Sensus Product Brochure v7 (May 2015)

28
8/19/2019 Sensus Product Brochure v7 (May 2015) http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 1/28 Thames Water Product  Guide  Version 7.0 

Transcript of Sensus Product Brochure v7 (May 2015)

Page 1: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 1/28

Thames Water 

Product 

Guide Version 7.0 

Page 2: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 2/28

www.sensus.com

© 2015 Sensus. All rights reserved.

Contents

640e Smart Meter  

iPerl Smart Meter  

MeiStream Plus Smart Meter 

MeiStream Plus (mechanical register)

MeiStream Plus-e (electronic register)

550 LCE Smart Point

SIRT

Correct as of Feb 2015

Contents to be updated periodica

Page 3: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 3/28

Volumetric Meter - Composite

Body with Electronic Register

Applications

The 640C/640MC is a high precision meter.

Due to its unique piston and measuring chamber design, the smallest drops

of water are measured.

With the 640C/640MC you are assured of proven metrology of an established

meter with advantage of built in communications capability.

The 640C meter range includes an electronic register with integrated radio

functionality which enables easy and fast communication.

Due to our broad range of system solutions you can adapt the 640C/640MC toall your AMR, AMI requirements.

The protection class of the electronic register of the 640C family is IP 68 rated.

With a tamper proof design and its long life span you can be confident when

selecting the 640C/640MC.

Main characteristics

DN 15 to 20 and Coax, MAP 16, T50 (temperature

range 0,1 to 50 °C)

Light and robust

Easy to handle

Meets current and anticipated regulations forpotable water

Environmentally friendly

Unrivalled accuracy and measuring range

High resistance to impurities and aggressive water

Quiet operation

Ready for wireless communication with integrated

radio functionality (available in differentfrequencies)

Long lasting battery life expectation inclusive of

metrology and radio function

The register includes a lithium battery

www.sensus.com

640C

640MC

Page 4: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 4/28LD1670INT  Page 2

Typical Marking

Markings may vary depending on particular

markets or metrological specifications.

Accuracy and Reliability

Thanks to the advanced design of its measuring

chamber the meter has a low starting flow.

It can be supplied with metrological seal according

the MID regulation 2004/22/EC with a ratio up to

R400.

Foreign matter present in the water is filtered out

by either the tubular strainer on the inlet or the seat

strainer. All electronic components of the register

are hermetically sealed and assembled in a glasscopper casing which allow the protection class IP68.

The 640C/640MC water meter retains its

metrological accuracy for many years of operation,

even in difficult working conditions.

Typical Accuracy Curve

Typical Head Loss Curve

Cross Section

   A  c  c  u

  r  a  c  y   (   %   )

FlowQ1 Q2 Q3 Q4

  D  N   2  5

Flow rate (l/h)

10000

   H  e  a   d   l  o  s  s   (   b  a  r   )

0

1

640C DN15640MC

1

  D  N   1  5

  D  N   2  0

5

0

-5

2

-2

Page 5: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 5/28

640C / 640MC

LD1670INT  Page 3

Approvals

EC type-examination certificate

in conformity with

  • 2004/22/EC (MID)

  • EN 14154:2007

  • OIML R49:2006

  • ISO 4064:2005

Q3 2,5 DE-07-MI001-PTB002

Q3 4 DE-09-MI001-PTB004

Certificate of compliance for potable drinking water

KTW/DVGW (D) ACS (F)

WRAS (UK) Hydrocheck (B)

KIWA ATA (NL)

Legibility

The display with 9 digits (6 for m3, 3 for litres)

ensures exceptional readability. The highestresolution in testing mode is 0.05 litres.

Icons are also displayed on the LCD to indicate

important information have been registered:

Performance Data

Dimensions and Weights

Metrological characteristics

Directive 2004/22/EC (MID) & EN 14154:2007

(1) Values for R=400

(1) Also available in length 110/114/115/130/134 and 165 mm(2) Also available in length 165 and 190 mm with 1" threads(3) Also available in length 165 and 220 mm

640MC 640C

CoaxialManifold

Inline

Nominal Size DN mm # 15 20

Length L mm   170(1)

190(3)

Width D mm   101.7 101.7 113.5

Total height H mm 140.3 142.6 149

Height to pipe axis h mm 18.95 21.5

Tail Diameter inch G 1½" B G ¾" B(2)

G 1" B

Piece mm   47.8 26.44 33.25Thread Pitch 2.31 1.81 2.31

Weight kg 0.5 0.6 0.68

Dimensional Diagram

For the installation guidelines please refer to our website and the manual MD 1670 INT.

Coaxial

ManifoldInline

Nominal Size DN mm # 15 20

Permanent flowrate Q3 m³/h 2.5 2.5 4

Ratio “R” Q3 /Q1 R 40 / 80 / 160 / 315 / 400

Maximum flowrate(1)

Q4 m³/h 3.125 3.125 5.0

Minimum flowrate(1)

(tolerance ±5%)Q1 l/h 6.25 6.25 10.0

Transitional flowrate(1)

(tolerance ±2%)Q2 l/h 10.0 10.0 16.0

D

L

H

   h

Alarm is triggered

Low battery level is reached

Radio is activated

System is set up in hydraulic testing mode

indicates positive or negative flow

indicates the unit programmed in use

H

D

Page 6: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 6/28

UK & Ireland Enquiries

Sensus UK Systems Ltd, International House, Southampton International Business Park,George Curl Way, Southampton SO18 2RZ UK

T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com

International EnquiriesSensus GmbH Ludwigshafen, Industriestrasse 16, 67063 Ludwigshafen Germany

T: +49 (0) 621-6904-0 F: +49 (0) 621-6904-1409 Email: [email protected] www.sensus.com

14001 Subject to changes without prior notice.LD1670INT  Page 4

The 640C product range has SensusRF integrated

technology providing the advantages of both uni-

and bidirectional system architecture as described

below. SensusRF is the optimized radio system forbattery driven endpoints. Scalable for mobile and

remote reading without exchange of components, it

is available in 433 MHz.

