21-11051-lgb Doc 177 Filed 09/10/21 Entered 09/10/21 14:32 ...
Series 21- 10-VQ1000/2000 5 Port Solenoid Valve · 2018. 10. 12. · 10 21 Base Mounted Plug-in...
Transcript of Series 21- 10-VQ1000/2000 5 Port Solenoid Valve · 2018. 10. 12. · 10 21 Base Mounted Plug-in...
-
VQ1000 How to Order, Manifold OptionsVQ2000 How to Order, Manifold OptionsVQ1000/2000 Model, Standard/Manifold Specifications
P. 515P. 517P. 521
VQ2000 Sub-plate Single UnitVQ1000/2000 Semi-standardVQ1000/2000 ConstructionVQ1000/2000 Exploded View of Manifold VQ1000/2000 Manifold Optional PartsVQ1000/2000 Specific Product Precautions
VQ1000/2000
VQ1000/2000
VQ1000/2000
VQ1000/2000
VQ1000/2000
VQ1000/2000
VQ1000/2000
VQ1000/2000
VQ2000
P. 560P. 561P. 564P. 567P. 571P. 575
P. 523
P. 527
P. 531
P. 535
P. 539
P. 543
P. 547
P. 551
P. 557
F
P
J
G
T
L
S
S
M
kit (D-sub connector)
kit (Flat ribbon cable)
kit (Flat ribbon cable)
kit (Flat ribbon cable with terminal block)
kit (Terminal block box)
kit (Lead wire)
kit (Serial transmission) EX510
kit (Serial transmission) EX120/123/124
kit (Circular connector)
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
10-21-
5 Port Solenoid Valve10-21-Series VQ1000/2000
10-/21-VQ1000
10-/21-VQ2000
Manifoldtype
Plug-in
D-subconnector
Flat ribboncable Connector Serial
—
—
Series
Base Mounted
514
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
Top entry
Note 1)
25P
Side entry
Top entry
Note 1)
26P
Side entry
Top entry
20P
Side entry
20P Order separatelySI unit made by
OMRON Corp.
OptionManifoldPlug-in unit
CE compliant
VV5Q 1 1 08 C6
1 station01
1
VQ10001—
CE compliantNilQ
Stations
OptionNone
200/220 VAC models (F/L kit only) With back pressure check valve
DIN rail mountingWith DIN rail bracket (Without DIN rail)
With ejector unitSpecial wiring spec. (Except double wiring)
With name plateExternal pilot
SymbolNil2
B Note 2)
DD0
D Note 5)K Note 3)
NR Note 4)
With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingM5 threadMixed sizes and with port plugTop ported elbow with ø3.2 One-touch fittingTop ported elbow with ø4 One-touch fittingTop ported elbow with ø6 One-touch fitting
Symbol Port size Symbol Port size
C3C4C6M5
CM Note 1)L3L4L6
L5B3B4B6B5
LM Note 1)MM Note 2)
Series
Top ported elbow M5 threadBottom ported elbow with ø3.2 One-touch fittingBottom ported elbow with ø4 One-touch fittingBottom ported elbow with ø6 One-touch fittingBottom ported elbow M5 threadElbow port, mixed sizesMixed size for different types of piping, option installed
Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -BNR
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) Specify the wiring specifications by means of the manifold specification sheet. (Except L kit)
Note 4) Indicate “R” for the valve with external pilot.Note 5) : Station. Example: D08: The number of stations that
may be displayed is longer than the manifold number of stations.Note 1) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping or dual flow fitting assembly, enter “MM” and give instructions on the manifold specification sheet.
Note 3) Inch-size One-touch fittings are also available. Refer to page 563 for details.Note 4) M5 fittings for M5 thread are attached without being incorporated.
U0U1U2U3
S0S1S2S3
Note 2)
2 to 24stations
P. 523
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Connector entry directionTop entry Side entry
kit(D-sub connector)
Fkit
Fkit
F
U0U1U2U3
U0U1U2U3
S0S1S2S3
S0S1S2S3
Note 2)
2 to 24stations
Note 2)
2 to 16stations
P. 527 P. 531
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Connector entry direction Connector entry direction
Top entry Top entrySide entry Side entry
kit(Flat ribbon cable)
kit(Flat ribbon cable 20P)
Pkit
Jkit
Pkit
Jkit
P J
P. 535
kit(Flat ribbon cable with terminal block)
G
Note 2)
2 to 16stations
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Gkit
0123
The voltage used for the valve is 24 VDC.
Kit type/Electrical entry/Cable length
Note 1) Besides the above, F/P kit with different number of pins are available. Refer to page 561 for details.Note 2) Refer to page 562 for details.
Simple specials are available with SMC Simple Specials System.Refer to the WEB catalog for details on applicable models.
U1F
How to Order Manifold
The number of max. stations differs from kit to kit.(Refer to the table below.)
Note) For CE compliant models, DC-type only.
Kit type
Cylinder port
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
10
[Option]
Base MountedPlug-in Unit
Note) For CE compliant models, DC-type only.
10-21-Series VQ1000
515
-
VQ1100-5
VQ1100-5
VQ1100-5
VQ1100-5
VQ1200-5
VQ1200-5
VQ1200-5
VQ1200-5
VVQ1000-10A-1
BA
BA
BA
3 m
VQ1100-51
VQ1100-51
VQ1100-51
VQ1100-51
VQ1200-51
VQ1200-51
VQ1200-51
VQ1200-51
VVQ1000-10A-1
Single solenoid (24 VDC)10-VQ1100-51 (4 sets)
Double solenoid(24 VDC)
10-VQ1200-51 (4 sets)
Blanking plateVVQ1000-10A-1 (1 set)
Cylinder portfitting size
C6: With ø6 One-touchfitting
Manifold base (9 stations)10-VV5Q11-09C6FU2
F kit(D-sub connector)
D-sub connectorcable assembly
AXT100-DS25-030
D side
U side
Station
s
3 2 1
43 2
1
4
3 21
4
[Option]
Note) For CE compliant models, DC-type only.
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
Plug-in UnitBase Mounted VQ100010-21-
How to Order Valve How to Order Manifold Assembly
VQ 1 51 0 10
VQ10001Series
Metal sealRubber seal
Seal01
Manual override
Example
Nil: Non-lockingpush type(Tool required)
B: Lockingtype(Tool required)
D: Slide locking type (Manual)
C: Locking type(Manual)
The asterisk denotes the symbol for assembly.Prefix it to the part no. of the solenoid valve, etc.
1 set (F kit 9-station manifold base part no.)4 sets (Single solenoid part no.)4 sets (Double solenoid part no.)1 set (Blanking plate part no.)
10-VV5Q11-09C6FU2∗10-VQ1100-51∗10-VQ1200-51∗VVQ1000-10A-1
100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
Coil voltage12 Note)34 Note)56
Actuation type
1
2
3
4
5
2-position single
2-position double
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
Note 1) Refer to page 522 for power consumption of AC type.
Note 2) Metal seal onlyNote 3) For external pilot and negative
common specifications, refer to “Semi-standard” on pages 562 to 563.
Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.
Light/surge voltage suppressor
Note) Not applicable to the S kit.
YesNone
NilE Note)
Specifications
Standard
High-speedresponse type
Negativecommon
Externalpilot
High-pressure type(1.0 MPa)
FunctionSymbol
Nil
B
N Note 3)
R Note 3)
K Note 2)
DC AC
(0.4 W)Note 1)
(0.95 W)
(0.95 W)
CautionUse the standard (DC) specification when continuously energizing for long periods of time.
Note) 200 and 220 VAC: F/L kit only
CE compliant—
CE compliantNilQ
Met
alR
ubbe
r
Specify the part numbers for valves and options together beneath the manifold base part number. Besides, when the arrangement will be complicated, specify them by means of the manifold specification sheet.
