Senergy Cement-Board Stucco TM Systems 1021100 · senergy ® cement-boardstucco tm system cbs-13...

16
Senergy ® Cement-Board Stucco TM Systems 1021100 TYPICAL DETAILS 1. Cement-Board Stucco 1000 System Design Application (Plan View) 2. Cement-Board Stucco 1000 System Design Application (Isometric View) 3. Cement-Board Stucco 500 System Design Application (Plan View) 4. Cement-Board Stucco 500 System Design Application (Isometric View) 5. Clad Window Jamb (Plan View) 6. Clad Window Head 7. Clad Window Sill 8. Primed Window Head 9. Primed Window Jamb (Plan View) 10. Horizontal Expansion Joint at Floorline Wood Frame Construction 11. Control Joint — Reveal 1 12. Control Joint — Reveal 2 13. Control Joint — Reveal 3 14. Termination at Soffit / Gable End 15. Downspout Application (Plan View) 16. Pipe Penetration 17. Light Fixture 18. Dryer Vent 19. Termination at Foundation 20. Termination at Top of Deck 21. Termination at Bottom of Deck 22. Metal Coping Detail 23. EPS Shape Application 24. Corner Detail (Plan View) 25. Fascia / Soffit 26. Kick-out Flashing

Transcript of Senergy Cement-Board Stucco TM Systems 1021100 · senergy ® cement-boardstucco tm system cbs-13...

Senergy® Cement-BoardStuccoTM Systems 1021100

TYPICAL DETAILS

1. Cement-Board Stucco 1000System Design Application(Plan View)

2. Cement-Board Stucco 1000System Design Application(Isometric View)

3. Cement-Board Stucco 500System Design Application(Plan View)

4. Cement-Board Stucco 500System Design Application(Isometric View)

5. Clad Window Jamb (Plan View)

6. Clad Window Head

7. Clad Window Sill

8. Primed Window Head

9. Primed Window Jamb (Plan View)

10. Horizontal Expansion Joint atFloorline Wood FrameConstruction

11. Control Joint— Reveal 1

12. Control Joint— Reveal 2

13. Control Joint— Reveal 3

14. Termination at Soffit / Gable End

15. Downspout Application(Plan View)

16. Pipe Penetration

17. Light Fixture

18. Dryer Vent

19. Termination at Foundation

20. Termination at Top of Deck

21. Termination at Bottom of Deck

22. Metal Coping Detail

23. EPS Shape Application

24. Corner Detail (Plan View)

25. Fascia / Soffit

26. Kick-out Flashing

11/07

Senergy® Cement-Board StuccoTM System

CBS-01 TYPICAL CEMENT-BOARD STUCCO 1000 SYSTEM DESIGNCBS-01 APPLICATION (PLAN VIEW)

CBS-02 TYPICAL CEMENT-BOARD STUCCO 1000 SYSTEM DESIGNCBS-02 APPLICATION (ISOMETRIC VIEW)

CEMENT BOARD

FRAMING

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SELF-ADHERING MESH TAPE (4" )

FRAMING

SENERGY REINFORCING MESH

CORROSION RESISTANTFASTENERS

SENERGY FINISH COAT

SENERGY BASE COAT

ACCEPTABLE SHEATHING

CEMENT BOARD

ACCEPTABLE SHEATHING

FLASHING OR STARTER TRACK

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY BASE COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

CBS-03 TYPICAL CEMENT-BOARD STUCCO 500 SYSTEM DESIGNCBS-03 APPLICATION (PLAN VIEW)

CBS-04 TYPICAL CEMENT-BOARD STUCCO 500 SYSTEMCBS-03 APPLICATION (ISOMETRIC VIEW)

CEMENT BOARD

FRAMING

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SECONDARY MOISTUREPROTECTION BARRIER

SELF-ADHERING MESH TAPE (4" )

FRAMING

SENERGY REINFORCING MESH

CORROSION RESISTANTFASTENERS

SENERGY FINISH COAT

SENERGY BASE COAT

CEMENT BOARD

FLASHING OR STARTER TRACK

SECONDARY MOISTUREPROTECTION BARRIER

SENERGY BASE COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

Senergy® Cement-Board StuccoTM System

CBS-05 TYPICAL CLAD WINDOW JAMB DETAIL (PLAN VIEW)

CBS-06 TYPICAL CLAD WINDOW HEAD DETAIL

CLAD WINDOW

BOND BREAKER TAPEAND SEALANT

CASING BEAD

MIN. 13 mm (1/2")

FRAMING

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERSHIELD, SENERSHIELD-R,9" SENERFLASH OR SENERWRAP

CLAD WINDOW

DRIP EDGE FLASHINGSET IN SEALANT

CASING BEAD WITH WEEPS

FRAMING

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

CBS-07 TYPICAL CLAD WINDOW SILL DETAIL

CBS-08 TYPICAL PRIMED WINDOW HEAD DETAIL

CLAD WINDOW

BOND BREAKER TAPEAND SEALANT

CASING BEAD

MIN. 13 mm (1/2")

