September 2014 - Schaffner...ECOsine® Active with Germanischer Lloyd The power quality solution for...

4
www.myecosine.com ECOsine® Active with Germanischer Lloyd The power quality solution for marine, offshore and oil and gas September 2014

Transcript of September 2014 - Schaffner...ECOsine® Active with Germanischer Lloyd The power quality solution for...

Page 1: September 2014 - Schaffner...ECOsine® Active with Germanischer Lloyd The power quality solution for marine, offshore and oil and gas September 2014. 2 ECOsine® Active with Germanischer

www.myecosine.com

ECOsine® Active with Germanischer LloydThe power quality solution for marine, offshore and oil and gas

September 2014

Page 2: September 2014 - Schaffner...ECOsine® Active with Germanischer Lloyd The power quality solution for marine, offshore and oil and gas September 2014. 2 ECOsine® Active with Germanischer

2 ECOsine® Active with Germanischer Lloyd

ECOsine® Active with GL approval

The quality and reliability of the electrical supply is crucial to almost any application nowadays.

But it is even more crucial for systems in the marine and oil and gas sector. Achievements such

as energy efficiency, lower costs of operation, less maintenance and lower emissions have been

realized mainly with the increasing use of AC and DC electric drives. Besides the significant

benefits of these technologies, it is poor power quality due to harmonic distortion which has

become a critical safety issue. ECOsine® Active harmonic filters deliver a reliable remedy. They

provide the system with an opposing corrective current immediately, compensating harmonics,

phase shift and load-unbalance at the same time. They dynamically adapt to changing grid and

load situations, providing an optimum compensation performance at all times.

The German Lloyd approved ECOsine® Active, based on state-of-the-art power electronics

technology for active harmonic filters, fulfills all requirements for harmonic mitigation

equipment and meet the needs of oil and gas, marine and offshore applications. It reliably

ensures the fulfillment of strict harmonic standards issued by regulating bodies. Together with

the well known compact design and high reliability ECOsine® Active FN3420-100-480-3-GL and

FN3420-120-480-3-GL are the ideal choice to enable safe, reliable and enhanced performance

in versatile projects and operations in this range of challenging applications.

ECOsine® Active uses intelligent digital technology. Its flexibility is obvious, as it can be

connected to the power line on the load or grid side with numerous current transformer-

ratios. Once configured with just a few clicks, the present line current will be permanently

measured and all harmonics and phase displacements are actively compensated. To do this,

ECOsine® Active calculates the appropriate compensation currents within microseconds,

which are then generated and fed into the network. This is possible due to full digital control

and fast high performance computing.

I Offshore Production and processing

I Offshore oil and gas installations

I Offshore drilling

I Onshore production and processing

I Coastal electricity generation plants

I Seawater desalination plants

I Shipbuilding

I Leisure boats and yachts

I Cruise ships and ferries

A reliable solution for critical applications

ECOsine® Active uses intelligent digital technology

Page 3: September 2014 - Schaffner...ECOsine® Active with Germanischer Lloyd The power quality solution for marine, offshore and oil and gas September 2014. 2 ECOsine® Active with Germanischer

3ECOsine® Active with Germanischer Lloyd

Technical specifications

I Seawater desalination plants

I Shipbuilding

I Leisure boats and yachts

I Cruise ships and ferries

79(3,11) 310(12,2)

850(33,46)

275(10,81)

192(7,56)

156(6,14)

469(18,44)

461(18,14)

172(6,77) 186(7,32)

134(5,29)

320(12,6)

0 207(8,14)

271(10,67)

338(13,3)

0

198(7,79)

233(9,17)

268(10,54)

297(11,69)

61(2,41)

412(16,23)

120(4,72)253(9,96)

364(14,33)

965(38,01)

252(9,92)

1216(47,87)

201(7,92) 129(5,08)

260(10,22)

773(30,43)

35(1,38)

20(0,79)

280(11,02) 95(3,73)86(3,37)

107(4,21)

281(11,06)

B

A

32(1,26)(2x)

11(0,43) (2x)

R 11(0,43)

DETAIL BSCALE 1 : 5

Front coverpowder coatedRAL 7035

Shielded connection 1

Shielded connection 2

11(0,43)(4x)

15( 0,57) (4x)

DETAIL ASCALE 1 : 5

DATE:DESCRIPTION:REVISION: Change Request NAME: PROVE:

REVISION:

PROJECTION

all sharp edges removedpart free of burs and degreasegeneral tolerances DIN ISO 2768-m1

SCALE:

SAP-NO:

Copyright Schaffner. All rights reserved

We reserve all rights in thedocument and in the informationcontained therein. Passing onand/or communication of itscontent is not permitted without thewritten authoriziation of Schaffner

DO NOT SCALE DRAWING

11.03.14

1 1

NAME:

WEIGHT:

MATERIAL:

OFSHEET

DATE:

FINISH:

energy efficiency and reliability

SCHAFFNER

TITLE:

DWG NO:A2

DRAWN

APPROVED

QUALITY

PROVED

MANUFACTURER

30.06.1430.06.14

SchuchertKamenka

Etzel

SAP-NO.

