SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet...

25
SECTION 13700 ACCESS CONTROL SYSTEMS Logo Display hidden notes to specifier by using “Tools”/”Options”/“View”/”Hidden Text”. 1.GENERAL 1.1.SECTION INCLUDES A. Microprocessor-based vehicular gate operator system including power supply, safety devices and accessories for the following application: 1. Residential/Lite-Commercial Slide Gate Operators: a. Fail Safe: Model No. Eagle-1000-FSF. b. Fail Secure: Model No. Eagle-1000-FSC. c. Built-in Battery Back-up / Solar Ready: Model No. Eagle-1000-DC. 2. Commercial Slide Gate Operators: a. Fail Safe: Model No. Eagle-2000-FSF. b. Fail Secure: Model No. Eagle-2000-FSC. c. Fail Secure: Model No. Eagle-2000-1HP. d. Fail Secure: Model No. Eagle-2000-DM. 13700- . 1

Transcript of SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet...

Page 1: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

SECTION 13700

ACCESS CONTROL SYSTEMS

Logo

Display hidden notes to specifier by using “Tools”/”Options”/“View”/”Hidden Text”.

1.GENERAL

1.1.SECTION INCLUDES

A. Microprocessor-based vehicular gate operator system including power supply, safety devices and accessories for the following application:

1. Residential/Lite-Commercial Slide Gate Operators:

a. Fail Safe: Model No. Eagle-1000-FSF.

b. Fail Secure: Model No. Eagle-1000-FSC.

c. Built-in Battery Back-up / Solar Ready: Model No. Eagle-1000-DC.

2. Commercial Slide Gate Operators:

a. Fail Safe: Model No. Eagle-2000-FSF.

b. Fail Secure: Model No. Eagle-2000-FSC.

c. Fail Secure: Model No. Eagle-2000-1HP.

d. Fail Secure: Model No. Eagle-2000-DM.

13700- . 1

Page 2: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

e. Fail Secure: Model No. Eagle-2000-APT.

f. Fail Secure: Model No. Eagle-2000-APT-1.5HP.

g. Fail Secure: Model No. Eagle-2000-APT-DM.

3. Residential/Lite-Commercial Swing Gate Operators:

a. Model No. Eagle-100.

4. Commercial Swing Gate Operators:

a. Model No. Eagle-200.

b. Model No. Eagle-200-1HP.

c. Model No. Eagle-200-DM.

1.2.RELATED SECTIONS

A. Section 02810 - Fencing.

B. Section 03330 – Cast In-Place Concrete.

C. Section 16050 – Basic Electrical Materials and Installation.

1.3.REFERENCES

A. Underwriters' Laboratory (UL):

1. UL 325 - Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems.

2. UL 991 - Standard for Tests for Safety-Related Controls Employing Solid-State Devices.

B. NFPA 70 - National Electrical Code.

13700- . 2

Page 3: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

1.4.SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data sheets on each product to be used, including:

1. Product Data Sheets and system description.

2. Block diagrams.

3. Equipment list.

4. Authorized Dealer Certificate and Certified Training Certificates of installers.

5. Preparation instructions and recommendations.

6. Storage and handling requirements and recommendations.

7. Installation methods.

C. Operation Data: Include two copies of operator manuals.

D. Maintenance Data: Include maintenance and repair procedures.

E. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

1.5.QUALITY ASSURANCE

A. Manufacturer Qualifications: The access control system shall be from a single-source manufacturer that specializes in the manufacture of electric gate operators of the specified type.

B. Installer Qualifications: Installer specializing in access control systems with a minimum of three years experience on systems of similar size and scope and acceptable to the manufacturer.

13700- . 3

Page 4: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

C. System Requirements:

1. Design and installation shall comply with applicable codes.

2. Equipment shall be new, in current production, and a standard product of a manufacture of gate operator equipment.

3. Manufacturer shall guarantee availability of parts for a minimum of ten years from date of purchase.

4. Operators shall be built to and fully comply with Underwriter Laboratories Inc. Standard for Safety – Door, Drapery, Louver and Window Operators and Systems, UL325; and Underwriter Laboratories Inc. Standard for Safety – Testes for Safety-Related Controls Employing Solid-State Devices, UL 991.