——
——
CE compliant
Note) For CE compliant models, DC-type only.
P. 539
kit(Terminal block box)
T kit 0 Terminal block box 2 to 24 stations Note 2)
T
P. 543
kit(Lead wire)
Lkit
012
With cable (0.6 m)With cable (1.5 m)With cable (3 m)
1 to 8stations
L
P. 551
kit(Serial transmission)S
Skit
0HQR1R2V
ZBZBN
Without SI unit NKE Corp.: Fieldbus H SystemDeviceNet™OMRON Corp.: CompoBus/S (16 outputs)OMRON Corp.: CompoBus/S (8 outputs)CC-LinkCompoNet™ (Positive common)CompoNet™ (Negative common)
Max.16 stations
Max.16stations
Max. 16stations
Max. 8 stations
Note 2)
The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24 VDC. The dust proof SI unit is also available. Refer to page 551 for details.
Note) Refer to “SI Unit Part No.” on page 551 when ordering the CE-compliant SI unit.
516
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
B
-
Note 1)
25P
Top entry
Side entry
Top entry
Note 1)
26P
Side entry
Top entry20P
Side entry
Note 2)
2 to 24stations
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Mkit
0123
Option
Kit type
OptionSymbolNone
200/220 VAC models (F/L kit only) With back pressure check valve
DIN rail mountingWith DIN rail bracket (Without DIN rail)
DIN rail length specifiedSpecial wiring spec. (Except double wiring)
With name plateExternal pilot
Nil2
B Note 2)
DD0
D Note 5)K Note 3)
NR Note 4)
ManifoldPlug-in unit
VV5Q 2 1 U1F08 C6
1 station01
1
VQ20002
StationsSymbol Port size Symbol Port size
C4C6C8
CM Note 1)
L4L6
L8B4B6B8
LM Note 1)
MM Note 2)
Cylinder port
Series
With ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fittingMixed sizes and with port plugTop ported elbow with ø4 One-touch fittingTop ported elbow with ø6 One-touch fitting
Top ported elbow with ø8 One-touch fittingBottom ported elbow with ø4 One-touch fittingBottom ported elbow with ø6 One-touch fittingBottom ported elbow with ø8 One-touch fittingElbow port, mixed sizesMixed size for different types of piping, option installed
Skit
Note 2)Max.16stations
Max. 16 stations
Max.16stations
Max. 8 stations
U0U1U2U3
S0S1S2S3
Note 2)
2 to 24stations
P. 523
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Connector entry directionTop entry Side entry
Kit type/Electrical entry/Cable lengthkit(D-sub connector)
Fkit
Fkit
F
P. 539
kit(Terminal blockbox)
T kit
Dust-tight/Water-jet-proof(IP65) compatible Note 3)
Dust-tight/Water-jet-proof(IP65) compatible Note 3)
0 Terminal block box 2 to 20 stations Note 2)
T
U0U1U2U3
U0U1U2U3
S0S1S2S3
S0S1S2S3
P. 543
kit(Lead wire)
Lkit
012
With cable (0.6 m)With cable (1.5 m)With cable (3 m)
1 to 8stations
L
P. 551
kit(Serial transmission)
kit(Circular-connector)
S M
Note 2)
2 to 24stations
Note 2)
2 to 16stations
P. 527 P. 531
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Connector entry direction Connector entry directionTop entry Top entrySide entry Side entry
kit(Flat ribbon cable)
kit(Flat ribbon cable 20P)
Pkit
Jkit
Pkit
Jkit
P J
P. 535
kit(Flat ribbon cable with terminal block)
G
Note 2)
2 to 16stations
With cable (1.5 m)With cable (3 m)With cable (5 m)
Without cable
Gkit
U0U1U2U3
Note 1) Besides the above, F/P kit with different number of pins are available. Refer to page 561 for details.
Note 2) Refer to page 562 for details.
Note 3) Refer to the pages on respective kits for IP65 type. (T/L/S/M kit)Note 4) Serial transmission system with IP65 enclosure applicable to input/output
is also available. Refer to page 555 for details.
Without SI unit
NKE Corp.: Fieldbus H System
DeviceNet™
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-Link
P. 557
Simple specials are available with SMC Simple Specials System.Refer to the WEB catalog for details on applicable models.
The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24 VDC. The dusttight SI unit is available. Refer to page 551 for details. Dust-tight, Water-jet-proof (IP65) is available. Note 3)
0
H
Q
R1
R2
V
Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -DNR
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) Specify the wiring specifications by means of the manifold specification sheet. (Except L kit)
Note 4) Indicate “R” for the valve with external pilot.Note 5) : Station. Example: D08: The number of
stations that may be displayed is longer than the manifold number of stations.
The maximum and minimum number of stations are varied depending on kit.(Refer to the below table.)
CE compliant—
CE compliantNilQ
Note 1) Indicate “Mixed size and with port plug” by means of the manifold specification sheet.Note 2) When selecting the mixed size for different types of piping, dual flow fitting
assembly, or double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.
Note 3) Inch-size One-touch fittings are also available. Refer to page 563 for details.
How to Order Manifold
The voltageused for thevalve is 24 VDC.
Note 4)
Note) For CE compliant models, DC-type only.
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
10
[Option]
Base MountedPlug-in Unit
Note) For CE compliant models, DC-type only.
10-21-Series VQ2000
Note) Refer to “SI Unit Part No.” on page 551 when ordering the CE-compliant SI unit.
Dust-tight/Water-jet-proof(IP65) compatible Note 3)
517C
-
3 m
VVQ2000-10A-1VQ2200-51
VQ2200-51VQ2200-51
VQ2200-51VQ2100-51
VQ2100-51
VQ2100-51
Blanking plateVVQ2000-10A-1 (1 set)
Double solenoid (24 VDC)10-VQ2200-51 (4 sets)
Single solenoid (24 VDC)10-VQ2100-51 (3 sets)
Cylinder port fitting sizeC8: With ø8 One-touch fitting
Manifold base (8 stations)10-VV5Q21-08C8FU2
F kit(D-sub connector)
D-sub connectorcable assembly
AXT100-DS25-030
Station
s
D side
U side
How to Order Valve
The asterisk denotes the symbol for assembly.Prefix it to the part no. of the solenoid valve, etc.
1 set (F kit 8-station manifold base part no.)3 sets (Single solenoid part no.)4 sets (Double solenoid part no.)1 set (Blanking plate part no.)
10-VV5Q21-08C8FU2∗10-VQ2100-51∗10-VQ2200-51∗VVQ2000-10A-1
Specify the part numbers for valves and options together beneath the manifold base part number. Besides, when the arrangement will be complicated, specify them by means of the manifold specification sheet.
How to Order Manifold Assembly
Example
Nil: Non-locking push type(Tool required)
B: Push-locking slotted type(Tool required)
C: Locking type (Manual)
Manual override
VQ 2 5 11 0 0
VQ20002Series
Coil voltage12 Note)34 Note)56
100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
Light/surge voltage suppressor
YesNone
NilE Note)
SealMetal seal
Rubber seal01
Actuation type
1
2
3
4
5
2-position single
2-position double
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
Specifications
Standard
High-speedresponse type
Negativecommon
Externalpilot
High-pressure type(1.0 MPa)
FunctionSymbol
Nil
B
N Note 3)
R Note 3)
K Note 2)
DC AC
(0.4 W) Note 1)
(0.95 W)
(0.95 W)
Note 1) For power consumption of AC type, refer to page 522.
Note 2) Metal seal onlyNote 3) For external pilot and negative common
specifications, refer to “Semi-standard” on pages 562 to 563.
Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.
Note) For sub-plate single unit type, refer to page 560.
