Closedcenter

    Exhaustcenter

    Pressurecenter

    Single

    Double

    Closedcenter

    Exhaustcenter

    Pressurecenter

    VQ1000

    VQ2000

    C [dm3/(s·bar)] C [dm3/(s·bar)]

    1 → 2/4 (P → A/B) 2/4 → 3/5 (A/B → R1/R2)

    b Cv b CvAC

    Note 1) The values are given for port size C6: (10-VQ1000), C8: (10-VQ2000) without back pressure check valve.Note 2) As per JIS B 8375-1981 (Supply pressure 0.5 MPa; with indicator light/surge voltage suppressor; clean air

    The response time is subject to the pressure and quality of the air.) The values at the time of ON are given for double types.

    2-po

    sitio

    n3-

    posi

    tion

    2-po

    sitio

    n3-

    posi

    tion

    10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-

    Base MountedPlug-in UnitSeries VQ1000/200010-21-

    521

  • Type of connection

    A, B port

    P port

    R port

    Type of connection

    A, B port

    P port

    R port

    VV5Q11 VV5Q2110-21-10-21-

    Plug-in UnitBase Mounted VQ1000/200010-21-

    Not required

    Push type, Locking type (Tool required, Manual) semi-standard

    150/30 m/s2

    Dust-protected; Dust-tight, Water-jet-proof (IP65) Note 4)

    12 , 24 VDC, 100, 110, 200, 220 VAC (50/60 Hz)

    ±10% of rated voltage

    Equivalent to Class B

    0.4 W DC (17 mA), 0.95 W DC (40 mA) Note 3)

    0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3)

    Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA)

    Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA)

    Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA)

    Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA)

    Standard Specifications

    Symbol

    Valve type

    Fluid

    Maximum operating pressure

    Minimumoperating pressure

    Ambient and fluid temperature

    Lubrication

    Manual override

    Impact/Vibration resistance Note 2)

    Enclosure

    Coil rated voltage

    Allowable voltage fluctuation

    Coil insulation type

    Metal seal

    Air, Inert gas

    0.7 MPa (High-pressure type: 1.0 MPa)

    0.1 MPa

    0.1 MPa

    0.1 MPa

    Rubber seal

    Air, Inert gas

    0.7 MPa

    0.15 MPa

    0.1 MPa

    0.2 MPa

    0.15 MPa

    24 VDC

    12 VDC

    100 VAC

    110 VAC

    200 VAC

    220 VAC

    Single

    Double

    3-position

    4-position

    –10 to 50°C Note 1)

    Power consumption(Current)

    Manifold Specifications

    Series

    F kit–D-sub connectorP kit–Flat ribbon cableJ kit–Flat ribbon cable (20P)G kit–Flat ribbon cable with terminal

    blockT kit–Terminal block boxL kit–Lead wireS kit–Serial transmission

    F kit–D-sub connectorP kit–Flat ribbon cable J kit–Flat ribbon cable (20P)G kit–Flat ribbon cable with terminal

    blockT kit–Terminal block boxL kit–Lead wire S kit–Serial transmissionM kit–Circular connector

    Base model

    VQ1000 VV5Q11-

    VQ2000 VV5Q21-

    Connection typePiping specifications

    Applicablestations

    Applicablesolenoid valve

    5-stationweight

    (g)Piping

    direction

    Side

    Port size Note 1)

    1(P), 3(R) 4(A), 2(B)

    C3 (ø3.2)

    C4(ø4)

    C6 (ø6)

    M5 (M5 thread)

    643(Single)

    754(Double,

    3-position)

    VQ100

    VQ101

    C8 (ø8)

    Option:Direct EXHoutlet with

    built-insilencer

    C10 (ø10)

    Option:Direct EXHoutlet with

    built-insilencer

    Side

    C4 (ø4)

    C6 (ø6)

    C8 (ø8)

    1076(Single)

    1119(Double,

    3-position)

    VQ200

    VQ201

    Note 1) Inch-size One-touch fittings are also available. Refer to page 563 for details.Note 2) Refer to page 562 for details.

    2-position single

    2-position double

    3-position closed center

    3-position exhaust center

    3-position pressure center

    2-position double

    Met

    alR

    ubbe

    r

    Val

    ve s

    pec

    ific

    atio

    ns

    Ele

    ctri

    cal s

    pec

    ific

    atio

    ns

    Note 1) Use dry air to prevent condensation when operating at low temperatures.Note 2) Impact resistance ······ No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition. (Default settings) Vibration resistance ··· No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings)Note 3) Value for high-speed response, high-voltage type (0.95 W)Note 4) Dust-tight, Water-jet-proof (IP65) is available on T/L/S/M kit of the VQ2000.

    Note 2)

    J/G/S kit2 to 16 stations

    L kit1 to 8 stations

    F/P kit2 to 24 stations

    T kit2 to 20 stations

    F/P/T kit2 to 24 stations

    J/G/S kit2 to 16 stations

    L kit1 to 8 stations

    10-21-

    10-21-

    522

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • Series 10- 21-VQ1000/2000Kit (D-sub connector)F

    10- 21- VV5Q11 10- 21- VV5Q21

    D-sub connector reduces installation labor for electrical connections.

    Using the D-sub connector (25P), (15P as semi-standard) conforming to MIL standard permits the use of commercial connectors and gives a wide interchangeability.

    Top or side receptacle position can be selected in accordance with the available mounting space.

    Maximum stations are 24.

    The D-sub connector cable assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”

    D-sub connector cable assembly Electrical characteristics

    Wire color by terminal no. ofD-sub connector cable assemblyTerminal no. Lead wire color Dot marking

    123456789

    10111213141516171819202122232425

    NoneNoneNoneNoneNoneNoneNoneWhiteBlackBlackRedRedRed

    BlackBlackWhiteNoneNoneBlackWhiteWhiteRedRed

    WhiteNone

    BlackBrownRed

    OrangeYellowPinkBlue

    PurpleGrayWhiteWhiteYellowOrangeYellowPinkBlue

    PurpleGray

    OrangeRed

    BrownPinkGrayBlackWhite

    ItemNoteAssembly part no.