5. Safety standards require that multiple external sensors shall be installed that are capable of reversing the gate in either direction according to UL325 and UL991 standards upon sensing an obstruction.

6. Current safety standards require that vehicular gate operators be designed and labeled for specific usage classes. Operators shall be rated for all Class Standards including Class I, Class II, Class III, and Class IV.

1.6.DELIVERY, STORAGE, AND HANDLING

A. Store vehicular gate operator shall be stored upright in manufacturer's unopened packaging and protected from all weather conditions until ready for installation.

1.7.PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's limits.

1.8.WARRANTY

A. Manufacturer’s Warranty: Vehicular Gate Operator shall include factory warranty that all equipment is free from defects in materials and workmanship.

13700- . 4

Page 5: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

1. All models in gate operator series Eagle-1000 & Eagle-100.

a. Standard residential five year warranty.

b. Standard commercial five year warranty.

2. All models in series Eagle-2000, Eagle-2000 APT, Eagle-200.

a. Standard residential seven year warranty.

b. Standard commercial five year warranty.

B. Installation Warranty: Installing Contractor shall guarantee equipment and installation for a period of 12 months.

2.PRODUCTS

2.1.MANUFACTURERS

A. Acceptable Manufacturer: Eagle Access Control Systems, Inc.; 12953 Foothill Blvd., Sylmar, CA 91342. ASD. Toll Free Tel: (800) 708-8848. Tel: (818) 837-7900. Fax: (818) 837-7911. Email: [email protected]. Web: http://www.eagleoperators.com.

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.2.RESIDENTIAL/LITE COMMERCIAL SLIDE GATE OPERATORS

A. Product: Eagle-1000 Series Gate Operators as manufactured by Eagle Access Control Systems, Inc.

1. Fail Safe: Model No. Eagle-1000-FSF (1/2 HP).

a. Motor: 1/2 HP continuous duty AC motor 115 VAC at 5.7 A.

13700- . 5

Page 6: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

b. Maximum slide gate length 22 feet (6700 mm).

c. Maximum gate weight is 500 lbs (225 kg).

d. Manual Release: Fail Safe Model (FSF). Gate operator shall use a fail safe design which allows manual operation of the gate from either inside or out without the use of any tools, keys, or devices. Manual operation of gate shall not result in any injury or damage to gate operator .

e. Gate Operator speed is 12 inches (305 mm) per second.

f. Dimensions: 23 inches H by 15-1/2 inches W by 16-1/2 inches D (584 mm by 394 mm by 429 mm).

g. Weight: 80 lbs (36 kg).

2. Fail Secure: Model No. Eagle-1000-FSC (1/2 HP).

a. Motor: 1/2 HP continuous duty AC motor 115 VAC at 5.7 A.

b. Maximum slide gate length 22 feet (6700 mm).

c. Maximum gate weight is 500 lbs (225 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

e. Gate Operator speed is 12 inches (305 mm) per second.

f. Dimensions: 23 inches H by 15-1/2 inches W by 16-1/2 inches D (584 mm by 394 mm by 429 mm).

g. Weight: 80 lbs (36 kg).

B. Vehicular Gate Operator:

1. Housing: Weather resistant black polyethylene cover. .

2. Power: Primary reduction and power transfer is provided by heavy-duty worm gear running in a continuous oil bath. .

3. Gear Reducer: Size 50.

4. Chain Drive: #41 Roller Chain, nickel plated, shall be used as pulling medium. Each gate shall come with 20 feet (6 m) of chain.

13700- . 6

Page 7: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

5. No-weld Chain Kit: Each gate operator shall come with chain bracket, chain bolts & hardware for mounting chain.

2.3.COMMERCIAL SLIDE GATE OPERATORS

A. Product: Eagle-2000 Series Gate Operators as manufactured by Eagle Access Control Systems, Inc.

1. Fail Safe: Model No. Eagle-2000-FSF (1/2 HP).

a. Motor: 1/2 HP continuous duty AC motor 115 VAC at 5.7 A.

b. Maximum slide gate length 45 feet (13716 mm).

c. Maximum gate weight 1000 lbs (450 kg).

d. Manual Release: Fail Safe Model (FSF). Gate operator shall use a fail safe design which allows manual operation of the gate from either inside or out without the use of any tools, keys, or devices. Manual operation of gate shall not result in any injury or damage to gate operator .