Sensus offers two communication modes:

1. FlexNet™ Radio Network AMI

 • 2 Way Long Range Radio AMI System

 • Utility Grade Licensed Spectrum

 • Direct to tower, minimal network infrastructure

 • Excellent first time connection rates

 • Easy integration of additional applications

(SCADA, acoustic loggers)

 • Secure and resilient

 • Meter reading transparent

 • Fast track alarms

 • DMA snap shot (snap shot of a water network

for evaluation)

 • High level of data security (end-to-end

encryption)

SmartPoint

The SmartPoint (SP) radios are capable of 2 way

communications. The SP captures data wirelessly

from the 640C and transmits to the RNI via theTGB. The SP can receive data from the RNI such

as firmware upgrades and alarm configuration

changes.

2. Mobile Read - Walk-by / Drive-by AMR

 • Unidirectional telegrams

 • Bidirectional communication

 • Spontaneous reception possible without route

 • Configuration of the endpoint

SIRT (Sensus Interface Radio Tool)

SIRT is a radio modem for SensusRF radio,connected to a handheld via Bluetooth and using

SensusREAD Mobile Reading software with the

following features:

 • Installation and readout of devices

 • Reception of frequently transmitted radio

messages from Sensus RF radio endpoints

 • Request additional information from the radioendpoints

 • Change configuration of radio endpoints

(alarm level settings... )

640C/640MC infrastructure

Certified according to ISO 9001

Quality Management System Quality Austria Reg.no. 3496/0

433 MHz Drive-by

1000 m distance with 50 km/h speed

telegram with meter ID, index and alarm

Mobile Read - Walk by/ Drive by

 5  0  0 m

640C/640MC FlexNet™ radio network - Remote Access & Monitoring

SP

SP

SP

SP AMI SmartPoint

TGB Tower Gateway BaseRNI Regional Network Interface

TGB

RNI

SIRT

SIRT linkedvia Bluetooth

with handheld

device

Page 7: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 7/28

The evolution of technology associated with managing water networks and measuring consumption

is entering a new era. The era of iPERL.

Throughout history, the way that societies collect, distribute and gain access to potable

water has inspired a culture of invention and innovation…and this continues today with

iPERL, a breakthrough technology that defines a smarter future.

Simplicity, Productivity and Environmental Sustainability are the three axis of innovation

embodied in iPERL. No measurement technology has ever offered such intelligent end-

point data functionality. No measurement technology has ever provided the ability to createso much value through water network management and consumption accuracy.

iPERL - the new data end-point standard fully enabled for a new era.

DELIVERING ESSENTIAL VALUE THROUGH TECHNOLOGY INNOVATION

SIMPLE

iPERL is founded on

complete and simple

life-cycle principles.

From the selection of thenetwork fitting sizes for

the end-point, through

to delivery and usage

experience and on to

disposal, the technology

has been designed withsimplicity, productivity and

sustainability in mind.

ACCURATE

iPERL accuracy offers

real value throughout

its wide measuring range

independent of waterquality, network pressure or

piping section modifications.

No other current technology

can match iPERL.

LONG LASTING

iPERL delivers its core

values throughout its

complete life-cycle. Its

innovative measuringtechnology assures iPERL’s

enduring accuracy in

the field, delivering a

continuous data stream.

Page 8: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 8/28

RELIABILITY

Extreme testing conditions, an innovative

mechanical design, extensive Sensus

experience and the blending of state-of-

the-art technologies ensure that iPERL

complies with T50 requirements, creating

a unique, robust and long-lasting water

data end-point.

Controlled Accuracy

As installation points are not always ideal,

iPERL has been designed for installation

in any orientation, independent of

flow direction and with no effect on

metrological performance.

LOW RISK

Investing in iPERL is investing in thefuture. Its inbuilt performance brings

considerable economic value with fast

ROIs and the flexibility to optimize future

opportunities.

iPERL’s inbuilt data logging allows utilities

to pro-actively monitor and adapt to

changing consumption habits, triggering

potential, additional consumer services.

Approvals

EC type-examination certificate

In conformity with

  •  2004/22/EC (MID)

  •  EN 14154:2007

  •  OIML R49:2006

Certificate of Compliance For Potable

Drinking Water

In conformity with

  •  KTW / DVGW (D)

  •  ACS (F)

  •  WRAS (UK)

A PRODUCTIVITY engine

for the water NETWORK 

TYPICAL ACCURACY CURVE

PRESSURE LOSS CURVE

PERFORMANCE DATA

PRODUCTIVITY

iPERL comes with an inbuilt R800 ratio for all models in the proposed family

range, from Q3 2.5 to 16 m3 /h. Such a value proposition means there is no

trade-off between performance and network conditions.

Due to its technology, iPERL’s R800 ratio meets utilities’ expectations

throughout iPERL’s life-time.

1.0

0.01

0.10

1.00

10.0

    P   r   e   s   s   u

   r   e     L

   o   s   s    [    b   a   r

    ]

Nominal Diameter DN mm 15 20 25 30 40

Permanent flowrates Q3

m3 /h 2.5 4 6.3 10 16

Ratio “R” Q3 /Q

1R 800

Maximum Flowrate Q4

m3 /h 3.125 5 7.875 12.5 20

Minimum Flowrate Q1

l/h 3.13 5 7.88 12.5 20

Transitional Flowrate Q2

l/h 5 8 12.6 20 32

   P  r  e  s  s

  u  r  e

   l  o  s  s

   [   b  a  r   ]

  D  N  2 0

  D  N  1  5

Page 9: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 9/28

ENVIRONMENTAL

iPERL is focused on achieving the lowest

possible environmental impact. Such

impact is measured through a complete

life-cycle analysis covering climate

change, ecosystem quality, human health

and natural resources.

iPERL was developed with disposal in

mind and is manufactured using fullyrecyclable materials.

iPERL is designed to meet the demands

of even the most severe field utilisations.