Note) 200 and 220 VAC: F/L kit only
Note) Not applicable to the S kit.
CE compliant
Enclosure
—CE compliant
NilQ
—
Dust-tight/water-jet-proof type (IP65)
Nil
W Note)
Note) T, L, S and M kits only
Met
alR
ubbe
r
CautionUse the standard (DC) specification when continuously energizing for long periods of time.
D: Slide locking type (Manual)
——
——
CE compliant
Note) For CE compliant models, DC-type only.
Note) For CE compliant models, DC-type only.
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
[Option]
Plug-in UnitBase Mounted VQ200010-21-
518
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
12
34
5
98
76
C6 (SUP port)ø6 One-touch fitting
C6 (EXH port)ø6 One-touch fitting
C8 (SUP port)ø8 One-touch fitting
C8 (EXH port)ø8 One-touch fitting
VQ1000/200010-21-
P. 571 to 57210- 21-VQ1000: Manifold Options
P. 573 to 57410- 21-VQ2000: Manifold Options
Blanking plate assemblyVVQ1000-10A-1
SUP block plateVVQ1000-16A
Individual SUP spacerVVQ1000-P-1-C6N7
Individual EXH spacerVVQ1000-R-1-C6N7
Back pressure check valve assembly [-B]VVQ1000-18A
Name plate [-N]VVQ1000- -Station (1 to Max. stations)
NNC
C3, C4C6, M5N1, N3N7
EXH block base assembly
VVQ1000-19A- -FPL
Blanking plugKQ2P-
DIN rail mounting bracket [-D/-D0/-D]VVQ1000-57A
Blanking plate assemblyVVQ2000-10A-1
SUP block plateVVQ2000-16A
Individual SUP spacerVVQ2000-P-1-C8N9
Individual EXH spacerVVQ2000-R-1-C8N9
EXH block plateVVQ2000-19A
DIN rail mounting bracket[-D/-D0/-D]VVQ2000-57A
Blanking plugKQ2P-
Name plate [-N]VVQ2000-N-Station(1 to Max. stations)
Back pressure check valve assembly [-B]VVQ2000-18A
One set includes 2 pcs.
One set includes 2 pcs.
One set includes 2 pcs.
519A
-
Model
Series ModelActuation
type
Flow rate characteristics Note 1)
Single
Double
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Response time (ms) Note 2)
Standard:0.4 W
15 or less
20 or less
13 or less
20 or less
26 or less
33 or less
26 or less
33 or less
26 or less
33 or less
29 or less
31 or less
20 or less
26 or less
38 or less
44 or less
38 or less
44 or less
38 or less
44 or less
0.18
0.25
0.18
0.25
0.18
0.18
0.18
0.25
0.18
0.18
0.60
0.80
0.60
0.80
0.46
0.60
0.60
0.80
0.46
0.60
0.25
0.30
0.25
0.30
0.25
0.42
0.25
0.30
0.25
0.42
0.15
0.30
0.15
0.30
0.18
0.31
0.15
0.30
0.18
0.31
0.72
1.0
0.72
1.0
0.72
0.65
0.72
1.0
0.72
0.65
2.6
3.2
2.6
3.2
2.0
2.2
2.6
3.2
2.0
2.2
0.16
0.21
0.16
0.21
0.16
0.16
0.16
0.16
0.16
0.21
0.46
0.55
0.46
0.55
0.46
0.49
0.46
0.49
0.57
0.80
0.15
0.20
0.15
0.20
0.15
0.20
0.15
0.20
0.15
0.20
0.15
0.28
0.15
0.28
0.15
0.28
0.15
0.28
0.17
0.28
0.70
0.85
0.70
0.85
0.68
0.70
0.68
0.70
0.70
0.85
2.0
2.2
2.0
2.2
2.0
2.0
2.0
2.0
2.4
3.2
High-speedresponse:
0.95 W
12 or less
15 or less
10 or less
15 or less
20 or less
25 or less
20 or less
25 or less
20 or less
25 or less
22 or less
24 or less
15 or less
20 or less
29 or less
34 or less
29 or less
34 or less
29 or less
34 or less
29 or less
34 or less
13 or less
20 or less
40 or less
47 or less
40 or less
47 or less
40 or less
47 or less
49 or less
51 or less
20 or less
26 or less
58 or less
64 or less
58 or less
64 or less
58 or less
64 or less
Weight(g)
67
77
95
105
VQ1100
VQ1101
VQ1200
VQ1201
VQ1300
VQ1301
VQ1400
VQ1401
VQ1500
VQ1501
VQ2100
VQ2101
VQ2200
VQ2201
VQ2300
VQ2301
VQ2400
VQ2401
VQ2500
VQ2501
Closedcenter
Exhaustcenter
Pressurecenter
Single
Double
Closedcenter
Exhaustcenter
Pressurecenter
VQ1000
VQ2000
C [dm3/(s·bar)] C [dm3/(s·bar)]
1 → 2/4 (P → A/B) 2/4 → 3/5 (A/B → R1/R2)
b Cv b CvAC
Note 1) The values are given for port size C6: (10-VQ1000), C8: (10-VQ2000) without back pressure check valve.Note 2) As per JIS B 8375-1981 (Supply pressure 0.5 MPa; with indicator light/surge voltage suppressor; clean air
The response time is subject to the pressure and quality of the air.) The values at the time of ON are given for double types.
2-po
sitio
n3-
posi
tion
2-po
sitio
n3-
posi
tion
10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-10-21-
Base MountedPlug-in UnitSeries VQ1000/200010-21-
521
-
Type of connection
A, B port
P port
R port
Type of connection
A, B port
P port
R port
VV5Q11 VV5Q2110-21-10-21-
Plug-in UnitBase Mounted VQ1000/200010-21-
Not required
Push type, Locking type (Tool required, Manual) semi-standard
150/30 m/s2
Dust-protected; Dust-tight, Water-jet-proof (IP65) Note 4)
12 , 24 VDC, 100, 110, 200, 220 VAC (50/60 Hz)
±10% of rated voltage
Equivalent to Class B
0.4 W DC (17 mA), 0.95 W DC (40 mA) Note 3)
0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3)
Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA)
Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA)
Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA)
Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA)
Standard Specifications
Symbol
Valve type
Fluid
Maximum operating pressure
Minimumoperating pressure
Ambient and fluid temperature
Lubrication
Manual override
Impact/Vibration resistance Note 2)
Enclosure
Coil rated voltage
Allowable voltage fluctuation
Coil insulation type
Metal seal
Air, Inert gas
0.7 MPa (High-pressure type: 1.0 MPa)
0.1 MPa
0.1 MPa
0.1 MPa
—
Rubber seal
Air, Inert gas
0.7 MPa
0.15 MPa
0.1 MPa
0.2 MPa
0.15 MPa
24 VDC
12 VDC
100 VAC
110 VAC
200 VAC
220 VAC
Single
Double
3-position
4-position
–10 to 50°C Note 1)
Power consumption(Current)
Manifold Specifications
Series
F kit–D-sub connectorP kit–Flat ribbon cableJ kit–Flat ribbon cable (20P)G kit–Flat ribbon cable with terminal
blockT kit–Terminal block boxL kit–Lead wireS kit–Serial transmission
F kit–D-sub connectorP kit–Flat ribbon cable J kit–Flat ribbon cable (20P)G kit–Flat ribbon cable with terminal
blockT kit–Terminal block boxL kit–Lead wire S kit–Serial transmissionM kit–Circular connector
Base model
VQ1000 VV5Q11-
VQ2000 VV5Q21-
Connection typePiping specifications
Applicablestations
Applicablesolenoid valve
5-stationweight
(g)Piping
direction
Side
Port size Note 1)
1(P), 3(R) 4(A), 2(B)
C3 (ø3.2)
C4(ø4)
C6 (ø6)
M5 (M5 thread)
643(Single)
754(Double,
3-position)
VQ100
VQ101
C8 (ø8)
Option:Direct EXHoutlet with
built-insilencer
C10 (ø10)
Option:Direct EXHoutlet with
built-insilencer
Side
C4 (ø4)
C6 (ø6)
C8 (ø8)
1076(Single)
1119(Double,
3-position)
VQ200
VQ201
Note 1) Inch-size One-touch fittings are also available. Refer to page 563 for details.Note 2) Refer to page 562 for details.