    AXT100-DS25-015AXT100-DS25-030AXT100-DS25-050

    1.5 m3 m5 m

    Cablelength (L)

    Cable 25 coresx 24AWG

    Conductorresistance

    Ω/km, 20°C

    Voltage limitV, 1 minute, AC

    Insulationresistance

    MΩ/km, 20°C

    Property

    65 or less

    1000

    5 or more

    Note 1) Types with 15 pins are also available. Refer to page 561 for details.Note 2) Lengths other than the above are also available. Please contact SMC for details.

    Example of connector manufacturers• Fujitsu Limited• Japan Aviation Electronics Industry, Limited• J.S.T. Mfg. Co., Ltd.• HIROSE ELECTRIC CO., LTD.

    2 stations

    24 stations

    02

    24

    ManifoldPlug-in unit1

    VQ1000VQ2000

    12

    Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)

    0123

    Top entrySide entry

    US

    Option

    Connector entrydirection

    Port sizeWith ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting

    M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed

    VQ1000 VQ2000SymbolC3 Note 1)

    C4 Note 1)

    C6 Note 1)

    C8 Note 1)

    M5CM Note 2) Note 3)

    MM Note 4)

    Cylinder port

    Cable (Length)

    Series

    Stations

    Cable Assembly

    VV5Q 1 08 C6 U 11 F

    Note) Refer to page 562 for details.

    Manifold Specifications

    Applicablestations

    Port sizePipingdirection

    Side

    Side

    Piping specifications

    Max. 24 stations

    Max. 24 stations

    C3, C4, C6, M5

    C4, C6, C8

    C8

    C10

    4(A), 2(B)1(P), 3(R)

    Series

    10- 21- VQ100010- 21- VQ2000

    SymbolNil

    2

    B Note 2)

    DD0

    D Note 3)

    K Note 4)

    NR Note 5)

    OptionNone

    200/220 VAC models(F/L kit only)

    With back pressure check valveDIN rail mounting

    With DIN rail bracket (Without DIN rail)

    DIN rail length specified(: Stations 02 to 24)

    Special wiring specifications(Except double wiring)

    With name plateExternal pilot

    AXT100-DS25-015030050

    1644

    L

    8

    14 25

    1 13

    47.04

    55 2 x M2.6 x 0.45

    Socket side

    Terminal no.

    ≈ ø10

    Multi-core vinyl cable0.3 mm2 x 25 cores

    D-sub Connector (25 Pins)

    How to Order Manifold

    Note) The minimum bending radius of the D-sub connector cable is 20 mm.

    Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)

    Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or

    double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.

    Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.

    Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR

    Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.

    Note 3) The number of stations that may be displayed is longer than the manifold number of stations.

    Note 4) Specify the wiring specifications by means of the manifold specification sheet.

    Note 5) Indicate “R” for the valve with external pilot.

    ∗ For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308.

    ∗ Cannot be used for transfer wiring.

    CE compliant—

    CE compliantNilQ

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    [Option]

    Note) For CE compliant models, DC-type only.

    Note) For CE compliant models, DC-type only.

    523

  • 3 m

    VQ1100-51

    VQ1100-51

    VQ1100-51

    VQ1100-51

    VQ1200-51

    VQ1200-51

    VQ1200-51

    VQ1200-51

    VVQ1000-10A-1

    10- 21-VV5Q11

    10- 21-VV5Q21

    D side

    U side

    Station

    s

    D side

    U side

    Station

    s

    Station

    s

    D side

    U side

    Actuation type2-position single

    2-position double

    3-position closed center

    3-position exhaust center

    3-position pressure center

    12345

    VQ1000VQ2000

    12

    Series

    Metal sealRubber seal

    01

    Seal

    VQ 0 151 01

    Electrical Wiring Specifications

    As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to page 562 for details.

    Note) When using the negative common specifications, use valves for negative common. (Refer to page 562.)Refer to “Semi-standard” on page 562 for details.

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.A

    SOL.B

    SOL.B

    COM.

    1

    14

    2

    15

    3

    16

    4

    17

    5

    18

    6

    19

    7

    20

    8

    21

    9

    22

    10

    23

    11

    24

    12

    25

    13

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (–)

    Black

    Yellow

    Brown

    Pink

    Red

    Blue

    Orange

    Purple

    Yellow

    Gray

    Pink

    Orange

    Blue

    Red

    Purple

    Brown

    Gray

    Pink

    White

    Gray

    White

    Black

    Yellow

    White

    Orange

    None

    Black

    None

    Black

    None

    White

    None

    None

    None

    None

    None

    Black

    None

    White

    White

    White

    Black

    Red

    Black

    Red

    Red

    White

    Red

    None

    Red

    PolarityTerminal no. Lead wire color

    015030050

    Dot marking

    Station 1

    Station 2

    Station 3

    Station 4

    Station 5

    Station 6

    Station 7

    Station 8

    Station 9

    Station 10

    Station 11

    Station 12

    PositiveCOM spec.

    NegativeCOM spec.

    Note)

    Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)

    Manual overrideNilBCD

    100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz)

    24 VDC12 VDC

    Coil voltage123456

    Light/surge voltage suppressor

    YesNone

    NilE

    1 set–Manifold base part no.2 sets–Valve part no. (Stations 1 to 2)4 sets–Valve part no. (Stations 3 to 6)2 sets–Valve part no. (Stations 7 to 8)1 set–Blanking plate part no. (Station 9)

    Specify the part numbers for valves and options together beneath the manifold base part number.

    Prefix the asterisk to the part no. of the solenoid valve, etc.

    D-sub connector kit with cable (3 m)

    The total number of stations is tabulatedstarting from station one on the D-side.

