September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical §...

34
Trasfor Low Voltage The future is made of transformations © Trasfor ¦ www.trasfor.com September 20, 2016

Transcript of September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical §...

Page 1: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low VoltageThe future is made of transformations

© Trasfor ¦ www.trasfor.com

September 20, 2016

Page 2: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Transformers are all around us in different segmentsYou will find Trasfor Group transformers…

… in buildings and in the airports weuse when traveling,

… crossing oceans and on the seabed,

… in substations that power ourindustrial areas,

… on the trains we ride and in thefacilities that process our water,

… in wind turbines, solar fields,urban areas and house-holds.

© Trasfor ¦ www.trasfor.com

Page 3: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Group Sites

§ Located in Italy, 10 km from Trasfor SA§ Product portfolio:

LV transformers and reactors, up to 1 MVA

§ Located between Florence and Rome§ Product portfolio:

LV transformers and reactors, up to 200 kVA

Intermagnetics (ITIMG)

Italtrasfo (ITTRF)

§ Located in southern Switzerland,close to Lugano

§ >90% of products exported§ Products: MV & LV transformers and reactors

for specialty and generalmarkets and applications

Trasfor (CHTRF)

© Trasfor ¦ www.trasfor.com

§ Located at 2 driving hours from Sofia§ Serial products§ Product portfolio: LV transformers and reactors§ Feeder factory

BGABB (Sevlievo)

Page 4: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor GroupProduct portfolio

Direct & Indirect water-cooled chokes and transformers

Power ratings: up to 16 MVAVoltages: up to 1.1 kV

Reactors / chokes

Power ratings: up to 25 MVAVoltages: up to 36 kV

Low voltage transformers

Power ratings: up to 15 MVAVoltages: up to 1.1 kV

Cast resin and dry-type transformersfor medium voltage applications

Cast resin transformersPower ratings: up to 25 MVA Voltages: up to 36 kV

Dry-type transformersPower ratings: up to 15 MVA Voltages: up to 24 kV

Products for rolling stock (dry-type)

© Trasfor ¦ www.trasfor.com

Transformers and Reactorsup to 25 kV & 50 kA

Page 5: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low Voltage Applications

© Trasfor ¦ www.trasfor.com

Airport EquipmentWindSolarUPSPower factor correctionData center

Page 6: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Airports Equipment - Technical

§ Powers from 5kVA up to 200kVA

§ AN / AF / AFD vertical or horizontal mounting

§ Input 50/60Hz / Output 400Hz

§ Input isolation transformers for 6 & 12 pulses reaction

§ Input autotransformers for 12 pulses reaction

§ Output transformers impedances from 2 to 35%

§ Input threephase reactors with AFE filtering

§ Output threephase reactors for PWM filtering

§ Overload withstand

§ Humidity and moisture protection

§ Light weight and compact design

§ Guaranteed low noise levels

§ UL insulation system for North American market

© Trasfor ¦ www.trasfor.com

Page 7: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Airports Equipment – Our products

© Trasfor ¦ www.trasfor.com

Page 8: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Airports Equipment - References

§ Hitzinger GmbH Austria

§ Axa Power Denmark

§ Piller GmbH Germany

§ Powervamp United Kingdom

§ Tet-Estel AS Estonia

§ Test Tum Elektronik AS Turkey

§ OCEM Italy (for Lighting solutions)

§ TLD France

© Trasfor ¦ www.trasfor.com

Page 9: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low Voltage ApplicationsWind

© Trasfor ¦ www.trasfor.com

Page 10: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Wind - Technical§ Dry type Transformers and Reactors for ratings up to 16MVA§ AN/AF Cooling§ Direct or indirect water cooling (WF) allows to operate with high current

density – compact and perfectly cooled solution§ Heat is directly removed by cooling liquid – no heating of ambient§ Direct water cooled: water circulates through hollow conductor§ Indirect water cooled: heat exchanger integrated into winding§ Up to rated voltage of 1000 V and insulation voltage of 5 kV§ Typical applications: converters, drives, excitation, wind power

