Sensitivity of Human Lymphocytes to Sensitivity of Human Lymphocytes to Low-Dose RadiationLow-Dose Radiation
Gordon K. Livingston, PhDGordon K. Livingston, PhD
Technical Director, Cytogenetic Biodosimetry LaboratoryTechnical Director, Cytogenetic Biodosimetry Laboratory
Radiation Emergency Assistance Center Training SiteRadiation Emergency Assistance Center Training Site
Oak Ridge Insitute for Science and EducationOak Ridge Insitute for Science and Education
Oak Ridge, TN 37831Oak Ridge, TN 37831
http://orise.orau.gov/reactshttp://orise.orau.gov/reacts
Cytogenetic BiodosimetryCytogenetic Biodosimetry
Cytogenetic analysis provides a method to estimate radiation dose to individuals exposed to ionizing radiation when
physical dosimetry devices are not available.
LymphocytesLymphocytes
Lymphocytes serve as ideal biological dosimeters because they: 1) are very sensitive to radiation,
2) are readily available in routine blood samples,
3) circulate throughout the body,
4) can be easily cultured and induced to divide in vitro
5) respond consistently to ionizing radiation exposure by expressing chromosomal DNA damage in a dose-dependent manner.
Image of Normal Metaphase Spread
Dicentric ChromosomeDicentric Chromosome
Dicentric Chromosome AssayDicentric Chromosome Assay
Low background rate (1-2 per 1,000 cells) Independent of age and gender Sensitivity range (0.2 – 5 Gy) Specificity to radiation is high Consistent radiation dose-response Proven in accidents over four decades Considered the gold standard
Multiple Dicentric ChromosomesMultiple Dicentric Chromosomes
Typical Dose Response CurvesTypical Dose Response Curves
Y=D+D2
Quadratic (linear-quadratic)
Y=DLinear
Dic
entr
ics/
cell
Dose [Gy]
The Lymphocyte Micronucleus The Lymphocyte Micronucleus Test as a Radiation BiodosimeterTest as a Radiation Biodosimeter
LyLLy
Lymphocyte in Normal Anaphase
Lymphocyte in Abnormal Anaphase
Micronucleus
X-Ray Therapy MachineX-Ray Therapy Machine
X-ray Exposure ConditionsX-ray Exposure Conditions
Westinghouse Orthovoltage Therapy Unit
78 kV, 5 mA, 2mm Al added filtration
output measured at 19.8 cGy/min at 50 cm
30 cm field size with +/- 10 % uniformity
graded doses of 0, 5, 10, 15, 20 & 25 cGy
10 ml media (3-4 x 105 cells/ml) in 25 cm2 culture flasks at 37 C for 72 hr
Micronucleus Dose ResponseMicronucleus Dose Response
The Micronucleus Test as a The Micronucleus Test as a Biological DosimeterBiological Dosimeter
Linear Dose Response to X-rays
y = 2.783 x + 3.714
35.5 = 2.783 x + 3.714
X = 11.4 c Gy
NCRP Dose to red marrow is 0.2 m rad / micro Ci
48,000 micro Ci x 0.2 m rad = 9,600 m rad
= 9.6 rad (9.6 c Gy)
Green 3, 5 & 6
Red 1, 2 & 4
FISH - Total Translocations by Group
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
0 5 10 15 20
subjects
nu
mb
er
of
tota
l tra
ns
loc
ati
on
s p
er
ge
no
me
eq
uiv
ale
nt
pe
r 1
00
0 c
ells
FISH-Exposed; High-Dose Group (n=15)
FISH-Unexposed Controls (n=15)
I-131 Internal Exposure
Partial Body X-ray Exposure
Scoring Dicentrics with New Technologies
80 Slide Feeder
Digital Camera and Images
Automated slide scanning stage.
Automated Cytogenetic Workstation
Digital images are used for scoring chromosomes aberrations
(dicentrics).
Scoring Dicentrics with New Technologies
80 Slide Feeder
Digital Camera and Images
Automated slide scanning stage.
Automated Cytogenetic Workstation
Digital images are used for scoring chromosomes aberrations
(dicentrics).
Cytogenetic BiodosimetryCytogenetic Biodosimetry
Limitations– Large event could overwhelm resources– Labor intensive– Samples require shipment
Advantages– Proven method for dose estimation – Amenable to web-based image scoring– Existing resource of clinical laboratories
Cytogenetic Dosimetry Cytogenetic Dosimetry Capacity WorldwideCapacity Worldwide
Cytogenetic labs and regional networks already
collaborating with WHO:– North-American– Latin American (with IAEA support)– European– Scandinavian– Eastern Europe: RF and Ukraine– Western-Pacific: Japan, S. Korea, Australia
Need to integrate and coordinate these networks globally
Need a clear concept of operations for emergencies and in
"quiet" time to make the most of these labs joint capabilities
ConsortiumConsortium
REAC/TS CBL
Secure Central Server (Access Limited)
Lab in Consortium (Metafer Software)
Satellite Scoring Station (Metafer Software)
Lab in Consortium (Metafer System)
The re-establishment of the REAC/TS-Cytogenetic The re-establishment of the REAC/TS-Cytogenetic Biodosimetry Laboratory, operated by the Oak Biodosimetry Laboratory, operated by the Oak Ridge Institute for Science and Education Ridge Institute for Science and Education (ORISE), was supported by: (ORISE), was supported by:
DOE-NNSA, DOE-NNSA, DOE-EH, and DOE-EH, and Nuclear Regulatory Commission.Nuclear Regulatory Commission.
Establishing a Web-Based International Radiation Establishing a Web-Based International Radiation Cytogenetic Biodosimetry Consortium at REAC/TS is Cytogenetic Biodosimetry Consortium at REAC/TS is
being funded by DOE-NNSA.being funded by DOE-NNSA.
QuestionsQuestions