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
2-position double
Met
alR
ubbe
r
Val
ve s
pec
ific
atio
ns
Ele
ctri
cal s
pec
ific
atio
ns
Note 1) Use dry air to prevent condensation when operating at low temperatures.Note 2) Impact resistance ······ No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition. (Default settings) Vibration resistance ··· No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings)Note 3) Value for high-speed response, high-voltage type (0.95 W)Note 4) Dust-tight, Water-jet-proof (IP65) is available on T/L/S/M kit of the VQ2000.
Note 2)
J/G/S kit2 to 16 stations
L kit1 to 8 stations
F/P kit2 to 24 stations
T kit2 to 20 stations
F/P/T kit2 to 24 stations
J/G/S kit2 to 16 stations
L kit1 to 8 stations
10-21-
10-21-
522
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
Series 10- 21-VQ1000/2000Kit (D-sub connector)F
10- 21- VV5Q11 10- 21- VV5Q21
D-sub connector reduces installation labor for electrical connections.
Using the D-sub connector (25P), (15P as semi-standard) conforming to MIL standard permits the use of commercial connectors and gives a wide interchangeability.
Top or side receptacle position can be selected in accordance with the available mounting space.
Maximum stations are 24.
The D-sub connector cable assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”
D-sub connector cable assembly Electrical characteristics
Wire color by terminal no. ofD-sub connector cable assemblyTerminal no. Lead wire color Dot marking
123456789
10111213141516171819202122232425
NoneNoneNoneNoneNoneNoneNoneWhiteBlackBlackRedRedRed
BlackBlackWhiteNoneNoneBlackWhiteWhiteRedRed
WhiteNone
BlackBrownRed
OrangeYellowPinkBlue
PurpleGrayWhiteWhiteYellowOrangeYellowPinkBlue
PurpleGray
OrangeRed
BrownPinkGrayBlackWhite
ItemNoteAssembly part no.
AXT100-DS25-015AXT100-DS25-030AXT100-DS25-050
1.5 m3 m5 m
Cablelength (L)
Cable 25 coresx 24AWG
Conductorresistance
Ω/km, 20°C
Voltage limitV, 1 minute, AC
Insulationresistance
MΩ/km, 20°C
Property
65 or less
1000
5 or more
Note 1) Types with 15 pins are also available. Refer to page 561 for details.Note 2) Lengths other than the above are also available. Please contact SMC for details.
Example of connector manufacturers• Fujitsu Limited• Japan Aviation Electronics Industry, Limited• J.S.T. Mfg. Co., Ltd.• HIROSE ELECTRIC CO., LTD.
2 stations
24 stations
02
24
ManifoldPlug-in unit1
VQ1000VQ2000
12
Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)
0123
Top entrySide entry
US
Option
Connector entrydirection
Port sizeWith ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting
M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed
VQ1000 VQ2000SymbolC3 Note 1)
C4 Note 1)
C6 Note 1)
C8 Note 1)
M5CM Note 2) Note 3)
MM Note 4)
Cylinder port
Cable (Length)
Series
Stations
Cable Assembly
VV5Q 1 08 C6 U 11 F
Note) Refer to page 562 for details.
Manifold Specifications
Applicablestations
Port sizePipingdirection
Side
Side
Piping specifications
Max. 24 stations
Max. 24 stations
C3, C4, C6, M5
C4, C6, C8
C8
C10
4(A), 2(B)1(P), 3(R)
Series
10- 21- VQ100010- 21- VQ2000
SymbolNil
2
B Note 2)
DD0
D Note 3)
K Note 4)
NR Note 5)
OptionNone
200/220 VAC models(F/L kit only)
With back pressure check valveDIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified(: Stations 02 to 24)
Special wiring specifications(Except double wiring)
With name plateExternal pilot
AXT100-DS25-015030050
1644
L
8
14 25
1 13
47.04
55 2 x M2.6 x 0.45
Socket side
Terminal no.
≈ ø10
Multi-core vinyl cable0.3 mm2 x 25 cores
D-sub Connector (25 Pins)
How to Order Manifold
Note) The minimum bending radius of the D-sub connector cable is 20 mm.
Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)
Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the wiring specifications by means of the manifold specification sheet.
Note 5) Indicate “R” for the valve with external pilot.
∗ For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308.
∗ Cannot be used for transfer wiring.
CE compliant—
CE compliantNilQ
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
[Option]
Note) For CE compliant models, DC-type only.
Note) For CE compliant models, DC-type only.
523
-
3 m
VQ1100-51
VQ1100-51
VQ1100-51
VQ1100-51
VQ1200-51
VQ1200-51
VQ1200-51
VQ1200-51
VVQ1000-10A-1
10- 21-VV5Q11
10- 21-VV5Q21
D side
U side
Station
s
D side
U side
Station
s
Station
s
D side
U side
Actuation type2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
12345
VQ1000VQ2000
12
Series
Metal sealRubber seal
01
Seal
VQ 0 151 01
Electrical Wiring Specifications
As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to page 562 for details.
Note) When using the negative common specifications, use valves for negative common. (Refer to page 562.)Refer to “Semi-standard” on page 562 for details.
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.A
SOL.B
SOL.B
COM.
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(–)
Black
Yellow
Brown
Pink
Red
Blue
Orange
Purple
Yellow
Gray
Pink
Orange
Blue
Red
Purple
Brown
Gray
Pink
White
Gray
White
Black
Yellow
White
Orange
None
Black
None
Black
None
White
None
None
None
None
None
Black
None
White
White
White
Black
Red
Black
Red
Red
White
Red
None
Red
PolarityTerminal no. Lead wire color
015030050
Dot marking
Station 1
Station 2
Station 3
Station 4
Station 5
Station 6
Station 7
Station 8
Station 9
Station 10
Station 11
Station 12
PositiveCOM spec.
NegativeCOM spec.
Note)
Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)
Manual overrideNilBCD
100 VAC (50/60 Hz)200 VAC (50/60 Hz)110 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
Coil voltage123456
Light/surge voltage suppressor
YesNone
NilE
1 set–Manifold base part no.2 sets–Valve part no. (Stations 1 to 2)4 sets–Valve part no. (Stations 3 to 6)2 sets–Valve part no. (Stations 7 to 8)1 set–Blanking plate part no. (Station 9)
Specify the part numbers for valves and options together beneath the manifold base part number.
Prefix the asterisk to the part no. of the solenoid valve, etc.
D-sub connector kit with cable (3 m)
The total number of stations is tabulatedstarting from station one on the D-side.
Specifications
Standard
High-speedresponse type
Negativecommon
Externalpilot
High-pressure type(1.0 MPa)
FunctionSymbol
Nil
B
N Note 3)
R Note 3)
K Note 2)
DC AC
(0.4 W)
(0.95 W)
(0.95 W)
D-sub connector assembly
AXT100-DS25- Wire color
How to Order Valve How to Order Manifold Assembly
CautionUse the standard (DC) specification when continuously energizing for long periods of time.
Note 1) Refer to page 522 for power consumption of AC type.
Note 2) Metal seal onlyNote 3) For external pilot and negative
common specifications, refer to “Semi-standard” on pages 562 to 563.
Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.
