SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view...

76
SEPTIC TANK SYSTEMS Product Guide Septic Tanks Pump Tanks Single Chamber Tanks Fire Protection/ Water Storage Systems Privy Tanks Oil Interceptors Tank Accessories

Transcript of SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view...

Page 1: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

SEPTIC TANK SYSTEMS Product Guide

Septic Tanks

Pump Tanks

Single Chamber Tanks

Fire Protection/ Water Storage Systems

Privy Tanks

Oil Interceptors

Tank Accessories

Page 2: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

Brooklin Concrete is a precast concrete manufacturer of various designs

and sizes in pump tanks, single chamber tanks, septic tanks, and specialty

systems. We maintain strict quality control during production and offer a

comprehensive line of products. Our complete fleet of crane equipped trucks

can deliver and place your new tank. More importantly, our commitment to

customers extends beyond the sale. Quality, versatility and service, along

with competitive pricing constitute our main strengths.

Our in house design staff can prepare shop drawings for engineer review,

including custom designs if required. No project is too big or small for our

team to offer support.

Thank you for your interest in Brooklin Concrete, we hope you will find this

catalogue a valuable guide in your septic system needs. Included for your

use in this guide are product descriptions, design pages for each item, and

accessory descriptions.

For additional information please call us toll free at 1-800-655-3430

You can also visit our website at www.brooklin.com

Page 3: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

INDEX

Septic Tanks3,600L .................................................1

3,600L Low High ..............................2

4,500L .................................................3

4,500L Low High ..............................4

6,135L .................................................5

7,000L .................................................6

7,500L Low Height ..........................7

9000L ..................................................8

13,650L ..............................................9

13,650L (Ottawa) .......................... 10

18,000L ........................................... 11

22,750L ........................................... 12

30,000 .............................................. 13

36,300L.............................................14

45,500L ........................................... 15

68,200L ........................................... 16

86,000L ........................................... 17

Pump Tanks346L .................................................. 18

680L & 1,365L ............................... 19

2,700L .............................................. 20

3,600L Low Height ....................... 21

3.600L ............................................. 22

4,500L Low Height ....................... 23

4,500L ............................................. 24

6,135L .............................................. 25

7000L ............................................... 26

7,500L Low Height ....................... 27

Single Chamber Tanks9,000L Low Height ....................... 28

9,000L .............................................. 29

11,365L ........................................... 30

13,650L ........................................... 31

18,000L ........................................... 32

22,750L ........................................... 33

30,000L ........................................... 34

36,300L ........................................... 35

45,500L ........................................... 36

72,700L ........................................... 37

90,900L ........................................... 38

Fire Protection/Water Storage Systems22,750L Single .............................. 39

22,750L Nested ............................. 40

30,000L Single .............................. 41

30,000L Nested ............................. 42

45,000L Single .............................. 43

45,000L Nested ............................. 44

90,000L Single .............................. 45

90,000L Nested ............................. 46

Privy TanksPrivy 1000 Low Wood ................. 47

Privy 2500 Wood .......................... 48

Privy 3000 Wood .......................... 49

Privy 4000 Wood .......................... 50

Privy 5000 Wood .......................... 51

Oil Interceptors

Model 65 ......................................... 52

Model 100 ....................................... 53

Model 155 ....................................... 54

Model 250 ....................................... 55

Tank Accessories

Distribution Boxes ........................ 56

Retrofit Lids .................................... 57

Aluminum Accessories............... 58

Warranty & Return Exchange PoliciesWarranty Policy ............................ 61

Company Product PoliciesSpecial Order Policy .................... 63

Return/Exchange Policy ............ 64

Septic Tank Delivery Policy ....... 65

Guidelines & Testing of Tank InstallationInstallation Guidelines ................ 67

Soil Conditions/Back Filling ...... 68

Joint Seal ........................................ 69

Joint Seal Cont. ............................. 70

Testing.............................................. 71

Caution ............................................ 72

Page 4: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa
Page 5: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

1

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

6,4

90lb

s / 2

,943

kgC

PA C

ERTI

FIED

MEE

TS C

SA-B

66

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

2540

[100

"]1372[54"]

1422[56"]

1470[58"] 76

[3"]775

[30 1/2"]

1702[67"]

76 [3"]

2540

[100

"]

851[33 1/2"]

76 [3"]

1372

[54"

]

76[3"]

1778[70"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

TUF-

TITE

EFF

LUEN

TFI

LTER

EF-

6

4" IN

LET

CAS

T-A-

SEAL

402

BAFF

LEBA

FFLE

255

(TYP

.)

OPE

NIN

G 1

2" x

4"

(TYP

.)

127[5"] (TYP.)

152

[6"](

TYP.

)

76 [3"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

DA

TE:

JAN

/ 20

18

2438

[96"

]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

1270

[50"

]

WO

RK

ING

CA

PAC

ITY:

3,7

23 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 4

,259

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

3600

LIT

RES

SEPT

IC T

ANK

800

IMPE

RIA

L G

ALL

ON

DR

AW

N B

Y:S.

RIM

LAN

DM

AN

UFA

CTU

RED

:

BR

OO

KLIN

, ON

1

-800

-655

-343

0

1344

LIQ

UID

DEP

TH

Page 6: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

2

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

6,9

40lb

s / 3

,147

kgC

PA C

ERTI

FIED

MEE

TS C

SA-B

66

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL25

43[1

00"]

1679[66"]

1117[44"]

1167[46"]

76 [3"]

635[25"]

1422[56"]

76 [3"]

2543

[100

"]

76 [3"]

711[28"]

76 [3"]

1679

[66"

]76[3"]

1498[59"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

TUF-

TITE

EFF

LUEN

TFI

LTER

EF-

6

4" IN

LET

CAS

T-A-

SEAL

402

BAFF

LEBA

FFLE

102[4"](TYP.)

152

[6"](

TYP.

)35

7(T

YP.)

OPE

NIN

G 1

2" x

4" (

TYP.

)

2467

[97"

]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

1603

[63"

]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

PaD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

3,6

68 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 4

,450

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

3600

LIT

RES

SEPT

IC T

ANK

800

IMPE

RIA

L G

ALL

ON

LOW

HEI

GH

T

1041

LIQ

UID

DEP

TH

Page 7: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

3

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

8,2

00lb

sC

PA C

ERTI

FIED

MEE

TS C

SA-B

B6-0

0

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

76[3

"] (T

YP.)

838[33"]

76[3

"](TY

P.)

76[3"]

1676[66"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

. 2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

2540

[100

"]

1676[66"]

1472[58"]

1420[56"]

1676[66"]

76[3"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

. 2 R

EQU

IRED

1752[69"]

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

BAFF

LEBA

FFLE

152

(TYP

.)

OPE

NIN

G 1

2" x

4"

(TYP

.)

127[5"] (TYP.)

508

[20"

](TYP

.)

76[3"](TYP.)

2450

[96

1/2"

]15

86[6

2 1/

2"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/ A23

.3. G

30.1

8 Fy

=400

MPa

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

4,6

87 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 5

,287

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

4500

LIT

RES

SEPT

IC T

ANK

1000

IMPE

RIA

L G

ALL

ON

1344

LIQ

UID

DEP

TH

Page 8: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

4

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

11,

620

lbs

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

76[3

"] (T

YP.)

648[25 1/2"]

76 [3"]

76[3"]

1371[54"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

4" IN

LET

CAS

T-A-

SEAL

402

BAFF

LEBA

FFLE

153

(TYP

.)

OPE

NIN

G 1

2" x

4"

(TYP

.)

127[5"] (TYP.)

508

[20"

](TYP

.)

2972

[117

"]

2184[86"]

1067[42"]

1016[40"]

1295[51"]

76[3"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

2082

[82"

]28

70[1

13"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

5,2

14 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 6

,305

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

4500

LIT

RES

SEPT

IC T

ANK

1000

IMPE

RIA

L G

ALL

ON

LOW

HEI

GH

T

940

LIQ

UID

DEP

TH

Page 9: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

5

SEC

TIO

N B

SCAL

E:1/

30SE

CTI

ON

ASC

ALE:

1/30

TOP

VIEW

SCAL

E:1/

30

UN

IT W

EIG

HT:

13,

400

lbs

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

10M

LIF

TIN

G A

NC

HO

R4

REQ

UIR

ED (T

YP.)

3001

[118

1/8

"]2290

[90 1/8"]

1346[53"]

1601[63"]

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

4" IN

LET

CAS

T-A-

SEAL

402

BAFF

LE1269[50"]

724[28 1/2"]

25 [1"]

74[2

7/8

"]

1613[63 1/2"]

10M

LIF

TIN

G A

NC

HO

R4

REQ

UIR

ED (T

YP.)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

140[5 1/2"]

BAFF

LE

DIA

M. 1

27 /

[5"]

(TYP

.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

PaD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

6,1

69 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 7

,192

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

6135

LIT

RES

SEPT

IC T

ANK

1350

IMPE

RIA

L G

ALL

ON

1193

LIQ

UID

DEP

TH

Page 10: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

6

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

TUF-

TITE

EFF

LUEN

TFI

LTER

EF-

6

4" IN

LET

CAS

T-A-

SEAL

402

BAFF

LE

2553[101"]

3213

[126

"]

1321[52"]

1581[62 1/4"]

1270[50"]

UN

IT W

EIG

HT:

14,

460

lbs

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

76[3"](TYP.)

1581[62 1/4"]

775[30 1/2"]

76[3"](TYP.)

76[3

"](TY

P.)

DIA

M. 1

27 [5

"]3

REQ

UIR

ED (T

YP)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

BAFF

LE

550

[21

5/8"

](TYP

.)

76[3

"](TY

P.)

108[4 1/4"]

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

2911

[114

5/8

"]

2214

[87

1/8"

]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

WO

RK

ING

CA

PAC

ITY:

7,5

64 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 8

,892

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

7000

LIT

RES

SEPT

IC T

ANK

1550

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

1194

LIQ

UID

DEP

TH

Page 11: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

7

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FO

R U

NLO

ADIN

GFR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN

OVE

RH

EAD

C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

1232[48 1/2"]

1473[58"]

1181[46 1/2"]

WEI

GH

T:17

,250

lbs

/ 7,8

25kg

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

76[3"](TYP.)

1473[58"]

76[3"](TYP.)

76[3

"](TY

P.)

76[3

"](TY

P.)

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

4039

[159

"]

2286[90"]

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

BAFF

LEBA

FFLE

670

[26

3/8"

]

711[28"]

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

OPE

NIN

GD

IAM

4" (

TYP.

)3

REQ

UIR

ED

SEPT

IC T

ANK

LOW

HEI

GH

T

127[5"]

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

WO

RK

ING

CA

PAC

ITY:

8,2

19 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 9

,624

LIT

RES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

7500

LIT

RES

1650

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

4301092

LIQ

UID

DEP

TH

Page 12: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

8

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FO

R U

NLO

ADIN

GFR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN

OVE

RH

EAD

C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

1423[56"]

1677[66"]

1372[54"] W

EIG

HT:

17,8

95lb

s / 8

,120

kgC

PA C

ERTI

FIED

MEE

TS C

SA-B

B6-0

0

76[3"](TYP.)

1677[66"]

76[3"](TYP.)

76[3

"](TY

P.)

76[3

"](TY

P.)

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

4039

[159

"]

2286[90"]

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

BAFF

LEBA

FFLE

670

[26

3/8"

]

686[27"]

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

6

OPE

NIN

GD

IAM

4" (

TYP.

)3

REQ

UIR

ED

127[5"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

4" IN

LET

CAS

T-A-

SEAL

402

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

WO

RK

ING

CA

PAC

ITY:

9,7

55 L

ITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 1

1,16

9 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

9000

LIT

RES

SEPT

IC T

ANK

2000

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

1295

LIQ

UID

DEP

TH

Page 13: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

9

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PEAT

TH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FTIS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 2

9,30

0lbs

/ 13

,290

kgC

PA C

ERTI

FIED

WO

RK

ING

CA

PAC

ITY:

13,

797

LITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 1

6,92

0 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

1365

0 L

ITR

ES

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

62

REQ

UIR

ED

4" IN

LET

CAS

T-A-

SEAL

402

4" O

UTL

ETC

AST-

A-SE

AL 4

02

SEC

TIO

N A

SCAL

E:1/

50

1753[69"]

1423[56"]

1346 [53"]

108[4 1/4"]

127[5"]

SEC

TIO

N B

SCAL

E:1/

50

OPE

NIN

G23

4"X1

2"(T

YP.)

3 R

EQU

IRED

1753[69"]

2591

[102

"]50

55[1

99"]

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

62

REQ

UIR

ED

BAFF

LE

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

305

[12"

]

70[2 3/4"]

OPE

NIN

GD

IAM

. 4"(

TYP.