    Specifications

    Standard

    High-speedresponse type

    Negativecommon

    Externalpilot

    High-pressure type(1.0 MPa)

    FunctionSymbol

    Nil

    B

    N Note 3)

    R Note 3)

    K Note 2)

    DC AC

    (0.4 W)

    (0.95 W)

    (0.95 W)

    D-sub connector assembly

    AXT100-DS25- Wire color

    How to Order Valve How to Order Manifold Assembly

    CautionUse the standard (DC) specification when continuously energizing for long periods of time.

    Note 1) Refer to page 522 for power consumption of AC type.

    Note 2) Metal seal onlyNote 3) For external pilot and negative

    common specifications, refer to “Semi-standard” on pages 562 to 563.

    Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

    10-VV5Q11-09C6FU2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51∗VVQ1000-10A-1

    Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.

    CE compliant—

    CE compliantNilQ

    Connectorterminal no.

    D-sub connector

    Note 1)

    ——

    ——

    CE compliant

    [Option]

    Note) For CE compliant models, DC-type only.

    Note) For CE compliant models, DC-type only.

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    Plug-in UnitBase Mounted VQ1000/200010-21-

    524

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • X

    R

    P

    X

    R

    PB A B A B AA A A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B A

    B

    A

    B

    A

    B

    A

    P = 10.5 31.4

    18.1

    (5.25)

    93.5

    <10

    0.4>

    63.5 40

    .5

    (12)

    (12)

    (7.5

    )

    (L4)(L3)L2

    L127P = 10.513.5 28

    1.5

    ≈ 2

    4.8

    66

    35 [25]

    61

    13

    18.7 7.

    7 40.

    7

    259.3

    (5.5

    )

    (35)

    C8 [3(R) EXH port]C8: ø8 One-touch fitting

    C8 [1(P) SUP port]C8: ø8 One-touch fitting

    C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread

    DIN rail clamp screw

    Applicable connector: D-sub connector (25P)(Complies with MIL-C-24308)

    C3, C4, C6, M5 [4(A), 2(B) port]

    M4 mounting hole

    D side U side

    Indicator light

    Manualoverride

    Stations 87654321 n

    [ ]: 25 pins (top entry)

    Series 10- 21-VQ1000/2000kit (D-sub connector)F

    10- 21-VV5Q11 < >: AC

    The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].

    2L nDimensions

    L1L2

    (L3)(L4)

    65.5

    83.5

    112.5

    123

    376

    94

    125

    135.5

    4 86.5

    104.5

    125

    135.5

    597

    115

    137.5

    148

    6107.5

    125.5

    150

    160.5

    7118

    136

    162.5

    173

    8128.5

    146.5

    175

    185.5

    9139

    157

    187.5

    198

    10149.5

    167.5

    187.5

    198

    11160

    178

    200

    210.5

    12170.5

    188.5

    212.5

    223

    13181

    199

    225

    235.5

    14191.5

    209.5

    237.5

    248

    15202

    220

    250

    260.5

    16212.5

    230.5

    250

    260.5

    17223

    241

    262.5

    273

    18233.5

    251.5

    275

    285.5

    19244

    262

    287.5

    298

    20254.5

    272.5

    300

    310.5

    21265

    283

    312.5

    323

    22275.5

    293.5

    325

    335.5

    23286

    304

    325

    335.5

    24296.5

    314.5

    337.5

    348

    Formula L1 = 10.5n + 44.5, L2 = 10.5n + 62.5 n: Station (Maximum 24 stations)

    With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7) L2 = 10.5n + 46.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.

    525

  • B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    EXHR

    X PXP

    REXH

    (L3) (5.25)

    73.5

    0.9

    P = 16

    (L4)

    6.5

    L24.5

    L1

    34.534.5

    1

    1

    39.5

    (7.5

    )

    (12)

    P = 16 41

    23

    10.6

    (35)

    (5.5

    )

    120

    <12

    6.9>

    80

    ≈ 4

    46.2

    (12) 13

    35

    24.5 9.

    5

    31.6

    49

    16

    C10 [1(P) SUP port]C10: ø10 One-touch fitting

    C10 [3(R) EXH port]C10: ø10 One-touch fitting

    C4, C6, C8 [4(A), 2(B) port]C4: ø4 One-touch fittingC6: ø6 One-touch fitting C8: ø8 One-touch fitting

    nStations 87654321

    DIN rail clamp screw

    Applicable connector: D-sub connector (25P)(Complies with MIL-C-24308)

    Indicator light

    Manualoverride

    4 x M5 mounting hole

    B

    A

    B

    A

    B

    A

    D side U side

    Plug-in UnitBase Mounted VQ1000/200010-21-

    10- 21-VV5Q21 < >: AC

    The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].

    2L nDimensions

    L1L2

    (L3)(L4)

    85

    105

    137.5

    148

    3101

    121

    150

    160.5

    4117

    137

    162.5

    173

    5133

    153

    187.5

    198

    6149

    169

    200

    210.5

    7165

    185

    212.5

    223

    8181

    201

    225

    235.5

    9197

    217

    250

    260.5

    10213

    233

    262.5

    273

    11229

    249

    275

    285.5

    12245

    265

    300

    310.5

    13261

    281

    312.5

    323

    14277

    297

    325

    335.5

    15293

    313

    337.5

    348

    16309

    329

    350

    360.5

    17325

    345

    375

    385.5

    18341

    361

    387.5

    398

    19357

    377

    400

    410.5

    20373

    393

    412.5

    423

    21389

    409

    437.5

    448

    22405

    425

    450

    460.5

    23421

    441

    462.5

    473

    24437

    457

    487.5

    498

    Formula L1 = 16n + 53, L2 = 16n + 73 n: Station (Maximum 24 stations)

    526

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • AXT100-FC26- to

    Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”

    Flat Ribbon Cable Connector AssemblyNoteAssembly part no.Cable length (L)

    AXT100-FC26-1AXT100-FC26-2AXT100-FC26-3

    1.5 m3 m5 m

    Cable 26 cores x 28AWG

    ∗ For other commercial connectors, use a 26 pins type with strain relief conforming to MIL-C-83503.

