Secury Module XPSAC5121

4
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 23, 2013 1 Product data sheet Characteristics XPSAC5121 module XPSAC - Emergency stop - 24 V AC DC Main Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSAC Safety module applica- tion For emergency stop and switch monitoring Function of module Emergency stop Switch monitoring Safety level Can reach SILCL 3 conforming to EN/IEC 62061 Can reach PL e/category 4 conforming to EN/ISO 13849-1 Safety reliability data PFHd = 3.56E-9 1/h conforming to EN/IEC 62061 DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 210.4 years conforming to EN/ISO 13849-1 Type of start Unmonitored Connections - terminals Captive screw clamp terminals (2 x 0.5...2 x 1.5 mm²)flexible cable with cable end, with double bezel Captive screw clamp terminals (2 x 0.25...2 x 1 mm²)flexible cable with cable end, without bezel Captive screw clamp terminals (2 x 0.14...2 x 0.75 mm²)solid cable without cable end Captive screw clamp terminals (2 x 0.14...2 x 0.75 mm²)flexible cable without cable end Captive screw clamp terminals (1 x 0.25...1 x 2.5 mm²)flexible cable with cable end, without bezel Captive screw clamp terminals (1 x 0.25...1 x 1.5 mm²)flexible cable with cable end, with bezel Captive screw clamp terminals (1 x 0.14...1 x 2.5 mm²)solid cable without cable end Captive screw clamp terminals (1 x 0.14...1 x 2.5 mm²)flexible cable without cable end Output type Relay instantaneous opening 3 NO, volt-free Number of additional circuits 1 solid state output [Us] rated supply volt- age 24 V DC (- 20...20 %) 24 V AC (- 20...10 %) Complementary Supply frequency 50/60 Hz Power consumption in W <= 1.2 W DC Power consumption in VA <= 2.5 VA AC Control circuit voltage 24 V Breaking capacity C300: 1800 VA, AC-15 (inrush) for relay output C300: 180 VA, AC-15 (holding) for relay output Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output Output thermal current 6 A per relay for relay output [Ith] conventional free air thermal current 10.5 A Associated fuse rating 6 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 4 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 Minimum output current 10 mA for relay output Minimum output voltage 16 V for relay output Response time on input open <= 100 ms [Ui] rated insulation voltage 300 V (degree of pollution: 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1

description

Modulo de seguridad XPSAC5121module XPSAC - Emergency stop - 24 V AC

Transcript of Secury Module XPSAC5121

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

.

Jan 23, 20131

Product data sheetCharacteristics

XPSAC5121module XPSAC - Emergency stop - 24 V ACDC

MainRange of product Preventa Safety automationProduct or componenttype

Preventa safety module

Safety module name XPSACSafety module applica-tion

For emergency stop and switch monitoring

Function of module Emergency stopSwitch monitoring

Safety level Can reach SILCL 3 conforming to EN/IEC 62061Can reach PL e/category 4 conforming to EN/ISO13849-1

Safety reliability data PFHd = 3.56E-9 1/h conforming to EN/IEC 62061DC > 99 % conforming to EN/ISO 13849-1MTTFd = 210.4 years conforming to EN/ISO13849-1

Type of start UnmonitoredConnections - terminals Captive screw clamp terminals (2 x 0.5...2 x 1.5

mm²)flexible cable with cable end, with double bezelCaptive screw clamp terminals (2 x 0.25...2 x 1mm²)flexible cable with cable end, without bezelCaptive screw clamp terminals (2 x 0.14...2 x 0.75mm²)solid cable without cable endCaptive screw clamp terminals (2 x 0.14...2 x 0.75mm²)flexible cable without cable endCaptive screw clamp terminals (1 x 0.25...1 x 2.5mm²)flexible cable with cable end, without bezelCaptive screw clamp terminals (1 x 0.25...1 x 1.5mm²)flexible cable with cable end, with bezelCaptive screw clamp terminals (1 x 0.14...1 x 2.5mm²)solid cable without cable endCaptive screw clamp terminals (1 x 0.14...1 x 2.5mm²)flexible cable without cable end

Output type Relay instantaneous opening 3 NO, volt-freeNumber of additionalcircuits

1 solid state output

[Us] rated supply volt-age

24 V DC (- 20...20 %)24 V AC (- 20...10 %)

ComplementarySupply frequency 50/60 HzPower consumption in W <= 1.2 W DCPower consumption in VA <= 2.5 VA ACControl circuit voltage 24 VBreaking capacity C300: 1800 VA, AC-15 (inrush) for relay output

C300: 180 VA, AC-15 (holding) for relay outputBreaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay outputOutput thermal current 6 A per relay for relay output[Ith] conventional free air thermal current 10.5 AAssociated fuse rating 6 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN

VDE 0660 part 2004 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DINVDE 0660 part 200

Minimum output current 10 mA for relay outputMinimum output voltage 16 V for relay outputResponse time on input open <= 100 ms[Ui] rated insulation voltage 300 V (degree of pollution: 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1

2

[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1Local signalling 2 LEDsCurrent consumption 90 mA at 24 V AC (on power supply)

40 mA at 24 V DC (on power supply)Mounting support 35 mm symmetrical DIN railProduct weight 0.16 kg

EnvironmentStandards EN 1088/ISO 14119

EN 60204-1EN/IEC 60947-5-1EN/ISO 13850

Product certifications CSATÜVUL

IP degree of protection IP40 (enclosure) conforming to EN/IEC 60529IP20 (terminals) conforming to EN/IEC 60529

Ambient air temperature for operation -10...55 °CAmbient air temperature for storage -25...85 °C

3

Product data sheetDimensions Drawings

XPSAC5121

Dimensions

4

Product data sheetConnections and Schema

XPSAC5121

Wiring Diagrams

Refer to the Instruction SheetTo download the instruction sheet, follow below procedure:

1 Click on Download & Documents.2 Click on Instruction sheet.