)3

REQ

UIR

ED

108[4 1/4"]

87[3

3/8

"]

127

[5"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

280[11"]

127[5"]

1238

LIQ

UID

DEP

TH

3,00

0 IM

PER

IAL

GA

LLO

N

SEPT

IC

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

TAN

K

Page 14: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

10

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 2

6,14

2lbs

/ 11

,857

kgB

OTT

OM

: 13,

071l

bsTO

P: 1

3,07

1lbs

CPA

CER

TIFI

ED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

SEC

TIO

N A

SCAL

E:1/

50

1727[68"]

864[34"]

1383 [54 1/2"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

OPE

NIN

GD

IAM

. 4" (

TYP.

)3

REQ

UIR

ED

2591

[102

"]50

55[1

99"]

108[4 1/4"]12

7[5

"]

274

[10

3/4"

]

127[5"]

127

[5"] 86

[3 3

/8"]

BAFF

LE

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

5-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

864[34"]

1435[56 1/2"]

4" IN

LET

CAS

T-A-

SEAL

402

4" O

UTL

ETC

AST-

A-SE

AL 4

02

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

62

REQ

UIR

ED

TUF-

TITE

EFFL

UEN

TFI

LTER

EF-

62

REQ

UIR

ED12

75LI

QU

ID D

EPTH

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

WO

RK

ING

CA

PAC

ITY:

14,

211

LITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 1

6,76

5 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

1365

0 L

ITR

ESSE

PTIC

3,00

0 IM

PER

IAL

GA

LLO

ND

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

TAN

K

Page 15: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

11

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 3

1,14

0lbs

/ 14

,125

kgB

OTT

OM

: 15,

780l

bsTO

P: 1

5,36

0lbs

CPA

CER

TIFI

ED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

4" IN

LET

CAS

T-A-

SEAL

402

4" O

UTL

ETC

AST-

A-SE

AL 4

02

SEC

TIO

N A

SCAL

E:1/

50

2096[82 1/2"]

1810[71 1/4"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

OPE

NIN

GD

IAM

. 4" (

TYP.

)3

REQ

UIR

ED

2096[82 1/2"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]12

7[5

"]

274

[10

3/4"

]

127[5"]

127

[5"] 86

[3 3

/8"]

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

PL-5

25 E

FFLU

ENT

FILT

ER

PL-5

25 E

FFLU

ENT

FILT

ER

BAFF

LE

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

4"PV

C C

AP T

AP C

ON

TO W

ALL

w/4

" PVC

TEE

GLU

E TO

CAP

1758[69 1/4"]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

18,

470

LITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 2

1,00

7 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

1800

0 LI

TRES

SEPT

IC40

00 IM

PER

IAL

GA

LLO

NTA

NK

1344

LIQ

UID

DEP

TH

Page 16: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

12

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAFE

AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 3

4,87

0lbs

/ 15

,820

kgC

PA C

ERTI

FIED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

4" IN

LET

CAS

T-A-

SEAL

402

4" O

UTL

ETC

AST-

A-SE

AL 4

02

SEC

TIO

N A

SCAL

E:1/

50

2527[99 1/2"]

2235[88"]

2184[86"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

OPE

NIN

GD

IAM

. 4" (

TYP.

)3

REQ

UIR

ED

2527[99 1/2"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]12

7[5

"]

274

[10

3/4"

]

127[5"]

127

[5"] 86

[3 3

/8"]

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

PL-5

25 E

FFLU

ENT

FILT

ER

PL-5

25 E

FFLU

ENT

FILT

ER

BAFF

LE

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

4"PV

C C

AP T

AP C

ON

TO W

ALL

w/4

" PVC

TEE

GLU

E TO

CAP

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

23,

248

LITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 2

5,85

3 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

2275

0 LI

TRES

SEPT

IC50

00 IM

PER

IAL

GA

LLO

NTA

NK

2076

LIQ

UID

DEP

TH

Page 17: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

13

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PEAT

TH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N

MU

ST

BE

REA

DY,

SA

FEAN

D

ACC

ESSI

BLE

FOR

U

NLO

ADIN

GFR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

WEI

GH

T: 4

0,90

5lbs

/ 18

,555

kgC

PA C

ERTI

FIED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

PL-5

25 E

FFLU

ENT

FILT

ER

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

PL-5

25 E

FFLU

ENT

FILT

ER

4" IN

LET

CAS

T-A-

SEAL

402

4" O

UTL

ETC

AST-

A-SE

AL 4

02

4"PV

C C

AP T

AP C

ON

TO W

ALL

w/4

" PVC

TEE

GLU

E TO

CAP

SEC

TIO

N A

SCAL

E:1/

50

3251[128"]

2877[113 1/4"]

2826[111 1/4"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

OPE

NIN

GD

IAM

. 4" (

TYP.

)3

REQ

UIR

ED

3251[128"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]12

7[5

"]

274

[10

3/4"

]

127[5"]

127

[5"] 86

[3 3

/8"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

WO

RK

ING

CA

PAC

ITY:

30,

404

LITR

ES T

O IN

VER

T O

F O

UTL

ET

TOTA

L C

APA

CIT

Y: 3

3,91

8 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

3000

0 LI

TRES

SEPT

IC66

00 IM

PER

IAL

GA

LLO

NTA

NK

2768

LIQ

UID

DEP

TH

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

Page 18: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

14

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PEAT

TH

E JO

INTS

2.M

OBI

LE C

RAN

E R

EQU

IRED

ON

SIT

E TO

UN

LOAD

TH

E TA

NK

3.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

4.SC

HEM

ATIC

ON

LY (F

UR

THER

DET

AILS

UPO

N R

EQU

EST)

5.M

AXIM

UM

BU

RIA

L D

EPTH

=30"

GEN

ERA

L N

OTE

S:

CSA

APP

RO

VED

WEI

GH

T: 3

9,00

0lbs

/ 17

,690

kg (T

OP)

3

9,00

0lbs

/ 17

,690

kg (B

OTT

OM

)

8,00

0 IM

PER

IAL

GAL

LON

/ 36

,300

LIT

RES

SEP

TIC

TAN

K.

CO

NC

RET

E: 4

5MPa

/650

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: M

EETS

G30

.14-

M19

83

SEC

TIO

N A

SCAL

E:1/

60

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N B

SCAL

E:1/

60

7315

[288

"]

2540[100"]

2159[85"]

2083[82"]

3048

[120

"]

152[6"]

1118[44"]

152

[6"]

152

[6"]

152

[6"]

2269

[89

3/8"

]15

2[6

"]

152[6"]

3048[120"]

152[6"]

127

[5"]

7315

[288

"]15

2[6

"]

152[6"]

152[6"]

2540[100"]

24" x

12"

TU

F-TI

TER

ISER

WIT

H C

OVE

R.

2 R

EQU

IRED

CAS

T-A-

SEAL

964

- 4.2

1"O

D-6

.9"O

DBAFF

LE

PL-5

25EF

FLU

ENT

FILT

ER.

4" P

VCPO

LYSE

AL

24" x

12" T

UF-

TITE

RIS

ER W

ITH

CO

VER

.2

REQ

UIR

ED

4" P

VC C

AP T

AP C

ON

TO W

ALL

w/4

" PVC

TEE

GLU

E TO

CAP

6"x1

2"O

PEN

ING

S.2

REQ

.

2"X4

5"O

PEN

ING

2743

[108

"]

2236[88"]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1

-800

-655

-343

0

3630

0 LI

TRES

SEPT

IC80

00 IM

PER

IAL

GA

LLO

NTA

NK

Page 19: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

15

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N A

SCAL

E:1/

60

SEC

TIO

N B

SCAL

E:1/

60

7315

[288

"]3048[120"]

3048

[120

"]

1524[60"]

1473[58"]

2997[118"]

2997[118"]

7315

[288

"]

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.BU

RIA

L D

EPTH

= 30

"

GEN

ERA

L N

OTE

S:

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

MEE

TS G

30.1

4-M

1983

CSA

APP

RO

VED

WEI

GH

T: 5

0,70

0lbs

/ 23

,000

kg (T

OP)

5

0,70

0lbs

/ 23

,000

kg (B

OTT

OM

)

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2R

EQU

IRED

(TYP

.)

2"X4

5"O

PEN

ING

6"X1

2"O

PEN

ING

. 2R

EQU

IRED

203 [8"]

76 [3"]

203

[8"]

203

[8"]

2132

[83

7/8"

]20

3 [8

"]45

74[1

80 1

/8"]

203

[8"]

2616[103"]

2565[101"]

OU

TLET

4" P

VCPO

LYSE

AL

INLE

T 4"

PVC

POLY

SEAL

170[6 3/4"]

2642[104"]

10,0

00 IM

PER

IAL

GAL

LON

/ 45

,500

LIT

RES

SEP

TIC

TAN

KD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1

-800

-655

-343

0

4550

0 LI

TRES

SEPT

IC10

,000

IMPE

RIA

L G

ALL

ON

TAN

K

PL-5

25 E

FFLU

ENT

FILT

ER

4"PV

C C

AP T

AP C

ON

TO W

ALL

w/4

" PVC

TEE

GLU

E TO

CAP

PL-5

25 E

FFLU

ENT

FILT

ER

Page 20: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

16

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT

: ST

EEL

TO C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

CPA

CER

TIFI

EDW

EIG

HT:

63,

150l

bs/2

8,64

5kg

(TO

P)

81,

625l

bs/3

7,02

5kg

(BO

TTO

M)

9145

[360

"]20

3[8

"] (T

YP)

2745

[108

1/8

"]20

3[8

"]

203

[8"]

3660[144 1/8"]

3050[120 1/8"]

203

[8"](

TYP.

)

203[8"](TYP.)

77 [3"]

9145

[360

"]

1800[70 7/8"]

1250[49 1/4"]

3660

[144

1/8

"]

2670[105 1/8"]

4" P

VC IN

LET

4" P

VCO

UTL

ET

2600[102 3/8"]

15,0

00 IM

PER

IAL

GAL

LON

/ 68

,200

LIT

RES

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30

SEC

TIO

N B

SCAL

E:1/

30

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.R

EIN

FOR

CEM

ENT

TO C

ON

FOR

M T

OC

SA-G

30.1

2-40

0Pa

3.BU

RIA

L D

EPTH

: 30"

4.R

EIN

FOR

CEM

ENT

TAN

K: 2

0M @

150

O/C

BO

TH W

AYS

LID

: 20M

@ 1

50 O

/C B

OTH

WAY

S

5.4"

PV

C

SUPP

OR

T PI

PE

FOR

EFFL

UEN

T FI

LTER

NO

T PR

OVI

DED

GEN

ERA

L N

OTE

S:

203[8"](TYP.)

12" X

4" O

PEN

ING

(TYP

.)

12" x

4" O

PEN

ING

(TYP

.)

PL-5

25 E

FFLU

ENT

FILT

ER2

REQ

UIR

ED

6" X

20"

OPE

NIN

G2

REQ

UIR

ED (T

YP.)

203

[8"]

833

[32

3/4"

]

NO

TE 5

DA

TE:

JAN

/ 20

18

DR

AW

N B

Y:S.

RIM

LAN

D

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1-80

0-65

5-34

30

6820

0 LI

TRES

SEPT

IC15

000

IMPE

RIA

L G

ALL

ON

TAN

K

1047[41 1/4"]

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

2 R

EQU

IRED

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

2 R

EQU

IRED

EZse

t 12"

X 3

0" R

ISER

WIT

H C

OVE

R1

REQ

UIR

ED

EZse

t 12"

X 3

0" R

ISER

WIT

H C

OVE

R1

REQ

UIR

ED

Page 21: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

17

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT

: ST

EEL

TO C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

CPA

CER

TIFI

EDW

EIG

HT:

81,

065l

bs/3

6,77

0kg

(TO

P)

8

1,62

5lbs

/37,

025k

g (B

OTT

OM

)

9145

[360

"]20

3[8

"] (T

YP)

2745

[108

1/8

"]20

3[8

"]

203

[8"]

3660[144 1/8"]

3607[142"]

77 [3"]

9145

[360

"]

203[8"](TYP.)

3660

[144

1/8

"]

12"x

4" O

PEN

ING

(TYP

.)

203[8"](TYP.)20

3[8

"](TY

P.)

152

[6"](

TYP.

)

3230[127 1/8"]

CAS

T-A-

SEAL

964

- 4.2

1"O

D-6

.9"O

D

4" P

VCO

UTL

ET

3150[124"]

18,9

00 IM

PER

IAL

GAL

LON

/ 86

,000

LIT

RES

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

2 R

EQU

IRED

EZse

t 12"

X 3

0" R

ISER

WIT

H C

OVE

R1

REQ

UIR

ED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30

SEC

TIO

N B

SCAL

E:1/

30

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.R

EIN

FOR

CEM

ENT

TO C

ON

FOR

M T

OC

SA-G

30.1

2-40

0Pa

3.BU

RIA

L D

EPTH

: 30"

4.R

EIN

FOR

CEM

ENT

TAN

K: 2

0M @

150

O/C

BO

TH W

AYS

LID

: 20M

@ 1

50 O

/C B

OTH

WAY

S

5.4"

PV

C

SUPP

OR

T PI

PE

FOR

EFFL

UEN

T FI

LTER

NO

T PR

OVI

DED

GEN

ERA

L N

OTE

S:

1804[71"]

1804[71"]

838

[33"

]PL

-525

EFF

LUEN

TFI

LTER

. 2 R

EQ.