10-VV5Q11-09C6FU2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51∗VVQ1000-10A-1
Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.
CE compliant—
CE compliantNilQ
Connectorterminal no.
D-sub connector
Note 1)
——
——
CE compliant
[Option]
Note) For CE compliant models, DC-type only.
Note) For CE compliant models, DC-type only.
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
Plug-in UnitBase Mounted VQ1000/200010-21-
524
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
X
R
P
X
R
PB A B A B AA A A
B
A
B
A
B
A
B
A
B
A
B A
B
A
B
A
B
A
P = 10.5 31.4
18.1
(5.25)
93.5
<10
0.4>
63.5 40
.5
(12)
(12)
(7.5
)
(L4)(L3)L2
L127P = 10.513.5 28
1.5
≈ 2
4.8
66
35 [25]
61
13
18.7 7.
7 40.
7
259.3
(5.5
)
(35)
C8 [3(R) EXH port]C8: ø8 One-touch fitting
C8 [1(P) SUP port]C8: ø8 One-touch fitting
C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread
DIN rail clamp screw
Applicable connector: D-sub connector (25P)(Complies with MIL-C-24308)
C3, C4, C6, M5 [4(A), 2(B) port]
M4 mounting hole
D side U side
Indicator light
Manualoverride
Stations 87654321 n
[ ]: 25 pins (top entry)
Series 10- 21-VQ1000/2000kit (D-sub connector)F
10- 21-VV5Q11 < >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].
2L nDimensions
L1L2
(L3)(L4)
65.5
83.5
112.5
123
376
94
125
135.5
4 86.5
104.5
125
135.5
597
115
137.5
148
6107.5
125.5
150
160.5
7118
136
162.5
173
8128.5
146.5
175
185.5
9139
157
187.5
198
10149.5
167.5
187.5
198
11160
178
200
210.5
12170.5
188.5
212.5
223
13181
199
225
235.5
14191.5
209.5
237.5
248
15202
220
250
260.5
16212.5
230.5
250
260.5
17223
241
262.5
273
18233.5
251.5
275
285.5
19244
262
287.5
298
20254.5
272.5
300
310.5
21265
283
312.5
323
22275.5
293.5
325
335.5
23286
304
325
335.5
24296.5
314.5
337.5
348
Formula L1 = 10.5n + 44.5, L2 = 10.5n + 62.5 n: Station (Maximum 24 stations)
With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7) L2 = 10.5n + 46.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.
525
-
B
A
B
A
B
A
B
A
B
A
EXHR
X PXP
REXH
(L3) (5.25)
73.5
0.9
P = 16
(L4)
6.5
L24.5
L1
34.534.5
1
1
39.5
(7.5
)
(12)
P = 16 41
23
10.6
(35)
(5.5
)
120
<12
6.9>
80
≈ 4
46.2
(12) 13
35
24.5 9.
5
31.6
49
16
C10 [1(P) SUP port]C10: ø10 One-touch fitting
C10 [3(R) EXH port]C10: ø10 One-touch fitting
C4, C6, C8 [4(A), 2(B) port]C4: ø4 One-touch fittingC6: ø6 One-touch fitting C8: ø8 One-touch fitting
nStations 87654321
DIN rail clamp screw
Applicable connector: D-sub connector (25P)(Complies with MIL-C-24308)
Indicator light
Manualoverride
4 x M5 mounting hole
B
A
B
A
B
A
D side U side
Plug-in UnitBase Mounted VQ1000/200010-21-
10- 21-VV5Q21 < >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].
2L nDimensions
L1L2
(L3)(L4)
85
105
137.5
148
3101
121
150
160.5
4117
137
162.5
173
5133
153
187.5
198
6149
169
200
210.5
7165
185
212.5
223
8181
201
225
235.5
9197
217
250
260.5
10213
233
262.5
273
11229
249
275
285.5
12245
265
300
310.5
13261
281
312.5
323
14277
297
325
335.5
15293
313
337.5
348
16309
329
350
360.5
17325
345
375
385.5
18341
361
387.5
398
19357
377
400
410.5
20373
393
412.5
423
21389
409
437.5
448
22405
425
450
460.5
23421
441
462.5
473
24437
457
487.5
498
Formula L1 = 16n + 53, L2 = 16n + 73 n: Station (Maximum 24 stations)
526
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
AXT100-FC26- to
Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”
Flat Ribbon Cable Connector AssemblyNoteAssembly part no.Cable length (L)
AXT100-FC26-1AXT100-FC26-2AXT100-FC26-3
1.5 m3 m5 m
Cable 26 cores x 28AWG
∗ For other commercial connectors, use a 26 pins type with strain relief conforming to MIL-C-83503.
∗ Cannot be used for transfer wiring.
Connector manufacturers’ example• HIROSE ELECTRIC CO., LTD.• 3M Japan Limited
• Fujitsu Limited• Japan Aviation Electronics Industry, Limited
• J.S.T. Mfg. Co., Ltd.• Oki Electric Cable Co., Ltd.
2 stations
24 stations
02
24
ManifoldPlug-in unit1
Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)
0123
Top entrySide entry
US
Connector entry direction
Cable (Length)
VQ1000VQ2000
12
Series
Stations
Cable Assembly
VV5Q 1 08 C6 U 11 P
Note) Refer to page 562 for details.
Series 10- 21-VQ1000/2000kit (Flat ribbon cable)P
10- 21- VV5Q11 10- 21- VV5Q21
OptionSymbol Option
NilB Note 2)
DD0
NR Note 5)
K Note 4)
D Note 3)
NoneWith back pressure check valve
DIN rail mountingWith DIN rail bracket (Without DIN rail)
DIN rail length specified(: Stations 02 to 24)
With name plateExternal pilot
Special wiring specifications(Except double wiring)
VQ1000 VQ2000SymbolC3 Note 1)
C4 Note 1)
C6 Note 1)
C8 Note 1)
M5CM Note 2) Note 3)
MM Note 4)
Cylinder portPort size
With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting
M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed
10- 21- VV5Q11
10- 21- VV5Q21
The total number of stations is tabulated startingfrom one on the D-side.
Term
inal
no.
Red
MIL flat ribbon cable connector reduces installation labor for electrical connection.
Using the connector for flat ribbon cable (26P) conforming to MIL standard permits the use of commercial connectors and gives a wide interchangeability.
Top or side receptacle position can be selected in accordance with the available mounting space.
Maximum stations are 24.
Flat Ribbon Cable (26 Pins)
How to Order Manifold
Note 1) Other than the above model, 10P, 16P, 20P are also available. Refer to page 561 for details.Note 2) Lengths other than the above are also available. Please contact SMC for details.
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the wiring specifications by means of the manifold specification sheet.
Note 5) Indicate “R” for the valve with external pilot.
Manifold Specifications
Applicablestations
Port sizePipingdirection
Side
Side
Piping specifications
Max. 24 stations
Max. 24 stations
C3, C4, C6, M5
C4, C6, C8
C8
C10
4(A), 2(B)1(P), 3(R)
Series
10- 21- VQ100010- 21- VQ2000
Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)
Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly,
or double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.
1
3
[Option]
CE compliant—
CE compliantNilQ
Note) For CE compliant models, DC-type only.
Note) For CE compliant models, DC-type only.
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
Station
s
D side
U side
Station
s
D side
U side
527
-
3 m
VQ1100-51
VQ1100-51
VQ1100-51
VQ1100-51
VQ1200-51
VQ1200-51
VQ1300-51
VQ1300-51
VVQ1000-10A-1
D side
U side
Station
s
Actuation type2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
12345
Metal sealRubber seal
01
Seal
VQ 0 151 0
VQ1000VQ2000
12
Series
1
Electrical Wiring Specifications
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.A
SOL.B
SOL.B
COM.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(–)
(–)
Terminal no. PolarityFlat ribbon cable connector
Station 1
Station 2
Station 3
Station 4
Station 5
Station 6
Station 7
Station 8
Station 9
Station 10
Station 11
Station 12
PositiveCOM spec.Electrical wiring
specifications
NegativeCOM spec.
Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)
Manual overrideNilBCD
100 VAC (50/60 Hz)110 VAC (50/60 Hz)
24 VDC12 VDC
Coil voltage1356
Light/surge voltage suppressorYes
NoneNilE
COM.
Prefix the asterisk to the part no. of the solenoid valve, etc.
Flat ribbon cable kit with cable (3 m)
As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to page 562 for details.
Note) When using the negative common specifications, use valves for negative common. (Refer to page 562.)Refer to “Semi-standard” on page 562 for details.
How to Order Valve How to Order Manifold Assembly
Specifications
Standard
High-speedresponse type
Negativecommon
Externalpilot
High-pressure type(1.0 MPa)
FunctionSymbol
Nil
B
N Note 3)
R Note 3)
K Note 2)
DC AC
(0.4 W)
(0.95 W)
(0.95 W)
Specify the part numbers for valves and options together beneath the manifold base part number.
Note 1) Refer to page 522 for power consumption of AC type.
Note 2) Metal seal onlyNote 3) Refer to “Semi-standard” on pages 562
to 563 for external pilot and negative common specifications.
Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.
CautionUse the standard (DC) specification when continuously energizing for long periods of time.
Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.
CE compliant—
CE compliantNilQ
Connectorterminal no.
Triangle markindicator position
Note 1)
1 set–Manifold base part no.2 sets–Valve part no. (Stations 1 to 2)4 sets–Valve part no. (Stations 3 to 6)2 sets–Valve part no. (Stations 7 to 8)1 set–Blanking plate part no. (Station 9)
10-VV5Q11-09C6PU2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51∗VVQ1000-10A-1
——
CE compliant
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
Note)
[Option]
Note) For CE compliant models, DC-type only.
Note) For CE compliant models, DC-type only.
Plug-in UnitBase Mounted VQ1000/200010-21-
528
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
A A A B A B A B A B A
X
R
P
X
R
P
52
18.1
P = 10.5 31.5
(5.25)93
.5 <
100.
4>
(5.5
)
(35)
40.5
(12)
(7.5
)
(12)
23.5
(L4)(L3)
L2L1
27P = 10.58.8 28
1.5
≈ 2
4.8
66
35
63.5
61.5
13
40.7
259.3
18.7 7.
7
C8 [3(R) EXH port]C8: ø8 One-touch fitting
C8 [1(P) SUP port]C8: ø8 One-touch fitting
C3, C4, C6, M5 [4(A), 2(B) port]
C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread
DIN rail clamp screw
M4 mounting hole
Indicator lightManualoverride
Applicable connector: Flat ribbon cable connector (26P)(Complies with MIL-C-83503)
D side U sideStations 87654321 n
Series 10- 21-VQ1000/2000
kit (Flat ribbon cable)P10- 21-VV5Q11 < >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].
2L nDimensions
L1L2
(L3)(L4)
65.5
78.5
112.5
123
376
89
125
135.5
4 86.5
99.5
125
135.5
597
110
137.5
148
6107.5
120.5
150
160.5
7118
131
162.5
173
8128.5
141.5
175
185.5
9139
152
187.5
198
10149.5
162.5
187.5
198
11160
173
200
210.5
12170.5
183.5
212.5
223
13181
194
225
235.5
14191.5
204.5
225
235.5
15202
215
237.5
248
16212.5
225.5
250
260.5
17223
236
262.5
273
18233.5
246.5
275
285.5
19244
257
287.5
298
20254.5
267.5
287.5
298
21265
278
300
310.5
22275.5
288.5
312.5
323
23286
299
325
335.5
24296.5
309.5
337.5
348
Formula L1 = 10.5n + 44.5, L2 = 10.5n + 57.5 n: Station (Maximum 24 stations)
With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7) L2 = 10.5n + 41.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.
529
-
(5.25)(L3)
73.5 0.9
L2L1 6.5
34.5P = 1634.5
1 1
23.552
(7.5
)
(12)
P = 16 41
23
10.6
(35)
(5.5
)
120
<12
6.9>
80
≈ 4
46.2
(12) 13
(L4)73.5
35
24.5 9.
5
31.6
49
16Flat ribbon cable connector assembly (26P)AXT100-FC26-1: 1.5 mAXT100-FC26-2: 3 mAXT100-FC26-3: 5 m
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
EXHR
XP
EXHR
PX
C10 [3(R) EXH port]C10: ø10 One-touch fitting
DIN rail clamp screw
C10 [1(P) SUP port]C10: ø10 One-touch fitting
C4, C6, C8 [4(A), 2(B) port]C4: ø4 One-touch fittingC6: ø6 One-touch fitting C8: ø8 One-touch fitting
n87654321
4 x M5 mounting hole
Applicable connector: Flat ribbon cable connector (26P)(Complies with MIL-C-83503)
Indicator light Manualoverride
D side Stations U side
< >: ACThe dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].
Plug-in UnitBase Mounted VQ1000/200010-21-
10- 21-VV5Q21
2L nDimensions
L1L2
(L3)(L4)
85
100
125
135.5
3101
116
150
160.5
4117
132
162.5
173
5133
148
175
185.5
6149
164
187.5
198
7165
180
212.5
223
8181
196
225
235.5
9197
212
237.5
248
10213
228
262.5
273
11229
244
275
285.5
12245
260
287.5
298
13261
276
300
310.5
14277
292
312.5
323
15293
308
337.5
348
16309
324
350
360.5
17325
340
362.5
373
18341
356
387.5
398
19357
372
400
410.5
20373
388
412.5
423
21389
404
425
435.5
22405
420
450
460.5
23421
436
462.5
473
24437
452
475
485.5
Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 24 stations)
530
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
Flat Ribbon Cable (20 Pins)
MIL flat ribbon cable connector reduces installation labor for electrical connection.
Using the connector for flat ribbon cable connectors (20P) conforming to MIL standard permits the use of connector put on the market and gives a wide interchangeability.
Top or side receptacle position can be selected in accordance with the available mounting space.
Maximum stations are 16.
AXT100-FC20-
Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”
Flat Ribbon Cable Connector AssemblyNoteAssembly part no.Cable length (L)
AXT100-FC20-1AXT100-FC20-2AXT100-FC20-3
1.5 m3 m5 m
Cable 20 cores x 28AWG
∗ For other commercial connectors, use a 20 pins with strain relief conforming to MIL-C-83503.
∗ Cannot be used for transfer wiring.
Example of connector manufacturers• HIROSE ELECTRIC CO., LTD.• 3M Japan Limited• Fujitsu Limited
• Japan Aviation Electronics Industry, Limited• J.S.T. Mfg. Co., Ltd.• Oki Electric Cable Co., Ltd.
2 stations
16 stations
02
16
ManifoldPlug-in unit1
VQ1000VQ2000
12
Without cableWith cable (1.5 m)With cable (3 m)With cable (5 m)
0123
Top entrySide entry
US
Connector entry direction
Cable (Length)
Series
Stations
Cable Assembly
VV5Q 1 08 C6 U 11 J
Note) Refer to page 562 for details.
Series 10- 21-VQ1000/2000kit (Flat ribbon cable)J
10- 21-VV5Q11
10- 21-VV5Q21
Option
VQ1000 VQ2000SymbolC3 Note 1)
C4 Note 1)
C6 Note 1)
C8 Note 1)
M5CM Note 2) Note 3)
MM Note 4)
Cylinder portPort size
With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting
M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed
10- 21-VV5Q11
10- 21-VV5Q21
The total number of stations is tabulated starting from one on the D-side.