    ∗ Cannot be used for transfer wiring.

    Connector manufacturers’ example• HIROSE ELECTRIC CO., LTD.• 3M Japan Limited

    • Fujitsu Limited• Japan Aviation Electronics Industry, Limited

    • J.S.T. Mfg. Co., Ltd.• Oki Electric Cable Co., Ltd.

    2 stations

    24 stations

    02

    24

    ManifoldPlug-in unit1

    Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)

    0123

    Top entrySide entry

    US

    Connector entry direction

    Cable (Length)

    VQ1000VQ2000

    12

    Series

    Stations

    Cable Assembly

    VV5Q 1 08 C6 U 11 P

    Note) Refer to page 562 for details.

    Series 10- 21-VQ1000/2000kit (Flat ribbon cable)P

    10- 21- VV5Q11 10- 21- VV5Q21

    OptionSymbol Option

    NilB Note 2)

    DD0

    NR Note 5)

    K Note 4)

    D Note 3)

    NoneWith back pressure check valve

    DIN rail mountingWith DIN rail bracket (Without DIN rail)

    DIN rail length specified(: Stations 02 to 24)

    With name plateExternal pilot

    Special wiring specifications(Except double wiring)

    VQ1000 VQ2000SymbolC3 Note 1)

    C4 Note 1)

    C6 Note 1)

    C8 Note 1)

    M5CM Note 2) Note 3)

    MM Note 4)

    Cylinder portPort size

    With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting

    M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed

    10- 21- VV5Q11

    10- 21- VV5Q21

    The total number of stations is tabulated startingfrom one on the D-side.

    Term

    inal

    no.

    Red

    MIL flat ribbon cable connector reduces installation labor for electrical connection.

    Using the connector for flat ribbon cable (26P) conforming to MIL standard permits the use of commercial connectors and gives a wide interchangeability.

    Top or side receptacle position can be selected in accordance with the available mounting space.

    Maximum stations are 24.

    Flat Ribbon Cable (26 Pins)

    How to Order Manifold

    Note 1) Other than the above model, 10P, 16P, 20P are also available. Refer to page 561 for details.Note 2) Lengths other than the above are also available. Please contact SMC for details.

    Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR

    Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.

    Note 3) The number of stations that may be displayed is longer than the manifold number of stations.

    Note 4) Specify the wiring specifications by means of the manifold specification sheet.

    Note 5) Indicate “R” for the valve with external pilot.

    Manifold Specifications

    Applicablestations

    Port sizePipingdirection

    Side

    Side

    Piping specifications

    Max. 24 stations

    Max. 24 stations

    C3, C4, C6, M5

    C4, C6, C8

    C8

    C10

    4(A), 2(B)1(P), 3(R)

    Series

    10- 21- VQ100010- 21- VQ2000

    Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)

    Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly,

    or double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.

    Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.

    1

    3

    [Option]

    CE compliant—

    CE compliantNilQ

    Note) For CE compliant models, DC-type only.

    Note) For CE compliant models, DC-type only.

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    Station

    s

    D side

    U side

    Station

    s

    D side

    U side

    527

  • 3 m

    VQ1100-51

    VQ1100-51

    VQ1100-51

    VQ1100-51

    VQ1200-51

    VQ1200-51

    VQ1300-51

    VQ1300-51

    VVQ1000-10A-1

    D side

    U side

    Station

    s

    Actuation type2-position single

    2-position double

    3-position closed center

    3-position exhaust center

    3-position pressure center

    12345

    Metal sealRubber seal

    01

    Seal

    VQ 0 151 0

    VQ1000VQ2000

    12

    Series

    1

    Electrical Wiring Specifications

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.A

    SOL.B

    SOL.B

    COM.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (–)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (+)

    (–)

    (–)

    Terminal no. PolarityFlat ribbon cable connector

    Station 1

    Station 2

    Station 3

    Station 4

    Station 5

    Station 6

    Station 7

    Station 8

    Station 9

    Station 10

    Station 11

    Station 12

    PositiveCOM spec.Electrical wiring

    specifications

    NegativeCOM spec.

    Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)

    Manual overrideNilBCD

    100 VAC (50/60 Hz)110 VAC (50/60 Hz)

    24 VDC12 VDC

    Coil voltage1356

    Light/surge voltage suppressorYes

    NoneNilE

    COM.

    Prefix the asterisk to the part no. of the solenoid valve, etc.

    Flat ribbon cable kit with cable (3 m)

    As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to page 562 for details.

    Note) When using the negative common specifications, use valves for negative common. (Refer to page 562.)Refer to “Semi-standard” on page 562 for details.

    How to Order Valve How to Order Manifold Assembly

    Specifications

    Standard

    High-speedresponse type

    Negativecommon

    Externalpilot

    High-pressure type(1.0 MPa)

    FunctionSymbol

    Nil

    B

    N Note 3)

    R Note 3)

    K Note 2)

    DC AC

    (0.4 W)

    (0.95 W)

    (0.95 W)

    Specify the part numbers for valves and options together beneath the manifold base part number.

    Note 1) Refer to page 522 for power consumption of AC type.

    Note 2) Metal seal onlyNote 3) Refer to “Semi-standard” on pages 562

    to 563 for external pilot and negative common specifications.

    Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

    CautionUse the standard (DC) specification when continuously energizing for long periods of time.

    Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.

    CE compliant—

    CE compliantNilQ

    Connectorterminal no.

    Triangle markindicator position

    Note 1)

    1 set–Manifold base part no.2 sets–Valve part no. (Stations 1 to 2)4 sets–Valve part no. (Stations 3 to 6)2 sets–Valve part no. (Stations 7 to 8)1 set–Blanking plate part no. (Station 9)

    10-VV5Q11-09C6PU2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51∗VVQ1000-10A-1

    ——

    CE compliant

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    Note)

    [Option]

    Note) For CE compliant models, DC-type only.