6"x

20"

OPE

NIN

G(T

YP.)

NO

TE 5

DA

TE:

JAN

/ 20

18

DR

AW

N B

Y:S.

RIM

LAN

D

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1-80

0-65

5-34

30

8600

0 LI

TRES

SEPT

IC18

900

IMPE

RIA

L G

ALL

ON

TAN

K

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

2 R

EQU

IRED

EZse

t 12"

X 3

0" R

ISER

WIT

H C

OVE

R1

REQ

UIR

ED

Page 22: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

18

TOP

VIEW

SCAL

E:1/

16

SEC

TIO

N A

SCAL

E:1/

16

889[35"]

597[23 1/2"]

584[23"]

737[29"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

1 R

EQU

IRED 4"

OU

TLET

PVC

POLY

SEAL1067

[42"]

914[36"]

WEI

GH

T:1,

460l

bs /

662k

gC

PA C

ERTI

FIED

MEE

TS C

SA-B

B6-0

0

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

3" D

IAL

CO

RD

SEA

L

3" D

IAL

CO

RD

SEA

L

76[3"]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

364

LITR

ESPU

MP

TAN

K80

IMPE

RIA

L G

ALL

ON

4" IN

LET

PVC

POLY

SEAL

51[2"]

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

80 IM

PER

IAL

GAL

LON

/ 36

4 LI

TRES

PU

MP

TAN

K

Page 23: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

19

680

& 13

65 L

ITR

ES T

OP

VIEW

SCAL

E: 1

/20

1365

LIT

RES

SEC

TIO

N A

SCAL

E: 1

/20

680

LIT

RES

SEC

TIO

N A

SCAL

E: 1

/20

CPA

CER

TIFI

EDW

EIG

HT:

680

LITR

ES- 2

,520

lbs

/ 1,1

43kg

1365

LIT

RES

- 3,5

60 lb

s / 1

,614

kg

1346

[53"

]76

[3"]

(TYP

.)

1270[50"]

76[3"] (TYP.)

1359[53 1/2"]

1143[45"]

2" O

UTL

ETC

AST-

A-SE

AL 4

024"

INLE

TC

AST-

A-SE

AL 4

02

76[3"] (TYP.)

76[3"] (TYP.)

3" D

IAL

CO

RD

SEA

L

1092[43"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3" D

IAL

CO

RD

SEA

L

838[33"]

621[24 1/2"]

594[23 1/2"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3" D

IAL

CO

RD

SEA

L

1346

[53"

]

1346

[53"

]

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

76 [3"]

88 [3

1/2

"]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

680

& 13

65 L

ITR

ESPU

MP

150

& 3

00 IM

PER

IAL

GA

LLO

NTA

NK

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

150

& 30

0 IM

PER

IAL

GAL

LON

/ 68

0 &

1365

LIT

RES

Page 24: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

20

UN

IT W

EIG

HT:

5,7

20lb

sC

PA C

ERTI

FIED

MEE

TS C

SA-B

B6-0

0

TOP

VIEW

SCAL

E:1/

30

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

(TYP

.)

SEC

TIO

N A

SCAL

E:1/

30

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

SEC

TIO

N B

SCAL

E:1/

30

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PEAT

TH

E JO

INTS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D

ACC

ESSI

BLE

FO

R

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FTIS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL

AWAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S: 3" D

IAM

ETER

CO

RD

SEA

L

2438

[96"

]1219[48"]

1625[64"]

1346[53"]

737[29"]

76 [3"]

76 [3"]

76 [3"]

2438

[96"

]

1295[51"]

4" IN

LET

CAS

T-A-

SEAL

402

76[3"]

1625[64"]

813[32"]

76 [3"]

1219

[48"

]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

4" IN

LET

CAS

T-A-

SEAL

402

1346[53"]

2" O

UTL

ETC

AST-

A-SE

AL 4

02

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

2386

[94"

]11

42[4

5"]

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

2700

LIT

RES

PUM

P TA

NK

600

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

600

IMPE

RIA

L G

ALLO

N /

2,70

0 LI

TRES

Page 25: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

21

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

6,9

40lb

s / 3

,147

kgC

PA C

ERTI

FIED

MEE

TS C

SA-B

66

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL25

43[1

00"]

1679[66"]

1117[44"]

1167[46"]

76 [3"]

635[25"]

1422[56"]

76 [3"]

2543

[100

"]

76 [3"]

711[28"]

76 [3"]

1679

[66"

]76[3"]

1498[59"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

800

IMPE

RIA

L G

ALLO

N /

3,60

0 LI

TRES

2467

[97"

]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

1603

[63"

]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

PaD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

3600

LIT

RES

PUM

P TA

NK

800

IMPE

RIA

L G

ALL

ON

LOW

HEI

GH

T

3" D

IAM

ETER

CO

RD

SEA

L3"

DIA

MET

ERC

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

Page 26: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

22

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

6,4

90lb

s / 2

,943

kgC

PA C

ERTI

FIED

MEE

TS C

SA-B

66

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

2540

[100

"]1372[54"]

1422[56"]

1470[58"] 76

[3"]775

[30 1/2"]

1702[67"]

76 [3"]

2540

[100

"]

851[33 1/2"]

76 [3"]

1372

[54"

]

76[3"]

1778[70"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

800

IMPE

RIA

L G

ALLO

N /

3,60

0 LI

TRES

76 [3"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

DA

TE:

JAN

/ 20

18

2438

[96"

]12

70[5

0"]

3600

LIT

RES

PUM

P TA

NK

800

IMPE

RIA

L G

ALL

ON

DR

AW

N B

Y:S.

RIM

LAN

DM

AN

UFA

CTU

RED

:

BR

OO

KLIN

, ON

1

-800

-655

-343

0

3" D

IAM

ETER

CO

RD

SEA

L3"

DIA

MET

ERC

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

Page 27: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

23

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

11,

620

lbs

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

76[3

"] (T

YP.)

648[25 1/2"]

76 [3"]

76[3"]

1371[54"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

1000

IMPE

RIA

L G

ALLO

N /

4,50

0 LI

TRES

2972

[117

"]

2184[86"]

1067[42"]

1016[40"]

1295[51"]

76[3"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

2082

[82"

]28

70[1

13"]

24" x

6" T

UF-

TITE

RIS

ERW

ITH

CO

VER

. 2 R

EQU

IRED

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

4500

LIT

RES

PUM

P TA

NK

1000

IMPE

RIA

L G

ALL

ON

LOW

HEI

GH

T

3" D

IAM

ETER

CO

RD

SEA

L3"

DIA

MET

ERC

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

Page 28: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

24

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

8,2

00lb

sC

PA C

ERTI

FIED

MEE

TS C

SA-B

B6-0

0

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

76[3

"] (T

YP.)

838[33"]

76[3

"](TY

P.)

76[3"]

1676[66"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

. 2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

1000

IMPE

RIA

L G

ALLO

N /

4,50

0 LI

TRES

2540

[100

"]

1676[66"]

1472[58"]

1420[56"]

1676[66"]

76[3"]

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

. 2 R

EQU

IRED

1752[69"]

76[3"](TYP.)

2450

[96

1/2"

]15

86[6

2 1/

2"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/ A23

.3. G

30.1

8 Fy

=400

MPa

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

4500

LIT

RES

PUM

P TA

NK

1000

IMPE

RIA

L G

ALL

ON

3" D

IAM

ETER

CO

RD

SEA

L3"

DIA

MET

ERC

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

Page 29: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

25

SEC

TIO

N B

SCAL

E:1/

30SE

CTI

ON

ASC

ALE:

1/30

TOP

VIEW

SCAL

E:1/

30

UN

IT W

EIG

HT:

13,

400

lbs

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

10M

LIF

TIN

G A

NC

HO

R4

REQ

UIR

ED (T

YP.)

3001

[118

1/8

"]

2290[90 1/8"]

1346[53"]

1601[63"]

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

1269[50"]

25 [1"]

74[2

7/8

"]

1613[63 1/2"]

10M

LIF

TIN

G A

NC

HO

R4

REQ

UIR

ED (T

YP.)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

140[5 1/2"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

PaD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

6135

LIT

RES

PUM

P TA

NK

1350

IMPE

RIA

L G

ALL

ON

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

1350

IMPE

RIA

L G

ALLO

N /

6,13

5 LI

TRES

Page 30: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

26

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

2553[101"]

3213

[126

"]1321[52"]

1581[62 1/4"]

1270[50"]

UN

IT W

EIG

HT:

14,

460

lbs

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

76[3"](TYP.)

1581[62 1/4"]

76[3"](TYP.)

76[3

"](TY

P.)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

76[3

"](TY

P.)

108[4 1/4"]

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

2911

[114

5/8

"]

2214

[87

1/8"

]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

7000

LIT

RES

PUM

P TA

NK

1550

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

1550

IMPE

RIA

L G

ALLO

N /

7,00

0 LI

TRES

Page 31: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

27

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FO

R U

NLO

ADIN

GFR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN

OVE

RH

EAD

C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

2" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

1232[48 1/2"]

1473[58"]

1181[46 1/2"]

WEI

GH

T:17

,250

lbs

/ 7,8

25kg

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

76[3"](TYP.)

1473[58"]

76[3"](TYP.)

76[3

"](TY

P.)

76[3

"](TY

P.)

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

4039

[159

"]

2286[90"]

PUM

P TA

NK

LOW

HEI

GH

T

127[5"]

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

7500

LIT

RES

1650

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

*WIL

L BE

CO

NVE

RTI

NG

TO

A 2

" CAS

T-A-

SEAL

OU

TLET

FO

R 2

018*

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

1650

IMPE

RIA

L G

ALLO

N /

7,50

0 LI

TRES

Page 32: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

28

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN

OVE

RH

EAD

C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

1219[48"]

WEI

GH

T:16

,050

lbs

/ 7,2

80kg

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

76[3"](TYP.)

1473[58"]

76[3"](TYP.)

76[3

"](TY

P.)

76[3

"](TY

P.)

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

INLE

T 4"

PVC

POLY

SEAL

INLE

TO

N L

ID

3" D

IAM

ETER

CO

RD

SEA

L

4" IN

LET

CAS

T-A-

SEAL

402

4039

[159

"]

2286[90"]

127[5"]

SIN

GLE

CH

AMBE

RLO

W H

EIG

HT

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

3" D

IAM

ETER

CO

RD

SEA

L

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

3" D

IAM

ETER

CO

RD

SEA

L

1472[58"]

1524[60"]

*9,0

00 L

ITR

ES

TO

RO

OF*

4" IN

LET

CAS

T-A-

SEAL

402

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

9000

LIT

RES

2000

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

2,00

0 IM

PER

IAL

GAL

LON

/ 9,

000

LITR

ES S

ING

LE C

HAM

BER

1168[46"]

4" O

UTL

ET P

VCPO

LYSE

AL

Page 33: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

29

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FO

R U

NLO

ADIN

GFR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN

OVE

RH

EAD

C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

1423[56"]

1677[66"]

WEI

GH

T:17

,895

lbs

/ 8,1

20kg

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

76[3"](TYP.)

1677[66"]

76[3"](TYP.)

76[3

"](TY

P.)

76[3

"](TY

P.)