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 125 lbs (56 kg).

2. Fail Secure: Model No. Eagle-2000-FSC (1/2 HP).

a. Motor: 1/2 HP continuous duty AC motor 115 VAC at 5.7 A.

b. Maximum slide gate length 45 feet (13716 mm).

c. Maximum gate weight 1000 lbs (450 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 125 lbs (56 kg).

3. Fail Secure: Model No. Eagle-2000-1HP (Twin 1/2 HP).

13700- . 7

Page 8: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

a. Motor: 2 x 1/2 HP continuous duty AC motors 115 VAC at 11.4 A. (Both motors power open and close operations).

b. Maximum slide gate length 45 feet (13716 mm).

c. Maximum gate weight 2000 lbs (900 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 150 lbs (68 kg).

4. Fail Secure: Model No. Eagle-2000-DM (Dual 1/2 HP).

a. Motor: 2 x 1/2 HP continuous duty AC motor 115 VAC at 5.7 A. (One motor to open, one motor to close).

b. Maximum slide gate length 45 feet (13716 mm).

c. Maximum gate weight 1000 lbs (450 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 150 lbs (68 kg).

B. Product: Eagle-2000-APT Series Gate Operators as manufactured by Eagle Access Control Systems, Inc.

1. Gate Operator shall be specially designed for commercial purposes such as apartment buildings and public storage facilities. Gate Operator shall be continuous duty and able to handle continuous cycles in high traffic locations.

2. Fail Secure: Model No. Eagle-2000-APT (1 HP).

a. Motor: 1 HP continuous duty AC motor 115 VAC at 10.5 A.

13700- . 8

Page 9: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

b. Maximum slide gate length 50 feet (15240 mm).

c. Maximum gate weight 2000 lbs (900 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 160 lbs (73 kg).

3. Fail Secure: Model No. Eagle-2000-APT-1.5 HP (Twin 3/4 HP).

a. Motor: 2 x 3/4 HP continuous duty AC motors 115 VAC at 16.6 A. (Both motors power open and close operations).

b. Maximum slide gate length 50 feet (15240 mm).

c. Maximum gate weight 2500 lbs (1125 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 175 lbs (79 kg).

4. Fail Secure: Model No. Eagle-2000-APT-DM (Dual 1 HP).

a. Motor: 2 x 1 HP continuous duty AC motor 115 VAC at 10.5 A. (One motor to open, one motor to close).

b. Maximum slide gate length 50 feet (15240 mm).

c. Maximum gate weight 2000 lbs (900 kg).

d. Manual Release: Fail Secure Model (FSC). Gate operator shall use a fail secure design which requires use of a hex hand crank to open gate in cases of power outage. Manual release shall be designed in such a way that no injury or damage occurs to the operator or user in case of power being activated during course of manual operation.

13700- . 9

Page 10: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

e. Dimensions: 27 inches H by 18-1/2 inches W by 19-3/4 inches D (686 mm by 470 mm by 502 mm).

f. Weight: 185 lbs (83 kg).

C. Vehicular Gate Operator:

1. Housing: Weather resistant black polyethylene cover.

2. Gate Operator shall include power switch and two electrical outlets.

3. Power: Primary reduction and power transfer is provided by heavy-duty worm gear running in a continuous oil bath. .

4. Gear Reducer: Size 60.

5. Gear Reducer: Size 70.

6. Chain Drive: #40 Roller Chain, nickel plated, shall be used as pulling medium.

2.4.SLIDE GATE OPERATION

A. System Performance:

1. Vehicular slide gate operators shall be tested for UL325 and UL991 compliance and be listed by a Nationally Recognized Testing Laboratory.

2. Vehicular slide gate is not designed to be used for pedestrian access. Separate pedestrian gates shall be provided when pedestrian traffic is present.

3. Rated for Class Standards I, II, III, & IV.

4. Vehicular Slide Gate Operator System shall use a microprocessor based control board to control all functions of the Operator.