814306, 814307 VI00

FN3420-100/120-480-3-GL

1:10

132411 A

ECOsine® Active FN 3420-100/120-480-3

Mains frequency: 50/60 Hz ± 3 HzFilter performance: Up to the 50th orderParallel operation: Up to 5 units on one set of current transformersResponse time: 300 µsOverload capability (peak value): 250 A (peak value phase current) for 10 msCooling Type: Air coolingAmbient conditions:* (EN 50178)

Pollution degree: 2; relative humidity: < 95 %, non-condensing, 3 K3 Temperature: Storage –25 °C to 55 °C, 1 K3, 1 K4 – transportation –25 °C to +70 °C, 2 K3

Interfaces: Modbus RTU (RS485), Modbus TCP/IP (Ethernet)Altitude: 1,000 m with derating up to 4,000 m, 1 %/100 mSwitching frequency: 16 kHzController topology: Digital with FFT analysisCurrent limitation: Nominal currentCurrent transformer: 50 : 5 to 50,000 : 5Protection class: IP 20Weight: 112 kg (incl. Filter RU 33092-120-3L)

Filter Type: FN 3420-100-480-3-GL FN 3420-120-480-3-GLRated comp. current (3-wire): 100 A (phase) 120 A (phase)

Mains voltage: 380 V (AC) ± 15 % … 480 V (AC) ± 10 % (GL main voltage 400 VAC)

380 V (AC) ± 15 % … 480 V (AC) ± 10 % (GL main voltage 400 VAC)

Ambient temperature: 0–40 °C, up to 55 °C with derating (2 %/K) 0–30 °C, up to 40 °C with derating 1.2 %/K, up to 55 °C with derating (2%/K)

Approvals: CE, GL CE, GL

* for further details on GL guidline please refer to the filters manual

Page 4: September 2014 - Schaffner...ECOsine® Active with Germanischer Lloyd The power quality solution for marine, offshore and oil and gas September 2014. 2 ECOsine® Active with Germanischer

09/2

014

EN

Headquarters, global innovationand development center

Schaffner GroupNordstrasse 114542 Luterbach SwitzerlandT +41 32 681 66 26 F +41 32 681 66 [email protected]

Sales and application centers

ChinaSchaffner EMC Ltd. ShanghaiT20-3, No 565 Chuangye RoadPudong New AreaShanghai 201201 T +86 21 3813 9500F +86 21 3813 9501 / [email protected]

FinlandSchaffner OySauvonrinne 19 H08500 LohjaT +358 19 35 72 [email protected]

FranceSchaffner EMC S.A.S.112, Quai de Bezons95103 ArgenteuilT +33 1 34 34 30 60F +33 1 39 47 02 [email protected]

GermanySchaffner Deutschland GmbHSchoemperlenstrasse 12B76185 KarlsruheT +49 721 56910F +49 721 [email protected]

ItalySchaffner EMC S.r.l.Via Galileo Galilei, 4720092 Cinisello Balsamo (MI)T +39 02 66 04 30 45/47F +39 02 61 23 [email protected]

JapanSchaffner EMC K.K.Mitsui-Seimei Sangenjaya Bldg. 7F1-32-12, Kamiuma, Setagaya-kuTokyo 154-0011T +81 3 5712 3650F +81 3 5712 [email protected]

SingaporeSchaffner EMC Pte Ltd.Blk 3015A Ubi Road 105-09 Kampong Ubi Industrial EstateT +65 6377 3283F +65 6377 [email protected]

SpainSchaffner EMC EspañaCalle Caléndula 93Miniparc III, Edificio EEl Soto de la MoralejaAlcobendas28109 MadridT +34 618 176 [email protected]

SwedenSchaffner EMC ABTurebergstorg 1, 6 19147 SollentunaT +46 8 5792 1121 / 22F +46 8 92 96 [email protected]

SwitzerlandSchaffner EMV AGNordstrasse 114542 LuterbachT +41 32 681 66 26F +41 32 681 66 [email protected]

TaiwanSchaffner EMV Ltd.6th Floor, No 413Rui Guang RoadNeihu DistrictTaipei City 114T +886 2 87525050F +886 2 [email protected]

ThailandSchaffner EMC Co. Ltd.Northern Region Industrial Estate67 Moo 4 Tambon Ban KlangAmphur Muang P.O. Box 14Lamphun 51000T +66 53 58 11 04F +66 53 58 10 [email protected]

UKSchaffner Ltd.5 Ashville WayMolly Millars LaneWokinghamBerkshire RG41 2PLT +44 118 9770070F +44 118 [email protected]

USASchaffner EMC Inc.52 Mayfield Avenue08837 Edison, New JerseyT +1 800 367 5566T +732 225 9533F +732 225 [email protected]/us

Schaffner MTC LLC6722 Thirlane Road24019 Roanoke, VirginiaT +276 228 7943F +276 228 7953www.schaffner-mtc.com

Schaffner Trenco LLC2550 Brookpark Road44134 Cleveland, OhioT +216 741 5282F +216 741 4860www.schaffner-trenco.com

To find your local partner withinSchaffner‘s global network, please go towww.schaffner.com

© 2014 Schaffner Group

The content of this document has been carefully checked and under-stood. However, neither Schaffner nor its subsidiaries assume any liability whatsoever for any errors or inaccuracies of this document and the consequences thereof. Published specifications are subject to change without notice. Product suitability for any area of application must ultimately be determined by the customer. In all cases, products must never be operated outside their published specifications. Schaffner does not guarantee the availability of all published products. This disclaimer shall be governed by substantive Swiss law and resulting disputes shall be settled by the courts at the place of business of Schaffner Holding AG. Latest publications and a complete disclaimer can be downloaded from the Schaffner website. All trademarks recognized.