These include the fast open and close

tap movements that create fast flow

transients difficult to capture and

account for…and typical in residential and

commercial applications.

iPERL is fully protected against all water

network hazards. It is built to accommodateinterior and exterior installations. It is IP68

rated and fully protected against water

vapour transmissions that would occur

with the presence of any air.

Communications

iPERL is equipped with Sensus low

power 868MHz or 433MHz integrated

radio technology. Utilising a 1½ way

communication system, it offers both

the benefits of one and two way system

architecture. The innovative designprovides billing and alarm status for walk-

by / drive-by collection, plus in addition

the ability to interrogate the meter for

more detailed data including data logging

of up to 2880 values.

Along with Sensus Radio, iPERL also offers

an OMS certified T1 broadcast platform.

Long Range Radio

Sensus Radio will provide a link to the

long range radio infrastructure, FlexNet,allowing iPERL to be directly integrated.

With the utility grade communications

technology and whole life values of

iPERL, we offer a technology roadmap

fully aligned to a smarter future.

Dimensional Diagram

Dimensions

L H h B1 B2

DN15

110

120 26.5

92.5115

134

145

165104

170

DN20

10592.5

115

153

104165

190

LAY LENGTH

DN Available Lay Length (mm)Thread

acc.ISO

15 110 115* 134 145 165 170 3/4”

20 105 115 153 165 190 - 1”

25 198 260 - - - - 1 1/4”

30 260 - - - - - 1 1/2”

40 300 - - - - - 2”

* Also available with thread acc. ISO 3/4” x 7/8”

DN 15 / DN 20 DN 15 / DN 20

Page 10: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 10/28

www.sensus.comLD 5000 INT 0001

I  n c l   u d  e s  s  en s  or  t  e c h n ol   o g y

l  i   c  en s  e d  b  y S  en t  e c L i  mi   t  e d 

Page 11: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 11/28

www.sensus.com

Applications

 • Measurement for billing of cold potable water up to 50 °C

 • Measurement of medium and high flowrates

 • Measurement of low flow e. g. in light load periods

 • For leakage control

Available options

 • HRI-Mei factory mounted

 • Version for use in hazardous area

 • ¼" pressure monitoring port

 • Encoder register with different data protocols

Main characteristics

 • Meter with MID pattern approval acc. to annex

MI001

 • Exchangeable metrological unit with MID patternapproval acc. to annex MI001

 • Unique measuring range; Q3 /Q1 ≥ 315 in

horizontal installation

 • High overload capability

 • No straight inlet length necessary (U0D0 acc. to

OIML R49 and EN 14154)

 • Meter body in short (WP) and long (WS) overalllength acc. to DIN 19625 and EN 14154 available

 • Meter can be submerged; protection class IP68

 • Used materials are temperature resistant upto 70 °C

 • Register prepared for HRI-Mei pick-up

 • Use of optical pulsers type OD is still possible

MeiStream

Plus

Class C Bulkmeter for coldpotable water DN 40...150 PN 16

Page 12: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 12/28LB1060INT  Page 2

Dial

Meter cpl. and exchangeablemetrological unit

Marking CE M-XX* 0102

DE-09-MI001-PTB 012

* year of production

Nominaldiameter

DN

Smallest reading

m3

Max. reading

m3

40 ... 100 0.0005 999,999.999

150 0.005 9,999,999.99

DN 40...100 DN 150

Performance Data

Size DN 40 50 65 80 100 150

Q5 Max. Peak Flow m³/h 50 55 60 120 160 400

Q3' Continuous Flow m³/h 30 35 40 63 100 250

Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63

Q1' Minimum Flow horizontal m³/h 0.08 0.07 0.1 0.13 0.2 0.35

Starting Flow m³/h 0.03 0.03 0.035 0.04 0.065 0.12

Size DN 40 50 65 80 100 150

Q4 Overload Flowrate acc. to MID m³/h 31.25 31.25 50 78.75 125 312.5

Q3 Permanent Flowrate acc. to MID m³/h 25 25 40 63 100 250

Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63

Q1 Minimum Flowrate horizontal acc. to MID m³/h 0.08 0.08 0.1 0.16 0.25 0.4

Q3/ 

Q1

max. Ratio 315 315 400 400 400 630

Q3/ Q1 Standard Marking 315 315 315 315 315 315

∆p Headloss at Q3 acc. to EN 14154 bar 0.09 0.08 0.17 0.07 0.16 0.14

Metrological Data acc. to Manufacturers Values

Metrological Data acc. to 2004/22/EC (MID)

Approval Mark

Page 13: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 13/28

MeiStream Plus

LB1060INT  Page 3

Typical Headloss

Materials

Typical Error Curve

Installation Requirements

Available Lengths

Pulse Values

Pulser Type Pulse Value

HRI-Mei (Leaflet see LS 8400) 0.01; 0.05; 0.1 or 1 m3 0.1; 0.5; 1 or 10 m3

OD 01 (Leaflet see LB 8300) 0.001 m3 0.01 m3

OD 03 (Leaflet see LB 8300) 0.01 m3 0.1 m3

DN 40 ... 100 DN 150

Pipe horizontal

Meter head upwards

  • Unrestricted straight pipe upstream 0 x DN

  • No abrupt restrictions directly downstream of the meter

Body Cast iron

Measuring element Plastic

Rotor Plastic

We also use the followingmaterials

 Brass Stainless steel

Nominal diameter 40 50 65 80 100 150

Overall length L

WS (DIN / ISO)mm

270 /

300300

300 /

350

360 /

350500

Overall length LWP (DIN / ISO)

mm 220 200 200225 /

200250 300

Flowrate m3/h

   H  e  a   d   l  o  s  s

Q1   Q3Q2   Q4

5%

2%

2%

5%

m3/h

+

-

Flowrate m3/h

   E  r

  r  o  r   %

m³/h

Installation

Page 14: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 14/28

Certified according to ISO 9001

Quality Management System Quality Austria Reg.no. 3496/0

UK & Ireland Enquiries

Sensus UK Systems Ltd, International House, Southampton International Business Park, George Curl Way,Southampton SO18 2RZ UK