5. Gate Operator shall have audible alarm to alert in case of emergency situation.

B. Processor Control:

1. The Gate Operator shall use a model Eagle Diamond Control Board to control all functions of the operator.

13700- . 10

Page 11: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

2. Control board shall have built in adjustable timer to allow gate to automatically close.

3. Control board shall have built in selectable Delayed Open/Delayed Close feature.

4. Control board shall have ability to communicate in a Master Slave dual operator setup using only 2 wires.

5. Control board shall have Global Inputs, allowing safety devices to be installed on either gate operator in a Master Slave dual operator setup.

6. Control board shall be able to accept parallel devices on inputs to enable a limitless amount of safety devices to be used.

7. Control board shall have built in feature selector with DIP-switches allowing user to customize options and operational settings.

8. Control board shall provide onboard 24V AC output for use with safety devices and other accessories.

9. Control board shall provide onboard 24V DC output for use with safety devices and other accessories.

10. Control board shall have a One Pass feature to help eliminate tailgating.

11. Control board shall have built in selectable Stop-Reverse feature to allow gate to be stopped and re-opened / re-closed while moving.

C. Reversing Detection:

1. Gate operator shall be designed in such a way that if any obstruction is met during the opening or closing cycle the gate operator will automatically reverse the gate.

2. The gate operator control board shall check the entrapment sensing system at every cycle of operation.

3. The gate operator shall be designed that in a Master Slave dual operator system both gate operators will automatically reverse if either operator senses an obstruction.

4. The Enhanced Reversing Detection (ERD) system shall be designed into the gate operator control board so that in event of failure of external safety devices the gate operator will still be able to sense obstruction and reverse independently of external safety devices.

a. The gate operator control board shall have separate ERD adjustable potentiometers to enable fine tuning of ERD settings for both the open

13700- . 11

Page 12: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

and close portions of the cycle to maximize safety in all installations including uphill.

b. The Enhanced Reversing Detection shall monitor the motor current and reverse the gate upon an increase in current draw.

D. Entrapment Protection:

1. Gate operator control board shall have built in entrapment detection.

2. Upon sensing an entrapment (two sequential activations of ERD), gate operator shall stop and activate an internal alarm. Gate operator shall then require manual activation of the reset switch prior to returning to regular operation.

2.5.RESIDENTIAL/LITE COMMERCIAL SWING GATE OPERATORS

A. Product: Eagle-100 Series Gate Operators as manufactured by Eagle Access Control Systems, Inc.

1. Model No. Eagle-100 (1/2 HP).

a. Motor: 1/2 HP continuous duty AC motor 115 VAC at 5.7 A.

b. Maximum gate weight is 600 lbs (270 kg).

c. Maximum swing gate length 18 feet (5486 mm).

d. Manual Release: Quick Release.

e. Dimensions: 27-1/2 inches H by 16 inches W x 18-1/2 inches D (698 mm by 406 mm by 470 mm).

f. Weight: 170 lbs (77 kg).

2. Vehicular Gate Operator:

a. Housing: Weather resistant dark gray polyethylene cover. .

b. Access: Gate operator cover shall have a stainless steel access door to allow easy access to board and limit assemblies for installation and service.

c. Swing Arm: No pinch design.

d. Gate Operator Speed: 18 seconds to 90 degree open.

13700- . 12

Page 13: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

e. Gate Operator shall include power switch and two electrical outlets.

f. Power: Primary reduction and power transfer is provided by heavy-duty worm gear running in a continuous oil bath. .

g. Gear Reducer: Size 40.

h. Gear Reducer: Size 60.

i. Chain Drive: #50 Roller Chain, nickel plated.

j. Drive: Heavy Duty round bar steel arm is used as pulling medium.

2.6.COMMERCIAL SWING GATE OPERATORS

A. Eagle-200 Series Gate Operators as manufactured by Eagle Access Control Systems, Inc.

1. Model No. Eagle-200.

a. Motor: 1/2 HP continuous duty AC motor 115 VAC at 5.7 A.

b. Maximum gate weight is 750 lbs (338 kg).

c. Maximum swing gate length 20 feet (6096).

d. Dimensions: 29-1/2 inches H by 18-1/4 inches W x 22-1/2 inches D (749 mm by 464 mm by 572 mm).

e. Weight: 200 lbs (91 kg).