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

4" IN

LET

CAS

T-A-

SEAL

402

4039

[159

"]

2286[90"]

127[5"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

2 R

EQU

IRED

4" IN

LET

CAS

T-A-

SEAL

402

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

9000

LIT

RES

SIN

GLE

2000

IMPE

RIA

L G

ALL

ON

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

3" D

IAM

ETER

CO

RD

SEA

L

CH

AMBE

R

3" D

IAM

.C

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L

2,00

0 IM

PER

IAL

GAL

LON

/ 9,

000

LITR

ES S

ING

LE C

HAM

BER

1372[54"]4"

OU

TLET

PVC

POLY

SEAL

Page 34: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

30

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 2

7,18

0lbs

/ 12

,330

kg

CPA

CER

TIFI

ED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

4" IN

LET

CAS

T-A-

SEAL

402

SEC

TIO

N A

SCAL

E:1/

50

1499[59"]

1194[47"]

108[4 1/4"]

127[5"]

SEC

TIO

N B

SCAL

E:1/

50

1524[60"]

2591

[102

"]50

55[1

99"]

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

108[4 1/4"]

87[3

3/8

"]

127

[5"]

4" IN

LET

CAS

T-A-

SEAL

402

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

3" D

IAM

ETER

CO

RD

SEA

L

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

1136

5 LI

TRES

SIN

GLE

2500

IMPE

RIA

L G

ALL

ON

CH

AMBE

R2,

500

IMPE

RIA

L G

ALLO

N /

11,3

65 L

ITR

ES S

ING

LE C

HAM

BER

1143[45"]

4" O

UTL

ET P

VCPO

LYSE

AL

Page 35: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

31

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 2

6,14

2lbs

/ 11

,857

kg

CPA

CER

TIFI

ED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

SEC

TIO

N A

SCAL

E:1/

50

1727[68"]

864[34"]

1383 [54 1/2"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

2591

[102

"]50

55[1

99"]

108[4 1/4"]

127

[5"] 86

[3 3

/8"]

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

5-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

864[34"]

1435[56 1/2"]

4" IN

LET

CAS

T-A-

SEAL

402

4" O

UTL

ETPV

C P

OLY

SEAL

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

1365

0 L

ITR

ES3,

000

IMPE

RIA

L G

ALL

ON

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

SIN

GLE

CH

AMBE

R3,

000

IMPE

RIA

L G

ALLO

N /

13,6

50 L

ITR

ES S

ING

LE C

HAM

BER

3" D

IAM

.C

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L3"

DIA

MET

ERC

OR

D S

EAL

4" IN

LET

CAS

T-A-

SEAL

402

Page 36: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

32

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 3

1,14

0lbs

/ 14

,125

kgB

OTT

OM

: 15,

780l

bsTO

P: 1

5,36

0lbs

CPA

CER

TIFI

ED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

4" IN

LET

CAS

T-A-

SEAL

402

SEC

TIO

N A

SCAL

E:1/

50

2096[82 1/2"]

1810[71 1/4"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

2096[82 1/2"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]

127

[5"] 86

[3 3

/8"]

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

1800

0 LI

TRES

SIN

GLE

4000

IMPE

RIA

L G

ALL

ON

CH

AMBE

R

3" D

IAM

ETER

CO

RD

SEA

L

4" IN

LET

CAS

T-A-

SEAL

402

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

4,00

0 IM

PER

IAL

GAL

LON

/ 18

,000

LIT

RES

SIN

GLE

CH

AMBE

R

1759[69 1/4"]

4" O

UTL

ET P

VCPO

LYSE

AL

Page 37: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

33

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAFE

AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 3

4,87

0lbs

/ 15

,820

kgC

PA C

ERTI

FIED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

4" IN

LET

CAS

T-A-

SEAL

402

SEC

TIO

N A

SCAL

E:1/

50

2527[99 1/2"]

2235[88"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

2527[99 1/2"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]

127

[5"] 86

[3 3

/8"]

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys/5

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

2275

0 LI

TRES

SIN

GLE

5000

IMPE

RIA

L G

ALL

ON

CH

AMBE

R

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

3" D

IAM

ETER

CO

RD

SEA

L

4" IN

LET

CAS

T-A-

SEAL

402

5,00

0 IM

PER

IAL

GAL

LON

/ 22

,750

LIT

RES

SIN

GLE

CH

AMBE

R

2184[86"]

4" O

UTL

ET P

VCPO

LYSE

AL

Page 38: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

34

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PEAT

TH

E JO

INTS

2.D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N

MU

ST

BE

REA

DY,

SA

FEAN

D

ACC

ESSI

BLE

FOR

U

NLO

ADIN

GFR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

WEI

GH

T: 4

0,90

5lbs

/ 18

,555

kgC

PA C

ERTI

FIED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

4" IN

LET

CAS

T-A-

SEAL

402

SEC

TIO

N A

SCAL

E:1/

50

3251[128"]

2877[113 1/4"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

3251[128"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]

127

[5"] 86

[3 3

/8"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

TUFF

TIT

E 24

" CO

VER

WIT

H 6

"X24

" RIS

ER2

REQ

UIR

ED (T

YP.)

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

3000

0 LI

TRES

SIN

GLE

6600

IMPE

RIA

L G

ALL

ON

CH

AMBE

R

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

3" D

IAM

ETER

CO

RD

SEA

L3"

DIA

MET

ERC

OR

D S

EAL

3" D

IAM

ETER

CO

RD

SEA

L

4" IN

LET

CAS

T-A-

SEAL

402

6,60

0 IM

PER

IAL

GAL

LON

/ 30

,000

LIT

RES

SIN

GLE

CH

AMBE

R

2826[111 1/4"]

4" O

UTL

ET P

VCPO

LYSE

AL

Page 39: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

35

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PEAT

TH

E JO

INTS

2.M

OBI

LE C

RAN

E R

EQU

IRED

ON

SIT

E TO

UN

LOAD

TH

E TA

NK

3.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

4.SC

HEM

ATIC

ON

LY (F

UR

THER

DET

AILS

UPO

N R

EQU

EST)

5.M

AXIM

UM

BU

RIA

L D

EPTH

=30"

GEN

ERA

L N

OTE

S:

8,00

0 IM

PER

IAL

GAL

LON

/ 36

,300

LIT

RES

SIN

GLE

CH

AMBE

R T

ANK

CO

NC

RET

E: 4

5MPa

/650

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: M

EETS

G30

.14-

M19

83

SEC

TIO

N A

SCAL

E:1/

60

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N B

SCAL

E:1/

60

7315

[288

"]

2540[100"]

2159[85"]

3048

[120

"]

152[6"]

1118[44"]

152

[6"]

152

[6"]

152

[6"]

152

[6"]

152[6"]

3048[120"]

152[6"]

7315

[288

"]15

2[6

"]

152[6"]

152[6"]

2540[100"]

24" x

12"

TU

F-TI

TER

ISER

WIT

H C

OVE

R.

2 R

EQU

IRED

CAS

T-A-

SEAL

964

- 4.2

1"O

D-6

.9"O

DBAFF

LE

24" x

12" T

UF-

TITE

RIS

ER W

ITH

CO

VER

.2

REQ

UIR

ED22

69[8

9 3/

8"]

127

[5"]

6"x1

2"O

PEN

ING

S.2

REQ

.

2"X4

5"O

PEN

ING

24"X

24"

(600

mm

X600

mm

)KN

OC

KOU

T PA

NEL

.

2083[82"]4"

OU

TLET

PVC

POLY

SEAL

3" D

IAM

ETER

CO

RD

SEA

L

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1

-800

-655

-343

0

3630

0 LI

TRES

SIN

GLE

8000

IMPE

RIA

L G

ALL

ON

CH

AMBE

RC

SA A

PPR

OVE

DW

EIG

HT:

39,

000l

bs /

17,6

90kg

(TO

P)

39,

000l

bs /

17,6

90kg

(BO

TTO

M)

Page 40: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

36

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N A

SCAL

E:1/

60

SEC

TIO

N B

SCAL

E:1/

60

7315

[288

"]3048[120"]

3048

[120

"]

1524[60"]

1473[58"]

2997[118"]

2997[118"]

7315

[288

"]

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.BU

RIA

L D

EPTH

= 30

"

GEN

ERA

L N

OTE

S:

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

MEE

TS G

30.1

4-M

1983

CSA

APP

RO

VED

WEI

GH

T: 5

0,70

0lbs

/ 23

,000

kg (T

OP)

5

0,70

0lbs

/ 23

,000

kg (B

OTT

OM

)

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2R

EQU

IRED

(TYP

.)

2"X4

5"O

PEN

ING

6"X1

2"O

PEN

ING

. 2R

EQU

IRED

203 [8"]

24"X

24"

(600

mm

X600

mm

)KN

OC

KOU

T PA

NEL

.

76 [3"]

203

[8"]

203

[8"]

2132

[83

7/8"

]20

3 [8

"]45

74[1

80 1

/8"]

203

[8"]

2616[103"]

2565[101"]

OU

TLET

4" P

VCPO

LYSE

AL

INLE

T 4"

PVC

POLY

SEAL

170[6 3/4"]

2642[104"]

10,0

00 IM

PER

IAL

GAL

LON

/ 45

,500

LIT

RES

SIN

GLE

CH

AMBE

R T

ANK

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1

-800

-655

-343

0

4550

0 LI

TRES

SIN

GLE

10,0

00 IM

PER

IAL

GA

LLO

NC

HAM

BER

Page 41: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

37

9145

[360

"]20

3[8

"] (T

YP)

2745

[108

1/8

"]20

3[8

"]

203

[8"]

3660[144 1/8"]

3050[120 1/8"]

203

[8"](

TYP.

)

203[8"](TYP.)

77 [3"]

9145

[360

"]

1800[70 7/8"]

1250[49 1/4"]

3660

[144

1/8

"]

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30

SEC

TIO

N B

SCAL

E:1/

30

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.R

EIN

FOR

CEM

ENT

TO C

ON

FOR

M T

OC

SA-G

30.1

2-40

0Pa

3.R

EIN

FOR

CEM

ENT

TAN

K: 2

0M @

150

O/C

BO

TH W

AYS

LID

: 20M

@ 1

50 O

/C B

OTH

WAY

S

GEN

ERA

L N

OTE

S:

203[8"](TYP.)

203

[8"]

12" X

4" O

PEN

ING

(TYP

.)

12" x

4" O

PEN

ING

(TYP

.)

2' X

2' O

PEN

ING

(TYP

.)

610[24"]

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

838

[33"

]

447

[17

5/8"

]

*16,

000

IMPE

RIA

L G

ALL

ON

/72

,700

LIT

RES

TO

RO

OF

2671[105 1/8"]

2601[102 3/8"]

4" P

VC P

OLY

SEAL

CAS

T-A-

SEAL

964

-4.

21" O

D-6

.9"O

D

16,0

00 IM

PER

IAL

GAL

LON

/ 72

,700

LIT

RES

SIN

GLE

CH

AMBE

R T

ANK

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1

-800

-655

-343

0

7270

0 LI

TRES

SIN

GLE

16,0

00 IM

PER

IAL

GA

LLO

NC

HAM

BER

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT

: ST

EEL

TO C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

CPA

CER

TIFI

EDW

EIG

HT:

63,

150l

bs/2

8,64

5kg

(TO

P)

81,

625l

bs/3

7,02

5kg

(BO

TTO

M)

6"X2

0"O

PEN

ING

. 2R

EQU

IRED

Page 42: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

38

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT

: ST

EEL

TO C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

CPA

CER

TIFI

EDW

EIG

HT:

81,

065l

bs/3

6,77

0kg

(TO

P)

8

1,62

5lbs

/37,

025k

g (B

OTT

OM

)

9145

[360

"]20

3[8

"] (T

YP)

2745

[108

1/8

"]20

3[8

"]

203

[8"]

3660[144 1/8"]

3607[142"]

77 [3"]

9145

[360

"]

203[8"](TYP.)

3660

[144

1/8

"]

12"x

4" O

PEN

ING

(TYP

.)

203[8"](TYP.)20

3[8

"](TY

P.)

152

[6"](

TYP.

)

3230[127 1/8"]

4" P

VCIN

LET

4" P

VCO

UTL

ET

3150[124"]

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30

SEC

TIO

N B

SCAL

E:1/

30

2'x2

' OPE

NIN

G(T

YP.)

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.R

EIN

FOR

CEM

ENT

TO C

ON

FOR

M T

OC

SA-G

30.1

2-40

0Pa

3.BU

RIA

L D

EPTH

: 30"

4.R

EIN

FOR

CEM

ENT

TAN

K: 2

0M @

150

O/C

BO

TH W

AYS

LID

: 20M

@ 1

50 O

/C B

OTH

WAY

S

GEN

ERA

L N

OTE

S:

1804[71"]

1804[71"]

610[24"]

KNO

CKO

UT

PAN

EL

91,0

00 L

ITR

ES T

O R

OO

F20

,000

IMPE

RIA

L G

ALLO

NS

4" P

VC IN

LET

20,0

00 IM

PER

IAL

GAL

LON

/ 90

,900

LIT

RES

DA

TE:

JAN

/ 20

18

DR

AW

N B

Y:S.