    Note) For CE compliant models, DC-type only.

    Plug-in UnitBase Mounted VQ1000/200010-21-

    528

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    A A A B A B A B A B A

    X

    R

    P

    X

    R

    P

    52

    18.1

    P = 10.5 31.5

    (5.25)93

    .5 <

    100.

    4>

    (5.5

    )

    (35)

    40.5

    (12)

    (7.5

    )

    (12)

    23.5

    (L4)(L3)

    L2L1

    27P = 10.58.8 28

    1.5

    ≈ 2

    4.8

    66

    35

    63.5

    61.5

    13

    40.7

    259.3

    18.7 7.

    7

    C8 [3(R) EXH port]C8: ø8 One-touch fitting

    C8 [1(P) SUP port]C8: ø8 One-touch fitting

    C3, C4, C6, M5 [4(A), 2(B) port]

    C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread

    DIN rail clamp screw

    M4 mounting hole

    Indicator lightManualoverride

    Applicable connector: Flat ribbon cable connector (26P)(Complies with MIL-C-83503)

    D side U sideStations 87654321 n

    Series 10- 21-VQ1000/2000

    kit (Flat ribbon cable)P10- 21-VV5Q11 < >: AC

    The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].

    2L nDimensions

    L1L2

    (L3)(L4)

    65.5

    78.5

    112.5

    123

    376

    89

    125

    135.5

    4 86.5

    99.5

    125

    135.5

    597

    110

    137.5

    148

    6107.5

    120.5

    150

    160.5

    7118

    131

    162.5

    173

    8128.5

    141.5

    175

    185.5

    9139

    152

    187.5

    198

    10149.5

    162.5

    187.5

    198

    11160

    173

    200

    210.5

    12170.5

    183.5

    212.5

    223

    13181

    194

    225

    235.5

    14191.5

    204.5

    225

    235.5

    15202

    215

    237.5

    248

    16212.5

    225.5

    250

    260.5

    17223

    236

    262.5

    273

    18233.5

    246.5

    275

    285.5

    19244

    257

    287.5

    298

    20254.5

    267.5

    287.5

    298

    21265

    278

    300

    310.5

    22275.5

    288.5

    312.5

    323

    23286

    299

    325

    335.5

    24296.5

    309.5

    337.5

    348

    Formula L1 = 10.5n + 44.5, L2 = 10.5n + 57.5 n: Station (Maximum 24 stations)

    With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7) L2 = 10.5n + 41.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.

    529

  • (5.25)(L3)

    73.5 0.9

    L2L1 6.5

    34.5P = 1634.5

    1 1

    23.552

    (7.5

    )

    (12)

    P = 16 41

    23

    10.6

    (35)

    (5.5

    )

    120

    <12

    6.9>

    80

    ≈ 4

    46.2

    (12) 13

    (L4)73.5

    35

    24.5 9.

    5

    31.6

    49

    16Flat ribbon cable connector assembly (26P)AXT100-FC26-1: 1.5 mAXT100-FC26-2: 3 mAXT100-FC26-3: 5 m

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    EXHR

    XP

    EXHR

    PX

    C10 [3(R) EXH port]C10: ø10 One-touch fitting

    DIN rail clamp screw

    C10 [1(P) SUP port]C10: ø10 One-touch fitting

    C4, C6, C8 [4(A), 2(B) port]C4: ø4 One-touch fittingC6: ø6 One-touch fitting C8: ø8 One-touch fitting

    n87654321

    4 x M5 mounting hole

    Applicable connector: Flat ribbon cable connector (26P)(Complies with MIL-C-83503)

    Indicator light Manualoverride

    D side Stations U side

    < >: ACThe dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].

    Plug-in UnitBase Mounted VQ1000/200010-21-

    10- 21-VV5Q21

    2L nDimensions

    L1L2

    (L3)(L4)

    85

    100

    125

    135.5

    3101

    116

    150

    160.5

    4117

    132

    162.5

    173

    5133

    148

    175

    185.5

    6149

    164

    187.5

    198

    7165

    180

    212.5

    223

    8181

    196

    225

    235.5

    9197

    212

    237.5

    248

    10213

    228

    262.5

    273

    11229

    244

    275

    285.5

    12245

    260

    287.5

    298

    13261

    276

    300

    310.5

    14277

    292

    312.5

    323

    15293

    308

    337.5

    348

    16309

    324

    350

    360.5

    17325

    340

    362.5

    373

    18341

    356

    387.5

    398

    19357

    372

    400

    410.5

    20373

    388

    412.5

    423

    21389

    404

    425

    435.5

    22405

    420

    450

    460.5

    23421

    436

    462.5

    473

    24437

    452

    475

    485.5

    Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 24 stations)

    530

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • Flat Ribbon Cable (20 Pins)

    MIL flat ribbon cable connector reduces installation labor for electrical connection.

    Using the connector for flat ribbon cable connectors (20P) conforming to MIL standard permits the use of connector put on the market and gives a wide interchangeability.

    Top or side receptacle position can be selected in accordance with the available mounting space.

    Maximum stations are 16.

    AXT100-FC20-

    Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”

    Flat Ribbon Cable Connector AssemblyNoteAssembly part no.Cable length (L)

    AXT100-FC20-1AXT100-FC20-2AXT100-FC20-3

    1.5 m3 m5 m

    Cable 20 cores x 28AWG

    ∗ For other commercial connectors, use a 20 pins with strain relief conforming to MIL-C-83503.

    ∗ Cannot be used for transfer wiring.

    Example of connector manufacturers• HIROSE ELECTRIC CO., LTD.• 3M Japan Limited• Fujitsu Limited

    • Japan Aviation Electronics Industry, Limited• J.S.T. Mfg. Co., Ltd.• Oki Electric Cable Co., Ltd.