FRAMING

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERSHIELD, SENERSHIELD-R,9" SENERFLASH OR SENERWRAP

PRIMED WINDOW

DRIP EDGE FLASHING SETIN SEALANT

CASING BEAD WITH WEEPS

FRAMING

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

Senergy® Cement-Board StuccoTM System

CBS-10 TYPICAL HORIZONTAL EXPANSION JOINT AT FLOORLINEWOOD FRAME CONSTRUCTION

BACKER ROD AND SEALANT

CASING BEAD

WIDTH BY DESIGN

CBS-09 TYPICAL PRIMED WINDOW JAMB (PLAN VIEW)

PRIMED WINDOW

SEALANT

45 DEGREE TRIM

FRAMING

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERSHIELD, SENERSHIELD-R,9" SENERFLASH OR SENERWRAP

FRAMING

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

9" SENERFLASH OR SENERWRAP

CASING BEAD

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

CBS-11 CONTROL JOINT—REVEAL 1

CBS-12 CONTROL JOINT—REVEAL 2

TRIM ACCESSORY

CEMENT BOARD

ACCEPTABLE SHEATHING

MIN. 6 mm (1/4")

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

NOTE :REFER TO CEMENT-BOARDSTUCCO 500 & 1000 TRIMACCESSORIES PRODUCTBULLETIN #1023352 FORPROPER TRIM ACCESSORYATTACHMENT

VARIES

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

NOTE :REFER TO CEMENT-BOARDSTUCCO 500 & 1000 TRIMACCESSORIES PRODUCTBULLETIN #1023352 FORPROPER TRIM ACCESSORYATTACHMENT

TRIM ACCESSORY

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

Senergy® Cement-Board StuccoTM System

CBS-13 CONTROL JOINT—REVEAL 3

13 mm (1/2")

CBS-14 TYPICAL TERMINATION AT SOFFIT/GABLE END

FRAMING

MIN. 50 mm (2")

ACCEPTABLE SHEATHING

BLOCKING

SOFFIT

TRIM

FRIEZE BOARD

CEMENT BOARD

SENERSHIELD, SENERSHIELD-R OR SECONDARYMOISTURE PROTECTION BARRIER

NOTE :REFER TO CEMENT-BOARDSTUCCO 500 & 1000 TRIMACCESSORIES PRODUCT BUL-LETIN #1023352 FOR PROPERTRIM ACCESSORY ATTACH-MENT

TRIM ACCESSORY

CEMENT BOARD

ACCEPTABLE SHEATHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SEALANT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

CBS-15 TYPICAL DOWNSPOUT APPLICATION (PLAN VIEW)

ACCEPTABLE SHEATHING

DOWNSPOUT

SLEEVE

DOWNSPOUT STRAP

SEALANT

FASTENER SET IN SEALANT

SENERSHIELD, SENERSHIELD-R OR SECONDARYMOISTURE PROTECTION BARRIER

CBS-16 TYPICAL PIPE PENETRATION

ACCEPTABLE SHEATHING

FRAMING

SEALANT AT PERIMETEROF PENETRATION

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

CEMENT BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING

CEMENT BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

CBS-18 TYPICAL DRYER VENT

DRYER VENT

FASTENER SET IN SEALANT

SET FLANGE IN SEALANT

SEALANT AT PERIMETER OFPENETRATION

ACCEPTABLE SHEATHING

FASTENER THROUGHNYLON SLEEVE

SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTIONBARRIER

11/07

Senergy® Cement-Board StuccoTM System

CBS-17 TYPICAL LIGHT FIXTURE

FRAMING

SET FLANGE IN SEALANT

SMALL LIGHT FIXTURE

ACCEPTABLE SHEATHING

CEMENT BOARD

SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTION BARRIER

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

CEMENT BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

CBS-19 TYPICAL TERMINATION AT FOUNDATION

ACCEPTABLE SHEATHING

FRAMING

SEALANT

FLASHING

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

CBS-20 TYPICAL TERMINATION AT TOP OF DECK

FLASHING SET IN SEALANT

JOIST

SEALANT

DECK

FRAMING

ACCEPTABLE SHEATHING

MIN. 25 mm (1")

MIN. 50 mm (2")CEMENT BOARD

FLASHING

SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTION BARRIER

NOTE:TERMINATE SENERGY CEMENT-BOARD STUCCO SYSTEM 203 mm(8") MIN. ABOVE GRADE.

CEMENT BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

CASING BEAD WITH WEEPS

FOUNDATION

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

CASING BEAD WITH WEEPS

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

CBS-22 TYPICAL METAL COPING DETAIL

METAL COPING

FRAMING

ACCEPTABLE SHEATHING

50 mm (2")

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

SEALANT

11/07

Senergy® Cement-Board StuccoTM System

CBS-21 TYPICAL TERMINATION AT BOTTOM OF DECK

FLASHING

JOIST

SEALANT

ACCEPTABLE SHEATHING

50 mm (2")

CEMENT BOARD

FRAMING

SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTION BARRIER

CEMENT BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

50 mm (2")

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING• MESH• SENERGY FINISH COAT