2. Model No. Eagle-200-DM (1/2 HP Dual Motors).

a. Designed for use in high traffic applications.

b. Motor: 2 x 1/2 HP continuous duty AC motor 115 VAC at 5.7 A. (One motor to open, one motor to close).

c. Maximum gate weight is 750 lbs (338 kg).

d. Maximum swing gate length 20 feet (6096).

e. Dimensions: 29-1/2 inches H by 18-1/4 inches W x 22-1/2 inches D (749 mm by 464 mm by 572 mm).

f. Weight: 220 lbs (100 kg).

3. Model No. Eagle-200-1HP (1 HP).

13700- . 13

Page 14: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

a. Motor: 1 HP continuous duty AC motors 115 VAC at 10.5 A.

b. Maximum gate weight is 1000 lbs (450 kg).

c. Maximum swing gate length 20 feet (6096).

d. Dimensions: 29-1/2 inches H by 18-1/4 inches W x 22-1/2 inches D (749 mm by 464 mm by 572 mm).

e. Weight: 210 lbs (95 kg).

B. Vehicular Gate Operator:

1. Housing: Weather resistant black polyethylene cover. .

2. Access: Gate operator cover shall have a stainless steel access door to allow easy access to board and limit assemblies for installation and service.

3. Swing Arm: No pinch design.

4. Gate Operator Speed: 18 seconds to 90 degree open.

5. Gate Operator shall include power switch and two electrical outlets.

6. Manual Release: Quick Release.

7. Power: Primary reduction and power transfer is provided by heavy-duty worm gear running in a continuous oil bath. .

8. Gear Reducer: Size 40.

9. Gear Reducer: Size 70.

10. Chain Drive: #50 Roller Chain, nickel plated.

11. Drive: Heavy Duty round bar steel arm is used as pulling medium.

2.7.SWING GATE OPERATION

A. System Performance:

1. Vehicular swing gate operators shall be tested for UL325 and UL991 compliance and be listed by a Nationally Recognized Testing Laboratory.

2. Vehicular swing gate is not designed to be used for pedestrian access. Separate pedestrian gates shall be provided when pedestrian traffic is present.

13700- . 14

Page 15: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

3. Rated for Class Standards I, II, III, & IV.

4. Vehicular Swing Gate Operator System shall use a microprocessor based control board to control all functions of the Operator. .

5. Gate Operator shall have audible alarm to alert in case of emergency situation.

6. Gate Operator shall have a release arm in case of power outage. Arm shall have a lever, which when turned disengages the arm from the operator and allows the gate to be opened and closed manually.

7. Gate operator shall be designed so that if power is re-engaged during manual operation no injury or damage shall occur to the user or operator.

B. Processor Control:

1. The Gate Operator shall use a model Eagle Diamond Control Board to control all functions of the operator.

2. Control board shall have built in adjustable timer to allow gate to automatically close.

3. Control board shall have built in selectable Delayed Open/Delayed Close feature.

4. Control board shall have ability to communicate in a Master Slave dual operator setup using only 2 wires.

5. Control board shall have Global Inputs, allowing safety devices to be installed on either gate operator in a Master Slave dual operator setup.

6. Control board shall be able to accept parallel devices on inputs to enable a limitless amount of safety devices to be used.

7. Control board shall have built in feature selector with DIP-switches allowing user to customize options and operational settings.

8. Control board shall provide onboard 24V AC output for use with safety devices and other accessories.

9. Control board shall provide onboard 24V DC output for use with safety devices and other accessories.

10. Control board shall have a One Pass feature to help eliminate tailgating.

11. Control board shall have built in selectable Stop-Reverse feature to allow gate to be stopped and re-opened / re-closed while moving.

13700- . 15

Page 16: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

C. Reversing Detection:

1. Gate operator shall be designed in such a way that if any obstruction is met during the opening or closing cycle the gate operator will automatically reverse the gate.

2. The gate operator control board shall check the entrapment sensing system at every cycle of operation.

3. The gate operator shall be designed that in a Master Slave dual operator system both gate operators will automatically reverse if either operator senses an obstruction.

4. The Enhanced Reversing Detection (ERD) system shall be designed into the gate operator control board so that in event of failure of external safety devices the gate operator will still be able to sense obstruction and reverse independently of external safety devices.

a. The gate operator control board shall have separate ERD adjustable potentiometers to enable fine tuning of ERD settings for both the open and close portions of the cycle to maximize safety in all installations including uphill.

b. The Enhanced Reversing Detection shall monitor the motor current and reverse the gate upon an increase in current draw.