© Trasfor ¦ www.trasfor.com

Page 11: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Wind – Our products

© Trasfor ¦ www.trasfor.com

Page 12: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Wind - References

§ ABB Discrete Motion

§ Acciona

§ Alstom Power

§ Areva

§ Gamesa

§ GE Energy Power Conversion

§ Ingeteam

§ KK Wind Solutions

§ Siemens Wind Power

© Trasfor ¦ www.trasfor.com

Page 13: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low Voltage ApplicationsSolar

© Trasfor ¦ www.trasfor.com

Page 14: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Solar - Technical

§ Transformers ratings from 5kVA up to several MVA§ Single and 3-phase reactors – with iron-core or air-core from 1kVAr up to

several MVAr§ AN / AF§ 50Hz and 60Hz for Transformers – up to 25kHz for reactors§ Al or Cu windings, wire or foil§ Vacuum pressure impregnation (VPI),

thermal class B, F, or H (C Class upon request)§ With any type of enclosure (up to IP66)§ Traditional and transformerless UPS for solar

§ Low losses

§ UL insulation system for North American market

© Trasfor ¦ www.trasfor.com

Page 15: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Solar – Our products

© Trasfor ¦ www.trasfor.com

Page 16: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Solar - References

§ ABB Power Systems

§ ABB Discrete Motion

§ Gamesa

§ Ingeteam

§ Power One

© Trasfor ¦ www.trasfor.com

Page 17: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low Voltage ApplicationsUPS

© Trasfor ¦ www.trasfor.com

Page 18: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:UPS - Technical

© Trasfor ¦ www.trasfor.com

§ Single, 3-phase and 3-to-one phase transformers and autotransformers§ Transformers with integrated inductance for high impedance values§ Up to 1000 V and up to 5 kV§ Power ratings: 5 kVA and larger, up to several MVA§ Single and 3-phase reactors – with iron-core or air-core from 1kVAr up to

several MVAr§ 50Hz and 60Hz for Transformers – up to 25kHz for reactors§ Al or Cu windings, wire or foil§ Vacuum pressure impregnation (VPI), thermal class B, F, or H (C Class upon

request)§ With any type of enclosure (up to IP66)§ For applications like low voltage distribution transformer, rectifier input,

inverter output, isolation, etc.§ Traditional and transformerless UPS, solar and wind energy, drives, inverters,

power factor correction

Page 19: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:UPS – Our products

© Trasfor ¦ www.trasfor.com

Page 20: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

§ AEG Power Solutions

§ ABB Power Protection

§ Emerson Network Power

§ Hitec

§ Hitzinger

§ Legrand

§ Piller

§ Socomec

Applications:UPS - References

© Trasfor ¦ www.trasfor.com

Page 21: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low Voltage ApplicationsPower Factor Correction

© Trasfor ¦ www.trasfor.com

Page 22: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:PFC - Technical

© Trasfor ¦ www.trasfor.com

§ Single and 3-phase reactors – with iron-core or air-core from 1kVAr up toseveral MVAr

§ Up to 1000 V and up to 5 kV§ up to 25kHz for reactors§ Al or Cu windings, wire or foil§ Vacuum pressure impregnation (VPI), thermal class B, F, or H (C Class upon

request)§ With any type of enclosure (up to IP66)

Page 23: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:PFC – Our products

© Trasfor ¦ www.trasfor.com

Page 24: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

§ ABB Jumet

§ ABB China

§ ABB Australia

§ Ducati Energia

§ International Capacitors

Applications:PFC - References

© Trasfor ¦ www.trasfor.com

Page 25: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low Voltage ApplicationsData centers

© Trasfor ¦ www.trasfor.com

Page 26: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Data Centers- Technical