    2 stations

    16 stations

    02

    16

    ManifoldPlug-in unit1

    VQ1000VQ2000

    12

    Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)

    0123

    Top entrySide entry

    US

    Connector entry direction

    Cable (Length)

    Series

    Stations

    Cable Assembly

    VV5Q 1 08 C6 U 11 J

    Note) Refer to page 562 for details.

    Series 10- 21-VQ1000/2000kit (Flat ribbon cable)J

    10- 21-VV5Q11

    10- 21-VV5Q21

    Option

    VQ1000 VQ2000SymbolC3 Note 1)

    C4 Note 1)

    C6 Note 1)

    C8 Note 1)

    M5CM Note 2) Note 3)

    MM Note 4)

    Cylinder portPort size

    With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting

    M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed

    10- 21-VV5Q11

    10- 21-VV5Q21

    The total number of stations is tabulated starting from one on the D-side.

    Term

    inal

    no.

    Red

    Note) Lengths other than the above are also available. Please contact SMC for details.

    How to Order Manifold

    Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR

    Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.

    Note 3) The number of stations that may be displayed is longer than the manifold number of stations.

    Note 4) Specify the wiring specifications by means of the manifold specification sheet.

    Note 5) Indicate “R” for the valve with external pilot.

    Manifold Specifications

    Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)

    Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or

    double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.

    Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.

    CE compliant—

    CE compliantNilQ

    Applicablestations

    Port sizePipingdirection

    Side

    Side

    Piping specifications

    Max. 16 stations

    Max. 16 stations

    C3, C4, C6, M5

    C4, C6, C8

    C8

    C10

    4(A), 2(B)1(P), 3(R)

    Series

    10- 21-VQ100010- 21-VQ2000

    to1

    3

    [Option]

    Symbol Option

    NilB Note 2)

    DD0

    NR Note 5)

    K Note 4)

    D Note 3)

    NoneWith back pressure check valve

    DIN rail mountingWith DIN rail bracket (Without DIN rail)

    DIN rail length specified(: Stations 02 to 16)

    With name plateExternal pilot

    Special wiring specifications(Except double wiring)

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    D side

    U side

    Station

    s

    D side

    U side

    Station

    s

    531

  • 3 m

    Station

    s

    D side

    U side

    [Option]

    Plug-in UnitBase Mounted VQ1000/200010-21-

    Actuation type2-position single2-position double

    3-position closed center3-position exhaust center3-position pressure center

    12345

    VQ1000VQ2000

    12

    Series

    Metal sealRubber seal

    01

    Seal

    VQ 0 151 01

    Electrical Wiring Specifications

    Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)

    Manual overrideNilBCD

    24 VDC

    Coil voltage5

    Light/surge voltage suppressorYes

    NoneNilE

    Specify the part numbers for valves and options together beneath the manifold base part number.

    Prefix the asterisk to the part no. of the solenoid valve, etc.

    Flat ribbon cable kit with cable (3 m)

    Terminal no.

    Connectorterminal no.

    Flat ribbon cable connector

    Triangle markindicator position

    Polarity

    PositiveCOM spec.

    PositiveCOM spec.

    75312

    468

    1917151311910

    1214161820

    Station 2

    Station 3

    Station 4

    COM.

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    COM.

    20

    18

    16

    14

    12

    10

    8

    6

    19

    17

    15

    13

    11

    9

    7

    5

    4

    3

    2

    1

    Station 1

    Station 5 SOL.B

    Station 6 SOL.B

    Station 7 SOL.B

    Station 8 SOL.B

    SOL.A

    SOL.A

    SOL.A

    SOL.A

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (–)(–)

    (+)(+)

    (+)(+)

    (–)(–)

    How to Order Valve How to Order Manifold Assembly

    Specifications

    Standard

    High-speedresponse type

    Negativecommon

    Externalpilot

    High-pressure type(1.0 MPa)

    FunctionSymbol

    Nil

    B

    N Note 2)

    R Note 2)

    K Note 1)

    DC

    (0.4 W)

    (0.95 W)

    (0.95 W) Note 1) Metal seal onlyNote 2) Refer to “Semi-standard” on pages 562 to

    563 for external pilot and negative common specifications.

    Note 3) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

    1 set–Manifold base part no.2 sets–Valve part no. (Stations 1 to 2)4 sets–Valve part no. (Stations 3 to 6)1 set–Valve part no. (Station 7)1 set–Blanking plate part no. (Station 8)

    10-VV5Q11-08C6JU2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51∗VVQ1000-10A-1

    Note) When using the negative common specifications, use valves for negative common. (Refer to page 562,)Refer to “Semi-standard” on page 562 for details.

    Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.

    As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 8 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to “Semi-standard” on page 562 for details.

    CE compliant—

    CE compliantNilQ

    Note)

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    532

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    A

    A A A B A B A B A B A

    typ

    eX

    R

    P

    A

    B X

    R

    P

    P = 10.5 31.5

    18.1

    (5.25)40

    .5

    63.5

    93.5

    (5.5

    )

    (35)

    52

    (12)

    (7.5

    )

    (12)

    23.5

    (L4)(L3)

    L2L1

    27P = 10.58.8 28

    1.5

    ≈ 2

    4.8

    66

    35

    61.5

    13

    40.7

    259.3

    18.7 7.

    7

    C8 [3(R) EXH port]C8: ø8 One-touch fitting

    C8 [1(P) SUP port]C8: ø8 One-touch fitting

    C3, C4, C6, M5 [4(A), 2(B) port]

    C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread

    DIN rail clamp screw

    Stations 87654321 n

    4 x M4 mounting hole

    Indicator lightManualoverride

    Applicable connector: Flat ribbon cable connector (20P)(Complies with MIL-C-83503)

    D side U side

    Series 10- 21-VQ1000/2000kit (Flat ribbon cable)J

    10- 21-VV5Q11 The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].