D. Entrapment Protection:

1. Gate operator control board shall have built in entrapment detection.

2. Upon sensing an entrapment (two sequential activations of ERD), gate operator shall stop and activate an internal alarm. Gate operator shall then require manual activation of the reset switch prior to returning to regular operation.

2.8.SAFETY DEVICES AND CONTROL EQUIPMENT

A. Loop Detector: Eagle Plug-in Loop Detector for in ground loop as indicated or required for operation as Reversing/Safety to prevent swing or slide gate from closing on vehicles, Phantom/Shadow to prevent swing gate from closing on vehicles or Exit to automatically open gate. LED indicator panel for diagnostics and operation status. Ground loop from 20 to 1500 uH.

1. Model EG 169.

13700- . 16

Page 17: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

2. Provide saw-cut or direct burial preformed 4 feet by 8 feet (1219 mm by 2438 mm) minimum 40’ lead wire ( Model EG241/EG242) or size as indicated or required.

B. Photo-Eye: Non-contact sensor using beam and reflector to prevent gate from closing on vehicles or persons.

1. Product: Eagle Part No. EG178 Omron Photo Detector.

C. Edge Sensors: Padded contact sensor used to detect any impact and inform gate operator to reverse upon contact with object, comprised of Sensing Edge, Radio Transmitter and Radio Receiver as indicated below.

1. Product: Eagle Part No. EG256 Safety Edge with universal wire position with Eagle Part No. EG260 Safety Edge Radio Transmitter and Eagle Part No. EG136 Radio Receiver.

2. Square Gate Construction: 4 feet (1219 mm) feet.

3. Square Gate Construction: 5 feet (1524 mm) feet.

4. Square Gate Construction: 6 feet (1829 mm) feet.

5. Round Rube Gate Construction: 4 feet (1219 mm) feet.

6. Round Tube Gate Construction: 5 feet (1524 mm) feet.

7. Round Tube Gate Construction: 6 feet (1829 mm) feet.

D. Radio Controls; Receivers:

1. Radio Control Receiver shall work at frequency of 300 and/or 310 MHz and consist.

2. Model: EG128 Standard Single Channel Receiver single-frequency 300 MHz (Multi-Code 1090).

3. Model: EG136 Long Range Single-channel Receiver, dual-frequency 300 & 310 Mhz (Multi-Code 1099-50).

4. Model: EG137 Long Range 2-Channel Receiver, dual-frequency 300 & 310 Mhz (Multi-Code 3028-50).

E. Radio Controls; Transmitters:

13700- . 17

Page 18: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

1. Radio Control Transmitters shall work at frequency of 300 and/or 310 MHz and consist.

2. Model: EG140 Standard One Button/One Channel Transmitter single-frequency 300 MHz (Multi-Code 3089).

3. Model: EG144 Standard Two Button/Two Channel Transmitter single-frequency 300 MHz(Multi-Code 4120).

4. Model: EG148 Standard Four Button/Four Channel Transmitter single-frequency 300 MHz (Multi-Code 4140).

F. Three Button Station:

1. For positive control of Open, Close & Stop function of gate.

2. Model EG186 Three Button Station.

G. 7-Day Electronic Programmable Time:

1. Timer shall provide 6 program per seven day week in which gate can be held open in times of high traffic.

2. Model: EG157 7-Day Programmable Timer.

H. Fire Boxes:

1. Eagle Fire Boxes are made of 14 gauge steel and are powder coated bright red. All boxes are clearly labeled Fire Dept. on both sides. .

2. Model: EG060 Fire Box with Micro Switch Operation (EFB-2000).

3. Model: EG064 Fire Box for Knox Key Switch (EFB-2010).

4. Model: EG068 Fire Box with Chain Release Operation (EFB-2070).

I. Key Switch Lock Boxes:

1. Key Switch Lock Boxes are made of 14 gauge steel, powder coated black with a stainless steel faceplate. Each box has punch-outs for surface or post mounting and comes with 2 keys for each lock.

13700- . 18

Page 19: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

2. Model: EG076 Key Box with Schlage Brand Mortise Cylinder (EFB-2020). Mortise lock can be keyed to the house key and gives momentary contact to open and close the gate.

