SEDARCHI 75° CEN TE I STEVEN J. C L T KEY ST … in Progress...LAWNDALE HIGH SCHOOL ACADEMIC...
Transcript of SEDARCHI 75° CEN TE I STEVEN J. C L T KEY ST … in Progress...LAWNDALE HIGH SCHOOL ACADEMIC...
ELEVATOR
DETAILS
A7.51
ELEVATOR ELEVATIONNOT TO SCALE
DT14EL03 01
LADDER DETAIL1/2" = 1'-0"
DT14EL04.dwg
TYPICAL CONTROL PANELNOT TO SCALE
DT14EL05
open
1
2
3
close
alarm stop
3
03CALL BUTTON3" = 1'-0"
DT14EL06
FIRE OR EMERGENCYELEVATOR OPERATION
KEY OFF:NORMAL OPERATION
KEY ON:RECALL ELEVATOR TO THISFLOOR. KEY CAN BEREMOVED IN THIS POSITION.
KEY BY-PASS:OVERRIDES HEAT AND SMOKESENSORS TO ALLOW NORMALELEVATOR OPERATION.
IN CASE OFEMERGENCYDO NOT USEELEVATORS
LANTERN DETAIL3" = 1'-0"
DT14EL07
℄℄
07CAB PLANS & ELEVATIONS1/4" = 1'-0"
DT14EL08
04
09ELEVATOR HEAD
3" = 1'-0"
DT14EL10
ELEVATOR DOOR
& FRAME SEE
DETAIL 7/A7.51
FOR FINISH
SHAFTWALL
FRAMING, SEE PLAN
FOR WALL TYPE
ACOUSTICAL BATT
INSULATION
EXTERIOR
PLASTER
SYSTEM
WATERPROOFING
MEMBRANE
ELEVATOR JAMB
3" = 1'-0"
DT14EL10
1" GYP.BD. LINER
ELEVATOR
SHAFT
UL DESIGN U415
UL DESIGN U415
5/8" TYPE "X"
GYP.BD.
NOTE:
FRAMING AT ELEVATOR DOOR SHALL BE A MINIMUM OF 4" STUDS AND RUNNERS
20 GAUGE
HORIZONTAL PLACEMENT OF LINER PANEL AND C-H STUDS PER UL DESIGN U437
FLANGES OF THE JAMB STRUT MUST BE CONTINUOUSLY BRACED BY SCREW
CONNECTIONS TO THE LINER AND FACE PANELS 12" O.C.
ELEVATOR
SHAFT
SEE DETAIL 10/A7.51 FOR
ADDITIONAL INFORMATION
C-H STUD FOR
HORIZONTAL
PLACEMENT OF LINER
UL DESIGN U415
10
ELEVATOR THRESHOLD3" = 1'-0"
DT14EL11.dwg 11
ELEVATOR DEVICES / SIGNAGE1/2"=1'-0"
DT14EL14
℄
EVACUATION SIGNNOT TO SCALE
DT14EL15
17
19
21
22
23
18
ELEVATOR SHAFT WALL @ INTERIOR3" = 1'-0"
DT14EL17A.dwg 15
Re
visio
nD
ate
Da
te
Su
bm
itta
l
Date
Checked by
Job. No.
De
ve
lo
pe
d fo
r
Co
pyrig
ht 2
01
3C
Scale
Th
is
an
d
all
oth
er
pro
je
ct
do
cu
me
nts
an
d
all
id
ea
s,
ae
sth
etics
an
d
de
sig
ns
in
co
rp
ora
te
d
th
ere
in
a
re
in
stru
me
nts
of
se
rvice
.
All
pro
je
ct
do
cu
me
nts
are
th
e
re
giste
re
d p
ro
pe
rty o
f L
PA
, IN
C. (L
PA
) a
nd ca
nn
ot b
e
la
wfu
lly u
se
d in w
ho
le o
r in p
art fo
r a
ny p
ro
je
ct o
r p
urp
ose
exce
pt a
s d
escrib
ed in th
e co
ntra
ctu
al a
gre
em
en
t b
etw
ee
n
LP
A a
nd C
lie
nt. L
PA
h
ere
by g
ive
s fo
rm
al n
otice
th
at a
ny
su
ch
p
ro
je
ct d
ocu
me
nt u
se
, re
pro
du
ctio
n o
r m
od
ifica
tio
n
(m
isu
se
) is n
ot o
nly u
nla
wfu
l b
ut a
uto
ma
tica
lly b
in
ds a
ll
pa
rtie
s in
vo
lve
d w
ith m
isu
se
to fu
lly in
de
mn
ify a
nd d
efe
nd
LP
A a
nd L
PA
's C
on
su
lta
nts to th
e m
axim
um
le
ga
l e
xte
nt
ag
ain
st
all
lo
sse
s,
de
ma
nd
s,
cla
im
s
or
lia
bilitie
s
arisin
g
dire
ctly o
r in
dire
ctly fro
m p
ro
je
ct d
ocu
me
nt m
isu
se
.
Pro
je
ct d
ocu
me
nts d
escrib
e d
esig
n in
te
nt o
f w
ork a
nd
a
re
no
t a
re
pre
se
nta
tio
n o
f a
s-b
uilt o
r e
xistin
g co
nd
itio
ns. L
PA
an
d
LP
A's
Co
nsu
lta
nts
ma
ke
n
o
re
pre
se
nta
tio
ns
co
nce
rn
in
g
th
e
a
ccu
ra
cy
of
do
cu
me
nts
an
d
are
n
ot
re
sp
on
sib
le
fo
r
an
y
d
iscre
pa
ncie
s
be
tw
ee
n
pro
je
ct
do
cu
me
nts a
nd
th
e e
xistin
g co
nd
itio
ns.
FILE NUMBER:
APPL. #:
FLS
DATE
AC SS
DIV. OF THE STATE ARCHITECT
IDENTIFICATION STAMP
LA
WN
DA
LE
H
IG
H S
CH
OO
L
AC
AD
EM
IC
B
UILD
IN
G C
14
90
1 S
. In
gle
wo
od
A
ve
nu
e
La
wn
da
le
, C
A 9
02
60
CE
NT
IN
EL
A V
AL
LE
Y U
NIO
N H
IG
H S
CH
OO
L D
IS
TR
IC
T
10184.10
07/13/16
10
0%
S
CH
EM
AT
IC
D
ES
IG
N4
/0
5/1
3
50
% D
ES
IG
N D
EV
EL
OP
ME
NT
10
/1
8/1
3
10
0%
D
ES
IG
N D
EV
EL
OP
ME
NT
12
/0
6/1
3
50
% C
ON
ST
RU
CT
IO
N D
OC
UM
EN
TS
02
/2
5/1
4
DS
A S
UB
MIT
TA
L0
4/1
1/1
4
DS
A R
ES
UB
MIT
TA
L1
0/0
9/1
5
DS
A B
AC
KC
HE
CK
07
/1
3/1
6
AD
DE
ND
UM
0
01
04
/2
8/1
7
LPA
AS NOTED
No.
S
T
A
T
E
O
F
CAL
I
F
O
R
N
I
A
L
I
C
E
N
S
E
D
AR
C
H
I
T
E
C
T
REN.
11-30-17
C-32815
STEVEN J.
KEY
FIREPROOFING
FIRE CAULKING
ELEVATOR SHAFT
1 1/2" = 1'-0"
DT14EL18
1 1/2"
CONCRETE
OVER METAL
DECK
CONTINUE GYP. BOARD TO
UNDERSIDE OF STRUCTURE AND
PROVIDE FIRE STOPPING PER J/A8.01
WHERE BEAM DOES NOT INHIBIT
STANDARD INSTALLATION
STEEL BEAM
PER
STRUCTURAL
STAIR
SHAFT
EXTERIOR
CEMENT
PLASTER
SYSTEM
5/8" TYPE "X"
GYP.BD., TYP.
FRAME OUT AROUND BEAM AND
CONTINUE GYP. BD. TO UNDERSIDE OF
STRUCTURE PER J/A8.01 WHERE BEAM
INHIBITS STANDARD INSTALLATION
NOTE:
FOR CONDITION
WHERE SHAFT WALL
HITS STRUCTURAL
MEMBER, SEE 17/A7.51
13
FIRE CAULKING
ELEVATOR SHAFT
1 1/2" = 1'-0"
DT14EL09
1"
SHAFT WALL, SEE
PLAN
CONCRETE
OVER METAL
DECK
5/8" TYPE "X"
GYP.BD.,TYP.
STEEL BEAM
PER
STRUCTURAL
ELEVATOR
SHAFT
ELEVATOR SHAFT
1 1/2" = 1'-0"
DT14EL09
1"
SHAFT WALL, SEE
PLAN
5/8" TYPE "X"
GYP.BD.,TYP.
STEEL BEAM
PER
STRUCTURAL
ELEVATOR
SHAFT
7
5
°
GYP. PANEL CANT
PROVIDE ATTACHMENT
CLIP TO BEAM
SEE DETAIL 17/A7.51 FOR
ADDITIONAL INFORMATION
FIREPROOFING
PER UL # X701
FIREPROOFING
PER UL # N779
GENERAL ELEVATOR NOTESN.T.S.
DT14EL01
” ”
”
14