Separating substances with the same relative atomic mass · Separating substances with the same...
Transcript of Separating substances with the same relative atomic mass · Separating substances with the same...
![Page 1: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/1.jpg)
High Resolution Quadrupole Analysis
Separating substances with the same relative atomic mass
![Page 2: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/2.jpg)
Separating two molecules with a
quadrupole
o High Stability Power Supplies
o Large Diameter Quadrupole Rods
o Fine Control Over Scanning Variables
Only the VeraSpec HRQ, powered by the MAX-
50, has these capabilities
![Page 3: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/3.jpg)
Stability over Time
• VeraSpec HRQ’s unparalleled stability
– 10 hours at high resolution
– Monitoring He and D2
![Page 4: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/4.jpg)
High Resolution
• Measuring system resolution at Argon at m/z 40
– M/∆M ≥ 4000
![Page 5: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/5.jpg)
Masses 1 – 4 in High Res Mode
• Hydrogen, Helium, HD, and Deuterium separated at their primary masses
– Helium and Deuterium shown separated at mass 4
![Page 6: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/6.jpg)
Helium and D2
• Helium and Deuterium are 0.026 amu apart and can be easily
separated to baseline by the HRQ
![Page 7: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/7.jpg)
Carbon Monoxide and Nitrogen
• The power of the MAX-50 is able to separate even difficult molecules such as CO and N2
– These are only 0.011 amu apart!
– Not to baseline but enough for qualitiative analysis
![Page 8: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/8.jpg)
VeraSpec HRQ
• Designed for precision mass
analysis of low molecular
weight species
– Delivers exceptional transmission
characteristics
– Built on the foundation of the
MAX 50 flange mounted
quadrupole mass spectrometer
• The HRQ has a 50 amu mass
range and resolution of better
than 3,000 (m/Δm) at m/z 40
![Page 9: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/9.jpg)
Product Information
• Specifications
– Designed for precision mass
analysis of low molecular weight
species
• Built on the foundation of the
MAX 50 flange mounted
quadrupole mass spectrometer
– Delivers exceptional transmission
characteristics
– Resolution of better than 3,000
(m/Δm) FWHM at m/z 40
• You can separate compounds
0.02 amu apart to baseline
• Options
– Inlet Customization
• Model shown includes fully
automated gate valve and gas
handling
– Mass Range
• 1-50 amu
• 1-120 amu
![Page 10: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/10.jpg)
Review of Strengths of HRQ
![Page 11: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/11.jpg)
Review
• Why buy Extrel?
o Ability to separate Helium and Deuterium to baseline, a separation of 0.026 amu
o Extrel instrument is a better buy at a lower for a higher sensitivity and higher resolution
system
![Page 12: Separating substances with the same relative atomic mass · Separating substances with the same relative atomic mass. Separating two molecules with a quadrupole o High Stability Power](https://reader035.fdocuments.in/reader035/viewer/2022071219/6057b8acbe0b064dcb747047/html5/thumbnails/12.jpg)
For More Information:Contact the local Extrel distributor(for Germany, Austria, Benelux) :
Hositrad Vacuum Technology , Phone +31 33 253 7210
Email: [email protected]