3. Model: EG080 Key Box for Momentary Contact (EFB-2030). Gives momentary contact to open and close gate, key can removed only in the closed, or off position.

4. Model: EG084 Key Box for Constant Contact (EFB-2040). Gives momentary contact to open, hold open and close gate, the key is removable in either closed/open or on/off position.

2.9.BATTERY BACK-UP SYSTEM

A. The Battery Back-Up System shall enable an Eagle Operator to remain fully functional during power failure to maintain UL325 and UL991 Compliance throughout a power outage.

1. System shall use a microprocessor based control board to control all functions of the system.

2. System shall provide 115 V AC power to gate operator.

3. System shall have at least 70 Amp Hours of battery power, through use of two 12 V DC sealed lead acid batteries.

4. System shall include 12 V DC, 3 Amp trickle charger to maintain battery.

5. System shall not impede or interfere with gate operator systems ERD safety function or any other safety function related with gate operator system.

B. Control Board:

1. System shall use a model Eagle Power Relay Control Board; rev A or later, to control all functions of the system.

2. Control Board shall have connections for all necessary components of battery back-up system including AC power in, AC power out, charger, and power inverter.

3. Control Board shall have selectable feature to determine battery back-up and gate operator system actions in event of battery power loss.

13700- . 19

Page 20: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

C. Product: Model Eagle Power I Battery Back-Up System as manufactured by Eagle Access Control Systems, Inc.

1. Inverter: 900 watt (normal)/1800 watt (surge) AC output power inverter.

2. Input Voltage: 105 – 125 V AC.

3. Output Voltage: 105 – 125 V AC.

4. Output Frequency 50/60 Hz.

5. Output Current: Normal 5 Amp, Surge 9 Amp.

6. Relay power output: 2 Amp.

7. Dimensions: 13 inches H by 19 inches W by 12 inches H (330 mm by 483 mm by 305 mm).

8. Weight: 90 lbs.

D. Product: Model Eagle Power II Battery Back-Up System as manufactured by Eagle Access Control Systems, Inc.

1. Inverter: 2300 watt (normal)/4600 watt (surge) AC output power inverter. .

2. Input Voltage: 105 – 125 V AC.

3. Output Voltage: 105 – 125 V AC .

4. Output Frequency 50/60 Hz.

5. Output Current: Normal 14 Amp, Surge 28 Amp.

6. Relay power output: 10 Amp.

7. Dimensions: 18-1/4 inches H by 24 inches W by 12 inches H (464 mm by 610 mm by 305 mm).

8. Weight: 112 lbs.

2.10.ACCESSORIES

A. Gate Chain:

1. Gate chain to be nickel-plated roller chain and match the size specified by eagle gate operator model.

13700- . 20

Page 21: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

2. Model: XM200 10 feet #41 size nickel-plated roller chain with one master link for all gate operator models in series Eagle-1000.

3. Model: XM208 10 feet #40 size nickel-plated roller chain with one master link for all gate operator models in series Eagle-2000 and Eagle-2000-APT.

B. Uphill Swing Arm:

1. For swinging gate that rises to account for elevation on ground. Up-hill swing arm must fit to Eagle swing gate operator without modification to the quick-release handle. Uphill swing arm to incorporate ball-type connections at each joint in swing arm.

2. Model: XC292 Up-hill Swing Arm for all gate operator models in series Eagle-100 and Eagle-200.

C. Steel Wheels:

1. 4 inches (102 mm) V-Groove Steel Wheels, rated for 3,000 lbs are yellow zinc plated with sealed bearings and Axle Bolt & Nut.

2. 6 inches (152 mm) V-Groove Steel Wheels, rated for 5,000 lbs are yellow zinc plated with sealed bearings and Axle Bolt & Nut.

D. Guide Rollers:

1. Guide rollers are made of UMHW Plastic for non-marring of gate and have sealed bearing and zinc plated brackets for long life. Help reduce friction and assist in a smoother operating gate. 2-1/2 inch (64 mm) diameter roller with approximately 0.25 inch (6 mm) for bracket.

