Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY?...

14
Semi Rigid Ducts Introduction Regulations Changing Building Practices Compliance Ductwork Solutions Key Advantages

Transcript of Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY?...

Page 1: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Semi Rigid Ducts

• Introduction

• Regulations

• Changing Building Practices

• Compliance

• Ductwork Solutions

• Key Advantages

Page 2: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

-10%-18%

-25%

-44%

-100%

2006Minumum

Building Regs

2010Minumum

Building Regs

Code Level 1 Code Level 2 Code Level 3 Code Level 4 Code Level 5 Code Level 6/Zero Carbon

Home

Code for Sustainable HomesCode Levels vs Building Regs

Dwelling Emissions Rate

2006 Minimum BuildingRegs

2010 Minimum BuildingRegs/ Target Emissions Rate

Extra Power Generated and sent back to grid

2010 2013 2016

25%

lower

Increasing Regulation

Page 3: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Regulations are changing

Page 4: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Building practices are changing

Page 5: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Compliance

• Semi Rigid Ducting performance

data is now recognised in SAP via

Appendix Q.

• Considered as ‘equal to’ rigid duct

• Only duct systems that feature on

the SAP Appendix Q website have

been tested and validated

• Initially for MVHR systems, MEV

testing will be completed early next

year

Page 6: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Compliance

2010 DOMESTIC VENTILATION

COMPLIANCE GUIDE

Page 7: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

The Problem…

Page 8: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Installation: • Supplied on a roll, 75mm dia flexible

pipe

• Radial design goes direct to room

• Considerable savings on installation

time

• Compatible with i joist, metal web and

concrete screeds

• Easy to run through narrow gaps

The Solution…SEMI RIGID DUCTING

WHY?

Performance: • Limits noise transmission between

rooms

• High crushability typically up to 16

kN/m2

• Low resistance pipe compared to

flexible

Page 9: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Semi-rigid Duct What is semi-rigid duct?

Semi-rigid duct is a new range of superior ducting developed to

make installation and Building Regulation compliance easier.

Page 10: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Features & Benefits GUARANTEED INSTALLED PERFORMANCE

CRUSH RESISTANT

ADJUSTABLE AIRFLOW REGULATORS

NO SEALANTS REQUIRED

DUST CAPS TO SEAL UNIT DURING CONSTRUCTION

HOMEBUYER CONFIDENCE AND COMFORT LARGE SELECTION DECRETIVE GRILLS

EASY TO CLEAN

QUIETER

EASIER & QUICKER INSTALLATION FLEXIBLE

SUPPLIED ON ROLLS

EASY TO CUT

NO SEALANTS REQUIRED

NO INTERMEDIARY JOINS

PRACTICALITY DUST CAPS TO SEAL UNIT DURING CONSTRUCTION

ADJUSTABLE AIRFLOW REGULATORS

UNIVERSAL INSTALLATION

REDUCED RISK OF LEAK/ FAILURES

Page 11: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Advantages Hygeine:

• Increasingly airtight homes need better

ventilation

• Anti static coating prevents dust build up

• Smooth bore for easy cleaning

• Corrosion and abrasion resistant

• Inspection door in Distribution boxes

System:

• Push to seal fittings ensure Zero leakage

• Virtually maintenance free

• Flexible tube gives freedom of design

• Very low noise transmission between

rooms

Page 12: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

Easier & quicker installation

INSTALLATION IS QUICKER

AND SIMPLER THAN

CONVENTIONAL METHODS

AND ASSISTS WITH

REGULATORY COMPLIANCE.

Page 13: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

13

So, why do this. . . .

Page 14: Semi Rigid Ducts€¦ · •Easy to run through narrow gaps The Solution…SEMI RIGID DUCTING WHY? Performance: •Limits noise transmission between rooms •High crushability typically

14

Questions?