RIM

LAN

D

MA

NU

FAC

TUR

ED:

OTT

AWA,

ON

1-80

0-65

5-34

30

9090

0 LI

TRES

SIN

GLE

2000

0 IM

PER

IAL

GA

LLO

NC

HAM

BER

838

[33"

]6"

X20"

OPE

NIN

G. 2

REQ

UIR

ED

Page 43: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

39

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

EAN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FTIS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

WEI

GH

T: 3

4,87

0lbs

/ 15

,820

kgC

PA C

ERTI

FIED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

4" IN

LET

CAS

T-A-

SEAL

402

SEC

TIO

N A

SCAL

E:1/

50

2527[99 1/2"]

2235[88"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

502527

[99 1/2"]

2591

[102

"]50

55[1

99"]

108[4 1/4"]

127

[5"] 86

[3 3

/8"]

4" IN

LET

CAS

T-A-

SEAL 40

2

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

610[24"]

2406[94 3/4"]

DR

Y H

YDR

ANT

DIX

ON

-dfh

914

0-60

010

0mm

VEN

T

TOTA

L C

APA

CIT

Y: 2

5,85

3 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

2275

0 LI

TRES

5000

IMPE

RIA

L G

ALL

ON

*SIN

GLE

FIR

E W

ATER

TAN

K*

4" P

VC P

IPE

Page 44: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

40

1.C

AS 6

03- C

AST

CLO

SE A

S PO

SSIB

LE T

O T

HE

BOTT

OM

OF

TAN

K

2.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

T TH

E JO

INTS

3. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TR

UC

KS

4.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

5.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT IS

REQ

UIR

ED

6.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PR

OPE

R L

IFTI

NG

EQ

UIP

MEN

T (I.

E. S

PREA

DER

BAR

)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N A

SCAL

E:1/

60

2527[99 1/2"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

60

5055

[199

"]

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R 2

REQ

. PER

UN

IT

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

100m

m V

ENT

128[5"]

4" IN

LET

CAS

T-A-

SEAL

402

CAS

603

FO

R8"

I.D

. SD

R 3

5

2591[102"]

128[5"]

5055

[199

"]12

7[5

"]

1352

[53

1/4"

]

2235[88"]

4" IN

LET

CAS

T-A-

SEAL

402

2591

[102

"]25

91[1

02"]

108[4 1/4"]

86[3

3/8

"]127

[5"]

2527[99 1/2"]

4" IN

LET

CAS

T-A-

SEAL

402

CAS

603

FO

R8"

I.D

. SD

R 3

5

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R 2

REQ

. PER

UN

IT

CAS

603

FO

R8"

I.D

. SD

R 3

5

1352

[53

1/4"

]

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

100m

m V

ENT

610[24"]

2406[94 3/4"]

410[16 1/8"]

1352

[53

1/4"

]

NO

TE 1

2351

[92

1/2"

]

TAN

K 1

TAN

K 2

TAN

K 1

TAN

K 2

TAN

K 2

WEI

GH

T: 3

4,87

0lbs

/ 15

,820

kgC

PA C

ERTI

FIED

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

PaD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

T

OTA

L C

APA

CIT

Y: 2

5,85

3 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

PER

TAN

K

2275

0 LI

TRES

5000

IMPE

RIA

L G

ALL

ON

*2-N

ESTE

D F

IRE

WAT

ER T

ANKS

*

4" P

VC P

IPE

Page 45: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

41

1.U

NIT

S AR

E SE

ALED

W

ITH

BU

TYL

TAPE

AT

THE

JOIN

TS

2.D

ELIV

ERY

IS

MAD

E BY

CR

ANE-

EQU

IPPE

D T

RU

CKS

3.EX

CAV

ATIO

N

MU

ST

BE

REA

DY,

SAFE

AN

D

ACC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

O

FTH

E TR

UC

K.

4.M

IN

OVE

RH

EAD

C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN

FIR

M

SOIL

AW

AY

FRO

M

ANY

VEH

ICU

LAR

TR

AFFI

C

GEN

ERA

L N

OTE

S:

WEI

GH

T: 4

0,90

5lbs

/ 18

,555

kgC

PA C

ERTI

FIED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

4" IN

LET

CAS

T-A-

SEAL

402

SEC

TIO

N A

SCAL

E:1/

50

3188[125 1/2"]

2896[114"]

108[4 1/4"]

108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

50

3188[125 1/2"]

108[4 1/4"]

127

[5"] 86

[3 3

/8"]

4" IN

LET

CAS

T-A-

SEAL

402

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2 R

EQU

IRED

(TYP

.)

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

610[24"]

3067[120 3/4"]

DR

Y H

YDR

ANT

DIX

ON

-dfh

914

0-60

010

0mm

VEN

T

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

TOTA

L C

APA

CIT

Y: 3

3,91

8 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

3000

0 LI

TRES

6600

IMPE

RIA

L G

ALL

ON

*SIN

GLE

FIR

E W

ATER

TAN

K*

4" P

VC P

IPE

Page 46: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

42

1.C

AS 6

03- C

AST

CLO

SE A

S PO

SSIB

LE T

O T

HE

BOTT

OM

OF

TAN

K

2.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

T TH

E JO

INTS

3. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TR

UC

KS

4.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FRO

M T

HE

REA

R O

F TH

E TR

UC

K.

5.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT IS

REQ

UIR

ED

6.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PR

OPE

R L

IFTI

NG

EQ

UIP

MEN

T (I.

E.SP

REA

DER

BAR

)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

2591[102"]

TOP

VIEW

SCAL

E:1/

60

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R2

REQ

. PER

UN

IT

4" P

VCIN

LET

SEC

TIO

N A

SCAL

E:1/

60108[4 1/4"]

SEC

TIO

N B

SCAL

E:1/

60

4" IN

LET

CAS

T-A-

SEAL 40

2

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

610[24"]

DR

Y H

YDR

ANT

DIX

ON

-dfh

914

0-60

0

100m

m V

ENT

4" IN

LET

CAS

T-A-

SEAL

402

100m

m V

ENT

CAS

603

FO

R8"

I.D

. SD

R 3

5

CAS

603

FO

R8"

I.D

. SD

R 3

5

CAS

603

FO

R8"

I.D

. SD

R 3

5

TAN

K 1

TAN

K 2

1352

[53

1/4"

]13

52[5

3 1/

4"]

5055

[199

"]

2351

[92

1/2"

]

127

[5"]

128[5"]

128[5"]

TAN

K 1

TAN

K 2

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R2

REQ

. PER

UN

IT

1352

[53

1/4"

]

3188[125 1/2"]

410[16 1/8"]

2896[114"]

5055

[199

"]

3188[125 1/2"]

108[4 1/4"]

NO

TE 1

2591

[102

"]

3188[125 1/2"]

108[4 1/4"]

127

[5"]

87[3

3/8

"]

TAN

K 2

WEI

GH

T: 4

0,90

5lbs

/ 18

,555

kgC

PA C

ERTI

FIED

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

TOTA

L C

APA

CIT

Y: 3

3,91

8 LI

TRES

TO

UN

DER

SID

E O

F C

HAM

BER

LID

P

ER T

ANK

3000

0 LI

TRES

6600

IMPE

RIA

L G

ALL

ON

*2-N

ESTE

D F

IRE

WAT

ER T

ANKS

*

4" P

VC P

IPE

Page 47: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

43

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N A

SCAL

E:1/

60SE

CTI

ON

BSC

ALE:

1/60

7315

[288

"]3048[120"]

3048

[120

"]

1524[60"]

1473[58"]

2997[118"]

2997[118"]

7315

[288

"]

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.M

AXIM

UM

BU

RIA

L D

EPTH

=

1 M

ETR

E IN

FIR

M S

OIL

AW

AY F

RO

M A

NY

VEH

ICU

LAR

TRAF

FIC

GEN

ERA

L N

OTE

S:

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

2R

EQU

IRED

(TYP

.)

203 [8"]

203

[8"]

203

[8"]

2616[103"]

4" IN

LET

CAS

T-A-

SEAL

402

170[6 3/4"]

2642[104"]

610[24"]

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

100m

m V

ENT

DR

Y H

YDR

ANT

DIX

ON

-dfh

914

0-60

0

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

2799[110 1/4"]

4550

0 LI

TRES

1000

0 IM

PER

IAL

GA

LLO

N

*SIN

GLE

FIR

E W

ATER

TAN

K*

4" P

VC P

IPE

10,0

00 IM

PER

IAL

GAL

LON

/ 45

,500

LIT

RES

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

MEE

TS G

30.1

4-M

1983

CSA

APP

RO

VED

WEI

GH

T: 4

7,00

0lbs

/ 21

,000

kg (T

OP)

4

7,00

0lbs

/ 21

,000

kg (B

OTT

OM

)

Page 48: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

44

TOP

VIEW

SCAL

E:1/

80

SEC

TIO

N A

SCAL

E:1/

80

SEC

TIO

N B

SCAL

E:1/

80

1.C

AS 6

03 -

CAS

T C

LOSE

AS

POSS

IBLE

TO

THE

BOTT

OM

OF

TAN

K

2.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

3.M

AXIM

UM

BU

RIA

L D

EPTH

=

1 M

ETR

E IN

FIR

M S

OIL

AW

AY F

RO

M A

NY

VEH

ICU

LAR

TRAF

FIC

GEN

ERA

L N

OTE

S:

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R2

REQ

. PER

TAN

K

610[24"]

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

100m

m V

ENT

DR

Y H

YDR

ANT

DIX

ON

-dfh

914

0-60

0

3048[120"] 203

[8"]

7315

[288

"]

2997[118"]

2616[103"]

7315

[288

"]

2799[110 1/4"]

3048

[120

"]1473[58"]

170[6 5/8"]

170[6 3/4"]

1524[60"]

2997[118"]

3048

[120

"]

1352

[53

1/4"

]13

52[5

3 1/

4"]

4611

[181

1/2

"]

4" IN

LET

CAS

T-A-

SEAL

402

203

[8"]

100m

m V

ENT

CAS

603

FO

R8"

I.D

. SD

R 3

5

CAS

603

FO

R8"

I.D

. SD

R 3

5

TAN

K 2

TAN

K 1

NO

TE 1

TAN

K 1

TAN

K 2

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R2

REQ

. PER

TAN

K

1352

[53

1/4"

]

410[16 1/8"]

TAN

K 1

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

4550

0 LI

TRES

1000

0 IM

PER

IAL

GA

LLO

N

*2-N

ESTE

D F

IRE

WAT

ER T

ANKS

*

4" IN

LET

CAS

T-A-

SEAL

402

4" P

VC P

IPE

CAS

603

FO

R8"

I.D

. SD

R 3

5

10,0

00 IM

PER

IAL

GAL

LON

/ 45

,500

LIT

RES

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT:

MEE

TS G

30.1

4-M

1983

CSA

APP

RO

VED

WEI

GH

T: 4

7,00

0lbs

/ 21

,000

kg (T

OP)

4

7,00

0lbs

/ 21

,000

kg (B

OTT

OM

)

PER

TAN

K

Page 49: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

45

9145

[360

"]20

3[8

"]

3660[144 1/8"]

3607[142"]

77 [3"]

9145

[360

"]

206[8 1/8"](TYP.)

3660

[144

1/8

"]

203[8"](TYP.)20

3[8

"](TY

P.)

152

[6"](

TYP.

)

3230[127 1/8"]

4" P

VCIN

LET

20,0

00 IM

PER

IAL

GAL

LON

/ 91

,000

LIT

RES

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

TUFF

- TIT

E 12

" X 2

4"W

ITH

CO

VER

3 R

EQU

IRED

TOP

VIEW

SCAL

E:1/

60

SEC

TIO

N A

SCAL

E:1/

60

SEC

TIO

N B

SCAL

E:1/

60

1.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

2.R

EIN

FOR

CEM

ENT

TO C

ON

FOR

M T

OC

SA-G

30.1

2-40

0Pa

3.BU

RIA

L D

EPTH

: 30"

4.R

EIN

FOR

CEM

ENT

TAN

K: 2

0M @

150

O/C

BO

TH W

AYS

LID

: 20M

@ 1

50 O

/C B

OTH

WAY

S

GEN

ERA

L N

OTE

S:

1804[71"]

1803[71"]

610[24"]

KNO

CKO

UT

PAN

EL

91,0

00 L

ITR

ES T

O R

OO

F20

,000

IMPE

RIA

L G

ALLO

NS

203

[8"]

2745

[108

1/8

"]20

3[8

"]

3391[133 1/2"]

610[24"]

12"x

4" O

PEN

ING

(TYP

.)

2'x2

' OPE

NIN

G(T

YP.)

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

9090

0 LI

TRES

2000

0 IM

PER

IAL

GA

LLO

N

*SIN

GLE

FIR

E W

ATER

TAN

K*

4" P

VC P

IPE

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT

: ST

EEL

TO C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

CPA

CER

TIFI

EDW

EIG

HT:

77,

100l

bs/3

4,97

0kg

(TO

P)

7

7,70

0lbs

/35,

244k

g (B

OTT

OM

)

838

[33"

]

6"X2

0"O

PEN

ING

. 2R

EQU

IRED

Page 50: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

46

3660[144 1/8"]

12"x

4" O

PEN

ING

(TYP

.)

20,0

00 IM

PER

IAL

GAL

LON

/ 91

,000

LIT

RES

12" X

24"

TU

FF-T

ITE

WIT

H C

OVE

R3

REQ

. PER

TAN

K

TOP

VIEW

SCAL

E:1/

90

SEC

TIO

N B

SCAL

E:1/

90

2'x2

' OPE

NIN

G(T

YP.)