2. Model: EG097 3 inch (76 mm) white.

3. Model: EG103 3 inch (76 mm) black.

4. Model: EG098 6 inch (152 mm) white.

5. Model: EG104 6 inch (152 mm) black.

6. Model: EG102 12 inch (305 mm) white.

7. Model: EG105 12 inch (305 mm) black.

13700- . 21

Page 22: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

E. Freeze Protection Heater: Type 304 stainless steel alloy sheathed tubular heater element protected by a perforated steel sheath.

1. Product: Eagle EG171.

2. Adjustable thermostat. 30 degrees to 150 degrees F (-1 degrees to 66 degrees C).

3. Power Requirement: 125 VAC 250 watts, 2 amps.

4. Size: 8-3/8 inches L by 1-1/2 inches W by 3-1/2 inches H (213 mm by 38 mm by 89 mm).

F. Solar Panels:

1. Assembly includes panel, mounting bracket, 15 feet (4572 mm) lead wire with input clip for control board input.

2. 15 Watt/ 24 VDC. 30 W output power at 1.08 A.

a. Product: Eagle EG515.

3. 20 Watt/ 24 VDC. 40 W output power at 1.25 A.

a. Product: Eagle EG520.

G. Gooseneck Posts/Pedestal:

1. Gooseneck posts have a 90 degree sweep to allow easy access and are powder coated black. The accessory plate is 4 inches by 4 inches (102mm by 102 mm) with 4 slotted 1/4 inch (6 mm) holes for accessory mounting as well as a 2 inches (51 mm) opening for wiring.

2. Model: EG092 Gooseneck Post/Pedestal for Pad Mount installation; 42 inches (1067 mm).

3. Model: EG093 Gooseneck Post/Pedestal for In-ground installation; 72 inches (1829 mm).

3.EXECUTION

3.1.EXAMINATION

13700- . 22

Page 23: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

A. Do not begin installation until substrates have been properly prepared.

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2.PREPARATION

A. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions.

B. Do not proceed with installation until substrates have been properly prepared and deviations from manufacturer's recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions.

C. Clean surfaces thoroughly prior to installation.

D. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3.GATE INSTALLATION

A. Vehicular gate operator shall be installed by a qualified technician with the appropriate experience with similar systems.

B. Wiring shall be in accordance with all applicable codes and manufacturer’s instructions.

13700- . 23

Page 24: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

C. Operator shall be designed to be pad mounted to a concrete pad, firmly secured, and level on all sides.

D. The gate operator is designed to be installed in either a regular front position or a rear mount type installation. Rear mount style installation requires uses of additional Idler Wheel.

E. Wiring shall be in accordance with national electric codes and manufacturer's instructions. Make conduit and wiring connections to existing gate and door hardware devices as required.

F. Install wiring for detection and signal circuit conductors in conduit. Use 22 AWG minimum size conductors.

3.4.BATTERY BACK-UP INSTALLATION

A. System shall be installed by a qualified technician with the appropriate experience with similar systems.

B. System is designed to be wall mounted, firmly secured, and level on all sides.

C. System wiring shall be in accordance with all applicable codes and manufacturer’s instructions.

3.5.SYSTEM INITIALIZATION AND CUSTOMIZATION

A. System shall be turned on and all required adjustments and customizations shall be made to properly activate and fine tune all safety features and options.

B. ERD shall be set to ensure proper levels of settings in case of gate striking object.

13700- . 24

Page 25: SECTION 13700 ACCESS CONTROL SYSTEMS€¦ · 03/07/2016  · b. Maximum slide gate length 22 feet (6700 mm). c. Maximum gate weight is 500 lbs (225 kg). d. Manual Release: Fail Safe

C. System shall function as specified by manufacturer and applicable codes.

3.6.TESTING PROCEDURES

A. System shall be tested completely by contractor including all components, accessories, and safety devices.

B. System shall be demonstrated, including safety devices, in presence of owner or owner’s representative.

3.7.OWNER INSTRUCTIONS AND MANUALS

A. Contractor shall instruct Owner’s representative in use of the system within 30 days of acceptance.

B. Contractor shall instruct Owner’s representative in troubleshooting and service of system within 30 days of acceptance. .

C. Contractor shall provide Owner with copy of owner’s manual. Manual shall include wiring diagrams and drawings of installation.

3.8.PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION.