Megan Shober, Nuclear Engineer August 16, 2018 Selenium-75 Radiography Overexposure

Transcript of Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma...

Page 1: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Megan Shober, Nuclear EngineerAugust 16, 2018

Selenium-75 Radiography Overexposure

Page 2: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Abbreviations

• Millimeter (mm)• Curie (Ci)• Roengten (R)• Iridium-192 (Ir-192)• Selenium-75 (Se-75)• Half-value layer (HVL)• QSA (not an abbreviation)

2

Page 3: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Outline

• Overview• Timeline• Causes• Lessons learned

3

Page 4: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Overview

Selenium-75 Iridium-192Half-life 120 days 74 daysGamma energy 66-401 keV 206-612 keVSteel thickness 3-29 mm 12-63 mmHalf-value layer (HVL)(tungsten)

0.8 mm 3.3 mm

Gamma constant(at 1 m per Ci)

0.203 R/hr 0.48 R/hr

4

*Information from QSA Global 880 Series Operating Manual

Page 5: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Overview

• Digital radiography on multi-story boiler during mill outage

• Failed to retract source• Did not use survey meter• Did not hear alarming ratemeter• Held collimator in hands

5

Page 6: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Work Site

6

Page 7: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Work Site

7

4 HVLs (Ir-192)

17 HVLs (Se-75)

Page 8: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Timeline

• Performed radiography• Noticed 100 mR on direct-reading

dosimeter, suspected extremity overexposure

• Notified shift supervisor and RSO• Began dose assessment• Notified State

8

7:45

8:15

8:30

9:00

10:00

Page 9: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Calculate exposure

• Estimated 10 second exposure• 96 Curie selenium-75 source

� =�����

• Initial estimate of 650 rads to hands• Final estimate of 176 rem to each hand

9

Page 10: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Investigation

• All inspectors away at training− No steel-toed boots− No inspection supplies

• Limited access to:− License information− Phone numbers− Procedures− Printer

10

Page 11: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Investigation

• Interview radiographers• Visit jobsite• Refine dose estimates• Determine root cause

11

Page 12: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Root Cause (Licensee)

Used Eight Disciplines analysis and Five Whys.• Crew unfamiliarity• Low readings on survey meter• Radio distraction• Lock indicator

12

Failure to use survey meter*Image from QSA Global 880 Series Operating Manual

Page 13: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Root Cause (State)

In addition, we evaluated:• Lack of knowledge about selenium-75• Digital radiography• Alarming ratemeter

13

Page 14: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Root Cause (State)

• We rejected the licensee’s root cause.• Multiple contributing causes related to the

use of Se-75. • Survey meter provided same information as

lock indicator.

14

Poor technique for moving collimator

Page 15: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Lessons Learned

• Surveys of cameras containing Se-75 mostly measure radiation from the depleted uranium shield.

• Alarming ratemeters only alarm in the uncollimated beam.

• Safety-significance of lock indicator is underappreciated by users and regulators.

• There are no training requirements for new sources or devices.

15

Page 16: Selenium-75 Radiography Overexposure · Selenium-75 Iridium-192 Half-life 120 days 74 days Gamma energy 66-401 keV 206-612 keV Steel thickness 3-29 mm 12-63 mm Half-value layer (HVL)

Lessons Learned

• Keep incident procedure and event reporting contacts in easily accessed location.

• Additional training for on-call staff.− Reporting timeframes for materials incidents− Information gathering (re-enactments)