T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com

International EnquiriesSensus GmbH Hannover, Meineckestraße 10, D-30880 Laatzen Germany

T: +49 (0) 5102 74-0 F: +49 (0) 5102 74-3341 Email: [email protected] www.sensus.com

12006 Subject to changes without prior notice.LB1060INT  Page 4

Dimension and Weights PN 16

Order Information

Nominal diameter 40 50 50 50 65 65 80 80

Dimensions Overall length L mm 220 200 270 300 200 300 200 225

  Height H mm 120 120 120 120 120 120 150 150

  h mm 69 73 73 73 85 85 95 95

  Dismantling height g mm 200 200 200 200 200 200 270 270

Weights Meter cpl. kg 7.5 7.8 9.6 9.9 10.1 12.0 13.8 14.2

  Measuring insert kg 1.5 1.5 1.5 1.5 1.5 1.5 3.2 3.2

  Body kg 6.0 6.3 8.1 8.4 8.6 10.5 10.6 11.0

Nominal diameter 80 80 100 100 100 150 150

Dimensions Overall length L mm 300 350 250 350 360 300 500

  Height H mm 150 150 150 150 150 177 177

  h mm 95 95 105 105 105 135 135

  Dismantling height g mm 270 270 270 270 270 356 356

Weights Meter cpl. kg 16.3 17.7 18.2 20.0 20.2 35.9 44.2

  Measuring insert kg 3.2 3.2 3.2 3.2 3.2 5.9 5.9

  Body kg 13.1 14.5 15.0 16.8 17.0 30.0 38.3

MeiStream Plus, DN 50, T50, PN16

Drilling EN 1092 PN16

Length 270 mm

mechanical register / m³

with MID conformity

Type

Size

Max. medium temperature

Nominal pressure

Drilling pattern

Body length

Register type / unit

Approval standard

Dimension Picture

Page 15: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 15/28

Class C Bulkmeter with

eRegister for cold potable

water DN 40...150 PN 16

Applications

 • Measurement for billing of cold potable water up to 50 °C

 • Measurement of medium and high flowrates

 • Measurement of low flow e. g. in light load period

 • For leakage control

 • Integration into Smart Water Networks

Main characteristics

 • Meter with MID pattern approval acc. to annexMI001

 • Exchangeable metrological unit with MID

pattern approval acc. to annex MI001

 • Unique measuring range; Q3/Q1 315 inhorizontal installation

 • High overload capability

 • No straight inlet length necessary (U0D0 acc.to OIML R49 and EN 14154)

 • Meter body in short (WP) and long (WS)

overall length acc. to DIN 19625 and EN 14154available

 • Meter can be submerged; protection class IP68

 • Used materials are temperature resistant up

to 70 °C

 • Register with integrated radio communication

 • LC-display

www.sensus.com

MeiStream

Plus

Available options

 •Radio communication with different frequencies

 • ¼" pressure monitoring port

Page 16: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 16/28LB1080INT  Page 2

Dial

Meter cpl. and exchangeable metrological unit

Marking CE M-XX* 0102

 

DE-09-MI001-PTB 012

* year of production

Performance Data

Size DN 40 50 65 80 100 150

Q5 Max. Peak Flow m³/h 50 55 60 120 160 400

Q3' Continuous Flow m³/h 30 35 40 63 100 250

Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63

Q1' Minimum Flow horizontal m³/h 0.08 0.07 0.1 0.13 0.2 0.35

Starting Flow m³/h 0.03 0.03 0.035 0.04 0.065 0.12

Size DN 40 50 65 80 100 150

Q4 Overload Flowrate acc. to MID m³/h 31.25 31.25 50 78.75 125 312.5

Q3 Permanent Flowrate acc. to MID m³/h 25 25 40 63 100 250

Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63

Q1 Minimum Flowrate horizontal acc. to MID m³/h 0.08 0.08 0.1 0.16 0.25 0.4

Q3/ Q1 max. Ratio 315 315 400 400 400 630

Q3/ Q1 Standard Marking 315 315 315 315 315 315

∆p Headloss at Q3 acc. to EN 14154 bar 0.09 0.08 0.17 0.07 0.16 0.14

Metrological Data acc. to Manufacturers Values

Metrological Data acc. to 2004/22/EC (MID)

Alarm is triggered

Low battery level is reached

Radio is activated

System is set up in hydraulic testing mode

indicates positive or negative flow

indicates the unit programmed in use

Nominal

diameter

DN

Smallest readingm3

Max. readingm3

40 ... 100 0.001 999,999.999

150 0.01 9,999,999.99

Approval Mark

Page 17: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 17/28

MeiStream Plus

LB1080INT  Page 3

Typical Headloss Typical Error Curve

Installation RequirementsInstallation

 • Unrestricted straight pipe upstream 0 x DN

 • No abrupt restrictions directly downstream of the meterPipe horizontal

Meter head upwards

Materials

Body Cast iron

Measuring element Plastic

Rotor Plastic

We also use the following

materials

Brass

 Stainless steel

Battery Lithium

Available Lengths

Nominal diameter 40 50 65 80 100 150

Overall length LWS (DIN / ISO)

mm270 /300

300300 /350

360 /350

500

Overall length LWP (DIN / ISO)

mm 220 200 200225 /

200250 300

Flowrate m3/h

   H  e  a   d   l  o  s  s

Q1   Q3Q2   Q4

5%

2%

2%

5%

m3/h

+

-

Flowrate m3/h

   E  r  r  o  r

   %

Page 18: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 18/28LB1080INT  Page 4