    2L nDimensions

    L1L2

    (L3)(L4)

    65.5

    78.5

    112.5

    123

    376

    89

    125

    135.5

    4 86.5

    99.5

    125

    135.5

    597

    110

    137.5

    148

    6107.5

    120.5

    150

    160.5

    7118

    131

    162.5

    173

    8128.5

    141.5

    175

    185.5

    9139

    152

    187.5

    198

    10149.5

    162.5

    187.5

    198

    11160

    173

    200

    210.5

    12170.5

    183.5

    212.5

    223

    13181

    194

    225

    235.5

    14191.5

    204.5

    225

    235.5

    15202

    215

    237.5

    248

    16212.5

    225.5

    250

    260.5

    Formula L1 = 10.5n + 44.5, L2 = 10.5n + 57.5 n: Station (Maximum 16 stations)

    With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7) L2 = 10.5n + 41.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.

    533

  • B

    A

    B

    A

    B

    A

    B

    A

    X

    REXH

    P

    B

    A

    (L3) (5.25)

    73.50.9

    (L4)

    23.5 L2L1 6.5

    34.5P = 1634.5

    1 1

    52

    (7.5

    )

    (12)

    P = 16 41

    23

    10.6

    (35)

    (5.5

    )

    120

    80

    ≈ 4

    46.2

    (12) 13

    73.5

    35

    24.5 9.

    5

    31.6

    49

    16C10 [3(R) EXH port]

    C10: ø10 One-touch fitting

    DIN rail clamp screw

    C10 [1(P) SUP port]C10: ø10 One-touch fitting

    C4, C6, C8 [4(A), 2(B) port]C4: ø4 One-touch fittingC6: ø6 One-touch fitting C8: ø8 One-touch fitting

    nStations 87654321

    Indicator light Manualoverride

    4 x M5 mounting hole

    Applicable connector: Flat ribbon cable connector (20P)(Complies with MIL-C-83503)

    B

    A

    B

    A

    B

    A

    PC

    W ty

    pe

    EXHR

    PX

    D side U side

    Plug-in UnitBase Mounted VQ1000/200010-21-

    10- 21-VV5Q21 The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].

    2L nDimensions

    L1L2

    (L3)(L4)

    85

    100

    125

    135.5

    3101

    116

    150

    160.5

    4117

    132

    162.5

    173

    5133

    148

    175

    185.5

    6149

    164

    187.5

    198

    7165

    180

    212.5

    223

    8181

    196

    225

    235.5

    9197

    212

    237.5

    248

    10213

    228

    262.5

    273

    11229

    244

    275

    285.5

    12245

    260

    287.5

    298

    13261

    276

    300

    310.5

    14277

    292

    312.5

    323

    15293

    308

    337.5

    348

    16309

    324

    350

    360.5

    Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 16 stations)

    534

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • Terminal block for power supply equipped with a 20 pins flat ribbon cable connection for rationalized connection of valves.

    Solenoid valves and power supply can be connected by the same cable to a specific output unit that requires power supply from the output section to the internal circuit.

    Maximum stations are 16.

    AXT100-FC20- to1

    3

    Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”

    Term

    inal

    no.

    NoteAssembly part no.Cable length (L)1.5 m3 m5 m

    Cable 20 cores x 28AWG

    ∗ For other commercial connectors, use a 20 pins type with strain relief conforming to MIL-C-83503.

    ∗ Cannot be used for transfer wiring.

    Example of connector manufacturers• HIROSE ELECTRIC CO., LTD.• 3M Japan Limited

    • Japan Aviation Electronics Industry, Limited• J.S.T. Mfg. Co., Ltd.

    • Oki Electric Cable Co., Ltd.• Fujitsu Limited

    2 stations

    16 stations

    02

    16 Note)

    ManifoldPlug-in unit1

    VQ1000VQ2000

    12

    VQ1000VQ2000

    NilU

    Connector entry direction, Top entry

    Without cableCable length 1.5 m Cable length 3 mCable length 5 m

    0123

    Cable (Length)

    Series

    Stations

    Cable Assembly

    VV5Q 1 08 C61 G

    Series 10-

    21-VQ1000/2000kit (Flat ribbon cable with terminal block)G

    10- 21- VV5Q11 10- 21- VV5Q21

    The total number of stations is tabulated starting from station one on the D-side.

    Flat Ribbon Cable Connector Assembly

    AXT100-FC20-1AXT100-FC20-2AXT100-FC20-3

    Note) Refer to page 562 for details.

    Option

    VQ1000 VQ2000SymbolC3 Note 1)

    C4 Note 1)

    C6 Note 1)

    C8 Note 1)

    M5CM Note 2) Note 3)

    MM Note 4)

    Cylinder portPort size

    With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting

    M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed

    How to Order Manifold

    Flat Ribbon Cable (20 Pins)

    Note) Lengths other than the above are also available. Please contact SMC for details.

    Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR

    Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.

    Note 3) The number of stations that may be displayed is longer than the manifold number of stations.

    Note 4) Specify the wiring specifications by means of the manifold specification sheet.

    Note 5) Indicate “R” for the valve with external pilot.

    Manifold Specifications

    Applicablestations

    Port sizePipingdirection

    Side

    Side

    Piping specifications

    Max. 16 stations

    Max. 16 stations

    C3, C4, C6, M5

    C4, C6, C8

    C8

    C10

    4(A), 2(B)1(P), 3(R)

    Series

    10- 21- VQ100010- 21- VQ2000

    Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)

    Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double

    check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.