Term
inal
no.
Red
Note) Lengths other than the above are also available. Please contact SMC for details.
How to Order Manifold
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the wiring specifications by means of the manifold specification sheet.
Note 5) Indicate “R” for the valve with external pilot.
Manifold Specifications
Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)
Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.
CE compliant—
CE compliantNilQ
Applicablestations
Port sizePipingdirection
Side
Side
Piping specifications
Max. 16 stations
Max. 16 stations
C3, C4, C6, M5
C4, C6, C8
C8
C10
4(A), 2(B)1(P), 3(R)
Series
10- 21-VQ100010- 21-VQ2000
to1
3
[Option]
Symbol Option
NilB Note 2)
DD0
NR Note 5)
K Note 4)
D Note 3)
NoneWith back pressure check valve
DIN rail mountingWith DIN rail bracket (Without DIN rail)
DIN rail length specified(: Stations 02 to 16)
With name plateExternal pilot
Special wiring specifications(Except double wiring)
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
D side
U side
Station
s
D side
U side
Station
s
531
-
3 m
Station
s
D side
U side
[Option]
Plug-in UnitBase Mounted VQ1000/200010-21-
Actuation type2-position single2-position double
3-position closed center3-position exhaust center3-position pressure center
12345
VQ1000VQ2000
12
Series
Metal sealRubber seal
01
Seal
VQ 0 151 01
Electrical Wiring Specifications
Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)
Manual overrideNilBCD
24 VDC
Coil voltage5
Light/surge voltage suppressorYes
NoneNilE
Specify the part numbers for valves and options together beneath the manifold base part number.
Prefix the asterisk to the part no. of the solenoid valve, etc.
Flat ribbon cable kit with cable (3 m)
Terminal no.
Connectorterminal no.
Flat ribbon cable connector
Triangle markindicator position
Polarity
PositiveCOM spec.
PositiveCOM spec.
75312
468
1917151311910
1214161820
Station 2
Station 3
Station 4
COM.
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
COM.
20
18
16
14
12
10
8
6
19
17
15
13
11
9
7
5
4
3
2
1
Station 1
Station 5 SOL.B
Station 6 SOL.B
Station 7 SOL.B
Station 8 SOL.B
SOL.A
SOL.A
SOL.A
SOL.A
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(–)(–)
(+)(+)
(+)(+)
(–)(–)
How to Order Valve How to Order Manifold Assembly
Specifications
Standard
High-speedresponse type
Negativecommon
Externalpilot
High-pressure type(1.0 MPa)
FunctionSymbol
Nil
B
N Note 2)
R Note 2)
K Note 1)
DC
(0.4 W)
(0.95 W)
(0.95 W) Note 1) Metal seal onlyNote 2) Refer to “Semi-standard” on pages 562 to
563 for external pilot and negative common specifications.
Note 3) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.
1 set–Manifold base part no.2 sets–Valve part no. (Stations 1 to 2)4 sets–Valve part no. (Stations 3 to 6)1 set–Valve part no. (Station 7)1 set–Blanking plate part no. (Station 8)
10-VV5Q11-08C6JU2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51∗VVQ1000-10A-1
Note) When using the negative common specifications, use valves for negative common. (Refer to page 562,)Refer to “Semi-standard” on page 562 for details.
Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.
As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 8 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to “Semi-standard” on page 562 for details.
CE compliant—
CE compliantNilQ
Note)
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
532
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
B
A
B
A
B
A
B
A
B
A
B
A
B
A
A A A B A B A B A B A
typ
eX
R
P
A
B X
R
P
P = 10.5 31.5
18.1
(5.25)40
.5
63.5
93.5
(5.5
)
(35)
52
(12)
(7.5
)
(12)
23.5
(L4)(L3)
L2L1
27P = 10.58.8 28
1.5
≈ 2
4.8
66
35
61.5
13
40.7
259.3
18.7 7.
7
C8 [3(R) EXH port]C8: ø8 One-touch fitting
C8 [1(P) SUP port]C8: ø8 One-touch fitting
C3, C4, C6, M5 [4(A), 2(B) port]
C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread
DIN rail clamp screw
Stations 87654321 n
4 x M4 mounting hole
Indicator lightManualoverride
Applicable connector: Flat ribbon cable connector (20P)(Complies with MIL-C-83503)
D side U side
Series 10- 21-VQ1000/2000kit (Flat ribbon cable)J
10- 21-VV5Q11 The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].
2L nDimensions
L1L2
(L3)(L4)
65.5
78.5
112.5
123
376
89
125
135.5
4 86.5
99.5
125
135.5
597
110
137.5
148
6107.5
120.5
150
160.5
7118
131
162.5
173
8128.5
141.5
175
185.5
9139
152
187.5
198
10149.5
162.5
187.5
198
11160
173
200
210.5
12170.5
183.5
212.5
223
13181
194
225
235.5
14191.5
204.5
225
235.5
15202
215
237.5
248
16212.5
225.5
250
260.5
Formula L1 = 10.5n + 44.5, L2 = 10.5n + 57.5 n: Station (Maximum 16 stations)
With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7) L2 = 10.5n + 41.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.
533
-
B
A
B
A
B
A
B
A
X
REXH
P
B
A
(L3) (5.25)
73.50.9
(L4)
23.5 L2L1 6.5
34.5P = 1634.5
1 1
52
(7.5
)
(12)
P = 16 41
23
10.6
(35)
(5.5
)
120
80
≈ 4
46.2
(12) 13
73.5
35
24.5 9.
5
31.6
49
16C10 [3(R) EXH port]
C10: ø10 One-touch fitting
DIN rail clamp screw
C10 [1(P) SUP port]C10: ø10 One-touch fitting
C4, C6, C8 [4(A), 2(B) port]C4: ø4 One-touch fittingC6: ø6 One-touch fitting C8: ø8 One-touch fitting
nStations 87654321
Indicator light Manualoverride
4 x M5 mounting hole
Applicable connector: Flat ribbon cable connector (20P)(Complies with MIL-C-83503)
B
A
B
A
B
A
PC
W ty
pe
EXHR
PX
D side U side
Plug-in UnitBase Mounted VQ1000/200010-21-
10- 21-VV5Q21 The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].
2L nDimensions
L1L2
(L3)(L4)
85
100
125
135.5
3101
116
150
160.5
4117
132
162.5
173
5133
148
175
185.5
6149
164
187.5
198
7165
180
212.5
223
8181
196
225
235.5
9197
212
237.5
248
10213
228
262.5
273
11229
244
275
285.5
12245
260
287.5
298
13261
276
300
310.5
14277
292
312.5
323
15293
308
337.5
348
16309
324
350
360.5
Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 16 stations)
534
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
Terminal block for power supply equipped with a 20 pins flat ribbon cable connection for rationalized connection of valves.
Solenoid valves and power supply can be connected by the same cable to a specific output unit that requires power supply from the output section to the internal circuit.
Maximum stations are 16.
AXT100-FC20- to1
3
Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold.”
Term
inal
no.
NoteAssembly part no.Cable length (L)1.5 m3 m5 m
Cable 20 cores x 28AWG
∗ For other commercial connectors, use a 20 pins type with strain relief conforming to MIL-C-83503.
∗ Cannot be used for transfer wiring.
Example of connector manufacturers• HIROSE ELECTRIC CO., LTD.• 3M Japan Limited
• Japan Aviation Electronics Industry, Limited• J.S.T. Mfg. Co., Ltd.