Dimension and Weights PN 16

Order Information

Nominal diameter 40 50 50 50 65 65 80 80

Dimensions Overall length L mm 220 200 270 300 200 300 200 225

  Height H mm 120 120 120 120 120 120 150 150

  h mm 69 73 73 73 85 85 95 95

  Dismantling height g mm 200 200 200 200 200 200 270 270

Weights Meter cpl. kg 7.5 7.8 9.6 9.9 10.1 12.0 13.8 14.2

  Measuring insert kg 1.5 1.5 1.5 1.5 1.5 1.5 3.2 3.2

  Body kg 6.0 6.3 8.1 8.4 8.6 10.5 10.6 11.0

Nominal diameter 80 80 100 100 100 150 150

Dimensions Overall length L mm 300 350 250 350 360 300 500

  Height H mm 150 150 150 150 150 177 177

  h mm 95 95 105 105 105 135 135

  Dismantling height g mm 270 270 270 270 270 356 356

Weights Meter cpl. kg 16.3 17.7 18.2 20.0 20.2 35.9 44.2

  Measuring insert kg 3.2 3.2 3.2 3.2 3.2 5.9 5.9

  Body kg 13.1 14.5 15.0 16.8 17.0 30.0 38.3

MeiStream Plus, DN 50, T50, PN16

Drilling EN 1092 PN16

Length 270 mm

eRegister / m³

with MID conformity

Type

Size

Max. medium temperature

Nominal pressure

Drilling pattern

Body length

Register type / unit

Approval standard

Dimension Picture

Page 19: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 19/28

UK & Ireland Enquiries

Sensus UK Systems Ltd, International House, Southampton International Business Park,George Curl Way, Southampton SO18 2RZ UK

T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com

International EnquiriesSensus GmbH Ludwigshafen, Industriestrasse 16, 67063 Ludwigshafen Germany

T: +49 (0) 621-6904-0 F: +49 (0) 621-6904-1409 Email: [email protected] www.sensus.com

14001 Subject to changes without prior notice.LB1080INT  Page 5

The MeiStream Plus product range has SensusRF

integrated technology providing the advantages of

both uni- and bidirectional system architecture as

described below. SensusRF is the optimized radiosystem for battery driven endpoints. Scalable for

mobile and remote reading without exchange of

components, it is available in 433 MHz.

Sensus offers two communication modes:

1. FlexNet™ Radio Network AMI

 • 2 Way Long Range Radio AMI System

 • Utility Grade Licensed Spectrum

 • Direct to tower, minimal network infrastructure

 • Excellent first time connection rates

 • Easy integration of additional applications

(SCADA, acoustic loggers)

 • Secure and resilient

 • Meter reading transparent

 • Fast track alarms

 • DMA snap shot (snap shot of a water network

for evaluation)

 • High level of data security (end-to-end

encryption)

SmartPoint

The SmartPoint (SP) radios are capable of 2 way

communications. The SP captures data wirelessly

from the MeiStream Plus and transmits to the RNIvia the TGB. The SP can receive data from the RNI

such as firmware upgrades and alarm configuration

changes.

2. Mobile Read - Walk-by / Drive-by AMR

 • Unidirectional telegrams

 • Bidirectional communication

 • Spontaneous reception possible without route

 • Configuration of the endpoint

SIRT (Sensus Interface Radio Tool)

SIRT is a radio modem for SensusRF radio,connected to a handheld via Bluetooth and using

SensusREAD Mobile Reading software with the

following features:

 • Installation and readout of devices

 • Reception of frequently transmitted radio

messages from Sensus RF radio endpoints

 • Request additional information from the radioendpoints

 • Change configuration of radio endpoints

(alarm level settings... )

MeiStream Plus infrastructure

Certified according to ISO 9001

Quality Management System Quality Austria Reg.no. 3496/0

1000 m distance with 50 km/h speed

telegram with meter ID, index and alarm

Mobile Read - Walk by/ Drive by

 5  0  0 m

MeiStream Plus FlexNet™ radio network - Remote Access & Monitoring

SP

SP AMI SmartPoint

TGB Tower Gateway BaseRNI Regional Network Interface

TGB

RNI

SIRT

SIRT linkedvia Bluetooth

with handheld

device

433 MHz Drive-by

SP

SP

Page 20: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 20/28

DS-C-550M-WSMPT

FlexNet 550M Water SmartPoint

The FlexNetTM 550M Water SmartPoint

provides the capability of a stepped AMR to

 AMI solution for Utilities. It is a device that

allows the Utility to deploy Water meters in

either mobile mode with Walk-by / Drive-by

reads, or in Long Range Radio mode using

Sensus FlexNetTM technology. This allowsthe Utility to deploy Water meters and utilize

the system from day one of deployment

if their requirement does not warrent

initial deployment of a Long Range Radio

infrastructure. Once the radio infrastructure

is installed, the SmartPoint can be remotely

switched from Walk By / Drive By to FlexNet

Long Range Radio without dispatching

engineers to site.

The FlexNetTM 550M Water SmartPoint

supports OFCOM-licensed frequencies in the410-430 MHz radio spectrum.

The SmartPoint offers several advantages

that control both deployment and operation

costs. It’s powerful radio transmitter can

broadcast over large distances and minimizes

collection infrastructure. Once the Smartpoint

is installed, its migratable, two-way system

platform can be updated without requiring

personnel to visit each meter and/or

inconveniencing customers.

Flexible Meter Reading

 Applications•  Advanced Meter Infrastructure (AMI) for water 

• Supports over the air AMR to AMI transistion

Features

• Walk By / Drive by (SensusRF) support

• Long Range Radio (Sensus FlexNetTM)

• 15 Year lifespan

• Supports AES 256bit Encryption

• Easily mounted in any meter pit

• Firmware upgradable

• Battery powered

Page 21: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 21/28

FlexNet 550M Water SmartPoint

Specications

8601 Six Forks Road, Suite 700

Raleigh, NC 27615

1-800-638-3748

For more information, visit us at sensus.com

© 2012 Sensus. FlexNet and SmartPoint are trademarks of Sensus. The Sensus logo is a registered trademark of Sensus.

This product is licensed by IntusIQ under one or more of the following patents: 6,249,516; 6,437,692; 6,914,893; 7,054,271; 7,103,511; 7,468,661; 7,697,492 and 6,891,838.  