    CE compliant—

    CE compliantNilQ

    Red

    Symbol Option

    NilB Note 2)

    DD0

    NR Note 5)

    K Note 4)

    D Note 3)

    NoneWith back pressure check valve

    DIN rail mountingWith DIN rail bracket (Without DIN rail)

    DIN rail length specified(: Stations 02 to 16)

    With name plateExternal pilot

    Special wiring specifications(Except double wiring)

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle generation

    10

    21

    [Option]

    Power supply terminal block(Terminal screw M3)

    Indicator light

    SI unit made by OMRON Corp.Mountable for G71-OD16 (Order separately)

    10- 21- VV5Q11

    10- 21- VV5Q21

    Stations

    U side

    D side

    Station

    s

    D side

    D side

    535

  • 3 m

    VQ130

    0-51

    VQ130

    0-51

    VQ130

    0-51

    VQ120

    0-51

    VQ110

    0-51

    VQ110

    0-51

    VQ110

    0-51

    Stations

    U side

    D side

    [Option]

    Plug-in UnitBase Mounted VQ1000/200010-21-

    Actuation type2-position single2-position double

    3-position closed center3-position exhaust center3-position pressure center

    12345

    VQ1000VQ2000

    12

    SeriesMetal seal

    Rubber seal01

    Seal

    VQ 0 5 11 01

    Connector Assembly

    As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 8 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to page 562 for details.

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    SOL.A

    SOL.B

    20

    18

    16

    14

    12

    10

    8

    6

    19

    17

    15

    13

    11

    9

    7

    5

    3.4

    1.2

    –+

    Terminal no.Flat ribbon cable connector

    Electric circuit diagram (Below wiring is the case of all double solenoid connections.)

    Station 1

    24 VDC

    Station 2

    Station 3

    Station 4

    Station 5

    Connector terminal no.

    Station 6

    Station 7

    Station 8

    Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)

    Manual overrideNilBCD24 VDC

    Coil voltage5

    Light/surge voltage suppressorYes

    NoneNilE

    Specify the part numbers for valves and options together beneath the manifold base part number.

    Prefix the asterisk to the part no. of the solenoid valve, etc.

    Flat ribbon cable kit with terminal block with cable(3 m)

    How to Order Valve How to Order Manifold Assembly

    Specifications

    Standard

    High-speedresponse type

    Externalpilot

    High- pressure type(1.0 MPa)

    FunctionSymbol

    Nil

    B

    R Note 2)

    K Note 1)

    DC

    (0.4 W)

    (0.95 W)

    (0.95 W)

    Note 1) Metal seal onlyNote 2) Refer to “Semi-standard” on page 563 for

    external pilot specifications.Note 3) When two or more symbols are specified,

    indicate them alphabetically. Combination of [B] and [K] is not possible.

    Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.

    Triangle markindicator position

    CE compliant—

    CE compliantNilQ

    1 set–Manifold base part no.4 sets–Valve part no. (Stations 1 to 4)1 set–Valve part no. (Station 5)3 sets–Valve part no. (Stations 6 to 8)

    10-VV5Q11-08C6G2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51

    10

    Clean series

    Copper/Fluorine/Silicone free + Low particle

    generation

    10

    21

    536

    Air

    Pre

    par

    atio

    nE

    qu

    ipm

    ent

    Pre

    ssur

    e C

    ontr

    olE

    quip

    men

    tF

    low

    Co

    ntr

    ol

    Eq

    uip

    men

    tPr

    essu

    re S

    witc

    hes/

    Pres

    sure

    Sen

    sors

    Dir

    ecti

    on

    alC

    on

    tro

    l Val

    ves

    Air

    Gri

    pp

    ers

    Mo

    du

    lar

    F. R

    .Fi

    ttin

    gs &

    Tub

    ing

    Air

    Cyl

    ind

    ers

    Rot

    ary

    Act

    uato

    rs

  • A AB

    A

    B

    A

    B

    A

    AB

    A

    B AB

    A

    B AB

    A

    B AB

    A

    B AB

    A

    P = 10.5 31.5

    18.1

    63.4

    43.8

    63.5

    (12) 13

    (5.25)

    93.5

    (5.5

    )

    (35)

    40(7

    .5)

    (12)

    L2L1

    27P = 10.52913

    63.5

    61

    7.7

    13

    4.5

    (L4)(L3)

    18.7

    40.7

    25

    9.3

    66

    ≈ 2

    C8 [3(R) EXH port]C8: ø8 One-touch fitting

    C8 [1(P) SUP port]C8: ø8 One-touch fitting

    C3, C4, C6, M5 [4(A), 2(B) port]C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread

    R

    X

    P

    R

    X

    P

    Indicator light

    Power supply terminal block(Terminal screw M3)

    DIN rail clamp screw

    Stations 87654321 n

    4 x M4 mounting hole

    Indicator light Manualoverride

    Applicable connector: Flat ribbon cable connector (20P)(Complies with MIL-C-83503)

    Triangle mark indicator position

    D side U side

    Series 10- 21-VQ1000/2000kit (Flat ribbon cable with terminal block)G

    10- 21-VV5Q11 The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].

    2L nDimensions

    L1L2

    (L3)(L4)

    66.5

    84

    112.5

    123

    377

    94.5

    125

    135.5

    4 87.5

    105

    125

    135.5

    598

    115.5

    137.5

    148

    6108.5

    126

    150

    160.5

    7119

    136.5

    162.5

    173

    8129.5

    147

    175

    185.5

    9140

    157.5

    187.5

    198

    10150.5

    168

    187.5

    198

    11161

    178.5

    200

    210.5

    12171.5

    189

    212.5

    223

    13182

    199.5

    225

    235.5

    14192.5

    210

    237.5

    248

    15203

    220.5

    250

    260.5

    16213.5

    231

    262.5

    273

    Formula L1 = 10.5n + 45.5, L2 = 10.5n + 63 n: Station (Maximum 16 stations)

    With ejector unit: Formula L1 = 10.5n + 29.7 + (Number of ejector units x 26.7) L2 = 10.5n + 46.8 + (Number of ejector units x 26.7) L4 is L2 plus about 30.

    537

  • EXHR

    XP

    B

    A

    B

    A

    B