1.C

AS 6

03 -

CAS

T C

LOSE

AS

POSS

IBLE

TO

TH

E BO

TTO

M O

F TH

E TA

NK

2.C

ON

CR

ETE

TO B

E 45

MPa

/6,5

00 P

.S.I.

3.R

EIN

FOR

CEM

ENT

TO C

ON

FOR

M T

O C

SA-G

30.1

2-40

0Pa

4.BU

RIA

L D

EPTH

: 30"

5.R

EIN

FOR

CEM

ENT

TAN

K: 2

0M @

150

O/C

BO

TH W

AYS

LID

: 20M

@ 1

50 O

/C B

OTH

WAY

S

GEN

ERA

L N

OTE

S:

203[8"]

9145

[360

"]91

45[3

60"]

3660

[144

1/8

"]

3607[142"]

SEC

TIO

N A

SCAL

E:1/

90

3230[127 1/8"]

3607[142"]

203

[8"]

203

[8"]

2745

[108

1/8

"]20

3[8

"]

1352

[53

1/4"

]13

52[5

3 1/

4"]

6440

[253

1/2

"]

410[16 1/8"]

CAS

603

FO

R8"

I.D

. SD

R 3

5

NO

TE 1

610[24"]

3391[133 1/2"]

1352

[53

1/4"

]

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

100m

m V

ENT

100m

m V

ENT

175m

OPE

NIN

GFO

R D

RY

HYD

RAN

TD

IXO

N-d

fh 9

140-

600

610[24"]

KNO

CKO

UT

PAN

EL

77 [3"]

4" P

VCIN

LET

CAS

603

FO

R8"

I.D

. SD

R 3

5

TAN

K 2

TAN

K 1

TAN

K 1

TAN

K 2

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

100m

m V

ENT

TAN

K 1

9090

0 LI

TRES

2000

0 IM

PER

IAL

GA

LLO

N

*2-N

ESTE

D F

IRE

WAT

ER T

ANKS

*

4" P

VC P

IPE

CAS

603

FO

R8"

I.D

. SD

R 3

5

CO

NC

RET

E: 4

5MPa

/ 6,

500P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

MEE

TS C

AN/C

SA-B

66-0

0R

EIN

FOR

CEM

ENT

: ST

EEL

TO C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

CPA

CER

TIFI

EDW

EIG

HT:

81,

065l

bs/3

6,77

0kg

(TO

P)

81,

625l

bs/3

7,02

5kg

(BO

TTO

M)

P

ER T

ANK

838

[33"

]

6"X2

0"O

PEN

ING

. 2R

EQU

IRED

Page 51: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

47

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N A

SCAL

E:1/

30SE

CTI

ON

BSC

ALE:

1/30

UN

IT W

EIG

HT:

11,

620

lbs

CPA

CER

TIFI

ED

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

76[3

"] (T

YP.)

648[25 1/2"]

76 [3"]

76[3"]

1000

IMPE

RIA

L G

ALLO

N /

4,50

0 LI

TRES

2972

[117

"]2184[86"]

1295[51"]

76[3"]

CO

NC

RET

E: 3

5MPa

at 2

8 da

ys /

5000

PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

2082

[82"

]28

70[1

13"]

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

FEB/

2018

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

711

[28"

]49

5[1

9 1/

2"]

203

[8"]

203

[8"]

711

[28"

]49

5[1

9 1/

2"]

508[20"]

254[10"]

SEE

DET

AIL

1TO

ILET

RIS

ERO

PEN

ING

2 R

EQ.

6" O

PEN

ING

FOR

VEN

T2

REQ

.

DET

AIL

1: T

OIL

ET R

ISER

OPE

NIN

GSC

ALE:

1/16

214[8 7/16"]

108[4 1/4"]

214[8 7/16"]

537[21 1/8"]

429

[16

7/8"

]

R214

[R8 7

/16"]

PRIV

Y 10

00 L

OW

WO

OD

76[3"]

Page 52: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

48

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

LTA

PE A

T TH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BYC

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAFE

AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PRO

PER

LIF

TIN

G E

QU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

IL A

WAY

FR

OM

AN

YVE

HIC

ULA

R T

RAF

FIC

GEN

ERA

L N

OTE

S:

WEI

GH

T: 2

7,18

0lbs

/ 12

,330

kg

CPA

CER

TIFI

ED

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 12

" CO

VER

WIT

H 1

2"X1

2" R

ISER

4" P

VC C

OU

PLER

TO C

ON

NEC

T4"

PIP

E

SEC

TIO

N A

SCAL

E:1/

50

1499[59"]

108[4 1/4"]

127[5"]

SEC

TIO

N B

SCAL

E:1/

501499[59"]

2591

[102

"]50

55[1

99"]

TUFF

TIT

E 12

" CO

VER

WIT

H 1

2"X1

2" R

ISER

108[4 1/4"]

87[3

3/8

"]

127

[5"]

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: S

TEEL

TO

CSA

CAN

A23.

1 /A

23.3

G30

.18

Fy=4

00M

Pa

TUFF

TIT

E 12

" CO

VER

WIT

H 1

2"X1

2" R

ISER

305[12"]

305

[12"

]86

4[3

4"]

4" P

VC C

OU

PLER

TO C

ON

NEC

T4"

PIP

E

305[12"]

DET

AIL

1: T

OIL

ET R

ISER

OPE

NIN

GSC

ALE:

1/16

572

[22

1/2"

]

214[8 7/16"]

108[4 1/4"]

214[8 7/16"]

537[21 1/8"]

429

[16

7/8"

]

521[20 1/2"]

1182

[46

1/2"

]

521[20 1/2"]

R214

[R8 7

/16"]

SEE

DET

AIL

1TO

ILET

RIS

ER O

PEN

ING

2 R

EQ.

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

PRIV

Y 25

00 W

OO

D2,

500

IMPE

RIA

L G

ALLO

N /

11,3

65 L

ITR

ESD

ATE

:

Page 53: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

49

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

T TH

E JO

INTS

2.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

3.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT IS

REQ

UIR

ED

4.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PR

OPE

R L

IFTI

NG

EQ

UIP

MEN

T (I.

E. S

PREA

DER

BAR

)

5.SC

HEM

ATIC

ON

LY (F

UR

THER

DET

AIL

UPO

N R

EQU

EST)

6.M

AXIM

UM

BU

RIA

L D

EPTH

=30"

GEN

ERA

L N

OTE

S:

WEI

GH

T:TO

P: 1

6,00

0lbs

/7,2

50kg

BOTT

OM

: 16,

000l

bs/7

,250

kgC

SA A

PPR

OVE

D3,

000

IMPE

RIA

L G

ALLO

N /

13,6

50 L

ITR

ES

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: M

EETS

G30

.14-

M19

83

SEC

TIO

N A

SCAL

E:1/

50

TOP

VIEW

SCAL

E:1/

50

SEC

TIO

N B

SCAL

E:1/

50

4876

[192

"]

1803[71"]

102

[4"]

4876

[192

"]2591[102"]

2591

[102

"]

152[6"]

152 [6"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

102

[4"]

102[4"]

1499[59"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

4190

[165

"]

686

[27"

]

2095

[82

1/2"

]

529[20 7/8"]

550

[21

5/8"

]55

0[2

1 5/

8"]

529[20 7/8"]

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

550

[21

5/8"

]68

6[2

7"]

400

[15

3/4"

]

102

[4"]

152[6"]

542

[21

3/8"

]

407[16"]

356m

OPE

NIN

GFO

R V

ENT

2 R

EQU

IRED

356m

OPE

NIN

GFO

R V

ENT

2 R

EQU

IRED

1250[49 1/4"]

1339[52 3/4"]

1274

[50

1/8"

]55

0[2

1 5/

8"]

1274

[50

1/8"

]

1274

[50

1/8"

]

542

[21

3/8"

]12

" x 1

6" T

UFF

-TIT

ER

ISER

WIT

H C

OVE

R

2-20

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDIN

OPE

NIN

GSE

E D

ETAI

L 1

50 [2"]

1274

[50

1/8"

]

2-20

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDIN

OPE

NIN

GSE

E D

ETAI

L 2

DET

AIL

1: T

OIL

ET U

NIT

PLA

NSC

ALE:

1/1

6D

ETAI

L 2:

TO

ILET

UN

IT S

ECTI

ON

SCAL

E: 1

/16

124[4 7/8"]

124[4 7/8"]

124[4 7/8"]

50 [2"]

372

[14

5/8"

]

451

[17

3/4"

]

124

[4 7

/8"]

124

[4 7

/8"]

124

[4 7

/8"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

2-20

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDO

N C

ENTE

RIN

OPE

NIN

G

NO

TCH

TO

ILET

RIS

ER T

OAC

CO

MM

OD

ATE

2-ST

AIN

LESS

STEE

L BA

RS

2-20

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDO

N C

ENTE

RIN

OPE

NIN

G

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

PRIV

Y 30

00 W

OO

D

WO

OD

STR

UC

TUR

E

WO

OD

STR

UC

TUR

E

WO

OD

STR

UC

TUR

E

*CO

NC

RET

E BU

ILD

ING

OPT

ION

S AV

AILA

BLE*

Page 54: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

50

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

T TH

E JO

INTS

2.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

3.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT IS

REQ

UIR

ED

4.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PR

OPE

R L

IFTI

NG

EQ

UIP

MEN

T (I.

E. S

PREA

DER

BAR

)

5.SC

HEM

ATIC

ON

LY (F

UR

THER

DET

AIL

UPO

N R

EQU

EST)

6.M

AXI

MU

M B

UR

IAL

DEP

TH=3

0"

GEN

ERA

L N

OTE

S:

WEI

GH

T:TO

P: 1

9,36

5lbs

/8,7

84kg

BOTT

OM

: 19,

365l

bs/8

,784

kgC

SA A

PPR

OVE

D4,

000

IMPE

RIA

L G

ALLO

N /

19,0

00 L

ITR

ES S

EPTI

C

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: M

EETS

G30

.14-

M19

83

SEC

TIO

N A

SCAL

E:1/

50

TOP

VIEW

SCAL

E:1/

50

SEC

TIO

N B

SCAL

E:1/

50

4876

[192

"]

2180[85 7/8"]

102

[4"]

4876

[192

"]

2591[102"]

2591

[102

"]

152[6"]

152 [6"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

102

[4"]

102[4"]

1876[73 7/8"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

4190

[165

"]

686

[27"

]

2095

[82

1/2"

]

529[20 7/8"]

550

[21

5/8"

]55

0[2

1 5/

8"]

529[20 7/8"]

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

550

[21

5/8"

]68

6[2

7"]

400

[15

3/4"

]

102

[4"]

152[6"]

542

[21

3/8"

]

407[16"]

310m

OPE

NIN

GFO

R V

ENT

2 R

EQU

IRED

310m

OPE

NIN

GFO

R V

ENT

2 R

EQU

IRED

1250[49 1/4"]

1339[52 3/4"]

1274

[50

1/8"

]55

0[2

1 5/

8"]

1274

[50

1/8"

]

1274

[50

1/8"

]

542

[21

3/8"

]12

" x 1

6" T

UFF

-TIT

ER

ISER

WIT

H C

OVE

R

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDIN

OPE

NIN

GSE

E D

ETAI

L 1

50 [2"]

1274

[50

1/8"

]

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDIN

OPE

NIN

GSE

E D

ETAI

L 2

DET

AIL

1: T

OIL

ET U

NIT

PLA

NSC

ALE:

1/1

6D

ETAI

L 2:

TO

ILET

UN

IT S

ECTI

ON

SCAL

E: 1

/16

124[4 7/8"]

124[4 7/8"]

124[4 7/8"]

50 [2"]

372

[14

5/8"

]

451

[17

3/4"

]

124

[4 7

/8"]

124

[4 7

/8"]

124

[4 7

/8"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDO

N C

ENTE

RIN

OPE

NIN

G

NO

TCH

TO

ILET

RIS

ER T

OAC

CO

MM

OD

ATE

2-ST

AIN

LESS

STEE

L BA

RS

PRO

VID

ED B

YO

NTA

RIO

PAR

KS

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDO

N C

ENTE

RIN

OPE

NIN

G

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

PRIV

Y 40

00 W

OO

D*C

ON

CR

ETE

BUIL

DIN

G O

PTIO

NS

AVAI

LABL

E*

WO

OD

STR

UC

TUR

E

WO

OD

STR

UC

TUR

E

Page 55: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

51

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

T TH

E JO

INTS

2.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

D A

CC

ESSI

BLE

FOR

UN

LOAD

ING

FR

OM

TH

E R

EAR

OF

THE

TRU

CK.

3.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT IS

REQ

UIR

ED

4.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PR

OPE

R L

IFTI

NG

EQ

UIP

MEN

T (I.

