Serial No: Design Code: Manufactured by: Xina Solar One · NPT 3000# NPT RF 300# 5.000 N-m 4.250...
-
Upload
hoangkhuong -
Category
Documents
-
view
218 -
download
0
Transcript of Serial No: Design Code: Manufactured by: Xina Solar One · NPT 3000# NPT RF 300# 5.000 N-m 4.250...
ø406.4
31
25
200
InletSERVICE
N4
N2N1
ITEM
N3
RF Outlet
10"1
RATINGQTY. NPS
TYPE
NOZZLES11 1"
1 10"
Drain300# Vent
Longitudinal moment, Ml
Longitudinal load, Vl
Circunferential load, VcCircunferential moment, Mc
Torsional moment, Mt
LOADS AND MOMENTS SHELL-NOZZLES
LOADS AND MOMENTS SHELL-NOZZLES
LOADS AND MOMENTS SHELL-NOZZLES
LOADS AND MOMENTS SHELL-NOZZLES
LOADS AND MOMENTS SHELL-NOZZLES
LOADS AND MOMENTS SHELL-NOZZLES
LOADS AND MOMENTS SHELL-NOZZLES
NOZZLERadial load, P
INLET N1
MtMtMtMtMtMtMtMl
Vc P
3000# NPT3000# NPT
RF300#
5.000 N-m 4.250 N-m
11.000 N
8.000 N 2.800 N·m
7.000 N
Manufactured by:Xina Solar One
1"
and Safety Act. 1993 (Act No. 85 of 1993)Serial No:Design Code:
Design Data
Design Code
Design Pressure
FluidASME B&PVC Sec. VIII Div.1 Ed. 2013
2
11
N3
8
N2
7
12
NORTEMECÁNICA designs and manufactures filtering equipment and filtration systems for both liquid and gas.
Our manufacturing programme includes the following different types:
- Basket strainers - Cartridge filters - Bag filters - Self-cleaning strainers - Tee strainers - Y strainers - Temporary conical strainers - Sand filters - Activated-carbon filters
Área Industrial de Tabaza I, parcela E-5, E-33469 Carreño, Asturias Tel. +34 985 579 857
www.nortemecanica.es
Manufacturing Programme
200
2
11Filtration forPower Stations andPetrochemical Plants
780
Power Stations andPetrochemical Plants
270
780
1050
6
2
1
"A""A""A"
502
502
R398
183
94
51
29
600 600
872
675300
190
Ă60
10
Ă60
Tubo 80x40x4
100
193.5
100 12
0
Ă82.5
Ă61
e=12
193.5
Ă88.9
75
360
200
170
15
R50
R406.5
263120
R30
55
Ă29
MATERIAL
ESCALA
POS. NºPZAS.
PESO Kg.
DENOMINACIÓN
MATERIAL
ESCALA
POS. NºPZAS.
PESO Kg.
POS. NºPZAS.NºPZAS.
DIN 931DIN 931
CASQUILLO GUIA GATOMANGUITO SUJECIÓN 6x16
2
DIN 1481DIN 1481
s/plano NM-2445/01/17J
CASQUILLO GUIA GATO
s
/plano NM-2445/01/17J
CASQUILLO GUIA GATO
A
B
C
F
LIN
EA D
E PL
EGA
DO
LIN
EA D
E PL
EGA
DO
DESARROLLO
S275JR1/2
214A
S275JR1/2
214DLPN 50x50x5x719
18
The basic data for the design and thickness calculation are the following ones:
- Filtrating degree - Allowable pressure loss - Filtering surface - Type of cleaning - Flow rate - Pressure - Temperature - Fluid - Materials - Corrosion over thickness - Connections - Space limitations, etc.
At the same time manufacturing is being carried out, a Quality Dossier is being prepared and it will include the following documents:
- Procedures followed - Quality certificates of materials - Welders’ certificate of compliance - Non-destructive trial reports - EC Marking and Compliance Declaration - ASME Data Report - As-Built drawings - Other documents required by the
Customer or the technical or legal regulations.
Design
Quality CertificatesManufacturingManufacturing of filtering equipment and filtration systems is carried out in our facilities in Tabaza, Asturias.
Based on the drawings approved by the customer, our technical department begins the manufacturing process. The customer is invited to be present at any time in any stage of the manufacturing process to check its condition, as well as to attend the final tests required in the specifications or in the design code to be implemented for each case
With reference to the final tests - either the pressure or the operation tests - a certified public body will be responsible for their verification if required by the Customer, Design Code or the EC compliance evaluation procedure.
After manufacturing has been finished, equipment surface is submitted to the relevant treatment and it is prepared for transportation.
In NORTEMECÁNICA we have all the necessary means and resources for the design and manufacturing of filtering equipment and filtration systems.
Based on each customer’s needs and specifications, we make the design of filtering equipment based on the codes to be implemented for each case, i.e. the ASME American code (with optional U stamp), the AD-Merkblatt German code or the EN-13445 European Standard, fulfilling the provisions specified in the Pressure Equipment Directive PED 2014/68/EU.
NºPZAS.
DENOMINACIÓN
CHAPA SOPORTENºPZAS.
DENOMINACIÓN
CHAPA SOPORTE
E J
C
F
Our Quality Management System has been certified by Lloyd’s Register Quality Assurance according to the Quality Assurance Standard ISO 9001:2008.
NORTEMECÁNICA has been certified as manufacturer according to the AD-2000-Merkblatt HP 0 and the EN ISO 3834-2 by TÜV SÜD Industrie Service GmbH.
The company is authorized by ASME (American Society of Mechanical Engineers) as manufacturer of pressure equipment. We have been granted the U seal.
ECA Bureau Veritas has certified that our Quality System fulfils the requirements specified in Module H of the Pressure Equipment Directive PED 2014/68/EU.
Some references - Combined Cycle Power Plant “TARRAGONA I”, Tarragona, Spain (2002) - Combined Cycle Power Plant “ARCOS I” and “ARCOS II”. Cádiz, Spain (2004) - Combined Cycle Power Plant “ACECA”, Toledo, Spain (2005) - Delayer Coker Complex. “Refinería Aconcagua”, Concón, Chile (2006) - Combined Cycle Power Plant “HADJRET IN NOUSS”, Tipaza, Algeria (2008) - Combined Cycle Power Plant “MOERRDIJK”, Brabante, Holland (2010) - Thermo-Solar Power Plant “VALLESOL 1” and “VALLESOL 2”, Cádiz, Spain (2011) - Thermo-Solar Power Plant “LA AFRICANA”, Córdoba, Spain (2012) - Thermo-Solar Power Plant “GENESIS SOLAR ENERGY”, Riverside County, California, USA (2012) - Combined Cycle Power Plant “GREAT ISLAND”, Leinster, Ireland (2013) - Thermo-Solar Power Plant “BOKPOORT CSP”, NORTHERN Cape, South African Republic (2014) - Thermo-Solar “ASHALIM CPS”, Be’er Sheva, Israel (2016)