Operating Temperature +40 0C to -25 0C

Lifespan   15 Years

Battery C-cell or D-cell*

Security   AES256 Encryption

Memory Firmware Upgradable

Physical

Characteristics

Width: 140.5mm x Height

62.71mm x Depth 63.38mm

WeightC-cell version 185 grams

D-cell version 235 grams*

Transmitter Power 1 Watt +30dBm nominal

+1/-2dBm, at 25C

FlexNet radio network - Remote Access and Monitoring

*D-cell version End of 2014 

ServicePit set installation interfacing to the utility

meter via low power radio

Installation

Environment100% Condensing, Water submersable

Frequency Range   412-412 MHz / 422-424 MHz

Sensus RF

Modulation

Propriatary Narrow Band

2 FSK (100 kbps)

Sensus FlexNet

Modulation

7 FSK Half Baud, C&I (4.022 kbps)

13 FSK Half Baud, Priority (8.044 kbps)

7 FSK (8.044 kbps)

13 FSK (16.088 kbps)

2 FSK (5 kbps)

Mounting

Brackets

Mounting accessories are available to

ensure a secure and reliable tting can

be achieved for a variety of boundary

boxes and installation locations.

140mm

62.71mm

63.38mm(including weld ash)

20e/620Me FlexNet™ radio network - Remote Access & Monitoring

SP

SP

SP

SP AMI SmartPoint TGB Tower Gateway Base

RNI Regional Network Interface

 TGB

RNI

Page 22: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 22/28

Sensus Interface Radio Tool (SIRT433)Manual

MS 2511 INT SIRT, page [email protected]

On (yellow) On/Off indicationblinking : battery < 2,9V 

RF and BT is switched offCharge (red) On: Battery charging

Blinking: charge < 10%Blinking for 5 sec: charge <50%

Bluetooth (blue) Bluetooth connection on/offBlinking: BT communication

Warnings SIRTwill be switchedoff next

Y+R+B blinking: Contact SensusY+R blinking: battery < 2,7V or

T<-20°C or T>60°C 

USB Mini Plug Communication via USB virtualCOM portCharging the battery

On/Off switch Switching device on/off

 Antenna plug For the connection of theexternal Sensus antenna(order no.04410537)

The backside clip can be used tocarry the SIRT on a belt. Toavoid rain entering theelectronics use the lids forexternal antenna plug and USBplug. The plugs must be on thebottom side. When wearing SIRTon your belt, be careful of theinternal antenna reception.Position and angle of the meterreader to the radio endpoint

influence the radio range.

SIRT uses a Lithium Ion battery which must behandled and charged according to this manual andwith the attached Sensus power supply device only.Opening the housing or using other accessories isforbidden and stops all warranty claims againstSensus. SIRT may only be used in environmentconditions set out at the end of this manual.

Parts of delivery (order no.: 04410538)1) SIRT radio modem with internal antennas for

Sensus-RF

2) USB cable with Mini B- and Type A-plug

3) 240/110V/50/60Hz mains power supply

4) This manual

 Accessories:

1) External antenna order no.: 04410537

2) Battery change on request

3) Single 240/110V/50/60Hz mains power supply

Incl. USB cable order no.: 04410532

4) 12V car cigarette lighter power supply incl.

USB cable order no.: 04410533

5) Single USB cable order no.: 04410536

Short description:

SIRT is a radio modem for Sensus Radio connection

to the PSION handheld via Bluetooth and using

SensusREAD software with the following features:

• Receiving of frequently transmitted radio

messages from Sensus RF radio endpoints.

• Requesting more information from the radio

endpoints

• Chang ing configuration of radio endpoints

Note: SIRT supports Sensus-RF, but does notsupport Sensus((S))cout radio.

In addition, the SIRT can be connected to a desktopor laptop computer using USB or Bluetooth. Followsystem requirements acc. to SensusREADapplication software.SIRT provides 2 internal antennas and forwardsradio messages from the strongest one received(diversity function)

Pairing via Bluetooth:The pairing procedure must be done at the first useof SIRT with the computer or handheld.

Pairing with PSION Pro³

1) Switch on SIRT 2) Select Power

(Yellow LED on) 

Select control panel

3) Check Bluetooth 4) Select Bluetooth in the

is enabled control panel

5) Select Scan All 6) Select SIRT_XXXXXXXX

and pair it

7) Use Passcode 1209 8) Define serial port (take

care that there is no conflict

with other devices)

9) Use your selected COM Port also for SensusREADsoftware for the Sensus RF channel

Pairing with desktop or laptop:

1) Check your computer’s manual for special

requirements installation advice and

compatibility.

2) Check your computer provides Bluetooth radio

(integrated or Bluetooth USB stick).

3) Switch on SIRT.

4) Open your Bluetooth manager and scan for

Bluetooth devices.

5) Select the SIRT and pair it with the password

“1209”.

6) Check which COM port is used.

7) Use this COM port also in SensusREAD.

Page 23: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 23/28

Sensus Interface Radio Tool (SIRT433)Manual

MS 2511 INT SIRT, page [email protected]

Charging battery (general):Charging process starts only, when SIRT is switchedon; yellow LED. To charge the battery use the USBcable (part of delivery). Before 1st usage battery ischarged around 50% only and SIRT must becharged completely.Red LED for “Charge” will be switched on, whencharging starts.Charging stops and red LED is switched offautomatically, when battery is full or batterytemperature is above 40 °C or below 0 °C.

Charging via a computer:1) Computer is switched on and OS is started.

2) Connect the USB cable to your computer.3) Required time to charge an empty battery is

around 8h (while SIRT is switched on).

4) Take care that your computer will not be

switched off or enter Sleep Mode.

Charging via a mains power supply (part of

delivery):

1) Connect your power supply with mains power

or 12V car cigarette lighter.

2) Required time to charge an empty battery is

around 4h.

Note: The lifetime of a rechargeable battery isusually around 2 years. In case the working time of afully charged battery is decreased dramatically itmust be changed. Due to safety reasons it is notallowed to open SIRT housing and to use any otherbattery. Send SIRT back to a Sensus store frontoffice and order the battery change

Using external antenna:

1) Screw the aerial on the magnetic foot.2) Check for a good position of the magnet foot

on top of your car roof.

3) Make sure that the antenna is securely fixed

on top of the roof and connects to the roof’s

metal only.

4) Keep magnet foot clean and take care your

roof’s paintwork will not be damaged.

5) Connect the antenna cable with the aerial and

lead it to the car’s interior. Avoid squeezing

the cable in the car’s door or window. Cable

can be damaged and radio performance

drops. Keep cable length outside the car as

short as possible.

6) Be sure SIRT is switched off; yellow LED is

off.

7) Connect the antenna cable with SIRT antenna

plug.

8) Lead the antenna cable and fix SIRT in the car

in a way it will not distract your attention from

driving and traffic. Use the backside clip to fix

SIRT on the empty front-seat passenger’s

safety belt or find another safe position.

9) Always drive carefully and not faster than

50km/h or 30mph and follow any speed limits.

10) The user is responsible for a safe usage of the

equipment. If it is not possible to use the

equipment under traffic conditions safely, you

have to stop your car before you are allowed

to read a radio endpoint. You may not

configure or handle the SIRT while driving.

Note: Before starting communication via the externalantenna, make sure the antenna is really connectedwith SIRT. Radio communication via externalantenna plug without the antenna connected candamage or weaken the radio electronics!Use only Sensus accessories, including withoutlimitation Sensus external antenna with order no.04410537. Using other accessories or externalantennas is not in accordance with the radioapproval (see technical data) and can damage theradio. It is not allowed to use any other devices,

accessories or other parts that are not explicitlyallowed by Sensus.

Don’t use the external antenna if it is windy or evenduring thunderstorm conditions or if such weather isforecast.External antenna application is only for drive-byoperation. The external antenna is not recommendedto use while wearing SIRT on the belt.

The user has to ensure the correct fixing of theexternal antenna and is responsible for such. Sensusis not responsible for any harm caused by anincorrect fixing or operation, or any other incorrect

usage of the external antenna.

Using SIRT with other software:Without license agreement it is not allowed to useSIRT with other software applications thanSensusREAD.On demand you can get software DLL to integrateSensus RF reading in your own application inaccordance with the respective license agreement

Technical data:

Frequency 433 MHzPower TX 10 mW radio endpoints,

1 mW Wake up radio endpointsafter installation

Modulation 2-GFSK

SupportedProtocols

Sensus radio protocol RX/TX

Dimensions 95 x 145 x 35Weight 295gBluetooth

USBWater proofExternal

 Antenna cable

Typicalduration ofusage with afully chargedbattery

Class II Interface

Version 2.0IP53 (without vacuum)

3,0m

12h

 ApprovalsRadio frequency: R&TTE Directive 99/5/EGCE declaration: www.sensus.comRoHS compliant

Environment conditionsOperation: min. -18 °C / max + 60 °CStorage: min -20 °C / max + 60 °CCharging battery: min. 0 °C / max. 40 °C

Never use or switch on SIRT in an aircraft, insi dea petrol station or similar environment requiringEX proof.

Note: You must not leave the SIRT in the car in frontof the windows in the sun. Also after a fast change oftemperature there is a risk of humid condensation on

the inner electronic board. Switching on SIRTunder this condition without a break time coulddamage the electronics.

 Any visible and valuable items left in a car mayattract thieves. Please make sure your SIRT or

any accessory does not get stolen.

Disposal:

This product contains a LithiumIon rechargeable battery.In the interest of protecting theenvironment, this battery may notbe disposed in household wasteafter its period of use.The local and nationalregulations for environmentalprotection are to be considered

Page 24: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 24/28

The data interface and flexiblepulse output for Bulk Water Meters

www.sensus.com

HRI-Mei

Special Features

Compatible to bulk water meters with MeiStream and MeiTwin MID standard

register

Load-free inductive scanning of the meter’s pointer

Retrofitable

Detection of water flow direction

Electronic pulse output means no switch bouncing

Pulse-weight, mode and length can be changed on site

Self diagnostic and tamper detection

Battery lifetime up to 12 years. With external power supply i.e. a M-Bus

central unit lifetime can be expanded

Sealed housing (IP68)

Cable length 3 m

Description

The HRI-Mei is a data capture device for MeiStream

an MeiTwin MID bulk water meters. All MeiStream

standard registers are prepared to receive the HRI-

Mei.

The HRI-Mei can also be mounted afterwards

without breaking the meter’s seal.

The HRI-Mei provides a high resolution pulse

output with water flow direction detection.

Also the data interface can be used for M-Bus

applications or for MiniBus devices like MiniPad or

Sensus((S))cout-MB

With the HRI-Mei all known data interfaces with

Encoder, Electronic and Hybrid registers can be

replaced.

Depending on the register a second pulser like the

Opto OD can be plugged in additionally e.g. at the

MeiStream.

Also other applications requiring reed switches or

optical pulse outputs can be supported with only

this one data capture device.

Page 25: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 25/28LS8400INT  Page 2

Applications 

Meter reading based for billing purposes i.e.

mobile reading systems.

Meter remote reading and profiling via cable fixed

networks with M-Bus, radio modem or GSM

network.

Industrial control applications with the FM-1D/K or

FM-2D/K

Data logging in conjunction with various data

loggers; i.e. CDL.

Logging and transfer of flow profiles in conjunction

with XENON internet access.

Robust design allows the use of the HRI-Mei in

harsh environments like flooded pits.

Page 26: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 26/28

HRI-Mei

LS8400INT  Page 3

Pulse Modes

The HRI-Mei provides 7 different pulse output modes via 2 lines.

Parallel usage of the pulse output and serial output is not recommended andmay cause problems depending on the application.

Mode B1:

is used for remote pulse collectors with only one pulse input.

I1: balanced pulses (*)

I2: alarm (**)

(*) Backward pulses are compensated by suppressing the same quantity offorward pulses

(**)  alarms can be programmed for broken pipe, leakage, tampering, cable cutand indicated by ground level at the output.

Mode B2:

I1: Forward pulses

I2: Backward pulses

Mode B3:

I1: For-/Backward pulses

I2: signal for the flow direction (*)

(*) Ground level means reverse flow

Mode B4 (default):

as mode B1,but line I2 is inverted

Mode B5:

Opto-OD (NAMUR) pulse output (6 ms)

I1: pulses with flow direction code

I2: not used

Mode B6:NAMUR (as OD-AM) pulse output (7 ms)

I1: balanced pulses as mode B1

I2: not used

Mode B7:

Dual pulse output

I1: balanced pulses as mode B1

I2: same as I1

Temperature range:

HRI-Mei standard for cold water (30 °C) and warm water (50 °C).

Environmental temperature range: -10 °C ... +60 °C

Technical Data

cable length 3 m

Pulse output

According to pulse mode

Opto-OD (NAMUR) compatible:

programmable pulse weights

(10, 25,....1000) litre/pulse

Pulse length 6ms

NAMUR acc. EN 60947-5-6

Reed-RD compatible:

programmable pulse weights

(10, 25,....10000) litre/pulse

Pulse length 32, 128 or 500ms

max. Voltage 48 Vdc

max. current 0,2 A

max. switching capacity 4 W

Data interface

M-Bus and MiniBus (autodetected)

Autom. detection of baud rate (300/2400Bd) andtype of interface.

Data protocol according IEC870-5/EN1434-3

An Encoder mode provides an easy to use dataprotocol compatible to the encoder registers.

Transferred Data 

Meter index

Fabrication number

Meter ID. equivalent to secondary address

Monthly meter index for programmable day

Meter index for programmable yearly key date andfor the year before

Min./max. water flow with date/time

Backward water volume with date/timeBroken pipe and leakage detection withprogrammable flow thresholds

Tamper detection (*)

The HRI-Mei can be programmed to transfer

selected information.

Programmable Data

All changeable data can be set with MiniCom

software via the M-Bus / MiniBus data interface.MiniCom download is free of charge from the

Sensus web site.

(*) Requires tamper target at the meter.

Page 27: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 27/28

UK & Ireland Enquiries

Sensus UK Systems Ltd, International House, Southampton International Business Park,George Curl Way, Southampton SO18 2RZ UK

T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com

International EnquiriesSensus GmbH Hannover, Meineckestraße 10, D-30880 Laatzen Germany

T: +49 (0) 5102 74-0 F: +49 (0) 5102 74-3341 Email: [email protected] www.sensus.com

13005 Subject to changes without prior notice.LS8400INT  Page 4

Classical Sensus pulsers and equivalent HRI-Mei mode

Order Information

Previous pulse outputs Litres/pulse

RD01, RD011 10 to 100.000 lpp

OD01, OD03, OD07-L, OD07-24V, OD07-24S 10 to 1.000 lpp

OD AM 10 to 1.000 lpp

OD02/EX(cold), special HRI-Mei variant 10 to 1.000 lpp

10 litre per pulses with 32 ms pulse length only.

All other pulse weights can be set to 500 ms pulse length.For DN150-300 min pulse weight 100 lpp.

HRI-Mei variant

(examples *) Settings Application Order no.

HRI-Mei/B1/D10/T500/50 °CPulse Mode 1 (open collector)Pulse weight 100 lppPulse length 500ms

Cold water for DN40....125 MEI1ACG2XX

HRI-Mei/B1D1/T32/50 °CPulse Mode 1 (open collector)Pulse weight 10 lppPulse length 32ms

Cold water for DN40....125 MEI1AAD2XX

HRI-Mei/B5/D1/T6/50 °CPulse Mode 5 (Namur)Pulse weight 10 lppPulse length 6ms

Cold water for DN40....125 MEI1EDD2XX

HRI-Mei-CDL/D1/50 °CPulse Mode 2Pulse weight 10 lppWith CDL plug

CDL data logging

Cold water for DN40....125MEI3XXD2XX

HRI-Mei/B1/D10/T500/50 °CPulse Mode 1 (open collector)Pulse weight 1000 lppPulse length 500ms

Cold water for DN 150.....300 MEI1ACK3XX

HRI-Mei/B1D1/T32/50 °CPulse Mode 1 (open collector),Pulse weight 100 lpp,Pulse length 32ms

Cold water for DN 150...300 MEI1AAG3XX

HRI-Mei/B5/D1/T6/50 °CPulse Mode 5 (Namur)Pulse weight 100 lppPulse length 6ms

Cold water for DN 150.....300 MEI1EDG3XX

HRI-Mei-CDL/D1/50 °CPulse Mode 2Pulse weight 100 lppWith CDL plug

CDL data logging

Cold water for DN 150.....300MEI3XXG3XX

**Further variants on request.

Pulse value 10 50 100 250 500

Pulse length 32 128 500 32 128 500 32 128 500 32 128 500 32 128 500

10 l

pointer

40 DN x x - x x x x x x x x x x x x

50 DN x x - x x x x x x x x x x x x

65 DN x x - x x x x x x x x x x x x

80 DN x - - x x x x x x x x x x x x100 DN x - - x x - x x x x x x x x x

125 DN x - x x - x x x x x x x x x

100 l

pointer

150 DN not possible x x - x x x x x x

200 DN not possible x x - x x x x x x

250 DN not possible x x - x x - x x x

300 DN not possible x - - x x - x x x

Possible pulse values

Certified according to ISO 9001

Quality Management System Quality Austria Reg.no. 3496/0

Page 28: Sensus Product Brochure v7 (May 2015)

8/19/2019 Sensus Product Brochure v7 (May 2015)

http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 28/28

Sensus UK Systems Ltd

3 Lindenwood

Crockford Lane

Chineham Business Park

Basingstoke,

RG24 8QY  UK

+44 20 7112 1565

[email protected]