• Oki Electric Cable Co., Ltd.• Fujitsu Limited
2 stations
16 stations
02
16 Note)
ManifoldPlug-in unit1
VQ1000VQ2000
12
VQ1000VQ2000
NilU
Connector entry direction, Top entry
Without cableCable length 1.5 m Cable length 3 mCable length 5 m
0123
Cable (Length)
Series
Stations
Cable Assembly
VV5Q 1 08 C61 G
Series 10-
21-VQ1000/2000kit (Flat ribbon cable with terminal block)G
10- 21- VV5Q11 10- 21- VV5Q21
The total number of stations is tabulated starting from station one on the D-side.
Flat Ribbon Cable Connector Assembly
AXT100-FC20-1AXT100-FC20-2AXT100-FC20-3
Note) Refer to page 562 for details.
Option
VQ1000 VQ2000SymbolC3 Note 1)
C4 Note 1)
C6 Note 1)
C8 Note 1)
M5CM Note 2) Note 3)
MM Note 4)
Cylinder portPort size
With ø3.2 One-touch fittingWith ø4 One-touch fittingWith ø6 One-touch fittingWith ø8 One-touch fitting
M5 threadMixed sizes and with port plugMixed size for different types of piping, option installed
How to Order Manifold
Flat Ribbon Cable (20 Pins)
Note) Lengths other than the above are also available. Please contact SMC for details.
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BNR
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the wiring specifications by means of the manifold specification sheet.
Note 5) Indicate “R” for the valve with external pilot.
Manifold Specifications
Applicablestations
Port sizePipingdirection
Side
Side
Piping specifications
Max. 16 stations
Max. 16 stations
C3, C4, C6, M5
C4, C6, C8
C8
C10
4(A), 2(B)1(P), 3(R)
Series
10- 21- VQ100010- 21- VQ2000
Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.Example) B6 (Bottom ported elbow with ø6 One-touch fitting)
Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double
check block (direct mounting), enter “MM” and give instructions on the manifold specification sheet.Note 5) Inch-size One-touch fittings are available. Refer to “Semi-standard” on page 563 for details.
CE compliant—
CE compliantNilQ
Red
Symbol Option
NilB Note 2)
DD0
NR Note 5)
K Note 4)
D Note 3)
NoneWith back pressure check valve
DIN rail mountingWith DIN rail bracket (Without DIN rail)
DIN rail length specified(: Stations 02 to 16)
With name plateExternal pilot
Special wiring specifications(Except double wiring)
10
Clean series
Copper/Fluorine/Silicone free + Low particle generation
10
21
[Option]
Power supply terminal block(Terminal screw M3)
Indicator light
SI unit made by OMRON Corp.Mountable for G71-OD16 (Order separately)
10- 21- VV5Q11
10- 21- VV5Q21
Stations
U side
D side
Station
s
D side
D side
535
-
3 m
VQ130
0-51
VQ130
0-51
VQ130
0-51
VQ120
0-51
VQ110
0-51
VQ110
0-51
VQ110
0-51
Stations
U side
D side
[Option]
Plug-in UnitBase Mounted VQ1000/200010-21-
Actuation type2-position single2-position double
3-position closed center3-position exhaust center3-position pressure center
12345
VQ1000VQ2000
12
SeriesMetal seal
Rubber seal01
Seal
VQ 0 5 11 01
Connector Assembly
As the standard electrical wiring specifications, double wiring (connected to SOL.A and SOL.B) is adopted for the internal wiring of each station for 8 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. Refer to page 562 for details.
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
20
18
16
14
12
10
8
6
19
17
15
13
11
9
7
5
3.4
1.2
–+
Terminal no.Flat ribbon cable connector
Electric circuit diagram (Below wiring is the case of all double solenoid connections.)
Station 1
24 VDC
Station 2
Station 3
Station 4
Station 5
Connector terminal no.
Station 6
Station 7
Station 8
Non-locking push type (Tool required)Locking type (Tool required)Locking type (Manual)Slide locking type (Manual)
Manual overrideNilBCD24 VDC
Coil voltage5
Light/surge voltage suppressorYes
NoneNilE
Specify the part numbers for valves and options together beneath the manifold base part number.
Prefix the asterisk to the part no. of the solenoid valve, etc.
Flat ribbon cable kit with terminal block with cable(3 m)
How to Order Valve How to Order Manifold Assembly
Specifications
Standard
High-speedresponse type
Externalpilot
High- pressure type(1.0 MPa)
FunctionSymbol
Nil
B
R Note 2)
K Note 1)
DC
(0.4 W)
(0.95 W)
(0.95 W)
Note 1) Metal seal onlyNote 2) Refer to “Semi-standard” on page 563 for
external pilot specifications.Note 3) When two or more symbols are specified,
indicate them alphabetically. Combination of [B] and [K] is not possible.
Write sequentially from the 1st station on the D-side.When part no. written collectively are complicated, specify them by means of the manifold specification sheet.
Triangle markindicator position
CE compliant—
CE compliantNilQ
1 set–Manifold base part no.4 sets–Valve part no. (Stations 1 to 4)1 set–Valve part no. (Station 5)3 sets–Valve part no. (Stations 6 to 8)
10-VV5Q11-08C6G2∗10-VQ1100-51∗10-VQ1200-51∗10-VQ1300-51
10
Clean series
Copper/Fluorine/Silicone free + Low particle
generation
10
21
536
Air
Pre
par
atio
nE
qu
ipm
ent
Pre
ssur
e C
ontr
olE
quip
men
tF
low
Co
ntr
ol
Eq
uip
men
tPr
essu
re S
witc
hes/
Pres
sure
Sen
sors
Dir
ecti
on
alC
on
tro
l Val
ves
Air
Gri
pp
ers
Mo
du
lar
F. R
.Fi
ttin
gs &
Tub
ing
Air
Cyl
ind
ers
Rot
ary
Act
uato
rs
-
A AB
A
B
A
B
A
AB
A
B AB
A
B AB
A
B AB
A
B AB
A
P = 10.5 31.5
18.1
63.4
43.8
63.5
(12) 13
(5.25)
93.5
(5.5
)
(35)
40(7
.5)
(12)
L2L1
27P = 10.52913
63.5
61
7.7
13
4.5
(L4)(L3)
18.7
40.7
25
9.3
66
≈ 2
C8 [3(R) EXH port]C8: ø8 One-touch fitting
C8 [1(P) SUP port]C8: ø8 One-touch fitting
C3, C4, C6, M5 [4(A), 2(B) port]C3: ø3.2 One-touch fitting C4: ø4 One-touch fittingC6: ø6 One-touch fitting M5: M5 thread
R
X
P
R
X
P
Indicator light
Power supply terminal block(Terminal screw M3)
DIN rail clamp screw
Stations 87654321 n
4 x M4 mounting hole
Indicator light Manualoverride
Applicable connector: Flat ribbon cable connector (20P)(Complies with MIL-C-83503)
Triangle mark indicator position
D side U side
Series 10- 21-VQ1000/2000kit (Flat ribbon cable with terminal block)G
10- 21-VV5Q11 The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].
2L nDimensions
L1L2
(L3)(L4)
66.5
84
112.5
123
377
94.5
125
135.5
4 87.5
105
125
135.5
598
115.5
137.5
148
6108.5
126
150
160.5
7119
136.5
162.5
173
8129.5
147
175
185.5
9140
157.5
187.5
198
10150.5
168
187.5
198
11161
178.5
200
210.5
12171.5
189
212.5
223
13182
199.5
225
235.5
14192.5
210
237.5
248
15203
220.5
250
260.5
16213.5
231
262.5
273
Formula L1 = 10.5n + 45.5, L2 = 10.5n + 63 n: Station (Maximum 16 stations)
With ejector unit: Formula L1 = 10.5n + 29.7 + (Number of ejector units x 26.7) L2 = 10.5n + 46.8 + (Number of ejector units x 26.7) L4 is L2 plus about 30.
537
-
EXHR
XP
B
A
B
A
B