E. S

PREA

DER

BAR

)

5.SC

HEM

ATIC

ON

LY (F

UR

THER

DET

AIL

UPO

N R

EQU

EST)

6.M

AXI

MU

M B

UR

IAL

DEP

TH=3

0"

GEN

ERA

L N

OTE

S:

WEI

GH

T:TO

P: 2

0,00

0lbs

/9,0

70kg

BOTT

OM

: 20,

000l

bs/9

,070

kgC

SA A

PPR

OVE

D5,

000

IMPE

RIA

L G

ALLO

N /

22,7

30 L

ITR

ES S

EPTI

C

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%M

EETS

CAN

/CSA

-B66

-00

REI

NFO

RC

EMEN

T: M

EETS

G30

.14-

M19

83

SEC

TIO

N A

SCAL

E:1/

60

TOP

VIEW

SCAL

E:1/

50

SEC

TIO

N B

SCAL

E:1/

60

4876

[192

"]

2565[101"]

4876

[192

"]2591[102"]

2591

[102

"]

152[6"]

152 [6"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

102

[4"]

102[4"]

2261[89"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

4190

[165

"]

686

[27"

]

2095

[82

1/2"

]

529[20 7/8"]

550

[21

5/8"

]55

0[2

1 5/

8"]

529[20 7/8"]

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

400

[15

3/4"

]

542

[21

3/8"

]

407[16"]

310m

OPE

NIN

GFO

R V

ENT

2 R

EQU

IRED

310m

OPE

NIN

GFO

R V

ENT

2 R

EQU

IRED

1250[49 1/4"]

1339[52 3/4"]

1274

[50

1/8"

]

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDIN

OPE

NIN

GSE

E D

ETAI

L 1

50 [2"]

1274

[50

1/8"

]

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDIN

OPE

NIN

GSE

E D

ETAI

L 2

DET

AIL

1: T

OIL

ET U

NIT

PLA

NSC

ALE:

1/1

6D

ETAI

L 2:

TO

ILET

UN

IT S

ECTI

ON

SCAL

E: 1

/16

124[4 7/8"]

124[4 7/8"]

124[4 7/8"]

50 [2"]

372

[14

5/8"

]

451

[17

3/4"

]

124

[4 7

/8"]

124

[4 7

/8"]

124

[4 7

/8"]

372m

HO

LE IN

CO

NC

. SLA

B TO

PFO

R T

OIL

ET2

REQ

UIR

ED

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDO

N C

ENTE

RIN

OPE

NIN

G

NO

TCH

TO

ILET

RIS

ER T

OAC

CO

MM

OD

ATE

2-ST

AIN

LESS

STEE

L BA

RS

PRO

VID

ED B

YO

NTA

RIO

PAR

KS

2-19

mm

Ø S

T. S

TEEL

CAS

T IN

PLA

CE

BAR

SEQ

UAL

LY S

PAC

EDO

N C

ENTE

RIN

OPE

NIN

G

12" x

16"

TU

FF-T

ITE

RIS

ER W

ITH

CO

VER

102

[4"]

152[6"]

550

[21

5/8"

]12

74[5

0 1/

8"]

542

[21

3/8"

]12

74[5

0 1/

8"]

550

[21

5/8"

]68

6[2

7"]

102

[4"] DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

O

TTAW

A, O

N

1-8

00-6

55-3

430

PRIV

Y 50

00 W

OO

D*C

ON

CR

ETE

BUIL

DIN

G O

PTIO

NS

AVAI

LABL

E*

WO

OD

STR

UC

TUR

E

WO

OD

STR

UC

TUR

E

Page 56: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

52

SEC

TIO

N A

SCAL

E:1/

30

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N B

SCAL

E:1/

30

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

UN

IT W

EIG

HT:

10,2

30 lb

s / 4

,650

KG

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

650

IMPE

RIA

L G

ALLO

N /

3,00

0 LI

TRES

OPT

IMU

M F

LOW

RAT

E: 3

6 L/

MIN

UTE

MO

DEL

65O

ILIN

TER

CEP

TOR

1676[66"]

DIA

M. [

4"]

3 R

EQU

IRED

(TYP

)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

PIPE

4" P

VC

OPE

NIN

G 8

" x 4

"

3" D

IAM

ETER

PVC

PIP

ING

FOR

VEN

T

76[3"]

1371[54"]

1676[66"]

76[3

"](TY

P.)

1321[52"]

102 [4"]

76[3

"](TY

P.)

178[7"](TYP.)

3" D

IAM

ETER

PVC

PIP

ING

FOR

VEN

T

356[14"]

200[7 7/8"]

432[17"]

PIPE

3" P

VCVE

NT

PIPE

4" P

VC

2286

[90"

]1524[60"]

3" D

IAM

ETER

VEN

T 4

REQ

UIR

ED

CO

NC

RET

E: 3

5MPa

/ 5,

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23.

1 / A

23.3

. G30

.18

Fy=4

00M

PaD

ATE

:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

Page 57: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

53

SEC

TIO

N A

SCAL

E:1/

30

TOP

VIEW

SCAL

E:1/

30

SEC

TIO

N B

SCAL

E:1/

30

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

4" O

UTL

ETC

AST-

A-SE

AL 4

02

4" I

NLE

TC

AST-

A-SE

AL 4

02

UN

IT W

EIG

HT:

11,3

90 lb

s / 5

,170

KG

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

960

IMPE

RIA

L G

ALLO

N /

4,40

0 LI

TRES

OPT

IMU

M F

LOW

RAT

E: 5

3 L/

MIN

UTE

MO

DEL

100

OIL

INTE

RC

EPTO

R

DIA

M. [

4"]

3 R

EQU

IRED

(TYP

)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

PIPE

4" P

VC

OPE

NIN

G 3

0" x

5"

3" D

IAM

ETER

VEN

T

3" D

IAM

ETER

VEN

T4

REQ

UIR

ED

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

76[3

"](TY

P.)

127[5"]

200[7 7/8"]

457[18"]

76[3"](TYP.)

1359[53 1/2"]

1309[51 1/2"]

1664[65 1/2"]

533[21"]

203[8"]

102[4"]

76[3

"](TY

P.)

2540

[100

"]

1834[72 1/4"]

CO

NC

RET

E: 3

5MPa

/ 5,

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23.

1 / A

23.3

. G30

.18

Fy=4

00M

Pa

1664[65 1/2"]

SAN

ITAR

Y TY

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

Page 58: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

54

SEC

TIO

N A

SCAL

E:1/

40

TOP

VIEW

SCAL

E:1/

40

SEC

TIO

N B

SCAL

E:1/

40

10M

LIF

TIN

GAN

CH

OR

.4

REQ

UIR

ED (T

YP)

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

TTH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TRU

CKS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

F TH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT I

SR

EQU

IRED

5.AL

L U

NIT

S M

UST

BE

H

AND

LED

W

ITH

PRO

PER

LI

FTIN

G

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

INFI

RM

SO

IL A

WAY

FR

OM

AN

Y VE

HIC

ULA

RTR

AFFI

C

GEN

ERA

L N

OTE

S:

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

OPT

ION

AL IN

LET

4" P

VC P

OLY

SEAL

4" O

UTL

ETC

AST-

A-SE

AL 4

02

4" IN

LET

CAS

T-A-

SEAL

402

2553[100 1/2"]

3213

[126

1/2

"]

1346[53"]

1601[63"]

1296[51"]

UN

IT W

EIG

HT:

15,4

85 lb

s / 7

,025

KG

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

1,55

0 IM

PER

IAL

GAL

LON

/ 7,

000

LITR

ESO

PTIM

UM

FLO

W R

ATE:

86

L/M

INU

TE

MO

DEL

155

OIL

INTE

RC

EPTO

R

76[3"](TYP.)

1601[63"]

76[3

"](TY

P.)

DIA

M. [

4"]

3 R

EQU

IRED

(TYP

)

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

PIPE

4" P

VC

76[3

"](TY

P.)

457[18"]

127[5"]

102[4"]

OPE

NIN

G 3

0" x

5"

76[3"] (TYP.)

3" P

VC P

IPIN

GFO

R V

ENT

24" x

6" T

UF-

TITE

RIS

ER W

ITH

CO

VER

3 R

EQU

IRED

10M

LIF

TIN

GAN

CH

OR

4 R

EQU

IRED

(TYP

)

3" P

VC P

IPIN

GFO

R V

ENT

4 R

EQU

IRED

3" P

VC P

IPIN

GFO

R V

ENT

4 R

EQU

IRED

140[5 1/2"]

CO

NC

RET

E: 3

5MPa

/ 5,

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23.

1 / A

23.3

. G30

.18

Fy=4

00M

Pa

CO

UPL

ING

S

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

Page 59: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

55

1.U

NIT

S AR

E SE

ALED

WIT

H B

UTY

L TA

PE A

T TH

E JO

INTS

2. D

ELIV

ERY

IS M

ADE

BY C

RAN

E-EQ

UIP

PED

TR

UC

KS

3.EX

CAV

ATIO

N M

UST

BE

REA

DY,

SAF

E AN

DAC

CES

SIBL

E FO

R U

NLO

ADIN

G F

RO

M T

HE

REA

R O

FTH

E TR

UC

K.

4.M

IN O

VER

HEA

D C

LEAR

ANC

E O

F 18

FT IS

REQ

UIR

ED

5.AL

L U

NIT

S M

UST

BE

HAN

DLE

D W

ITH

PR

OPE

R L

IFTI

NG

EQU

IPM

ENT

(I.E.

SPR

EAD

ER B

AR)

6.M

AXIM

UM

BU

RIA

L D

EPTH

= 1

MET

RE

IN F

IRM

SO

ILAW

AY F

RO

M A

NY

VEH

ICU

LAR

TR

AFFI

C

7.ST

OP

VALV

E BA

LL M

UST

BE

KEPT

FR

EE O

F LO

CK

OR

SEAT

PO

SITI

ON

DU

RIN

G IN

STAL

LATI

ON

.

8.O

NC

E TH

E TA

NK

IS IN

STAL

LED

, PR

IME

WIT

H W

ATER

TO M

AIN

TAIN

A W

ATER

LEV

EL A

BOVE

STO

P VA

LVE

SEAT

PO

SITI

ON

AT

ALL

TIM

ES.

9.IF

TH

E TA

NK

IS P

UM

PED

FR

OM

TIM

E TO

TIM

E, W

ATER

MU

ST B

E AD

DED

TO

KEE

P TH

E ST

OP

VALV

E BA

LLFL

OAT

ING

.

10.IF

TH

E ST

OP

VALV

E SE

ATS

ITSE

LF IN

CLO

SEPO

SITI

ON

, REL

EASE

BY

PULL

ING

TH

E R

OPE

ATTA

CH

ED T

O T

HE

BALL

. TH

E R

OPE

CAN

BE

REA

CH

ED F

RO

M T

HE

MAN

HO

LE A

T O

UTL

ET E

ND

.

11.S

PEC

IFIC

OIL

GR

AVIT

Y .8

8 TO

.90

WH

ICH

IS T

OO

LO

WTO

FLO

AT T

HE

BALL

AN

D T

HER

EFO

RE

PREV

ENTS

OIL

FRO

M E

SCAP

ING

FR

OM

TH

E O

IL IN

TER

CEP

TOR

.

GEN

ERA

L N

OTE

S:

WEI

GH

T:17

,895

lbs

/ 8,1

20kg

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

2,50

0 IM

PER

IAL

GAL

LON

/ 11

,365

LIT

RES

MO

DEL

250

5055

[199

"]

2591[102"]

TOP

VIEW

SCAL

E:1/

50

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

3 R

EQU

IRED

(TYP

.)

100Ø

T-P

IPE

ASSE

MBL

Y

4" O

UTL

ETC

AST-

A-SE

AL 4

02

SEC

TIO

N A

SCAL

E:1/

50

1499[59"]

1149[45 1/4"]

1118 [44"]

108 [4 1/4"]

127[5"]

SEC

TIO

N B

SCAL

E:1/

50

1499 [59"]

2591

[102

"]50

55[1

99"]

TUFF

TIT

E 24

" CO

VER

WIT

H 1

2"X2

4" R

ISER

3 R

EQU

IRED

(TYP

.)

87[3

3/8

"]

127

[5"]

4" IN

LET

CAS

T-A-

SEAL

402

350 [13 3/4"]

457[18"]

3" D

IAM

ETER

VEN

T- 3

REQ

UIR

ED.3

4" C

LEAR

STO

NE

@30

0MM

RAD

IUS

ARO

UN

DPI

PE

100Ø

EN

QU

IP. O

ILST

OP

VALV

E W

/P-

TRAP

ASS

EMBL

Y.

DIA

M 4

" OPE

NIN

G.

3 R

EQU

IRED

(TYP

.)