11/07

CBS-23 TYPICAL EPS SHAPE APPLICATION

FRAMING

ACCEPTABLE SHEATHING

SENERGY BASE COAT

EPS AESTHETIC BAND

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

CBS-24 TYPICAL CORNER DETAIL (PLAN VIEW)

FRAMING

2 LAYERS FLEXGUARD 4

ACCEPTABLE SHEATHING

SENERSHIELD,SENERSHIELD-R ORSECONDARY MOISTUREPROTECTION BARRIER

CEMENT BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

MIN. 6:12 SLOPE

CEMENT BOARD

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

11/07

Senergy® Cement-Board StuccoTM System

CBS-25 TYPICAL FASCIA / SOFFIT DETAIL

ACCEPTABLE SHEATHING

CEMENT-BOARD

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

CBS-26 TYPICAL KICK-OUT FLASHING DETAIL

NOTE:• KICK-OUT FLASHING MUST BE ANGLED100˚ MIN. TO ALLOW FOR PROPERDRAINAGE.

• KICK-OUT FLASHING SEAMS MUST BESOLDERED OR SEALED WITHAPPROPRIATE SEALANT.

• TERMINATE SENERGY CEMENT-BOARDSTUCCO 1000 SYSTEM 50 MM (2") MIN.ABOVE ROOF.

STEP FLASHING

BACKER ROD AND SEALANT

ROOF SHINGLES

BUILDING PAPER

DRIP EDGE

KICK-OUT FLASHING

MIN. 100 mm (4")

MIN. 50 mm (2")

ACCEPTABLE SHEATHING

CEMENT-BOARD STUCCO SYSTEM

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER

CEMENT BOARDCASING BEAD

DRAINAGE TRIM ACCESSORY

SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT

FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS

NOTE:

General NotesBASF Wall Systems is an operating unit ofBASF Construction Chemicals, LLC. (hereinafter referred to as “BASF Wall Systems”Thesedetails are presented in good faith by BASFWall Systems and represent typical and/orgeneral conditions. They are offered as a guidefor consideration to assist the designer, specifier,installer and/or owner. The responsibility remainswith the user for the design of any system.For conditions not shown, consult BASFWallSystems for specific recommendations. Consultcurrent Senergy technical bulletins for suchinformation as acceptable sealants, insulationattachment methods, installation of air/weatherbarriers, residential policy, code and testreports, geo-climatic considerations, etc.Installation requirements for sealant (jointsize configuration, primers, bond breakers)shall be in accordance with sealantmanufacturer’s specifications and instructions.

Technical SupportConsult the BASF Wall Systems TechnicalServices Department for specific recommendationsconcerning all other applications. Consult theSenergy website, www.senergy.basf.com, foradditional information about products andsystems and for updated literature.

Residential PolicyOn one and two-family residential framedconstruction, BASF Wall Systems requiresthat the wall system selected be one thatincludes provisions for water drainage.The choices include Senturion® line ofwater drainage EIFS, commercial Senerflex®Channeled Adhesive or Channeled InsulationDesign, Senergy Stucco Wall System, andSenergy Cement-Board StuccoTM Systems.There are no exceptions to this policy. Underno circumstances will BASF Wall Systemswarrant the use of any other system onthis type of construction without expressedwritten authorization from BASF WallSystems [Residential construction usingEIFS on masonry (CMU) or poured concretedoes not require the additional water drainageprovisions described above. Senergy ExteriorSurfacing Systems for insulating concreteforms are also acceptable.] See the SenergyResidential Policy Bulletin for a more detaileddiscussion of this topic. Consult BASF WallSystems Technical Services Department forspecific recommendations concerning all otherapplications. Consult the Senergy website,www.senergy.basf.com for additional informationabout products and systems and for updatedliterature.

DisclaimerThis information and all further technicaladvice are based on BASF Wall Systems’present knowledge and experience. However,BASF assumes no liability for providing suchinformation and advice including the extentto which such information and advice mayrelate to existing third party intellectual propertyrights, especially patent rights. In particular,BASF Wall Systems disclaims any and allCONDITIONS AND WARRANTIES, WHETHEREXPRESS OR IMPLIED, INCLUDING THEIMPLIED WARRANTIES OF FITNESS FOR APARTICULAR PURPOSE OR MERCHANTABILITY.BASF WALL SYSTEMS SHALL NOT BERESPONSIBLE FOR CONSEQUENTIAL, INDIRECTOR INCIDENTAL DAMAGES (INCLUDING LOSSOF PROFITS) OF ANY KIND. BASF Wall Systemsreserves the right to make any changesaccording to technological progress or furtherdevelopments. It is the customer’s responsibilityand obligation to carefully inspect and test anyincoming goods. Performance of the product(s)described herein should be verified by testingand carried out only by qualified experts. It isthe sole responsibility of the customer to carryout and arrange for any such testing. Referenceto trade names used by other companies isneither a recommendation, nor an endorsementof any product and does not imply that similarproducts could not be used.

©2007 BASF Construction Chemicals, LLC.Printed in U.S.A. 12/07

BASF Wall Systems3550 St. Johns Bluff Road SouthJacksonville, FL 32224-2614Phone 800 • 221 • 9255Fax 904 • 996 • 6300www.senergy.basf.com