© Trasfor ¦ www.trasfor.com

§ Single, 3-phase and 3-to-one phase transformers and autotransformers§ Transformers with integrated inductance for high impedance values§ Up to 1000 V and up to 5 kV§ Power ratings: 5 kVA and larger, up to several MVA§ Single and 3-phase reactors – with iron-core or air-core from 1kVAr up to

several MVAr§ 50Hz and 60Hz for Transformers – up to 25kHz for reactors§ Al or Cu windings, wire or foil§ Vacuum pressure impregnation (VPI), thermal class B, F, H or C§ With any type of enclosure (up to IP66)

§ Low losses

§ UL insulation system for North American market§ For applications like low voltage distribution transformer,

rectifier input, inverter output, isolation, etc.

Page 27: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Applications:Data Centers – Our products

© Trasfor ¦ www.trasfor.com

Page 28: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

§ ABB PS

§ Emerson Network Power

Applications:Data Centers - References

© Trasfor ¦ www.trasfor.com

Page 29: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor Low VoltageR&D in Trasfor GroupQuality

© Trasfor ¦ www.trasfor.com

Page 30: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

R&D in Trasfor GroupTree of activities

© Trasfor ¦ www.trasfor.com

R&D in Trasfor SA

Structures Acoustics Thermo-fluidDynamics

Static (linear and non-linear)

Lifting

Modal analysis

Shock analysis

Seismic assessment

Fatigue analysis

Bolts verification

Welding verification

Air-borne noise

Structure-borne noise

Cooling systemsoptimisation

Transport

Short circuit

Electromagnetics

Leakage fields(linear and non-linear materials)

Short circuit forces

Mutual inductances

Capacity

Vcc and inductances

No load losses

Electrical circuit(SPICE input)

Wind gust resistance

Stray losses

Page 31: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

R&D in Trasfor GroupMechanical

§ Valued added solution§ 3D drawings on customers requests§ Possibility to work directly on 3D frame of

customer cabinets.§ .Step and PDF 3D files of our components

available for our clients

© Trasfor ¦ www.trasfor.com

Page 32: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor, Italtrasfo & Intermagnetics:Quality through ISO certification 9001:2008Quality through total respect of environment with ISO 14001-2004Quality through total respect of HSE OHSAS 18001:2007

Quality for the railway industry as IRIS – International Railways IndustryStandard

Quality of products and people through ISO EN 3834-2, EN 15085, UL FileE172880 and UL File E216928 certification

Certificate of conformity to GOST-R

Quality through entrustment by the following certifying bodies:

ABS - American bureau of shippingDNV - Det norske veritasGL - Germanischer Lloyd

Trasfor GroupQuality

© Trasfor ¦ www.trasfor.com

Page 33: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

Trasfor is your partner...§ 50 years experience for many different applications and needs – customized solutions§ Large experienced engineering team (more than 40 people strong), we can work with

your engineers in order to define the most effective solutions§ Excellent know-how for wind, solar inverters, UPS, power quality and VSD drives

applications§ Specialized know-how from dry-type magnetic components for rolling stock

applications, one of the toughest environment. VPI production process.§ Flexibility to follow your needs, with small volumes, prototypes and mass production.§ Quick response to your demands: 3 production sites available§ Supplier to many high reputation companies thanks to the quality of our products§ for large series or single units – transformers and reactors, small and big, LV or MV§ with AN, AF, or WF cooling – standard and customized enclosures§ experienced for many different applications and needs – customized solutions§ great flexibility in production both for the type of magnetic objects and the quantities

needed§ wide range of certifications§ able to supply assembled kits

© Trasfor ¦ www.trasfor.com

Page 34: September 20, 2016 Trasfor Low Voltage The future is made ... · Applications: Wind - Technical § Dry type Transformers and Reactors for ratings up to 16MVA § AN/AF Cooling § Direct

© Trasfor ¦ www.trasfor.com