30" x

5"

OPE

NIN

G A

TBA

SE L

EVEL

OPE

NIN

G 3

0" x

5"

AT B

ASE

LEVE

L

108[4 1/4"]

DIA

M 4

" OPE

NIN

G.

3 R

EQU

IRED

(TYP

.)

3" D

IAM

ETER

VEN

T.3

REQ

UIR

ED

600[23 5/8"]

CH

AMFE

RED

ED

GES

AT B

ASE

ON

INTE

RIO

R

170[6 3/4"]

380[15"]

POLY

SEAL

WIT

HFL

ANG

E

CO

NC

RET

E: 3

5MPa

/ 5,

000P

SIA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23.

1 / A

23.3

. G30

.18

Fy=4

00M

Pa

3" D

IAM

ETER

VEN

T.3

REQ

UIR

ED

4" IN

LET

CAS

T-A-

SEAL

402

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

OIL

INTE

RC

EPTO

R

Page 60: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

56

TOP

VIEW

SCAL

E:1/

16

CPA

CER

TIFI

EDM

EETS

CSA

-BB6

-00

DIS

TRIB

UTI

ON

BO

XES

610

[24"

]

51[2"]

381[15"]

432[17"]

914

[36"

]

SEC

TIO

N A

SCAL

E:1/

16SE

CTI

ON

BSC

ALE:

1/16

TOP

VIEW

SCAL

E:1/

16

SEC

TIO

N A

SCAL

E:1/

16SE

CTI

ON

BSC

ALE:

1/16

610

[24"

]30

5[1

2"]

51[2"]

381[15"]

LAR

GE

DIS

TRIB

UTI

ON

BO

XSM

ALL

DIS

TRIB

UTI

ON

BO

X

432[17"]

1 IN

LET

- 15

OU

TLET

1 IN

LET

- 7 O

UTL

ET

CO

NC

RET

E: 3

5MPa

/500

0PSI

AIR

EN

TRA

INM

ENT:

6-8

%R

EIN

FOR

CEM

ENT:

STE

EL T

O C

SA C

ANA2

3.1

/A23

.3 G

30.1

8 Fy

=400

MPa

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

Page 61: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

57

CO

NC

RET

E: 3

5MPa

/ 46

00PS

IA

IR E

NTR

AIN

MEN

T: 6

-8%

REI

NFO

RC

EMEN

T :

STEE

L TO

CSA

CAN

A23

.1 /

A23.

3. G

30.1

8Fy

=400

MPa

UN

IT W

EIG

HT:

LID

22"

X26"

: 132

lbs

/ 60k

gsLI

D 2

0"X2

4": 1

10lb

s / 5

0kgs

LID

32"

X32"

: 214

lbs

/ 97k

gs

RET

RO

FIT

LID

S

RET

RO

FIT

22"X

26"

TOP

VIEW

SCAL

E:1/

16

660

[26"

]

559[22"]

16"D

IA. X

6"

TUF-

TITE

RIS

ERW

ITH

CO

VER

CR

OSS

SEC

TIO

NSC

ALE:

1/16

660

[26"

]40

6[1

6"] I

.D.

154[6"]

76[3"]

RET

RO

FIT

32"X

32"

TOP

VIEW

SCAL

E:1/

20C

RO

SS S

ECTI

ON

SCAL

E:1/

16

813

[32"

]40

6[1

6"] I

.D.

152[6"]

76[3"]

2 - 5

1 16" G

ALV.

LIF

TIN

GH

OO

K

2 - 5

1 16" G

ALV.

LIF

TIN

GH

OO

K

813

[32"

]

813[32"]

76[3"]

16"D

IA. X

6"

TUF-

TITE

RIS

ERW

ITH

CO

VER

610

[24"

]

508[20"]

16"D

IA. X

6"

TUF-

TITE

RIS

ERW

ITH

CO

VER

2 - 5

1 16" G

ALV.

LIF

TIN

GH

OO

KTO

P VI

EWSC

ALE:

1/16

610

[24"

]

406

[16"

]

154[6"]

76[3"]

CR

OSS

SEC

TIO

NSC

ALE:

1/16

RET

RO

FIT

20"X

24"

DA

TE:

DR

AW

N B

Y:S.

RIM

LAN

D

JAN

/201

8

MA

NU

FAC

TUR

ED:

B

RO

OKL

IN, O

N

1-8

00-6

55-3

430

Page 62: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

58

Aluminum Tank Accessories Available on Request

Drip Proof Access Doors

Standard Opening Sizes – 36 x 36 30 x 30 24 x 24

Custom size Openings and Heights Available on Special Order

Flush Mount Access Doors

Standard Opening Sizes – 36 x 36 32 x 35 30 x 21

Custom size Openings on Special Order

Access Ladders

Non-Slip Aluminum Rungs on 12” Centers

Order to Required Height

Page 63: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

60

905-655-3311 1-800-655-3430905-655-3847

BROOKLIN OFFICET:F:

905-895-2373 1-888-407-6443905-898-3264

NEWMARKET OFFICET:F:

[email protected]

705-789-2338 1-800-264-3302705-789-9829

HUNTSVILLE /HALIBURTON OFFICET:F:

[email protected]@brooklin.com

Page 64: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

61

Warranty Policy Brooklin Concrete Products warrants its product to be free of defects in material and workmanship, insofar as such products are of its own manufacture and are installed and used in accordance with our recommendations and/or installation guidelines. This warranty shall be in effect for a period of one year from the day of shipment. This limited warranty covers the repair or replacement, as Brooklin Concrete Products may elect, of defective products regarding which, upon discovery of the defect, the purchaser has given immediate written notice. This warranty does not apply to any product that has been subjected to abuse or misuse, or to a product that has been altered or modified by others in any way so as, in our judgment, to affect its dependability. Brooklin Concrete Product’s liability shall be limited to the repair or replacement of its product, the cost of which shall not exceed the original purchase price of the product.

Page 65: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

62

COMPANY PRODUCT

POLICIES

905-655-3311 1-800-655-3430905-655-3847

BROOKLIN OFFICET:F:

905-895-2373 1-888-407-6443905-898-3264

NEWMARKET OFFICET:F:

[email protected]

705-789-2338 1-800-264-3302705-789-9829

HUNTSVILLE /HALIBURTON OFFICET:F:

[email protected]@brooklin.com

Page 66: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

63

Special Order Policy It is Brooklin Concrete Products’ policy to request a deposit on specially manufactured products that are produced or modified to meet the unique requirements of a specific project. A minimum deposit of 50% must be received before production of the special order will begin. This policy has been implemented to ensure the monetary involvement of a purchaser ordering a tailor‐made product is no reflection on a customer’s credit worthiness. Special order products cannot be returned for refund.

Page 67: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

64

Return/Exchange Policy Items being returned for credit or exchange must be returned within 30 days from the date of original sale. A minimum 25% restocking charge will apply to ALL returned product. In order for a credit to be issued, the product must be in its “original” condition and accompanied by the purchase receipt. Product that has been altered or damaged in any way will not be accepted, or credited. We will not refund for product that has been custom‐made (special order).

Page 68: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

65

Septic Tank Delivery Policy Many of our products are delivered to site on our self‐unloading crane trucks. Precast Concrete sections weighing in excess of 2500kg that are delivered to a jobsite on a Brooklin Concrete Products crane truck can be placed in their permanent position only if proper access is provided to a firm, flat, level and obstruction free area of sufficient size to accommodate our vehicle. The center of the placement location must be located directly to the rear of the crane truck and within 3 to 5 meters behind the vehicle. E.g. Depending on the size of the tank; sections weighing less than 2500 kg are not normally placed but are simply offloaded for others to move in to position. Our crane operators are instructed to refuse to attempt any operation that may involve a safety hazard, or may jeopardize our equipment. Please see our installation guidelines for more information. NOTE: We recommend a site inspection be arranged through the office if a contractor is unsure of the placing of a tank e.g. 2500 gallon up to 6600 gallon

Page 69: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

66

GUIDELINES & TESTING

OF TANK INSTALLATION

905-655-3311 1-800-655-3430905-655-3847

BROOKLIN OFFICET:F:

905-895-2373 1-888-407-6443905-898-3264

NEWMARKET OFFICET:F:

[email protected]

705-789-2338 1-800-264-3302705-789-9829

HUNTSVILLE /HALIBURTON OFFICET:F:

[email protected]@brooklin.com

Page 70: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

67

Installation Guidelines Site The installation site must be accessible to large heavy crane equipment. A firm, flat and level area of sufficient size to allow maneuvering room for this type of equipment must be provided. This area must be free of overhead wires, tree limbs, or other above‐grade obstructions which could affect normal crane operation. Excavation Excavation length and width should allow for a safe clearance on all sides of the precast. To minimize stress on a tank or chamber, it should be placed on a base of gravel or crushed stone, minimum 150mm thick. Soil conditions must be firm and stable.

Page 71: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

68

Soil Conditions Most of our precast tanks are designed for installation in firm stable soil. Unless designed for such use our product warranty is void where an installation involves saturated/unstable soils. Regardless of any design enhancements the precast structure must always be placed on a flat, firm supporting surface. Back Filling Back fill material must be free of boulders and large stones. Back fill must be placed in layers progressively against the four sides of the precast structure. When back filling with an excavator do not drop back fill on the precast or in to the excavation from a height greater than one meter. The wheels or tracks of back filling equipment must be kept at least one meter away from the tank or chamber. At no time should heavy equipment come in contact with any part of the precast. Compaction of fill around a tank can impose stresses sufficient to cause failure of the walls. Discretion must be used in this operation. Naturally large tanks with comparatively thin walls should be backfilled and compacted to minimize this stress.

Page 72: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

69

Joint Seal 1. The mating surfaces of the joint must be clean and dry. The lower precast section should be placed in its final position in the excavation. The joint of this section should be made clean and dry, then mastic strips of sealant applied. Ensure that the ends of each strip overlap by a minimum of 26mm as the sealant is laid around the joint. 2. Using lifting equipment that is safely adequate for the job, hoist each subsequent precast section a few feet above the ground in an open area away from the excavation. The joint surface of this section must now be inspected. A broom should be used to sweep away adherent debris. Care must be taken that the people preforming this task have ample room to maneuver and do not at any time work directly under the hanging load. Should it prove impossible to clean the joint properly in this way, the section must be safely blocked up in position to allow access from underneath. 3. Once the joint surfaces are clean, dry, free of debris and extra mastic has been applied in areas where the male or female joint might have been chipped or broken in handling, the upper section can be carefully set directly onto the lower section.

Page 73: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

70

4. Allow the structure to stand until the mastic is completely crushed in to all parts of the joint and it stops extruding from the sides. Remove the excess mastic and ensure the outer wall is clean and dry in the area 8” above and below the joint. Apply TWO COATS of mastic primer using a paint roller to the outer wall surface. (8” above and below the joint) 5. Apply the mastic membrane to the primed area making sure it is centered over the joint. The protective paper backing should be removed progressively as the mastic band is applied. Using a roller or other blunt shape, push the mastic firmly on to the primed surface rolling out any ripples or folds. 6. An overlap is necessary when joints occur in the mastic band. Apply primer to back of the section that will be overlapped approximately 12”. Place the overlapping end on to the primed section and roll in to place.

Page 74: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

71

Testing Pipe Connections Fill the tank with water to 18 inches (460mm) above the connection at the outside of the tank for a suitable period of time; usually between 2 ‐ 24 hours. If no leaks occur around the pipe in the suitable period of time, backfill around pipes and compact the soils before backfilling to the joint. Joint Fill the tank with water to 18 inches (460mm) above the joint. Observe the outside of the tank at the joint for a suitable period of time; usually 2 – 24 hours. Assembled Tank Fill the tank to the underside of the roof slab or to a point up inside the access riser. This access riser should be a one piece casting integral with or mechanically connected and sealed to the top of the tank. Note the liquid level, let stand for a suitable amount of time and then check the level.

Page 75: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

72

Caution: Filling the tank with liquid before backfilling Many of the precast tanks detailed in this catalogue rely on support from the surrounding earth, in which they are buried, to resist stress imposed by the contained liquid. It is recommended that the tank at no time be filled higher than 24 inches (600mm) above the lowest outside level of backfill.

Page 76: SEPTIC TANK SYSTEMS Product Guide...1 24" x 6" tuf-tite riser with cover 2 required top view scale:1/30 section a scale:1/30 section b scale:1/30 unit weight: 6,490lbs / 2,943kg cpa

905-655-3311 1-800-655-3430905-655-3847

BROOKLIN OFFICET:F:

905-895-2373 1-888-407-6443905-898-3264

NEWMARKET OFFICET:F:

[email protected]

705-789-2338 1-800-264-3302705-789-9829

HUNTSVILLE /HALIBURTON OFFICET:F:

[email protected]@brooklin.com

WWW.BROOKLIN.COM